Test report DFS

FCC ID: YBN-AIVISBX0

Test Report

Download: PDF
FCCID_4248620

                                              TEST REPORT
                                            No.: 18-1-0221601T03a-C1

                                                            According to:

                                                        FCC Regulations
                                                          Part 15.205
                                                          Part 15.209
                                                          Part 15.407

                                                        ISED-Regulations
                                                         RSS-Gen, Issue 4
                                                         RSS-247, Issue 2

                                                                 for
                                Robert Bosch Car Multimedia GmbH

                                             AIVISBX0
                             Navigationsystem with WLAN and Bluetooth
                                                    FCC ID: YBN-AIVISBX0
                                                     ISED: 9595A-AIVISBX0




                                             Laboratory Accreditation and Listings



                                                        Industry Canada              Voluntary Controls for Electromagnetic
                                                                                                  Emissions
                                                       Reg. No.: 3462D-1
                                                       Reg. No.: 3462D-2
                                                                                           Reg. No.:4452, C-20009,
           Accredited EMC-Test Laboratory              Reg. No.: 3462D-3
                                                                                             T-20006, G-20013




                                                                                              MRA US-EU 0003

                                      accredited according to DIN EN ISO/IEC 17025

                                                      CETECOM GmbH
                              Laboratory Radio Communications & Electromagnetic Compatibility
                                          Im Teelbruch 116 • 45219 Essen • Germany
                                 Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                               Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                   E-mail: info@cetecom.com • Internet: www.cetecom.com


                                            Laboratory Accreditation and Listings




                                                                                                                       Page 1 of 25
The test results relate only to the individual items that have been tested. This report shall not be reproduced in parts without the
written approval of the testing laboratory                                         © Copyright: All rights reserved by CETECOM


Test Report 18-1-0221601T03a-C1, Page 2 of 25


Table of Contents
1. SUMMARY OF TEST RESULTS................................................................................................................... 3
  1.1. Tests measurement overview according to US CFR Title 47, Subpart 15C ................................................. 3
  1.2. Attestation:.................................................................................................................................................... 6
2. ADMINISTRATIVE DATA ............................................................................................................................ 7
  2.1. Identification of the testing laboratory .......................................................................................................... 7
  2.2. Test location ................................................................................................................................................. 7
  2.3. Organizational items ..................................................................................................................................... 7
  2.4. Applicant’s details ........................................................................................................................................ 7
  2.5. Manufacturer’s details .................................................................................................................................. 7
3. EQUIPMENT UNDER TEST (EUT) .............................................................................................................. 8
  3.1. Certification Data of Main EUT declared by Applicant ............................................................................... 8
  3.2. WLAN 5 GHz 802.11a/n Technical Data Of Main EUT as Declared by Applicant ................................... 9
  3.3. EUT: Type, S/N etc. and short descriptions used in this test report ........................................................... 10
  3.4. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions ............................................................. 10
  3.5. EUT set-ups ................................................................................................................................................ 10
  3.6. EUT operating modes ................................................................................................................................. 10
4. DESCRIPTION OF TEST SYSTEM SET-UP’S ......................................................................................... 11
5. U-NII DFS RULE REQUIREMENT ............................................................................................................ 12
6. MEASUREMENTS ........................................................................................................................................ 13
  6.1. Dynamic frequency selection (DFS) ........................................................................................................... 13
  6.2. Parameters of DFS test signals ................................................................................................................... 14
  6.3. Test results .................................................................................................................................................. 16
  6.4. Measurement uncertainties ......................................................................................................................... 20
7. ABBREVIATIONS USED IN THIS REPORT ............................................................................................ 21
8. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES .................... 21
9. INSTRUMENTS AND ANCILLARY ........................................................................................................... 22
  9.1. Test software and firmware of equipment .................................................................................................. 22
  9.2. Single instruments and test systems ............................................................................................................ 23
  9.3. Legend ........................................................................................................................................................ 25
10. VERSIONS OF TEST REPORTS (CHANGE HISTORY) ...................................................................... 25
END OF TEST REPORT ................................................................................................................................... 25


Table of annex                                                                                                                                        Total pages
Annex 1: Test result diagrams (separate document) CETECOM-TR18-1-0048201T01a-A1                                                                                    264
Annex 2: External photographs of EUT (separate document) CETECOM- TR18-1-0048201T02a-A2                                                                                8
Annex 3: Internal photographs of EUT (separate document supplied by customer)                                                                                         --
Annex 4: Test set-up photographs (separate document) CETECOM- TR18-1-0048201T02a -A4                                                                                   8




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 3 of 25



1. Summary of test results
The test results apply exclusively to the test samples as presented in this report. The CETECOM GmbH
does not assume responsibility for any conclusions and generalizations taken in conjunction with other
specimens or samples of the type of the item presented to tests. Also we refer on special conditions which
the applicant should fulfill according §2.927 to §2.948, special focus regarding modification of the
equipment and availability of sample equipment for market surveillance tests.

The presented Equipment Under Test (in this report, hereinafter referred as EUT) supports radiofrequency
technologies with WLAN technology and operating frequency range at 5.150 to 5.850 GHz according to IEE
802.11 a. The EUT integrates a WLAN transmitter. Other implemented wireless technologies were not considered
within this test report.

Following test cases have been performed to show compliance with valid Part 15.407/15.209 of the FCC CFR
Title 47 Rules, Edition 2017 and ISED RSS-247 Issue 2/RSS-Gen Issue 4 standards.


1.1. Tests measurement overview according to US CFR Title 47, Subpart 15C

                                                References and Limits                      EUT    EUT
  Test cases       Port                                                                    set-    op.    Result
                                FCC Standard       RSS Standard           Test limit
                                                                                            up    mode
                                                       TX-Mode
                  Antenna
 99% occupied                                      RSS-Gen, Issue 4       99% Power
                  terminal         2.1049(h)                                                2      1     Remark 1)
  bandwidth                                          Chapter 6.6          bandwidth
                (conducted)
                                    §15.303
                  Antenna              +
     26 dB                                         RSS-Gen, Issue 4      26 dB spectral
                  terminal         §15.407(a)                                               2      1     Remark 1)
   bandwidth                                         Chapter 6.6       density bandwidth
                (conducted)           (2)
                                      (5)
                  Antenna
                                 KDB789033 +      KDB789033 +
  Duty-Cycle      terminal                                             No Limit Criteria    2      1     Remark 1)
                                ANSI C63.10:2013 ANSI C63.10:2013
                (conducted)
  Transmitter     Antenna                                              Operation within
                                   § 2.1055 +      RSS-Gen, Issue 4:
   frequency      terminal                                               designated         2      1     Remark 1)
                                   §15.407(g)        Chapter 6.11
    stability   (conducted)                                            operational band




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 4 of 25

                                                                      Power Limits (if
                                                   RSS-247, Issue 2
                                   §15.407(a)                         Antenna Gain < 6
                                                      Chapter
                                                                           dBi)
                                      (1)(iv)
                    Antenna       5.15-5.25 GHz        6.2.1.1             250 mW
  Maximum                         Client devices
                    terminal                                                                 2    1     Remark 1)
 output power
                  (conducted)           (2)
                                                                       lesser of 250mW
                                5.25-5.35 GHz &        6.2.2.1
                                                                      or 11dBm+10logB
                                 5.47-5.725 GHz
                                        (3)            6.2.3.1
                                                                             1W
                                 5.725-5.85 GHz        6.2.4.1
                                                                       Power Spectral
                                                   RSS-247, Issue 2   Density Limits (if
                                   §15.407(a)
                                                      Chapter         Antenna Gain < 6
                                                                            dBi)
                                      (1)(iv)
  Peak Power        Antenna       5.15-5.25 GHz        6.2.1.1           11dBm/MHz
   Spectral         terminal      Client devices                                             2    1     Remark 1)
    density       (conducted)           (2)
                                5.25-5.35 GHz &        6.2.2.1           11dBm/MHz
                                 5.47-5.725 GHz
                                      (3)              6.2.3.1
                                                                       30dBm/500kHz
                                5.725-5.85 GHz         6.2.4.1
                                                                      e.i.r.p. Limits (if
                                                   RSS-247, Issue 2
                                   §15.407(a)                         Antenna Gain < 6
                                                      Chapter
                                                                             dBi)
                    Antenna          (1)(iv)
                    terminal     5.15-5.25 GHz         6.2.1.1         250 mW + 6 dBi
                  (conducted)    Client devices
   Maximum
                                                                       lesser of 250mW       2    1     Remark 1)
 e.i.r.p. power                        (2)
                      +                                               or 11dBm+10logB
                                5.25-5.35 GHz &        6.2.2.1
                   Antenna                                                     +
                                 5.47-5.725 GHz
                    Gain                                                     6 dBi
                                      (3)              6.2.3.1
                                                                         1 W + 6 dBi
                                5.725-5.85 GHz         6.2.4.1
                                                                            < 6dBi or
                                                                           if Antenna
                                                                       directional Gain >
                                                   RSS-247, Issue 2    6dBi reduction of
                    Antenna                         chapter 6.2.1.1      Max. power &
 Antenna gain                      §15.407(a)                                                           Measured
                    terminal                           6.2.2.1           power spectral      --   --
 information                        (1)(2)(3)                                                          Antenna Gain.
                  (conducted)                          6.2.3.1           density by the
                                                       6.2.4.1         amount in dB that
                                                                      the directional gain
                                                                         of the antenna
                                                                         exceeds 6 dBi




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 5 of 25

                                                                          5150-5250 MHz |
                                                                          5250-5350 MHz
                                                     RSS-Gen., Issue 4    5470-5725 MHz
                                                             +              all emissions
  General field                                      RSS-247, Issue 2     outside operating
                                   §15.407(b)
    strength                                              Chapter          band shall not
                                (1)(2)(3)(4)(5)(6)
   emissions                                          6.2.1.2 , 6.2.2.2      exceed -27
                                      (7)(8)
     within                                               6.2.3.2,        dBm/MHz e.i.r.p.
                  Enclosure +
   restricted                                                +
                     Inter-
     bands                                                6.2.4.2         5725-5850 MHz
                  connecting                                                                    1    1     Remark 1)
                                                                          Spectrum Mask
                     cables
       +                                                                    acc. to (4)(i)
                   (radiated)
                                                     RSS-Gen., Issue 4
  Band-Edge                                                  +
                                                                           Restricted band
  compliance                                         RSS-247, Issue 2
                                    §15.205                                     limits
    radiated                                              Chapter
                                       +                                          +
                                                      6.2.1.2 , 6.2.2.2
                                    §15.209                                 General field
                                                          6.2.3.2,
                                                                           strength limits
                                                             +
                                                          6.2.4.2
    Transmit
 power control
                                                     RSS-Gen., Issue 4     Requirements:
        +           Antenna
                                    §15.407                +                  Masters
    Dynamic         terminal                                                                    2    3         Pass
                                    (h1)(h2)         RSS-247, Issue 2      Active clients
   frequency      (conducted)
                                                       Chapter 6.3         Passive clients
    selection
     (DFS)
                                                                          No transmissions
                                                                           in case of either
                                                                              absence of
                                                                            information to                  Not tested
Discontinuous
                                   §15.407(c)        RSS-247, Issue 2         transmit or
 transmissions
                FIRMWARE               +               Chapter 6.4        operational failure   --   --     Applicants
       +
                                   §15.407(i)           a+b+c                      +                       declaration of
Device security                                                                                           implementation
                                                                             Protection of
                                                                               firmware
                                                                           by unauthorized
                                                                                 parties
                  AC-Power
   AC-Power
                    lines                            RSS-Gen, Issue 4:
     Lines                                                                 AC Power line
                      or           §15.207(a)          Chapter 8.8                              --   --   Not applicable
   Conducted                                                              conducted limits
                   Battery                               Table 3
   Emissions
                   Charger
Remark 1) Please refer to separate FCC RF Test Report CETECOM_18-1-0048201T01a




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 6 of 25


                 RF-Exposure Evaluation (separation distance user to RF-radiating element greater 20cm)

                                                                  References & Limits                      EUT          EUT
    Test cases                    Port                 FCC                                                 set-          Op               Result
                                                                    RSS Section         Test Limit          up          mode
                                                     Standard



                                                                                    SAR-Limits
                                                                                                              1            1
                                                                                   FCC: 1.1310(b)
       Radio                  Cabinet
                                 +                                                                                                   See separate test
    frequency                                        §1.1310(b)                                                                           reports
                               Inter-                                 RSS-102
     radiation                                        §2.1091                         RF-Field                                       CETECOM_TR
                             connecting                                Issue 5                                                             18-1-
     exposure                                         §2.1093                     Strength Limits:
  requirements                 cables                                              FCC: “general
                                                                                                                                      0048201T05a
                                (radiated)
                                                                                     population/
                                                                                                              1            1
                                                                                    uncontrolled”
                                                                                    environment
                                                                                       Table 1
                                                                                   ISED: Table 4


1.2. Attestation:
I declare that all measurements were performed by me or under my supervision and that all measurements have been performed and are
correct to my best knowledge and belief to Innovation , Science and Economic Development (ISED) Canada standards. All requirements
as shown in above table are met in accordance with enumerated standards.

The current version of the Test Report CETECOM_TR18-1-0221601T03a-C1 replaces the Test Report
CETECOM_TR18-1-0221601T03a dated 2018-12-10. The replaced test report is herewith invalid.



                                                                                                                          Ninovic
                                                                                                                          Perez
                                                                                                                          2018.12.14
                                                                                                                          09:20:55 +
                                                                                                                          01'00'
..................................................                                               ....................................................
Dipl.-Ing. Niels Jeß                                                                                                  Dipl.-Ing N. Perez
Responsible for test section                                                                               Responsible for test report




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 7 of 25


2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                         CETECOM GmbH
Address:                                                              Im Teelbruch 116
                                                                      45219 Essen - Kettwig
                                                                      Germany
Responsible for testing laboratory:                                   Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                         see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Responsible for test report and                                       Dipl.-Ing N. Perez
Project leader:                                                       Dipl.-Ing N. Perez
Receipt of EUT:                                                       2018-08-20
Date(s) of test:                                                      2018-08-22 - 2018-12-03
Date of report:                                                       2018-12-14
       -----------------------------------------------------------------------------------------------------------------------------------------------------

Version of template:             13.02
2.4. Applicant’s details

Applicant’s name:                                                     Robert Bosch Car Multimedia GmbH
Address:                                                              Robert-Bosch-Straße 200
                                                                      31139 Hildesheim
                                                                      Germany
Contact :                                                             Mr. Salvatore Miraglia

2.5. Manufacturer’s details

Manufacturer’s name:                                                  see applicant's details
Address:                                                              see applicant's details




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 8 of 25


3. Equipment under test (EUT)
3.1. Certification Data of Main EUT declared by Applicant
Model Nr.                         AIVISBX0
Type                              Navigationsystem with WLAN and Bluetooth
FCC ID                            AIVISBX0
IC/ ISED                          YBN-AIVISBX0
                                   5150 MHz (Channel 36) to 5250 MHz (Channel 48) for 20MHz BW
Frequency range                    5250 MHz (Channel 52) to 5350 MHZ (Channel 64) for 40MHz BW
(US/Canada -bands)                 5470 MHz (Channel 100) to 5725 MHZ (Channel 140) for 40MHz BW
                                   5725 MHz (Channel 149) to 5850 MHZ (Channel 165) for 40MHz BW
Type of modulation                See chapter 3.2
                                   Integrated
Antenna Type                       External, no RF- connector
                                   External, separate RF-connector
Antenna Model                     PCB Antenna
Antenna Gain                      5.1 dBi


                                   802.11 a/n/ac
                                   802.11 b/g/n (not tested within this report)
Installed options
                                   Bluetooth LE (not tested within this report)
                                   Bluetooth EDR (not tested within this report)
                                   Internal battery Li-Io, range 3.5V to 4.1V
Power supply                       over AC/DC adapter: 110V/60 Hz
                                   Nominal Test Voltage : 13.5 V DC with external power supply
 Special EMI components           --
 EUT sample type                   Production                       Pre-Production    Engineering
 FCC label attached                yes                              no
Remark:




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 9 of 25

3.2. WLAN 5 GHz 802.11a/n Technical Data Of Main EUT as Declared by Applicant
Firmware Version                --
                                                            Ch 36 | 40 | 44| 48    Bandwidth 20 MHz
                                U-NII 1: 5150-5250 MHz      Ch. 38 | 46            Bandwidth 40 MHz
                                                            Ch. 42                 Bandwidth 80 MHz
                                                            Ch 52 | 56 | 60| 64    Bandwidth 20 MHz
                                U-NII2A: 5250-5350 MHz      Ch. 54 | 62            Bandwidth 40 MHz
                                                            Ch. 58                 Bandwidth 80 MHz
                                                            Ch 100 | 104 | 108
                                                            Ch 112 | 116 | 120
Frequency | Channel | B.W.                                                          Bandwidth 20 MHz
                                                            Ch 124 | 128 | 132
    (USA bands only)**
                                U-NII 2C: 5470-5725 MHz     Ch 136 | 140
                                                            Ch. 102 | 110 | 118
                                                                                    Bandwidth 40 MHz
                                                            Ch 126 | 134
                                                            Ch 106 | 122           Bandwidth 80 MHz
                                                            Ch 149 | 153 | 157
                                                                                    Bandwidth 20 MHz
                                                            Ch 161 | 165
                                U-NII 3: 5725 -5850 MHz
                                                            Ch 151 | 159           Bandwidth 40 MHz
                                                            Ch 155                 Bandwidth 80 MHz
                                 BPSK | 6 Mbps / 9 Mbps
802.11a – Mode OFDM              QPSK | 12 Mbps / 18 Mbps
Modulation | Data Rates          16-QAM | 24 Mbps / 36 Mbps
                                 64-QAM | 48 Mbps / 54 Mbps
802.11n – Mode OFDM              HT20 (MCS0 – MCS7) | 7.2/14.4/21.7/28.9/43.3/57.8/65/72.2 Mbps
Modulation | Data Rates          HT40 (MCS0 – MCS7) | 15/30/45/60/90/120/135/150 Mbps
                                 HT20 (MCS0 – MCS9) | 7.2/14.4/21.7/28.9/43.3/57.8/65/72.2 Mbps
802.11ac – Mode OFDM
                                 HT40 (MCS0 – MCS9) | 15/30/45/60/90/120/135/150 Mbps
Modulation | Data Rates
                                 HT80 (MCS0 – MCS9) | 7.2/14.4/21.7/28.9/43.3/57.8/65/72.2 Mbps
Power Supply                     Nominal Test Voltage : 13.5V DC with external power supply
Special EMI Components          --
EUT sample type                  Production      Pre-Production        Engineering
FCC label attached               yes             no
                                                     MASTER
   DFS equipment type                                SLAVE with DFS-capability
                                                     SLAVE without DFS-capability
                                                     IEEE802.11n (2012)
  Description of Medium
                                                     IEEE 802.11ac (2014)
  access protocol
                                                     applicant specific




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 10 of 25

3.3. EUT: Type, S/N etc. and short descriptions used in this test report

 Short
                                                                  S/N              HW                   SW
 descrip-            EUT                     Type
                                                             serial number       hardware          software status
 tion*)
                                                                                  status
                                      Navigationsystem
 EUT A            AIVISBX0            with WLAN and            0005009           C-Sample               1003
                                         Bluetooth
*) EUT short description is used to simplify the identification of the EUT in this test report.


3.4. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions
    AE
                                                                      S/N              HW              SW
   short      Auxiliary Equipment              Type
                                                                 serial number    hardware status software status
 descrip-
  tion *)
                                                                S7291GC0003
  AE 1        USB-cable (Dongle)              0,38m                                 Version-D1              --
                                                                     79

  AE 2        Power Supply Cable                 --                    --                 --                --

  AE 3             Notebook               Lenovo X200S            LVZT1DG                 --                --

                                         CISCO AIR-
  AE 4              Router                                      FJC2005F37L               --                --
                                        CAP2702E-A-K9
*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.


3.5. EUT set-ups

 EUT set-
                 Combination of EUT and AE                                     Description
 up no.*)

               EUT A + AE 1 + AE 2 + + AE 3
   set. 1                                                           Conducted measurement set-up
                         + AE 4
*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.



3.6. EUT operating modes

    EUT
                  Description of
  operating                                                      Additional information
                 operating modes
    mode
   no.*1)
                                    EUT was connected to a router. Traffic was generated via software tool
    op. 1         Normal mode
                                    iperf.
*1) EUT operating mode no. is used to simplify the test report.
*2) Please refer to document “Instructions_RadioTypeApproval_9_6_2017” dated 2017-06-09 for additional
information regarding operating mode setup and output power levels.




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 11 of 25


4. Description of test system set-up’s
Three theoretical set-ups for coupling the signals into the EUT are shown below, depending from the intended
use of the equipment.

                                     Figure                                             Set-up Designation



                                                                                             Set-up A:

                                                                                      EUT is Master with DFS
                                                                                     capability. The test signals
                                                                                    are injected into the R-LAN
                                                                                            EUT during a
                                                                                        communication link
                                                                                      connection to a SLAVE
                                                                                               device.




                                                                                             Set-up B:

                                                                                   EUT is slave with or without
                                                                                      DFS capability. The test
                                                                                    signals are injected into the
                                                                                     MASTER R-LAN device
                                                                                   during a communication link
                                                                                     connection to the SLAVE
                                                                                               device.




                                                                                             Set-up C:

                                                                                      EUT is slave with DFS
                                                                                    capability. The test signals
                                                                                     are injected into the Slave
                                                                                   during a communication link
                                                                                   connection to a RLAN device
                                                                                       working as MASTER.




The Set-up is realized by the OSP-Unit from R&S Testsystem TS8997, RF-Output Port 1 is connected to EUT’s
DFS Measurement port. Any path losses are calibrated out, so the test signal is on the threshold level as stated by
the standard in Table D.2.

The companion device is a Cisco Aironet 2700 Series 802.11ac Dual Band Access Point, Model AIR-
CAP2702E-A-K9 (S/N FJC2005F37L). This is a DFS Master device with FCC-ID LDK102091/ ISED 2461B-
102091.

CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 12 of 25


5. U-NII DFS Rule Requirement
Applicability of DFS requirements prior to use a channel
 Requirement                                     Operation Mode
                                                 Master                  Client without       Client with
                                                                         radar detection      radar detection
 Non-Occupancy Period                                     X                      X                   X
 DFS Detection Threshold                                  X                 Not required             X
 Channel Availability Check Time                          X                 Not required        Not required
 Uniform Spreading                                        X                 Not required        Not required
 U-NII Detection Bandwidth                                X                 Not required             X


Applicability of DFS requirements during normal operation
 Requirement                                  Operation Mode
                                              Master                     Client without       Client with
                                                                         radar detection      radar detection
 DFS Detection Threshold                                  X                 Not required             X
 Channel Closing Transmission Time                        X                      X                   X
 Channel Move Time                                        X                      X                   X
 U-NII Detecion Bandwidth                                 X                 Not required             X


 Additional requirements for            Master Device or Client with            Client without Radar Detection
 devices with multiple bandwidth Radar Detection
 modes
 U-NII Detection Bandwidth and          All BW modes must be tested             Not required
 Statistical Performance Check
 Channel Move Time and Channel          Test using widest BW available          Test using the widest BW mode
 Closing Transmission Time                                                      available for the link
 All other tests                        Any single BW mode                      Not required
 Note: Frequencies selected for statistical performance check should include several frequencies within the
           radar detection bandwidth and frequencies near the edge of the radar detection bandwidth.
           For 802.11 devices it is suggested to select frequencies in each of the bonded 20MHz channel and
           the channel center frequencies.




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 13 of 25


6. Measurements
6.1. Dynamic frequency selection (DFS)
6.1.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
test location   CETECOM Essen (Chapter. 2.2.1)             443 System CTC-FAR-EMI-                Please see Chapter. 2.2.3
 test site      441 EMI SAR  487 SAR NSA                  347 Radio.lab.  TS 8997                               
 receiver       377 ESCS30       001 ESS                  489 ESU 40                                            
                584 FSU
 spectr. analys.                  120 FSEM                 264 FSEK        489 ESU 40                            
 antenna        574 BTA-L        133 EMCO3115             302 BBHA9170  289 CBL 6141            030 HFH-Z2  477 GPS
 signaling      392 MT8820A  436 CMU                      547 CMU
 otherwise      266 NRV-Z31  600 NRVD                     110 USB LWL  482 Filter Matrix        378 RadiSense  693 TS8997
 DC power       671 EA-3013S  463 HP3245A                 459 EA 2032-50  268 EA- 3050          494 AG6632A  498 NGPE 40
                                       6 dB                      Power
                331 HC 4055      248                      529             - cable OTA20
otherwise                              Attenuator                divider
                530 10dB Attenuator                        K 4 Cable kit
Supply voltage  13.5V DC                                   060 110 V 60 Hz via PAS 5000

6.1.2. Reference
  FCC                                          Part 15 Subpart C, §15.407(a)(1)(2)(3)(4)

                                               RSS-247, Issue 2
  ISED
                                               RSS-Gen, Issue 4

  ANSI                                         C63.10-2013
                                               UNII: KDB 789033 D02 v02r01             Guidelines for Compliance Testing
  KDB Guidance no.                             UNII: KDB 905462 D03 v01r02             Client Without DFS New Rules
                                               UNII: KDB 905462 D04 v01                Operational Modes for DFS Testing New Rules


6.1.3. EUT settings:
The EUT was connected to a router. With help of iperf a continuous transmission was set.

6.1.4. Test condition and measurement test set-up
Signal ink to test system (if used):          air link      cable connection        none
EUT-grounding                                 none          with power supply  additional connection
Equipment set up                              table top 1.5m height                  floor standing
Climatic conditions                          Temperature: (22±3°C)                   Rel. humidity: (40±20)%
General measurement procedures               Please see chapter “Test system set-up for conducted RF-measurement at antenna Port” (W1
                                             Set-up)



6.1.5. Test Results summary:
    Clause                             Test Parameter                                       Remarks                        Pass/Fail

    15.407         DFS Detection Threshold                                     Not applicable                       N/A

    15.407         Channel Availability Check Time                             Not applicable                       N/A

    15.407         Channel Move Time                                           Applicable                           Pass

    15.407         Channel Closing Transmission Time                           Applicable                           Pass

    15.407         Non-Occupancy Period                                        Applicable                           Pass

    15.407         Uniform Spreading                                           Not applicable                       N/A

    15.407         U-NII Detection Bandwidth                                   Not applicable                       N/A
Remark: Widest supported BW of EUT is 80MHz. According KDB 905462 D03 only testing in 40MHz is needed.




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 14 of 25

6.2. Parameters of DFS test signals
6.2.1. DFS Detection Threshold for Master Devices as well as Client Devices With Radar Detection

 Maximum Transmit Power EIRP                                 Value (see note)
 ≥200mW                                                      -64 dBm
 < 200mW and power spectral density < 10dBm/MHz -62 dBm
 <200mW and that do not meet the power spectral              -64 dBm
 density < 10dBm/MHz
 Note 1: This is the level at the input if the receiver assuming a 0 dBi receive antenna.
 Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of the test
 transmission waveforms to account for variations in measurement equipment. This will ensure that the test
 signal is at or above the detection threshold level to trigger a DFS response.
 Note 3: EIRP is based on the highest antenna gain. For MIMO devices refer to KDB Publication 662911 D01.



6.2.2. DFS Response Requirement Values

 Parameter                                               Value
 Non-occupancy period                                    Minimum 30 minutes
 Channel Availability Check Time                         60 seconds
 Channel Move Time                                       10 seconds (see Note 1)
 Channel Closing Transmission Time                       200 milliseconds + an aggregate of 60 milliseconds
                                                         over remaining 10 seconds period
                                                         (See Notes 1 and 2)
 U-NII Detection Bandwidth                               Minimum 100% of the U-NII 99% transmission
                                                         power bandwidth (See Note 3)
 Note 1: Channel Move Time and the Channel Closing Transmission Time should be performed with Radar
         Type 0. The measurement timing begins at the end of the Radar Type 0 burst.
 Note 2: The Channel Closing Time plus any additional intermittent control signals required to facilitate a
         Channel move (an aggregate of 60 milliseconds) during the remainder of the 10 second period.
         The aggregate duration of the control signals will not count quiet periods in between transmissions.
 Note 3: During the U-NII Detection Bandwidth detection test, radar type 0 should be used. For each
         frequency step the minimum percentage of detection is 90 percent. Measurements are performed
         with no data traffic.




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 15 of 25

6.2.3. Radar Test Waveforms

Short Pulse Radar Test Waveforms
 Radar Type      Pulse Width     PRI (µsec)           Number of Pulses      Minimum          Minimum
                 (µsec)                                                     Percentage of    Number of
                                                                            Successful       Trials
                                                                            Detecion
 0                 1                1428              18                    See Note 1       See Note 1
 1                 1                Test A: 15                              60%              30
                                    unique PRI
                                    values
                                    randomly
                                    selected from
                                    the list of 23
                                    PRI values in
                                    Table 5a
                                    Test B: 15
                                    unique PRI
                                    values
                                    randomly
                                    selected within
                                    the range of
                                    518-3066 µsec,
                                    with a
                                    minimum
                                    increment of 1
                                    µsec,
                                    excluding PRI
                                    values selected
                                    in Test A
 2                1-5               150-230           23-29               60%                30
 3                6-10              200-500           16-18               60%                30
 4                11-20             200-500           12-16               60%                30
 Aggregate (Radar Types 1-4)                                              80%                120
 Note 1: Short Pulse Radar Type 0 should be used for the detection bandwidth test, channel move time, and
         channel closing time tests.

A minimum of 30 unique waveforms are required for each of the Short Pulse Radar Types 2 through 4.

Long Pulse Radar Test Waveforms
 Radar       Pulse       Chirp            PRI          Number of     Number pf      Minimum      Minimum
 Type        Width       Width            (µsec)       Pulses per    Bursts         Percentage   Number of
             (µsec)      (MHz)                         Burst                        of           Trails
                                                                                    Successful
                                                                                    Detection
 5            50-100        5-20          1000 –       1-3           8-20           80%          30
                                          2000

The parameters for this waveform are randomly chosen. Thirty unique waveforms are required for the Long
Pulse Radar Type waveforms. If more than 30 waveforms are used for the Long Pulse Type waveforms, the each
additional waveform must also be unique and not repeated from the previous waveforms.

Frequency Hopping Radar Test Waveform
 Radar      Pulse       Chirp       PRI                Number of     Number pf      Minimum      Minimum
 Type       Width       Width       (µsec)             Pulses per    Bursts         Percentage   Number of
            (µsec)      (MHz)                          Burst                        of           Trails
                                                                                    Successful
                                                                                    Detection
 6            1             333           9            0.333         300            70%          30


CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 16 of 25

6.3. Test results

DFS In-Service Monitoring (5270 MHz; 11,000 dBm; 40 MHz)

Test according to FCC title 47 part 15 §15.407(h), KDB 905462 D02 U-NII DFS Compliance Procedures
New Rules v02


Measurement uncertainty calculated in accordance with ETSI TR 100 028-1.
Expanded uncertainty (K=2) for Channel Closing Transmission Time in the first 200 ms: <10.208%
Expanded Uncertainty (K=2) for Channel Closing Transmission Time for the remaining channel move time
period:<2.632%
Expanded Uncertainty (K=2) for Channel Move Time:<0.1%


Measurement Summary
     DUT Frequency        Radar Type           Type of Measurement value                 Overall
         (MHz)               No.                                                          Result
          5270.000000               0   First of all Transmitt Test                     ---
          5270.000000               0   Channel Move Time                               PASS
          5270.000000               0   Channel Closing Transmission Time               PASS
          5270.000000               0   Non-occupancy period                            PASS

(continuation of the "Measurement Summary" table from column 4 ...)

     DUT Frequency              Overall Comment
         (MHz)
          5270.000000    not performed / not finished
          5270.000000
          5270.000000
          5270.000000



Channel Move Time Detailed Results
     DUT Frequency        Radar Type     CMT Tx      CMT Limit       CMT Result
         (MHz)               No.          Time         (s)
                                           (s)
          5270.000000               0       2.263         10.000    PASS

(continuation of the "Channel Move Time Detailed Results" table from column 5 ...)

     DUT Frequency                  CMT Comment
         (MHz)
                         Tx Time value is last trailing edge
          5270.000000
                         found within sweep. See Note 1.



Channel Closing Transmission Time Detailed Results
     DUT Frequency        Radar Type             CCTT Type of Value                 CCTT No. of      CCTT Tx
         (MHz)               No.                                                    Pulses found      Time
                                                                                                      (ms)
          5270.000000               0   first 200 ms                              177                   6.936
          5270.000000               0   remaining 10.0 second(s) period           121                  18.388

(continuation of the "Channel Closing Transmission Time Detailed Results" table from column 5 ...)

     DUT Frequency         CCTT Tx       CCTT Result           CCTT Comment
         (MHz)            Time Limit
                             (ms)
          5270.000000         200.000   PASS              See Note 1.
          5270.000000          60.000   PASS              See Note 1.




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 17 of 25



Non-occupancy period Detailed Results
     DUT Frequency         Radar Type      NOP No. of Pulses        NOP No. of     NOP Tx     NOP Tx
         (MHz)                No.               found               Pulses Limit    Time     Time Limit
                                                                                     (s)        (s)
            5270.000000               0    0                    0                    0.000        0.000

(continuation of the "Non-occupancy period Detailed Results" table from column 6 ...)

     DUT Frequency         NOP Result
         (MHz)
          5270.000000     PASS



Transmitting Test Detailed Results
     DUT Frequency          Tx-Test            Tx-Test Comment
         (MHz)              Result
          5270.000000     ---           not performed / not finished




Additional Information
    Note                                                Description

              Because of the radar pulse event at the beginning,
  Note 1:     the investigation of the trace begins with an offset of 26.7 ms
              conforming to the end of the Radar burst.


              Channel move time (CMT) / channel closing transmission time (CCTT) measurement
  Note 2:
              was made with hi resolution video sweep using OSP DAQ channel


              Because of the substantially higher sampling rate of the video signal
  Note 3:     the results for CCTT and CMT are more accurate than in the graphics visible.
              Reached timing accuracy of the video trace: approx 4 µs


              The Non-Occupancy Period trace starts at the end of the Channel move time trace
  Note 4:     (20.000 secs.)
              Labeling of the x-axis (time) is relative to its beginning (0 secs.)




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 18 of 25


Radar level verification
                                        Description                               Value         Unit
                                                                                  12.59    mW
  Configured DUT EIRP:
                                                                                  10.00    dBm/MHz
  Configured DUT PSD:
  Requirement of the Detection threshold value
                                                                                  -64      dBm
  for this given values acc. to FCC clause 5.2 / Table 3

  Vector Generator level setting                                                  -23.19   dBm

  Configured overall pathlost from Vector Generator RF out to
                                                                                  57.99    dB
  DUT connector of 'DUT to OSP'-cable
  Given additional level added to the amplitude of
  the waveform to account for variations in measurement                           1.00     dB
  equipment acc. to FCC clause 5.2 / Table 3 / Note 2
  This results in the following radar signal
                                                                                  -81.18   dBm
  level at the DUT



                        25
                        20
         Level in dBm




                        10

                         0

                        -10

                        -20


                              0    2         4        6        8        10       12        14          16   18   20
                                                                     Time in s

                          In-Service Monitoring Channel Move Time
                          Threshold
                          Start of Radar
                          Trigger at end of Radar
                          First 200ms of Channel Closing Tx Time
                          10sec Channel Move Time Limit
                          Last measured edge of Channel Closing Tx Time



                        25
                        20

                        10
         Level in dBm




                         0

                        -10

                        -20


                              0             50                100                150               200           250
                                                                    Time in ms

                          In-Service Monitoring Channel Move Time first 200ms
                          Threshold
                          Start of Radar
                          Trigger at end of Radar
                          First 200ms of Channel Closing Tx Time




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 19 of 25



                       25
                       20


                       10
        Level in dBm




                        0


                       -10


                       -20


                             0                    500                      1000                1500   1860
                                                                       Time in s

                         In-Service Monitoring Non-occupancy period                Threshold


In-Service Monitoring Channel Move Time

Channel Move Time; Channel Closing Transmission Time
         Setting         Instrument     Target Value
                            Value
  Center Frequency     5.27000 GHz     5.27000 GHz
  Span                 ZeroSpan        ZeroSpan
  RBW                  3.000 MHz       >= 3.000 MHz
  VBW                  3.000 MHz       >= 3.000 MHz
  SweepPoints          30001           ~ 30001
  Sweeptime            20.000 s        20.000 s
  Reference Level      -30.000 dBm     -30.000 dBm
  Attenuation          5.000 dB        AUTO
  Detector             MaxPeak         MaxPeak
  SweepCount           1               1
  Filter               3 dB            3 dB
  Trace Mode           Clear Write     Clear Write
  Sweeptype            Sweep           AUTO
  Preamp               off             off
  Trigger              External        External
  Trigger Offset       0.000 ms        0.000 ms

Non-occupancy period
        Setting                      Instrument         Target Value
                                        Value
  Center Frequency                 5.27000 GHz      5.27000 GHz
  Span                             ZeroSpan         ZeroSpan
  RBW                              3.000 MHz        >= 3.000 MHz
  VBW                              3.000 MHz        >= 3.000 MHz
  SweepPoints                      30001            ~ 30001
  Sweeptime                        1.860 ks         1.860 ks
  Reference Level                  -30.000 dBm      -30.000 dBm
  Attenuation                      5.000 dB         AUTO
  Detector                         MaxPeak          MaxPeak
  SweepCount                       1                1
  Filter                           3 dB             3 dB
  Trace Mode                       Clear Write      Clear Write
  Sweeptype                        Sweep            AUTO
  Preamp                           off              off




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 20 of 25

6.4. Measurement uncertainties

The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate
coverage factor k, such that a confidence level of approximately 95% is achieved.
For uncertainty determination, each component used in the concrete measurement set-up was taken in account and
it’s contribution to the overall uncertainty according it’s statistical distribution calculated.

Following table shows expectable uncertainties for each measurement type performed.

                                                                       Calculated uncertainty based on a
     RF-Measurement             Reference        Frequency range                                                 Remarks
                                                                           confidence level of 95%
 Conducted emissions                     9 kHz - 150 kHz           4.0 dB
                            CISPR 16-2-1                                                                             -
 (U CISPR)                               150 kHz - 30 MHz          3.6 dB
 Radiated emissions                      30 MHz - 1 GHz            4.2 dB
                            CISPR 16-2-3                                                                          E-Field
 Enclosure                               1 GHz - 18 GHz            5.1 dB
 Disturbance power          CISPR 16-2-2 30 MHz - 300 MHz          -                                                 -
                                                                                                                Substitution
 Power Output radiated              -       30 MHz - 4 GHz         3.17 dB
                                                                                                                method
                                                                   Cel- Cel-
                                            Set-up No.                          BT1 W1          W2         --
                                                                    C1     C2
 Power Output conducted             -       9 kHz - 12.75 GHz      N/A 0.60 0.7 0.25           N/A         --        -
                                            12.75 - 26.5GHz        N/A 0.82      --   N/A      N/A         --
 Conducted emissions                -       9 kHz - 2.8 GHz        0.70 N/A 0.70 N/A           0.69        --    N/A - not
 on RF-port                                 2.8 GHz - 12.75GHz     1.48 N/A 1.51 N/A           1.43        --    applicable
                                            12.75 GHz - 18GHz      1.81 N/A 1.83 N/A           1.77        --
                                            18 GHz - 26.5GHz       1.83 N/A 1.85 N/A           1.79        --
                                                                   0.1272 ppm (Delta Marker)                    Frequency
 Occupied bandwidth                 -       9 kHz - 4 GHz                                                       error
                                                                   1.0 dB                                       Power
                                    -                              0.1272 ppm (Delta Marker)                    Frequency
 Emission bandwidth                         9 kHz - 4 GHz                                                       error
                                    -                              See above: 0.70 dB                           Power
 Frequency stability                -       9 kHz - 20 GHz         0.0636 ppm                                         -
                                            150 kHz - 30 MHz       5.0 dB                                       Magnetic
 Radiated emissions                         30 MHz - 1 GHz         4.2 dB                                       field
                                    -
 Enclosure                                  1 GHz - 20 GHz         3.17 dB                                      E-field
                                                                                                                Substitution
Table: measurement uncertainties, valid for conducted/radiated measurements




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 21 of 25


7. Abbreviations used in this report
 The abbreviations
 ANSI                    American National Standards Institute
 AV . AVG. CAV           Average detector
 EIRP                    Equivalent isotropically radiated power. determined within a separate measurement
 EGPRS                   Enhanced General Packet Radio Service
 EUT                     Equipment Under Test
 FCC                     Federal Communications Commission. USA
 IC                      Industry Canada
 n.a.                    not applicable
 Op-Mode                 Operating mode of the equipment
 PK                      Peak
 RBW                     resolution bandwidth
 RF                      Radio frequency
 RSS                     Radio Standards Specification. Documents from Industry Canada
 Rx                      Receiver
 TCH                     Traffic channel
 Tx                      Transmitter
 QP                      Quasi peak detector
 VBW                     Video bandwidth
 ERP                     Effective radiated power




8. Accreditation details of CETECOM’s laboratories and test sites

 Ref.-   Accreditation                  Valid for laboratory area or test site
 No.      Certificate                                                                               Accreditation Body
 -          D-PL-                                                                             DAkkS. Deutsche
                         All laboratories and test sites of CETECOM GmbH. Essen
         12047-01-01                                                                          Akkreditierungsstelle GmbH
 337                 Radiated Measurements 30 MHz to 1 GHz. 3 m / 10 m (OATS)
                                                                                              FCC. Federal Communications
 487                 Radiated Measurements 30 MHz to 1 GHz. 3 m (SAR)
      (MRA US-EU                                                                              Commission
 558                 Radiated Measurements above 1 GHz. 3 m (FAR)
          0003)                                                                               Laboratory Division. USA
 348                 Mains Ports Conducted Interference Measurements
 348                 Telecommunication Ports Conducted Interference Measurem.
 337    3462D-1      Radiated Measurements 30 MHz to 1 GHz. 3 m / 10 m (OATS)
                                                                                              ISED. Industry Canada
 487    3462D-2      Radiated Measurements 30 MHz to 1 GHz. 3 m (SAR)
                                                                                              Certification and Engineering
 550    3462D-2      Radiated Measurements 1 GHz to 6 GHz. 3 m (SAR)
                                                                                              Bureau
 558    3462D-3      Radiated Measurements above 1 GHz. 3 m (FAR)
 487     R-2666      Radiated Measurements 30 MHz to 1 GHz. 3 m (SAR)
                                                                                              VCCI. Voluntary Control Council
 550     G-301       Radiated Measurements 1 GHz to 6 GHz. 3 m (SAR)
                                                                                              for Interference by Information
 348     C-2914      Mains Ports Conducted Interference Measurements
                                                                                              Technology Equipment. Japan
 348     T-1967      Telecommunication Ports Conducted Interference Measurem.
 OATS = Open Area Test Site. SAR = Semi Anechoic Room. FAR = Fully Anechoic Room




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 22 of 25


9. Instruments and Ancillary
The “Ref.-No” in the left column of the following tables allows the clear identification of the laboratory
equipment.


9.1. Test software and firmware of equipment
  Ref.-No.




                            Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


001          EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
012          Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
013          Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
017          Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
119          RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
261          Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
262          Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
263          Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
                                                                                                    UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
295          Racal Digital Radio Test Set              6103                     1572
                                                                                                    SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                    R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
298          Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                    all band used
323          Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
335          CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
340          Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
366          Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
371          Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
377          EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
378          Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
389          Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                    Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
392          Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                    4.52#002
                                                                                                    R&S Test Firmware Base=5.14, Mess-Software=
436          Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                    GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
441          CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
442          CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                       System CTC-FAR-EMI-
443          CTC-FAR-EMI-RSE                                                    -                   Spuri 7.2.5 or EMC 32 Ver. 9.15.00
                                                       RSE
444          CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 9.15.00
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
460          Univ. Radio Communication Tester          CMU 200                  108901
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used,
489          EMI Test Receiver                         ESU40                    1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
491          ESD Simulator dito                        ESD dito                 dito307022          V 2.30
524          Voltage Drop Simulator                    VDS 200                  0196-16             Software Nr: 000037 Version V4.20a01
526          Burst Generator                           EFT 200 A                0496-06             Software Nr. 000034 Version V2.32
527          Micro Pulse Generator                     MPG 200 B                0496-05             Software-Nr. 000030 Version V2.43
528          Load Dump Simulator                       LD 200B                  0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
546          Univ. Radio Communication Tester          CMU 200                  106436
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                    R&S Test Firmware Base=V5.1403 (current Testsoftw.,
547          Univ. Radio Communication Tester          CMU 200                  835390/014
                                                                                                    f. all band used, GSM = 5.14 WCDMA: = 5.14
584          Spectrum Analyzer                         FSU 8                    100248              2.82_SP3
                                                                                                    R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
597          Univ. Radio Communication Tester          CMU 200                  100347
                                                                                                    not installed, Mainboard= µP1=V.850
607          Signal Generator                          SMR 20                   832033/011          V1.25
620          EMI Test Receiver                         ESU 26                   100362              4.43_SP3
642          Wideband Radio Communication Tester       CMW 500                  126089              Setup V03.26, Test programm component V03.02.20
670          Univ. Radio Communication Tester          CMU 200                  106833              µP1 =V8.50, Firmware = V.20
689          Vector Signal Generator                   SMU200                   100970              02.20.360.142
                                                                                                    CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
692          Bluetooth Tester                          CBT 32                   100236
                                                                                                    RF)




CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 23 of 25



9.2. Single instruments and test systems
 Ref.-No.




                                                                                                                              calibration
                                                                                                                              Interval of



                                                                                                                                                Remark
                           Equipment                             Type               Serial-No.             Manufacturer                                      Cal
                                                                                                                                                             due

001         EMI Test Receiver                         ESS                     825132/017              Rohde & Schwarz         12 M          -            16.05.2019
005         AC - LISN (50 Ohm/50µH, test site 1)      ESH2-Z5                 861741/005              Rohde & Schwarz         12 M          -            16.05.2019
007         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 892563/002              Rohde & Schwarz         12 M          -            16.05.2019
009         Power Meter (EMS-radiated)                NRV                     863056/017              Rohde & Schwarz         24 M          -            15.05.2019
016         Line Impedance Simulating Network         Op. 24-D                B6366                   Spitzenberger+Spies     36 M          -            30.05.2019
021         Loop Antenna (H-Field)                    6502                    9206-2770               EMCO                    36 M          -            30.05.2019
030         Loop Antenna (H-field)                    HFH-Z2                  879604/026              Rohde & Schwarz         36 M          -            30.05.2019
033         RF-current probe (100kHz-30MHz)           ESH2-Z1                 879581/18               Rohde & Schwarz         24 M          -            15.05.2019
057         relay-switch-unit (EMS system)            RSU                     494440/002              Rohde & Schwarz         pre-m         1a
060         power amplifier (DC-2kHz)                 PAS 5000                B6363                   Spitzenberger+Spies     -             3
086         DC - power supply, 0 -10 A                LNG 50-10               -                       Heinzinger Electronic   pre-m         2
087         DC - power supply, 0 -5 A                 EA-3013 S               -                       Elektro Automatik       pre-m         2
091         USB-LWL-Converter                         OLS-1                   007/2006                Ing. Büro Scheiba       -             4
099         passive voltage probe                     ESH2-Z3                 299.7810.52             Rohde & Schwarz         36 M          -            30.05.2021
100         passive voltage probe                     Probe TK 9416           without                 Schwarzbeck             36 M          -            30.05.2021
110         USB-LWL-Converter                         OLS-1                   -                       Ing. Büro Scheiba       -             4
119         RT Harmonics Analyzer dig. Flickermeter   B10                     G60547                  BOCONSULT               36 M          -            30.05.2019
133         horn antenna 18 GHz (Meas 1)              3115                    9012-3629               EMCO                    36 M          1c           10.03.2020
134         horn antenna 18 GHz (Subst 2)             3115                    9005-3414               EMCO                    36 M          -            10.03.2020
136         adjustable dipole antenna (Dipole 1)      3121C-DB4               9105-0697               EMCO                    36 M          -            30.04.2018
248         attenuator                                SMA 6dB 2W              -                       Radiall                 pre-m         2
249         attenuator                                SMA 10dB 10W            -                       Radiall                 pre-m         2
252         attenuator                                N 6dB 12W               -                       Radiall                 pre-m         2
256         attenuator                                SMA 3dB 2W              -                       Radiall                 pre-m         2
257         hybrid                                    4031C                   04491                   Narda                   pre-m         2
260         hybrid coupler                            4032C                   11342                   Narda                   pre-m         2
261         Thermal Power Sensor                      NRV-Z55                 825083/0008             Rohde & Schwarz         24 M          -            30.05.2020
262         Power Meter                               NRV-S                   825770/0010             Rohde & Schwarz         24 M          -            30.05.2019
263         Signal Generator                          SMP 04                  826190/0007             Rohde & Schwarz         36 M          -            30.05.2019
265         peak power sensor                         NRV-Z33, Model 04       840414/009              Rohde & Schwarz         24 M          -            30.05.2020
266         Peak Power Sensor                         NRV-Z31, Model 04       843383/016              Rohde & Schwarz         24 M          -            30.05.2020
267         notch filter GSM 850                      WRCA 800/960-6EEK       9                       Wainwright GmbH         pre-m         2
270         termination                               1418 N                  BB6935                  Weinschel               pre-m         2
271         termination                               1418 N                  BE6384                  Weinschel               pre-m         2
272         attenuator (20 dB) 50 W                   Model 47                BF6239                  Weinschel               pre-m         2
273         attenuator (10 dB) 100 W                  Model 48                BF9229                  Weinschel               pre-m         2
274         attenuator (10 dB) 50 W                   Model 47 (10 dB) 50 W   BG0321                  Weinschel               pre-m         2
275         DC-Block                                  Model 7003 (N)          C5129                   Weinschel               pre-m         2
276         DC-Block                                  Model 7006 (SMA)        C7061                   Weinschel               pre-m         2
279         power divider                             1515 (SMA)              LH855                   Weinschel               pre-m         2
298         Univ. Radio Communication Tester          CMU 200                 832221/091              Rohde & Schwarz         pre-m         3
300         AC LISN (50 Ohm/50µH, 1-phase)            ESH3-Z5                 892 239/020             Rohde & Schwarz         12 M          -            17.05.2019
301         attenuator (20 dB) 50W, 18GHz             47-20-33                AW0272                  Lucas Weinschel         pre-m         2
302         horn antenna 40 GHz (Meas 1)              BBHA9170                155                     Schwarzbeck             36 M          -            14.03.2020
303         horn antenna 40 GHz (Subst 1)             BBHA9170                156                     Schwarzbeck             36 M          -            20.03.2020
331         Climatic Test Chamber -40/+180 Grad       HC 4055                 43146                   Heraeus Vötsch          24 M          -            30.10.2018
341         Digital Multimeter                        Fluke 112               81650455                Fluke                   24 M          -            30.05.2020
342         Digital Multimeter                        Voltcraft M-4660A       IB 255466               Voltcraft               24 M          -            17.05.2019
347         laboratory site                           radio lab.              -                       -                       -             5
348         laboratory site                           EMI conducted           -                       -                       -             5
354         DC - Power Supply 40A                     NGPE 40/40              448                     Rohde & Schwarz         pre-m         2
357         power sensor                              NRV-Z1                  861761/002              Rohde & Schwarz         24 M          -            24.05.2019
371         Bluetooth Tester                          CBT32                   100153                  R&S                     36 M          -            30.05.2019
373         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 100535                  Rohde & Schwarz         12 M          -            17.05.2019
377         EMI Test Receiver                         ESCS 30                 100160                  Rohde & Schwarz         12 M          -            30.05.2019
389         Digital Multimeter                        Keithley 2000           0583926                 Keithley                pre-m         -
                                                                              126.0604.0003.3.3.3.2   LUFFT Mess u.
405         Thermo-/Hygrometer                        OPUS 10 THI                                                             24 M          -            30.03.2019
                                                                              2                       Regeltechnik
431         Model 7405                                Near-Field Probe Set    9305-2457               EMCO                    -             4
436         Univ. Radio Communication Tester          CMU 200                 103083                  Rohde & Schwarz         12 M          -            06.03.2019
439         UltraLog-Antenna                          HL 562                  100248                  Rohde & Schwarz         36 M          -            10.03.2020
454         Oscilloscope                              HM 205-3                9210 P 29661            Hameg                   -             4
456         DC-Power supply 0-5 A                     EA 3013 S               207810                  Elektro Automatik       pre-m         2
459         DC -Power supply 0-5 A , 0-32 V           EA-PS 2032-50           910722                  Elektro Automatik       pre-m         2
460         Univ. Radio Communication Tester          CMU 200                 108901                  Rohde & Schwarz         12 M          -            30.05.2019
463         Universal source                          HP3245A                 2831A03472              Agilent                 -             4
466         Digital Multimeter                        Fluke 112               89210157                Fluke USA               24 M          -            30.05.2020
467         Digital Multimeter                        Fluke 112               89680306                Fluke USA               36 M          -            30.05.2019


CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 24 of 25
 Ref.-No.




                                                                                                                                   calibration
                                                                                                                                   Interval of



                                                                                                                                                     Remark
                             Equipment                           Type                    Serial-No.             Manufacturer                                      Cal
                                                                                                                                                                  due

468         Digital Multimeter                        Fluke 112                   90090455                Fluke USA                36 M          -            30.04.2021
477         ReRadiating GPS-System                    AS-47                       -                       Automotive Cons. Fink    -             3
480         power meter (Fula)                        NRVS                        838392/031              Rohde & Schwarz          24 M          -            16.05.2019
482         filter matrix                             Filter matrix SAR 1         -                       CETECOM (Brl)            -             1d
                                                      System EMI field (SAR)                              ETS Lindgren /
487         System CTC NSA-Verification SAR-EMI                                   -                                                24 M          -            31.03.2019
                                                      NSA                                                 CETECOM
                                                      WRCG 1709/1786-
502         band reject filter                                                    SN 9                    Wainwright               pre-m         2
                                                      1699/1796-
503         band reject filter                        WRCG 824/849-814/859-       SN 5                    Wainwright               pre-m         2
517         relais switch matrix                      HF Relais Box Keithley      SE 04                   Keithley                 pre-m         2
523         Digital Multimeter                        L4411A                      MY46000154              Agilent                  24 M          -            18.05.2019
529         6 dB Broadband resistive power divider    Model 1515                  LH 855                  Weinschel                pre-m         2
530         10 dB Broadband resistive power divider   R 416110000                 LOT 9828                -                        pre-m         2
546         Univ. Radio Communication Tester          CMU 200                     106436                  R&S                      12 M          -            30.03.2018
547         Univ. Radio Communication Tester          CMU 200                     835390/014              Rohde & Schwarz          12 M          -            05.07.2018
549         Log.Per-Antenna                           HL025                       1000060                 Rohde & Schwarz          36/12 M       -            31.07.2018
            System CTC S-VSWR Verification SAR-       System EMI Field SAR S-                             ETS
550                                                                               -                                                24 M          -            30.03.2019
            EMI                                       VSWR                                                Lindgren/CETECOM
                                                      System CTC FAR S-
558         System CTC FAR S-VSWR                                                 -                       CTC                      24 M          -            08.08.2019
                                                      VSWR
574         Biconilog Hybrid Antenna                  BTA-L                       980026L                 Frankonia                36/12 M       -            31.03.2019
584         Spectrum Analyzer                         FSU 8                       100248                  Rohde & Schwarz          pre-m         -
594         Wideband Radio Communication Tester       CMW 500                     101757                  Rohde & Schwarz          12 M          -            30.05.2019
597         Univ. Radio Communication Tester          CMU 200                     100347                  Rohde & Schwarz          pre-m         -
600         power meter                               NRVD (Reserve)              834501/018              Rohde & Schwarz          24 M          -            17.05.2019
601         medium-sensitivity diode sensor           NRV-Z5 (Reserve)            8435323/003             Rohde & Schwarz          24 M          -            15.05.2019
602         peak power sensor                         NRV-Z32 (Reserve)           835080                  Rohde & Schwarz          24 M          -
611         DC power supply                           E3632A                      KR 75305854             Agilent                  pre-m         2
612         DC power supply                           E3632A                      MY 40001321             Agilent                  pre-m         2
613         Attenuator                                R416120000 20dB 10W         Lot. 9828               Radiall                  pre-m         2
616         Digitalmultimeter                         Fluke 177                   88900339                Fluke                    24 M          -            30.05.2020
617         Power Splitter/Combiner                   ZFSC-2-2-S+                 S F987001108            Mini Circuits            -             2
618         Power Splitter/Combiner                   50PD-634                    600994                  JFW Industries USA       -             2
619         Power Splitter/Combiner                   50PD-634                    600995                  JFW Industries, USA      -             3
620         EMI Test Receiver                         ESU 26                      100362                  Rohde-Schwarz            12 M          -            30.05.2019
621         Step Attenuator 0-139 dB                  RSP                         100017                  Rohde & Schwarz          pre-m         2
625         Generic Test Load USB                     Generic Test Load USB       -                       CETECOM                  -             2
                                                                                  201.0999.9302.6.4.1.4
627         data logger                               OPUS 1                                              G. Lufft GmbH            24 M          -            30.03.2019
                                                                                  3
634         Spectrum Analyzer                         FSM (HF-Unit)               826188/010              Rohde & Schwarz          pre-m         2
                                                      HDMI cable with Ethernet
637         High Speed HDMI with Ethernet 1m                                      -                       KogiLink                 -             2
                                                      1m
638         HDMI Kabel with Ethernet 1,5 m flach      HDMI cable with Ethernet    -                       Reichelt                 -             2
640         HDMI cable 2m rund                        HDMI cable 2m rund          -                       Reichelt                 -             2
641         HDMI cable with Ethernet                  Certified HDMI cable with   -                       PureLink                 -             2
642         Wideband Radio Communication Tester       CMW 500                     126089                  Rohde&Schwarz            24 M          -            24.05.2019
644         Amplifierer                               ZX60-2534M+                 SN865701299             Mini-Circuits            -             -
670         Univ. Radio Communication Tester          CMU 200                     106833                  Rohde & Schwarz          24 M          -            30.05.2020
671         DC-power supply 0-5 A                     EA-3013S                    -                       Elektro Automatik        pre-m         2
678         Power Meter                               NRP                         101638                  Rohde&Schwarz            pre-m         -
683         Spectrum Analyzer                         FSU 26                      200571                  Rohde & Schwarz          12 M          -            30.05.2019
                                                                                                          Narda Safety Test
686         Field Analyzer                            EHP-200A                    160WX30702                                       24 M          -            29.03.2019
                                                                                                          Solutions
687         Signal Generator                          SMF 100A                    102073                  Rohde&Schwarz            12 M          -            30.05.2019
688         Pre Amp                                   JS-18004000-40-8P           1750117                 Miteq                    pre-m         -
690         Spectrum Analyzer                         FSU                         100302/026              Rohde&Schwarz            24 M          -            16.05.2019
691         OSP120 Base Unit                          OSP120                      106833                  Rohde & Schwarz          12 M          -            30.05.2019
692         Bluetooth Tester                          CBT 32                      100236                  Rohde & Schwarz          36 M          -            29.05.2020
697         Power Splitter                            ZN4PD-642W-S+               165001445               Mini-Circuits            -             2
                                                      MA 4010-KT080-XPET-         MA4170-KT100-
703         INNCO Antennen Mast                                                                           INNCO                    pre-m         -
                                                      ZSS3                        XPET-
                                                                                  CO3000/933/3841051
704         INNCON Controller                         CO 3000-4port                                       INNCO Systems GmBh       pre-m         -
                                                                                  6/L
711         Harmonic Mixer 90 GHz - 140GHz            RPG FS-Z140                 101004                  RPG                      24 M          -            22.02.2019
712         Harmonic Mixer 75 GHz - 110GHz            FS-Z110                     101468                  Rohde & Schwarz          24 M          -            22.02.2019
713         Harmonic Mixer, 50 GHz - 75GHz            FS-Z75                      101022                  Rohde & Schwarz          24 M          -            22.05.2019
714         Signal Analyzer 67GHz                     FSW67                       104023                  Rohde & Schwarz          24 M          -            28.02.2020
                                                                                                          RPG Radiometer
715         Harmonic Mixer, 140 GHz - 220GHz          FS-Z220                     101009                                           24 M          -            03.08.2019
                                                                                                          Physics
716         Harmonic Mixer 220 GHz to 325 GHZ         FS-Z325                     101005                  RPG Radiometer Physics   24 M          -            13.02.2019
747         Spectrum Analyzer                         FSU 26                      200152                  Rohde & Schwarz          12 M          -            30.05.2019
748         Pickett-Potter Horn Antenna               FH-PP 4060                  010001                  Radiometer Physiscs      -             -
749         Pickett-potter Horn Antenna               FH-PP 60-90                 010003                  Radiometer Physics       -             -


CETECOM_TR18_1_0221601T03a_C1


Test Report 18-1-0221601T03a-C1, Page 25 of 25
 Ref.-No.




                                                                                                                                        calibration
                                                                                                                                        Interval of



                                                                                                                                                          Remark
                           Equipment                             Type                    Serial-No.              Manufacturer                                          Cal
                                                                                                                                                                       due

750         Pickett-Potter Horn Antenna               FH-PP 140-220                010011                   Radiometer Physics          -             -
751         Digital Optical System                    optoCAN-FD Transceiver       17-010416                mk-messtechnik GmbH         -             -
752         Digital Optical System                    optoCAN-FD Transceiver       17-010083                mk-messtechnik GmbH         -             -
753         Digital Optical System                    optoCAN-FD Transceiver       17-010084                mk-messtechnik GmbH         -             -
754         Digital Optical System                    optoCAN-FD Transceiver       17-010415                mk-messtechnik GmbH         -             -
755         Digital Optical System                    optoLAN-100-MAX              17-010795                mk-messtechnik GmbH         -             -
            WIDEBAND RADIO
757                                                   CMW500                       163673                   Rohde&Schwarz               12 M          -            20.07.2018
            COMMUNICATION
758         Signal Generator                          SMU 200A                     100754                   Rohde & Schwarz             24 M          -            11.10.2019
780         Spectrum Analyzer                         FSH3                         101726                   Rohde & Schwarz             12 M          -            19.07.2018
                                                                                                            Elektro-Automatik
781         Power Supply                              PS 2042-10 B                 2815450369                                           -             -
                                                                                                            GmbH
                                                                                                            lektro-Automatik GmbH
782         Power Supply                              PS 2042-10 B                 2815450348                                           -             -
                                                                                                            &Co.KG
783         Spectrum Analyzer                         FSU 26                       100414                   Rohde & Schwarz             12 M          -            30.05.2019
784         Power Supply                              NGSM 32/10                   00196                    Rohde & Schwarz             12 M          -
785         RSP                                       RF Step Attenuator           860712/012               Rohde & Schwarz             12 M          -
786         SAR Probe                                 ES3DV3                       3340                     Speag                       36 M          -            14.02.2021
787         OSP                                       OSP B157WX                   101264                   Rohde & Schwarz             12 M          -            30.05.2019




9.3. Legend

Note / remarks                             Calibrated during system calibration:
                                 1a        System CTC-SAR-EMS (Ref.-No. 442)
                                 1b        System-CTC-EMS-Conducted (Ref.-No. 335)
                                 1c        System CTC-FAR-EMI-RSE (Ref.-No . 443)
                                 1d        System CTC-SAR-EMI (Ref.-No . 441)
                                 1e        System CTC-OATS (EMI radiated) (Ref.-No. 337)
                                 1f        System CTC-CTIA-OTA (Ref.-No . 420)
                                 1g        System CTC-FAR-EMS (Ref.-No . 444)
                                 2         Calibration or equipment check immediately before measurement
                                 3         Regulatory maintained equipment for functional check or support purpose
                                 4         calibrationequipment
                                           Ancillary   of this equipment
                                                                 without has no effect
                                                                         calibration   onmechanical
                                                                                     e.g. measuring result
                                                                                                    equipment or monitoring equipment
                                 5         Test System


Interval of calibration          12 M      12 month
                                 24 M      24 month
                                 36 M      36 month
                                 24/12 M   Calibration every 24 months, between this every 12 months internal validation
                                 36/12 M   Calibration every 36 months, between this every 12 months internal validation
                                 Pre-m     Check before starting the measurement
                                 -         Without calibration



10. Versions of test reports (change history)
            Version             Applied changes                                                                                     Date of release
              --                Inital release                                                                                       2018-12-10
                                Results added for 40MHz bandwidth, FCC/ISED ID added from
                                Cisco router, KDB reference added, KDB relaxing comment added,
               C1                                                                                                                       2018-12-14
                                Table “Applicability of DFS requirements during normal operation”
                                corrected




 END OF TEST REPORT