                                                                       Home Automation System Interface


                                                                       ¤     DC12V, safety voltage
                                                                       ¤     Multiple units can be powered from a single power supply through the RJ45
                                                                             connector.
                                                                       ¤     Specialized RF transmitting antenna allows remode control over larger area
                                                                       ¤     Double RS-485/232 interfaces to connect up to 255pcs gateway controllers.
                                                                       ¤     Dual master dry contact ports for sub-group and group control.
                                                                       ¤     External dry contact switch for local group control.
                                                                       ¤     16 Channel for individual and group control, also able to build up group
                                                                             control of any channel through the Rs485 operation.
                                         EL03-76
                                                                       ¤     Have all transmitters functions
                                                                       ¤     Compatible to all A-OK products




                                                   Working Temp.


         EL03-76                                                                                                                   16 Channels




                                                                                         Lock Channel: If the application takes less than 16 channels, people
                                                                                         can lock the extra channels for easier and flexible operation.
                                                                                        Choose the wanted channel numbers by left and right selecting button, then press and
                                                                                        hold the stop and left or right button on the device for 3 seconds till the locked channel
                                                                                        numbers display, then released them. The same operation to unlock channel.



                                                                                         Local Group Control: to group control all the channel on the
                                                                                         device.
                                                                                        4 wires connection: Press the UP, STOP, DOWN on the device to control all
                                                                                        the channels UP, STOP and DOWN.
                                                                                        3 wires connection: Press the UP, UP+DOWN, DOWN on the device to control
                                                                                        all the channels UP, STOP and DOWN.


RS485/232 central control terminal 1/2                       4 wires   3 wires
                                                                                         RS485/RS232 central control: to control any channel or multiple channels via
RS485/232 central control terminal 1/2
                                                                                         the PC software.


Application Solutions



     USB/RS485 & RS232 transverter




                   EL03-76




                                                                      EL03-76




                                              EL03-76                                    EL03-76




ID Setting      Maximum ID 255, 16 channels




                   Open the softwar, choose    Select the correct serial port         Click "options" at the top of left corner,
                   english language                                                   choose " motor ID and channel settings"




                                                                 Setting successful


FCC Warning

This device complies with part 15 of the FCC Rules. Operation is subject to the following two con
ditions: (1) This device may not cause harmful interference, and (2) this device must accept any i
nterference received, including interference that may cause undesired operation.Any Changes or
 modifications not expressly approved by the party responsible for compliance could void the use
r's authority to operate the equipment. This equipment has been tested and found to comply wit
h the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are desi
gned to provide reasonable protection against harmful interference in a residential installation. T
his equipment generates uses and can radiate radio frequency energy and, if not installed and us
ed in accordance with the instructions, may cause harmful interference to radio communications
. However, there is no guarantee that interference will not occur in a particular installation. If this
 equipment does cause harmful interference to radio or television reception, which can be deter
mined by turning the equipment off and on, the user is encouraged to try to correct the interfere
nce by one or more of the following measures:
-Reorient or relocate the receiving antenna.
-Increase the separation between the equipment and receiver.
-Connect the equipment into an outlet on a circuit different from that to which the receiver is co
nnected.
-Consult the dealer or an experienced radio/TV technician for help.The device has been evaluate
d to meet general RF exposure requirement. The device can be used in portable exposure conditi
on without restriction.


FCC ID: YAV-EL0376



Document Created: 2018-03-09 15:24:09
Document Modified: 2018-03-09 15:24:09

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC