Annex C Plots

FCC ID: YHLBLUG5

RF Exposure Info

Download: PDF
FCCID_4253731

                                                                                  REPORT No.:SZ19020019S01



Annex C Plots of System Performance Check




         SHENZHEN MORLAB COMMUNICATIONS TECHNOLOGY Co., Ltd.                   Tel: 86-755-36698555   Fax: 86-755-36698525
MORLAB   FL1-3, Building A, FeiYang Science Park, No.8 LongChang Road,
         Block67, BaoAn District, ShenZhen , GuangDong Province, P. R. China   Http://www.morlab.cn   E-mail: service@morlab.cn


Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.03.26

System Check_750MHz_Head_190326



Communication System: UID 0, CW (0); Frequency: 750 MHz;Duty Cycle: 1:1
Medium: HSL_750 Medium parameters used: f = 750 MHz; σ = 0.885 S/m; εr = 40.809; ρ =
1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.5 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN7445; ConvF(10.03, 10.03, 10.03); Calibrated: 2018.09.04;
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn480; Calibrated: 2018.10.29
- Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


CW 750/Area Scan (81x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 2.11 W/kg

CW 750/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm,
dz=5mm
Reference Value = 49.18 V/m; Power Drift = 0.11 dB
Peak SAR (extrapolated) = 2.83 W/kg
SAR(1 g) = 2.12 W/kg; SAR(10 g) = 1.45 W/kg
Maximum value of SAR (measured) = 2.02 W/kg




               0 dB = 2.02 W/kg


Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.03.26

System Check_835MHz_Head_190326



Communication System: UID 0, CW (0); Frequency: 835 MHz;Duty Cycle: 1:1
Medium: HSl_835 Medium parameters used: f = 835 MHz; σ = 0.902 S/m; εr = 40.935; ρ = 1000
kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.5 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3823; ConvF(9.32, 9.32, 9.32); Calibrated: 2018.11.12;
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn480; Calibrated: 2018.10.29
- Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


CW835/Area Scan (81x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 2.51 W/kg

CW835/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 52.96 V/m; Power Drift = -0.01 dB
Peak SAR (extrapolated) = 3.38 W/kg
SAR(1 g) = 2.28 W/kg; SAR(10 g) = 1.5 W/kg
Maximum value of SAR (measured) = 2.45 W/kg




               0 dB = 2.45 W/kg


Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.03.27

System Check_1750MHz_Head_190327



Communication System: UID 0, CW (0); Frequency: 1750 MHz;Duty Cycle: 1:1
Medium: HSL_1750 Medium parameters used: f = 1750 MHz; σ = 1.391 S/m; εr = 40.358; ρ
= 1000 kg/m3
Ambient Temperature:23.1 ℃; Liquid Temperature:22.2 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3823; ConvF(7.98, 7.98, 7.98); Calibrated: 2018.11.12;
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn480; Calibrated: 2018.10.29
- Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


CW 1750/Area Scan (81x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 10.5 W/kg

CW 1750/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 87.16 V/m; Power Drift = -0.03 dB
Peak SAR (extrapolated) = 16.75 W/kg
SAR(1 g) = 9.24 W/kg; SAR(10 g) = 4.92 W/kg
Maximum value of SAR (measured) = 10.4 W/kg




               0 dB = 10.4 W/kg


Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.03.27

System Check_1900MHz_Head_190327



Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1
Medium: HSL_1900 Medium parameters used: f = 1900 MHz; σ = 1.452 S/m; εr = 40.908; ρ
= 1000 kg/m3
Ambient Temperature:23.1 ℃; Liquid Temperature:22.2 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3823; ConvF(7.68, 7.68, 7.68); Calibrated: 2018.11.12;
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn480; Calibrated: 2018.10.29
- Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


CW 1900/Area Scan (81x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 11.32 W/kg

CW 1900/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 87.56 V/m; Power Drift = 0.11 dB
Peak SAR (extrapolated) = 17.7 W/kg
SAR(1 g) = 9.98 W/kg; SAR(10 g) = 5.32 W/kg
Maximum value of SAR (measured) = 11.2 W/kg




               0 dB = 11.2 W/kg


Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.03.27

System Check_2450MHz_Head_190327



Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: HSL_2450 Medium parameters used: f = 2450 MHz; σ = 1.731 S/m; εr = 37.302; ρ
= 1000 kg/m3
Ambient Temperature:23.5 ℃; Liquid Temperature:22.3 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3823; ConvF(7.34, 7.34, 7.34); Calibrated: 2018.11.12;
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn480; Calibrated: 2018.10.29
- Phantom: SAM 2; Type: QD000P40CC; Serial: TP:1464
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


CW2450/Area Scan (71x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 15.92 W/kg

CW2450/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 88.71 V/m; Power Drift = 0.05 dB
Peak SAR (extrapolated) = 27.4 W/kg
SAR(1 g) = 12.72 W/kg; SAR(10 g) = 6.01 W/kg
Maximum value of SAR (measured) = 14.22 W/kg




               0 dB = 14.22 W/kg


Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.03.24

System Check_750MHz_Body_190324



Communication System: UID 0, CW (0); Frequency: 750 MHz;Duty Cycle: 1:1
Medium: MSL_750 Medium parameters used: f = 750 MHz; σ = 0.965 S/m; εr = 54.221; ρ =
1000 kg/m3
Ambient Temperature:22.9 ℃; Liquid Temperature:22.1 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN7445; ConvF(10.05, 10.05, 10.05); Calibrated: 2018.09.04;
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn480; Calibrated: 2018.10.29
- Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


CW 750/Area Scan (81x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 4.21 W/kg

CW 750/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 66.3 V/m; Power Drift = 0.14 dB
Peak SAR (extrapolated) = 5.87 W/kg
SAR(1 g) = 2.22 W/kg; SAR(10 g) = 1.41 W/kg
Maximum value of SAR (measured) = 4.21 W/kg




               0 dB = 4.21 W/kg


Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.03.24

System Check_835MHz_Body_190324



Communication System: UID 0, CW (0); Frequency: 835 MHz;Duty Cycle: 1:1
Medium: MSL_835 Medium parameters used: f = 835 MHz; σ = 0.981 S/m; εr = 54.351; ρ =
1000 kg/m3
Ambient Temperature:22.9 ℃; Liquid Temperature:22.1 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3823; ConvF(9.24, 9.24, 9.24); Calibrated: 2018.11.12;
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn480; Calibrated: 2018.10.29
- Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


CW 835/Area Scan (81x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 3.95 W/kg

CW 835/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 69.85 V/m; Power Drift = 0.12 dB
Peak SAR (extrapolated) = 5.00 W/kg
SAR(1 g) = 2.51 W/kg; SAR(10 g) = 1.6 W/kg
Maximum value of SAR (measured) = 4.01 W/kg




               0 dB = 4.01 W/kg


Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.03.23

System Check_1750MHz_Body_190323



Communication System: UID 0, CW (0); Frequency: 1750 MHz;Duty Cycle: 1:1
Medium: MSL_1750 Medium parameters used: f = 1750 MHz; σ = 1.446 S/m; εr = 54.718; ρ
= 1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.4 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3823; ConvF(7.65, 7.65, 7.65); Calibrated: 2018.11.12;
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn480; Calibrated: 2018.10.29
- Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


CW 1750/Area Scan (81x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 10.62 W/kg

CW 1750/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 85.75 V/m; Power Drift = 0.12 dB
Peak SAR (extrapolated) = 16.9 W/kg
SAR(1 g) = 9.36 W/kg; SAR(10 g) = 4.93 W/kg
Maximum value of SAR (measured) = 10.5 W/kg




               0 dB = 10.5 W/kg


Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.03.23

System Check_1900MHz_Body_190323



Communication System: UID 0, CW (0); Frequency: 1900 MHz;Duty Cycle: 1:1
Medium: MSL_1900 Medium parameters used: f = 1900 MHz; σ = 1.52 S/m; εr = 53.565; ρ
= 1000 kg/m3
Ambient Temperature:23.3 ℃; Liquid Temperature:22.4 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3823; ConvF(7.4, 7.4, 7.4); Calibrated: 2018.11.12;
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn480; Calibrated: 2018.10.29
- Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


CW 1900/Area Scan (81x81x1): Interpolated grid: dx=1.500 mm, dy=1.500 mm
Maximum value of SAR (interpolated) = 11.14 W/kg

CW 1900/Zoom Scan (5x5x7)/Cube 0: Measurement grid: dx=8mm, dy=8mm, dz=5mm
Reference Value = 79.1 V/m; Power Drift = 0.10 dB
Peak SAR (extrapolated) = 17.9 W/kg
SAR(1 g) = 9.84 W/kg; SAR(10 g) = 5.12 W/kg
Maximum value of SAR (measured) = 11.12 W/kg




               0 dB = 11.12 W/kg


Test Laboratory: SAR Lab. of Shenzhen Morlab Communications Technology Co., Ltd.   Date: 2019.03.26

System Check_2450MHz_Body_190326



Communication System: UID 0, CW (0); Frequency: 2450 MHz;Duty Cycle: 1:1
Medium: MSL_2450 Medium parameters used: f = 2450 MHz; σ = 1.924 S/m; εr = 50.987; ρ
= 1000 kg/m3
Ambient Temperature:23.4 ℃; Liquid Temperature:22.5 ℃

DASY5 Configuration:
- Probe: EX3DV4 - SN3823; ConvF(7.15, 7.15, 7.15); Calibrated: 2018.11.12;
- Sensor-Surface: 4mm (Mechanical Surface Detection)
- Electronics: DAE4 Sn480; Calibrated: 2018.10.29
- Phantom: SAM 1; Type: QD000P40CC; Serial: TP:1471
- Measurement SW: DASY52, Version 52.8 (8); SEMCAD X Version 14.6.10 (7331)


CW 2450/Area Scan (101x101x1): Interpolated grid: dx=1.200 mm, dy=1.200 mm
Maximum value of SAR (interpolated) = 14.52 W/kg

CW 2450/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 86.59 V/m; Power Drift = 0.08 dB
Peak SAR (extrapolated) = 26.8 W/kg
SAR(1 g) = 12.72 W/kg; SAR(10 g) = 5.81 W/kg
Maximum value of SAR (measured) = 14.52 W/kg




               0 dB = 14.52 W/kg