Test Setup Photos M16.pdf

FCC ID: XXMJN5189M16

Test Setup Photos

Download: PDF

10.     AC Power Line Conpuctep Emissions

10.1.   TEST CONDITIONS

Test performed by              : Willy DACLINAT
Date of test                   : April 19, 2018
Ambient temperature            126 °C
Relative humidity              145 %

10.2.   TEST SETUP

The product has been tested according to ANSI C63.10 (2013) method. The EUT is placed on the ground reference
plane, at 8Ocm from the LISN. The distance between the EUT and the vertical ground plane is 40cm, Auxiliaries are
powered by another LISN. The cable has been shorted to 1meter length. The EUT is powered through the LISN.
Measurementis made with a receiver in peak mode. This was followed by a Quasi—Peak, e. CISPR measurement for
any strong signal. If the average limit is met when using a Quasi—Peak detector, the EUT shall be deemed to mest both
limits and measurement with the average detector is unnecessary. The LISN (measure) is 500 / 50uH. Interconnecting
cables and equipment‘s were moved to position that maximized emission.




Photograph for AC Power Line Conducted Emissions (Front view)




                                                   TEST REPORT
N° 154772—719318                                    Version : 01                                          Page 3052


Photograph for AC Power Line Conducted Emissions (Rear view)

10.1.    LIMIT

Quasi—Peak
0,15kHz to 0,5MHz: 66dBuV to 56dBuV*
0,5MHz to 5SMHz: 56dBuV
SMHz to 30MHz: 60dBuV

Average
0,15kHz to 0,5MHz: 56dBuV to 46dBuV*
0,5MHz to SMHz: 46dBuV
SMHz to 30MHz: 50dBuV

*Decreases with the logarithm of the frequency


10.2.     TEST EQUIPMENT LIST

           DESCRIPTION           MANUFACTURER               MODEL              N° LCIE      Cal_Date       Cal_Due
             EM Recaiver         ROHDE & SCHWARZ              ESUZ6            A2642018      2016710       2018710
                 RSIL            ROHDE & SCHWARZ             ENV215            c2s20162      201801        201901
                 Cable                    —                                    A5s20414      20176         201806
                 Note: In our quality system, the test equipment calibration due is more & less 2 months

10.3.    DIVERGENCE, ADDITION OR SUPPRESSION ON THE TEST SPECIFICATION

& None           C Divergence:




                                                     TEST REPORT
N° 154772—719318                                      Version : 01                                             Page 31/52


11.     UnwanTED Emissions in RestRIctED FREQUENCY BanDs

11.1.   TEST CONDITIONS

Test performed by             : Armand MAHOUNGOU
Date of test                  : April 16, 2018
Ambient temperature           126 °C
Relative humidity             145 %

11.2.   TEST SETUP

The product has been tested according to ANSI C63.10 (2013). The EUT is placed ina semi—anechoic chamber.
Distance between measuring antenna and the EUT is 3m. Test is performed in horizontal (H) and vertical (V)
polerization with bileg antenna below 1GHz and with a hom antenna above 1GHz. Measurement bandwidth was
120kHz below 1GHz and 1MHz above 1GHz. The level has been maximised by the turntable rotation of 360 degrees
range on the 3 axis of EUT. Antenna height search was performed from 1 to 4m. The EUT is place at 1.5m high above
1GHz and at 0.8m high under 1GHz.




Photograph for Unwanted Emission in restricted frequency bands




                                                  TEST REPORT
N° 154772—719318                                   Version : 01                                       Page 3652


Photograph for Unwanted Emission in restricted frequecy bands




                                                 TEST REPORT
N° 15§4772—719318                                 Version : 01   Page 37/52


                    TEST REPORT
N° 15§4772—719318    Version : 01   Page 38/52



Document Created: 2019-04-03 10:02:37
Document Modified: 2019-04-03 10:02:37

© 2019 FCC.report
This site is not affiliated with or endorsed by the FCC