Test Report

FCC ID: XXMOM12001100

Test Report

Download: PDF
FCCID_1773788

FCC Measurement/Technical Report on
RFID transceiver
NXP automotive module OM12001

Report Reference: MDE_NXP_1201_FCCd




Error! Not a valid link.


Table of Contents

0 Summary                                            3
  0.1     Technical Report Summary                    3
  0.2     Measurement Summary                         4

1 Administrative Data                                5
  1.1     Testing Laboratory                          5
  1.2     Project Data                                5
  1.3     Applicant Data                              5
  1.4     Manufacturer Data                           5

2 Test object Data                                   6
  2.1     General EUT Description                     6
  2.2     EUT Main components                         7
  2.3     Ancillary Equipment                         7
  2.4     Auxiliary Equipment                         7
  2.5     EUT Setups                                  8
  2.6     Operating Modes                             8
  2.7     Special software used for testing           8
  2.8     Product labelling                           8

3 Test Results                                       9
  3.1     Spurious radiated emissions                 9
  3.2     Occupied bandwidth                         13
  3.3     Spectrum mask                              14
  3.4     Frequency tolerance                        15

4 Test Equipment                                    17
5 Photo Report                                      25
6 Setup Drawings                                    25
7 FCC and IC Correlation of measurement requirements 26
8 Annex measurement plots                           27
  8.1     Radiated emissions                         27
  8.2     Occupied bandwidth                         30
  8.3     Spectrum mask                              32




Test report Reference: MDE_NXP_1201_FCCd             Page 2 of 32


0     Summary
0.1 Technical Report Summary

Type of Authorization
Certification for an intentional radiator operating at 13.56 MHz

Applicable FCC Rules

Prepared in accordance with the requirements of FCC Rules and Regulations as listed in
47 CFR Ch.1 Parts 2 (10-1-11 Edition) and 15 (10-1-11 Edition). The following subparts
are applicable to the results in this test report.


Part 2, Subpart J - Equipment Authorization Procedures, Certification

Part 15, Subpart C – Intentional Radiators

§ 15.205    Restricted bands of operation

§ 15.207    Conducted limits

§ 15.209    Radiated emission limits; general requirements

§ 15.215    Additional provisions to the general radiated emission limitations

§ 15.225    Operation within the band 13.110-14.010 MHz




Summary Test Results:

The EUT complied with all performed tests as listed in chapter 0.2 Measurement
Summary.




Test report Reference: MDE_NXP_1201_FCCd                                         Page 3 of 32


0.2 Measurement Summary

FCC Part 15, Subpart C                § 15.207
Conducted Emissions AC Power line
The measurement was performed according to ANSI C63.4                                      2009
OP-Mode            Setup              Port                                                 Final Result
op-mode 1          Setup_01           AC port (power line)                                 N/A

FCC Part 15, Subpart C                §15.209
Radiated Emissions
The measurement was performed according to ANSI C63.4                                      2009
OP-Mode            Setup              Port                                                 Final Result
op-mode 1          Setup_01           Enclosure                                            passed

FCC Part 15, Subpart C                § 15.215
Occupied Bandwidth
The measurement was performed according to FCC § 2.1049                                    10-1-11 Edition
OP-Mode            Setup              Port                                                 Final Result
op-mode 1          Setup_02           Enclosure                                            passed

FCC Part 15, Subpart C                § 15.225
Spectrum Mask
The measurement was performed according to ANSI C63.4                                      2009
OP-Mode           Setup               Port                                                 Final Result
op-mode 1         Setup_01            Enclosure                                            passed

FCC Part 15, Subpart C                § 15.225
Frequency Tolerance
The measurement was performed according to FCC § 2.1055                                    10-1-11 Edition
OP-Mode             Setup             Port                                                 Final Result
op-mode 2           Setup_01          Enclosure                                            passed


N/A     not applicable (the EUT is powered by DC)




                                 Digitally signed by Andreas Petz                                  Digitally signed by Marco Kullik
                                 DN: cn=Andreas Petz, sn=Petz,                                     DN: cn=Marco Kullik, sn=Kullik,
                                 givenName=Andreas, o=7Layers AG,                                  givenName=Marco, o=7 Layers AG,
                                 serialNumber=001000000001202918000                                serialNumber=001000000001202905000

Responsible for                  1, email=andreas.petz@7layers.de
                                 Reason: I am approving this document   Responsible                2, email=Marco.Kullik@7Layers.de
                                                                                                   Reason: I am the author of this document

Accreditation Scope:             Date: 2012.07.27 15:32:37 +02'00'
                                                                        for Test Report:           Date: 2012.07.27 15:30:11 +02'00'




Test report Reference: MDE_NXP_1201_FCCd                                                                            Page 4 of 32


1     Administrative Data
1.1 Testing Laboratory

Company Name:                              7Layers AG

Address                                    Borsigstr. 11
                                           40880 Ratingen
                                           Germany

This facility has been fully described in a report submitted to the FCC and accepted
under the registration number 96716.

The test facility is also accredited by the following accreditation organisation:
Laboratory accreditation no.:                DAkkS D-PL-12140-01-01

Responsible for Accreditation Scope:       Dipl.-Ing. Bernhard Retka
                                           Dipl.-Ing. Robert Machulec
                                           Dipl.-Ing. Andreas Petz

Report Template Version:                   2012-03-14

1.2 Project Data

Responsible for testing and report:        Dipl.-Ing. Marco Kullik

Date of Test(s):                           2012-06-06 to 2012-07-26
Date of Report:                            2012-07-26

1.3 Applicant Data

Company Name:                              NXP Semiconductors

Address:                                   2 esplanade Anton Philips, Campus
                                           EffiScience, Colombelles BP2000
                                           14906 Caen Cedex 9
                                           France

Contact Person:                            Mr. Hugues de Perthuis

1.4 Manufacturer Data
Company Name:                              please see applicant data

Address:


Contact Person:




Test report Reference: MDE_NXP_1201_FCCd                                            Page 5 of 32


2     Test object Data
2.1 General EUT Description

Equipment under Test                   RFID transceiver
Type Designation:                      OM12001
Kind of Device:                        RFID transceiver operating at 13.56 MHz
(optional)
Voltage Type:                          DC

Voltage level:                         3.4 V / 4.2 V / 4.8 V


General product description:

The OM12001 is a 13.56 MHz contactless smartcard reader and encoder for PC for
reading RFID tags.


Specific product description for the EUT:

The EUT is a module, which can be built-in, various devices, and includes the
technologies: GSM, GPS, RFID.


The EUT provides the following ports:

Ports
Enclosure
GPS antenna port
GSM antenna port
Power and control connector


The main components of the EUT are listed and described in Chapter 2.2.




Test report Reference: MDE_NXP_1201_FCCd                                         Page 6 of 32


2.2 EUT Main components

Type, S/N, Short Descriptions etc. used in this Test Report

   Short      Equipment         Type         Serial No.    HW Status     SW Status      Date of
Description   under Test     Designation                                                Receipt
EUT A         NXP            OM12001        B23E4#038     B2.3           7.4.4        2012-05-10
(Code:        automotive
CS020g01)     module
              OM12001

Remark: EUT A is equipped with an external loop antenna (NXP PCB1948-1, 41-10).

NOTE: The short description is used to simplify the identification of the EUT in this test
report.


2.3 Ancillary Equipment

For the purposes of this test report, ancillary equipment is defined as equipment which is
used in conjunction with the EUT to provide operational and control features to the EUT.
It is necessary to configure the system in a typical fashion, as a customer would normally
use it. But nevertheless Ancillary Equipment can influence the test results.

   Short      Equipment          Type        Serial No.    HW Status     SW Status        FCC ID
Description   under Test     Designation
AE 1          RFID tag       Mifare® 4K     –             –             –             –
AE 2          RFID           NXP            NXP           –             –
              antenna        PCB1948-1      PCB1948-1



2.4 Auxiliary Equipment

For the purposes of this test report, auxiliary equipment is defined as equipment which is
used temporarily to enable operational and control features especially used for the tests
of the EUT which is not used during normal operation or equipment that is used during
the tests in combination with the EUT but is not subject of this test report. It is necessary
to configure the system in a typical fashion, as a customer would normally use it.
But nevertheless Auxiliary Equipment can influence the test results.

   Short       Equipment        Type         Serial no.    HW Status     SW Status        FCC ID
Description    under Test    Designation
AUX 1             AC/DC           –              –               –               –.         –
                  supply
AUX 2              GSM            –              –               –               –          –
                antenna
AUX 3              GPS         GAACZ-A           –               –               –          –
                antenna
                 (active)




Test report Reference: MDE_NXP_1201_FCCd                                                     Page 7 of 32


2.5 EUT Setups

This chapter describes the combination of EUTs and equipment used for testing. The
rationale for selecting the EUTs, ancillary and auxiliary equipment and interconnecting
cables, is to test a representative configuration meeting the requirements of the
referenced standards.

Setup No.    Combination of EUTs                        Description
Setup_01      EUT A + AE 1+ AE 2 +               setup for EUT reading a tag
             AUX 1 + AUX 2 + AUX 3



2.6 Operating Modes

This chapter describes the operating modes of the EUTs used for testing.

Op. Mode    Description of Operating Modes     Remarks
op-mode 1   CW carrier signal                 EUT is transmitting a periodic CW signal and is
                                              continuously reading TAG information
                                              (modulated signal).



2.7     Special software used for testing

None.

2.8     Product labelling

2.8.1    FCC ID label
Please refer to the documentation of the applicant.


2.8.2    Location of the label on the EUT
Please refer to the documentation of the applicant.




Test report Reference: MDE_NXP_1201_FCCd                                                Page 8 of 32


3     Test Results

3.1 Spurious radiated emissions

Standard       FCC Part 15, 10-1-11 Edition Subpart C

The test was performed according to: ANSI C63.4–2009


3.1.1 Test Description

The test set-up was made in accordance to the general provisions of ANSI C63.4–2009 in
a typical installation configuration. The Equipment Under Test (EUT) was set up on a non-
conductive table 1.0 x 2.0 m² in the semi-anechoic chamber. The influence of the EUT
support table that is used between 30–1000 MHz was evaluated.
The measurement procedure is implemented into the EMI test software ES-K1 from R&S.
Exploratory tests are performed at 3 orthogonal axes to determine the worst-case
orientation of a body-worn or handheld EUT. The final test on all kind of EUTs is
performed at 2 axes.

1. Measurement up to 30 MHz
The Loop antenna HFH2-Z2 is used.
Step 1: pre measurement
- Anechoic chamber
- Antenna distance: 10 m
- Detector: Peak-Maxhold
- Frequency range: 0.009 – 0.15 and 0.15 – 30 MHz
- Frequency steps: 0.1 kHz and 5 kHz
- IF–Bandwidth: 0.2 kHz and 10 kHz
- Measuring time / Frequency step: 100 ms
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.
Step 2: final measurement
For the relevant emissions determined in step 1, an additional measurement with the
following settings will be performed. Intention of this step is to find the maximum
emission level.
- Open area test side
- Antenna distance: according to the Standard
- Detector: Quasi-Peak
- Frequency range: 0.009 – 30 MHz
- Frequency steps: measurement at frequencies detected in step 1
- IF–Bandwidth: 200 Hz – 10 kHz
- Measuring time / Frequency step: 100 ms




Test report Reference: MDE_NXP_1201_FCCd                                         Page 9 of 32


2. Measurement above 30 MHz and up to 1 GHz
Step 1: Preliminary scan
Preliminary test to identify the highest amplitudes relative to the limit.
Settings for step 1:
- Antenna distance: 3 m
- Detector: Peak-Maxhold
- Frequency range: 30 – 1000 MHz
- Frequency steps: 60 kHz
- IF–Bandwidth: 120 kHz
- Measuring time / Frequency step: 100 µs
- Turntable angle range: –180° to 180°
- Turntable step size: 90°
- Height variation range: 1 – 3 m
- Height variation step size: 2 m
- Polarisation: Horizontal + Vertical
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.
Step 2: second measurement
For the relevant emissions determined in step 1, an additional measurement with the
following settings will be performed. Intention of this step is, to find out the approximate
turntable angle and antenna height for each frequency.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: –180° to 180°
- Turntable step size: 45°
- Height variation range: 1 – 4 m
- Height variation step size: 0.5 m
- Polarisation: horizontal + vertical
After this step the EMI test system has determined the following values for each
frequency (of step 1):
- Frequency
- Azimuth value (of turntable)
- Antenna height
The last two values have now the following accuracy:
- Azimuth value (of turntable): 45°
- Antenna height: 0.5 m
Step 3: final measurement
In this step the accuracy of the turntable azimuth and antenna height will be improved.
This is necessary to find out the maximum value of every frequency.
For each frequency, which was determined the turntable azimuth and antenna height will
be adjusted. The turntable azimuth will be slowly varied by +/– 22.5° around this value.
During this action the value of emission is continuously measured. The turntable azimuth
at the highest emission will be recorded and adjusted. In this position the antenna height
is also slowly varied by +/– 25 cm around the antenna height determined. During this
action the value of emission is also continuously measured. The antenna height of the
highest emission will also be recorded and adjusted.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: –22.5° to +22.5° around the determined value
- Height variation range: –0.25 m to +0.25 m around the determined value




Test report Reference: MDE_NXP_1201_FCCd                                         Page 10 of 32


Step 4: final measurement with QP detector
With the settings determined in step 3, the final measurement will be performed:
EMI receiver settings for step 4:
- Detector: Quasi-Peak(< 1 GHz)
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 1 s

After the measurement a plot will be generated which contains a diagram with the results
of the preliminary scan and a chart with the frequencies and values of the results of the
final measurement.

3. Measurement above 1 GHz
The following modifications apply to the measurement procedure for the frequency range
above 1 GHz:
The Equipment Under Test (EUT) was set up on a non-conductive support at 1.4 m
height in the fully-anechoic chamber. The measurement distance was reduced to 1 m.
The results were extrapolated by the extrapolation factor of 20 dB/decade (inverse linear
distance for field strength measurements, inverse linear-distance squared for the power
reference level measurements). Due to the fact that in this frequency range a double
ridged wave guided horn antenna (up to 18 GHz) and a horn antenna (18-25 GHz) are
used, the steps 2-4 are omitted. Step 1 was performed with one height of the receiving
antenna only.
EMI receiver settings:
- Detector: Peak, Average
- IF Bandwidth = 1 MHz


3.1.2 Test Requirements / Limits
FCC Part 15, Subpart C, §15.247 (d)
... In addition, radiated emissions which fall in the restricted bands, as defined in Section
15.205(a), must also comply with the radiated emission limits specified in Section
15.209(a) (see Section 15.205(c)).

FCC Part 15, Subpart C, §15.209, Radiated Emission Limits

Frequency in MHz        Limit (µV/m)         Measurement distance (m)   Limit(dBµV/m @10m)
0.009 – 0.49            2400/F(kHz)          300                        Limit (dBµV/m)+30dB
0.49 – 1.705            24000/F(kHz)         30                         Limit (dBµV/m)+10dB
1.705 – 30              30                   30                         Limit (dBµV/m)+10dB

Frequency in MHz         Limit (µV/m)        Measurement distance (m)   Limit (dBµV/m)
30 – 88                  100                 3                          40.0
88 – 216                 150                 3                          43.5
216 – 960                200                 3                          46.0
above 960                500                 3                          54.0


§15.35(b)
..., there is also a limit on the radio frequency emissions, as measured using
instrumentation with a peak detector function, corresponding to 20 dB above
the maximum permitted average limit....

Used conversion factor: Limit (dBµV/m) = 20 log (Limit (µV/m)/1µV/m)




Test report Reference: MDE_NXP_1201_FCCd                                           Page 11 of 32


3.1.3 Test Protocol

Temperature:          23 – 27 °C
Air Pressure:         1000 – 1006 hPa
Humidity:             40 – 41 %


3.1.3.1 Measurement up to 30 MHz

Op. Mode              Setup                         Port
op-mode 1             Setup_01                      Enclosure

  Polari-     Frequency           Corrected value           Limit    Limit      Limit   Delta to   Delta to
  sation         MHz                 dBµV/m                dBµV/    dBµV/      dBµV/      limit     limit
                                                              m        m          m         dB        dB
                             QP        Peak     AV           QP      Peak        AV     QP/Peak      AV

    0°            –           –         –           –        –        –          –         –          –
    90°           –           –         –           –        –        –          –         –          –

Remark: No (further) spurious emissions in the range 20 dB below the limit found therefore step 2 was not
        performed. Please refer to the plot in the annex.
        The found peak at 99.5 kHz is an emission from loop antenna power supply, and the peak found at
        13.56 MHz is the wanted signal of the EUT.



3.1.3.2 Measurement above 30 MHz

Op. Mode              Setup                         Port
op-mode 1             Setup_01                      Enclosure

  Polari-     Frequency           Corrected value           Limit    Limit      Limit   Delta to   Delta to
  sation         MHz                 dBµV/m                dBµV/    dBµV/      dBµV/      limit     limit
                                                              m        m          m         dB        dB
                             QP        Peak     AV           QP      Peak        AV     QP/Peak      AV

  Vertical      36.84       31.1        –           –       40.0      –          –         8.9        –
  Vertical      40.68       20.10       –           –       40.0      –          –        19.9        –
  Vertical      67.80        8.4        –           –       40.0      –          –        31.6        –
 Horizontal    135.60        7.5        –           –       43.5      –          –        36.0        –
  Vertical     150.00        27.6       –           –       43.5      –          –        15.9        –
  Vertical     176.28         7.3       –           –       43.5      –          –        36.2        –
  Vertical     250.02        39.8       –           –       46.0      –          –        6.2         –
 Horizontal    349.95       45.8        –           –       46.0      –          –        0.2         –
 Horizontal    400.02       43.1        –           –       46.0      –          –        2.9         –
 Horizontal    499.98       43.9        –           –       46.0      –          –        2.1         –

Remark: No (further) spurious emissions in the range 20 dB below the limit found.




3.1.4 Test result: Spurious radiated emissions
                        FCC Part 15, Subpart C          Op. Mode             Result
                                                        op-mode 1            passed




Test report Reference: MDE_NXP_1201_FCCd                                                           Page 12 of 32


3.2    Occupied bandwidth

Standard        FCC Part 15, 10-1-11 Edition Subpart C

The test was performed according to: FCC §15.31

3.2.1 Test Description
The Equipment Under Test (EUT) was setup in a shielded room to perform the occupied
bandwidth measurements.
The reference level is the level of the highest amplitude signal observed from the
transmitter at either the fundamental frequency or first-order modulation products in all
typical modes of operation, including the unmodulated carrier, even if atypical.
The results recorded were measured with the modulation which produces the worst-case
(widest) occupied bandwidth.


3.2.2 Test Requirements / Limits
FCC Part 15, Subpart C, §15.215 (c)
Intentional radiators operating under the alternative provisions to the general emission
limits, as contained in §§ 15.217 through 15.257 and in Subpart E of this part, must be
designed to ensure that the 20 dB bandwidth of the emission, or whatever bandwidth
may otherwise be specified in the specific rule section under which the equipment
operates, is contained within the frequency band designated in the rule section under
which the equipment is operated. …


3.2.3 Test Protocol

Temperature:        °C
Air Pressure:       hPa
Humidity:           %

Op. Mode           Setup                     Port
op-mode 1          Setup_02                  Enclosure

    20 dB bandwidth               99% bandwidth                         Remarks
          kHz                          kHz
        288.577                      501.002             The 20 dB bandwidth from 13.415712 MHz
                                                          to 13.704289 MHz is contained within the
                                                         designated frequency band 13.110 MHz to
                                                                       14.010 MHz.

Remark: Please see annex for the measurement plot.




3.2.4 Test result: Occupied bandwidth
                FCC Part 15, Subpart C    Op. Mode                 Result
                                          op-mode 1                passed




Test report Reference: MDE_NXP_1201_FCCd                                                   Page 13 of 32


3.3 Spectrum mask

Standard        FCC Part 15, 10-1-11 Edition Subpart C

The test was performed according to: FCC §15.225

3.3.1 Test Description

The test set-up was made in accordance to the general provisions of ANSI C 63.4–2009.
The Equipment Under Test (EUT) was set up on a non-conductive table in the anechoic
chamber.
The radiated emissions measurements were made in a typical installation configuration.
The measurement procedure is implemented into the EMI test software ES-K1 from R&S.
The Loop antenna HFH2-Z2 is used.

-   Anechoic chamber
-   Antenna distance: 10 m
-   Detector: Peak-Maxhold
-   Frequency range 13.06 – 14.06 MHz
-   Frequency steps: 5 kHz
-   IF–Bandwidth: 10 kHz
-   Measuring time / Frequency step: 100 ms


3.3.2 Test Limits
FCC Part 15, Subpart C, §15.225 (a-d), and §15.209, corrected by the means of the
extrapolation of §15.31 due to the reduced measuring distance from 30m to 10m


3.3.3 Test Protocol

Temperature:       27 °C
Air Pressure:      1006 hPa
Humidity:          40 %

Op. Mode           Setup                     Port
op-mode 1          Setup_01                  Enclosure

      Maximum value                    Limit                    Remarks
         dBµV/m                       dBµV/m
           53.3                         93.5             measuring distance 10 m

Remark: Please see annex for the measurement plot.




3.3.4 Test result: Spectrum mask
                FCC Part 15, Subpart C    Op. Mode        Result
                                          op-mode 1       passed




Test report Reference: MDE_NXP_1201_FCCd                                           Page 14 of 32


3.4 Frequency tolerance

Standard       FCC Part 15, 10-1-11 Edition Subpart C

The test was performed according to: FCC §15.225


3.4.1 Test Description

The Equipment Under Test (EUT) is placed in a climatic temperature chamber.
The frequency drift during temperature and voltage variation is measured by the means
of a spectrum analyzer with frequency counter function.
The temperature was varied from –20 °C to +50 °C. At +20 °C the extreme power
supply voltages of 85% and 115% are applied. After reaching each target temperature
and waiting sufficient time allowing the temperature to stabilize, one measurement is
performed immediately after powering on the EUT, and two further measurements are
performed after 5 and 10 minutes continuous operation of EUT.


3.4.2 Test Limits
FCC Part 15, Subpart C, §15.225 (e): The frequency tolerance of the carrier signal shall
be maintained within ±0.01% of the operating frequency over a temperature variation of
-20 degrees to +50 degrees C at normal supply voltage, and for a variation in the
primary supply voltage from 85% to 115% of the rated supply voltage at a temperature
of 20 degrees C.




Test report Reference: MDE_NXP_1201_FCCd                                     Page 15 of 32


3.4.3 Test Protocol

 Temperature:       26 °C
 Air Pressure:      1010 hPa
 Humidity:          40 %

 Op. Mode          Setup                       Port
 op-mode 1         Setup_01                    Enclosure

   Temperature         Voltage        Time                Frequency            Delta
      / °C               /V          / min.                 / MHz              / Hz
        50              4.80            0                 13.559610            -390
        50              4.80            5                 13.559620            -380
        50              4.80           10                 13.559610            -390
        40              4.80            0                 13.559610            -390
        40              4.80            5                 13.559610            -390
        40              4.80           10                 13.559610            -390
        30              4.80            0                 13.559620            -380
        30              4.80            5                 13.559610            -390
        30              4.80           10                 13.559610            -390
        20              4.80            0                 13.559630            -370
        20              4.80            5                 13.559640            -360
        20              4.80           10                 13.559630            -370
        20              3.40            0                 13.559630            -370
        20              3.40            5                 13.559630            -370
        20              3.40           10                 13.559620            -380
        20              4.80            0                 13.559640            -360
        20              4.80            5                 13.559630            -370
        20              4.80           10                 13.559620            -380
        10              4.80            0                 13.559680            -320
        10              4.80            5                 13.559650            -350
        10              4.80           10                 13.559650            -350
        0               4.80            0                 13.559690            -310
        0               4.80            5                 13.559670            -330
        0               4.80           10                 13.559670            -330
       -10              4.80            0                 13.559690            -310
       -10              4.80            5                 13.559690            -310
       -10              4.80           10                 13.559690            -310
       -20              4.80            0                 13.559670            -330
       -20              4.80            5                 13.559690            -310
       -20              4.80           10                 13.559690            -310

Remark: The limit is a delta of max. ±1356 Hz (0.01 %).




3.4.4 Test result: Frequency tolerance
                FCC Part 15, Subpart C     Op. Mode                   Result
                                           op-mode 1                  passed




Test report Reference: MDE_NXP_1201_FCCd                                               Page 16 of 32


4      Test Equipment


    The calibration, hardware and software states are shown for the testing period.


    Test Equipment Anechoic Chamber
     Lab ID:                    Lab 3
     Manufacturer:              Frankonia
     Description:               Anechoic Chamber for radiated testing
     Type:                      10.58x6.38x6.00 m³

     Single Devices for Anechoic Chamber
       Single Device Name       Type                                     Serial Number     Manufacturer

       Air compressor           none                                     -                 Atlas Copco

       Anechoic Chamber         10.58 x 6.38 x 6.00 m³                   none              Frankonia
                                FCC listing 96716 3m Part15/18                             2011/01/11       2014/01/10
                                IC listing 3699A-1 3m                                      2011/02/07       2014/02/06

       Controller Innco 2000    CO 2000                                  CO2000/328/12470 Innco innovative constructions
                                                                         406/L            GmbH

       Controller Maturo        MCU                                      961208            Maturo GmbH

       EMC camera               CE-CAM/1                                 -                 CE-SYS

       EMC camera Nr.2          CCD-400E                                 0005033           Mitsubishi

       Filter ISDN              B84312-C110-E1                                             Siemens&Matsushita

       Filter Universal 1A      BB4312-C30-H3                            -                 Siemens&Matsushita


    Test Equipment Auxiliary Equipment for Conducted emissions
     Lab ID:                    Lab 1
     Manufacturer:              Rohde & Schwarz GmbH & Co.KG
     Description:               EMI Conducted Auxiliary Equipment

     Single Devices for Auxiliary Equipment for Conducted emissions
       Single Device Name       Type                                     Serial Number     Manufacturer

       AC Power Source          Chroma 6404                              64040001304       Chroma ATE INC.

       Cable "LISN to ESI"      RG214                                    W18.03+W48.03     Huber&Suhner
                                Path Calibration                                           2011/11/11   2012/11/10

       Coupling-Decoupling-     CDN ENY41                                100002            Rohde & Schwarz GmbH & Co.
       Network                                                                             KG
                                Standard calibration                                       2011/01/20   2013/01/19

       One-Line V-Network       ESH 3-Z6                                 100489            Rohde & Schwarz GmbH & Co.
                                                                                           KG
                                Standard calibration                                       2011/02/08   2014/02/07

       Two-Line V-Network       ESH 3-Z5                                 828304/029        Rohde & Schwarz GmbH & Co.
                                                                                           KG

       Two-Line V-Network       ESH 3-Z5                                 829996/002        Rohde & Schwarz GmbH & Co.
                                                                                           KG
                                DKD calibration                                            2011/01/20   2013/01/19




Test report Reference: MDE_NXP_1201_FCCd                                                                Page 17 of 32


   Test Equipment Auxiliary Equipment for Radiated emissions
    Lab ID:                 Lab 3
    Description:            Equipment for emission measurements
    Serial Number:          see single devices

    Single Devices for Auxiliary Equipment for Radiated emissions
      Single Device Name    Type                                  Serial Number    Manufacturer

      Antenna mast          AS 620 P                              620/37           HD GmbH

      Biconical dipole      VUBA 9117                             9117-108         Schwarzbeck
                            Standard Calibration                                   2008/10/27      2013/10/26
                            Standard Calibration                                   2012/01/18      2015/01/17

      Broadband Amplifier   JS4-18002600-32-5P                    849785           Miteq
      18MHz-26GHz

      Broadband Amplifier   AFS4-01000400-1Q-10P-4                -                Miteq
      1GHz-4GHz

      Broadband Amplifier   JS4-00101800-35-5P                    896037           Miteq
      30MHz-18GHz

      Cable "ESI to EMI     EcoFlex10                             W18.01-2+W38.01- Kabel Kusch
      Antenna"                                                    2

      Cable "ESI to Horn    UFB311A+UFB293C                       W18.02-2+W38.02- Rosenberger Micro-Coax
      Antenna"                                                    2

      Double-ridged horn    HF 906                                357357/001       Rohde & Schwarz GmbH & Co.
                                                                                   KG
                            Standard Calibration                                   2012/05/18   2015/05/17

      Double-ridged horn    HF 906                                357357/002       Rohde & Schwarz GmbH & Co.
                                                                                   KG

      Dreheinheit           DE 325                                                 HD GmbH

      High Pass Filter      4HC1600/12750-1.5-KK                  9942011          Trilithic

      High Pass Filter      5HC2700/12750-1.5-KK                  9942012          Trilithic

      High Pass Filter      5HC3500/12750-1.2-KK                  200035008        Trilithic

      High Pass Filter      WHKX 7.0/18G-8SS                      09               Wainwright

      Log.-per. Antenna     HL 562 Ultralog                       830547/003       Rohde & Schwarz GmbH & Co.
                                                                                   KG

      Loop Antenna          HFH2-Z2                               829324/006       Rohde & Schwarz GmbH & Co.
                                                                                   KG
                            Standard calibration                                   2011/10/27   2014/10/26

      Pyramidal Horn Antenna 3160-09                              00083069         EMCO Elektronik GmbH
      26,5 GHz

      Pyramidal Horn Antenna 3160-10                              00086675         EMCO Elektronik GmbH
      40 GHz

      Tilt device Maturo    Antrieb TD1.5-10kg                    TD1.5-           Maturo GmbH
      (Rohacell)                                                  10kg/024/3790709




Test report Reference: MDE_NXP_1201_FCCd                                                       Page 18 of 32


   Test Equipment Auxiliary Test Equipment
    Lab ID:                    Lab 3, Lab 4
    Manufacturer:              see single devices
    Description:               Single Devices for various Test Equipment
    Type:                      various
    Serial Number:             none

    Single Devices for Auxiliary Test Equipment
      Single Device Name       Type                                    Serial Number   Manufacturer

      AC Power Source          Chroma 6404                             64040001304     Chroma ATE INC.

      Broadband Power Divider 1506A / 93459                            LM390           Weinschel Associates
      N (Aux)

      Broadband Power Divider WA1515                                   A855            Weinschel Associates
      SMA

      Broadband Power Divider 1515 / 93459                             LN673           Weinschel Associates
      SMA (Aux)

      Digital Multimeter 01    Voltcraft M-3860M                       IJ096055        Conrad Electronics
      (Multimeter)

      Digital Multimeter 03    Fluke 177                               86670383        Fluke Europe B.V.
      (Multimeter)
                               Customized calibration                                  2011/10/19     2013/10/18

      Digital Oscilloscope     TDS 784C                                B021311         Tektronix GmbH
      [SA2] (Aux)

      Fibre optic link Satellite FO RS232 Link                         181-018         Pontis
      (Aux)

      Fibre optic link         FO RS232 Link                           182-018         Pontis
      Transceiver (Aux)

      Isolating Transformer    LTS 604                                 1888            Thalheimer
                                                                                       Transformatorenwerke GmbH


      Notch Filter Ultra Stable WRCA800/960-6EEK                       24              Wainwright
      (Aux)

      Spectrum Analyser        FSP3                                    836722/011      Rohde & Schwarz GmbH & Co.
                                                                                       KG

      ThermoHygro_01 (Aux) 430202                                      none            Fischer Feingerätebau K.
                                                                                       Fischer GmbH

      Vector Signal Generator SMIQ 03B                                 832492/061      Rohde & Schwarz GmbH &
                                                                                       Co.KG




Test report Reference: MDE_NXP_1201_FCCd                                                         Page 19 of 32


   Test Equipment Digital Signalling Devices
    Lab ID:                    Lab 1, Lab 3, Lab 4
    Description:               Signalling equipment for various wireless technologies.

    Single Devices for Digital Signalling Devices
      Single Device Name       Type                                     Serial Number    Manufacturer

      Bluetooth Signalling Unit CBT                                     100589           Rohde & Schwarz GmbH & Co.
      CBT                                                                                KG
                                Standard calibration                                     2011/11/24   2014/11/23

      CMW500                   CMW500                                   107500           Rohde & Schwarz GmbH &
                                                                                         Co.KG
                               Calibration Details                                       Last Execution Next Exec.
                               Initial factory calibration                               2012/01/26     2014/01/25
                               Firmware: V.2.01.25                                       2012/05/07     2012/07/03
                               3G :            KC42x 11.48.02
                               LTE:           KC501 1.6.5 up to 1.9.8
                                         KC503 1.6.5 up to 1.9.8
                                         KC506 1.9.8
                                         KC507 1.7.0
                                         KC508 1.8.5 up to 1.9.8
                                         KC551 1.4.1 up to 1.9.8
                                         KC553 1.5.5 up to 1.9.8
                                         KC571 1.8.5 up to 1.9.8
                                         KC572 1.8.5 up to 1.9.8
                               ---

      Digital Radio            CMD 55                                   831050/020       Rohde & Schwarz GmbH & Co.
      Communication Tester                                                               KG
                               Standard calibration                                      2011/11/28   2014/11/27

      Digital Radio Test Set   6103E                                    2359             Racal Instruments, Ltd.

      Universal Radio          CMU 200                                  102366           Rohde & Schwarz GmbH & Co.
      Communication Tester                                                               KG
                               Standard calibration                                      2011/05/26    2013/05/25
                               HW/SW Status                                              Date of Start  Date of End
                               Hardware:                                                 2007/07/16
                               B11, B21V14, B21-2, B41, B52V14, B52-2,
                               B53-2, B56V14, B68 3v04, PCMCIA, U65V04
                               Software:
                               K21 4v21, K22 4v21, K23 4v21, K24 4v21, K42     4v21,
                               K43 4v21, K53 4v21, K56 4v22, K57 4v22, K58     4v22,
                               K59 4v22, K61 4v22, K62 4v22, K63 4v22, K64     4v22,
                               K65 4v22, K66 4v22, K67 4v22, K68 4v22, K69     4v22
                               Firmware:
                               µP1 8v50 02.05.06
                               ---

      Universal Radio          CMU 200                                  837983/052       Rohde & Schwarz GmbH & Co.
      Communication Tester                                                               KG
                               Standard calibration                                      2011/12/07    2014/12/06
                               HW/SW Status                                              Date of Start  Date of End
                               HW options:                                               2007/01/02
                               B11, B21V14, B21-2, B41, B52V14, B52-2,    B53-2,
                               B54V14, B56V14, B68 3v04, B95, PCMCIA,     U65V02
                               SW options:
                               K21 4v11, K22 4v11, K23 4v11, K24 4v11,    K27 4v10,
                               K28 4v10, K42 4v11, K43 4v11, K53 4v10,    K65 4v10,
                               K66 4v10, K68 4v10,
                               Firmware:
                               µP1 8v40 01.12.05
                               ---
                               SW:                                                       2008/11/03
                               K62, K69

      Vector Signal Generator SMU200A                                   100912           Rohde & Schwarz GmbH & Co.
                                                                                         KG

Test report Reference: MDE_NXP_1201_FCCd                                                           Page 20 of 32


   Test Equipment Emission measurement devices
    Lab ID:                   Lab 1, Lab 3
    Description:              Equipment for emission measurements
    Serial Number:            see single devices

    Single Devices for Emission measurement devices
      Single Device Name      Type                                   Serial Number   Manufacturer

      Personal Computer       Dell                                   30304832059     Dell

      Power Meter             NRVD                                   828110/016      Rohde & Schwarz GmbH &
                                                                                     Co.KG
                              Standard calibration                                   2012/05/22   2013/05/21

      Power Sensor            NRV-Z1                                 836219/005      Rohde & Schwarz GmbH & Co.
                                                                                     KG

      Powermeter              NRVS                                   836333/064      Rohde & Schwarz GmbH & Co.
                                                                                     KG

      Sensor Head A           NRV-Z1                                 827753/005      Rohde & Schwarz GmbH &
                                                                                     Co.KG
                              Standard calibration                                   2012/05/21   2013/05/20

      Signal Generator        SMR 20                                 846834/008      Rohde & Schwarz GmbH & Co.
                                                                                     KG
                              standard calibration                                   2011/05/12   2014/05/11

      Spectrum Analyzer       ESIB 26                                830482/004      Rohde & Schwarz GmbH & Co.
                                                                                     KG
                              Standard Calibration                                   2011/12/05    2013/12/04
                              HW/SW Status                                           Date of Start  Date of End
                              Firmware-Update 4.34.4 from 3.45 during calibration    2009/12/03



   Test Equipment Multimeter 12
    Lab ID:                   Lab 5, Lab 6
    Description:              Ex-Tech 520
    Serial Number:            05157876

    Single Devices for Multimeter 12
      Single Device Name      Type                                   Serial Number   Manufacturer

      Digital Multimeter 12   EX520                                  05157876        Extech Instruments Corp.
      (Multimeter)
                              Customized calibration                                 2011/10/18     2013/10/17




Test report Reference: MDE_NXP_1201_FCCd                                                      Page 21 of 32


   Test Equipment Radio Lab Test Equipment
    Lab ID:                  Lab 4
    Description:             Radio Lab Test Equipment

    Single Devices for Radio Lab Test Equipment
      Single Device Name     Type                       Serial Number    Manufacturer

      Broadband Power Divider WA1515                    A856             Weinschel Associates
      SMA

      Coax Attenuator 10dB   4T-10                      F9401            Weinschel Associates
      SMA 2W

      Coax Attenuator 10dB   56-10                      W3702            Weinschel Associates
      SMA 2W

      Coax Attenuator 10dB   56-10                      W3711            Weinschel Associates
      SMA 2W

      Coax Cable             Sucotest 2,0m                               Rosenberger Micro-Coax
      Huber&Suhner

      Coax Cable Rosenberger FA210A0010003030           54491-2          Rosenberger Micro-Coax
      Micro Coax
      FA210A0010003030
      SMA/SMA 1,0m


      Power Meter            NRVD                       828110/016       Rohde & Schwarz GmbH &
                                                                         Co.KG
                             Standard calibration                        2012/05/22   2013/05/21

      Power Sensor           NRV-Z1                     836219/005       Rohde & Schwarz GmbH & Co.
                                                                         KG

      Powermeter             NRVS                       836333/064       Rohde & Schwarz GmbH & Co.
                                                                         KG

      RF Step Attenuator RSP RSP                        833695/001       Rohde & Schwarz GmbH &
                                                                         Co.KG

      Rubidium Frequency     Datum, Model: MFL          2689/001         Datum-Beverly
      Standard
                             Standard calibration                        2011/06/17      2012/06/16

      Sensor Head A          NRV-Z1                     827753/005       Rohde & Schwarz GmbH &
                                                                         Co.KG
                             Standard calibration                        2012/05/21   2013/05/20

      Signal Generator       SMY02                      829309/018       Rohde & Schwarz GmbH & Co.
                                                                         KG
                             Standard calibration                        2011/11/04   2014/11/03

      Signal Generator SME   SME03                      827460/016       Rohde & Schwarz GmbH &
                                                                         Co.KG
                             Standard calibration                        2011/11/25   2014/11/24

      Signal Generator SMP   SMP02                      836402/008       Rohde & Schwarz GmbH & Co.
                                                                         KG

      Spectrum Analyser      FSIQ26                     840061/005       Rohde & Schwarz GmbH & Co.
                                                                         KG
                             Standard calibration                        2011/02/10   2013/02/09

      Temperature Chamber    VT 4002                    58566002150010   Vötsch
      Vötsch 03
                             Customized calibration                      2012/03/12      2014/03/11

      Vector Signal Generator SMIQ 03B                  837747/020       Rohde & Schwarz GmbH & Co.
                                                                         KG




Test report Reference: MDE_NXP_1201_FCCd                                          Page 22 of 32


   Test Equipment Regulatory Bluetooth RF Test Solution
    Lab ID:                    Lab 5
    Description:               Regulatory Bluetooth RF Tests
    Type:                      Bluetooth RF
    Serial Number:             001

    Single Devices for Regulatory Bluetooth RF Test Solution
      Single Device Name       Type                                  Serial Number   Manufacturer

      ADU 200 Relay Box 7      Relay Box                             A04380          Ontrak Control Systems Inc.

      Bluetooth Signalling Unit CBT                                  100302          Rohde & Schwarz GmbH &
      CBT                                                                            Co.KG
                                Standard Calibration                                 2011/08/17   2012/08/16

      Power Meter NRVD         NRVD                                  832025/059
                               Standard Calibration                                  2011/06/14     2012/06/13

      Power Sensor NRV Z1 A PROBE                                    832279/013

                               Standard Calibration                                  2011/06/14     2012/06/13

      Power Supply             NGSM 32/10                            2725
                               Standard Calibration                                  2011/06/15     2013/06/14

      Rubidium Frequency       Datum MFS                             002             Datum GmbH
      Normal MFS
                               Standard Calibration                                  2011/08/17     2012/08/16

      Signal Analyser FSIQ26 1119.6001.26                            832695/007      Rohde & Schwarz GmbH &
                                                                                     Co.KG

      Signal Generator         SMP03                                 833680/003      Rohde & Schwarz GmbH &
                                                                                     Co.KG
                               Standard Calibration                                  2009/06/23   2012/06/22

      Vector Signal Generator SMIQ03B                                832870/017
      SMIQ03B
                              Standard Calibration                                   2010/06/23     2013/06/20


   Test Equipment Shielded Room 02
    Lab ID:                    Lab 1
    Manufacturer:              Frankonia
    Description:               Shielded Room for conducted testing
    Type:                      12 qm
    Serial Number:             none


   Test Equipment Shielded Room 07
    Lab ID:                    Lab 5, Lab 6
    Description:               Shielded Room 4m x 6m


   Test Equipment T/H Logger 04
    Lab ID:                    Lab 5, Lab 6
    Description:               Lufft Opus10
    Serial Number:             7481

    Single Devices for T/H Logger 04
      Single Device Name       Type                                  Serial Number   Manufacturer

      ThermoHygro Datalogger Opus10 THI (8152.00)                    7481            Lufft Mess- und Regeltechnik
      04 (Environ)                                                                   GmbH




Test report Reference: MDE_NXP_1201_FCCd                                                       Page 23 of 32


   Test Equipment Temperature Chamber 01
    Lab ID:                   Lab 5, Lab 6
    Manufacturer:             see single devices
    Description:              Temperature Chamber KWP 120/70
    Type:                     Weiss
    Serial Number:            see single devices

    Single Devices for Temperature Chamber 01
      Single Device Name      Type                                 Serial Number    Manufacturer

      Temperature Chamber     KWP 120/70                           59226012190010   Weiss Umwelttechnik GmbH
      Weiss 01
                              Customized calibration                                2012/03/12       2014/03/11


   Test Equipment WLAN RF Test Solution
    Lab ID:                   Lab 6
    Manufacturer:             7 layers AG
    Description:              Regulatory WLAN RF Tests
    Type:                     WLAN RF
    Serial Number:            001

    Single Devices for WLAN RF Test Solution
      Single Device Name      Type                                 Serial Number    Manufacturer

      Arbitrary Waveform      TGA12101                             284482
      Generator

      Power Meter NRVD        NRVD                                 832025/059
                              Standard Calibration                                  2011/06/14       2012/06/13

      Power Sensor NRV Z1 A PROBE                                  832279/013

                              Standard Calibration                                  2011/06/14       2012/06/13

      Power Supply            NGSM 32/10                           2725
                              Standard Calibration                                  2011/06/15       2013/06/14

      Rubidium Frequency      Datum MFS                            002              Datum GmbH
      Normal MFS
                              Standard Calibration                                  2011/08/17       2012/08/16

      Signal Analyser FSIQ26 1119.6001.26                          832695/007       Rohde & Schwarz GmbH &
                                                                                    Co.KG

      Signal Generator        SMP03                                833680/003       Rohde & Schwarz GmbH &
                                                                                    Co.KG
                              Standard Calibration                                  2009/06/23   2012/06/22

      Spectrum Analyser       FSU26                                100136           Rohde & Schwarz GmbH &
                                                                                    Co.KG
                              FSU FW Update to v4.61 SP3, K5 v4.60 and K73 v4.61    2011/12/05

      Spectrum Analyser       FSU3                                 200046           Rohde & Schwarz GmbH &
                                                                                    Co.KG
                              Standard calibration                                  2012/05/15   2013/05/14
                              Firmware Version 4.51 SP1                             2011/12/07
                              Option FS-K72 4.50 SP1
                              Option FS-K73 4.50 SP1

      TOCT Switching Unit     Switching Unit                       030106           7 layers, Inc.

      TOCT Switching Unit     Switching Unit                       030101           7 layers, Inc.
      (loan unit)

      Vector Signal Generator SMIQ03B                              832870/017
      SMIQ03B
                              Standard Calibration                                  2010/06/23       2013/06/20


Test report Reference: MDE_NXP_1201_FCCd                                                       Page 24 of 32


5     Photo Report

Photos are included in an external report.




6     Setup Drawings




Drawing 1:     Setup in the Anechoic chamber:
               Measurements below 1 GHz: Semi-anechoic, conducting ground plane.




Test report Reference: MDE_NXP_1201_FCCd                                  Page 25 of 32


7     FCC and IC Correlation of measurement
      requirements

The following tables show the correlation of measurement requirements for RFID
equipment and Digital Apparatus from FCC and IC standards.


RFID equipment

Measurement                      FCC reference          IC reference
Conducted emissions on AC        § 15.207               RSS-Gen: 7.2.4
mains
Spurious radiated emissions      § 15.209               RSS-Gen: 6;
                                                        RSS-210: A2.6
Occupied bandwidth               § 15.215               RSS-Gen: 4.6
Spectrum Mask                    § 15.225               RSS-210: A2.6
Frequency Tolerance              § 15.225               RSS-210: A2.6


Digital Apparatus

Measurement                      FCC reference          IC reference
Conducted Emissions              § 15.107               ICES-003
(AC Power Line)
Spurious Radiated Emissions      § 15.109               ICES-003




Test report Reference: MDE_NXP_1201_FCCd                                   Page 26 of 32


8          Annex measurement plots

8.1 Radiated emissions

8.1.1 Radiated emissions (f < 30 MHz)

Antenna position 90°
EUT position vertical

 Marker:                      13.56 MHz                           53.32 dBµV/m                  X

       Level [dBµV/m]
 110

 100




    80




    60




    40




    20

    10
            9k          20k    40k        100k            300k                   1M   2M   4M       10M        30M
                                                 Frequency [Hz]

           MES NXP_1201_006_pre PK
           LIM H-Field_FCC_RFID




Antenna position 90°
EUT position horizontal

 Marker:                      13.56 MHz                           47.78 dBµV/m                  X

       Level [dBµV/m]
 110

 100




    80




    60




    40




    20

    10
            9k          20k    40k        100k            300k                   1M   2M   4M       10M       30M
                                                 Frequency [Hz]

           MES NXP_1201_005_pre PK
           LIM H-Field_FCC_RFID




Test report Reference: MDE_NXP_1201_FCCd                                                              Page 27 of 32


Antenna position 0°
EUT position vertical

 Marker:                      13.56 MHz                           47.01 dBµV/m                  X

       Level [dBµV/m]
 110

 100




   80




   60




   40




   20

   10
            9k          20k   40k         100k           300k                    1M   2M   4M       10M        30M
                                                 Frequency [Hz]

          MES NXP_1201_007_pre PK
          LIM H-Field_FCC_RFID




Antenna position 0°
EUT position horizontal

 Marker:                      13.56 MHz                           41.84 dBµV/m                  X

       Level [dBµV/m]
 110

 100




   80




   60




   40




   20

   10
            9k          20k   40k         100k           300k                    1M   2M   4M       10M       30M
                                                 Frequency [Hz]

          MES NXP_1201_004_pre PK
          LIM H-Field_FCC_RFID




Test report Reference: MDE_NXP_1201_FCCd                                                              Page 28 of 32


8.1.2 Radiated emissions (f > 30 MHz)


    Level [dBµV/m]
 80


 70


 60


 50
                                                                               x
                                                                                   x     x
 40                                                                 x


 30           x
                                                         x

 20               x


 10
                               x                     x       x

    0
        30M           50M    70M       100M                  200M       300M           500M   700M     1G
                                          Frequency [Hz]

x       MES NXP_1201_002_fin QP
        MES NXP_1201_002_pre PK
        LIM FCC part 15 b  Field Strength QP Limit




Test report Reference: MDE_NXP_1201_FCCd                                                      Page 29 of 32


8.2 Occupied bandwidth

                          Delta 1 [T1]                RBW     10 kHz     RF Att     10 dB
        Ref Lvl                     -22.64 dB         VBW     10 kHz
        53 dBÌ A             -144.28857715 kHz        SWT     50 ms      Unit          dBÌ A
   53
   50                                                           1 [T1]          31.35 dBÌ A
                                                                                                A
                                                                         13.56200401 MHz
                                                                1 [T1]          -22.64 dB
   40
                                                                       -144.28857715 kHz
                                                  1             2 [T1]          -21.37 dB
         D1 31.35 dBÌ A
   30                                                                    144.28857715 kHz



   20 1VIEW                                                                                    1MA


                                                          2
            D2 11.35 dBÌ A                 1
   10
                                                                                               EXT


    0



  -10



  -20



  -30



  -40


  -47
        Center 13.56 MHz                       200 kHz/                         Span 2 MHz

Title:     20dB Bandwidth
Comment A: CS020g01
Date:      26.JUL.2012 12:50:46




Test report Reference: MDE_NXP_1201_FCCd                                            Page 30 of 32


                          Marker 1 [T1]               RBW        10 kHz      RF Att      10 dB
        Ref Lvl                     31.35 dBÌ A       VBW        10 kHz
        53 dBÌ A              13.56200401 MHz         SWT        50 ms       Unit          dBÌ A
   53
   50                                                              1 [T1]           31.35 dBÌ A
                                                                                                   A
                                                                             13.56200401 MHz
                                                                  OPB       501.00200401 kHz
   40
                                                                   T1 [T1]          -0.72 dBÌ A
                                                  1                          13.28144289 MHz
         D1 31.35 dBÌ A
   30                                                              T2 [T1]            7.47 dBÌ A
                                                                             13.78244489 MHz

   20 1VIEW                                                                                        1MA


            D2 11.35 dBÌ A
   10                                                       T2
                                                                                                   EXT

                                    T1
    0



  -10



  -20



  -30



  -40


  -47
        Center 13.56 MHz                   200 kHz/                                 Span 2 MHz

Title:     99 Bandwidth
Comment A: CS020g01
Date:      26.JUL.2012 12:58:18




Test report Reference: MDE_NXP_1201_FCCd                                                     Page 31 of 32


8.3 Spectrum mask

 Marker:                13.56 MHz                      53.32 dBµV/m           X

   Level [dBµV/m]
 110

 100




   80




   60




   40




   20

   10
        13M           13.2M         13.4M                    13.6M    13.8M       14.1M
                                      Frequency [Hz]

        MES NXP_1201_006_pre PK
        LIM H-Field_FCC_RFID




Test report Reference: MDE_NXP_1201_FCCd                                             Page 32 of 32



Document Created: 2012-07-27 15:32:37
Document Modified: 2012-07-27 15:32:37

© 2024 FCC.report