MPE Prediction

FCC ID: XWX-LOS5000

RF Exposure Info

Download: PDF
FCCID_1393612

                                                                       the wireless lab

9th December 2010
FCC, Part 15 Subpart C §15.407(f)
Industry Canada RSS-Gen §5.5

Calculations for Maximum Permissible Exposure Levels

       Power Density = Pd (mW/cm2) = EIRP/(4πd2)
       EIRP = P * G
       P = Peak output power (mW)
       G = Antenna numeric gain (numeric)
       d = Separation distance (cm)
       Numeric Gain = 10 ^ (G (dBi)/10)
The peak power in the table below is calculated by assuming a worst case scenario
where all of the EUT transmitters are operating simultaneously in the same band. The
Peak Power in mW is the highest transmitter power measured and summed across all
transmitters.

Because the EUT belongs to the General Population/Uncontrolled Exposure the limit of
power density is 1.0 mW/cm2

                                                                             Calculated
                                                   Peak          Peak                      Minimum
                                  Numeric                                       Safe
 Freq. Band      Antenna                          Output        Output                    Separation
                                   Gain                                      Distance @
   (MHz)         Gain (dBi)                       Power         Power                      Distance
                                 (numeric)                                    1mW/cm2
                                                  (dBm)         (mW)                         (cm)
                                                                              Limit(cm)
 2400 – 2500         3.0              2.0          18.52         71.12            3.4       20.00

*Note: for mobile or fixed location transmitters the minimum separation distance is 20cm,
even if calculations indicate the MPE distance to be less.

Specification
Maximum Permissible Exposure Limits

§15.247(i) Systems operating under the provisions of this section shall be operated in a
manner that ensures that the public is not exposed to radio frequency levels in excess of
the Commission’s guidelines.

FCC §1.1310 Limit = 1mW / cm2 from 1.310 Table 1

RSS-Gen §5.5 Before equipment certification is granted, the application requirements of
RSS-102 shall be met.




                     MiCOM Labs, 440 Boulder Court, Suite 200, Pleasanton, CA 94566
                Tel: +1 (925) 462-0304, Fax: +1 (925) 462-0306, Web: www.micomlabs.com



Document Created: 2010-12-09 20:16:24
Document Modified: 2010-12-09 20:16:24

© 2024 FCC.report