Test report 15B - report

FCC ID: YBN-AIVIV20

Test Report

Download: PDF
FCCID_4257255

                                               TEST REPORT
                                              No.: 18-1-0239001T01a


                                                            According to:
                                                         FCC Regulations
                                                        Part 15.109, Class B

                                                         ISED-Regulations
                                                          RSS-Gen, Issue 5
                                                         ICES-003, Issue 6



                                                                 for

                                 Robert Bosch Car Multimedia GmbH

                                           AIVIV20
                           Navigationsystem with WLAN and Bluetooth

                                                    FCC-ID: YBN-AIVIV20
                                                    ISED: 9595A- AIVIV20



                                              Laboratory Accreditation and Listings



                                                                                       Voluntary Controls for Electromagnetic
                                                          Industry Canada
                                                                                                    Emissions
                                                         Reg. No.: 3462D-1
                                                         Reg. No.: 3462D-2                          Reg. No.:
                                                         Reg. No.: 3462D-3                      R-4552, C-20009,
             Accredited EMC-Test Laboratory                                                     T-20006, G-20013




                                                                                                MRA US-EU 0003

                                       accredited according to DIN EN ISO/IEC 17025

                                                        CETECOM GmbH
                                Laboratory Radio Communications & Electromagnetic Compatibility
                                            Im Teelbruch 116 • 45219 Essen • Germany
                                   Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                                 Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                     E-mail: info@cetecom.com • Internet: www.cetecom.com


                                              Laboratory Accreditation and Listings




                                                                                                                       Page 1 of 17
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the
written approval of the testing laboratory                                         © Copyright: All rights reserved by CETECOM


Test Report 18-1-0239001T01a, Page 2 of 17


Table of contents
1. SUMMARY OF TEST RESULTS................................................................................................................... 3
  1.1. RX mode, tests overview according FCC Part 15B and Canadian ISED (RSS) Standards .......................... 3
  1.2. Attestation:.................................................................................................................................................... 3
2. ADMINISTRATIVE DATA ............................................................................................................................ 4
  2.1. Identification of the testing laboratory .......................................................................................................... 4
  2.2. Test location ................................................................................................................................................. 4
  2.3. Organizational items ..................................................................................................................................... 4
  2.4. Applicant’s details ........................................................................................................................................ 4
  2.5. Manufacturer’s details .................................................................................................................................. 4
3. EQUIPMENT UNDER TEST (EUT) .............................................................................................................. 5
  3.1. EUT: Type, S/N etc. and short descriptions used in this test report ............................................................. 5
  3.2. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions ............................................................... 5
  3.3. EUT set-ups .................................................................................................................................................. 5
  3.4. EUT operating modes ................................................................................................................................... 6
4. DESCRIPTION OF TEST SYSTEM SET-UP’S ........................................................................................... 7
  4.1. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz ............................................ 7
  4.2. Test system set-up for radiated electric field measurement above 1 GHz .................................................... 8
5. MEASUREMENTS .......................................................................................................................................... 9
  5.1. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz ........................................................... 9
  5.2. General Limit - Radiated emissions, above 1 GHz ..................................................................................... 10
  5.3. Measurement uncertainties ......................................................................................................................... 11
6. ABBREVIATIONS USED IN THIS REPORT ............................................................................................ 12
7. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES .................... 12
8. INSTRUMENTS AND ANCILLARY ........................................................................................................... 13
9. VERSIONS OF TEST REPORTS (CHANGE HISTORY) ........................................................................ 17
END OF TEST REPORT ................................................................................................................................... 17


Table of annex                                                                                                                                        Total pages
SEPARATE ANNEX 1: DIAGRAM OF TESTING “CETECOM_TR18-1-0239001T01a-A1”                                                                                                   6
SEPARATE ANNEX 2: INTERNAL PHOTOGRAPHS OF EUT “Supplied by Customer”
SEPARATE ANNEX 3: EXTERNAL PHOTOGRAPHS OF EUT “CETECOM_TR18-1-0239001T01a-A3” 7
SEPARATE ANNEX 4: TEST SETUP PHOTOGRAPHS “CETECOM_TR18-1-0239001T01a-A4”                                                                                               4
The listed attachments are an integral part of this report.




CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 3 of 17



1. Summary of test results

The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH does not
assume responsibility for any conclusions and generalizations taken in conjunction with other specimens or
samples of the type of the item presented to tests. Also we refer on special conditions which the applicant should
fulfill according §2.927 to §2.948, special focus regarding modification of the equipment and availability of sample
equipment for market surveillance tests.

The Equipment Under Test (in this report, hereinafter referred as EUT) is a Car Radio System with Navigation, WLAN
and Bluetooth technology. A typical operation mode was set-up as described in chapter 3.4 according applicants
instructions.

Following tests have been performed to show compliance with applicable FCC Part 15, Subpart B (Unintentional
Radiators) of the CFR 47 Rules, Edition 2015 and Canadian RSS standards.


1.1. RX mode, tests overview according FCC Part 15B and Canadian ISED (RSS) Standards
    No. of                                                               References & Limits                                            EUT
                                                                                                                          EUT
   Diagram              Test case               Port                                                                                     op-              Result
                                                                                                                         set-up
    group                                                 FCC Standard     RSS Section           Test limit                             mode
                                                                            RSS-132,            FCC 15.109
                        Receiver                                           Issue 3: 6.6        class B limits
                                             Cabinet +      §15.109
                                                                            RSS-Gen,
     3&4                                   Interconnec       §15.33                                                         1              1              Passed
                         radiated                                          Issue 5: 5.3        RSS-Gen:
                                            ting cables      §15.35
                        emissions                                           RSS 133,       Chapter 5.3+Chapter
                                                                           Issue 6: 6.6           7.1.2
Remark:




1.2. Attestation:
I declare that all measurements were performed by me or under my supervision and that all measurements have been performed and are correct to my
best knowledge and belief to Industry Canada standards. All requirements as shown in above table are met in accordance with enumerated standards.




                                                                                                                                  Digital unterschrieben von
                                                                                                                                  B.Sc. Mohamed Ahmed
                                                                                                                                  DN: cn=B.Sc. Mohamed
                                                                                                                                  Ahmed, o=Cetecom
                                                                                                                                  GmbH, ou=RC/EMC,
                                                                                                                                  email=mohamed.ahmed@
                                                                                                                                  cetecom.com, c=DE
                                                                                                                                  Datum: 2018.12.28
                                                                                                                                  13:27:52 +01'00'


......................................................                                             ....................................................
Dipl.-Ing. Niels Jeß                                                                                            B.Sc. Mohamed Ahmed
Responsible for test section                                                                                 Responsible for test report




CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 4 of 17


2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                        CETECOM GmbH
Address:                                                             Im Teelbruch 116
                                                                     45219 Essen - Kettwig
                                                                     Germany
Responsible for testing laboratory:                                  Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                        see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Responsible for test report:                                         B.Sc. M. Ahmed

project leader:                                                      Dipl.-Ing N. Perez
Receipt of EUT:                                                      2018-11-30
Date(s) of test:                                                     2018-12-17 – 2018-12-21
Date of report:                                                      2018-12-28
           -----------------------------------------------------------------------------------------------------------------------------------------------------

Version of template:            13.02

2.4. Applicant’s details

Applicant’s name:                                                    Robert Bosch Car Multimedia GmbH
Address:                                                             Robert-Bosch-Straße 200
                                                                     31139 Hildesheim

                                                                     Germany
Contact person:                                                      Mr. Salvatore Mirgalia

2.5. Manufacturer’s details

Manufacturer’s name:                                                 Robert Bosch Car Multimedia Portugal, S.A.

Address:                                                             Rua Max Grundig, 35-Lomar
                                                                     4705-820 Braga

                                                                     Portugal




CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 5 of 17


3. Equipment under test (EUT)

3.1. EUT: Type, S/N etc. and short descriptions used in this test report
Short
                                                                   S/N                 HW                  SW
descrip-              EUT                    Type
                                                              serial number       hardware status     software status
tion*)

  EUT A                               Navigationsystem
                   AIVIV20            with WLAN and             0005021             Version D         283C373820R
    S06                                  Bluetooth
*) EUT short description is used to simplify the identification of the EUT in this test report.


3.2. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions
    AE
                                                                      S/N                HW                 SW
   short     Auxiliary Equipment               Type
                                                                 serial number      hardware status    software status
 descrip-
  tion *)
  AE 1         P-IVI USB Box                 USB Box                   --                 --                  --

             P-IVI LVDS-Video-
  AE 2                                   Video-Generator               --                 --                  --
                Generator#02

  AE 3            RF Splitter                    --                    --                 --                  --

              Load Box PIVI +2
  AE 4                                           --                    --                 --                  --
               Meter Harness

              RJ 45 Dual Audio-         Dual Audio-Video
  AE 5                                                                 --                 --                  --
                 Video Balun                 Balun

              RJ 45 Quad Audio-
  AE 6                                  Quad Audio-Balun               --                 --                  --
                    Balun
*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.




3.3. EUT set-ups

 EUT set-up
                       Combination of EUT and AE                                       Remarks
   no.*)

                 EUT A + AE 1 + AE 2 + AE 3 + AE 4 +
    set. 1                                                                  Used for radiated measurements.
                            AE 5 + AE 6
*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.




CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 6 of 17

3.4. EUT operating modes

    EUT
                 Description of
  operating                                                Additional information
                operating modes
 mode no.*)

               CAN + GPS and
    op. 1                                   CAN + Broadcasting receiver (FM/ AM) and GPS activated
              broadcast RX mode
EUT operating mode no. is used to simplify the test report.




CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 7 of 17


4. Description of test system set-up’s
4.1. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz

 Specification:              ANSI C63.4-2014 chapter 8, ANSI C63.10-2013 chapter 6.5

 General Description:        Evaluating the field emissions have to be done first by an exploratory emissions
                             measurement and a final measurement for most critical frequencies. The tests are
                             performed in a NSA-compliant semi anechoic room (SAR) recognized by the
                             regulatory commissions.

 Schematic:




 Testing method:             Exploratory, preliminary measurements                Final measurement on critical frequencies
                             The EUT and its associated accessories are placed    Based on the exploratory measurements, the most
                             on a non-conductive position manipulator (tipping    critical frequencies are re-measured by main-
                             device) of 0.8 m height which is placed on the       taining the EUT’s worst-case operation mode, cable
                             turntable. By rotating the turntable (range 0° to    position, etc.
                             360°, step 90°) and the EUT itself either on 3-
                             orthogonal axis (portable equipment) or 2-           First a frequency zoom around the critical frequency
                             orthogonal axis (defined operational position of     is done to locate the frequency more precisely. After
                             EUT) the emission spectrum and it’s                  this step, for all identified critical frequencies, the
                             characteristics was recorded with an EMI-            maximum peak was determined.
                             receiver, broadband antenna and software.
                                                                                  Following parameters were varied: the turntable
                             Measurement antenna: horizontal and vertical,        angle continuously in the range 0 to 360 degree, the
                             heights: 1,0 m and 1,82 m as worst-case              EUT itself either over 3-orthogonal axis (not
                             determined by an exploratory emission                defined usage position) or 2-orthogonal axis
                             measurements. The results are documented in a        (defined usage position). The measurement antenna
                             diagram. Critical frequencies (low margin to         height between 1 m and 4 m.
                             limit) are saved within a table for further
                             investigations. If various operating modes are       On the determined worst-case position, a final
                             supported, further investigations are made to find   measurement with necessary bandwidth and
                             the worst-case of them. Also the interconnection     detector according standard has been carried out.
                             cables and equipment position were varied in
                             order to maximize the emissions.

 Formula:                    EC = ER + AF + CL + DF - GA (1)           AF = Antenna factor
                                                                       CL = Cable loss
                             M = LT - EC         (2)                   DF = Distance correction factor (if used)
                                                                       EC = Electrical field – corrected value
                                                                       ER = Receiver reading
                                                                       GA = Gain of pre-amplifier (if used)
                                                                       LT = Limit
                                                                       M = Margin
                             All units are dB-units, positive margin means value is below limit.




CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 8 of 17

4.2. Test system set-up for radiated electric field measurement above 1 GHz

 Specification:              ANSI C63.4-2014 chapter 8, ANSI C63.10-2013 chapter 6.6

 General Description:        Evaluating the field emissions have to be done first by an exploratory emissions
                             measurement and a final measurement for most critical frequencies. The tests are
                             performed in a CISPR 16-4 compliant fully anechoic room (FAR) recognized by
                             the regulatory commissions. The measurement distance was set to 3 meter for
                             frequencies up to 18 GHz and 2 meter above 18 GHz. A bicon-log or horn antenna
                             is used for frequency range 1 GHz to 40 GHz. Due to use of a fully anechoic room
                             the measurement antennas are set to fixed antenna height of 1.55 m and the site
                             validation criteria accord. CISPR 16-1-4:2010, Chapter 8.3 is fulfilled. The EUT is
                             aligned within 3 dB beamwidth of the measurement antenna, on big EUTs several
                             surface measurements are performed.

 Schematic:




 Testing method:             Exploratory, preliminary measurements                Final measurement on critical frequencies
                             The EUT and its associated accessories are placed    Based on the exploratory measurements, the most
                             on a non-conductive position manipulator (tipping    critical frequencies are re-measured by main-
                             device) of 1.55 m height which is placed on the      taining the EUT’s worst-case operation mode,
                             turntable. By rotating the turntable (range 0° to    cable position, etc.
                             360°, step 15°) and the EUT itself either on 3-
                             orthogonal axis (portable equipment) or 2-           First a frequency zoom around the critical
                             orthogonal axis (defined operational position of     frequency is done to locate the frequency more
                             EUT) the emission spectrum and it’s                  precisely. After this step, for all identified critical
                             characteristics was recorded with an EMI-            frequencies, the maximum peak was determined.
                             receiver, broadband antenna and software.
                             The measurements are performed in horizontal         Following parameters were varied: the turntable
                             and vertical polarization of the measurement         angle continuously in the range 0 to 360 degree,
                             antennas. The results are documented in a            the EUT itself either over 3-orthogonal axis (not
                             diagram. Critical frequencies (low margin to         defined usage position) or 2-orthogonal axis
                             limit) are saved within a table for further          (defined usage position). The measurement
                             investigations. If various operating modes are       antenna height is fixed to 1.55 m.
                             supported, further investigations are made to find
                             the worst-case of them. Also the interconnection     On the determined worst-case position, a final
                             cables and equipment position were varied in         measurement with necessary bandwidth and
                             order to maximize the emissions.                     detector according standard has been carried out.

 Formula:                    EC = ER + AF + CL + DF - GA (1)           EC = Electrical field – corrected value
                                                                       ER = Receiver reading
                             M = LT - EC         (2)                   M = Margin
                                                                       LT = Limit
                                                                       AF = Antenna factor
                                                                       CL = Cable loss
                                                                       DF = Distance correction factor (if used)
                                                                       GA = Gain of pre-amplifier (if used)
                             All units are dB-units, positive margin means value is below limit.




CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 9 of 17


5. Measurements
5.1. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz
5.1.1. Test location and equipment
test location      CETECOM Essen (Chapter. 2.2.1)            Please see Chapter. 2.2.2                 Please see Chapter. 2.2.3
test site          441 EMI SAR  487 SAR NSA
receiver           377 ESCS30     001 ESS                   489 ESU 40          620 ESU 26
spectr. analys.    584 FSU        120 FSEM                  264 FSEK
antenna            574 BTA-L      133 EMCO3115              302 BBHA9170        289    CBL 6141       030 HFH-Z2  477 GPS
signaling          392 MT8820A  371 CBT32                   547 CMU             594    CMW
otherwise          400 FTC40x15E  401 FTC40x15E             110 USB LWL         482    Filter Matrix
DC power           456 EA 3013A  457 EA 3013A               459 EA 2032-50      268    EA- 3050       494 AG6632A  498 NGPE
Supply Voltage     via laptop                                13.5VDC

5.1.2. Requirements/Limits
                    FCC
                                                  Part 15 Subpart B, §15.109, class B
                                                  Part 15 Subpart C, §15.209 @ frequencies defined in §15.205
                                                  RSS-Gen., Issue 5, Chapter 8.9, Table 5+7 (license-exempt radio apparatus)
                                                  RSS-Gen., Issue 5, Chapter 7.1.2, Table 4 (receiver)
                    ISED
                                                  ICES-003, Issue 6, Table 5 (Class B)
                                                  RSS-247, Issue 1, Chapter 5 (DTS2.4GHZ Band)
                                                  C63.4-2014
                    ANSI
                                                  C63.10-2013
                                                                          Radiated emissions limits, 3 meters
                     Frequency [MHz]
                                                            QUASI Peak [µV/m]                          QUASI-Peak [dBµV/m]
                          30 - 88                                 100                                         40.0
     Limit
                          88 - 216                                150                                         43.5
                         216 - 960                                200                                         46.0
                         above 960                                500                                         54.0


5.1.3. Test condition and measurement test set-up
Signal link to test system (if used):          air link      cable connection         none
 EUT-grounding                                 none          with power supply  additional connection
 Equipment set up                              table top 0.8m height                  floor standing
 Climatic conditions                          Temperature: (22±3°C)                   Rel. humidity: (40±20)%
 EMI-Receiver         Scan frequency range:    30 – 1000 MHz  other:
(Analyzer) Settings Scan-Mode                  6 dB EMI-Receiver Mode  3 dB spectrum analyser mode
                      Detector                Peak / Quasi-peak
                      RBW/VBW                 100 kHz/300 kHz
                      Mode:                   Repetitive-Scan, max-hold
                      Scan step               80 kHz
                      Sweep-Time              Coupled – calibrated display if continuous tx-signal otherwise adapted to EUT’s individual
                                              duty-cycle
 General measurement procedures               Please see chapter “Test system set-up for electric field measurement in the range 30 MHz
                                               to 1 GHz”

5.1.4. MEASUREMENT RESULTS
The results are presented below in summary form only. For more information please see diagrams.
Table of measurement results:

   Dia-                                  Set-             OP-                                        Used detector              Result
   gram        Frequency range            up              mode                 Remark
    no.                                  no.               no.
                                                                                                   PK       AV      QP

   3.01a      30 MHz – 1 GHz            Set. 1            Op. 1              EUT laying                                      passed

   3.01b      30 MHz – 1 GHz            Set. 1            Op. 1             EUT standing                                     passed

Remark: --




CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 10 of 17

5.2. General Limit - Radiated emissions, above 1 GHz
5.2.1. Test location and equipment FAR
test site           441   EMI SAR        348   EMI cond.     443   EMI FAR         347   Radio.lab.  337 OATS           
spectr. analys.     584   FSU            120   FSEM          264   FSEK            489   ESU 40                         
antenna meas        574   BTA-L          289   CBL 6141      608   HL 562          549   HL025       302 BBHA9170        477 GPS
antenna meas        123   HUF-Z2         132   HUF-Z3        030   HFH-Z2          376   BBHA9120E                       
antenna subst       071   HUF-Z2         020   EMCO3115      063   LP 3146         303   BBHA9170                       
multimeter          341   Fluke 112                                                                                     
signaling           392   MT8820A        371   CBT32         547   CMU             594   CMW
DCpower             086   LNG50-10       087   EA3013        354   NGPE 40         349   car battery 350 Car battery    
Supply
                    via laptop                                13.5VDC
Voltage

5.2.2. Requirements/Limits
                                Part 15 Subpart B, §15.109 class B
            FCC                 Part 15 Subpart C, §15.209 for frequencies defined in §15.205
                                Part 15 Subpart C, §15.407(b)(1)(2)(3)(4)

                                RSS-Gen., Issue 5, Chapter 8.9, Table 5+7 (transmitter licence excempt)
                                RSS-Gen., Issue 5, Chapter 8.9, Table 3 (receiver)
            ISED
                                ICES-003, Issue 6, Chapter 6.2.2, Table 7 (class B)
                                RSS-247, Issue 2, Chapter 6

                                C63.4-2014
            ANSI
                                C63.10-2013
                                                                                        Limits
        Frequency                            AV                            AV                      Peak                       Peak
          [MHz]                            [µV/m]                       [dBµV/m]                  [µV/m]                   [dBµV/m] or
                                                                                                                           [dBm/MHz]
      above 1 GHz
   for frequencies as
   defined in §15.205
                                            500                            54.0                    5000                    74.0 dBµV/m
           or
   RSS-Gen., Issue 5,
    §8.10 - Table 5

5.2.3. Test condition and measurement test set-up
 Signal link to test system (if used):             air link      cable connection       none
 EUT-grounding                                     none          with power supply  additional connection
 Equipment set up                                  table top 1.5m height                 floor standing
 Climatic conditions                              Temperature: (22±3°C)                  Rel. humidity: (40±20)%
Spectrum- Scan frequency range:                    1 – 18 GHz  18 – 25 GHz  18 – 40 GHz  other:
Analyzer      Scan-Mode                            6 dB EMI-Receiver Mode  3 dB Spectrum analyser Mode
settings      Detector                            Peak and Average
              RBW/VBW                             1 MHz / 3 MHz
              Mode:                               Repetitive-Scan, max-hold
              Scan step                           400 kHz
              Sweep-Time                          Coupled – calibrated display if CW signal otherwise adapted to EUT’s individual duty-cycle
General measurement procedures                    Please see chapter “Test system set-up for radiated electric field measurements above 1 GHz”

5.2.4. Measurement Results

The results are presented below in summary form only. For more information please see diagrams.

                                   Set-           OP-                                                      Used detector           Result
  Diagram         Frequency
                                    up            mode                     Remark
    no.             range
                                   no.             no.
                                                                                                      PK       AV      QP

    4.01a         1 – 18 GHz      Set. 1          Op. 1                         --                                              passed


   4.01b          18 – 26GHz      Set. 1          Op. 1                         --                                              passed

Remark: --




CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 11 of 17

5.3. Measurement uncertainties

The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate coverage factor
k, such that a confidence level of approximately 95% is achieved.
For uncertainty determination, each component used in the concrete measurement set-up was taken in account and it’s
contribution to the overall uncertainty according it’s statistical distribution calculated.

Following table shows expectable uncertainties for each measurement type performed.

                                                                          Calculated uncertainty based on a
     RF-Measurement            Reference         Frequency range                                                        Remarks
                                                                              confidence level of 95%
 Conducted emissions                            9 kHz - 150 kHz                        4.0 dB
                             CISPR 16-2-1                                                                                  -
 (U CISPR)                                     150 kHz - 30 MHz                        3.6 dB
 Radiated emissions                             30 MHz - 1 GHz                         4.2 dB
                             CISPR 16-2-3                                                                               E-Field
 Enclosure                                      1 GHz - 18 GHz                         5.1 dB
 Disturbance power           CISPR 16-2-2      30 MHz - 300 MHz       -                                                    -
                                                                                                                   Substitution
 Power Output radiated              -         30 MHz - 4 GHz                           3.17 dB
                                                                                                                   method
                                                                       Cel-   Cel-
                                              Set-up No.                             BT1     W1     W2        --
                                                                        C1     C2
 Power Output conducted             -          9 kHz - 12.75 GHz       N/A    0.60    0.7 0.25      N/A       --           -
                                                12.75 - 26.5GHz        N/A    0.82     --    N/A    N/A       --
 Conducted emissions                -           9 kHz - 2.8 GHz        0.70   N/A    0.70 N/A       0.69      --    N/A - not
 on RF-port                                   2.8 GHz - 12.75GHz       1.48   N/A    1.51 N/A       1.43      --    applicable
                                              12.75 GHz - 18GHz        1.81   N/A    1.83 N/A       1.77      --
                                               18 GHz - 26.5GHz        1.83   N/A    1.85 N/A       1.79      --
 Power density                      -             1 – 2.8GHz                            1.40 dB                    --
                                                                              0.1272 ppm (Delta Marker)            Frequency
 Occupied bandwidth                 -             9 kHz - 4 GHz                                                    error
                                                                                       1.0 dB                      Power
                                    -                                         0.1272 ppm (Delta Marker)            Frequency
 Emission bandwidth                               9 kHz - 4 GHz                                                    error
                                    -                                            See above: 0.70 dB                Power
 Frequency stability                -           9 kHz - 20 GHz                      0.0636 ppm                           -
                                               150 kHz - 30 MHz                        5.0 dB                      Magnetic
 Radiated emissions                             30 MHz - 1 GHz                         4.2 dB                      field
                                    -
 Enclosure                                      1 GHz - 20 GHz                        3.17 dB                      E-field
                                                                                                                   Substitution
Table: measurement uncertainties, valid for conducted/radiated measurements




CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 12 of 17


6. Abbreviations used in this report
 The abbreviations
 ANSI                    American National Standards Institute
 AV , AVG, CAV           Average detector
 EIRP                    Equivalent isotropically radiated power, determined within a separate measurement
 EGPRS                   Enhanced General Packet Radio Service
 EUT                     Equipment Under Test
 FCC                     Federal Communications Commission, USA
 IC                      Industry Canada
 n.a.                    not applicable
 Op-Mode                 Operating mode of the equipment
 PK                      Peak
 RBW                     resolution bandwidth
 RF                      Radio frequency
 RSS                     Radio Standards Specification, Dokuments from Industry Canada
 Rx                      Receiver
 TCH                     Traffic channel
 Tx                      Transmitter
 QP                      Quasi peak detector
 VBW                     Video bandwidth
 ERP                     Effective radiated power




7. Accreditation details of CETECOM’s laboratories and test sites

 Ref.-   Accreditation                  Valid for laboratory area or test site
 No.      Certificate                                                                               Accreditation Body
 -          D-PL-                                                                             DAkkS, Deutsche
                         All laboratories and test sites of CETECOM GmbH, Essen
         12047-01-01                                                                          Akkreditierungsstelle GmbH
 337                 Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
 487                 Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)                         FCC, Federal Communications
      (MRA US-EU
 558                 Radiated Measurements above 1 GHz, 3 m (FAR)                             Commission
          0003)
 348                 Mains Ports Conducted Interference Measurements                          Laboratory Division, USA
 348                 Telecommunication Ports Conducted Interference Measurem.
 337    3462D-1      Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
 487    3462D-2      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)                         IC, Industry Canada Certification
 550    3462D-2      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)                          and Engineering Bureau
 558    3462D-3      Radiated Measurements above 1 GHz, 3 m (FAR)
 487    R-20013      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                              VCCI, Voluntary Control Council
 550    G-20013      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                              for Interference by Information
 348    C-20009      Mains Ports Conducted Interference Measurements
                                                                                              Technology Equipment, Japan
 348     T-20006     Telecommunication Ports Conducted Interference Measurem.
 OATS = Open Area Test Site, SAR = Semi Anechoic Room, FAR = Fully Anechoic Room




CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 13 of 17


8. Instruments and Ancillary
the left column of the following tables allows the clear identification of the laboratory equipment.


8.1.1. Test software and firmware of equipment
 Ref.-No.




                           Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


001         EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
012         Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
013         Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
017         Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
053         Audio Analyzer                            UPA3                     860612/022          Firm. V 4.3
119         RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
140         Signal Generator                          SMHU                     831314/006          Firm.= 3.21
261         Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
262         Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
263         Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
                                                                                                   UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
295         Racal Digital Radio Test Set              6103                     1572
                                                                                                   SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                   R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
298         Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                   all band used
323         Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
335         CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
340         Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
355         Power Meter                               URV 5                    891310/027          Firm.= 1.31
365         10V Insertion Unit 50 Ohm                 URV5-Z2                  100880              Eprom Data = 31.03.08
366         Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
371         Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
377         EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
378         Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
389         Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                   Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
392         Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                   4.52#002
                                                                                                   R&S Test Firmware Base=5.14, Mess-Software=
436         Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                   GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
441         CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
442         CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                      System CTC-FAR-EMI-
443         CTC-FAR-EMI-RSE                                                    -                   Spuri 7.2.5 or EMC 32 Ver. 9.15.00
                                                      RSE
444         CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 9.15.00
                                                                                                   R&S Test Firmware Base=5.14, GSM=5.14
460         Univ. Radio Communication Tester          CMU 200                  108901
                                                                                                   WCDMA=5.14 (current Testsoftw.,f. all band to be used,
489         EMI Test Receiver                         ESU40                    1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
491         ESD Simulator dito                        ESD dito                 dito307022          V 2.30
524         Voltage Drop Simulator                    VDS 200                  0196-16             Software Nr: 000037 Version V4.20a01
526         Burst Generator                           EFT 200 A                0496-06             Software Nr. 000034 Version V2.32
527         Micro Pulse Generator                     MPG 200 B                0496-05             Software-Nr. 000030 Version V2.43
528         Load Dump Simulator                       LD 200B                  0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                                   R&S Test Firmware Base=5.14, GSM=5.14
546         Univ. Radio Communication Tester          CMU 200                  106436
                                                                                                   WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                   R&S Test Firmware Base=V5.1403 (current Testsoftw.,
547         Univ. Radio Communication Tester          CMU 200                  835390/014
                                                                                                   f. all band used, GSM = 5.14 WCDMA: = 5.14
584         Spectrum Analyzer                         FSU 8                    100248              2.82_SP3
                                                                                                   R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
597         Univ. Radio Communication Tester          CMU 200                  100347
                                                                                                   not installed, Mainboard= µP1=V.850
598         Spectrum Analyzer                         FSEM 30                  831259/013          Firmware Bios 3.40 , Analyzer 3.40 Sp 2
607         Signal Generator                          SMR 20                   832033/011          V1.25
620         EMI Test Receiver                         ESU 26                   100362              4.43_SP3
642         Wideband Radio Communication Tester       CMW 500                  126089              Setup V03.26, Test programm component V03.02.20
670         Univ. Radio Communication Tester          CMU 200                  106833              µP1 =V8.50, Firmware = V.20
689         Vector Signal Generator                   SMU200                   100970              02.20.360.142
                                                                                                   CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
692         Bluetooth Tester                          CBT 32                   100236
                                                                                                   RF)




CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 14 of 17

8.1.2. Single instruments and test systems
 Ref.-No.




                                                                                                                           calibration
                                                                                                                           Interval of



                                                                                                                                             Remark
                          Equipment                        Type                    Serial-No.          Manufacturer                                      Cal
                                                                                                                                                         due

 001        EMI Test Receiver                      ESS                    825132/017               Rohde & Schwarz         12 M          -            16.05.2019
 005        AC - LISN (50 Ohm/50µH, test site 1)   ESH2-Z5                861741/005               Rohde & Schwarz         12 M          -            16.05.2019
 007        Single-Line V-Network (50 Ohm/5µH)     ESH3-Z6                892563/002               Rohde & Schwarz         12 M          -            16.05.2019
 009        Power Meter (EMS-radiated)             NRV                    863056/017               Rohde & Schwarz         24 M          -            15.05.2019
 016        Line Impedance Simulating Network      Op. 24-D               B6366                    Spitzenberger+Spies     36 M          -            30.05.2019
                                                                                                                           36/12
 020        Horn Antenna 18 GHz (Subst 1)          3115                   9107-3699                EMCO                                  -            31.07.2021
                                                                                                                           M
 021        Loop Antenna (H-Field)                 6502                   9206-2770                EMCO                    36 M          -            30.05.2021
 033        RF-current probe (100kHz-30MHz)        ESH2-Z1                879581/18                Rohde & Schwarz         24 M          -            15.05.2019
 057        relay-switch-unit (EMS system)         RSU                    494440/002               Rohde & Schwarz         pre-m         1a
 060        power amplifier (DC-2kHz)              PAS 5000               B6363                    Spitzenberger+Spies     -             3
 086        DC - power supply, 0 -10 A             LNG 50-10              -                        Heinzinger Electronic   pre-m         2
 087        DC - power supply, 0 -5 A              EA-3013 S              -                        Elektro Automatik       pre-m         2
 091        USB-LWL-Converter                      OLS-1                  007/2006                 Ing. Büro Scheiba       -             4
 099        passive voltage probe                  ESH2-Z3                299.7810.52              Rohde & Schwarz         36 M          -            30.05.2021
 100        passive voltage probe                  Probe TK 9416          without                  Schwarzbeck             36 M          -            30.05.2021
 110        USB-LWL-Converter                      OLS-1                  -                        Ing. Büro Scheiba       -             4
            RT Harmonics Analyzer dig.
 119                                               B10                    G60547                   BOCONSULT               36 M          -            30.05.2019
            Flickermeter
 133        horn antenna 18 GHz (Meas 1)           3115                   9012-3629                EMCO                    36 M          1c           10.03.2020
 134        horn antenna 18 GHz (Subst 2)          3115                   9005-3414                EMCO                    36 M          -            10.03.2020
 248        attenuator                             SMA 6dB 2W             -                        Radiall                 pre-m         2
 249        attenuator                             SMA 10dB 10W           -                        Radiall                 pre-m         2
 252        attenuator                             N 6dB 12W              -                        Radiall                 pre-m         2
 256        attenuator                             SMA 3dB 2W             -                        Radiall                 pre-m         2
 257        hybrid                                 4031C                  04491                    Narda                   pre-m         2
 260        hybrid coupler                         4032C                  11342                    Narda                   pre-m         2
 261        Thermal Power Sensor                   NRV-Z55                825083/0008              Rohde & Schwarz         24 M          -            30.05.2020
 262        Power Meter                            NRV-S                  825770/0010              Rohde & Schwarz         24 M          -            30.05.2019
 263        Signal Generator                       SMP 04                 826190/0007              Rohde & Schwarz         36 M          -            30.05.2019
 265        peak power sensor                      NRV-Z33, Model 04      840414/009               Rohde & Schwarz         24 M          -            30.05.2020
 266        Peak Power Sensor                      NRV-Z31, Model 04      843383/016               Rohde & Schwarz         24 M          -            30.05.2020
                                                   WRCA 800/960-
 267        notch filter GSM 850                                          9                        Wainwright GmbH         pre-m         2
                                                   6EEK
 270        termination                            1418 N                 BB6935                   Weinschel               pre-m         2
 271        termination                            1418 N                 BE6384                   Weinschel               pre-m         2
 272        attenuator (20 dB) 50 W                Model 47               BF6239                   Weinschel               pre-m         2
 273        attenuator (10 dB) 100 W               Model 48               BF9229                   Weinschel               pre-m         2
                                                   Model 47 (10 dB) 50
 274        attenuator (10 dB) 50 W                                       BG0321                   Weinschel               pre-m         2
                                                   W
 275        DC-Block                               Model 7003 (N)         C5129                    Weinschel               pre-m         2
 276        DC-Block                               Model 7006 (SMA)       C7061                    Weinschel               pre-m         2
 279        power divider                          1515 (SMA)             LH855                    Weinschel               pre-m         2
 298        Univ. Radio Communication Tester       CMU 200                832221/091               Rohde & Schwarz         pre-m         3
 300        AC LISN (50 Ohm/50µH, 1-phase)         ESH3-Z5                892 239/020              Rohde & Schwarz         12 M          -            17.05.2019
 301        attenuator (20 dB) 50W, 18GHz          47-20-33               AW0272                   Lucas Weinschel         pre-m         2
 302        horn antenna 40 GHz (Meas 1)           BBHA9170               155                      Schwarzbeck             36 M          -            14.03.2020
 303        horn antenna 40 GHz (Subst 1)          BBHA9170               156                      Schwarzbeck             36 M          -            20.03.2020
 331        Climatic Test Chamber -40/+180 Grad    HC 4055                43146                    Heraeus Vötsch          24 M          -            30.10.2019
 341        Digital Multimeter                     Fluke 112              81650455                 Fluke                   24 M          -            30.05.2020
 342        Digital Multimeter                     Voltcraft M-4660A      IB 255466                Voltcraft               24 M          -            17.05.2019
 347        laboratory site                        radio lab.             -                        -                       -             5
 348        laboratory site                        EMI conducted          -                        -                       -             5
 354        DC - Power Supply 40A                  NGPE 40/40             448                      Rohde & Schwarz         pre-m         2
 357        power sensor                           NRV-Z1                 861761/002               Rohde & Schwarz         24 M          -            24.05.2019
 371        Bluetooth Tester                       CBT32                  100153                   R&S                     36 M          -            30.05.2019
 373        Single-Line V-Network (50 Ohm/5µH)     ESH3-Z6                100535                   Rohde & Schwarz         12 M          -            17.05.2019
 377        EMI Test Receiver                      ESCS 30                100160                   Rohde & Schwarz         12 M          -            30.05.2019
 389        Digital Multimeter                     Keithley 2000          0583926                  Keithley                pre-m         -
 392        Radio Communication Tester             MT8820A                6K00000788               Anritsu                 12 M          -            30.06.2019
                                                                                                   LUFFT Mess u.
 405        Thermo-/Hygrometer                     OPUS 10 THI            126.0604.0003.3.3.3.22                           24 M          -            30.03.2019
                                                                                                   Regeltechnik GmbH
 431        Model 7405                             Near-Field Probe Set   9305-2457                EMCO                    -             4
 436        Univ. Radio Communication Tester       CMU 200                103083                   Rohde & Schwarz         12 M          -            06.03.2019
 439        UltraLog-Antenna                       HL 562                 100248                   Rohde & Schwarz         36 M          -            10.03.2020
 454        Oscilloscope                           HM 205-3               9210 P 29661             Hameg                   -             4
 456        DC-Power supply 0-5 A                  EA 3013 S              207810                   Elektro Automatik       pre-m         2
 459        DC -Power supply 0-5 A , 0-32 V        EA-PS 2032-50          910722                   Elektro Automatik       pre-m         2
 460        Univ. Radio Communication Tester       CMU 200                108901                   Rohde & Schwarz         12 M          -            30.05.2019
 463        Universal source                       HP3245A                2831A03472               Agilent                 -             4
 466        Digital Multimeter                     Fluke 112              89210157                 Fluke USA               24 M          -            30.05.2020


CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 15 of 17
 Ref.-No.




                                                                                                                           calibration
                                                                                                                           Interval of



                                                                                                                                             Remark
                            Equipment                        Type                     Serial-No.           Manufacturer                                  Cal
                                                                                                                                                         due

 467        Digital Multimeter                       Fluke 112              89680306                 Fluke USA             36 M          -            30.05.2019
 468        Digital Multimeter                       Fluke 112              90090455                 Fluke USA             36 M          -            30.04.2021
                                                                                                     Automotive Cons.
 477        ReRadiating GPS-System                   AS-47                  -                                              -             3
                                                                                                     Fink
 480        power meter (Fula)                       NRVS                   838392/031               Rohde & Schwarz       24 M          -            16.05.2019
 482        filter matrix                            Filter matrix SAR 1    -                        CETECOM (Brl)         -             1d
            System CTC NSA-Verification SAR-         System EMI field                                ETS Lindgren /
 487                                                                        -                                              24 M          -            31.03.2019
            EMI                                      (SAR) NSA                                       CETECOM
 489        EMI Test Receiver                        ESU40                  1000-30                  Rohde & Schwarz       12 M          -            30.06.2019
                                                     WRCG 1709/1786-
 502        band reject filter                                              SN 9                     Wainwright            pre-m         2
                                                     1699/1796-
                                                     WRCG 824/849-
 503        band reject filter                                              SN 5                     Wainwright            pre-m         2
                                                     814/859-60/10SS
                                                     HF Relais Box
 517        relais switch matrix                                            SE 04                    Keithley              pre-m         2
                                                     Keithley System
 523        Digital Multimeter                       L4411A                 MY46000154               Agilent               24 M          -            18.05.2019
 529        6 dB Broadband resistive power divider   Model 1515             LH 855                   Weinschel             pre-m         2
            10 dB Broadband resistive power
 530                                                 R 416110000            LOT 9828                 -                     pre-m         2
            divider
 546        Univ. Radio Communication Tester         CMU 200                106436                   R&S                   12 M          -            30.07.2019
 547        Univ. Radio Communication Tester         CMU 200                835390/014               Rohde & Schwarz       12 M          -            30.07.2019
                                                                                                                           36/12
 549        Log.Per-Antenna                          HL025                  1000060                  Rohde & Schwarz                     -            31.07.2021
                                                                                                                           M
            System CTC S-VSWR Verification           System EMI Field                                ETS
 550                                                                        -                                              24 M          -            30.03.2019
            SAR-EMI                                  SAR S-VSWR                                      Lindgren/CETECOM
                                                     System CTC FAR S-
 558        System CTC FAR S-VSWR                                           -                        CTC                   24 M          -            08.08.2019
                                                     VSWR
                                                                                                                           36/12
 574        Biconilog Hybrid Antenna                 BTA-L                  980026L                  Frankonia                           -            31.03.2019
                                                                                                                           M
 584        Spectrum Analyzer                        FSU 8                  100248                   Rohde & Schwarz       pre-m         -
 594        Wideband Radio Communication Tester      CMW 500                101757                   Rohde & Schwarz       12 M          -            30.05.2019
 597        Univ. Radio Communication Tester         CMU 200                100347                   Rohde & Schwarz       pre-m         -
 600        power meter                              NRVD (Reserve)         834501/018               Rohde & Schwarz       24 M          -            17.05.2019
 601        medium-sensitivity diode sensor          NRV-Z5 (Reserve)       8435323/003              Rohde & Schwarz       24 M          -            15.05.2019
 602        peak power sensor                        NRV-Z32 (Reserve)      835080                   Rohde & Schwarz       24 M          -
 611        DC power supply                          E3632A                 KR 75305854              Agilent               pre-m         2
 612        DC power supply                          E3632A                 MY 40001321              Agilent               pre-m         2
                                                     R416120000 20dB
 613        Attenuator                                                      Lot. 9828                Radiall               pre-m         2
                                                     10W
 616        Digitalmultimeter                        Fluke 177              88900339                 Fluke                 24 M          -            30.05.2020
 617        Power Splitter/Combiner                  ZFSC-2-2-S+            S F987001108             Mini Circuits         -             2
 618        Power Splitter/Combiner                  50PD-634               600994                   JFW Industries USA    -             2
 619        Power Splitter/Combiner                  50PD-634               600995                   JFW Industries, USA   -             3
 620        EMI Test Receiver                        ESU 26                 100362                   Rohde-Schwarz         12 M          -            30.05.2019
 621        Step Attenuator 0-139 dB                 RSP                    100017                   Rohde & Schwarz       pre-m         2
                                                     Generic Test Load
 625        Generic Test Load USB                                           -                        CETECOM               -             2
                                                     USB
 627        data logger                              OPUS 1                 201.0999.9302.6.4.1.43   G. Lufft GmbH         24 M          -            30.03.2019
 634        Spectrum Analyzer                        FSM (HF-Unit)          826188/010               Rohde & Schwarz       pre-m         2
                                                     HDMI cable with
 637        High Speed HDMI with Ethernet 1m                                -                        KogiLink              -             2
                                                     Ethernet 1m
                                                     HDMI cable with
 638        HDMI Kabel with Ethernet 1,5 m flach                            -                        Reichelt              -             2
                                                     Ethernet 1,5m
 640        HDMI cable 2m rund                       HDMI cable 2m rund     -                        Reichelt              -             2
                                                     Certified HDMI cable
 641        HDMI cable with Ethernet                                        -                        PureLink              -             2
                                                     with
 642        Wideband Radio Communication Tester      CMW 500                126089                   Rohde&Schwarz         24 M          -            24.05.2019
 644        Amplifierer                              ZX60-2534M+            SN865701299              Mini-Circuits         -             -
 670        Univ. Radio Communication Tester         CMU 200                106833                   Rohde & Schwarz       24 M          -            30.05.2020
 671        DC-power supply 0-5 A                    EA-3013S               -                        Elektro Automatik     pre-m         2
 678        Power Meter                              NRP                    101638                   Rohde&Schwarz         pre-m         -
 683        Spectrum Analyzer                        FSU 26                 200571                   Rohde & Schwarz       12 M          -            30.05.2019
                                                                                                     Narda Safety Test
 686        Field Analyzer                           EHP-200A               160WX30702                                     24 M          -            29.03.2019
                                                                                                     Solutions
 687        Signal Generator                         SMF 100A               102073                   Rohde&Schwarz         12 M          -            30.05.2019
 688        Pre Amp                                  JS-18004000-40-8P      1750117                  Miteq                 pre-m         -
 690        Spectrum Analyzer                        FSU                    100302/026               Rohde&Schwarz         24 M          -            16.05.2019
 691        OSP120 Base Unit                         OSP120                 106833                   Rohde & Schwarz       12 M          -            30.05.2019
 692        Bluetooth Tester                         CBT 32                 100236                   Rohde & Schwarz       36 M          -            29.05.2020
                                                     CTC-Radio Lab
 693        TS8997                                                          -                        Rohde&Schwarz         12 M          5            30.05.2019
                                                     1_TS8997
 697        Power Splitter                           ZN4PD-642W-S+          165001445                Mini-Circuits         -             2
 701        CMW500 wide. Radio Comm.                 CMW500                 158150                   Rohde & Schwarz       12 M          -            30.07.2019
                                                     MA 4010-KT080-         MA4170-KT100-XPET-
 703        INNCO Antennen Mast                                                                      INNCO                 pre-m         -
                                                     XPET-ZSS3              ZSS3


CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 16 of 17
 Ref.-No.




                                                                                                                   calibration
                                                                                                                   Interval of



                                                                                                                                     Remark
                           Equipment                     Type                 Serial-No.         Manufacturer                                    Cal
                                                                                                                                                 due

                                                                                             INNCO Systems
 704        INNCON Controller                   CO 3000-4port        CO3000/933/38410516/L                         pre-m         -
                                                                                             GmBh
 711        Harmonic Mixer 90 GHz - 140GHz      RPG FS-Z140          101004                  RPG                   36 M          -            22.02.2020
 712        Harmonic Mixer 75 GHz - 110GHz      FS-Z110              101468                  Rohde & Schwarz       36 M          -            22.02.2020
 713        Harmonic Mixer, 50 GHz - 75GHz      FS-Z75               101022                  Rohde & Schwarz       36 M          -            22.05.2020
 714        Signal Analyzer 67GHz               FSW67                104023                  Rohde & Schwarz       24 M          -            28.02.2020
                                                                                             RPG Radiometer
 715        Harmonic Mixer, 140 GHz - 220GHz    FS-Z220              101009                                        36 M          -            03.08.2020
                                                                                             Physics
                                                                                             RPG Radiometer
 716        Harmonic Mixer 220 GHz to 325 GHZ   FS-Z325              101005                                        36 M          -            13.02.2020
                                                                                             Physics
 747        Spectrum Analyzer                   FSU 26               200152                  Rohde & Schwarz       12 M          -            30.05.2019
 748        Pickett-Potter Horn Antenna         FH-PP 4060           010001                  Radiometer Physiscs   36 M          -
 749        Pickett-potter Horn Antenna         FH-PP 60-90          010003                  Radiometer Physics    -             -
 750        Pickett-Potter Horn Antenna         FH-PP 140-220        010011                  Radiometer Physics    -             -
                                                optoCAN-FD                                   mk-messtechnik
 751        Digital Optical System                                   17-010416                                     -             -
                                                Transceiver                                  GmbH
                                                optoCAN-FD                                   mk-messtechnik
 752        Digital Optical System                                   17-010083                                     -             -
                                                Transceiver                                  GmbH
                                                optoCAN-FD                                   mk-messtechnik
 753        Digital Optical System                                   17-010084                                     -             -
                                                Transceiver                                  GmbH
                                                optoCAN-FD                                   mk-messtechnik
 754        Digital Optical System                                   17-010415                                     -             -
                                                Transceiver                                  GmbH
                                                optoLAN-100-MAX                              mk-messtechnik
 755        Digital Optical System                                   17-010795                                     -             -
                                                Transceiver                                  GmbH
 758        Signal Generator                    SMU 200A             100754                  Rohde & Schwarz       24 M          -            11.10.2019
 780        Spectrum Analyzer                   FSH3                 101726                  Rohde & Schwarz       24 M          -            19.07.2019
                                                                                             Elektro-Automatik
 781        Power Supply                        PS 2042-10 B         2815450369                                    -             -
                                                                                             GmbH &Co.KG
                                                                                             lektro-Automatik
 782        Power Supply                        PS 2042-10 B         2815450348                                    -             -
                                                                                             GmbH &Co.KG
 783        Spectrum Analyzer                   FSU 26               100414                  Rohde & Schwarz       12 M          -            30.05.2019
 784        Power Supply                        NGSM 32/10           00196                   Rohde & Schwarz       12 M          -
                                                RF Step Attenuator
 785        RSP                                                      860712/012              Rohde & Schwarz       12 M          -
                                                0…139.9dB
 786        SAR Probe                           ES3DV3               3340                    Speag                 36 M          -            14.02.2021
 787        OSP                                 OSP B157WX           101264                  Rohde & Schwarz       12 M          -            30.05.2019
                                                                                             Seibersdorf
 788        Precision Omnidirectional Dipole    POD 618              6182558/Q                                     36 M          -            30.06.2021
                                                                                             Labaratories
                                                                                             Seibersdorf
 789        Precision Omnidirectional Dipole    POD 16               162496/Q                                      36 M          -            30.06.2021
                                                                                             Laboratories




CETECOM_TR18-1-0239001T01a


Test Report 18-1-0239001T01a, Page 17 of 17


8.1.3. Legend
 Note / remarks                     Calibrated during system calibration:
                          1a        System CTC-SAR-EMS (Ref.-No. 442)
                          1b        System-CTC-EMS-Conducted (Ref.-No. 335)
                          1c        System CTC-FAR-EMI-RSE (Ref.-No . 443)
                          1d        System CTC-SAR-EMI (Ref.-No . 441)
                          1e        System CTC-OATS (EMI radiated) (Ref.-No. 337)
                          1f        System CTC-CTIA-OTA (Ref.-No . 420)
                          1g        System CTC-FAR-EMS (Ref.-No . 444)
                          2         Calibration or equipment check immediately before measurement
                          3         Regulatory maintained equipment for functional check or support purpose
                          4         calibration of this equipment
                                    Ancillary equipment   without has no effect
                                                                  calibration   onmechanical
                                                                              e.g. measuring equipment
                                                                                             result    or monitoring equipment
                          5         Test System


Interval of calibration   12 M      12 month
                          24 M      24 month
                          36 M      36 month
                          24/12 M   Calibration every 24 months. between this every 12 months internal validation
                          36/12 M   Calibration every 36 months. between this every 12 months internal validation
                          Pre-m     Check before starting the measurement
                          -         Without calibration




9. Versions of test reports (change history)
       Version            Applied changes                                                                                        Date of release
         --               Inital release                                                                                          2018-12-28



                                    END OF TEST REPORT




CETECOM_TR18-1-0239001T01a



Document Created: 2019-01-18 11:25:06
Document Modified: 2019-01-18 11:25:06

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC