Test Report.pdf

FCC ID: YESWFPS1

Test Report

Download: PDF
FCCID_2903814

                                                                                                                Test Report
                      Curtis-Straus LLC, a wholly owned subsidiary of BV CPS



                 Report No               EP2678-1

                        Client           Powercast Corporation
                                         Charles Greene

                    Address              566 Alpha Drive,
                                         Pittsburgh, PA 15238

                       Phone             412-436-4077

             Items tested                Water Pressure Sensor
                 FCC ID                  YESWFPS1
                    IC ID                8985A-WFPS1
                     FRN                 0019814789

      Equipment Type                     Part 15.247 Digitally Modulated, Mobile
      Equipment Code                     DTS


   FCC/IC Rule Parts                     47 CFR 15.247, RSS-247 Issue 1

                Test Dates               September 16 to 28, 2015 and January 27, 2016

                     Results             As detailed within this report



             Prepared by
                                             Jason Haley– Test Engineer



           Authorized by

                                             Christopher Reynolds – EMC Supervisor


                Issue Date                   01/29/2016


  Conditions of Issue                    This Test Report is issued subject to the conditions stated in the ‘Conditions of Testing’
                                         section on page 24 of this report.



Curtis-Straus LLC is accredited by the American Association for Laboratory Accreditation for the specific scope of accreditation under
Certificate Number 1627-01. This report may contain data which is not covered by the A2LA accreditation.
                           ____________________________________________________________
                Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828
                                                                                                                                         page 1 of 25


                       Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
               ______________________________________________________________________




Contents

 Contents .................................................................................................................................. 2
 Summary ................................................................................................................................. 3
 Test Methodology .................................................................................................................... 4
 Product Tested - Configuration Documentation ....................................................................... 5
   Statement of Conformity ...................................................................................................... 6
 Modifications Required for Compliance ................................................................................... 6
 Test Results ............................................................................................................................ 7
   Bandwidth ............................................................................................................................ 7
   Fundamental Emission Output Power ................................................................................ 10
   Band Edge Measurements ................................................................................................. 13
   Radiated Spurious Emissions ............................................................................................ 14
   Power Spectral Density ...................................................................................................... 17
   Occupied Bandwidth .......................................................................................................... 20
 Measurement Uncertainty...................................................................................................... 23
 Conditions Of Testing ............................................................................................................ 24


                                                                                                                  Form Final Report REV 12-07-15




                       ____________________________________________________________
             Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
             One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                           page 2 of 25


                       Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
               ______________________________________________________________________



Summary
This test report supports an application for certification of a transmitter operating pursuant to 47
CFR 15.247 and RSS-247. The product is the WFPS-1 Water Pressure Sensor. It is a
transmitter that operates in the range 2402-2480MHz.


We found that the product met the above requirements without modifications. Nobody from
Powercast Corporation was present during the testing. The test sample was received in good
condition.




Release Control Record
 Issue No.      Reason for change                 Date Issued
     1         Original Release                   February 12, 2016
                     _____________________________________________________________
             Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
             One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828
                                                                                                            page 3 of 25


                      Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
              ______________________________________________________________________



Test Methodology
Radiated emissions testing was performed according to DTS guidance document 558074D01
v03r04 specified in FCC guidance for performing compliance measurements on DTS devices
under section 15.247, April 19, 2013, and ANSI C63.10 (2013), and RSS-GEN. Radiated
Emissions were maximized by rotating the device around three orthogonal axes as well as
varying the test antenna’s height and polarity. The device antenna cannot be maximized
separately.


Conducted emission at the antenna port was not performed, because the EUT has a non-
removable integrated antenna. All measurements were made using radiated methods.


AC Mains Conducted Emissions testing was not performed as the EUT is battery powered.


The environmental conditions are shown below.

            Date                                   Temperature                                     Humidity
          09/16/15                                22.5 degrees C                                   50% RH
          09/17/15                                22.3 degrees C                                   52% RH
          09/18/15                                23.3 degrees C                                   53% RH
          09/21/15                                 22 degrees C                                    50% RH

The following bandwidths were used during radiated spurious emissions.
          Frequency                        RBW                                                           VBW
         30-1000MHz                       120kHz                                                         1MHz
           1-25GHz                         1MHz                                                          3MHz




                  _____________________________________________________________
          Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
          One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828          page 4 of 25


                           Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
                   ______________________________________________________________________



Product Tested - Configuration Documentation


                                                                        EUT Configuration
           Work Order:        P2678
             Company:         Powercast Corporation
       Company Address:       566 Alpha Drive
                              Pittsburgh, PA, 15238

                   Contact:   Charlie Greene

                                                 MN                                           PN                                       SN
                   EUT:                        WFPS-1                                          --                                    Sample 1
         EUT Description:     Water Pressure Sensor
       EUT Tx Frequency:      2402-2480 MHz

    Port Label          Port Type      # ports    # populated     cable type      shielded     ferrite   length    max     in/out   under       comment
                                                                                                  s        (m)    length             test
                                                                                                                    (m)
None

Software Operating Mode Description:
Radio Operating Frequencies: 2.4-2.483 GHz (channel 37,38, 39 only: 2402, 2426, 2480 MHz) - non-connectable




                         _____________________________________________________________
                 Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                 One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                               page 5 of 25


                     Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
             ______________________________________________________________________



Statement of Conformity
The WFPS-1 Smart Pressure Switch has been found to conform to the following parts of 47
CFR and RSS 247 as detailed below:



RSS-GEN       RSP-100          RSS 247          Part 15         Comments
6.3                                             15.15(b)        There are no controls accessible to the user that
                                                                varies the output power to operate in violation of the
                                                                regulatory requirements.
              3.1                               15.19           The label is shown in the label exhibit.
              3.2                               15.21           Information to the user is shown in the instruction
                                                                manual exhibit.
                                                15.27           No special accessories are required for compliance.
6.1, 6.5                                        15.31           The EUT was tested in accordance with the
                                                                measurement standards in this section.
                                                15.33           Frequency range was investigated according to this
                                                                section, unless noted in specific rule section under
                                                                which the equipment operates.
8.1                                             15.35           The EUT emissions were measured using the
                                                                measurement detector and bandwidth specified in
                                                                this section, unless noted in specific rule section
                                                                under which the equipment operates.
8.3                                             15.203          The antenna for this device is non removable
                                                                integrated antenna and it is hardwired to the PCB
                                                                with a gain of 2.1dBi
8.10                                            15.205          The fundamental is not in a Restricted band and the
                                                15.209          spurious and harmonic emissions in the Restricted
                                                                bands comply with the general emission limits of
                                                                15.209 or RSS-Gen as applicable
8.8                                             15.207          N/A. EUT is battery powered.
                                                15.247          The unit complies with the requirements of 15.247
                               RSS 247                          The unit complies with the requirements of RSS-247
6.6                                                             Occupied Bandwidth measurements were made.



Modifications Required for Compliance
None.




                    _____________________________________________________________
           Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
           One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 6 of 25


                                 Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
                         ______________________________________________________________________



Test Results

Bandwidth
LIMIT
The minimum 6 dB bandwidth shall be at least 500 kHz. [15.247(a) (2)]

MEASUREMENTS / RESULTS


DTS Bandwidth
      Date: 15-Jan-16                                  Company: Powercast                                                                                        Work Order: P2678
 Engineer: Jason Haley                                 EUT Desc: WFPS-1                                                                     EUT Operating Voltage/Frequency: 3V battery
     Temp: 22.3°C                                       Humidity: 37%                                          Pressure: 1007mBar


Notes: Measurements of the Occupied Bandwidth IAW Ansi C63.10_2013, Section 6.9.2, per FCC CFR 47 part 15.247 (a) (2).
              Frequency                               Measured DTS Bandw idth                                   DTS Bandw idth Lim it                        Test Result
                 (MHz)                                           (kHz)                                                    (kHz)
                 2402                                            500                                              at least 500kHz                               Pass
                 2426                                            675                                              at least 500kHz                               Pass
                 2480                                            650                                              at least 500kHz                               Pass


Rev. 1/14/2016
Spectrum Analyzers / Receivers /Preselectors            Range                MN                Mfr                SN              Asset   Cat     Calibration Due Calibrated on
            SA EMI Chamber (1328)                  9kHz-13.2 GHz          E4405B             Agilent        MY44210241            1328     I         8/19/2016      8/19/2015
_
           Radiated Emissions Sites                   FCC Code           IC Code          VCCI Code             Range                     Cat     Calibration Due Calibrated on
                 EMI Chamber 2                          719150           2762A-7            A-0015           30-1000MHz                    II        3/22/2017      3/22/2015
_
    Preamps /Couplers Attenuators / Filters             Range                MN                Mfr                SN              Asset   Cat     Calibration Due Calibrated on
                1517 HF Preamp                         1-20GHz               CS                CS                N/A              1517     II         8/6/2016      8/6/2015
_
                    Antennas                            Range                MN                Mfr                SN              Asset   Cat     Calibration Due Calibrated on
                   Blue Horn                           1-18Ghz              3117              ETS               157647            1861     I          2/8/2017      2/8/2015
_
            Meteorological Meters                                            MN                Mfr                SN              Asset   Cat     Calibration Due Calibrated on
         Weather Clock (Pressure Only)                                     BA928       Oregon Scientific       C3166-1             831     I         3/19/2016      3/19/2014
                   TH A#2081                                               HTC-1              HDE                                 2081     II         4/2/2016       4/2/2015
_
                      Cables                            Range                                  Mfr                                        Cat     Calibration Due Calibrated on
                  Asset #2052                       9kHz - 18GHz                           Florida RF                                      II         3/8/2016      3/8/2015
                  Asset #2053                       9kHz - 18GHz                           Florida RF                                      II         3/8/2016      3/8/2015
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                                   _____________________________________________________________
                     Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                     One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                 page 7 of 25


                  Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
          ______________________________________________________________________


PLOTS




                           6dB Bandwidth Plot, Low Channel




                _____________________________________________________________
        Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
        One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 8 of 25


          Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
  ______________________________________________________________________




                6dB Bandwidth Plot, Middle Channel




                  6dB Bandwidth Plot, High Channel
        _____________________________________________________________
Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 9 of 25


                              Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
                      ______________________________________________________________________



Fundamental Emission Output Power
LIMIT

Conducted Output Power
1W = 30dBm
[15.247(b) (3)]

MEASUREMENTS / RESULTS
 Radiated Emissions Table                                                                              CSsoft Radiated Emissions Calculator       v 1.017.154
          Date: 15-Jan-16               Company: Powercast                                                                                      Work Order: P2678
    Engineer: Jason Haley               EUT Desc: WFPS-1                                                               EUT Operating Voltage/Frequency: Battery
        Temp: 22°C                      Humidity: 27%                        Pressure: 1007mBar
                      Frequency Range: 1-6GHz                                                                          Measurement Distance: 3 m
         Notes: Maximized                                                                                                        EUT Max Freq: 2480

                                                                                                                                                 FCC 15.247
   Antenna                               Pream p   Antenna    Cable     Adjusted         Adjusted       Antenna         Final
  Polarization   Frequency    Reading     Factor    Factor    Factor     Reading        EIRP Reading      Gain    Conducted Reading    Lim it      Margin             Result
     (H / V)        (MHz)     (dBµV)       (dB)     (dB/m)     (dB)     (dBµV/m)           (dBm)          (dBi)         (dBm)          (dBm)         (dB)           (Pass/Fail)
   V, low ch       2402.0      77.1        19.9      32.3      3.3           92.8           -2.4          2.1            -4.5          30.0         -34.5             Pass
   V, mid ch       2426.0      78.3        20.0      32.3      3.3           93.9           -1.3          2.1            -3.4          30.0         -33.4             Pass
   V, high ch      2480.0      71.7        20.2      32.4      3.3           87.2           -8.0          2.1           -10.1          30.0         -40.1             Pass

        Table Result:         Pass         by         -33.4 dB                                                                   Worst Freq:        2426.0 MHz
    Test Site: EMI Chamber 2             Cable 1: Asset #2052                                            Cable 2: Asset #2053                      Cable 3: ---
    Analyzer: Asset #1328                Preamp: Asset #1517                                            Antenna: Blue Horn                      Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.154                                                                                                Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor
Per: DTS Meas Guidance Section 9.1.1
 Rev. 1/14/2016
Spectrum Analyzers / Receivers /Preselectors           Range          MN              Mfr             SN       Asset            Cat Calibration Due Calibrated on
            SA EMI Chamber (1328)                 9kHz-13.2 GHz E4405B              Agilent     MY44210241 1328                  I     8/19/2016      8/19/2015
 _
           Radiated Emissions Sites                 FCC Code       IC Code       VCCI Code          Range                       Cat Calibration Due Calibrated on
                 EMI Chamber 2                         719150      2762A-7          A-0015      30-1000MHz                       II    3/22/2017      3/22/2015
 _
    Preamps /Couplers Attenuators / Filters            Range          MN              Mfr             SN       Asset            Cat Calibration Due Calibrated on
                1517 HF Preamp                        1-20GHz         CS              CS              N/A       1517             II     8/6/2016      8/6/2015
 _
                    Antennas                           Range          MN              Mfr             SN       Asset            Cat Calibration Due Calibrated on
                    Blue Horn                         1-18Ghz        3117            ETS            157647      1861             I      2/8/2017      2/8/2015
 _
            Meteorological Meters                                     MN              Mfr             SN       Asset            Cat Calibration Due Calibrated on
          Weather Clock (Pressure Only)                             BA928 Oregon Scientific        C3166-1      831              I     3/19/2016      3/19/2014
                   TH A#2081                                         HTC-1           HDE                        2081             II     4/2/2016       4/2/2015
 _
                      Cables                           Range                          Mfr                                       Cat Calibration Due Calibrated on
                   Asset #2052                     9kHz - 18GHz                   Florida RF                                     II     3/8/2016      3/8/2015
                   Asset #2053                     9kHz - 18GHz                   Florida RF                                     II     3/8/2016      3/8/2015
 _
 All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                             _____________________________________________________________
                   Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                   One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                      page 10 of 25


                  Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
          ______________________________________________________________________


PLOTS




                            Peak Output Power, Low Channel




                _____________________________________________________________
        Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
        One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 11 of 25


          Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
  ______________________________________________________________________




                 Peak Output Power, Middle Channel




                   Peak Output Power, High Channel
        _____________________________________________________________
Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 12 of 25


                                     Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
                             ______________________________________________________________________



Band Edge Measurements
LIMITS
Radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), must also
comply with the radiated emission limits specified in Section 15.209(a).
[15.247(d)]

MEASUREMENTS / RESULTS
Radiated Emissions Table - Band Edge                                                                                               CSsoft Radiated Emissions Calculator                   v 1.017.154
           Date: 27-Jan-16                          Company: Powercast Corporation                                                                                            Work Order: P2678
   Engineer: Tuyen Truong                           EUT Desc: WFPS-1                                                                          EUT Operating Voltage/Frequency: 3Vdc
       Temp: 21°C                                   Humidity: 23%                                        Pressure: 1005mBar
                                 Frequency Range: Band Edge                                                                                   Measurement Distance: 3 m
        Notes:                                                                                                                                                  EUT Tx Freq: 2402-2480 MHz


                                                                                                                    FCC 15.209 High Frequency - Peak FCC 15.209 High Frequency - Average
   Antenna                       Peak     Average    Pream p   Antenna    Cable      Adjusted          Adjusted
 Polarization     Frequency     Reading   Reading     Factor    Factor   Factor     Peak Reading      Avg Reading       Lim it       Margin        Result           Lim it       Margin              Result
    (H / V)          (MHz)      (dBµV)    (dBµV)       (dB)     (dB/m)       (dB)     (dBµV/m)         (dBµV/m)        (dBµV/m)       (dB)        (Pass/Fail)      (dBµV/m)        (dB)            (Pass/Fail)
       v            2483.5      34.48      22.6        20.2     32.4         3.9       50.6              38.7           74.0          -23.4         Pass             54.0         -15.3               Pass
       v            2400.0      53.5       21.8        19.9     32.3         3.7       69.6              37.9           74.0           -4.4         Pass             54.0         -16.1               Pass
       v            2390.0      34.36      22.3        19.9     32.3         3.7       50.5              38.4           74.0          -23.5         Pass             54.0         -15.6               Pass

       Table Result:                      Pass          by          -4.4 dB                                                                                 Worst Freq:           2400.0 MHz
    Test Site: EMI Chamber 1                        Cable 1: Asset #2051                                                             Cable 2: Asset #1784                        Cable 3: ---
    Analyzer: Rental SA#1                          Preamp: Asset #1517                                                              Antenna: Blue Horn                        Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.154                                                                                                                                 Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor


Rev. 1/26/2016
      Spectrum Analyzers / Receivers /Preselectors                  Range              MN                Mfr               SN             Asset      Cat         Calibration Due            Calibrated on
                         SA #2 (1860)                          9kHz-26.5 GHz         E7405A             Agilent         MY45104916        1860        I            12/23/2016                12/23/2015
_
                 Radiated Emissions Sites                         FCC Code          IC Code          VCCI Code             Range                     Cat         Calibration Due            Calibrated on
                        EMI Chamber 1                               719150          2762A-6           A-0015              1-18GHz                     I             5/23/2017                 5/23/2015
_
         Preamps /Couplers Attenuators / Filters                    Range              MN                Mfr                 SN           Asset      Cat         Calibration Due            Calibrated on
                       1517 HF Preamp                              1-20GHz             CS                CS                  N/A          1517        II             8/6/2016                 8/6/2015
_
                          Antennas                                  Range              MN                Mfr                 SN           Asset      Cat         Calibration Due            Calibrated on
                          Blue Horn                                1-18Ghz            3117               ETS               157647         1861        I              2/8/2017                 2/8/2015
_
                  Meteorological Meters                                               MN                 Mfr                SN            Asset      Cat         Calibration Due            Calibrated on
               Weather Clock (Pressure Only)                                         BA928         Oregon Scientific      C3166-1          831        I             3/19/2016                 3/19/2014
                          TH A#2080                                                  HTC-1              HDE                               2080        II             4/2/2016                 4/2/2015
_
                            Cables                                  Range                                 Mfr                                        Cat         Calibration Due            Calibrated on
                         Asset #1784                            9kHz - 18GHz                          Florida RF                                      II            3/20/2016                 3/20/2015
                         Asset #2051                            9kHz - 18GHz                          Florida RF                                      II             3/8/2016                 3/8/2015
_
All equipment is calibrated using standards traceable to NIST or other nationally   recognized calibration standard.




                                  _____________________________________________________________
                      Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                      One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                                  page 13 of 25


                              Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
                      ______________________________________________________________________




Radiated Spurious Emissions
LIMITS
Radiated emissions which fall in the restricted bands, as defined in Section 15.205(a), must also
comply with the radiated emission limits specified in Section 15.209(a).
[15.247(d)]

MEASUREMENTS / RESULTS
Radiated Emissions Table                                                                                       CSsoft Radiated Emissions Calculator                         v 1.017.147
           Date: 16-Sep-15                   Company: Powercast                                                                                                 Work Order: P2678
    Engineer: Jason Haley                    EUT Desc: WFPS-1                                                                   EUT Operating Voltage/Frequency: 3V battery
        Temp: 22.5°C                          Humidity: 50%                          Pressure: 1019 mBar
                       Frequency Range: 30-1000 MHz                                                                         Measurement Distance: 3 m
        Notes:                                                                                                                             EUT Max Freq: 2480

                                                                                                                    ---                                          FCC 15.209
   Antenna                                     Pream p     Antenna     Cable       Adjusted
 Polarization     Frequency       Reading       Factor      Factor     Factor      Reading           Lim it       Margin          Result              Lim it       Margin             Result
    (H / V)          (MHz)         (dBµV)        (dB)       (dB/m)      (dB)       (dBµV/m)        (dBµV/m)        (dB)          (Pass/Fail)         (dBµV/m)        (dB)           (Pass/Fail)
       V            146.65          36.5         25.5        12.6       0.6          24.2             ---           ---              ---                 43.5       -19.3             Pass
       V            152.57          35.5         25.4        12.4       0.7          23.2             ---           ---              ---                 43.5       -20.3             Pass
       V             165.0          35.3         25.6        12.0       0.8          22.5             ---           ---              ---                 43.5       -21.0             Pass
       V            178.15          33.8         25.5        11.2       0.7          20.2             ---           ---              ---                 43.5       -23.3             Pass
       V             84.0           32.8         25.4         7.5       0.5          15.4             ---           ---              ---                 40.0       -24.6             Pass
       V             54.75          30.9         25.2         7.2       0.5          13.4             ---           ---              ---                 40.0       -26.6             Pass
       H            158.37          34.8         25.5        12.3       0.8          22.4             ---           ---              ---                 43.5       -21.1             Pass
       H            152.33          34.1         25.4        12.5       0.7          21.9             ---           ---              ---                 43.5       -21.6             Pass
       H            164.41          33.2         25.6        12.0       0.8          20.4             ---           ---              ---                 43.5       -23.1             Pass
       H            149.01          30.0         25.4        12.5       0.7          17.8             ---           ---              ---                 43.5       -25.7             Pass
       H            170.57          28.3         25.6        11.6       0.8          15.1             ---           ---              ---                 43.5       -28.4             Pass

       Table Result:              Pass            by          -19.3 dB                                                                     Worst Freq:              146.65 MHz
    Test Site: EMI Chamber 1             Cable 1: Asset #2051                                                     Cable 2: Asset #2054                             Cable 3: ---
    Analyzer: Rental SA#2                Preamp: Red-White                                                       Antenna: Red-Brown                             Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.147                                                                                                                Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor
Note: This is a worst-case of all three channels (Low, Mid and High)
Rev.9/16/2015                                                                                                                                        _
      Spectrum Analyzers / Receivers /Preselectors                  Range               MN               Mfr           SN         Asset        Cat       Calibration Due       Calibrated on
                             Gold                              100Hz-26.5 GHz         E4407B           Agilent     MY45113816     1284          I           4/22/2016
_
                 Radiated Emissions Sites                         FCC Code           IC Code        VCCI Code        Range                     Cat       Calibration Due       Calibrated on
                        EMI Chamber 1                               719150           2762A-6           A-0015      30-1000MHz                   II          3/21/2017            3/21/2015
_
         Preamps /Couplers Attenuators / Filters                    Range               MN               Mfr           SN         Asset        Cat       Calibration Due       Calibrated on
                          Red-White                            0.009-2000MHz ZFL-1000-LN                 CS            N/A        1258          II         12/26/2015           12/26/2014
_
                          Antennas                                  Range               MN               Mfr           SN         Asset        Cat       Calibration Due       Calibrated on
                       Red-Brown Bilog                           30-2000MHz             JB1             Sunol       A0032406      1218          I           12/4/2016            12/4/2014
_
                            Cables                                  Range                                Mfr                                   Cat       Calibration Due       Calibrated on
                         Asset #2051                            9kHz - 18GHz                         Florida RF                                 II           3/8/2016            3/8/2015
                         Asset #2054                            9kHz - 18GHz                         Florida RF                                 II           3/8/2016            3/8/2015
_
                  Meteorological Meters                                                 MN               Mfr           SN         Asset        Cat       Calibration Due       Calibrated on
               Weather Clock (Pressure Only)                                          BA928      Oregon Scientific   C3166-1       831          I           3/19/2016            3/19/2014
                          TH A#2081                                                    HTC-1            HDE                       2081          II           4/2/2016
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                               _____________________________________________________________
                   Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                   One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                       page 14 of 25


                               Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
                       ______________________________________________________________________

Radiated Emissions Table                                                                                                     CSsoft Radiated Emissions Calculator                  v 1.017.147
         Date: 16-Sep-15                           Company: Powercast                                                                                                  Work Order: P2678
   Engineer: Jason Haley                           EUT Desc: WFPS-1                                                                       EUT Operating Voltage/Frequency: 3V battery
       Temp: 22.5°C                                Humidity: 50%                                      Pressure: 1019 mBar
                               Frequency Range: 1-6GHz                                                                                    Measurement Distance: 3 m
        Notes:                                                                                                                                      EUT Max Freq: 2480

                                                                                                                 FCC 15.209 High Frequency - Peak            FCC 15.209 High Frequency -
   Antenna                    Peak      Average     Pream p   Antenna    Cable       Adjusted       Adjusted                                                          Average
 Polarization    Frequency   Reading     Reading     Factor    Factor    Factor     Peak Reading   Avg Reading     Lim it      Margin        Result          Lim it       Margin             Result
    (H / V)        (MHz)      (dBµV)     (dBµV)       (dB)     (dB/m)        (dB)     (dBµV/m)      (dBµV/m)      (dBµV/m)      (dB)       (Pass/Fail)      (dBµV/m)        (dB)           (Pass/Fail)
    V N.F.        1883.0      28.49       28.5        18.9      27.5         2.9       40.0           40.0          74.0        -34.0        Pass            54.0          -14.0             Pass
    H N.F.        4207.0      31.71       28.6        18.7      32.1         4.3       49.4           46.3          74.0        -24.6        Pass            54.0           -7.7             Pass

       Table Result:                     Pass         by           -7.7 dB                                                                            Worst Freq:          4207.0 MHz
    Test Site: EMI Chamber 1                        Cable 1: Asset #2051                                                       Cable 2: Asset #2054                       Cable 3: ---
    Analyzer: Rental SA#2                          Preamp: Asset #1517                                                        Antenna: Black Horn                      Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.147                                                                                                                       Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor

Note: This is a worst-case of all three channels (Low, Mid and High)

Rev.9/17/2015                                                                                                                                       _
      Spectrum Analyzers / Receivers /Preselectors                 Range             MN             Mfr              SN           Asset     Cat          Calibration Due           Calibrated on
                         SA #2 (1860)                         9kHz-26.5 GHz E7405A                Agilent       MY45104916        1860       I              7/30/2016
_
                 Radiated Emissions Sites                        FCC Code        IC Code       VCCI Code           Range                    Cat          Calibration Due           Calibrated on
                       EMI Chamber 2                               719150         2762A-7         A-0015        30-1000MHz                   II             3/22/2017                3/22/2015
_
         Preamps /Couplers Attenuators / Filters                   Range             MN             Mfr              SN           Asset     Cat          Calibration Due           Calibrated on
                            Brown                                 1-10GHz            CS             CS               N/A          1523       II              4/9/2016                4/9/2015
_
                          Antennas                                 Range             MN             Mfr              SN           Asset     Cat          Calibration Due           Calibrated on
                          Black Horn                              1-18GHz           3115          EMCO            9703-5148        56        I              8/21/2016                8/21/2014
_
                            Cables                                 Range                            Mfr                                     Cat          Calibration Due           Calibrated on
                         Asset #2051                           9kHz - 18GHz                     Florida RF                                   II              3/8/2016                3/8/2015
                         Asset #2054                           9kHz - 18GHz                     Florida RF                                   II              3/8/2016                3/8/2015
_
                  Meteorological Meters                                              MN             Mfr              SN           Asset     Cat          Calibration Due           Calibrated on
               Weather Clock (Pressure Only)                                       BA928    Oregon Scientific      C3166-1         831       I              3/19/2016                3/19/2014
                          TH A#2080                                                HTC-1           HDE                            2080       II              4/2/2016                 4/2/2015
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.



Radiated Emissions Table                                                                                                     CSsoft Radiated Emissions Calculator                  v 1.017.147
         Date: 16-Sep-15                           Company: Powercast                                                                                                  Work Order: P2678
   Engineer: Jason Haley                           EUT Desc: WFPS-1                                                                       EUT Operating Voltage/Frequency: 3V battery
       Temp: 22.5°C                                Humidity: 50%                                      Pressure: 1019 mBar
                               Frequency Range: 1-6GHz                                                                                    Measurement Distance: 1 m
        Notes:                                                                                                                                      EUT Max Freq: 2480

                                                                                                                 FCC 15.209 High Frequency - Peak            FCC 15.209 High Frequency -
   Antenna                    Peak      Average     Pream p   Antenna    Cable       Adjusted       Adjusted                                                          Average
 Polarization    Frequency   Reading     Reading     Factor    Factor    Factor     Peak Reading   Avg Reading     Lim it      Margin        Result          Lim it       Margin             Result
    (H / V)        (MHz)      (dBµV)     (dBµV)       (dB)     (dB/m)        (dB)     (dBµV/m)      (dBµV/m)      (dBµV/m)      (dB)       (Pass/Fail)      (dBµV/m)        (dB)           (Pass/Fail)
    V N.F.       7440.0       32.1        17.6        17.2      37.9         5.7       58.5           44.0          83.5        -25.0        Pass            63.5          -19.5             Pass
    H N.F.       14880.0      32.24       19.2        17.0      40.8         8.0       64.0           51.0          83.5        -19.5        Pass            63.5          -12.5             Pass
    V N.F.       17360.0      29.95       18.4        15.8      43.5         8.7       66.4           54.8          83.5        -17.1        Pass            63.5           -8.7             Pass

       Table Result:                     Pass         by           -8.7 dB                                                                            Worst Freq:        17360.0 MHz
    Test Site: EMI Chamber 1                        Cable 1: Asset #2051                                                       Cable 2: Asset #2054                       Cable 3: ---
    Analyzer: Rental SA#2                          Preamp: Asset #1517                                                        Antenna: Black Horn                      Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.147                                                                                                                       Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor

Note: This is a worst-case of all three channels (Low, Mid and High)




                               _____________________________________________________________
                    Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                    One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                           page 15 of 25


                                  Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
                          ______________________________________________________________________

Rev.9/17/2015                                                                                                                                                 _
      Spectrum Analyzers / Receivers /Preselectors                 Range             MN             Mfr              SN                   Asset     Cat           Calibration Due            Calibrated on
                         SA #2 (1860)                         9kHz-26.5 GHz E7405A                Agilent       MY45104916                1860       I               7/30/2016
_
                 Radiated Emissions Sites                        FCC Code        IC Code       VCCI Code           Range                            Cat           Calibration Due            Calibrated on
                       EMI Chamber 2                               719150         2762A-7         A-0015        30-1000MHz                           II              3/22/2017                 3/22/2015
_
         Preamps /Couplers Attenuators / Filters                   Range             MN             Mfr              SN                   Asset     Cat           Calibration Due            Calibrated on
                            Brown                                 1-10GHz            CS             CS               N/A                  1523       II               4/9/2016                 4/9/2015
_
                          Antennas                                 Range             MN             Mfr              SN                   Asset     Cat           Calibration Due            Calibrated on
                          Black Horn                              1-18GHz           3115          EMCO            9703-5148                56        I               8/21/2016                 8/21/2014
_
                            Cables                                 Range                            Mfr                                             Cat           Calibration Due            Calibrated on
                         Asset #2051                           9kHz - 18GHz                     Florida RF                                           II               3/8/2016                 3/8/2015
                         Asset #2054                           9kHz - 18GHz                     Florida RF                                           II               3/8/2016                 3/8/2015
_
                  Meteorological Meters                                              MN             Mfr              SN                   Asset     Cat           Calibration Due            Calibrated on
               Weather Clock (Pressure Only)                                       BA928    Oregon Scientific      C3166-1                 831       I               3/19/2016                 3/19/2014
                          TH A#2080                                                HTC-1           HDE                                    2080       II               4/2/2016                  4/2/2015
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.



Radiated Emissions Table                                                                                                             CSsoft Radiated Emissions Calculator                    v 1.017.147
         Date: 17-Sep-15                                 Company: Powercast                                                                                                      Work Order: P2678
    Engineer: Jason Haley                                EUT Desc: WFPS-1                                                                         EUT Operating Voltage/Frequency: 3V battery
        Temp: 22.3°C                                     Humidity: 52%                                        Pressure: 1013mBar
                                       Frequency Range: 18-26.5GHz                                                                                Measurement Distance: 0.1 m
        Notes:                                                                                                                                                EUT Max Freq: 2480 MHz

                                                                                                                         FCC 15.209 High Frequency - Peak               FCC 15.209 High Frequency -
   Antenna                            Peak     Average    Pream p    Antenna     Cable       Adjusted       Adjusted                                                             Average
 Polarization     Frequency       Reading      Reading     Factor    Factor      Factor     Peak Reading   Avg Reading     Lim it      Margin        Result             Lim it      Margin             Result
    (H / V)          (MHz)            (dBµV)    (dBµV)      (dB)      (dB/m)      (dB)        (dBµV/m)      (dBµV/m)      (dBµV/m)      (dB)       (Pass/Fail)        (dBµV/m)        (dB)           (Pass/Fail)
No signals within 10dB of the limit                         ---        ---            ---        ---           ---           ---         ---            ---              ---           ---               ---

       Table Result:                             ---        by               --- dB                                                                           Worst Freq:                    --- MHz
    Test Site: EMI Chamber 1                        Cable 1: EMIR-HIGH-07                                                              Cable 2: ---                                 Cable 3: ---
    Analyzer: Gold                                 Preamp: 18-26.5GHz                                                                 Antenna: 18-26.5GHz Horn                   Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.147                                                                                                                                 Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor

Note: This is a worst-case of all three channels (Low, Mid and High)

Rev.9/16/2015                                                                                                                                                     _
      Spectrum Analyzers / Receivers /Preselectors                   Range                    MN                     Mfr            SN          Asset     Cat         Calibration Due         Calibrated on
                             Gold                              100Hz-26.5 GHz               E4407B                 Agilent      MY45113816      1284       I             4/22/2016              4/22/2015
_
                 Radiated Emissions Sites                         FCC Code                 IC Code               VCCI Code         Range                  Cat         Calibration Due         Calibrated on
                        EMI Chamber 1                                719150                2762A-6                 A-0015       30-1000MHz                 II            3/21/2017              3/21/2015
_
         Preamps /Couplers Attenuators / Filters                     Range                    MN                     Mfr            SN          Asset     Cat         Calibration Due         Calibrated on
                          HF (Yellow)                             18-26.5GHz       AFS4-18002650-60-8P-4             CS           467559        1266       II            3/13/2016              3/13/2015
_
                          Antennas                                   Range                    MN                     Mfr            SN          Asset     Cat         Calibration Due         Calibrated on
                       HF (White) Horn                            18-26.5GHz              801-WLM                  Waveline         758          758       III        Verify before Use        date of test
_
                            Cables                                   Range                                           Mfr                                  Cat         Calibration Due         Calibrated on
                         REMI-High-07                             1 - 26.5GHz         TRU-21B0707-120               TRU                                    II             8/7/2016              8/7/2015
_                                                                                                                                                                                               3/8/2015
                  Meteorological Meters                                                       MN                     Mfr            SN          Asset     Cat         Calibration Due         Calibrated on
               Weather Clock (Pressure Only)                                                BA928             Oregon Scientific   C3166-1        831       I             3/19/2016              3/19/2014
                          TH A#2081                                                          HTC-1                  HDE                         2081       II             4/2/2016              3/19/2014
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                                       _____________________________________________________________
                      Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                      One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                                   page 16 of 25


                              Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
                      ______________________________________________________________________




Power Spectral Density
LIMIT
…the power spectral density conducted from the intentional radiator to the antenna shall not be
greater than 8dBm in any 3kHz band during any time interval of continuous transmission.
[15.247(e)]

MEASUREMENTS / RESULTS
Power Spectral Density                                                                                     CSsoft Radiated Emissions Calculator              v 1.017.148
           Date: 18-Sep-15                Company: Powercast                                                                                               Work Order: P2678
   Engineer: CL/TT                        EUT Desc: WFPS-1                                                                     EUT Operating Voltage/Frequency: 3Vdc
       Temp: 22.4°C                        Humidity: 52%                       Pressure: 1010mBar
                      Frequency Range: Fundamental Frequencies                                                                Measurement Distance: 3 m
        Notes:                                                                                                                          TX Frequency: 2402-2480MHz

                                                                                                                                                            FCC 15.247
   Antenna                                  Pream p    Antenna     Cable     Adjusted        Adjusted       Antenna            Final
 Polarization     Frequency     Reading      Factor     Factor    Factor      Reading       EIRP Reading      Gain      Conducted Reading         Lim it      Margin             Result
    (H / V)         (MHz)        (dBµV)       (dB)      (dB/m)     (dB)       (dBµV/m)         (dBm)          (dBi)            (dBm)              (dBm)         (dB)           (Pass/Fail)
       v           2402.0         66.4        18.8       28.6       3.3         79.5           -15.7           2.1             -17.8               8.0         -25.8             Pass
       v           2426.0         64.3        18.8       28.7       3.3         77.5           -17.7           2.1             -19.8               8.0         -27.8             Pass
       v           2480.0         60.8        18.9       28.8       3.4         74.1           -21.1           2.1             -23.2               8.0         -31.2             Pass

       Table Result:            Pass           by         -25.8 dB                                                                      Worst Freq:            2402.0 MHz
    Test Site: EMI Chamber 1             Cable 1: Asset #2051                                                Cable 2: Asset #2054                             Cable 3: ---
    Analyzer: Rental SA#1                Preamp: Brown                                                      Antenna: Black Horn                            Preselector: ---
CSsoft Radiated Emissions Calculator   v 1.017.148                                                                                                           Co pyright Curtis-Straus LLC 2000
Adjusted Reading = Reading - Preamp Factor + Antenna Factor + Cable Factor
Per: DTS Meas Guidance Section 10.2
Rev.9/17/2015                                                                                                                                _
      Spectrum Analyzers / Receivers /Preselectors                 Range             MN             Mfr              SN       Asset    Cat       Calibration Due        Calibrated on
                         SA #2 (1860)                         9kHz-26.5 GHz E7405A                Agilent       MY45104916    1860      I           7/30/2016
_
                 Radiated Emissions Sites                        FCC Code        IC Code       VCCI Code           Range               Cat       Calibration Due        Calibrated on
                       EMI Chamber 2                               719150         2762A-7         A-0015        30-1000MHz              II          3/22/2017             3/22/2015
_
         Preamps /Couplers Attenuators / Filters                   Range             MN             Mfr              SN       Asset    Cat       Calibration Due        Calibrated on
                            Brown                                 1-10GHz            CS             CS               N/A      1523      II           4/9/2016             4/9/2015
_
                          Antennas                                 Range             MN             Mfr              SN       Asset    Cat       Calibration Due        Calibrated on
                          Black Horn                              1-18GHz           3115          EMCO            9703-5148    56       I           8/21/2016             8/21/2014
_
                            Cables                                 Range                            Mfr                                Cat       Calibration Due        Calibrated on
                         Asset #2051                           9kHz - 18GHz                     Florida RF                              II           3/8/2016             3/8/2015
                         Asset #2054                           9kHz - 18GHz                     Florida RF                              II           3/8/2016             3/8/2015
_
                  Meteorological Meters                                              MN             Mfr              SN       Asset    Cat       Calibration Due        Calibrated on
               Weather Clock (Pressure Only)                                       BA928    Oregon Scientific      C3166-1     831      I           3/19/2016             3/19/2014
                          TH A#2080                                                HTC-1           HDE                        2080      II           4/2/2016              4/2/2015
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                              _____________________________________________________________
                    Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                    One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                                page 17 of 25


                  Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
          ______________________________________________________________________


PLOTS




                       Power Spectral Density, Low Channel




                    Power Spectral Density, Middle Channel


                _____________________________________________________________
        Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
        One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 18 of 25


          Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
  ______________________________________________________________________




              Power Spectral Density, High Channel




        _____________________________________________________________
Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 19 of 25


                               Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
                       ______________________________________________________________________



Occupied Bandwidth
REQUIREMENT
When an occupied bandwidth is not specified in the applicable RSS, the transmitted signal
bandwidth to be reported is to be its 99% emission bandwidth, as calculated or measured.
[RSS-GEN 6.6]

                                                                    Occupied Bandwidth
     Date: 18-Sep-15                             Company: Powercast                                                                                            Work Order: P2678
 Engineer: Jason Haley                           EUT Desc: WFPS-1                                                                     EUT Operating Voltage/Frequency: 3V battery
    Temp: 22.3°C                                 Humidity: 52%                                   Pressure: 1013mBar


Notes: Measurements of the Occupied Bandwidth - Power Bandwidth (99%) per Ansi C63.10_2013, Section 6.9.3
                                    Frequency                                                                         Occupied Bandw idth Pow er 99%
                                       (MHz)                                                                                      (MHz)
                                       2402                                                                                      1.0123
                                       2426                                                                                      1.0214
                                       2480                                                                                      1.0324
Rev.9/17/2015                                                                                                                                   _
      Spectrum Analyzers / Receivers /Preselectors                 Range             MN             Mfr              SN       Asset       Cat       Calibration Due   Calibrated on
                         SA #2 (1860)                         9kHz-26.5 GHz E7405A                Agilent       MY45104916    1860         I           7/30/2016
_
                 Radiated Emissions Sites                        FCC Code        IC Code       VCCI Code           Range                  Cat       Calibration Due   Calibrated on
                       EMI Chamber 2                               719150         2762A-7         A-0015        30-1000MHz                 II          3/22/2017        3/22/2015
_
         Preamps /Couplers Attenuators / Filters                   Range             MN             Mfr              SN       Asset       Cat       Calibration Due   Calibrated on
                            Brown                                 1-10GHz            CS             CS               N/A      1523         II           4/9/2016        4/9/2015
_
                          Antennas                                 Range             MN             Mfr              SN       Asset       Cat       Calibration Due   Calibrated on
                          Black Horn                              1-18GHz           3115          EMCO            9703-5148    56          I           8/21/2016        8/21/2014
_
                            Cables                                 Range                            Mfr                                   Cat       Calibration Due   Calibrated on
                         Asset #2051                           9kHz - 18GHz                     Florida RF                                 II           3/8/2016        3/8/2015
                         Asset #2054                           9kHz - 18GHz                     Florida RF                                 II           3/8/2016        3/8/2015
_
                  Meteorological Meters                                              MN             Mfr              SN       Asset       Cat       Calibration Due   Calibrated on
               Weather Clock (Pressure Only)                                       BA928    Oregon Scientific      C3166-1     831         I           3/19/2016        3/19/2014
                          TH A#2080                                                HTC-1           HDE                        2080         II           4/2/2016         4/2/2015
_
All equipment is calibrated using standards traceable to NIST or other nationally recognized calibration standard.




                              _____________________________________________________________
                   Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                   One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                                                            page 20 of 25


                  Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
          ______________________________________________________________________


PLOTS




                           Occupied Bandwidth, Low Channel




                        Occupied Bandwidth, Middle Channel



                _____________________________________________________________
        Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
        One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 21 of 25


          Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
  ______________________________________________________________________




                  Occupied Bandwidth, High Channel




        _____________________________________________________________
Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828   page 22 of 25


                          Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
                  ______________________________________________________________________



Measurement Uncertainty

The listed uncertainties are the worst case uncertainty for the entire range of measurement. Please note
that the uncertainty values are provided for informational purposes only and are not used in determining
the PASS/FAIL results.

                                 Measurement                                Expanded Uncertainty k=2   Maximum allowable uncertainty
                       Radiated Emissions (30-1000MHz)
                                    NIST                                             5.6dB                          N/A
                                   CISPR                                             4.6dB                     5.2dB (Ucispr)
                        Radiated Emissions (1-26.5GHz)                               4.6dB                          N/A

                      Radiated Emissions (above 26.5GHz)                             4.9dB                          N/A

                              RF power, conducted                                    0.40dB                       0.75dB
    Maximum frequency deviation:
              Within 300Hz and 6kHz of audio frequency / Within 6kHz and            3.4%                           5%
               25kHz of audio frequency                                              0.3dB                          3dB
                            Adjacent channel power                                   1.9dB                          3dB

        Conducted spurious emission of transmitter, valid up to 12.75GHz             2.39dB                         3dB

                        Conducted emission of receivers                              1.3dB                          3dB

              Radiated emission of transmitter, valid up to 26.5GHz                  3.9dB                          6dB

               Radiated emission of transmitter, valid up to 80GHz                   3.3dB                          6dB

               Radiated emission of receiver, valid up to 26.5GHz                    3.9dB                          6dB

                Radiated emission of receiver, valid up to 80GHz                     3.3dB                          6dB

                                    Humidity                                         2.37%                          5%

                                  Temperature                                        0.7°C                         1.0°C

                                      Time                                           4.1%                          10%

                         RF Power Density, Conducted                                 0.4dB                          3dB

                         DC and low frequency voltages                               1.3%                           3%

                             Voltage (AC, <10kHz)                                    1.3%                           2%

                                  Voltage (DC)                                       0.62%                          1%

    The above reflects a 95% confidence level




                           _____________________________________________________________
                Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                           page 23 of 25


                          Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
                  ______________________________________________________________________




Conditions Of Testing
     [Bureau Veritas Consumer Products Services, Inc., a Massachusetts corporation], and/or its affiliates (collectively, the
"Company") will conduct, at the request of the Submitter (“Client”), the tests specified on the submitted Test Request Form or equivalent in
accordance with, and subject to, the following terms and conditions (collectively, “Conditions”):
1. All orders for tests are subject to acceptance by the Company, and no order will constitute a binding commitment of the Company unless
and until such order is accepted by it, as evidenced by the issuance of a written report (“Test Report”) by the Company. The Test Report is
issued solely by the Company, is intended for the exclusive use of Client and shall not be published, used for advertising purposes, copied or
replicated for distribution to any other person or entity or otherwise publicly disclosed without the prior written consent of the Company. By
submitting a request for services to the Company, Client consents to the disclosure to accreditation bodies of those records of Client relevant
to the accreditation body's assessment of the Company's competence and compliance with relevant accreditation criteria. The Company
shall not be liable for any loss or damage whatsoever resulting from the failure of the Company to provide its services within any time period
for completion estimated by the Company. If Client anticipates using the Test Report in any legal proceeding, arbitration, dispute resolution
forum or other proceeding, it shall so notify the Company prior to submitting the Test Report in such proceeding. The Company has no
obligation to provide a fact or expert witness at such proceeding unless the Company agrees in advance to do so for a separate and
additional fee.
2. The Test Report will set forth the findings of the Company solely with respect to the test samples identified therein. Unless specifically
and expressly indicated in the Test Report, the results set forth in such Test Report are not intended to be indicative or representative of the
quality or characteristics of the lot from which a test sample is taken, and Client shall not rely upon the Test Report as being so indicative or
representative of the lot or of the tested product in general. The Test Report will reflect the findings of the Company at the time of testing
only, and the Company shall have no obligation to update the Test Report after its issuance. The Test Report will set forth the results of the
tests performed by the Company based upon the written information provided to the Company. The Test Report will be based solely on the
samples and written information submitted to the Company by Client, and the Company shall not be obligated to conduct any independent
investigation or inquiry with respect thereto.
3. The Company may, in its sole discretion, destroy samples which have been furnished to the Company for testing and which have not
been destroyed in the course of testing. The Company may delegate the performance of all or a portion of the services contemplated
hereunder to an affiliate, agent or subcontractor of the Company, and Client consents to such delegation.
4. These Conditions and the Test Report represent the entire understanding of the parties hereto with respect to the subject matter hereof
and of the Test Report, and no modification, variance or extrapolation with respect thereto shall be permitted without the prior written consent
of the Company.
5. The names, service marks, trademarks and copyrights of the Company and its affiliates, including the names “BUREAU VERITAS,”
“BUREAU VERITAS CONSUMER PRODUCTS SERVICES,” “BVCPS”, “MTL”, “ACTS”, “MTL-ACTS” and CURTIS-STRAUS
(collectively, the “Marks”) are and shall remain the sole property of the Company or its affiliates and shall not be used by Client except solely
to the extent that Client obtains the prior written approval of the Company and then only in the manner prescribed by the Company. Client
shall not contest the validity of the Marks or take any action that might impair the value or goodwill associated with the Marks or the image or
reputation of the Company or its affiliates.
6. Payment in full shall be due 30 days after the date of invoice. Interest shall be due on overdue amounts from the due date until paid at an
interest rate of 1.5% per month or, if less, the maximum rate permitted by law. The Company reserves the right, at any time and from time to
time, to revoke any credit extended to Client. Client shall reimburse the Company for any costs it incurs in collecting past due amounts,
including court costs and fees and expenses of attorneys and collection agencies. The Test Report may not be used or relied upon by Client
if and for so long as Client fails to pay when due any invoice issued by the Company or any affiliate of it to Client or any affiliate or subsidiary
of Client together with interest and penalties, if any, accrued thereon.
7. The Company disclaims any and all responsibility or liability arising out of or in connection with e-mail transmissions of such information.
8. Client understands and agrees that the Company is neither an insurer nor a guarantor, that the Company does not take the place of Client
or any designer, manufacturer, agent, buyer, distributor or transportation or shipping company, and that the Company disclaims all liability in
such capacities. Client further understands that if it seeks assurance against loss or damage, it should obtain appropriate insurance.
9. Client agrees that the Company, by providing the services, does not take the place of Client nor any third party, nor does the Company
release them from any of their obligations, nor does the Company otherwise assume, abridge, abrogate or undertake to discharge any duty
of any third party to Client or any duty of Client or any third party to any other third party, and Client will not release any third party from its
obligations and duties with respect to the tested goods.
10. Client shall, on a timely basis, (a) provide adequate instructions to the Company in order to enable the Company to perform properly its
services, (b) provide, or cause Client's suppliers and contractors to provide, the Company with all documents necessary to enable the
Company to perform its services, (c) furnish the Company with all relevant information regarding Client's intended use and purposes of the
tested goods, (d) advise the Company of essential dates and deadlines relevant to the tested goods and (e) fully exercise all rights and
remedies available to Client against third parties in respect of the tested goods.
11. The Company shall undertake due care and ordinary skill in the performance of its services to Client, and the Company shall accept
responsibility only were such skill has not been exercised and, even in such event, only to the extent of the limitation of liability set forth
herein.
12. If Client desires to assert a claim arising from or relating to (i) the performance, purported performance or non-performance of any
services by the Company or (ii) the sale, resale, manufacture, distribution or use of any tested goods, it must submit that claim to the
Company in a writing that sets forth with particularity the basis for such claim within 60 days from discovery of the potential claim and not
more than six months after the date of issuance of the Test Report to Client. Client waives any and all such claims including, without
limitation, claims that the Test Report is inaccurate, incomplete or misleading or that additional or different testing is required, unless and
then only to the extent that Client submits a written claim to the Company within both such time periods.
13. CLIENT SHALL, EXCEPT TO THE EXTENT OF COMPANY’S LIABILITY TO CLIENT HEREUNDER (WHICH IN NO EVENT SHALL
EXCEED THE LIMITATION OF LIABILITY HEREIN), HOLD HARMLESS AND INDEMNIFY THE COMPANY, ITS AFFILIATES AND THEIR
RESPECTIVE DIRECTORS, OFFICERS, EMPLOYEES, AGENTS AND SUBCONTRACTORS AGAINST ALL ACTUAL OR ALLEGED
THIRD PARTY CLAIMS FOR LOSS, DAMAGE OR EXPENSE OF WHATSOEVER NATURE AND HOWSOEVER ARISING FROM OR
RELATING TO (i) THE PERFORMANCE, PURPORTED PERFORMANCE OR NON-PERFORMANCE OF ANY SERVICES BY THE
COMPANY OR (ii) THE SALE, RESALE, MANUFACTURE, DISTRIBUTION OR USE OF ANY TESTED GOODS.
                         _____________________________________________________________
                Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
                One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                               page 24 of 25


                          Test Report for Powercast Corporation  Report No. EP2678-1 February 12, 2016
                  ______________________________________________________________________

14. EXCEPT AS MAY OTHERWISE BE EXPRESSLY AGREED TO IN WRITING BY THE COMPANY AND NOTWITHSTANDING ANY
PROVISION TO THE CONTRARY CONTAINED HEREIN OR IN ANY TEST REPORT, NO WARRANTY OR GUARANTEE, EXPRESS OR
IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR USE, IS MADE.
15. (A) IN NO EVENT WHATSOEVER SHALL THE COMPANY BE LIABLE FOR ANY CONSEQUENTIAL, SPECIAL, INCIDENTAL,
EXEMPLARY OR PUNITIVE DAMAGES IN CONNECTION WITH, RELATING TO OR ARISING OUT OF THE TEST REPORT OR THE
SERVICES PROVIDED BY THE COMPANY HEREUNDER, INCLUDING WITHOUT LIMITATION LOSS OF OR DAMAGE TO PROPERTY;
LOSS OF INCOME, PROFIT OR USE; OR ANY CLAIMS OR DEMANDS MADE AGAINST CLIENT OR ANY OTHER PERSON BY ANY
THIRD PARTY IN CONNECTION WITH, RELATING TO OR ARISING OUT OF THE SERVICES PROVIDED BY THE COMPANY
HEREUNDER.
  (B)NOTWITHSTANDING ANY PROVISION TO THE CONTRARY CONTAINED HEREIN, AND IN RECOGNITION OF THE RELATIVE
RISKS AND BENEFITS TO CLIENT AND THE COMPANY ASSOCIATED WITH THE TESTING SERVICES CONTEMPLATED HEREBY,
THE RISKS HAVE BEEN ALLOCATED SUCH THAT UNDER NO CIRCUMSTANCES WHATSOEVER SHALL THE LIABILITY OF THE
COMPANY TO CLIENT OR ANY THIRD PARTY IN RESPECT OF ANY CLAIM FOR LOSS, DAMAGE OR EXPENSE, OF WHATSOEVER
NATURE OR MAGNITUDE, AND HOWSOEVER ARISING, EXCEED AN AMOUNT EQUAL TO FIVE (5) TIMES THE AMOUNT OF THE
FEES PAID TO THE COMPANY FOR THE SPECIFIC SERVICES WHICH GAVE RISE TO SUCH CLAIM OR U.S.$10,000, WHICHEVER IS
THE LESSER AMOUNT.
16. The Company shall not be liable for any loss or damage resulting from any delay or failure in performance of its obligations hereunder
resulting directly or indirectly from any event of force majeure or any event outside the control of the Company. If any such event occurs, the
Company may immediately cancel or suspend its performance hereunder without incurring any liability whatsoever to Client.
 17. Company’s services, including these Conditions, shall be governed by, and construed in accordance with, the local laws of the country
where the Company performs the tests or, in the case of tests performed in the United States of America, the laws of Massachusetts without
regard to conflicts of laws principles. If any aspect(s) of these Conditions is found to be illegal or unenforceable, the validity, legality and
enforceability of all remaining aspects of these Conditions shall not in any way be affected or impaired thereby. Any proceeding related to
the subject matter hereof shall be brought, if at all, in the courts of the country where the Company performs the tests or, in the case of tests
performed in the United States of America, in the courts of Massachusetts. Client waives the right to interpose any counterclaim or setoffs of
any nature in any litigation arising hereunder.
The complete list of the Approved Subcontractors Curtis-Straus may use to delegate the performance of work can be provided upon request.
Rev.160009121(2)_#684340 v14CS




                         _____________________________________________________________
               Curtis-Straus LLC, a wholly owned subsidiary of BV CPS
               One Distribution Center Circle, #1  Littleton, MA  TEL (978) 486-8880  FAX (978) 486-8828                             page 25 of 25



Document Created: 2016-02-12 14:55:29
Document Modified: 2016-02-12 14:55:29

© 2024 FCC.report