14a_Audi FPK Gen1 TestRep 15C

FCC ID: YBN-AU-FPK10

Test Report

Download: PDF
FCCID_2535706

                                                         FCC TEST REPORT
                                                           FCC 47 CFR Part 15C
                                                         Industry Canada RSS-210
                                                License exempt radio equipment

Report Reference No. ..................... :              G0M-1409-4198-TFC209LP-V02

Testing Laboratory ......................... :            Eurofins Product Service GmbH

Address............................................. :    Storkower Str. 38c
                                                          15526 Reichenwalde
                                                          Germany

Accreditation ..................................... :




                                                          A2LA Accredited Testing Laboratory, Certificate No.: 1983.01
                                                          FCC Filed Test Laboratory, Reg.-No.: 96970
                                                          IC OATS Filing assigned code: 3470A

Applicant’s name ............................ :           Robert Bosch Car Multimedia GmbH

Address............................................. :    Robert-Bosch-Straße 200
                                                          31139 Hildesheim
                                                          GERMANY

Test specification:

Standard ........................................... :    47 CFR Part 15C
                                                          RSS-210, Issue 8, 2010-12
                                                          RSS-Gen, Issue 3, 2010-12
                                                          ANSI C63.4:2009

Equipment under test (EUT):

Product description                                       Instrument cluster

Model No.                                                 Audi FPK Gen1

Additional Model(s)                                       None

Brand Name(s)                                             BOSCH

Hardware version                                          H33

Firmware / Software version                               0215

                                                          FCC-ID: YBN-AU-FPK10            IC: 9595A-AUFPK10

Test result                                               Passed


                                      Test Report No.: G0M-1409-4198-TFC209LP-V02
                                                    Eurofins Product Service GmbH
                                          Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                           Page 1 of 29


«<= eurofins
                                  | Product Service



Possible test case verdicts:

— neither assesSed NOF teSted ...........c.cscceeeeee l           N/N

— required by standard but not appl. to test object........ :     N/A

— required by standard but not tested.....................?       NT

— not required by standard for the test object...............:    N/R

— test object does meet the requirement.......................:   P (Pass)

— test object does not meet the requirement...                    F (Fail)

Testing:

TESt Lb TEMpPEFAtUF@ .................ccsceeememeeemen=?          20— 23 °C

TESt LQD HUMiQltY ..........sesmmmmmmmmmmmmmmmmmememeenen?.       32— 38 %

Date Of rEC@IPt Of t@St It@M ................cseeeemmee.:         2014—09—29

Date (s) of performance Of tests ........................_..       2014—09—29

Compilad BY :m:—mmmmmemmmemen :                 Christian Weber

Tested by (+ signature).................... 4
(Responsible for Test)                          Sitistan Weber

Approved by (+ signature) ............... :     Toralf Jahn

DAt@ Of ISSU® ... .ccscc :                      2015—02—11

Total number of pages ..................... :   29

General remarks:

The test results presented in this report relate only to the objecttested.
The results contained in this report reflect the results for this particular model and serial
number. It is the responsibility of the manufacturer to ensure that all production models meet
the intent of the requirements detailed within this report.


This report shall not be reproduced, except in full, without the written approval of the Issuing testing
laboratory.

Additional comments:




                               Test Report No.: GOM—1409—4198—TFC209LP—VO2
                                               Eurofins Product Service GmbH
                                    Storkower Str. 38¢, D—15526 Reichenwalde, Germany
                                                                                                Page 2 of 29


Version History
 Version   Issue Date    Remarks                                            Revised by
 01        2015-01-05    Initial Release

 02        2015-02-11    Industry Canada references corrected               C. Weber




                    Test Report No.: G0M-1409-4198-TFC209LP-V02
                                  Eurofins Product Service GmbH
                        Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                               Page 3 of 29


REPORT INDEX


1     EQUIPMENT (TEST ITEM) DESCRIPTION                                                     5

1.1   Photos – Equipment External                                                           6
1.2   Photos – Equipment internal                                                          10
1.3   Photos – Test setup                                                                  14
1.4   Supporting Equipment Used During Testing                                             15
1.5   Test Modes                                                                           16
1.6   Test Equipment Used During Testing                                                   17
1.7   Sample emission level calculation                                                    18

2     RESULT SUMMARY                                                                       19

3     TEST CONDITIONS AND RESULTS                                                          20

3.1   Test Conditions and Results – Occupied Bandwidth                                     20
3.2   Test Conditions and Results – Fundamental field strength emissions                   22
3.4   Test Conditions and Results – Receiver radiated emissions                            24

ANNEX A          Transmitter radiated spurious emissions                                   26
ANNEX B          Receiver radiated spurious emissions                                      28




                            Test Report No.: G0M-1409-4198-TFC209LP-V02
                                        Eurofins Product Service GmbH
                              Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                  Page 4 of 29


1    Equipment (Test item) Description

Description                       Instrument cluster
Model                             Audi FPK Gen1
Additional Model(s)               None
Brand Name(s)                     BOSCH
Serial number                     None
Hardware version                  H33
Software / Firmware version       0215
FCC-ID                            YBN-AU-FPK10
IC                                9595A-AUFPK10
Equipment type                    End product
Radio type                        Transceiver
Radio technology                  custom
Operating frequency range         125 kHz
Frequency range                   FMID                   125 kHz
Modulations                       ASK
Number of channels                1
Channel spacing                   None
Number of antennas                1
                                  Type              integrated
                                  Model             unspecified
Antenna
                                  Manufacturer Biotronik SE & Co. KG
                                  Gain              unspecified
                                  Robert Bosch Car Multimedia GmbH
                                  Robert-Bosch-Straße 200
Manufacturer
                                  31139 Hildesheim
                                  GERMANY
                                  VNOM                   12.0 VDC
Power supply                      VMIN                   N/A
                                  VMIN                   N/A
                                  Model                  N/A
                                  Vendor                 N/A
AC/DC-Adaptor
                                  Input                  N/A
                                  Output                 N/A




                       Test Report No.: G0M-1409-4198-TFC209LP-V02
                                      Eurofins Product Service GmbH
                            Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                Page 5 of 29


1.4        Supporting Equipment Used During Testing


Product
                       Device                   Manufacturer              Model No.        Comments
 Type*
      AE          Comanion Device                    Bosch

      AE             Test Fixture                    Bosch

*Note: Use the following abbreviations:
           AE : Auxiliary/Associated Equipment, or

       SIM : Simulator (Not Subjected to Test)

      CABL : Connecting cables




                                    Test Report No.: G0M-1409-4198-TFC209LP-V02
                                                 Eurofins Product Service GmbH
                                       Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                              Page 15 of 29


1.5     Test Modes


      Mode #                                          Description

                General conditions: EUT powered by laboratory power supply
                Radio conditions:    Mode = standalone transmit
      Single
                                     Modulation = ASK
                                     Power level = Maximum
                General conditions: EUT powered by laboratory power supply
      Receive   Radio conditions:    Mode = standalone receive
                                     Modulation = ASK




                         Test Report No.: G0M-1409-4198-TFC209LP-V02
                                      Eurofins Product Service GmbH
                            Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                Page 16 of 29


  1.6    Test Equipment Used During Testing


                                         Measurement Software
        Description                Manufacturer                         Name                     Version
  EMC Test Software             Dare Instruments                     Radimation                 2014.1.15


                                          Occupied Bandwidth
   Description        Manufacturer          Model               Identifier         Cal. Date       Cal. Due
Spectrum Analyzer        R&S               FSP 30               EF00312            2014-02         2015-02


                                        Field strength emissions
   Description        Manufacturer          Model               Identifier         Cal. Date       Cal. Due
 Semi-anechoic
                       Frankonia             AC 1               EF00062                -               -
   chamber
Spectrum Analyzer        R&S               FSIQ26               EF00242            2014-03         2015-03
  Loop Antenna           R&S              HFH2-Z2               EF00184            2013-10         2014-10




                           Test Report No.: G0M-1409-4198-TFC209LP-V02
                                         Eurofins Product Service GmbH
                               Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                               Page 17 of 29


1.7      Sample emission level calculation

The following is a description of terms and a sample calculation, as appears in the radiated emissions
data table. The numbers used in the calculation are for example only. There is no direct correlation to
the specific data taken for the product described in this document:

Reading:

This is the reading obtained on the spectrum analyzer in dBµV. Any external preamplifiers used are
taken into account through internal analyzer settings.

A.F.:

This is the antenna factor for the receiving antenna. It is a conversion factor, which converts electric
fields strengths to voltages, which can be measured directly on the spectrum analyzer. It is treated as
a loss in dB. Cable losses have been included with the A.F. to simplify the calculations. The antenna
factor is used in calculations as follows:

                 Reading on Analyzer (dBµV) + A.F. (dB) = Net field strength (dBµV/m)

Net:

This is the net field strength measurement (as shown above).

Limit:

This is the FCC Class B radiated emission limit (in units of dBµV/m). The FCC limits are given in units
of µV/m. The following formula is used to convert the units of µV/m to dBµV/m:

                                    Limit (dBµV/m) = 20*log (µV/m)

Margin:

This is the margin of compliance below the FCC limit. The units are given in dB. A negative margin
indicates the emission was below the limit. A positive margin indicates that the emission exceeds the
limit.

Example only:

          Reading + AF      =       Net Reading        :   Net reading - FCC limit = Margin
          21.5 dBµV + 26 dB =       47.5 dBµV/m        :   47.5 dBµV/m - 57.0 dBµV/m = -9.5 dB




                          Test Report No.: G0M-1409-4198-TFC209LP-V02
                                        Eurofins Product Service GmbH
                              Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                          Page 18 of 29


  2     Result Summary


                                      FCC 47 CFR Part 15C, IC RSS-310

  Product Specific                                                  Reference
                                  Requirement – Test                                 Result      Remarks
  Standard Section                                                   Method

      RSS-Gen 4.6.1     Occupied Bandwidth                        RSS-Gen 4.6.1       N/R     Informational only

      FCC 15.201(a),
        FCC 15.209      Field strength emissions                    ANSI C63.4       PASS
      IC RSS-210 2.5
     IC RSS-210 2.3
                        Receiver radiated spurious emissions        ANSI C63.4       PASS
  IC RSS-Gen 4.10 6.1
Remarks:




                             Test Report No.: G0M-1409-4198-TFC209LP-V02
                                           Eurofins Product Service GmbH
                                 Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                Page 19 of 29


  3        Test Conditions and Results

  3.1       Test Conditions and Results – Occupied Bandwidth


Occupied Bandwidth acc. to IC RSS-Gen                                                           Verdict: PASS

             Test according to                                           Reference Method
           measurement reference                                           RSS-Gen 4.6.1
                                                                         Tested frequencies
            Test frequency range
                                                                                 FMID
                  EUT test mode                                                 Single
                                                        Limits
                                              None (Informational only)
                                                      Test setup


                                            Spectrum
                                            Analyzer                          EUT



                                                   Test procedure
      1.   EUT set to test mode (Communication tester is used if needed)
      2.   Span set to at least twice the emission spectrum
      3.   Resolution bandwidth set to 1 % of span
      4.   Occupied Bandwidth (99 %) measurement with spectrum analyzer built in measurement function
                                                     Test results
       Channel             Frequency [kHz]                           Occupied Bandwidth [kHz]
           FMID                   125                                            38.08
Comments: Measurement is applicable to all variants




                                  Test Report No.: G0M-1409-4198-TFC209LP-V02
                                              Eurofins Product Service GmbH
                                    Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                Page 20 of 29


                                    Occupied Bandwidth - FMID
Occupied Bandwidth acc. to RSS-Gen

Project Number: G0M-1409-4198

Applicant:           Robert Bosch Car Multimedia GmbH
EUT Name:
Model:
Test Site:           Eurofins Product Service GmbH
Operator:            Christian Weber
Test Conditions:     Tnom / Vnom
Mode:                Tx, 125 kHz RFID
Test Date:           2014-09-29
Verdict:             NONE (INFORMATION ONLY)
Note 1:              A spectrum analyzer with an integrated 99% power bandwidth function is used
Note 2:              OBW= 38.08 kHz




                         Test Report No.: G0M-1409-4198-TFC209LP-V02
                                      Eurofins Product Service GmbH
                            Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                    Page 21 of 29


  3.2     Test Conditions and Results – Fundamental field strength emissions


Field strength emissions acc. to FCC 47 CFR 15.201 / IC RSS-210                             Verdict: PASS

         Test according referenced                                    Reference Method
                 standards                               FCC 15.201(a) + 15.209 / IC RSS-210 2.5

            Test according to                                         Reference Method
          measurement reference                                          ANSI C63.4
                                                                     Tested frequencies
           Test frequency range                                                    th
                                                                    9 kHz – 10 Harmonic
              EUT test mode                                                  Single
                                                   Limits
 Frequency range [MHz]            Detector        Limit [µV/m]         Limit [dBµV/m]     Limit Distance [m]
        0.009 – 0.490         Quasi-Peak          2400/F[kHz]            48.5 – 13.8             300
        0.490 – 1.705         Quasi-Peak          2400/F[kHz]             13.8 – 1.4             30
         1.705 – 30           Quasi-Peak               30                    29.5                30
          30 – 88             Quasi-Peak               100                    40                  3
          88 – 216            Quasi-Peak               150                   43.5                 3
         216 – 960            Quasi-Peak               200                    46                  3
         960 – 1000           Quasi-Peak               500                    54                  3
           > 1000                 Average              500                    54                  3
The emission limits shown in the above table are based on measurements employing a CISPR quasi-peak
detector except for the frequency bands 9–90 kHz, 110–490 kHz and above 1000 MHz. Radiated emission
limits in these three bands are based on measurements employing an average detector.




                            Test Report No.: G0M-1409-4198-TFC209LP-V02
                                         Eurofins Product Service GmbH
                               Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                            Page 22 of 29


                                                 Test setup



                                             Semi-anechoic Chamber



                                                                                  EUT



                                                                              Turn table


                                                  Ground Plane



                        Amplifier           Measurement
                         Matrix              Receiver

                                             Test procedure

   1. EUT set to test mode
   2. Span it set according to measurement range
   3. Resolution bandwidth below 1 GHz is set according to CISPR 16 with peak/quasi-peak detector
      and RBW of 1 MHz with peak/average detector is used above 1 GHz
   4. Markers are set to maximum emission levels

                                                Test results
            Frequency   Emission        Level
Channel                                                Detector         Limit [dbµV/m]      Margin [dB]
               [kHz]     [kHz]        [dbµV/m]
  FMID        125        35.218         -38.30            avg                36.60            -74.92
  FMID        125       125.265         -12.90            avg                25.70            -38.54
  FMID        125        250.2          -54.40            avg                19.60            -74.01
  FMID        125       375.874         -47.70            avg                16.10            -63.83
  FMID        125         9246          04.20              pk                29.50            -25.34
Comments:




                           Test Report No.: G0M-1409-4198-TFC209LP-V02
                                        Eurofins Product Service GmbH
                              Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                           Page 23 of 29


  3.4     Test Conditions and Results – Receiver radiated emissions


Receiver radiated emissions acc. to IC RSS-210                                                     Verdict: PASS

        Test according referenced                                     Reference Method
                standards                                              IC RSS-210 2.3

           Test according to                                          Reference Method
         measurement reference                                            ANSI C63.4
                                                                      Tested frequencies
          Test frequency range                                                 th
                                                                     9 kHz – 3 Harmonic
             EUT test mode                                                  Receive
                                                     Limits
 Frequency range [MHz]            Detector          Limit [µV/m]          Limit [dBµV/m]         Limit Distance [m]
        0.009 – 0.490            Quasi-Peak         2400/F[kHz]             48.5 – 13.8                 300
        0.490 – 1.705            Quasi-Peak         2400/F[kHz]              13.8 – 1.4                 30
         1.705 – 30              Quasi-Peak              30                     29.5                    30
          30 – 88                Quasi-Peak              100                        40                   3
          88 – 216               Quasi-Peak              150                    43.5                     3
         216 – 960               Quasi-Peak              200                        46                   3
         960 – 1000              Quasi-Peak              500                        54                   3
           > 1000                 Average                500                        54                   3
                                                   Test setup



                                                Semi-anechoic Chamber



                                                                                         EUT



                                                                                    Turn table


                                                     Ground Plane



                          Amplifier            Measurement
                           Matrix               Receiver




                             Test Report No.: G0M-1409-4198-TFC209LP-V02
                                           Eurofins Product Service GmbH
                                 Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                   Page 24 of 29


                                            Test procedure

   1. EUT set to receive mode (Communication tester is used if needed)
   2. Span it set according to measurement range
   3. Resolution bandwidth below 1 GHz is set according to CISPR 16 with peak/quasi-peak detector
      and RBW of 1 MHz with peak/average detector is used above 1 GHz
   4. Markers are set to peak emission levels

                                                Test results
            Frequency   Emission   Emission Level       Emission Level                    Limit       Margin
Channel                                                                          Det.
               [kHz]     [MHz]       [dbµV/m]              [µV/m]                       [dµV/m]       [µV/m]
  FMID        125        18.15            3.0                  1.41              pk      29.5         -28.09
Comments:




                           Test Report No.: G0M-1409-4198-TFC209LP-V02
                                       Eurofins Product Service GmbH
                             Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                Page 25 of 29


  ANNEX A                                    Transmitter radiated spurious emissions
  Spurious emissions according to FCC 15.209

  Project number: G0M-1409-4198

  Applicant:                                                       Robert Bosch Car Multimedia GmbH
  EUT Name:                                                        Instrument cluster
  Model:                                                           Audi FPK Gen1
  Test Site:                                                       Eurofins Product Service GmbH
  Operator:                                                        Weber
  Test Conditions:                                                 Tnom: 25°C, Vnom: 12 VDC (Car battery)
  Antenna:                                                         Rohde & Schwarz HFH 2-Z2
  Measurement distance:                                            3 m converted to 300 m
  Mode:                                                            TX; 125 kHz RFID
  Test Date:                                                       2014-09-29
  Note:                                                            EUT vertical
                                                                                                                                                                     Index 3

                                   FCC 15.209 AV1            FCC 15.209 AV2         FCC 15.209 QP1              RBW: 9 kHz, Vertical Max Average
                                   RBW: 200 Hz, Vertical Max Average          RBW: 200 Hz, Vertical Max Peak



                            60



                            40



                            20
Electrical Field (dBµV/m)




                             0

                                                                                                                        2

                            -20


                                                                          1
                            -40
                                                                                                                                                               3
                                                                                                                                                   4

                            -60



                            -80



                              9k                     20 k          30 k              50 k                      100 k                   200 k           300 k        490 k

                                                                                         Frequency (Hz)




  Frequency                                        Average                        Average Limit                   Average Difference               Average Status
  35.218 kHz                                       -38.3 dBµV/m                   36.6 dBµV/m                     -74.92 dB                        Pass
  125.265 kHz                                      -12.9 dBµV/m                   25.7 dBµV/m                     -38.54 dB                        Pass
  250.2 kHz                                        -54.4 dBµV/m                   19.6 dBµV/m                     -74.01 dB                        Pass
  375.874 kHz                                      -47.7 dBµV/m                   16.1 dBµV/m                     -63.83 dB                        Pass




                                                            Test Report No.: G0M-1409-4198-TFC209LP-V02
                                                                          Eurofins Product Service GmbH
                                                                Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                                          Page 26 of 29


  Spurious emissions according to FCC 15.209

  Project number: G0M-1409-4198

  Applicant:                                                      Robert Bosch Car Multimedia GmbH
  EUT Name:                                                       Instrument cluster
  Model:                                                          Audi FPK Gen1
  Test Site:                                                      Eurofins Product Service GmbH
  Operator:                                                       Weber
  Test Conditions:                                                Tnom: 25°C, Vnom: 12 VDC (Car battery)
  Antenna:                                                        Rohde & Schwarz HFH 2-Z2
  Measurement distance:                                           3 m converted to 30 m
  Mode:                                                           TX; 125 kHz RFID
  Test Date:                                                      2014-09-29
  Note:                                                           EUT vertical
                                                                                                                                             Index 4

                                     FCC 15.209 QP        FCC 15.209 QP2     RBW: 9 kHz, Vertical Max Peak



                            60


                            50


                            40


                            30
Electrical Field (dBµV/m)




                            20


                            10
                                                                                                                       1

                             0


                            -10


                            -20


                            -30




                             490 k                   1M                2M      3M                 5M                    10 M        20 M     30 M

                                                                                 Frequency (Hz)

  Frequency                                          Peak                   Peak Limit                       Peak Difference   Peak Status
  9.246 MHz                                          4.2 dBµV/m             29.5 dBµV/m                      -25.34 dB         Pass




                                                          Test Report No.: G0M-1409-4198-TFC209LP-V02
                                                                        Eurofins Product Service GmbH
                                                              Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                    Page 27 of 29


  ANNEX B                                   Receiver radiated spurious emissions
  Spurious emissions according to RSS-GEN

  Project number: G0M-1409-4198

  Applicant:                                                       Robert Bosch Car Multimedia GmbH
  EUT Name:                                                        Instrument cluster
  Model:                                                           Audi FPK Gen1
  Test Site:                                                       Eurofins Product Service GmbH
  Operator:                                                        Weber
  Test Conditions:                                                 Tnom: 25°C, Vnom: 12 VDC (Car battery)
  Antenna:                                                         Rohde & Schwarz HFH 2-Z2
  Measurement distance:                                            3 m converted to 300 m
  Mode:                                                            TX; 125 kHz RFID Idle
  Test Date:                                                       2014-09-29
  Note:                                                            EUT vertical
                                                                                                                                                           Index 5

                                   FCC 15.209 AV1            FCC 15.209 AV2         RSS-Gen QP1              RBW: 9 kHz, Vertical Max Average
                                   RBW: 200 Hz, Vertical Max Average          RBW: 200 Hz, Vertical Max Peak



                            60



                            40



                            20
Electrical Field (dBµV/m)




                             0



                            -20



                            -40



                            -60



                            -80



                              9k                      20 k          30 k              50 k                     100 k                     200 k   300 k    450 k

                                                                                         Frequency (Hz)




                                                             Test Report No.: G0M-1409-4198-TFC209LP-V02
                                                                          Eurofins Product Service GmbH
                                                                Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                                                  Page 28 of 29


  Spurious emissions according to RSS-GEN

  Project number: G0M-1409-4198

  Applicant:                                                   Robert Bosch Car Multimedia GmbH
  EUT Name:                                                    Instrument cluster
  Model:                                                       Audi FPK Gen1
  Test Site:                                                   Eurofins Product Service GmbH
  Operator:                                                    Weber
  Test Conditions:                                             Tnom: 25°C, Vnom: 12 VDC (Car battery)
  Antenna:                                                     Rohde & Schwarz HFH 2-Z2
  Measurement distance:                                        3 m converted to 30 m
  Mode:                                                        RX; 125 kHz RFID Idle
  Test Date:                                                   2014-09-29
  Note:                                                        EUT vertical
                                                                                                                           Index 6

                                     RSS-Gen QP        RSS-Gen QP2        RBW: 9 kHz, Vertical Max Peak



                            60


                            50


                            40


                            30
Electrical Field (dBµV/m)




                            20


                            10


                             0


                            -10


                            -20


                            -30




                             490 k                1M                 2M          3M                 5M      10 M   20 M    30 M

                                                                                   Frequency (Hz)




                                                         Test Report No.: G0M-1409-4198-TFC209LP-V02
                                                                       Eurofins Product Service GmbH
                                                             Storkower Str. 38c, D-15526 Reichenwalde, Germany
                                                                                                                   Page 29 of 29



Document Created: 2015-02-12 09:54:34
Document Modified: 2015-02-12 09:54:34

© 2024 FCC.report