11981268 -S5V1 Appendix B

FCC ID: XRAFB504

RF Exposure Info

Download: PDF
FCCID_3756165

Test Laboratory: UL Verification Services Inc. SAR Lab 3                     Date/Time: 1/8/2018 9:33:03 AM

20180108_SystemPerformanceCheck-D2450V2 SN 899
Frequency: 2450 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
Medium parameters used: f = 2450 MHz; σ = 2.024 S/m; εr = 50.89; ρ = 1000 kg/m3
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1239; Calibrated: 7/27/2017
- Probe: EX3DV4 - SN3902; ConvF(7.89, 7.89, 7.89); Calibrated: 5/30/2017;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI A v5.0; Type: QD OVA 002 AA; Serial: 1194

Body/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 5.97 W/kg

Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 60.413 V/m; Power Drift = -0.16 dB
Peak SAR (extrapolated) = 10.9 W/kg
SAR(1 g) = 5.14 W/kg; SAR(10 g) = 2.35 W/kg
Maximum value of SAR (measured) = 7.33 W/kg




                      0 dB = 7.33 W/kg = 8.65 dBW/kg




                                                                                                               Plot No. 1


Test Laboratory: UL Verification Services Inc. SAR Lab 3    Date/Time: 1/8/2018 9:53:36 AM

20180108_SystemPerformanceCheck-D2450V2 SN 899
Frequency: 2450 MHz; Duty Cycle: 1:1

Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 7.16 W/kg




                                                                                             Plot No. 2



Document Created: 2018-03-13 12:02:38
Document Modified: 2018-03-13 12:02:38

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC