SAR report 02

FCC ID: XRAFB202

Test Report

Download: PDF
FCCID_3510914

Test Laboratory: UL Verification Services Inc. SAR Lab 3                     Date/Time: 6/30/2017 12:06:54 PM

20170630_SystemPerformanceCheck-D2450V2 SN 899

Frequency: 2450 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 2450 MHz; σ = 2.009 S/m; εr = 50.922; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1343; Calibrated: 8/15/2016
- Probe: EX3DV4 - SN3871; ConvF(7.7, 7.7, 7.7); Calibrated: 8/25/2016;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI A v5.0; Type: QD OVA 002 AA; Serial: 1194

Body/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.05 W/kg

Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 60.334 V/m; Power Drift = -0.08 dB
Peak SAR (extrapolated) = 11.0 W/kg
SAR(1 g) = 5.3 W/kg; SAR(10 g) = 2.44 W/kg
Maximum value of SAR (measured) = 7.55 W/kg




                      0 dB = 7.55 W/kg = 8.78 dBW/kg




                                                                                                               Plot No. 1


Test Laboratory: UL Verification Services Inc. SAR Lab 3    Date/Time: 6/30/2017 12:27:23 PM

20170630_SystemPerformanceCheck-D2450V2 SN 899
Frequency: 2450 MHz; Duty Cycle: 1:1

Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 7.23 W/kg




                                                                                           Plot No. 2


Test Laboratory: UL Verification Services Inc., SAR Lab 2                    Date/Time: 7/17/2017 7:46:27 PM

20170717SystemPerformanceCheck-D2450V2 SN 899

Frequency: 2450 MHz; Duty Cycle: 1:1;     Room Ambient Temperature: 24.0C; Liquid Temperature: 23.0C
                                                                                3
Medium parameters used: f = 2450 MHz; σ = 1.945 S/m; εr = 50.224; ρ = 1000 kg/m
DASY5 Configuration:
- Area Scan Setting: Find Secondary Maximum Within: 2.0 dB and with a peak SAR value greater than 0.0012W/kg
- Electronics: DAE4 Sn1433; Calibrated: 3/8/2017
- Probe: EX3DV4 - SN3991; ConvF(7.95, 7.95, 7.95); Calibrated: 5/30/2017;
- Sensor-Surface: 2.5mm (Mechanical Surface Detection)
- Phantom: ELI B v4.0; Type: QDOVA002AA; Serial: 1196

Body/Pin=100 mW/Area Scan (8x8x1): Measurement grid: dx=12mm, dy=12mm
Maximum value of SAR (measured) = 6.63 W/kg

Body/Pin=100 mW/Zoom Scan (7x7x7)/Cube 0: Measurement grid: dx=5mm, dy=5mm, dz=5mm
Reference Value = 45.545 V/m; Power Drift = -0.19 dB
Peak SAR (extrapolated) = 10.5 W/kg
SAR(1 g) = 5.03 W/kg; SAR(10 g) = 2.31 W/kg
Maximum value of SAR (measured) = 7.20 W/kg




                      0 dB = 7.20 W/kg = 8.57 dBW/kg




                                                                                                               Plot No. 3


Test Laboratory: UL Verification Services Inc., SAR Lab 2   Date/Time: 7/17/2017 8:11:01 PM

20170717SystemPerformanceCheck-D2450V2 SN 899
Frequency: 2450 MHz; Duty Cycle: 1:1

Body/Pin=100 mW/Z Scan (1x1x21): Measurement grid: dx=20mm, dy=20mm, dz=5mm
Maximum value of SAR (measured) = 3.95 W/kg




                                                                                              Plot No. 4



Document Created: 2017-07-18 16:49:58
Document Modified: 2017-07-18 16:49:58

© 2025 FCC.report
This site is not affiliated with or endorsed by the FCC