RF Exposure Info

FCC ID: Y22-S7FBZ

RF Exposure Info

Download: PDF
FCCID_4488407

                                 SGS-CSTC Standards Technical Services Co., Ltd.
                                 Shenzhen Branch




                                                                    Report No.: SZEM190601533802
                                                                    Page:        1 of 10


1     COVER PAGE

                       Human Exposure Report
Application No.:               SZEM1906015338CR
Applicant:                     SKULLCANDY, INC.
Address of Applicant:          6301 N Landmark Dr Park City 84098, Utah United States of America
Manufacturer:                  SKULLCANDY, INC.
Address of Manufacturer:       6301 N Landmark Dr Park City 84098, Utah United States of America
Equipment Under Test (EUT):
EUT Name:                      Fuelbase Wireless Charge Pad
Model No.:                     S7FBZ


Trade mark:
                               Skullcandy
FCC ID:                        Y22- S7FBZ
Standards:                     47 CFR PART 1, Subpart I, Section 1.1310
Date of Receipt:               2019-06-18
Date of Test:                  2019-06-20 to 2019-06-23
Date of Issue:                 2019-08-05
Test Result :                    Pass*
* In the configuration tested, the EUT complied with the standards specified above




           Keny Xu
     EMC Laboratory Manager


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Shenzhen Branch
                                                          Report No.: SZEM190601533802
                                                          Page:       2 of 10




                                        Revision Record
     Version       Chapter              Date                 Modifier       Remark

     01                              2019-08-05                             Original




Authorized for issue by:




                             Benson Wang /Project Engineer




                             Eric Fu /Reviewer


                                              SGS-CSTC Standards Technical Services Co., Ltd.
                                              Shenzhen Branch
                                                                                                    Report No.: SZEM190601533802
                                                                                                    Page:       3 of 10




2         Contents
1      COVER PAGE ............................................................................................................................................1

2      CONTENTS ................................................................................................................................................3

3      GENERAL INFORMATION ........................................................................................................................4
    3.1        DETAILS OF E.U.T. ...............................................................................................................................4
    3.2        DESCRIPTION OF SUPPORT UNITS .........................................................................................................4
    3.3        TEST LOCATION ...................................................................................................................................5
    3.4        TEST FACILITY .....................................................................................................................................5
    3.5        DEVIATION FROM STANDARDS ...............................................................................................................5
    3.6        ABNORMALITIES FROM STANDARD CONDITIONS .....................................................................................5
4      EQUIPMENTS USED DURING TEST ........................................................................................................6

5      TEST RESULTS .........................................................................................................................................7
    5.1     RF EXPOSURE TEST .............................................................................................................................7
       5.1.1 E.U.T. Operation ............................................................................................................................7
       5.1.2 Measurement Data ........................................................................................................................8
6      PHOTOGRAPHS ......................................................................................................................................10
    6.1        TEST SETUP PHOTOS .................................................................................................................... 10-13


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Shenzhen Branch
                                                               Report No.: SZEM190601533802
                                                               Page:       4 of 10




3     General Information
3.1     Details of E.U.T.
      Power supply:          INPUT: 5V/2A 9V/1.8A ;
                             OUTPUT:5W/7.5W/10W 10W(MAX)
      Cable:                 Type-C cable: 123cm shielded
      Operation Frequency:   114.103kHz to 149.519kHz
      Modulation Type:       Load modulation
      Antenna Type:          Loop antenna
      Antenna Gain:          0dBi
      Remark:                This device has been tested the worst status of full load and the device has
                             been tested with load at 5W, 7.5W and 10W,the worst case 10W is reported
                             only.



3.2    Description of Support Units

      Description                Manufacturer               Model No.                  Serial No.
      Adapter                        SAMSUNG                EP-TA200              R37J8YA7W71DK3
      SAMSUNG Galaxy S8              SAMSUNG                SM-G9500                R28J9140LPB
      iPhone 8                         Apple                 A1863                 F4GVQ656JC6D


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                                  Report No.: SZEM190601533802
                                                                  Page:       5 of 10




3.3    Test Location
      All tests were performed at:
      SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen Branch E&E Lab,
      No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen, Guangdong,China
      518057.
      Tel: +86 755 2601 2053          Fax: +86 755 2671 0594
      No tests were sub-contracted.

3.4    Test Facility
      The test facility is recognized, certified, or accredited by the following organizations:
      • CNAS (No. CNAS L2929)
      CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC
      Lab to ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration
      Laboratories (CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration
      Laboratories) for the competence in the field of testing.
      • A2LA (Certificate No. 3816.01)
      SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
      American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
      • VCCI
      The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz,
      Shielded Room for Mains Port Conducted Interference Measurement and Telecommunication Port
      Conducted Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have
      been registered in accordance with the Regulations for Voluntary Control Measures with Registration
      No.: G-20026, R-14188, C-12383 and T-11153 respectively.
      • FCC –Designation Number: CN1178
      SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
      as an accredited testing laboratory.
      Designation Number: CN1178. Test Firm Registration Number: 406779.
      • Innovation, Science and Economic Development Canada
      SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized
      by ISED as an accredited testing laboratory.
      CAB identifier: CN0006.
      IC#: 4620C.

3.5    Deviation from Standards
      None.

3.6    Abnormalities from Standard Conditions
      None.


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                           Report No.: SZEM190601533802
                                                           Page:       6 of 10




4      Equipments Used during Test
Item       Equipment          Manufacturer   Model No   Inventory No    Cal Date    Cal Due Date

       Electric Field Probe   WANDEL     &
 1                                           EMR-20     EMC0907        2019-05-21   2020-05-20
       (100KHz-3GHz)          GOLTERMANN
 2     EMF Tester             Narda          ELT-400    SZE039-4       2019-07-08   2020-07-07


                                  SGS-CSTC Standards Technical Services Co., Ltd.
                                  Shenzhen Branch
                                                                      Report No.: SZEM190601533802
                                                                      Page:       7 of 10




5       Test Results
5.1       RF Exposure test
        Test Requirement:               47 CFR PART 1, Subpart I, Section 1.1310
        Measurement Distance:           15cm
        Limit:

    Frequency range Electric field strength Magnetic field strength Power density Averaging time
         (MHz)               (V/m)                  (A/m)             (mW/cm2)      (minutes)
                              (A) Limits for Occupational/Controlled Exposures
           0.3-3.0                 614                      1.63                *(100)             6
           3.0-30                1842/f                    4.89/f              *(900/f2)           6
           30-300                 61.4                     0.163                   1.0             6
          300-1500                  /                         /                  f/300             6
        1500-100,000                /                         /                    5               6
                          (B) Limits for General Population/Uncontrolled Exposure
          0.3-1.34                 614                      1.63                *(100)             30
           1.34-30                824/f                    2.19/f              *(180/f2)           30
           30-300                 27.5                     0.073                   0.2             30
          300-1500                  /                         /                 f/1500             30
        1500-100,000                /                         /                    1.0             30
    F=frequency in MHz
    *=Plane-wave equivalent power density
    RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC rules.
    The emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits for
    150kHz:614V/m,1.63A/m).
5.1.1     E.U.T. Operation

        Operating Environment:
        Temperature:      24.5 C           Humidity:    52 % RH         Atmospheric Pressure: 1015 mbar

        EUT Operation:
        This device has been tested the worst status of full load and the device has been tested with mobile
         phone at zero charge, intermediate charge, and full charge.


                              SGS-CSTC Standards Technical Services Co., Ltd.
                              Shenzhen Branch
                                                            Report No.: SZEM190601533802
                                                            Page:       8 of 10




5.1.2   Measurement Data
        The max output power =10W
        Electric Field Emissions
           Operation      Test Distance   Test Position   Probe Measure   50% Limit
           frequency                                       Result (V/m)
                              (cm)                                          (V/m)
                                             Side 1           2.69          307
                                             Side 2           1.47          307
            116 kHz            15            Side 3           2.51          307
                                             Side 4           1.19          307
                                              Top             0.75          307


        Magnetic Field Emissions
           Operation      Test Distance   Test Position   Probe Measure   50% Limit
           frequency                                       Result (A/m)
                              (cm)                                          (A/m)
                                             Side 1          0.1152         0.815
                                             Side 2          0.0539         0.815
            116 kHz            15            Side 3          0.0989         0.815
                                             Side 4          0.0623         0.815
                                              Top            0.0248         0.815


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Shenzhen Branch
                                                    Report No.: SZEM190601533802
                                                    Page:       9 of 10



Mobile phone has been charge at zero charge, intermediate charge, and full charge.

Electric Field Emissions

 Operation       Test                     Probe Measure Result(V/m)
                              Test                                        50%Limit
 frequency     Distance
                             Position    zero    intermediate     full
                                        charge      charge      charge      (V/m)
                  (cm)
                              Side 1     2.96        2.72        2.52        307
                              Side 2     1.75        1.57        1.32        307
  116 kHz          15         Side 3     2.82        2.58         2.4        307
                              Side 4     1.48        1.24        1.04        307
                               Top       1.04        0.86        0.62        307


Magnetic Field Emissions

 Operation       Test                     Probe Measure Result(A/m)
                              Test                                        50%Limit
 frequency     Distance
                             Position   zero     intermediate   full
                                        charge      charge      charge      (A/m)
                  (cm)
                              Side 1    0.1278      0.1131      0.0994      0.815
                              Side 2    0.0651      0.0541      0.0391      0.815
  116 kHz          15         Side 3    0.1084      0.0976      0.0837      0.815
                              Side 4    0.0747      0.0614      0.0462      0.815
                               Top      0.0358      0.0257      0.0215      0.815


                               SGS-CSTC Standards Technical Services Co., Ltd.
                               Shenzhen Branch
                                                              Report No.: SZEM190601533802
                                                              Page:       10 of 10




6     Photographs
6.1    Test setup photos
Please refer to setup photos




                                      - End of the Report -



Document Created: 2019-10-21 09:52:34
Document Modified: 2019-10-21 09:52:34

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC