RF Exposure Info

FCC ID: XRAFB203

RF Exposure Info

Download: PDF
FCCID_4428240

                                         SGS-CSTC Standards Technical Services Co., Ltd.
                                         Guangzhou Branch

 198 Kezhu Road, Scientech Park, Guangzhou Economic & Technological
 Development District, Guangzhou, China 510663
 Telephone: +86 (0) 20 82155555                                                         Report No.: GZEM190701430203
 Fax:       +86 (0) 20 82075059
 Email:        ee.guangzhou@sgs.com
                                                                                        Page:       1 of 10


                                                  TEST REPORT
Application No.:           GZEM1907014302CR
Applicant:                 Fitbit, Inc.
Address of Applicant:      199 Fremont Street, 14th Floor San Francisco, CA 94105 USA
Manufacturer:              Fitbit, Inc.
Address of Manufacturer:   199 Fremont Street, 14th Floor San Francisco, CA 94105 USA
Factory:                   Zhongshan Transtek Electronics Co.,Ltd
Address of Factory:        No. 23,Jin'an Road, Minzhong, Zhongshan ,Guangdong, China
Equipment Under Test (EUT):
EUT Name:                  Body Scale
Model No.:                 FB203
Trade Mark:


Standard(s) :                           47 CFR Part 1.1307, Part 2.1093, KDB 447498
Date of Receipt:                        2019-07-12
Date of Test:                           2019-07-17 to 2019-08-12
Date of Issue:                          2019-08-13
Test Result:                            Pass*
* In the configuration tested, the EUT complied with the standards specified above.




               Kobe Jian
         EMC Laboratory Manager
The manufacturer should ensure that all products in series production are in conformity with the product sample detailed in this report.
If the product in this report is used in any configuration other than that detailed in the report, the manufacturer must ensure the new system
complies with all relevant standards. Any mention of SGS International Electrical Approvals or testing done by SGS International Electrical
Approvals in connection with, distribution or use of the product described in this report must be approved by SGS International Electrical
Approvals in writing.


                           SGS-CSTC Standards Technical Services Co., Ltd.
                           Guangzhou Branch
                                                           Report No.: GZEM190701430203
                                                           Page:       2 of 10


                                        Revision Record

Version      Chapter          Date          Modifier                  Remark

   01                      2019-08-13                     Original




Authorized for issue by:




Tested By
                                                                     2019-07-17 to 2019-08-12

                              Lily_Kuang /Project Engineer           Date




Checked By
                                                                     2019-08-13

                              Ricky_Liu /Reviewer                    Date


                        SGS-CSTC Standards Technical Services Co., Ltd.
                        Guangzhou Branch
                                                         Report No.: GZEM190701430203
                                                         Page:       3 of 10



2   Test Summary
    Radio Spectrum Technical Requirement
           Item              Standard              Method            Requirement        Result
                        47 CFR Part 1.1307,
       RF Exposure       Part 2.1093, KDB     CFR 47 Part 2.1093   CFR 47 Part 2.1093   Pass
                              447498


                                                                 SGS—CSTC Standards Technical Services Co., Ltd.
                                                                 Guangzhou Branch
                                                                                                                                             Report No.: GZEM190701430203
                                                                                                                                             Page:                         4 of 10



3             Contents
                                                                                                                                                                                                                           Page
1         COV@F PAG@.............«c«ssrssrrrrsrrrrrrrrrsrrrrssrssssssssssssssrssssssssssssssssssssssssssssssrsssrssssssssssssssssssssssssaassaaassassssksssskssssssnnnns 1

2         Te@St SUMIM@FY...............ccccssccsssnnsssnssssnssssssssssssssersrrrssrrssssrssssssssssssssssssssassaaaasaaassaasssaasskkskkkkkkkkkskkksskksaaa88aaa8aan 0s 3

3         CONI@MTS ...........ssss0sssserrrrrrnnnnnernrrrrrrrnnnsnsrrarrrrr snn ns arrrrrnnnnnnn n n n n n n n en n in n n n n n n n n en n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n nan n n n in n 4

4         GeN@er@l INnfOFM@TION ...............0.sssssssssssssssrrrrssssssrrrrrrsrsnnirrrrrrrrrnnnnnn in rr n n n isnn n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n n s 5
    4.1              DEet@il$ Of E.U.T.....222202222220246r¥¥¥¥eeerrrrrrrrrrrrrrrrrrrrsrrrrrsrerrrrrrerrrrrrererrrrrrer i i se arrr i iss e a i ie se e a i ie e e e aa ie es e aare e e e e k aaee8 5
    4.2              DesCription Of SUPPONt UNItS .............22..2222222222rrrrrrrvvrrvvvrrvrrsrrrssssssssrsssrssrrs iss is se is rrrrrrrrrrrrrrr e e e e e e e e e e e e e e a e e k a04 5
    4.3              Ese ifi e 5
    4.4              T@St FACIIItY .....222222222200202222¥¥446r¥¥¥¥vs 6 rrrrvvvrrrrvvrrrrravarrrr es i i k rraa is vrrrraa i a k k k ki¥ i¥ k k ki k e k k k e 6k k k e k k e e e k a e k e e e k e aa e e e k e e aa en 6
    4.5              DPEMEYi(e s icolepfheieafeCleoC 7
    4.6              Abnormalities from Stand@rd CONQItiONS ............2.....0000002222rrrrrersrrerrr s r se e e e e e e e e e e e e rrrr e e e e e e e e e e e e e e e e e e e e e e e e es 7
5         Equiipment LISt . . . . . . . . . . ... .mm mm mm mm m n n mm n m n in n n n in en n in in en n n i en n n n n en en nn kn n kn anna ns 8

6         Radio Spectrum Technical R@QUIF@M@NT ............0.000000000ssssssrrrerrrrrrrrrrrrrrrrrrrrrrrrrrrkrrsssrssssssssssnnsssnnnaaanaaaaaaaaas 9
    RF Exposure Compliance Re@QUIF@M@NT ..........................2222202222200222rrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrrr e e e e e e e e e e e e e e e e e ae. 9
7         P HOTOGNFAD NS . . . 2 2 2 2 2 2000000000000mmm im mm i ie i n n m i i in m n n e w i i n w i i n n e w i n n n e e w i i n e e i n n n e w w i n n e n i n n e n i n i n i n i n i n n e n i n n n e i i i i n i i i n n n n i 10
    7.1              d UBE Oe a[=3(gho(olaF Tb e1| ce 10




                                                  Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                                  overleaf, available on request or accessible at http://www.sqs.com/en/Terms—and—Conditions.aspx and, for electronic format documents,
                                                  subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms—and—Conditions/Terms—e—Document.aspx.
                                                  Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                                                  advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                                  Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                                                  transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
    t                 .                            except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
             trotsil] £)f o                        appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the
                                                   results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
                                                   Attention: To check the authenticity of testing /inspection report & certificate, please contact us at telephone: (86—755) 8307 1443,
                                                   or email: CN.Doccheck@sgs.com
                                                  . No.198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, China 510663 t (86—20) 82155555 f (86—20) 82075058 www.sgsgroup.com.cn
                                                    1B +N —LZLFTHRKRTEENEHEREER198S                                                    BBZZ: 510663 t (86—20) 82155555 f (86—20) 82075058 sgs.china@sgs.com
                                                                                                                                                                               Member of the SGS Group (SGS SA)


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Guangzhou Branch
                                                              Report No.: GZEM190701430203
                                                              Page:       5 of 10


4   General Information
4.1 Details of E.U.T.
    Power Supply:              DC4.5V= 3 x DC1.5V size of "AAA" batteries
    Antenna Gain               0 dBi
    Antenna Type               PCB Antenna
    Channel Spacing            2MHz
    Modulation Type            GFSK
    Number of Channels         40
    Operation Frequency        2402MHz to 2480MHz


4.2 Description of Support Units

            Description             Manufacturer              Model No.            Serial No.
             Notebook                    IBM                      T30         S/N78-3VMLX 06/01


4.3 Test Location
    All tests were performed at:
    SGS-CSTC Standards Technical Services Co., Ltd., Guangzhou Branch EMC Laboratory,
    198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District,
    Guangzhou, China 510663
    Tel: +86 20 82155555        Fax: +86 20 82075059
    No tests were sub-contracted.


                                                 SGS—CSTC Standards Technical Services Co., Ltd.
                                                 Guangzhou Branch
                                                                                                                       Report No.: GZEM190701430203
                                                                                                                       Page:                      6 of 10


4.4 Test Facility
       The test facility is recognized, certified, or accredited by the following organizations:

       e NVLAP (Lab Code: 200611—0)
       SGS—CSTC Standards Technical Services Co., Ltd., Guangzhou EMC Laboratory is accredited by the
       National Voluntary Laboratory Accreditation Program (NVLAP/NIST). NVLAP Code: 200611—0.
       The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency
       of the Federal Government.

       ©@ ACMA

       SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory can also perform testing for the
       Australian C—Tick mark as a result of our NVLAP accreditation.
       e SGS UK(Certificate No.: 32), SGS—TUV SAARLAND and SGS—FIMKO
       Have approved SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory as a supplier of
       EMC TESTING SERVICES and SAFETY TESTING SERVICES.
       © CNAS (Lab Code: LO167)
       SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been assessed and in
       compliance with CNAS—CLO1:2018 accreditation criteria for testing laboratories (identical to

       ISO/IEC 17025:2017 General Requirements) for the Competence of Testing Laboratories.
       @FCC Recognized 2.948 Listed Test Firm(Registration No.: 282399)
       SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been registered and fully
       described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
       from the FCC is maintained in our files. Registration 282399, May 31, 2002.
       @FCC Recognized Accredited Test Firm(Registration No.: 486818)
       SGS—CSTC Standards Technical Services Co., Ltd., EMC Laboratory has been accredited and fully
       described in a report filed with the (FCC) Federal Communications Commission. The acceptance letter
       from the FCC is maintained in our files. Designation Number: CN5016, Test Firm Registration Number:
       486818, Jul 13, 2017.
       ®e Industry Canada (Registration No.: 4620B, CAB identifier: CNOO052)
        SGS—CSTC Standards Technical Services Co., Ltd., has been registered by Innovation Science and
        Economic Development Canada for Wireless Device Testing laboratories to test to Canadian radio
        equipment requirements. Registration No. 4620B, CAB identifier: CNOO5S2.

       ® VCCI (Registration No.: R—12460, C—12584, G—10449 and T—11179)

       The 10m Semi—anechoic chamber and Shielded Room of SGS—CSTC Standards Technical Services
       Co., Ltd. have been registered in accordance with the Regulations for Voluntary Control Measures with
       Registration No.: R—12460, C—12584, G—10449 and T—11179 respectively.
       ©@ CBTL (Lab Code: TL129)
       SGS—CSTC Standards Technical Services Co., Ltd., E&E Laboratory has been assessed and fully
       comply with the requirements of ISO/IEC 17025:2005, the Basic Rules, IECEE 01 and Rules of
       procedure IECEE 02, and the relevant IECEE CB—Scheme Operational documents.




                                     Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                     overleaf, available on request or accessible at http://www.sqs.com/en/Terms—and—Conditions.aspx and, for electronic format documents,
                                     subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms—and— Conditions/Terms—e—Document. aspx.
                                     Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                                     advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                     Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                                     transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
                                     except in full, without prior written approval of the Company. Any unauthorized alteration, for%ery or falsification of the content or
   #@ifi;lflfl#}flg                      appearance of this document is unlawful and offenders may be prosecuted to the fullest extent         the law. Unless otherwise stated the
    Inspection & Testing Services    results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
  cp@                                Attentlon To check the authenticity of testing /inspection report & certificate, please contact us at telephone: (86—755) 8307 1443,
                                             1: CN.Doccheck@sgs.com
                                    Nn198Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhou, China 510663 t (86—20) 82155555 f (86—20) 82075058 www.sgsgroup.com.cn
                                    ._| PB 7M LZTEKRTAREREMERIIR198SS                                            RB4H: 510663 t (86—20) 82155555 f (86—20) 82075058 sqs.china@sgs.com
                                                                                                                                                      Member of the SGS Group (SGS SA)


                      SGS-CSTC Standards Technical Services Co., Ltd.
                      Guangzhou Branch
                                             Report No.: GZEM190701430203
                                             Page:       7 of 10


4.5 Deviation from Standards
    None
4.6 Abnormalities from Standard Conditions
    None


                             SGS-CSTC Standards Technical Services Co., Ltd.
                             Guangzhou Branch
                                                              Report No.: GZEM190701430203
                                                              Page:       8 of 10


5   Equipment List


    Conducted Peak Output Power
         Equipment             Manufacturer        Model No    Inventory No    Cal Date    Cal Due Date
      EXA Signal Analzer     AgilentTechnologies   N9010A       EMC2138       2018-11-19   2019-11-18
        6dB Attenuator               HP             8491A       EMC2062       2018-04-04   2020-04-03
    Test Software JS1120-3     HangTianXing          V2.6       GZE100-69        N/A           N/A
          MI CABLE                  SGS             0.8M        EMC2136       2017-11-02   2019-11-01
          MI CABLE                  SGS             0.8M        EMC2137       2017-11-02   2019-11-01


                                               SGS—CSTC Standards Technical Services Co., Ltd.
                                               Guangzhou Branch
                                                                                                                      Report No.: GZEM190701430203
                                                                                                                      Page:                       9 of 10



6        Radio Spectrum Technical Requirement

    RF Exposure Compliance Requirement
    The product belongs to standalone portable device base the FCC rule part 2.10918&2.1093. The
    transmission frequencies of the device are between 100 MHz and 6 GHz. The worst case test separation
    distance is 5mm.
    The Max Conducted Output Power and SAR Test Exclusion Threshold (mW) are listed below:


                    Transmit frequency (GHz)                                              Power[dBm]                                   Max Conduc(trio\lN(?utput Power

                                 2.402                                                             1.031                                                       1.268
                                 2.440                                                             1.257                                                       1.336
                                 2.480                                                             1.126                                                       1.296


     The Max Conducted Peak Output Power is 1.257dBm on the highest channel 2.440GHz
     1.257dBm logarithmic terms convert to numeric result is nearly 1.336mW (the maximum power in three
     transmit frequencies)


     According to the formula, calculate the test exclusion thresholds:
     [{max. power of channel, including tune—up tolerance, mW )/
     (min. test separation distance, mm)] +[vf(GHz)]
     General RF Exposure = (1.336mW /5 mm ) x v2.440GHz= 0.42 ® ;
     SAR requirement: S =3.0 @) ;
     0) <@.
     So the SAR report is not required.

     Remark:
     The SAR Test Exclusion Threshold for 100 MHz to 6 GHz is calculated from:
     1) The 1—g and 10—g SAR test exclusion thresholds for 100 MHz to 6 GHz at test separation distances < 50
     mm are determined by:
     [({max. power of channel, including tune—up tolerance, mW)/({min. test separation distance, mm)] —
     [Vf(GHz)] < 3.0 for 1—g SAR and <7.5 for 10—g extremity SAR, where
         f(GHz) is the RF channel transmit frequency in GHz
         Power and distance are rounded to the nearest mW and mm before calculation
          The result is rounded to one decimal place for comparison
     The test exclusions are applicable only when the minimum test separation distance is < 50 mm and for
     transmission frequencies between 100 MHz and 6 GHz. When the minimum test separation distance is < 5
     mm, a distance of 5 mm is applied to determine SAR test exclusion.


     According to SAR Exclusion Threshold in KDB 447498 (DOQ1) General RF Exposure Guidance v06, the SAR
     report is not required.



                                  Unless otherwise agreed in writing, this document is issued by the Company subject to its General Conditions of Service printed
                                  overleaf, available on request or accessible at http://www.sqs.com/en/Terms—and—Conditions.aspx and, for electronic format documents,
                                  subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms—and—Conditions/Terms—e—Document.aspx.
                                  Attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein. Any holder of this document is
                                  advised that information contained hereon reflects the Company‘s findings at the time of its intervention only and within the limits of
                                  Client‘s instructions, if any. The Company‘s sole responsibility is to its Client and this document does not exonerate parties to a
                                  transaction from exercising all their rights and obligations under the transaction documents. This document cannot be reproduced
    PE
     S          #                 except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or falsification of the content or
         trotsil] £)f o           appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law. Unless otherwise stated the
                      rvices      results shown in this test report refer only to the sample(s) tested and such sample(s) are retained for 30 days only.
                           >§'    Attention: To check the authenticity of testing /inspection report & certificate, please contact us at telephone: (86—755) 8307 1443,
                                  or email: CN.Doccheck@sgs.com
                                   No.198 Kezhu Road, Scientech Park, Guangzhou Economic & Technology Development District, Guangzhoy, China 510663 t (86—20) 82155555 f (86—20) 82075058 www.sgsgroup.com.cn
                                 PB —~TSM LZHKARTEERNERRERAKER198S                                              BBZZ: 510663 t (86—20) 82155555 f (86—20) 82075058 sgs.china@sgs.com
                                                                                                                                                      Member of the SGS Group (SGS SA)


                         SGS-CSTC Standards Technical Services Co., Ltd.
                         Guangzhou Branch
                                                            Report No.: GZEM190701430203
                                                            Page:       10 of 10



7   Photographs

7.1 EUT Constructional Details
             Please refer to Appendix A - Photographs of EUT Constructional Details
             for GZEM1907014302CR




                                        --End of Report--