Bay Area Compliance Laboratories Corp. (Shenzhen)                           Report No.: R1DG120904005-00

FCC §1.1307(b) & §2.1093 - RF EXPOSURE
Applicable Standard
According to FCC §2.1093 and §1.1307(b) (1), systems operating under the provisions of this section shall
be operated in a manner that ensure that the public is not exposed to radio frequency energy level in excess
of the Commission’s guideline.

According to FCC KDB 447498 D01 Mobile Portable RF Exposure v04 section 5, Push-to-talk (PTT)
devices:

a) RF exposure is evaluated with a duty factor of 50% when the actual operating duty factor is ≤ 50%.
Devices supporting higher duty factors shall be evaluated at the maximum duty factor; for example,
devices supporting operator-assisted PSTN calls. Contact the FCC Laboratory when unable to test a device
at the required duty factor due to hardware limitations or other reasons.

b) Portable PTT devices

i) The power thresholds and operating conditions in Table 1 are used to determine SAR test requirements
for PTT radios required to comply with the general population exposure limit. When the occupational
exposure limit applies, these power thresholds are increased by a factor of five (5) to determine the test
requirements. SAR is required for PTT devices with maximum output power greater than these
thresholds.28 SAR evaluation is also required for separation distances smaller than those in Table 1.
Contact the FCC Laboratory to determine if SAR evaluation is necessary for other frequencies or when the
SAR is very low.




SAR Evaluation Power Thresholds for PTT devices,f≤0.5GHz
        Exposure Conditions         mW (for uncontrolled)                 mW (for occupational)
         Held to face ≥2.5cm                250                                  1250
         Body-worn ≥1.5cm                   200                                  1000
         Body-worn ≥1.0cm                   150                                   750

ii) Additional SAR evaluation with a SAM phantom is required for PTT devices with held-to-ear operating
mode.29 Contact the FCC Laboratory for device operating and test configurations.

Routine SAR evaluation refers to that specifically required by §2.1093, using measurements or computer
simulation. When routine SAR evaluation is not required, portable transmitters with output power greater
than the applicable low threshold require SAR evaluation to qualify for TCB approval.




FCC Part 90                                                                                   Page 8 of 37


Bay Area Compliance Laboratories Corp. (Shenzhen)                          Report No.: R1DG120904005-00

Result:
1. The distance between the antenna and the users is 2.3cm for boby worn,and 2.5cm for face
2. The output power:

                                                    Average                   Average
                                   Peak
                 Frequency                          Output    Duty Cycle      Output
    Mode                       Output Power                                                 Comments
                   (MHz)                             Power       (%)           Power
                                  (dBm)
                                                     (mW)                      (mW)
                    136.5          30.00             1000       50.00           500         High Power
                    138.5          30.00             1000       50.00           500         High Power
                    146.5          30.40             1096       50.00           603         High Power
  Analog            147.5          30.45             1109       50.00           616         High Power
 Modulation         155.5          30.24             1057       50.00           560         High Power
   (FM)
                    159.5          30.53             1130       50.00           638         High Power
                    160.5          30.52             1127       50.00           637         High Power
                    167.5          30.36             1086       50.00           592         High Power
                    173.5          30.07             1016       50.00           518         High Power
                    136.5          30.01             1002       49.68           498         High Power
                    138.5          30.01             1002       49.68           498         High Power
                    146.5          30.43             1104       49.68           603         High Power
  Digital           147.5          30.49             1119       49.68           623         High Power
 Modulation         155.5          30.25             1059       49.68           558         High Power
  (4FSK)
                    159.5          30.57             1140       49.68           646         High Power
                    160.5          30.57             1140       49.68           646         High Power
                    167.5          30.39             1094       49.68           592         High Power
                    173.5          30.08             1019       49.68           516         High Power




FCC Part 90                                                                                Page 9 of 37


Bay Area Compliance Laboratories Corp. (Shenzhen)                                                                       Report No.: R1DG120904005-00

                                                    RBW 100 kHz                                                                 RBW 100 kHz   Delta 2 [T1 ]
                                                    VBW 300 kHz                                                                 VBW 300 kHz               8.91 dB
        Ref    35 dBm           * Att   40 dB       SWT 200 ms                  Ref    35 dBm               * Att   40 dB       SWT 100 ms           29.800000 ms
              Offset    10 dB                                                         Offset    10 dB                                         Marker 1 [T1 ]
        30                                                                      30                                                                      -39.25   dBm
                                                                   B                                                                                                    B
                                                                                                                                                     27.800000   ms
                                                                  SGL                                                                                                  SGL
                                                                                                                                              Delta 1 [T1 ]
1 AP    20                                                              1 AP    20
CLRWR                                                                                                                                                     3.38   dB
                                                                        CLRWR
                                                                  LVL                                                                                60.000000   ms    LVL
        10                                                                      10



        0                                                                       0
                                                                  PS                                                                                                   PS


        -10                                                                     -10



        -20                                                       3DB           -20                                                                                    3DB
                                                                  AC                                                                                                   AC
                                                                                                                                     2
        -30                                                                     -30
                                                                                                                                                         1
                                                                                                        1
        -40                                                                     -40



        -50                                                                     -50



        -60                                                                     -60


        Center 156 MHz                          20 ms/                          Center 156 MHz                              10 ms/




Date: 21.DEC.2012           18:52:09                                    Date: 21.DEC.2012           18:53:16




Note: duty cycle=Ton/Tp=29.8ms/60ms=0.4968 (49.68%) for 4FSK modulation, worst case at data
transmiting mode

Conclusion:

  The maximum time-averaged output power is 646 mW <the exclusion thresholds is 1000 mW

  According to FCC KDB 447498 D01 Mobile Portable RF Exposure v04 section 5, Push-to-talk (PTT)
  devices, the SAR evaluation is not required.




FCC Part 90                                                                                                                                              Page 10 of 37