                                 RF EXPOSURE REPORT

                                       REPORT NO.:                    SA140120C32
                                         MODEL NO.:                   IPH-1062
                                                 FCC ID:              2AAWXIPH1062
                                           RECEIVED:                  Jan. 20, 2014
                                                TESTED:               Jan. 21 ~ Jan. 22, 2014
                                                 ISSUED:              Feb. 19, 2014



                            APPLICANT: Incipio Technologies, Inc.

                               ADDRESS: 6001 Oak Canyon, Irvine, CA 92618 USA



                             ISSUED BY: Bureau Veritas Consumer Products Services
                                        (H.K.) Ltd., Taoyuan Branch

                      LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist.,
                                   New Taipei City, Taiwan, R.O.C.

                  TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei
                                 Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C.




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is
permitted only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results
set forth in this report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar
or identical product unless specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon
the information that you provided to us. You have 60 days from date of issuance of this report to notify us of any material error or omission caused by
our negligence, provided, however, that such notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such
issue within the prescribed time shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the
correctness of the report contents. Unless specific mention, the uncertainty of measurement has been explicitly taken into account to declare the
compliance or non-compliance to the specification

 Report No.: SA140120C32                                                  1 of 6                                        Report Format Version 5.0.0


                                         Table of Contents

RELEASE CONTROL RECORD .............................................................................................. 3
1.       CERTIFICATION........................................................................................................... 4
2.       EVALUATION RESULT ................................................................................................. 5
3.       SAR TEST EXCLUSION THRESHOLDS ..................................................................... 6
4.       CONCLUSION .............................................................................................................. 6




Report No.: SA140120C32                                       2 of 6                                  Report Format Version 5.0.0


                           RELEASE CONTROL RECORD

 ISSUE NO.                REASON FOR CHANGE                DATE ISSUED
 SA140120C32              Original release                 Feb. 19, 2014




Report No.: SA140120C32                      3 of 6   Report Format Version 5.0.0


1. CERTIFICATION

            PRODUCT: INCIPIO Focal module
         MODEL NO.: IPH-1062
               BRAND: INCIPIO
          APPLICANT: Incipio Technologies, Inc.
              TESTED: Jan. 21 ~ Jan. 22, 2014
      TEST SAMPLE: ENGINEERING SAMPLE
        STANDARDS: FCC Part 2 (Section 2.1091)
                              FCC OET Bulletin 65, Supplement C (01-01)
                              IEEE C95.1




The above equipment (model: IPH-1062) has been tested by Bureau Veritas

Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found

compliance with the requirement of the above standards. The test record, data

evaluation & Equipment Under Test (EUT) configurations represented herein are

true and accurate accounts of the measurements of the sample’s EMC

characteristics under the conditions specified in this report.




   PREPARED BY            :                                , DATE :   Feb. 19, 2014
                                   Ivy Lin / Specialist

   APPROVED BY            :                                , DATE :   Feb. 19, 2014
                                Ken Liu / Senior Manager




Report No.: SA140120C32                          4 of 6               Report Format Version 5.0.0


2. EVALUATION RESULT

Following FCC KDB 447498 D01 “General SAR test exclusion guidance”

The corresponding SAR Exclusion Threshold condition, listed below:

1) The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at test
   separation distances ≤ 50 mm are determined by:
   [(max. power of channel, including tune-up tolerance, mW)/(min. test separation
   distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for 10-g extremity SAR,16
   where
    f(GHz) is the RF channel transmit frequency in GHz.
    Power and distance are rounded to the nearest mW and mm before
       calculation.
    The result is rounded to one decimal place for comparison The test exclusions
       are applicable only when the minimum test separation distance is ≤ 50 mm
       and for transmission frequencies between 100 MHz and 6 GHz. When the
       minimum test separation distance is < 5 mm, a distance of 5 mm is applied to
       determine SAR test exclusion.

2) At 100 MHz to 6 GHz and for test separation distances > 50 mm, the SAR test
   exclusion threshold is determined according to the following:
   a) [Threshold at 50 mm in step 1) + (test separation distance - 50mm)·( f(MHz)/150)]
      mW, at 100MHz to 1500 MHz
   b) [Threshold at 50 mm in step 1) + (test separation distance - 50 mm)·10] mW at
      > 1500 MHz and ≤ 6 GHz

3) At frequencies below 100 MHz, the following may be considered for SAR test
   exclusion.
   a) The threshold at the corresponding test separation distance at 100 MHz in step
      2) is multiplied by [1 + log(100/f(MHz))] for test separation distances > 50 mm
      and < 200 mm.
   b) The threshold determined by the equation in a) for 50 mm and 100 MHz is
      multiplied by ½ for test separation distances ≤ 50 mm.
   c) SAR measurement procedures are not established below 100 MHz. When SAR
      test exclusion cannot be applied, a KDB inquiry is required to determine SAR
      evaluation requirements for any test results to be acceptable.




Report No.: SA140120C32                  5 of 6                   Report Format Version 5.0.0


3. SAR TEST EXCLUSION THRESHOLDS

Maximum measured transmitter power:
                                                         SAR test
                               Min. test separation                     1-g SAR test
                  Max. Power                             exclusion
    Mode                             distance                             exclusion            Result
                    (mW)                                calculation
                                       (mm)                              thresholds
                                                        value(NOTE 2)

    BT LE            1.245               5                 0.386                3               Pass

NOTE: 1. The antenna type is PCB antenna with 5.3dBi gain.
      2. Calculate SAR test exclusion thresholds from condition “1” formulas.




4. CONCLUSION

Since Source-base time average power is below SAR test exclusion power
thresholds, the SAR evaluation is not required.