Test report

FCC ID: XQPJH051649TX

Test Report

Download: PDF
FCCID_3038319

      TEST REPORT No.: (5216)127-0987(B)

                                              TEST REPORT
To:              NKOK, INC.                                                           To:                                    -
Attn:            Lanny Halim                                                          Attn:                                  -
Address:         5354 Irwindale Ave, Unit A                                           Address:                               -
                 Irwindale, CA 91706
Fax:             626-330-1199                                                         Fax:                                   -
E-mail:          testing@nkok.com                                                     E-mail:                                -
Folder No.:                                                                          --

Factory Name:                                                    --
Location:                                                        --
                                               RealTree Ford F-250 Super Duty: Green
Product:
                                                          MODEL: 82508

                                                                                         Sample No:                                        (5216)127-1066


                                                                                   Date of Receipt:                                          May 09, 2016

                                                                                                                                             May 13, 2016
                                                                                        Test Date(s):                                             to
                                                                                                                                             May 14, 2016

                                                                                     Test Requested:                                   FCC Part 15 – 2012


                                                                                        Test Method:                                   ANSI C63.4 – 2009


                                                                                             FCC ID:                                     XQPJH051649TX


   The results given in this report are related to the tested specimen of the described electrical apparatus.

CONCLUSION: The submitted sample was found to COMPLY with requirement of FCC Part 15 Subpart C.

                                                Authorized Signature:




Reviewed by: Keith Yeung                                              Approved by: Law Man Kit
Date: June 01, 2016                                                   Date: June 01, 2016




BUREAU VERITAS HONG KONG LIMITED –        This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                        of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                 herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                          the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,             includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                         additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                       shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                       shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                 contents.
                                                          Page 1 of 15


     TEST REPORT No.: (5216)127-0987(B)

     Test Result Summary

                                        EMISSION TEST
     Test requirement: FCC Part 15 – 2012
                                                                                                                        Test Result
                    Test Condition                                     Test Method
                                                                                                                     Pass       Failed
     Radiated Emission Test,                                           ANSI C63.4
     9kHz to 1GHz
     Frequency range of Fundamental Emission                           ANSI C63.4
     26dB Bandwidth of Fundamental Emission                            ANSI C63.4
     Duty Cycle Correction During 100mesc                              ANSI C63.4

     Report Revision & Sample Re-submit History:
     --




BUREAU VERITAS HONG KONG LIMITED –    This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                    of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,             herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                      the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,         includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                     additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                   shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                   shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com             contents.
                                                      Page 2 of 15


     TEST REPORT No.: (5216)127-0987(B)
     Test Laboratory & Test Instruments List

     Radiated and Conducted emissions measurements are investigated and taken pursuant to the procedures
     of ANSI C63.4 – 2009. An Open Area Test Site and Full Anechoic Chamber (FCC Listed Site,
     Registration No. 642151) are set up for investigation and located at:

                         BUREAU VERITAS HONG KONG LIMITED, EMC CENTRE
                                                No. 2106-2107, 21/F., Westin Centre,
                                                         26 Hung To Road,
                                                       Kwun Tong, Kowloon,
                                                            Hong Kong


     Test Instrument List
                                                                 Radiated Emission
            EQUIPMENT                  MANUFACTURER                 MODEL NO.                             SERIAL NO.                             CALIBRATION DUE
            EMI TEST RECEIVER          R&S                          ESCI                                  100379                                 22-FEB-2017
            LOOP ANTENNA               ETS LINDGREN                 6502                                  00102266                               05-NOV-2016
            BICONICAL ANTENNA          ROHDE & SCHWARZ              HK116                                 100179                                 13-APR-2018
            LOG-PERIODIC
            DIPOLE ARRAY               ROHDE & SCHWARZ              HL223                                 832369/001                             06-APR-2018
            ANTENNA
            BILOG ANTENNA              SCHAFFNER                    CBL6112D                              25229                                  26-FEB-2018
            OPEN AREA TEST             BVCPS                        N/A                                   N/A
                                                                                                                                                 18-JUN-2016
            SITE
            ANECHOIC CHAMBER           ALBATROSS                    M-CDC                                 80374004499B                           10-MAY-2017
            COAXIAL CABLE              SUHNER                       N/A                                   N/A                                    04-OCT-2016




     Measurement Uncertainty

                  MEASUREMENT                FREQUENCY                UNCERTAINTY
                                             9kHz to 30MHz            4.2dB
                                             30MHz to 1GHz            5.0dB
                  Radiated emissions
                                             1GHz to 18GHz            4.9dB
                                             18GHz to 40GHz           4.8dB

     Remarks:-
     N/A : Not Applicable or Not Available

     The measurement instrumentation uncertainty would be taking into consideration on each of the test result




BUREAU VERITAS HONG KONG LIMITED –                     This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                                     of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                              herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                                       the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,                          includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                                      additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                                    shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                                    shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                              contents.
                                                                       Page 3 of 15


     TEST REPORT No.: (5216)127-0987(B)

      Equipment Under Test [EUT]
      Description of Sample:
      Model Name:                      RealTree Ford F-250 Super Duty: Green
      Model Number:                    82508
      Additional Model Name:           --
      Additional Model Number:         --
      Additional Model information:    --
      Rating:                          3Vd.c. (“AA” size battery x 2)


      Description of EUT Operation:
      The Equipment Under Test (EUT) is a NKOK, INC. of Radio Control toy. The transmitter is 2 sticks
      and operating at 49.86MHz. The EUT continues to transmit while sticks are being pushed or pulled,
      Modulation by IC, and type is pulse modulation.
      The transmitter has different control:
          1. Left stick – control forward and backward
          2. Right stick – control left and right

      Antenna Requirement (Section 15.203)
      The EUT is use of a permanently antenna. The antenna consists of 35cm long wire. It is soldered
      on the PCB. The antenna is not replaceable or user serviceable. The requirements of S15.203 are
      met. There are no deviations or exceptions to the specifications.

                                            Photo of Antenna




BUREAU VERITAS HONG KONG LIMITED –       This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                       of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                         the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,            includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                        additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                      shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                      shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                contents.
                                                         Page 4 of 15


     TEST REPORT No.: (5216)127-0987(B)

      Test Results
      Radiated Emissions (Fundamental)
      Test Requirement:           FCC Part 15 Section 15.235
      Test Method:                ANSI C63.4
      Test Date(s):               2016-05-14
      Temperature:                29.0 oC
      Humidity:                   68.0 %
      Atmospheric Pressure:       100.5 kPa
      Mode of Operation:          Transmission mode
      Tested Voltage:             3Vd.c. (“AA” size battery x 2)

     Test Method:
     Radiated emissions measurements are investigated and taken pursuant to the procedures of ANSI C63.4 – 2009.

     The equipment under test (EUT) was placed on a non-conductive turntable with dimensions of 1.5m x 1m and 0.8m
     high above the ground. 3m from the EUT, a broadband antenna mounting on the mast received the signal strength.
     During the test, each emission was maximized by: having the EUT continuously working, investigated all operating
     modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating
     interconnecting cables, For battery operated equipment, the equipment tests shall be perform using new battery. The
     turntable was rotated to maximize the emission level. The antenna was then moving along the mast from 1m up to
     4m until no more higher value was found. Both horizontal and vertical polarization of the antenna were placed and
     investigated.

     For below 30MHz, a loop antenna with its vertical plane is place 3m from the EUT and rotated about its vertical axis
     for maximum response at each azimuth about the EUT. And the centre of the loop shall be 1m above the ground.

     Location: The Roof, Westin Centre, 26 Hung To Road, Kwun Tong, Kowloon, Hong Kong

     Test Setup: Open Area Test Site




                                      Antenna                  Measuring
                                      Mast                     Antenna                                      Turntable




                                                                             3 meter

                           Receiver




BUREAU VERITAS HONG KONG LIMITED –              This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                              of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                       herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                                the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,                   includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                               additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                             shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                             shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                       contents.
                                                                Page 5 of 15


     TEST REPORT No.: (5216)127-0987(B)
     Limits for Field Strength of Fundamental Emissions [FCC 47CFR 15.235]:
             Frequency Range of                     Field Strength of                                              Field Strength of
                Fundamental                       Fundamental Emission                                           Fundamental Emission
                                                         [Peak]                                                        [Average]
                   [MHz]                                 [µV/m]                                                          [µV/m]
               49.82 – 49.90                      100,000 (100 dBµV/m)                                            10,000 (80 dBµV/m)

     Measurement Data

     Test Result of (Transmission mode): PASS

     Detection mode: Peak
      Frequency          Polarity        Antenna        Field Strength Limit at 3m                                       Margin
        (MHz)             (H/V)         Factor and          at 3m       (dBµV/m)                                          (dB)
                           and          Cable Loss        (dBµV/m)
                         degree           (dB/m)
        49.862              H              10.0                   64.3                        100.0                        -35.7
        49.862              V              10.0                   55.8                        100.0                        -44.2


     Detection mode: #Average
      Frequency          Polarity        Antenna        Field Strength Limit at 3m                                       Margin
        (MHz)             (H/V)         Factor and          at 3m       (dBµV/m)                                          (dB)
                           and          Cable Loss        (dBµV/m)
                         degree           (dB/m)
        49.862              H              10.0                 **60.9                         80.0                        -19.1
        49.862              V              10.0                 **52.4                         80.0                        -27.6

     # For pulse modulated devices and using measuring equipment employing a peak detection
     mode, properly adjusted for such factor as pulse desensitisation.
     **Duty Cycle Correction = 20Log(0.676) = -3.4dB

     Note:   Field Strength includes Antenna Factor and Cable Loss.

     Receiver setting:    RBW       =   100KHz
                          VBW       =   300KHz




BUREAU VERITAS HONG KONG LIMITED –                   This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                                   of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                            herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                                     the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,                        includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                                    additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                                  shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                                  shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                            contents.
                                                                     Page 6 of 15


     TEST REPORT No.: (5216)127-0987(B)
      Radiated Emissions (9kHz – 1GHz)
      Test Requirement:        FCC Part 15 Section 15.209
      Test Method:             ANSI C63.4
      Test Date(s):            2016-05-14
                                       o
      Temperature:             29.0 C
      Humidity:                68.0 %
      Atmospheric Pressure:    100.5 kPa
      Mode of Operation:       Transmission mode
      Tested Voltage:          3Vd.c. (“AA” size battery x 2)

     Limits for Radiated Emissions [FCC 47 CFR 15.209]:
          Frequency Range                   Quasi-Peak Limits                                        Measurement Distance
               [MHz]                             [µV/m]                                                      m
              0.009-0.490                           2400/F(kHz)                                                             300
              0.490-1.705                          24000/F(kHz)                                                              30
                1.705-30                                30                                                                   30
                 30-88                                 100                                                                    3
                 88-216                                150                                                                    3
                216-960                                200                                                                    3
               Above960                                500                                                                    3

     Measurement Data

     Test Result of (Transmission mode): PASS

     Detection mode: Quasi-Peak

                                              Field
                            Polarity
           Frequency                        Strength                            Limit                  Margin (dB)
                             (H/V)

            Emissions detected are more than 20 dB below the limit line(s) in
                                   9kHz to 30MHz




BUREAU VERITAS HONG KONG LIMITED –         This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                         of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                  herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                           the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,              includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                          additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                        shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                        shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                  contents.
                                                           Page 7 of 15


     TEST REPORT No.: (5216)127-0987(B)
     Measurement Data
     Test Result of (Transmission mode): PASS

     Detection mode: Quasi-Peak
                                        Antenna Factor Field Strength Limit at 3m
      Frequency          Polarity                                                                                                 Margin
                                        and Cable Loss
        (MHz)             (H/V)
                                            (dB/m)     at 3m (dBµV/m) (dBµV/m)                                                     (dB)
        99.724              H                11.7           35.8         43.5                                                       -7.7
       149.586              H                10.5           32.5         43.5                                                      -11.0
       199.448              H                 9.9           35.1         43.5                                                       -8.4
       249.310              H                13.0           36.7         46.0                                                       -9.3
       299.172              H                13.8           39.5         46.0                                                       -6.5
       349.034              H                15.7           43.5         46.0                                                       -2.5
       398.896              H                17.5           32.6         46.0                                                      -13.4
       448.758              H                18.1           31.9         46.0                                                      -14.1
       498.620              H                19.2           32.5         46.0                                                      -13.5
       548.482              H                20.2           33.6         46.0                                                      -12.4


                                        Antenna Factor Field Strength Limit at 3m
      Frequency          Polarity                                                                                                 Margin
                                        and Cable Loss
        (MHz)             (H/V)
                                            (dB/m)     at 3m (dBµV/m) (dBµV/m)                                                     (dB)
        99.724              V                11.7           35.3         43.5                                                       -8.2
       149.586              V                10.5           38.3         43.5                                                       -5.2
       199.448              V                 9.9           35.8         43.5                                                       -7.7
       249.310              V                13.0           31.8         46.0                                                      -14.2
       299.172              V                13.8           38.2         46.0                                                       -7.8
       349.034              V                15.7           40.6         46.0                                                       -5.4
       398.896              V                17.5           34.6         46.0                                                      -11.4
       448.758              V                18.1           32.6         46.0                                                      -13.4
       498.620              V                19.2           33.3         46.0                                                      -12.7
       548.482              V                20.2           34.7         46.0                                                      -11.3



     Note:   Field Strength includes Antenna Factor and Cable Loss.

     Receiver setting:    RBW       =   120KHz
                          VBW       =   120KHz




BUREAU VERITAS HONG KONG LIMITED –                 This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                                 of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                          herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                                   the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,                      includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                                  additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                                shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                                shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                          contents.
                                                                   Page 8 of 15


     TEST REPORT No.: (5216)127-0987(B)
      26dB Bandwidth of Fundamental Emission
      Test Requirement:          FCC 47 CFR 15.235
      Test Method:               ANSI C63.4
      Test Date(s):              2016-05-13
                                      o
      Temperature:               29.0 C
      Humidity:                  68.0 %
      Atmospheric Pressure:      100.5 kPa
      Mode of Operation:         Transmission mode
      Tested Voltage:            3Vd.c. (“AA” size battery x 2)

      Test Method:
      The bandwidth is measured at an amplitude level reduced from the reference level by a
      specified ratio. The reference level is the level of the highest amplitude signal observed from
      the transmitter at the fundamental frequency. Once the reference level is established, the
      equipment is conditioned with typical modulating signal to produce the worst-case (i.e. the
      widest) bandwidth.




      Limits for 26dB Bandwidth of Fundamental Emission:
               Frequency                      26dB Bandwidth                                                       Limits
                 [MHz]                            [KHz]                                                            [MHz]
                49.8616                            28.8                                                     within 49.82-49.90




BUREAU VERITAS HONG KONG LIMITED –         This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                         of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                  herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                           the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,              includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                          additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                        shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                        shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                  contents.
                                                           Page 9 of 15


     TEST REPORT No.: (5216)127-0987(B)
     Measurement Data

     Test Result of 26dB Bandwidth of Fundamental Emission: PASS




BUREAU VERITAS HONG KONG LIMITED –   This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                   of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,            herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                     the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,        includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                    additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                  shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                  shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com            contents.
                                                    Page 10 of 15


     TEST REPORT No.: (5216)127-0987(B)
      Duty Cycle Correction During 100msec:

      Each function key sends a different series of characters, but each packet period (100msec)
      never exceeds a series of 22 long (1.6msec) and 54 short (0.6msec) pulses. Assuming any
      combination of short and long pulses maybe obtained due to encoding the worst case
      transmit duty cycle would be considered (22 x 1.6msec)+(54 x 0.6msec) per 100msec =
      67.6% duty cycle.


      Remarks: -

      Duty Cycle Correction = 20Log(0.676) = -3.4dB
      Therefore, -20dB is taken


      The following figures [Figure A to Figure B] show the characteristics of the pulse train for one
      of these functions.




BUREAU VERITAS HONG KONG LIMITED –         This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                         of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                  herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                           the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,              includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                          additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                        shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                        shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                  contents.
                                                          Page 11 of 15


     TEST REPORT No.: (5216)127-0987(B)

                                       Figure A [Long Pulse]




                                      Figure B [Short Pulse]




BUREAU VERITAS HONG KONG LIMITED –   This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                   of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,            herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                     the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,        includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                    additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                  shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                  shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com            contents.
                                                    Page 12 of 15


     TEST REPORT No.: (5216)127-0987(B)

     Photographs of EUT

            Front View of the product                                       Rear View of the product




             Top View of the product                                     Bottom View of the product




             Side View of the product                                        Side View of the product




               Battery compartment                                                        Battery Cover




BUREAU VERITAS HONG KONG LIMITED –      This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                      of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,               herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                        the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,           includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                       additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                     shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                     shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com               contents.
                                                       Page 13 of 15


     TEST REPORT No.: (5216)127-0987(B)
     Photographs of EUT

           Internal View of the product                                 Internal View of the product




              Inner Circuit Top View                                      Inner Circuit Bottom View




                      Antenna




BUREAU VERITAS HONG KONG LIMITED –     This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                     of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,              herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                       the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,          includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                      additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                    shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                    shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com              contents.
                                                      Page 14 of 15


     TEST REPORT No.: (5216)127-0987(B)
                         Measurement of Radiated Emission Test Set Up




                                     ***** End of Report *****




BUREAU VERITAS HONG KONG LIMITED –   This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                   of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,            herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                     the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,        includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                    additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                  shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                  shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com            contents.
                                                    Page 15 of 15



Document Created: 2019-11-11 01:17:59
Document Modified: 2019-11-11 01:17:59

© 2025 FCC.report