                                                               Page 1 of 15                          Report No.: OT-196-RWD-001




                            ELECTROMAGNETIC EMISSION
                               COMPLIANCE REPORT
         Test Report No.                 : OT-196-RWD-001

         AGR No.                         : A194A-151R

         Applicant                       : UNION COMMUNITY
        Address                          : Hyundai Topics Bldg. Bangi 2-dong, Songpa-gu, Seoul, South Korea

         Manufacturer                    : UNION COMMUNITY
        Address                          : Hyundai Topics Bldg. Bangi 2-dong, Songpa-gu, Seoul, South Korea

         Type of Equipment               : Access controller

         FCC ID                          : XX2-UBIO-XSLIM-RF

         Model Name                      : UBio-X Slim RF

         Multiple Model Name             : N/A

         Serial number                   : N/A

         Total page of Report            : 15 pages (including this page)

         Date of Incoming                : May 10, 2019

         Date of Issuing                 : June 04, 2019



         SUMMARY
         The equipment complies with the requirements of
         FCC CFR 47 PART 15 Subpart C Section 15.209 and 15.207.
         This test report only contains the result of a single test of the sample supplied for the examination.
         It is not a generally valid assessment of the features of the respective products of the mass-production.




        Reviewed by:                                                            Approved by:
                            Tae-Ho, Kim / Senior Manager                                         Ki-Hong, Nam / Chief Engineer
                            ONETECH Corp.                                                        ONETECH Corp.



It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


oneETECH
        N#                                                            Page 2 of 15                                     Report No.: OT—196—RWD—001


                                                                     CONTENTS
                                                                                                                                                                Page


1. VERIFICATION OF COMPLIANCE                                                                                                                                         4


2. GENERAL INFORMATION                                                                                                                                                5

  2.1 PRODUCT DESCRIPTION::. 2220000000000 00000000 n000 00e en n n n en n narenne n n en nnenennennennenarennenne en en nnennennennennennennnnennnnnnenennenne 5
  2.2 MODEL DIFFERENCES! a2.00.00.0000000000000 00e en rerennennnnenne n en n narennenne n en nnenennennennennrennennennennennnnnnennnnennennnnennnnnnennnenne 5

  2.3 RELATED SUBMITTAL(S) / GRANT(S) .. 22.00.0020.000.0000000000000000n0en0emernnnne en nnenennennenne en narennenne en nne en en en en en narennennennennenennennea 5

  2.4 PURPOSE OF THE TEST ... 2000000000000 00e n en en n n nnenn en n en revnnennennenennennennennrennennennnnennnnennennennnennennnnennennnnenennenne 5

  2.5 TEST METHODOLOGY...
  2.6 TEST FACILITY....                                                                                                                                             ...6

3. SYSTEM TEST CONFIGURATION                                                                                                                                          7

   3. 1 JJUSTIFICATION 12200000000 0000000000 00e n en n n n n en en n nnenn n nnenne n nnenennennnnenn en nnnnnnnnnnennennnnnnennennnnennenennennenne 7

   3.2 PERIPHERAL EQUIPMENT ..2.22.22.00.0.00.00.000u00000000e00en0 en en en en nnenenennennennennenne ennenneannarennnnenneaneaneaneanannnnnenneaneaneanenennennenne 7

   3.3 MODE OF OPERATION DURING THE TEST .......0..00.00.00.0000000000en0 en en en nnennnennnnennenne en en en en en en en narenne en nnnnennnennennenne 7

   3.4 EQUIPMENT MODIFICATIONS ....2..2.00000e00e00e000e00e0 en en en en en neareneeneeneeneeneneeneeneeneeareeneeneeneeneeneeneeneeneenserseeneeneeneenenerneencene 7
   3.5 CONFIGURATION OF TEST SYSTEM .. 22.00.00.00000000000000 00e en0 en en en en en en en en en nnenn n en en en en en en en nnnnnnennnnennnennennenne 8

   3.6 ANTENNA REQUIREMENT ....                                                                                                                                     ...8


4. PRELIMINARY TEST                                                                                                                                                   8

   4.1 AC POWER LINE CONDUCTED EMISSIONS TESTS...... 2200000000000 00000000 n0 en eennmare en en en en en en en en nnrenne en en en nnenennennenne 8

   4.2 RADIATED EMISSIONS TESTS.. ... 2220000000000 0000 en en n nare n en en en en en en en narenne en en en en en en nnnnnnenn en en nnnennennenne 8

5. FINAL RESULT OF 132.5 KHZ MEASUREMENT                                                                                                                              9

   5.1 CONDUCTED EMISSION TEST...2.22.0. 0000000000000 00e en en nnenare n en en en en n en en narenne en en en en en nnnnnn en nn en en nnnennennenne 9

   5.2 RADIATED EMISSION TEST BELOW 30 MHZ........22.22.00n00n00e0e000n0eneeneenvenennennenvenvenneeneennennennennennennennenneencennennencencencnnencen 11
   5.3 RADIATED EMISSION TEST ABOVE 30 MHZ ........22.00.00.00.00000000000en0 en rnrvenenrenrennenrenr en en en en en en en narenne en nnennnnenennenne 12

   5.4 BANDWIDTH OF THE OPERATING FREQUENCY ....22.22.00.00.00.00 u0000000000000 n0e en ennennnarennenneanennennennennennenneennennennennennenennennea 13


6. FIELD STRENGTH CALCULATION                                                                                                                                        14


7. LIST OF TEST EQUIPMENT                                                                                                                                            15




Tt should not be reproduced except in full, withoutthe written approval of ONETECH Corp.                                                           EMC—003 (Rev.2)
ONETECH Corp.: 43—14, Jinsaegol—gil, Chowol—eup, Gwangiu—si, Gyeonggi—do, 12735, Korea (TEL: 82—31—799—9500, FAX: 82—31—799—9599)


                                                               Page 3 of 15                           Report No.: OT-196-RWD-001


                                                             Revision History
 Rev. No.          Issue Report No.                     Issued Date                           Revisions                 Section Affected
     0            OT-196-RWD-001                       June 04, 2019                        Initial Release                     All




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 4 of 15                          Report No.: OT-196-RWD-001


1. VERIFICATION OF COMPLIANCE
-. APPLICANT                   : UNION COMMUNITY
-. ADDRESS                     : Hyundai Topics Bldg. Bangi 2-dong, Songpa-gu, Seoul, South Korea
-. CONTACT PERSON              : KyungWook, Han
-. TELEPHONE NO                : +82-2-6488-3027
-. FCC ID                      : XX2-UBIO-XSLIM-RF
-. MODEL NO/NAME               : UBio-X Slim RF
-. SERIAL NUMBER               : N/A
-. DATE                        : June 04, 2019

 DEVICE TYPE                                               DCD – Part 15, Low Power Transmitter below 1 705 kHz
 E.U.T. DESCRIPTION                                        Access controller
 THIS REPORT CONCERNS                                      Original Grant
 MEASUREMENT PROCEDURES                                    ANSI C63.10: 2013
 TYPE OF EQUIPMENT TESTED                                  Pre-Production
 KIND OF EQUIPMENT
                                                           Certification
 AUTHORIZATION REQUESTED
 EQUIPMENT WILL BE OPERATED
                                                           FCC CFR47 Part 15 Subpart C Section 15.207 and 15.209
 UNDER FCC RULES PART(S)
 MODIFICATIONS ON THE EQUIPMENT
                                                           None
 TO ACHIEVE COMPLIANCE
 FINAL TEST WAS CONDUCTED ON                               3 m, Semi Anechoic Chamber

-. The above equipment was tested by ONETECH Corp. for compliance with the requirement set forth in the FCC Rules
   and Regulations. This said equipment in the configuration described in this report, shows the maximum emission levels
   emanating from equipment are within the compliance requirements.




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 5 of 15                          Report No.: OT-196-RWD-001


2. GENERAL INFORMATION


2.1 Product Description
The UNION COMMUNITY, Model UBio-X Slim RF (referred to as the EUT in this report) is an Access controller,
Product specification information described herein was obtained from product data sheet or user’s manual.

  DEVICE TYPE                                      Access controller
  TRANSMITTING FREQUENCY                           132.5 kHz, 2 402 MHz ~ 2 480 MHz
  MODULATION                                       ASK
  ANTENNA TYPE                                     Coil Antenna
  LIST OF EACH OSC.                                1.4 MHz, 1.5 MHz, 32.768 kHz, 24 MHz, 25 MHz, 7.327 28 MHz, 8 MHz,
  OR CRY. FREQ.(FREQ .>= 1 MHz)                    27.12 MHz, 1.4 GHz,
                                                   OUTPUT: DC 12 V, 3.5 A
  USED AC/DC ADAPTER                               Model No : DSA-42PFB-12 1 120350
                                                   Manufacturer : Dee Van Electronics(Longchuan)Co., Ltd


2.2 Model Differences:
-. None

2.3 Related Submittal(s) / Grant(s)
Original submittal only


2.4 Purpose of the test
To determine whether the equipment under test fulfills the requirements of the regulation stated in FCC PART 15
SUBPART C Section 15.209 and 15.207.

2.5 Test Methodology
Both conducted and radiated testing was performed according to the procedures in ANSI C63.10: 2013. Radiated testing
was performed at a distance of 3 m from EUT to the antenna.




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 6 of 15                          Report No.: OT-196-RWD-001

2.6 Test Facility
The Onetech Corp. has been designated to perform equipment testing in compliance with ISO/IEC 17025.
The Electromagnetic compatibility measurement facilities are located at 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si,
Gyeonggi-do, 12735, Korea
-. Site Filing:
VCCI (Voluntary Control Council for Interference) – Registration No. R-4112/ C-14617/ G-10666 / T-1842
IC (Industry Canada) – Registration No. Site# 3736A-3
-. Site Accreditation:
KOLAS (Korea Laboratory Accreditation Scheme) - Accreditation NO. KT085
FCC (Federal Communications Commission) - Accreditation No. KR0013
RRA (Radio Research Agency) – Designation No. KR0013




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 7 of 15                           Report No.: OT-196-RWD-001


3. SYSTEM TEST CONFIGURATION

3.1 Justification
 This device was configured for testing in a typical way as a normal customer is supposed to be used. During the test, the
 following components were installed inside of the EUT.

          DEVICE TYPE                                MANUFACTURER                           MODEL/PART NUMBER                  FCC ID

           MAIN BOARD                                          N/A                           PFXSMA01 V1.0 RSE20                    N/A

            SUB BOARD                                          N/A                           PFXSRF01 V1.0 RSE20                    N/A

     FINGERPRINT BOARD                                         N/A                          PFNSSESMA01 V10 RJL16                   N/A

            LED BOARD                                          N/A                           PFXSLD01 V10 RSE20                     N/A

              DISPLAY                                 KJC Display Corp                       FPC-RT050T101-G2 V1                    N/A

              SPEAKER                                          N/A                                   N/A                            N/A

       CAMERA MODULE                                           N/A                                   N/A                       N/A
                                                                                                                             2AEEY-
       Bluetooth LE Module                             PROCHILD INC.                             PBLN51822m                PBLN51822M
             ANTENNA                                        N/A                                      N/A                            N/A
                                                     Dee Van Electronics
              ADAPTER                               (Longchuan) Co., Ltd                     DSA-42PFB-12 1 120350                  N/A


3.2 Peripheral equipment
Defined as equipment needed for correct operation of the EUT, but not considered as tested:
              Model                                     Manufacturer                                Description              Connected to
        UBio-X Slim RF                             UNION COMMUNITY                             Access controller (EUT)                -
                                                     Dee Van Electronics
   DSA-42PFB-12 1 120350                            (Longchuan) Co., Ltd                             ADAPTER                        EUT

            Ideapad330                                     LENOVO                                   Notebook PC                     EUT
          PA-1450-55LR                           LITE-ON TECHNOLOGY                                  ADAPTER                          -
                N/A                                            N/A                                Door Open Switch                  EUT
                N/A                                            N/A                                   Door lock                      EUT
                N/A                                            N/A                                      Card                          -


3.3 Mode of operation during the test
-. The EUT has 132.5 kHz RF boards for reading Card and program was used for making continuous transmission mode
  during the test.


3.4 Equipment Modifications
-. None


It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 8 of 15                          Report No.: OT-196-RWD-001


3.5 Configuration of Test System
Line Conducted Test :                 The EUT was connected to adaptor and the power of adaptor was connected to LISN. All
                                      supporting equipments were connected to another LISN. Preliminary Power line Conducted
                                      Emission test was performed by using the procedure in ANSI C63.10: 2013 to determine
                                      the worse operating conditions.



Radiated Emission Test :              Preliminary radiated emissions test were conducted using the procedure in ANSI C63.10:
                                      2013 to determine the worse operating conditions. The radiated emissions measurements
                                      were performed on the 10 m Semi Anechoic Chamber.
                                      For frequencies from 150 kHz to 30 MHz measurements were made of the magnetic H field.
                                      The measuring antenna is an electrically screened loop antenna.
                                      The frequency spectrum from 30 MHz to 1 000 MHz was scanned and maximum emission
                                      levels maximized at each frequency recorded. The system was rotated 360°, and the antenna
                                      was varied in the height between 1.0 m and 4.0 m in order to determine the maximum
                                      emission levels. This procedure was performed for both horizontal and vertical polarization
                                      of the receiving antenna.


3.6 Antenna Requirement
For intentional device, according to section 15.203, an intentional radiator shall be designed to ensure that no antenna other
than that furnished by the responsible party shall be used with the device.

Antenna Construction:
The transmitter antenna of the EUT is a Coil Antenna and Chip Antenna so there is no consideration of replacement by the user.

4. PRELIMINARY TEST

4.1 AC Power line Conducted Emissions Tests
During Preliminary Tests, the following operating mode was investigated
                         Operation Mode                                    The Worse operating condition (Please check one only)

                        Transmitting Mode                                                               X


4.2 Radiated Emissions Tests
During Preliminary Tests, the following operating modes were investigated
                         Operation Mode                                    The Worse operating condition (Please check one only)

                        Transmitting Mode                                                               X




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 9 of 15                          Report No.: OT-196-RWD-001


5. FINAL RESULT OF 132.5 kHz MEASUREMENT
Preliminary test was done in normal operation mode. And the final measurement was selected for the maximized emission level.


5.1 Conducted Emission Test

Humidity Level           : (49 ~ 50) % R.H.                                                                   Temperature: (22 ~ 23) ºC

Limits apply to          : FCC CFR 47, PART 15, SUBPART B, SECTION 15.207(a)

Result                   : PASSED

EUT                      : Access controller                                                                         Date: May 15, 2019

Detector                 : CISPR Quasi-Peak (6 dB Bandwidth: 9 kHz)
Tested Line              : HOT LINE




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 10 of 15                         Report No.: OT-196-RWD-001


Tested Line              : NEUTRAL LINE




Remark: Margin (dB) = Limit – Level (Result)
          The emission level in above table is included the transducer factor that means insertion loss (LISN),
          cable loss and attenuator.




                                                                                                Tested by: Tae Sun, Lee / Engineer




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 11 of 15                          Report No.: OT-196-RWD-001


5.2 Radiated Emission Test below 30 MHz

The following table shows the highest levels of radiated emission on both polarizations of horizontal and vertical.


Humidity Level                    : 47 % R.H.                                                                        Temperature: 23 ˚C
Limits apply to                   : FCC CFR 47, PART 15, SUBPART C, SECTION 15.209
Type of Test                      : Low Power Transmitter below 1 705 kHz
Result                            : PASSED


EUT                               : Access controller                                               Date: May 23, 2019 ~ May 27, 2019
Distance                          :3m

   Frequency         Reading Ant. Pol.    Ant.    Angle Ant. Factor Cable                             Emission     Limits Margin
     (MHz)           (dBμV)   (H/V)    Height (m)  (°)   (dB/m)     Loss                           Level(dBμV/m) (dBμV/m) (dB)

      0.015            43.26          H               1           180         20.01         0.05        63.32            183.5      120.18
      0.033            40.24          H               1           180         20.11         0.06        60.41            177.8      117.39
      0.064            36.58          H               1           180         20.15         0.05        56.78            171.6      114.82
     0.132 5           68.36          H               1           360         20.23         0.05        88.64            165.7      77.06
      0.248            44.62          H               1           360         20.23         0.06        64.91            159.6      94.69
      0.663            35.28          H               1           180         20.25         0.07         55.6            110.9      55.30
                                            Radiated Emission Tabulated Data below 30 MHz
  Note: According to the distance of measurements was reduced to 3 m, the limit was extrapolated by using the square of
          an inverse linear distance extrapolation factor (40 dB/decade) as follows.
          Limit calculation: Limit at specified distance + 40log (300/3) = Limit + 80 dB for up to 0.49 MHz
                                Limit at specified distance + 40log (30/3) = Limit + 40 dB for above 0.49 MHz




                                                                                                   Tested by: Tae Sun, Lee / Engineer




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 12 of 15                         Report No.: OT-196-RWD-001


5.3 Radiated Emission Test above 30 MHz

The following table shows the highest levels of radiated emission on both polarizations of horizontal and vertical.


Humidity Level           : (49 ~ 50) % R.H.                                                                   Temperature: (22 ~ 23) ºC
Limits apply to          : FCC CFR 47, PART 15, SUBPART C, SECTION 15.209
Detector                 : CISPR Quasi-Peak (6 dB Bandwidth: 120 kHz)
Type of Test             : Low Power Transmitter below 1 705 kHz


EUT                      : Access controller                                                                       Date: May 15, 2019
Distance                 :3m




                                                                                                Tested by: Tae Sun, Lee / Engineer
It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 13 of 15                         Report No.: OT-196-RWD-001


5.4 Bandwidth of the operating frequency

Humidity Level                             : 47 % R.H.                                                             Temperature: 23 ˚C
Limits apply to                            : FCC CFR 47, PART 15, SUBPART C, SECTION 15.209
Type of Test                               : Low Power Transmitter below 1 705 kHz


EUT                                        : Access controller                                      Date: May 23, 2019 ~ May 27, 2019
Resolution Bandwidth                       : 1.0 kHz
Video Bandwidth                            : 3.0 kHz
SPAN                                       : 10.00 kHz

   Carrier Freq.            Bandwidth of the emission.                 Limit
                                                                                                         Remark
        (kHz)                             (kHz)                        (kHz)

         132.5                            3.906                        None           The point 20 dB down from the modulated carrier

Remark: Please refer to Photo Data for bandwidth for test data.




                                                                                                  Tested by: Tae Sun, Lee / Engineer

Photo Data for bandwidth




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 14 of 15                         Report No.: OT-196-RWD-001


6. FIELD STRENGTH CALCULATION

Meter readings are compared to the specification limit correcting for antenna and cable losses.




                                              +    Meter reading                     (dBμV)
                                              -   Amplifier Gain                     (dB)
                                              +    Cable Loss                        (dB)
                                              -   Antenna Factor                     (dB/m)
                                              =    Corrected Result                  (dBμV/m)


                                              Margin (dB)
                                                   Specification Limit               (dBuV/m)
                                              -    Corrected Result                  (dBuV/m)
                                              =    dB Relative to Spec               (± dB)




It should not be reproduced except in full, without the written approval of ONETECH Corp.                                   EMC-003 (Rev.2)
ONETECH Corp.: 43-14, Jinsaegol-gil, Chowol-eup, Gwangju-si, Gyeonggi-do, 12735, Korea (TEL: 82-31-799-9500, FAX: 82-31-799-9599)


                                                               Page 15 of 15                         Report No.: OT-196-RWD-001


7. LIST OF TEST EQUIPMENT

 No.        EQUIPMENTS                    MFR.                MODEL               SER. NO.        LAST CAL             DUE CAL       USE

  1.                                        R/S                 ESCI                101012        Oct. 22, 2018        One Year        -
  2.          Test receiver                 R/S                  ESR                101470        Oct. 22, 2018        One Year       
  3.                                        R/S                 ESPI                101278        Oct. 20, 2018        One Year       
  4.       Spectrum analyzer                R/S                FSV30                101372       Aug. 23, 2018         One Year       
                                         Sonoma
  5.            Amplifier                                       310N                312544       Mar. 18, 2019         One Year       
                                        Instrument
                                         Sonoma
  6.            Amplifier                                       310N                312545       Mar. 18, 2019         One Year        -
                                        Instrument
         TRILOG Broadband
  7.                                  Schwarzbeck           VULB9163               9163-255       Jun. 05, 2018        Two Year       
                 Antenna
         TRILOG Broadband
  8.                                  Schwarzbeck           VULB9163               9163-419      Aug. 09, 2018         Two Year        -
                 Antenna
                                                                                CO3000/904/
  9.           Controller             Innco System            CO3000                                   N/A                 N/A        
                                                                                 37211215/L
                                                                                  9109-1867      Mar. 27, 2019         One Year        -
                                          EMCO                 3825/2
                                                                                  9109-1869      Mar. 19, 2019         One Year       
 10.              LISN
                                      Schwarzbeck           NNLK8121                  804         Oct. 22, 2018        One Year       
                                      Schwarzbeck           NSLK8128               8128-216      Mar. 20, 2019         One Year       
 11.           Turn Table             Innco System            DT3000                930611             N/A                 N/A        
 12.        Antenna Master            Innco System          MA4000-EP           MA4000/332             N/A                 N/A         -
 13.        Antenna Master            Innco System        MA-4000XPET           MA4000/509             N/A                 N/A        
 14.         Loop Antenna             Schwarzbeck           FMZB 1513              1513-235       May 13, 2018         Two Year       
 15.      Frequency Counter                 HP                53152A             US39270295      Aug. 23, 2018         One Year       
          Environmental Test
 16.                                      ESPEC               PSL-2KP             14009407        Feb. 22, 2019        One Year       
                Chamber
 17.       DC Power Supply                Protek            PWS-3003D              4020409       Aug. 24, 2018         One Year       