Annex D Plots of Maximum SAR Test Results

FCC ID: YHLBLUG5PLUS

RF Exposure Info

Download: PDF
FCCID_4299852

   ORLAB,
   '                                                                            REPORT No. : $Z19040180S01


Annex D Plots of Maximum SAR Test Results




           SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                  Tel: 86—755—36898555   Fax: 86—766—36008525
M o RLAB   FL1—3, Building A, FeiYang Science Park, No.8 LongChang Road,
           Block67, BacAn Distrct, ShenZhen , GuangDong Province, P. R. China   Hiteitwvwmortab.on     E—mail: service@morlab.on


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.05


GSMS850_GPRS(2TX slots)_Left Cheek_Ch251


Communication System: UID 0, GSM850(class 10) (0); Frequency: 848.8 MHz;Duty Cycle: 1:4.15
Medium: HSL_835 Medium parameters used: {= 849 MHz; 0 = 0.884 $/m; e = 43.3; p = 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.1 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(9.32, 9.32, 9.32); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch251/Area Sean (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.249 W/kg

Ch251/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=5mm
Reference Value=4.976 V/m; Power Drift=—0.13 dB
Peak SAR (extrapolated) = 0.284 W/kg
SAR(1 g) = 0.234 W/kg: SAR(10 g) = 0.183 W/kg
Maximum value of SAR (measured) = 0.246 W/kg




    —1.90


    —3.80


    ~5.71


    ~1.61


    —9.51
               0 dB =0.249 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.01


GSM1900_GPRS( 3TX slots)_Right Cheek_Ch661


Communication System: UID 0, PCS1900(class 11) (0); Frequency: 1880 MHz;Duty Cycle: 1:2.77
Medium: HSL_1900 Medium parameters used: £= 1880 MHz; a= 1.321 S/m; s = 41.384; p= 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.3 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.68, 7.68, 7.68); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch661/Area Scan (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.0420 Wkg

Ch661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=5mm
Reference Value=1.363 V/m; Power Drift=—0.11 dB
Peak SAR (extrapolated) =0.0650 W/kg
SAR(1 g) = 0.040 W/kg: SAR(10 g) = 0.024 W/kg
Maximum value of SAR (measured) = 0.0428 W/kg




    ~3.05


    —6.10


    ~9.14


    12119


    —15.24
               0 dB =0.0420 We


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.01


WCDMA Band II_RMC 12.2Kbps_Right Cheek_Ch9400


Communication System: UID 0, UMTS—FDD (0); Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: HSL_1900 Medium parameters used: £= 1880 MHz; a= 1.321 S/m; s = 41.384; p= 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.3 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.68, 7.68, 7.68); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch9400/Area Scan (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.355 W/kg

Ch9400/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=2.079 V/m; Power Drift=—0.18 dB
Peak SAR (extrapolated) =0.160 W/kg
SAR(1 g) = 0.077 W/kg: SAR(10 g) = 0.045 W/kg
Maximum value of SAR (measured) = 0.150 Wkg




    ~3.41


    —6.81


    —10.22


    13.62


    —17.03
               0 dB =0.150 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.04.30


WCDMA Band IV_RMC 12.2Kbps_Right Cheek_Ch1312


Communication System: UID 0, UMTS—FDD (0); Frequency: 1712.4 MHz;Duty Cycle: 1:1
Medium: HSL_1800 Medium parameters used: {=1712.4 MHz; a= 1.328 S/m; & = 39.884; p=
1000 kg/m*
Ambient Temperature : 23.2 °C; Liquid Temperature : 224 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.98, 7.98, 7.98); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch1312/Area Sean (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.379 W/kg

Ch1312/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=4.242 V/m; Power Drift= 0.04 dB
Peak SAR (extrapolated) =0.202 W/kg
SAR(1 g) = 0.133 W/kg: SAR(10 g) = 0.080 W/kg
Maximum value of SAR (measured) = 0.150 Wkg




    ~3.36


    —6.71


    10.07


    —13.42


    —16.78
               0 dB =0.379 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.05


WCDMA Band V_RMC 12.2Kbps_Left Cheek_Ch4132



Communication System: UID 0, UMTS—FDD (0); Frequency: 826.4 MHz;Duty Cycle: 1:1
Medium: HSL_835 Medium parameters used: {= 826.4 MHz; a= 0.859 S/m; e = 43.6; p= 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.1 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(9.32, 9.32, 9.32); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch4132/Area Sean (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.134 W/kg

Ch4132/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=3.397 V/m; Power Drift= 0.50 dB
Peak SAR (extrapolated) = 0.155 W/kg
SAR(1 g) = 0.128 W/kg: SAR(10 g) = 0.101 W/kg
Maximum value of SAR (measured) =0.134 W/kg




    —1.81


    —3.62


    ~5.43


    —1.24


    —9.05
               0 dB =0.134 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.01


LTE Band 2 _20MHz_QPSK_1RB_99O0ffset_Right Cheek_Ch18900


Communication System: UID 0, LTE (0); Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: HSL_1900 Medium parameters used: £= 1880 MHz; a= 1.321 S/m; s = 41.384; p= 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.3 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.68, 7.68, 7.68); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch18900/Area Scan (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.0660 Wkg

Ch18900/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=1.614 V/m; Power Drift= 0.08 dB
Peak SAR (extrapolated) =0.0950 W/kg
SAR(1 g) = 0.060 W/kg: SAR(10 g) = 0.037 W/kg
Maximum value of SAR (measured) = 0.0640 W/kg




    —2.91


    —5.82


    —8.73


    <11.64


    —14.55
               0 dB =0.0660 W/kg =—11.80 dBW/kg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.04.30


LTE Band 4_20MHz_QPSK_1RB_49Offset_Right Cheek_Ch20175


Communication System: UID 0, LTE (0); Frequency: 1732.5 MHz;Duty Cycle: 1:1
Medium: HSL_1800 Medium parameters used: £=1732.5 MHz; a= 1.342 S/m; £.= 39.642; p=
1000 kg/m*
Ambient Temperature : 23.2 °C; Liquid Temperature : 224 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.98, 7.98, 7.98); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch20175/Area Scean (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.122 W/kg

Ch20175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=3.786 V/m; Power Drift= 0.09 dB
Peak SAR (extrapolated) =0.167 W/kg
SAR(1 g) = 0.112 W/kg: SAR(10 g) = 0.074 W/kg
Maximum value of SAR (measured) =0.118 Wkg




    —2.90


    —5.79


    —8.69


    —11.58


    —14.48
               0 dB =0.122 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.05


LTE Band 5_10MHz_QPSK_1RB_49Offset_Left Cheek_Ch20525


Communication System: UID 0, LTE (0); Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium: HSL_835 Medium parameters used: {= 836.5 MHz; 0 = 0.871 S/m; e = 43.433; p= 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.1 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(9.32, 9.32, 9.32); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch20525/Area Scan (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.134 W/kg

Ch20525/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=3.483 V/m; Power Drift= 0.04 dB
Peak SAR (extrapolated) = 0.154 W/kg
SAR(1 g) = 0.128 W/kg: SAR(10 g) = 0.099 W/kg
Maximum value of SAR (measured) =0.133 Wkg




    —1.99


    ~3.98


    ~5.98


    —1.97


    —9.96
               0 dB =0.134 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.06


LTE Band 12_10MHz_QPSK_1RB_250ffset_Right Cheek_Ch23130


Communication System: UID 0, LTE (0); Frequency: 711 MHz;Duty Cycle: 1:1
Medium: HSL_750 Medium parameters used: {= 71 1 MHz; 0 = 0.863 $/m; e, = 41.689; p = 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.6 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN7445; ConvF(10.03, 10.03, 10.03); Calibrated: 2018.09.04;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch23130/Area Scan (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.0323 Wkg

Ch23130/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=1.497 V/m; Power Drift= 0.19 dB
Peak SAR (extrapolated) =0.0380 W/kg
SAR(1 g) = 0.031 W/kg: SAR(10 g) = 0.024 W/kg
Maximum value of SAR (measured) =0.0321 W/kg




    —1.75


    —3.51


    ~5.26


    —7.02


    —8.77
               0 dB =0.0323 Whkg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.06


LTE Band 17_10MHz_QPSK_1RB_490ffset_Right Cheek_Ch23790


Communication System: UID 0, LTE (0); Frequency: 710 MHz;Duty Cycle: 1:1
Medium: HSL_750 Medium parameters used: {= 710 MHz; 0 =0.861 $/m; e, = 41.702; p = 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.6 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN7445; ConvF(10.03, 10.03, 10.03); Calibrated: 2018.09.04;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch23790/Area Scan (71x91x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.0349 Wkg

Ch23790/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=1.146 V/m; Power Drift= 0.05 dB
Peak SAR (extrapolated) =0.0410 W/kg
SAR(1 g) = 0.033 W/kg: SAR(10 g) = 0.026 W/kg
Maximum value of SAR (measured) = 0.0346 W/kg




    —1.67


    —3.33


    —5.00


    —6.66


    —8.33
               0 dB =0.0349 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.08


WLAN 2.4GHz_802.11b 1Mbps_Right Cheek_Ch6


Communication System: UID 0, WLAN 2.4GHz 802.11b (0); Frequency: 2437 MHz;Duty Cycle: 1: 1
Medium: HSL_2450 Medium parameters used: £=2437 MHz; 0 = 1.845 S/m; e, = 37.968; p = 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.3 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.34, 7.34, 7.34); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch6/Area Scan (81x101x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 0.135 W/kg

Ch6/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value=4.755 V/m; Power Drift=—0.02 dB
Peak SAR (extrapolated) =0.326 W/kg
SAR(1 g) = 0.132 W/kg: SAR(10 g) = 0.056 W/kg
Maximum value of SAR (measured) = 0.154 W/kg




    ~3.95


    —7.91


    —11.86


    —15.82


    —19.77
               0 dB =0.135 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.01


GSMS850_GPRS(2TX slots)_Back Side_10mm_Ch251


Communication System: UID 0, GSM850(class 10) (0); Frequency: 848.8 MHz;Duty Cycle: 1:4.15
Medium: MSL_835 Medium parameters used: £= 849 MHz; 0 = 0.993 S/m; s = 55.699; p = 1000
kg/m3
Ambient Temperature : 23.1 °C; Liquid Temperature : 22.2 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(9.24, 9.24, 9.24); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch251/Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.398 W/kg

Ch251/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=5mm
Reference Value=16.59 V/m; Power Drift= 0.03 dB
Peak SAR (extrapolated) =0.658 W/kg
SAR(1 g) = 0.395 W/kg:; SAR(10 g) = 0.225 W/kg
Maximum value of SAR (measured) = 0.436 Wkg




    ~2.76


    —5.52


    ~8.27


    —11.03


    —13.79
               0 dB =0.398 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.04.29


GSM1900_GPRS(3TX slots)_Back Side_10mm_Ch661


Communication System: UID 0, PCS1900(class 11) (0); Frequency: 1880 MHz;Duty Cycle: 1:2.77
Medium: MSL_1900 Medium parameters used: £= 1880 MHz; 0 = 1.497 $/m; s = 54.63; p= 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.5 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.4,7.4, 7.4); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch661/Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.342 W/kg

Ch661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=5mm
Reference Value=4.921 V/m; Power Drift=—0.16 dB
Peak SAR (extrapolated) = 0.577 W/kg
SAR(1 g) = 0.330 W/kg: SAR(10 g) = 0.175 W/kg
Maximum value of SAR (measured) =0.372 W/kg




    ~3.22


    —6.44


    ~1.65


    ~12.87


    —16.09
               0 dB =0.342 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.04.29


WCDMA Band II_RMC 12.2Kbps_Back Side_10mm_Ch9400


Communication System: UID 0, UMTS—FDD (0); Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: MSL_1900 Medium parameters used: £= 1880 MHz; 0 = 1.497 $/m; s = 54.63; p= 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.5 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.4,7.4, 7.4); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch9400/Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.553 W/kg

Ch9400/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value= 5.995 V/m; Power Drift=—0.01 dB
Peak SAR (extrapolated) =0.909 W/kg
SAR(1 g) = 0.528 W/kg:; SAR(10 g) = 0.280 W/kg
Maximum value of SAR (measured) = 0.597 W/kg




    ~3.37


    —6.74


    ~10.12


    —13.49


    —16.86
               0 dB =0.553 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.04.29


WCDMA Band IV_RMC 12.2Kbps_Back Side_10mm_Ch1312


Communication System: UID 0, UMTS—FDD (0); Frequency: 1712.4 MHz;Duty Cycle: 1:1
Medium: MSL_1800 Medium parameters used: £=1712.4 MHz; 0 = 1.51 $/m; . = 53.827; p = 1000
kg/m3
Ambient Temperature : 23.3 °C; Liquid Temperature : 22.3 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.65, 7.63, 7.65); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch1312/Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.705 W/kg

Ch1312/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=9.635 V/m; Power Drift= 0.02 dB
Peak SAR (extrapolated) = 1.09 W/kg
SAR(1 g) = 0.674 W/kg:; SAR(10 g) = 0.385 W/kg
Maximum value of SAR (measured) =0.701 Wkg




    ~3.05


    —6.11


    ~9.16


    —12.22


    —15.27
               0 dB =0.705 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.01


WCDMA Band V_RMC 12.2Kbps_Back Side_10mm_Ch4132


Communication System: UID 0, UMTS—FDD (0); Frequency: 826.4 MHz;Duty Cycle: 1:1
Medium: MSL_835 Medium parameters used: £= 826.4 MHz; 0 =0.971 S/m; & = 55.765; p = 1000
kg/m3
Ambient Temperature : 23.1 °C; Liquid Temperature : 22.2 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(9.24, 9.24, 9.24); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch4132/Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.218 W/kg

Ch4132/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=14.33 V/m; Power Drift=—0.01 dB
Peak SAR (extrapolated) =0.253 W/kg
SAR(1 g) = 0.208 W/kg: SAR(10 g) = 0.163 W/kg
Maximum value of SAR (measured) =0.217 Wkg

   dB
   0


    ~1.58


    315


    ~4.73


    —6.30


    —7.88
               0 dB =0.218 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.04.29


LTE Band 2_20MHz_QPSK_1RB_99Offset_Back Side_10mm_Ch18900


Communication System: UID 0, LTE (0); Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: MSL_1900 Medium parameters used: £= 1880 MHz; 0 = 1.497 $/m; s = 54.63; p= 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.5 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.4,7.4, 7.4); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch18900/Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) =0.681 W/kg

Ch18900/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value= 5.813 V/m; Power Drift= 0.04 dB
Peak SAR (extrapolated) = 1.09 W/kg
SAR(1 g) = 0.627 W/kg:; SAR(10 g) = 0.326 W/kg
Maximum value of SAR (measured) =0.712 Wkg




    ~3.74


    —7.47


    <11.21


    14.94


    —18.68
               0 dB =0.681 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.04.29


LTE Band 4_20MHz_QPSK_1RB_49Offset_Back Side_10mm_Ch20175


Communication System: UID 0, LTE (0); Frequency: 1732.5 MHz;Duty Cycle: 1:1
Medium: MSL_1800 Medium parameters used: £=1732.5 MHz; 0 = 1.529 $/m; e = 53.79; p = 1000
kg/m3
Ambient Temperature : 23.3 °C; Liquid Temperature : 22.3 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.65, 7.63, 7.65); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch20175/Area Sean (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.840 W/kg

Ch20175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=9.290 V/m; Power Drift= 0.04 dB
Peak SAR (extrapolated) = 1.20 W/kg
SAR(1 g) = 0.732 W/kg: SAR(10 g) = 0.408 W/kg
Maximum value of SAR (measured) =0.811 Wkg




    ~3.24


    —6.47


    ~§.71


    12.94


    —16.18
               0 dB = 0.840 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.01


LTE Band 5_10MHz_QPSK_1RB_49O0ffset_Back Side_10mm_Ch20525


Communication System: UID 0, LTE (0); Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium: MSL_835 Medium parameters used: £= 836.5 MHz; 0 = 0.982 S/m; £, = 55.79; p = 1000
kg/m3
Ambient Temperature : 23.1 °C; Liquid Temperature : 22.2 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(9.24, 9.24, 9.24); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch20525/Area Sean (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.254 W/kg

Ch20525/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=14.14 V/m; Power Drift= 0.02 dB
Peak SAR (extrapolated) =0.425 W/kg
SAR(1 g) = 0.251 W/kg: SAR(10 g) = 0.144 W/kg
Maximum value of SAR (measured) =0.275 Wkg




    ~2.67


    5.34


    ~8.01


    —10.68


    —13.35
               0 dB =0.254 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.07


LTE Band 12_10MHz_QPSK_1RB_25Offset_Back Side_10mm_Ch23130


Communication System: UID 0, LTE (0); Frequency: 711 MHz;Duty Cycle: 1:1
Medium: MSL_750 Medium parameters used: £= 711 MHz; a=0.935 S/m; s = 54.84; p= 1000
kg/m3
Ambient Temperature : 23.5 °C; Liquid Temperature : 22.2 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN7445; ConvF(10.05, 10.05, 10.05); Calibrated: 2018.09.04;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch23130/Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) =0.117 W/kg

Ch23130/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=11.13 V/m; Power Drift= 0.12 dB
Peak SAR (extrapolated) =0.133 W/kg
SAR(1 g) = 0.112 W/kg; SAR(10 g) = 0.091 W/kg
Maximum value of SAR (measured) =0.117 Wkg




    —1.34


    —2.67


    ~4.01


    ~5.34


    —6.68
               0 dB =0.117 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.07


LTE Band 17_10MHz_QPSK_1RB_49Offset_Back Side_10mm_Ch23790


Communication System: UID 0, LTE (0); Frequency: 710 MHz;Duty Cycle: 1:1
Medium: MSL_750 Medium parameters used: £= 710 MHz; a= 0.933 S/m; s = 54.86; p= 1000
kg/m3
Ambient Temperature : 23.5 °C; Liquid Temperature : 22.2 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN7445; ConvF(10.05, 10.05, 10.05); Calibrated: 2018.09.04;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch23790/Area Sean (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) =0.118 W/kg

Ch23790/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=11.35 V/m; Power Drift=—0.03 dB
Peak SAR (extrapolated) = 0.134 W/kg
SAR(1 g) = 0.114 W/kg; SAR(10 g) = 0.092 W/kg
Maximum value of SAR (measured) =0.118 Wkg




    —1.29


    —2.58


    ~3.86


    ~5.15


    —6.44
               0 dB =0.118 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.08


WLANZ.4GHz_802.11b 1Mbps_Back Side_10mm_Ch6


Communication System: UID 0, WLAN 2.4GHz 802.11b (0); Frequency: 2437 MHz;Duty Cycle: 1: 1
Medium: MSL_2450 Medium parameters used: £=2437 MHz; 0 =2.019 $/m; & = 50.692; p = 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.7 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.15, 7.15, 7.15); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch6/Area Scan (71x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.0222 Wkg

Ch6/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=1.797 V/m; Power Drift=—0.02 dB
Peak SAR (extrapolated) =0.0690 W/kg
SAR(1 g) = 0.025 W/kg:; SAR(10 g) = 0.013 W/kg
Maximum value of SAR (measured) = 0.0244 W/kg




    210


    ~4.21


    ~6.31


    —B.42


    —10.52
               0 dB =0.0222 We


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.01


GSMS850_GPRS(2TX slots)_Back Side_10mm_Ch251


Communication System: UID 0, GSM850(class 10) (0); Frequency: 848.8 MHz;Duty Cycle: 1:4.15
Medium: MSL_835 Medium parameters used: £= 849 MHz; 0 = 0.993 S/m; s = 55.699; p = 1000
kg/m3
Ambient Temperature : 23.1 °C; Liquid Temperature : 22.2 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(9.24, 9.24, 9.24); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch251/Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.398 W/kg

Ch251/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=5mm
Reference Value=16.59 V/m; Power Drift= 0.03 dB
Peak SAR (extrapolated) =0.658 W/kg
SAR(1 g) = 0.395 W/kg:; SAR(10 g) = 0.225 W/kg
Maximum value of SAR (measured) = 0.436 Wkg




    ~2.76


    —5.52


    ~8.27


    —11.03


    —13.79
               0 dB =0.398 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.04.29


GSM1900_GPRS( 3TX slots)_Bottom Side_10mm_Ch661


Communication System: UID 0, PCS1900(class 11) (0); Frequency: 1880 MHz;Duty Cycle: 1:2.77
Medium: MSL_1900 Medium parameters used: £= 1880 MHz; 0 = 1.497 $/m; s = 54.63; p= 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.5 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.4,7.4, 7.4); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch661/Area Scan (41x71x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.410 W/kg

Ch661/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, daz=5mm
Reference Value=15.51 V/m; Power Drift= 0.02 dB
Peak SAR (extrapolated) =0.581 W/kg
SAR(1 g) = 0.340 W/kg: SAR(10 g) = 0.184 W/kg
Maximum value of SAR (measured) = 0.380 W/kg




    ~3.07


    —6.13
                                                           Edn
    ~9.20


    —12.26


    415.33
               0 dB =0.410 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.04.29


WCDMA Band II_RMC 12.2Kbps_Bottom Side_10mm_Ch9400


Communication System: UID 0, UMTS—FDD (0); Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: MSL_1900 Medium parameters used: £= 1880 MHz; 0 = 1.497 $/m; s = 54.63; p= 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.5 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.4,7.4, 7.4); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch9262/Area Sean (41x71x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.710 W/kg

Ch9262/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=17.43 V/m; Power Drift= 0.07 dB
Peak SAR (extrapolated) =0.980 W/kg
SAR(1 g) = 0.573 W/kg: SAR(10 g) = 0.306 W/kg
Maximum value of SAR (measured) = 0.640 W/kg

   dB
   0


    ~3.33


    —6.66


    —10.00


    <13.33


    —16.66
               0 dB =0.710 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.04.29


WCDMA Band IV_RMC 12.2Kbps_Back Side_10mm_Ch1312


Communication System: UID 0, UMTS—FDD (0); Frequency: 1712.4 MHz;Duty Cycle: 1:1
Medium: MSL_1800 Medium parameters used: £=1712.4 MHz; 0 = 1.51 $/m; . = 53.827; p = 1000
kg/m3
Ambient Temperature : 23.3 °C; Liquid Temperature : 22.3 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.65, 7.63, 7.65); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch1312/Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.705 W/kg

Ch1312/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=9.635 V/m; Power Drift= 0.02 dB
Peak SAR (extrapolated) = 1.09 W/kg
SAR(1 g) = 0.674 W/kg:; SAR(10 g) = 0.385 W/kg
Maximum value of SAR (measured) =0.701 Wkg




    ~3.05


    —6.11


    ~9.16


    —12.22


    —15.27
               0 dB =0.705 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.01


WCDMA Band V_RMC 12.2Kbps_Back Side_10mm_Ch4132


Communication System: UID 0, UMTS—FDD (0); Frequency: 826.4 MHz;Duty Cycle: 1:1
Medium: MSL_835 Medium parameters used: £= 826.4 MHz; 0 =0.971 S/m; & = 55.765; p = 1000
kg/m3
Ambient Temperature : 23.1 °C; Liquid Temperature : 22.2 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(9.24, 9.24, 9.24); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch4132/Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.218 W/kg

Ch4132/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=14.33 V/m; Power Drift=—0.01 dB
Peak SAR (extrapolated) =0.253 W/kg
SAR(1 g) = 0.208 W/kg: SAR(10 g) = 0.163 W/kg
Maximum value of SAR (measured) =0.217 Wkg

   dB
   0


    ~1.58


    315


    ~4.73


    —6.30


    —7.88
               0 dB =0.218 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.04.29


LTE Band 2_20MHz_QPSK_1RB_99Offset_Back Side_10mm_Ch18900


Communication System: UID 0, LTE (0); Frequency: 1880 MHz;Duty Cycle: 1:1
Medium: MSL_1900 Medium parameters used: £= 1880 MHz; 0 = 1.497 $/m; s = 54.63; p= 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.5 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.4,7.4, 7.4); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch18900/Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) =0.681 W/kg

Ch18900/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value= 5.813 V/m; Power Drift= 0.04 dB
Peak SAR (extrapolated) = 1.09 W/kg
SAR(1 g) = 0.627 W/kg:; SAR(10 g) = 0.326 W/kg
Maximum value of SAR (measured) =0.712 Wkg




    ~3.74


    —7.47


    <11.21


    14.94


    —18.68
               0 dB =0.681 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.04.29


LTE Band 4_20MHz_QPSK_1RB_49Offset_Back Side_10mm_Ch20175


Communication System: UID 0, LTE (0); Frequency: 1732.5 MHz;Duty Cycle: 1:1
Medium: MSL_1800 Medium parameters used: £=1732.5 MHz; 0 = 1.529 $/m; e = 53.79; p = 1000
kg/m3
Ambient Temperature : 23.3 °C; Liquid Temperature : 22.3 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.65, 7.63, 7.65); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch20175/Area Sean (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.840 W/kg

Ch20175/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=9.290 V/m; Power Drift= 0.04 dB
Peak SAR (extrapolated) = 1.20 W/kg
SAR(1 g) = 0.732 W/kg: SAR(10 g) = 0.408 W/kg
Maximum value of SAR (measured) =0.811 Wkg




    ~3.24


    —6.47


    ~§.71


    12.94


    —16.18
               0 dB = 0.840 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.01


LTE Band 5_10MHz_QPSK_1RB_49O0ffset_Back Side_10mm_Ch20525


Communication System: UID 0, LTE (0); Frequency: 836.5 MHz;Duty Cycle: 1:1
Medium: MSL_835 Medium parameters used: £= 836.5 MHz; 0 = 0.982 S/m; £, = 55.79; p = 1000
kg/m3
Ambient Temperature : 23.1 °C; Liquid Temperature : 22.2 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(9.24, 9.24, 9.24); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 2; Type: QDO0OPA40CC; Serial: TP:1464
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch20525/Area Sean (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.254 W/kg

Ch20525/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=14.14 V/m; Power Drift= 0.02 dB
Peak SAR (extrapolated) =0.425 W/kg
SAR(1 g) = 0.251 W/kg: SAR(10 g) = 0.144 W/kg
Maximum value of SAR (measured) =0.275 Wkg




    ~2.67


    5.34


    ~8.01


    —10.68


    —13.35
               0 dB =0.254 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.07


LTE Band 12_10MHz_QPSK_1RB_25Offset_Back Side_10mm_Ch23130


Communication System: UID 0, LTE (0); Frequency: 711 MHz;Duty Cycle: 1:1
Medium: MSL_750 Medium parameters used: £= 711 MHz; a=0.935 S/m; s = 54.84; p= 1000
kg/m3
Ambient Temperature : 23.5 °C; Liquid Temperature : 22.2 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN7445; ConvF(10.05, 10.05, 10.05); Calibrated: 2018.09.04;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch23130/Area Scan (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) =0.117 W/kg

Ch23130/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=11.13 V/m; Power Drift= 0.12 dB
Peak SAR (extrapolated) =0.133 W/kg
SAR(1 g) = 0.112 W/kg; SAR(10 g) = 0.091 W/kg
Maximum value of SAR (measured) =0.117 Wkg




    —1.34


    —2.67


    ~4.01


    ~5.34


    —6.68
               0 dB =0.117 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.07


LTE Band 17_10MHz_QPSK_1RB_49Offset_Back Side_10mm_Ch23790


Communication System: UID 0, LTE (0); Frequency: 710 MHz;Duty Cycle: 1:1
Medium: MSL_750 Medium parameters used: £= 710 MHz; a= 0.933 S/m; s = 54.86; p= 1000
kg/m3
Ambient Temperature : 23.5 °C; Liquid Temperature : 22.2 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN7445; ConvF(10.05, 10.05, 10.05); Calibrated: 2018.09.04;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch23790/Area Sean (71x131x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) =0.118 W/kg

Ch23790/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=11.35 V/m; Power Drift=—0.03 dB
Peak SAR (extrapolated) = 0.134 W/kg
SAR(1 g) = 0.114 W/kg; SAR(10 g) = 0.092 W/kg
Maximum value of SAR (measured) =0.118 Wkg




    —1.29


    —2.58


    ~3.86


    ~5.15


    —6.44
               0 dB =0.118 Wikg


Test Laboratory: SAR Lab, of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.05.08


WLANZ.4GHz_802.11b 1Mbps_Back Side_10mm_Ch6


Communication System: UID 0, WLAN 2.4GHz 802.11b (0); Frequency: 2437 MHz;Duty Cycle: 1: 1
Medium: MSL_2450 Medium parameters used: £=2437 MHz; 0 =2.019 $/m; & = 50.692; p = 1000
kg/m3
Ambient Temperature : 23.2 °C; Liquid Temperature : 22.7 °C

DASY5 Configuration:
— Probe: EX3DV4 — SN3823; ConvF(7.15, 7.15, 7.15); Calibrated: 2018.11.12;
— Sensor—Surface: 4mm (Mechanical Surface Detection)
— Electronics: DAE4 Sn480; Calibrated: 2018.10.29
— Phantom: SAM 1; Type: QD00OP40CC; Serial: TP:1471
— Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


Ch6/Area Scan (71x121x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 0.0222 Wkg

Ch6/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value=1.797 V/m; Power Drift=—0.02 dB
Peak SAR (extrapolated) =0.0690 W/kg
SAR(1 g) = 0.025 W/kg:; SAR(10 g) = 0.013 W/kg
Maximum value of SAR (measured) = 0.0244 W/kg




    210


    ~4.21


    ~6.31


    —B.42


    —10.52
               0 dB =0.0222 We