App B_SAR System Check Plots

FCC ID: XRAFB507

RF Exposure Info

Download: PDF
FCCID_4406012

Test Laboratory: UL Verification Services Inc. SAR Lab 1                    Date/Time: 4/15/2019 9:12:05 AM

20190415_SystemPerformanceCheck-D2450V2 SN 748
Frequency: 2450 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used: f = 2450 MHz; σ = 1.819 S/m; εr = 38.101; ρ = 1000 kg/m3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1546; Calibrated: 5/3/2018
- Probe: EX3DV4 - SN3749; ConvF(6.73, 6.73, 6.73) @ 2450 MHz; Calibrated: 1/25/2019
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: SAM with CRP (Wi-Fi 5 GHz); Type: QD000P40CD; Serial: TP:xxxx

Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.08 W/kg

Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 66.72 V/m; Power Drift = -0.18 dB
Peak SAR (extrapolated) = 11.7 W/kg
SAR(1 g) = 5.62 W/kg; SAR(10 g) = 2.59 W/kg
Maximum value of SAR (measured) = 7.99 W/kg




                      0 dB = 7.99 W/kg = 9.03 dBW/kg




                                                                                                               Plot No. 1


Test Laboratory: The name of your organization       Date/Time: 4/15/2019 9:27:09 AM

20190415_SystemPerformanceCheck-D2450V2 SN 748
Frequency: 2450 MHz; Duty Cycle: 1:1

Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 7.57 W/kg




                                                                                       Plot No. 2


Test Laboratory: UL Verification Services Inc. SAR Lab 2                    Date/Time: 5/28/2019 11:53:06 AM

20190528_SystemPerformanceCheck-D2450V2 SN 748
Frequency: 2450 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0°C; Liquid Temperature: 23.0°C
Medium parameters used: f = 2450 MHz; σ = 1.883 S/m; εr = 38.632; ρ = 1000 kg/m3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1359; Calibrated: 2/15/2019
- Probe: EX3DV4 - SN7483; ConvF(7.82, 7.82, 7.82) @ 2450 MHz; Calibrated: 11/14/2018
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: Twin-SAM V8.0 (20deg probe tilt); Type: QD 000 P41 AA; Serial: 1957

Head/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 5.80 W/kg

Head/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 64.71 V/m; Power Drift = -0.06 dB
Peak SAR (extrapolated) = 11.4 W/kg
SAR(1 g) = 5.41 W/kg; SAR(10 g) = 2.49 W/kg
Maximum value of SAR (measured) = 7.72 W/kg




                      0 dB = 7.72 W/kg = 8.88 dBW/kg




                                                                                                               Plot No. 3


Test Laboratory: UL Verification Services Inc. SAR Lab 2   Date/Time: 5/28/2019 11:53:06 AM

20190528_SystemPerformanceCheck-D2450V2 SN 748
Frequency: 2450 MHz; Duty Cycle: 1:1

Head/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 7.64 W/kg




                                                                                          Plot No. 4



Document Created: 2019-06-06 07:57:25
Document Modified: 2019-06-06 07:57:25

© 2025 FCC.report