Test report

FCC ID: XVBA1B01

Test Report

Download: PDF
FCCID_1518260

                Compliance Certification Services Inc.
                                                   FCC ID: XVBA1B01         Report No.: T100914406-RP1



                           FCC 47 CFR PART 15 SUBPART C


                                         TEST REPORT


                                                  For


                                           TPM Sensor


                                         Model: PA1-007

    Data Applies To : PA1-001; PA1-002; PA1-003; PA1-004; PA1-005;
                  PA1-008; PA1-011; PA1-012; PA1-013


                                       Trade Name: SMP

                                                Issued to

                              Standard Motor Products, Inc.
                37-18 Northern Boulevard, Long Island City, New York 11101

                                                Issued by

                       Compliance Certification Services Inc.
                                      Tainan Lab.
                     No. 8, Jiu Ceng Ling, Jiaokeng Village, Sinhua
                     Township, Tainan Hsien 712, Taiwan (R.O.C.)
                                  TEL: (06) 580-2201
                                  FAX: (06) 580-2202

                              Issued Date : August 05, 2011




Note: This report shall not be reproduced except in full, without the written approval of Compliance
Certification Services Inc. This document may be altered or revised by Compliance Certification
Services Inc. personnel only, and shall be noted in the revision section of the document.



                                               Page 1 / 31


         Compliance Certification Services Inc.
                                    FCC ID: XVBA1B01          Report No.: T100914406-RP1




                             REVISION HISTORY

Rev.     Issue Date            Revisions           Effect Page         Revised By


00     March 28, 2011          Initial Issue            ALL           Sunny Chang


01      May 11, 2011          Add test data            Page 15        Sunny Chang


02      July 25, 2011       Update test data       Page 22~24         Sunny Chang

                                                      Page
03      July 29, 2011       Update test data                          Sunny Chang
                                                  15,17,18,22-24

                                                   Page 13-14,
04     August 05, 2011      Update test data                          Sunny Chang
                                                     22-24




                                    Page 2 / 31


                      Compliance Certification Services Inc.
                                                                     FCC ID: XVBA1B01                            Report No.: T100914406-RP1




                                                TABLE OF CONTENTS
1. TEST RESULT CERTIFICATION .............................................................................................. 4

2. EUT DESCRIPTION ..................................................................................................................... 5

3. TEST METHODOLOGY .............................................................................................................. 6
   3.1       EUT CONFIGURATION ................................................................................................................. 6
   3.2       EUT EXERCISE ........................................................................................................................... 6
   3.3       GENERAL TEST PROCEDURES..................................................................................................... 6
   3.4       FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS.................................................. 7
   3.5       DESCRIPTION OF TEST MODES .................................................................................................... 7


4. INSTRUMENT CALIBRATION................................................................................................... 8
   4.1       MEASURING INSTRUMENT CALIBRATION .................................................................................. 8
   4.2       MEASUREMENT EQUIPMENT USED .................................................................................. 8
   4.3       MEASUREMENT UNCERTAINTY ......................................................................................... 9

5. FACILITIES AND ACCREDITATIONS ................................................................................... 10
   5.1       FACILITIES.............................................................................................................................. 10
   5.2       EQUIPMENT ............................................................................................................................. 10
   5.3       TABLE OF ACCREDITATIONS AND LISTINGS................................................................................. 11


6. SETUP OF EQUIPMENT UNDER TEST ................................................................................ 12
   6.1       SETUP CONFIGURATION OF EUT ................................................................................................ 12
   6.2       SUPPORT EQUIPMENT .............................................................................................................. 12


7. FCC PART 15.231 REQUIREMENTS..................................................................................... 13
   7.1       20DB BANDWIDTH............................................................................................................... 13
   7.2       LIMIT OF TRANSMISSION TIME ................................................................................................... 15
   7.3       DUTY CYCLE CORRECTION FACTOR .............................................................................. 17
   7.4       RADIATED EMISSIONS .............................................................................................................. 19
   7.5       POWERLINE CONDUCTED EMISSIONS ........................................................................................ 26


APPENDIX I PHOTOGRAPHS OF TEST SETUP....................................................................... 27

APPENDIX 1 - PHOTOGRAPHS OF EUT




                                                                      Page 3 / 31


                Compliance Certification Services Inc.
                                           FCC ID: XVBA1B01          Report No.: T100914406-RP1




1. TEST RESULT CERTIFICATION

Applicant:                     Standard Motor Products, Inc.
                               37-18 Northern Boulevard, Long Island City, New York
                               11101
Equipment Under Test:          TPM Sensor
Trade Name:                    SMP
Model:                         PA1-007
Data Applies To                 PA1-001; PA1-002; PA1-003; PA1-004; PA1-005; PA1-008;
                                PA1-011; PA1-012; PA1-013
Date of Test:                  October 13, 2010 ~ August 04, 2011

                               APPLICABLE STANDARDS

                   STANDARD                                   TEST RESULT

       FCC 47 CFR Part 15 Subpart C                      No non-compliance noted


We hereby certify that:
The above equipment was tested by Compliance Certification Services Inc. The test data,
data evaluation, test procedures, and equipment configurations shown in this report
were made in accordance with the procedures given in ANSI C63.4: 2003 and the
energy emitted by the sample EUT tested as described in this report is in compliance
with conducted and radiated emission limits of FCC Rules Part 15.207, 15.209 and Part
15.231(e).
The test results of this report relate only to the tested sample identified in this report.




Approved by:                                        Reviewed by:




Jeter Wu                                            Eric Huang
Assistant Manager                                   Assistant Section Manager
Compliance Certification Services Inc.              Compliance Certification Services Inc.




                                           Page 4 / 31


              Compliance Certification Services Inc.
                                         FCC ID: XVBA1B01        Report No.: T100914406-RP1




2. EUT DESCRIPTION

Product                      TPM Sensor


Trade Name                   SMP


Model Number                 PA1-007


                             PA1-001; PA1-002; PA1-003; PA1-004; PA1-005; PA1-008;
Data Applies To
                             PA1-011; PA1-012; PA1-013

                             To add a series model is for business necessary. The
Model Difference
                             products are all the same except for different model number.

Power Supply                 battery 3Vdc


Frequency Range              315 MHz


Modulation Technique         FSK Modulation (Single mode)


Antenna Designation          Monopole Antenna

Remark:
   1.     The sample selected for test was engineering sample that approximated to
          production product and was provided by manufacturer.
   2.     This submittal(s) (test report) is intended for FCC ID: XVBA1B01 filing to
          comply with Section 15.207, 15.209 and 15.231(e) of the FCC Part 15, Subpart
          C Rules.




                                         Page 5 / 31


             Compliance Certification Services Inc.
                                        FCC ID: XVBA1B01         Report No.: T100914406-RP1



3. TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.4
(2003) and FCC CFR 47 2.1046, 2.1047, 2.1049, 2.1051, 2.1053, 2.1055, 2.1057,
15.207, 15.209 and 15.231(e).
3.1 EUT CONFIGURATION
The EUT configuration for testing is installed on RF field strength measurement to meet
the Commissions requirement and operating in a manner that intends to maximize its
emission characteristics in a continuous normal application.
3.2 EUT EXERCISE
The EUT was operated in the engineering mode to fix the TX frequency that was for the
purpose of the measurements.
3.3 GENERAL TEST PROCEDURES
Conducted Emissions
The EUT is placed on the turntable, which is 0.8 m above ground plane. According to the
requirements in Section 13.1.4.1 of ANSI C63.4. Conducted emissions from the EUT
measured in the frequency range between 0.15 MHz and 30MHz using CISPR
Quasi-peak and average detector modes.

Radiated Emissions
The EUT is placed on a turn table, which is 0.8 m above ground plane. The turntable
shall rotate 360 degrees to determine the position of maximum emission level. EUT is
set 3m away from the receiving antenna, which varied from 1m to 4m to find out the
highest emission. And also, each emission was to be maximized by changing the
polarization of receiving antenna both horizontal and vertical. In order to find out the
maximum emissions, exploratory radiated emission measurements were made
according to the requirements in Section 13.1.4.1 of ANSI C63.4.




                                        Page 6 / 31


               Compliance Certification Services Inc.
                                           FCC ID: XVBA1B01       Report No.: T100914406-RP1




3.4 FCC PART 15.205 RESTRICTED BANDS OF OPERATIONS
(a) Except as shown in paragraph (d) of this section, only spurious emissions are
    permitted in any of the frequency bands listed below:

              MHz                    MHz                 MHz               GHz
           0.090 - 0.110      16.42 - 16.423     399.9 - 410            4.5 - 5.15
          1
           0.495 - 0.505   16.69475 - 16.69525    608 - 614            5.35 - 5.46
         2.1735 - 2.1905   16.80425 - 16.80475   960 - 1240            7.25 - 7.75
          4.125 - 4.128         25.5 - 25.67     1300 - 1427           8.025 - 8.5
        4.17725 - 4.17775       37.5 - 38.25    1435 - 1626.5            9.0 - 9.2
        4.20725 - 4.20775         73 - 74.6    1645.5 - 1646.5           9.3 - 9.5
          6.215 - 6.218         74.8 - 75.2      1660 - 1710           10.6 - 12.7
        6.26775 - 6.26825      108 - 121.94    1718.8 - 1722.2         13.25 - 13.4
        6.31175 - 6.31225        123 - 138       2200 - 2300           14.47 - 14.5
          8.291 - 8.294       149.9 - 150.05     2310 - 2390           15.35 - 16.2
          8.362 - 8.366        156.52475 -      2483.5 - 2500          17.7 - 21.4
        8.37625 - 8.38675        156.52525       2655 - 2900          22.01 - 23.12
        8.41425 - 8.41475      156.7 - 156.9     3260 - 3267           23.6 - 24.0
          12.29 - 12.293    162.0125 - 167.17    3332 - 3339           31.2 - 31.8
       12.51975 - 12.52025    167.72 - 173.2    3345.8 - 3358          36.43 - 36.5
       12.57675 - 12.57725       240 - 285       3600 - 4400                 ( 2)
          13.36 - 13.41         322 - 335.4
   1
       Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
   2
       Above 38.6

(b) Except as provided in paragraphs (d) and (e), the field strength of emissions
    appearing within these frequency bands shall not exceed the limits shown in Section
    15.209. At frequencies equal to or less than 1000 MHz, compliance with the limits in
    Section 15.209 shall be demonstrated using measurement instrumentation
    employing a CISPR quasi-peak detector. Above 1000 MHz, compliance with the
    emission limits in Section 15.209 shall be demonstrated based on the average value
    of the measured emissions. The provisions in Section 15.35 apply to these
    measurements.
3.5 DESCRIPTION OF TEST MODES
After the preliminary test, the EUT (model: PA1-007 had found to emit the worst
emissions and therefore had been tested under normal operating and standby condition.
Hardware used to control the EUT for staying in continuous transmitting and receiving
mode for testing.




                                           Page 7 / 31


             Compliance Certification Services Inc.
                                        FCC ID: XVBA1B01          Report No.: T100914406-RP1




4. INSTRUMENT CALIBRATION
4.1 MEASURING INSTRUMENT CALIBRATION
The measuring equipment, which was utilized in performing the tests documented herein,
has been calibrated in accordance with the manufacturer's recommendations for utilizing
calibration equipment, which is traceable to recognized national standards
4.2 MEASUREMENT EQUIPMENT USED
Equipment Used for Emissions Measurement
                                Open Area Test Site # 6
     Name of                                                  Serial
                    Manufacturer           Model                          Calibration Due
    Equipment                                                Number
TYPE N COAXIAL
                     SUHNER              CHA9513                  6         NOV. 17, 2011
    CABLE
 BI-LOG Antenna        Sunol                 JB1            A070506-2       OCT. 04, 2011

LOOP ANTENNA           EMCO                 6502            8905-2356       JUN. 10, 2012

   Pre-Amplifier         HP                8447F           2944A03817       NOV. 23, 2011

  EMI Receiver          R&S               ESVS10           833206/012        MAY 10, 2012

    RF Cable         SUHNER         SUCOFLEX104PEA 20520/4PEA               NOV. 10, 2011

  Horn Antenna      Com-Power             AH-118             071032         DEC. 27, 2011

Spectrum Analyzer       R&S               FSEK 30          835253/002        JUL. 14, 2012
                                   AFS44-00108650-42-1
   Pre-Amplifier       MITEQ                                 1205908        NOV. 23, 2011
                                          0P-44
    Turn Table        Yo Chen                001             ----------          N.C.R.

  Antenna Tower          AR              TP1000A             309874              N.C.R.

    Controller           CT                SC101             ----------          N.C.R.
                    E-INSTRUME
    RF Swicth                            ERS-180A          EC1204141             N.C.R
                    NT TELH LTD
     Test S/W                                    e-3 (5.04303e)

Remark: Each piece of equipment is scheduled for calibration once a year.




                                        Page 8 / 31


        Compliance Certification Services Inc.
                                   FCC ID: XVBA1B01         Report No.: T100914406-RP1




4.3 MEASUREMENT UNCERTAINTY
                 PARAMETER                        UNCERTAINTY
      Radiated Emission, 30 to 200 MHz
                                                      ±3.59dB
             Test Site : OATS-6
    Radiated Emission, 200 to 1000 MHz
                                                      ±3.27dB
            Test Site : OATS-6

      Radiated Emission, 1 to 26.5 GHz                ± 3.20dB

       Power Line Conducted Emission                  ± 2.90dB

  Uncertainty figures are valid to a confidence level of 95%, k=2




                                   Page 9 / 31


             Compliance Certification Services Inc.
                                        FCC ID: XVBA1B01         Report No.: T100914406-RP1



5. FACILITIES AND ACCREDITATIONS
5.1 FACILITIES
All measurement facilities used to collect the measurement data are located at
   No. 8, Jiu Ceng Ling, Jiaokeng Village,Sinhua Township, Tainan Hsien 712,
Taiwan (R.O.C.)
The sites are constructed in conformance with the requirements of ANSI C63.7:1992,
ANSI C63.4 : 2003 and CISPR Publication 22.
5.2 EQUIPMENT
Radiated emissions are measured with one or more of the following types of linearly
polarized antennas: tuned dipole, biconical, log periodic, bi-log, and/or ridged waveguide,
horn. Spectrum analyzers with pre-selectors and quasi-peak detectors are used to
perform radiated measurements.
Conducted emissions are measured with Line Impedance Stabilization Networks and
EMI Test Receivers.
Calibrated wideband preamplifiers, coaxial cables, and coaxial attenuators are also used
for making measurements.
All receiving equipment conforms to CISPR Publication 16-1, “Radio Interference
Measuring Apparatus and Measurement Methods.”




                                        Page 10 / 31


             Compliance Certification Services Inc.
                                        FCC ID: XVBA1B01        Report No.: T100914406-RP1




5.3 TABLE OF ACCREDITATIONS AND LISTINGS
Our laboratories are accredited and approved by the following accreditation body
according to ISO/IEC 17025.

           Taiwan              TAF

The measuring facility of laboratories has been authorized or registered by the following
approval agencies.

          Canada              Industry Canada
          Germany             TÜV NORD
          Taiwan              BSMI
          USA                 FCC


Copies of granted accreditation certificates are available for downloading from our web
site, http://www.ccsrf.com




                                        Page 11 / 31


               Compliance Certification Services Inc.
                                               FCC ID: XVBA1B01             Report No.: T100914406-RP1




6. SETUP OF EQUIPMENT UNDER TEST
6.1 SETUP CONFIGURATION OF EUT
See test photographs attached in Appendix I for the actual connections between EUT
and support equipment.
6.2 SUPPORT EQUIPMENT
No.       Product        Manufacturer           Model No.     Certify No.           Signal cable
 1            N/A             -------              -------        -------               -------

No. Signal cable description

 A      N/A                         --------

Remark:
     1. All the equipment/cables were placed in the worst-case configuration to maximize
        the emission during the test.
     2. Grounding was established in accordance with the manufacturer’s requirements
        and conditions for the intended use.




                                               Page 12 / 31


              Compliance Certification Services Inc.
                                         FCC ID: XVBA1B01     Report No.: T100914406-RP1



7. FCC PART 15.231 REQUIREMENTS
7.1 20DB BANDWIDTH

LIMIT
The bandwidth of the emission shall be no wider than 0.25% of the center frequency for
devices operating above 70 MHz and below 900 MHz. For devices operating above 900
MHz, the emission shall be no wider than 0.5% of the center frequency. Bandwidth is
determined at the points 20 dB down from the modulated carrier.
Test Configuration


                     Spectrum
    EUT              Analyzer



TEST PROCEDURE
The transmitter output is connected to the spectrum analyzer. The spectrum analyzer
center frequency is set to the transmitter frequency. The RBW is set to 10 kHz and VBW
is set 30kHz.
TEST RESULTS
No non-compliance noted.

Test Data

   Frequency             20dB                   Limit
                       Bandwidth                              Result
      (MHz)                                    (KHz)
                          (KHz)

        315           136.2725451              787.5          PASS




                                         Page 13 / 31


            Compliance Certification Services Inc.
                                       FCC ID: XVBA1B01   Report No.: T100914406-RP1



Test Plot




                                       Page 14 / 31


              Compliance Certification Services Inc.
                                         FCC ID: XVBA1B01        Report No.: T100914406-RP1




7.2 LIMIT OF TRANSMISSION TIME

LIMIT
According to 15.231(e), in addition, devices operated under the provisions of this
paragraph shall be provided with a means for automatically limiting operation so that the
duration of each transmission shall not be greater than one second and the silent period
between transmissions shall be at least 30 times the duration of the transmission but in
no case less than 10 seconds.

Test Configuration


                     Spectrum
    EUT              Analyzer




TEST PROCEDURE
The transmitter output is connected to the spectrum analyzer. The spectrum analyzer
center frequency is set to the transmitter frequency. The RBW and VBW are set to
1MHz.

TEST RESULTS
No non-compliance noted

Test Data

Limit of transmission time
 Frequency     Transmission Time         Limit
                                                        Result
   (MHz)              (s)              (Second)
     315              0.2004                1           PASS

Silent period between transmission

  Frequency       silent period between transmissions         Limit         Result
    (MHz)                          (s)                      (Second)
     315                       60.460922                       10           PASS




                                         Page 15 / 31


            Compliance Certification Services Inc.
                                       FCC ID: XVBA1B01   Report No.: T100914406-RP1



Test Plot
transmission time




silent period between transmissions




                                       Page 16 / 31


              Compliance Certification Services Inc.
                                         FCC ID: XVBA1B01        Report No.: T100914406-RP1




7.3 DUTY CYCLE CORRECTION FACTOR

LIMIT
Nil (No dedicated limit specified in the Rules)

Test Configuration



    EUT              Spectrum
                     Analyzer



TEST PROCEDURE
1. Place the EUT on the table and set it in transmitting mode.
2. Remove the antenna from the EUT and then connect a low loss RF cable from the
   antenna port to the spectrum analyzer.
3. Set center frequency of spectrum analyzer = operating frequency.
4. Set the spectrum analyzer as RBW, VBW=1MHz, Span = 0Hz, Adjust Sweep =
   100ms.
5. Repeat above procedures until all frequency measured were complete.

TEST RESULTS
No non-compliance noted

Test Data
Tp =200.4008ms
Ton = 15.719ms*5 times= 78.595ms
Factor = 20 *log(Ton / Tp) = 20 * log(78.595/100) = -2.092dB
Remark: Tp>100ms. Use 100ms for calcuation.




                                         Page 17 / 31


            Compliance Certification Services Inc.
                                       FCC ID: XVBA1B01   Report No.: T100914406-RP1



Test Plot
Ton




Tp




                                       Page 18 / 31


              Compliance Certification Services Inc.
                                            FCC ID: XVBA1B01           Report No.: T100914406-RP1




7.4 RADIATED EMISSIONS
LIMIT
1. According to §15.231(e), intentional radiators may operate at a periodic rate exceeding
   that specified in paragraph (a) and may be employed for any type of operation, including
   operation prohibited in paragraph (a), provided the intentional radiator complies with the
   provisions of paragraphs (b) through (d) of this Section, except the field strength table in
   paragraph (b) is replaced by the following:
                                         Field Strength of               Field Strength of
     Fundamental Frequency
                                           Fundamental                 Spurious Emissions
            (MHz)
                                        (microvolts/meter)              (microvolts/meter)
             40.66 – 40.70                       1000                             100
               70 – 130                          500                              50
               130 – 174                    500 to 1500 **                    50 to 150 **
               174 – 260                         1500                             150
               260 – 470                    1500 to 5000 **                  150 to 500 **
              Above 470                          5000                             500
   Remark: ** linear interpolations
   [Where F is the frequency in MHz, the formulas for calculating the maximum permitted
   fundamental field strengths are as follows: for the band 130-174 MHz, uV/m at 3 meters =
   22.72727(F) - 2454.545; for the band 260-470 MHz, uV/m at 3 meters = 16.6667(F) -
   2833.3333. The maximum permitted unwanted emission level is 20 dB below the maximum
   permitted fundamental level.]
2. Except as provided elsewhere in this Subpart, the emissions from an intentional
   radiator shall not exceed the field strength levels specified in the following table:
             Frequency                     Field Strength            Measurement Distance
               (MHz)                           (mV/m)                        (m)
               30-88                            100*                          3
               88-216                            150*                              3
               216-960                           200*                              3
             Above 960                           500                               3
   Remark: Except as provided in paragraph (g), fundamental emissions from intentional
   radiators operating under this Section shall not be located in the frequency bands 54-72 MHz,
   76-88 MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency
   bands is permitted under other sections of this Part, e.g., Sections 15.231 and 15.241.
3. In the above emission table, the tighter limit applies at the band edges.
             Frequency                     Field Strength                 Field Strength
               (MHz)                     (μV/m at 3-meter)             (dBμV/m at 3-meter)
               30-88                             100                            40
               88-216                            150                             43.5
               216-960                           200                              46
             Above 960                           500                              54



                                           Page 19 / 31


                Compliance Certification Services Inc.
                                              FCC ID: XVBA1B01             Report No.: T100914406-RP1



Test Configuration
Below 1 GHz

                                                                       Antenna
                                                                        tower


                             3m                                         Bi-log
                                                                       antenna
        EUT
                                    4m
                                                                     Spectrum
                                                                     analyzer


              Turntable                  1m
                            0.8m




   Reference ground plane


Above 1 GHz

                                                                  Antenna
                                                                   tower


                     3m                                           Horn
                                                                 antenna
  EUT
                             4m
                                                                 Spectrum
                                                                 analyzer


      Turntable                    1m
                   0.8m
                                                                    Pre-amp




                                              Page 20 / 31


             Compliance Certification Services Inc.
                                        FCC ID: XVBA1B01       Report No.: T100914406-RP1




TEST PROCEDURE
1. The EUT is placed on a turntable, which is 0.8m above ground plane.
2. The turntable shall be rotated for 360 degrees to determine the position of maximum
   emission level.
3. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find
   out the highest emissions.
4. Maximum procedure was performed on the six highest emissions to ensure EUT
   compliance.
5. And also, each emission was to be maximized by changing the polarization of
   receiving antenna both horizontal and vertical.
6. Set the spectrum analyzer in the following setting as:
   Below 1GHz:
              RBW=100kHz / VBW=300kHz / Sweep=AUTO
   Above 1GHz:
               (a) PEAK: RBW=VBW=1MHz / Sweep=AUTO
               (b) AVERAGE: RBW=1MHz / VBW=10Hz / Sweep=AUTO
7. Repeat above procedures until the measurements for all frequencies are complete.




                                        Page 21 / 31


                      Compliance Certification Services Inc.
                                                     FCC ID: XVBA1B01              Report No.: T100914406-RP1



 Below 1 GHz
 Operation
                              Tx / X Mode                    Test Date:            August 04, 2011
 Mode:
 Temperature:                 20.3°C                         Tested by:               John Chen
 Humidity:                    51 % RH                        Polarity:                    Ver. / Hor.

                                                               Duty
Freq- Antenna Cable              Meter Reading      Limits           Emission Level
                                                              Cycle                                Margin
Uency                                                                                                               Detector
       Factor Loss               at 3 m(dBμV)                 Factor at 3 m(dBμV/m)
                                                                                                                     Mode
(MHz)     (dB/m)      (dB) Horizontal Vertical (dBμV/M) (dB) Horizontal Vertical Horizontal Vertical

315.01        14.50   2.51       48.38      36.24   87.66      -2.09     65.38    53.24       -22.28    -34.42        PK
315.01        14.50   2.51        N/A       N/A     67.66      -2.09     63.29    51.15       -4.37     -16.51       AVG
629.90        19.71   3.62       20.75      19.63   67.66      -2.09     44.09    42.97       -23.57    -24.69        PK
629.90        19.71   3.62        N/A       N/A     47.66      -2.09     41.99    40.87       -5.67     -6.79        AVG
945.03        23.61   4.57       18.63      18.16   67.66      -2.09     46.81    46.34       -20.85    -21.32        PK
945.03        23.61   4.57        N/A       N/A     47.66      -2.09     44.72    44.25       -2.94     -3.41        AVG
 N/A          -----   -----       -----     -----    -----     -----      -----   -----        -----        -----     -----

 Remark:
         1.     Measuring frequencies from 30 MHz to the 1GHz.
         2.     Radiated emissions measured in frequency range from 30 MHz to 1000MHz
                were made with an instrument using peak/quasi-peak/average detector mode.
         3.     Average/quasi-peak test would be performed if the peak result were greater
                than the average/quasi-peak limit or as required by the applicant.
         4.     Data of measurement within this frequency range shown “ --- ” in the table
                above means the reading of emissions are attenuated more than 20dB below
                the permissible limits or the field strength is too small to be measured.
         5.     Measurements above show only up to 6 maximum emissions noted, or would
                be lesser, with “ N/A ” remark, if no specific emissions from the EUT are
                recorded (ie: margin>20dB from the applicable limit) and considered that's
                already beyond the background noise floor.
         6.     Margin (dB) = Remark Result (dBuV/m) – Limit (dBuV/m).




                                                     Page 22 / 31


                  Compliance Certification Services Inc.
                                                 FCC ID: XVBA1B01              Report No.: T100914406-RP1




 Operation
                          Tx / Y Mode                    Test Date:            August 04, 2011
 Mode:
 Temperature:             20.3°C                         Tested by:               John Chen
 Humidity:                51 % RH                        Polarity:                    Ver. / Hor.

                                                           Duty
Freq- Antenna Cable          Meter Reading      Limits           Emission Level
                                                          Cycle                                Margin
Uency                                                                                                           Detector
       Factor Loss           at 3 m(dBμV)                 Factor at 3 m(dBμV/m)
                                                                                                                 Mode
(MHz)    (dB/m)   (dB) Horizontal Vertical (dBμV/M) (dB) Horizontal Vertical Horizontal Vertical

315.03   14.50    2.51       36.75      43.28   87.66      -2.09     53.75    60.28       -33.91    -27.38        PK
315.03   14.50    2.51        N/A       N/A     67.66      -2.09     51.66    58.19       -16.00    -9.47        AVG
630.02   19.72    3.62       18.26      18.61   67.66      -2.09     41.60    41.95       -26.06    -25.71        PK
630.02   19.72    3.62        N/A       N/A     47.66      -2.09     39.51    39.86       -8.15     -7.80        AVG
945.06   23.62    4.57       20.37      21.26   67.66      -2.09     48.55    49.44       -19.11    -18.22        PK
945.06   23.62    4.57        N/A       N/A     47.66      -2.09     46.46    47.35       -1.20     -0.31        AVG
 N/A      -----   -----       -----     -----    -----     -----      -----   -----        -----        -----     -----

 Remark:
 1.Measuring frequencies from 30 MHz to the 1GHz.
 2.Radiated emissions measured in frequency range from 30 MHz to 1000MHz were
   made with an instrument using peak/quasi-peak/average detector mode.
 3.Average/quasi-peak test would be performed if the peak result were greater than the
   average/quasi-peak limit or as required by the applicant.
 4.Data of measurement within this frequency range shown “ --- ” in the table above
   means the reading of emissions are attenuated more than 20dB below the permissible
   limits or the field strength is too small to be measured.
 5.Measurements above show only up to 6 maximum emissions noted, or would be lesser,
   with “ N/A ” remark, if no specific emissions from the EUT are recorded (ie:
   margin>20dB from the applicable limit) and considered that's already beyond the
   background noise floor.
 6.Margin (dB) = Remark Result (dBuV/m) – Limit (dBuV/m).




                                                 Page 23 / 31


                  Compliance Certification Services Inc.
                                                 FCC ID: XVBA1B01              Report No.: T100914406-RP1




 Operation
                          Tx / Z Mode                    Test Date:            August 04, 2011
 Mode:
 Temperature:             20.3°C                         Tested by:               John Chen
 Humidity:                51 % RH                        Polarity:                    Ver. / Hor.

                                                           Duty
Freq- Antenna Cable          Meter Reading      Limits           Emission Level
                                                          Cycle                                Margin
Uency                                                                                                           Detector
       Factor Loss           at 3 m(dBμV)                 Factor at 3 m(dBμV/m)
                                                                                                                 Mode
(MHz)    (dB/m)   (dB) Horizontal Vertical (dBμV/M) (dB) Horizontal Vertical Horizontal Vertical

315.03   14.50    2.51       47.68      35.80   87.66      -2.09     64.68    52.80       -22.98    -34.86        PK
315.03   14.50    2.51        N/A       N/A     67.66      -2.09     62.59    50.71       -5.07     -16.95       AVG
630.06   19.72    3.62       19.06      18.11   67.66      -2.09     42.40    41.45       -25.26    -26.21        PK
630.06   19.72    3.62        N/A       N/A     47.66      -2.09     40.31    39.36       -7.35     -8.30        AVG
945.11   23.62    4.57       18.34      19.97   67.66      -2.09     46.52    48.15       -21.14    -19.51        PK
945.11   23.62    4.57        N/A       N/A     47.66      -2.09     44.43    46.06       -3.23     -1.60        AVG
 N/A      -----   -----       -----     -----    -----     -----      -----   -----        -----        -----     -----

 Remark:
 1.Measuring frequencies from 30 MHz to the 1GHz.
 2.Radiated emissions measured in frequency range from 30 MHz to 1000MHz were
   made with an instrument using peak/quasi-peak/average detector mode.
 3.Average/quasi-peak test would be performed if the peak result were greater than the
   average/quasi-peak limit or as required by the applicant.
 4.Data of measurement within this frequency range shown “ --- ” in the table above
   means the reading of emissions are attenuated more than 20dB below the permissible
   limits or the field strength is too small to be measured.
 5.Measurements above show only up to 6 maximum emissions noted, or would be lesser,
   with “ N/A ” remark, if no specific emissions from the EUT are recorded (ie:
   margin>20dB from the applicable limit) and considered that's already beyond the
   background noise floor.
 6.Margin (dB) = Remark Result (dBuV/m) – Limit (dBuV/m).




                                                 Page 24 / 31


            Compliance Certification Services Inc.
                                       FCC ID: XVBA1B01     Report No.: T100914406-RP1




Above 1 GHz


No emission found between lowest internal used/generated frequency above 1 GHz (ie:
margin>20dB from the applicable limit) and considered that's already beyond the
background noise floor, no record is required.




                                       Page 25 / 31


              Compliance Certification Services Inc.
                                         FCC ID: XVBA1B01         Report No.: T100914406-RP1




7.5 POWERLINE CONDUCTED EMISSIONS

LIMIT
According to §15.207(a), except as shown in paragraphs (b) and (c) of this section, for an
intentional radiator that is designed to be connected to the public utility (AC) power line,
the radio frequency voltage that is conducted back onto the AC power line on any
frequency or frequencies within the band 150 kHz to 30 MHz shall not exceed the limits
in the following table, as measured using a 50 µH/50 ohms line impedance stabilization
network (LISN). Compliance with the provisions of this paragraph shall be based on the
measurement of the radio frequency voltage between each power line and ground at the
power terminal. The lower limit applies at the boundary between the frequency ranges.

      Frequency Range                                   Limits (dBμV)
           (MHz)                         Quasi-peak                     Average
          0.15 to 0.50                    66 to 56*                     56 to 46*
           0.50 to 5                          56                            46
            5 to 30                           60                            50
* Decreases with the logarithm of the frequency.


Test Configuration
See test photographs attached in Appendix 1 for the actual connections between EUT
and support equipment.

TEST PROCEDURE
Not applicable (Since the EUT is powered by battery)

TEST RESULTS
Not applicable (Since the EUT is powered by battery)




                                         Page 26 / 31



Document Created: 2011-08-05 16:37:16
Document Modified: 2011-08-05 16:37:16

© 2024 FCC.report