Test Report_JBP

FCC ID: YHLBLUG5

Test Report

Download: PDF
FCCID_4292933

                                                                                                  REPORT No.:SZ19020019E01




                                          TEST REPORT

                                 APPLICANT                               : BLU Products, Inc.

                                 PRODUCT NAME                            : Mobile phone

                                 MODEL NAME                              : G5,V5,D701,STUDIO MINI

                                 BRAND NAME                              : BLU

                                 FCC ID                                  : YHLBLUG5

                                 STANDARD(S)                             : 47 CFR Part 15 Subpart B

                                 RECEIPT DATE                            : 2019-03-13

                                 TEST DATE                               : 2019-04-15 to 2019-04-16

                                 ISSUE DATE                              : 2019-05-21




                                                                  Edited by:
                                                                                               Lv Shangrong(Rapporteur)


                                                                  Approved by:
                                                                                               Andy Yeh(Technical Director)



NOTE: This document is issued by MORLAB, the test report shall not be reproduced except in full without prior written permission of the
company. The test results apply only to the particular sample(s) tested and to the specific tests carried out which is available on request for
validation and information confirmed at our website.


 MORLAB
                         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                      Tel: 86-755-36698555   Fax: 86-755-36698525
                         FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China      Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                                Page 1 of 22


                                                                                           REPORT No.:SZ19020019E01


                                                         DIRECTORY
1. Technical Information········································································································ 3
1.1. Applicant and Manufacturer Information····································································· 3
1.2. Equipment Under Test (EUT) Description ··································································· 3
2. Test Results ························································································································ 6
2.1. Applied Reference Documents ····················································································· 6
2.2. EUT Setup and Operating Conditions ·········································································· 7
3. 47 CFR Part 15B Requirements ······················································································· 9
3.1. Conducted Emission ······································································································ 9
3.2. Radiated Disturbance ··································································································· 13
Annex A Test Uncertainty ··································································································· 20
Annex B Testing Laboratory Information ········································································· 21




                                                               Change History
           Version                                  Date                                     Reason for change
              1.0                             2019-04-16                                             First edition
              2.0                             2019-05-21                                   Update the model name




MORLAB
                     SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                     FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                     Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                         Page 2 of 22


                                                                                     REPORT No.:SZ19020019E01

1. Technical Information
Note: Provide by applicant.

1.1. Applicant and Manufacturer Information
 Applicant:                             BLU Products, Inc.
 Applicant Address:                     10814 NW 33rd St # 100 Doral, FL 33172, Doral, Florida, United
                                        States
 Manufacturer:                          BLU Products, Inc.
 Manufacturer Address:                  10814 NW 33rd St # 100 Doral, FL 33172, Doral, Florida, United
                                        States


1.2. Equipment Under Test (EUT) Description

 EUT Type:                             Mobile phone
 Serial No:                            (N/A, marked #1 by test site)
 Hardware Version:                     FS171-MB-V0.1
 Software Version:                     BLU_G0090_V9.0.01.00
 SIM Cards Description:                SIM 1 and SIM 2 is a chipset unit and tested as a single chipset.
                                       The SIM 1 is chosen for test
 Tx Frequency:                         GSM850: 824 MHz ~ 849 MHz
                                       GSM1900: 1850 MHz ~ 1910 MHz
                                       WCDMA Band II: 1850 MHz ~ 1910 MHz
                                       WCDMA Band IV: 1710 MHz ~ 1755 MHz
                                       WCDMA Band V: 824 MHz ~ 849 MHz
                                       LTE Band 2: 1850 MHz ~ 1910 MHz
                                       LTE Band 4: 1710 MHz ~ 1755 MHz
                                       LTE Band 5: 824 MHz ~ 849 MHz
                                       LTE Band 12: 699 MHz ~ 716 MHz
                                       LTE Band 17: 704 MHz ~ 716 MHz
                                       Bluetooth: 2402 MHz ~ 2480 MHz
                                       802.11b/g/n-20MHz: 2412 MHz ~ 2462 MHz
 Rx Frequency:                         GSM850: 869 MHz ~ 894 MHz
                                       GSM1900: 1930 MHz ~ 1990 MHz
                                       WCDMA Band II: 1930 MHz ~ 1990 MHz
                                       WCDMA Band IV: 2110 MHz ~ 2155 MHz
                                       WCDMA Band V: 869 MHz ~ 894 MHz
                                       LTE Band 2: 1930 MHz ~ 1990 MHz
                                       LTE Band 4: 2110 MHz ~ 2155 MHz



MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 3 of 22


      ORLAB}
                                                                                       REPORT No.: $219020019E01
      «w
                                          LTE Band 5: 869 MHz ~ 894 MHz
                                          LTE Band 12: 729 MHz ~ 746 MHz
                                          LTE Band 17: 734 MHz ~ 746 MHz
                                          Bluetooth: 2402 MHz ~ 2480 MHz
                                          802.11b/g/n—20MHz: 2412 MHz ~ 2462 MHz
                                          GPS/GLONASS: 1559 MHz ~ 1610 MHz
                                          FM: 87.5 MHz ~ 108 MHz
  Ancillary Equipment:                    Battery
                                          Brand Name:                       BLU
                                          Model No.:                        ©835846300P
                                          Serial No.:                       (N/A, marked #1 by test site)
                                          Capacity:                         3000mAh
                                          Rated Voltage:                    3.8V
                                          Charge Limit:                     4.35V
                                          AC Adapter
                                          Brand Name:                       BLU
                                          Model No.:                        US—NB—1504
                                          Serial No.:                       (N/A, marked #1 by test site)
                                          Rated Input:                      100—240V ~ 50/60Hz 0.3A
                                          Rated Output:                     SV =1.5A


Note:


 1.   According to the certificate holder, they declared that the models: G5 and V5, D701, STUDIO

      MINI are accordant in both hardware and software. The four models only differ in the models

      name. The main measuring model is G5, only the results for G5 were recorded in this report.


2.    The Mobile phone supports GSM850MHz, 1900MHz, GPRS, EDGE, WCDMA Band II, Band

      IV, Band V, HSDPA, HSUPA, LTE Band 2/4/5/12/17, Bluetooth, WIFI, GPS/GLONASS and FM

      function.


3.    The EUT is equipped with a T—Flash card slot, two SIM card slots and a Micro USB port which

      can be connected to ancillary equipments.


4.    For a more detailed description, please refer to specification or user‘s manual supplied by the




                  SHENZHEN MORLAB COMMUNICATION TECHNOLOGY Co., Ltd.                   Tel: 86—755—36608555    Fax: 86—755—36808525
M o R LA B        FL1—3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block87, BacAn Distrct, ShenZhen , GuangDong Province, P. R. China   Hitp?/wens.mnorlab.on   E—mail: service@morlab.on

                                                                                                                                       Page 4 of 22


                                                                                   REPORT No.:SZ19020019E01

  applicant and/or manufacturer




MORLAB
             SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
             FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
             Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                 Page 5 of 22


                                                                                      REPORT No.:SZ19020019E01

2. Test Results
2.1. Applied Reference Documents
The objective of the report is to perform testing according to 47 CFR Part 15 Subpart B:

         No.   Identity                                                   Document Title
         1     47 CFR Part 15                                             Radio Frequency Devices

Test detailed items/section required by FCC rules and results are as below:

     No.     Section         Description                             Test Date        Test Engineer              Result
     1       15.107          Conducted Emission                      2019.04.16       Wu Zhongwen                PASS
     2       15.109          Radiated Emission                       2019.04.15       Wu Zhongwen                PASS

NOTE: The tests were performed according to the method of measurements prescribed in ANSI
C63.4-2014.




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 6 of 22


                                                                                      REPORT No.:SZ19020019E01

2.2. EUT Setup and Operating Conditions

Frequency range was investigated: Conducted emission test: from 150 KHz to 30 MHz; Radiated
emission test: from 30 MHz to 6000 MHz.

Test Item
Radiated Emission
Mode 1      : EUT + USB Cable + Adapter + Battery + SIM Card + Earphone + Camera + GSM Idle
              + WCDMA Idle + LTE Idle + Bluetooth Idle + WIFI Idle
Mode 2      : EUT + USB Cable + Adapter + Battery + SIM Card + Earphone + MP4 + GSM Idle +
              WCDMA Idle + LTE Idle + Bluetooth Idle + WIFI Idle
Mode 3      : EUT + USB Cable + Adapter + Battery + Earphone + GSM Idle + WCDMA Idle + LTE
              Idle + Bluetooth Idle + WIFI Idle + FM
Mode 4      : EUT + USB Cable + Adapter + Battery + Earphone + GSM Idle + WCDMA Idle + LTE
              Idle + Bluetooth Idle + WIFI Idle + GPS RX
Mode 5      : EUT + USB Cable + Adapter + Battery + Earphone + GSM Idle + WCDMA Idle + LTE
              Idle + Bluetooth Idle + WIFI Idle + GLONASS RX
Mode 6 : EUT + USB Cable + PC + Battery + Earphone + GSM Idle + WCDMA Idle + LTE
          Idle + Bluetooth Idle + WIFI Idle(Transmitting Data)
Conducted Emission
Mode 1      : EUT + USB Cable + Adapter + Battery + SIM Card + Earphone + Camera + GSM Idle
              + WCDMA Idle + LTE Idle + Bluetooth Idle + WIFI Idle
Mode 2      : EUT + USB Cable + Adapter + Battery + SIM Card + Earphone + MP4 + GSM Idle +
              WCDMA Idle + LTE Idle + Bluetooth Idle + WIFI Idle
Mode 3      : EUT + USB Cable + Adapter + Battery + Earphone + GSM Idle + WCDMA Idle + LTE
              Idle + Bluetooth Idle + WIFI Idle + FM
Mode 4      : EUT + USB Cable + Adapter + Battery + Earphone + GSM Idle + WCDMA Idle + LTE
              Idle + Bluetooth Idle + WIFI Idle + GPS RX
Mode 5      : EUT + USB Cable + Adapter + Battery + Earphone + GSM Idle + WCDMA Idle + LTE
              Idle + Bluetooth Idle + WIFI Idle + GLONASS RX
Mode 6 : EUT + USB Cable + PC + Battery + Earphone + GSM Idle + WCDMA Idle + LTE
         Idle + Bluetooth Idle + WIFI Idle(Transmitting Data)
Remark:
The above test mode in boldface (Mode 6) was the worst case of conducted emission, radiated
emission tests; only the test data of these modes was reported.




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 7 of 22


                                                                                     REPORT No.:SZ19020019E01

During the measurement, the environmental conditions were within the listed ranges:

 Temperature (°C):                                                       15 - 35
 Relative Humidity (%):                                                  30 - 60
 Atmospheric Pressure (kPa):                                             86 - 106




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 8 of 22


                                                                                          REPORT No.:SZ19020019E01


3.        47 CFR Part 15B Requirements
3.1. Conducted Emission
3.1.1.    Requirement

According to FCC section 15.107, the radio frequency voltage that is conducted back onto the AC
power line on any frequency within the band 150kHz to 30MHz shall not exceed the limits in the
following table, as measured using a 50µH/50Ω line impedance stabilization network (LISN).

   Frequency range                                                          Conducted Limit (dBµV)
        (MHz)                                            Quasi-peak                                              Average
         0.15 - 0.50                                        66 to 56                                             56 to 46
          0.50 - 5                                               56                                                 46
           5 - 30                                                60                                                 50
     NOTE:
     a) The limit subjects to the Class B digital device.
     b) The lower limit shall apply at the band edges.
     c) The limit decreases linearly with the logarithm of the frequency in the range 0.15 -
     0.50MHz.


3.1.2.    Test Setup

Please refer to Annex A for the photographs of the Test Configuration.




MORLAB
                    SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555    Fax: 86-755-36698525
                    FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                    Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn    E-mail: service@morlab.cn

                                                                                                                                         Page 9 of 22


                                                                                     REPORT No.:SZ19020019E01

The EUT is placed on a 0.8m high insulating table, which stands on the grounded conducting floor,
and keeps 0.4m away from the grounded conducting wall. The EUT is connected to the power
mains through a LISN which provides 50Ω/50µH of coupling impedance for the measuring
instrument. A Pulse Limiter is used to protect the measuring instrument. The factors of the whole
test system are calibrated to correct the reading.

The power strip or extension cord has been investigated to make sure that the LISN integrity in
maintained with respect to the impedance characteristics as prescribed in ANSI C63.4-2014       at
Clause 4.3.


3.1.3.   Test Result

The maximum conducted interference is searched using Peak (PK), Quasi-peak (QP) and Average
(AV) detectors; the emission levels more than the AV and QP limits, and that have narrow margins
from the AV and QP limits will be re-measured with AV and QP detectors. Tests for both L phase
and N phase lines of the power mains connected to the EUT are performed. All test modes are
considered, refer to recorded points and plots below.




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 10 of 22


                                                                                      REPORT No.:SZ19020019E01

A. Test Plot and Suspicious Points:




                                                          (Plot A:L Phase)




        Fre.        Emission Level (dBµV)                                     Limit (dBµV)
 NO.                                                                                                         Power-line            Verdict
       (MHz)        Quai-peak                 Average                Quai-peak        Average
  1    0.1546           53.47                    37.81                    65.75          55.75                                        PASS
  2    0.1906           51.85                    37.60                    64.01          54.01                                        PASS
  3    0.1995           49.48                    35.35                    63.63          53.63                                        PASS
                                                                                                                Line
  4    0.2219           47.05                    33.87                    62.75          52.75                                        PASS
  5    0.5419           41.91                    34.53                    56.00          46.00                                        PASS
  6    0.6952           34.93                    28.97                    56.00          46.00                                        PASS




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                      Page 11 of 22


                                                                                      REPORT No.:SZ19020019E01




                                                         (Plot B: N Phase)




        Fre.        Emission Level (dBµV)                                     Limit (dBµV)
 NO.                                                                                                         Power-line            Verdict
       (MHz)        Quai-peak                 Average                Quai-peak        Average
  1    0.1589           52.86                    35.40                    65.52          55.52                                        PASS
  2    0.1907           49.73                    32.85                    64.01          54.01                                        PASS
  3    0.2578           44.29                    30.97                    61.50          51.50                                        PASS
                                                                                                              Neutral
  4    0.3343           40.95                    27.74                    59.34          49.34                                        PASS
  5    0.5552           42.25                    33.75                    56.00          46.00                                        PASS
  6    1.3245           34.36                    26.99                    56.00          46.00                                        PASS




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                      Page 12 of 22


                                                                                      REPORT No.:SZ19020019E01

3.2. Radiated Disturbance

3.2.1. Requirement

According to FCC section 15.109 (a), the field strength of radiated emissions from unintentional
radiators at a distance of 3 meters shall not exceed the following values:

              Frequency                 Field Strength Limitation at 3m Measurement Dist
             range (MHz)                              (µV/m)                                  (dBµV/m)
              30.0 - 88.0                                100                                  20log 100
             88.0 - 216.0                                150                                  20log 150
            216.0 - 960.0                                200                                  20log 200
             Above 960.0                                 500                                  20log 500

As shown in FCC section 15.35(b), for frequencies above 1000MHz, the field strength limits are
based on average detector. When average radiated emission measurements are specified in this
part, including emission measurements below 1000MHz, there also is a limit on the radio
frequency emissions, as measured using instrumentation with a peak detector function,
corresponding to 20dB above the maximum permitted average limit for the frequency being
investigated unless a different peak emission limit is otherwise specified in the rules.

Note:

1)   The tighter limit shall apply at the boundary between two frequency range.
2)   Limitation expressed in dBµV/m is calculated by 20log Emission Level(µV/m).


3.2.2. Frequency range of measurement

According to 15.33(b)(1), the frequency range of radiated measurement for the EUT is listed in the
following table:




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 13 of 22


      ORLAB,
      v                                                                                    REPORT No.: $Z19020019E01

3.2.3. Test Setup

 1)   For radiated emissions from 30MHz to1GHz




                                                                                     Test Antennae

                                                                                                  Ai
                                                                                     <im ... 4m >e|
                                                                                                   ii
                                                                                                  v




                                                                           Receivere|—| Preamplifiere



2)    For radiated emissions above 1GHz




                                                                                             C
                                                                                     Test Antennae

                                                                                                   Ai
                                                                                     < im ... 4m >ei
                                                                                                    ii
            Tum Table« ToR                                                                         v
                                pruuume




                                                  ons




              = 80cm >




                                                                           Receivere |—| Preamplifiere



                SHENZHEN MORLAB COMMUNICATION TECHNOLOGY Co., Ltd.                         Tel: 86—755—36608555   Fax: 86—766—36008525
M o R LA B      FL1—3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BacAn Distrct, ShenZhen , GuangDong Province, P. R. China         Hitp:Jwwaw.morlab.on   E—mail: service@morlab.on

                                                                                                                                         Page 14 of 22


                                                                                      REPORT No.:SZ19020019E01

The test is performed in a 3m Semi-Anechoic Chamber; the antenna factor, cable loss and so on of
the site (factors) is calculated to correct the reading. The EUT is placed on a 0.8m high insulating
Turn Table, and keeps 3m away from the Test Antenna, which is mounted on a variable-height
antenna master tower.

For the test Antenna:

In the frequency range above 30MHz, Bi-Log Test Antenna (30MHz to 1GHz) and Horn Test
Antenna (above 1GHz) are used. Test Antenna is 3m away from the EUT. Test Antenna height is
varied from 1m to 4m above the ground to determine the maximum value of the field strength. The
emission levels at both horizontal and vertical polarizations should be tested.


3.2.4.   Test Result

The maximum radiated emission is searched using PK, QP and AV detectors; the emission levels
more than the limits, and that have narrow margins from the limits will be re-measured with AV and
QP detectors. Both the vertical and the horizontal polarizations of the Test Antenna are considered
to perform the tests. All test modes are considered, refer to recorded points and plots below.

The amplitude of emissions (6GHz-12.5GHz) which are attenuated more than 20 dB below the
permissible value need not be reported.

Note: All radiated emission tests were performed in X, Y, Z axis direction, and only the worst axis
test condition was recorded in this test report.




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                    Page 15 of 22


                                                                                      REPORT No.:SZ19020019E01




                                         (Plot A: ANT-Vertical,30MHz - 1GHz)




         Fre.              Pk               QP                AV           Limit-PK   Limit-QP           Limit-AV
 No.                                                                                                                     ANT          Verdict
         MHz           dBµV/m           dBµV/m            dBµV/m            dBµV/m    dBµV/m             dBµV/m
 1     34.8549           29.69              N.A.             N.A.              N.A.     40.00                N.A.          V          PASS
 2     43.5936           29.49              N.A.             N.A.              N.A.     40.00                N.A.          V          PASS
 3     70.7808           29.41              N.A.             N.A.              N.A.     40.00                N.A.          V          PASS
 4     178.5586          33.32              N.A.             N.A.              N.A.     43.50                N.A.          V          PASS
 5     271.7718          25.80              N.A.             N.A.              N.A.     46.00                N.A.          V          PASS
 6     479.5596          31.32              N.A.             N.A.              N.A.     46.00                N.A.          V          PASS




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                      Page 16 of 22


                                                                                      REPORT No.:SZ19020019E01




                                        (Plot A: ANT-Vertical,1GHz - 6GHz)




         Fre.              Pk               QP                AV           Limit-PK   Limit-QP           Limit-AV
 No.                                                                                                                     ANT          Verdict
         MHz           dBµV/m           dBµV/m            dBµV/m            dBµV/m    dBµV/m             dBµV/m
 1     1440.2201         34.25              N.A.             N.A.             74.00      N.A.                54.00         V          PASS
 2     2093.0465         35.73              N.A.             N.A.             74.00      N.A.                54.00         V          PASS
 3     2663.3317         39.17              N.A.             N.A.             74.00      N.A.                54.00         V          PASS
 4     3001.0005         39.85              N.A.             N.A.             74.00      N.A.                54.00         V          PASS
 5     3958.9795         40.27              N.A.             N.A.             74.00      N.A.                54.00         V          PASS
 6     5119.5598         40.76              N.A.             N.A.             74.00      N.A.                54.00         V          PASS




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                      Page 17 of 22


                                                                                      REPORT No.:SZ19020019E01




                                      (Plot B:ANT- Horizontal, 30MHz - 1GHz)




         Fre.              Pk               QP                AV           Limit-PK   Limit-QP          Limit-AV
 No.                                                                                                                     ANT          Verdict
         MHz          dBµV/m            dBµV/m           dBµV/m            dBµV/m     dBµV/m             dBµV/m
 1     33.8839           30.93             N.A.             N.A.              N.A.      40.00                N.A.          H          PASS
 2     44.5646           28.13             N.A.             N.A.              N.A.      40.00                N.A.          H          PASS
 3     63.0130           26.07             N.A.             N.A.              N.A.      40.00                N.A.          H          PASS
 4     180.5005          30.63             N.A.             N.A.              N.A.      43.50                N.A.          H          PASS
 5     291.1912          31.83             N.A.             N.A.              N.A.      46.00                N.A.          H          PASS
 6     479.5596          35.29             N.A.             N.A.              N.A.      46.00                N.A.          H          PASS




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                      Page 18 of 22


                                                                                      REPORT No.:SZ19020019E01




                                       (Plot B:ANT- Horizontal, 1GHz - 6GHz)




         Fre.              Pk               QP                AV           Limit-PK   Limit-QP          Limit-AV
 No.                                                                                                                     ANT          Verdict
         MHz          dBµV/m            dBµV/m           dBµV/m            dBµV/m     dBµV/m             dBµV/m
 1     1440.2201         40.17             N.A.             N.A.             74.00       N.A.                54.00         H          PASS
 2     1595.2976         36.01             N.A.             N.A.             74.00       N.A.                54.00         H          PASS
 3     2193.0965         36.15             N.A.             N.A.             74.00       N.A.                54.00         H          PASS
 4     3001.0005         38.06             N.A.             N.A.             74.00       N.A.                54.00         H          PASS
 5     3546.2731         39.20             N.A.             N.A.             74.00       N.A.                54.00         H          PASS
 6     5172.0860         40.58             N.A.             N.A.             74.00       N.A.                54.00         H          PASS




MORLAB
                SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555     Fax: 86-755-36698525
                FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                      Page 19 of 22


                                                                                    REPORT No.:SZ19020019E01

Annex A Test Uncertainty
The uncertainty is calculated using the methods suggested in the "Guide to the Expression of
Uncertainty in Measurement" (GUM) published by ISO.

Uncertainty of Conducted Emission Measurement

 Measuring Uncertainty for 9kHz-150kHz                                                   ±4.1 dB
 a Level of Confidence of 150kHz-30MHz                                                   ±3.7dB
 95%(U=2Uc(y))

Uncertainty of Radiated Emission Measurement

 Measuring Uncertainty for 30MHz-200MHz                                                  ±5.06dB
 a Level of Confidence of 200MHz-1000MHz                                                 ±5.24dB
 95%(U=2Uc(y))             1GHz-6GHz                                                     ±5.18dB
                                      6GHz-18GHz                                         ±5.48dB




MORLAB
              SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
              FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
              Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                  Page 20 of 22


                                                                                     REPORT No.:SZ19020019E01

Annex B Testing Laboratory Information
1. Identification of the Responsible Testing Laboratory

 Laboratory Name:                             Shenzhen Morlab Communications Technology Co., Ltd.
                                              Morlab Laboratory
 Laboratory Address:                          FL.3, Building A, FeiYang Science Park, No.8 LongChang
                                              Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                              Province, P. R. China
 Telephone:                                   +86 755 36698555
 Facsimile:                                   +86 755 36698525

2. Identification of the Responsible Testing Location

                                               Shenzhen Morlab Communications Technology Co., Ltd.
 Name:
                                               Morlab Laboratory
                                               FL.3, Building A, FeiYang Science Park, No.8 LongChang
 Address:                                      Road, Block 67, BaoAn District, ShenZhen, GuangDong
                                               Province, P. R. China

3. Accreditation Certificate

 Accredited Testing                            The FCC designation number is CN1192.
 Laboratory:                                   Test firm registration number is 226174.
                                               (Shenzhen Morlab Communications Technology Co., Ltd.)

4. Test Software Utilized

             Model                                       Version Number                                     Producer
            JS32-RE                                       Version 2.0.2.0                                   Tonscend
        TS+ -[ JS32-CE]                                     Version2.5.0.0                                  Tonscend




MORLAB
               SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
               FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
               Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn

                                                                                                                                   Page 21 of 22


                                                                                             REPORT No.:SZ19020019E01

5. Test Equipments Utilized

  Description           Manufacturer                        Model                       Serial No.           Cal. Date              Due. Date
   MXE EMI
                              Agilent                      N9038A                  MY54130016               2018.08.04             2019.08.03
   Receiver
  Test Receiver                 R&S                          ESPI                        101052             2018.08.04             2019.08.03
      LISN               Schwarzbeck                    NSLK 8127                        812744             2018.05.08             2019.05.07
  Pulse Limiter
                               VTSD                         9561D                         9537              2018.05.08             2019.05.07
     (20dB)
 Test Antenna -
                         Schwarzbeck                    VULB 9163                       9163-519            2018.05.08             2019.05.07
     Bi-Log
 Test Antenna -
                         Schwarzbeck                  BBHA 9120D                          1774              2018.05.18             2019.05.17
      Horn
   Radiated
                                                      S020180L320
  Disturbance                  rflight                                             61171/61172              2018.07.12             2019.07.11
                                                           3
  Preamplifier
   Radiated
                                                      S10M100L38
  Disturbance                  rflight                                                   46732              2018.07.12             2019.07.11
                                                          02
  Preamplifier
 Semi-Anechoic
                                CRT                     9m*6m*6m                           N/A              2017.01.12             2020.01.11
   Chamber
                                                                                   C02FQ2PYD
       PC                      Apple                        A1370                                                   N/A                   N/A
                                                                                      DQW


                                                          END OF REPORT




MORLAB
                  SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                        Tel: 86-755-36698555     Fax: 86-755-36698525
                  FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
                  Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China        Http://www.morlab.cn     E-mail: service@morlab.cn

                                                                                                                                             Page 22 of 22



Document Created: 2019-06-02 05:37:28
Document Modified: 2019-06-02 05:37:28

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC