Test Report

FCC ID: XQPFTB071027TX

Test Report

Download: PDF
FCCID_1324409

                                                               BUREAU
                                                               VERITAS


       TEST REPORT No.: (5210)166-0896


                                        TEST REPORT
To:              NKOK, INC.                                                              To:
Attn:            Lanny Halim                                                             Attn:
Address:         13668 E Valley Blvd G2 City of Industry CA                              Address:
                 91746
Fax:             6263301199                                                               Fax:
E-mail:          kohsche   nkok.com / lann          nkok.com                              E-mail:
Folder No.:                                                     BVCK1 OJU331 MTHS-B

Factory name:
Location:

Product:


                                                                                             Sample No:                                      (5210)166-0896


                                                                                                                                                 July 3,2010
                                                                                               Test date:                                             To
                                                                                                                                                 July 5,2010


                                                                                        Test Requested:                                   FCC Part 15 - 2008



                                                                                           Test Method:                                   ANSI C63.4 - 2003



                                                                                                 FCC 10:                                 XQPFTB071027TX


   The results given in this report are related to the tested specimen of the described electrical apparatus.

CONCLUSION: The submitted      sample was found to COMPLY with requirement                                                   of FCC Part 15 Subpart C.

                                                   Authorized Signature:




BUREAU VERITAS HONG KONG LlMITED-            This report is intended for your exclusive use Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                           of our name or trademark, is permitted only with our prior written permission Our report is limited to the test samples identified
                                             herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
1/F Pacific Trade Centre,
                                             the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,                includes all of the tests requested by you and the results thereof You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                            additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +8522331 0888                           shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +8522331 0889                           shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                    contents.
                                                              Page 1 of 13


     TEST REPORT No.: (5210)166-0896

     Location of the test laboratory

     Radiated and Conducted emissions measurements are investigated and taken pursuant to the procedures
     of ANSI C63.4 – 2003. An Open Area Test Site and Full Anechoic Chamber (FCC Listed Site,
     Registration No. 642151) are set up for investigation and located at :

                             BUREAU VERITAS HONG KONG LIMITED, EMC CENTRE
                                     No. 2106-2107, 21/F., Westin Centre,
                                              26 Hung To Road,
                                            Kwun Tong, Kowloon,
                                                 Hong Kong



     List of measuring equipment

                                                             Radiated Emission
            EQUIPMENT               MANUFACTURER                MODEL NO.                             SERIAL NO.                             CALIBRATION DUE
            EMI TEST RECEIVER       R&S                         ESCI                                  100379                                 24-AUG-2010
            LOOP ANTENNA            ETS-LINDGREN                6502                                  00102266                               17-MAY-2011
            BILOG ANTENNA           SCHAFFNER                   CBL6112D                              25229                                  30-MAY-2011
            OPEN AREA TEST          BVCPS                       N/A                                   N/A                                    06-JULY-2011
            SITE
            ANECHOIC CHAMBER        ALBATROSS                   M-CDC                                 80374004499B                           08-JULY-2011
            COAXIAL CABLE           SUHNER                      N/A                                   N/A                                    26-OCT-2010
            SPECTRUM                ADVANTEST                   R3127                                 111000909                              17-DEC-2010
            ANALYZER




     Remarks:-
     N/A : Not Applicable or Not Available

     The measurement instrumentation uncertainty would be taking into consideration on each of the test result




BUREAU VERITAS HONG KONG LIMITED –                 This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                                 of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                          herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                                   the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,                      includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                                  additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                                shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                                shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                          contents.
                                                                   Page 2 of 13


     TEST REPORT No.: (5210)166-0896

     Equipment Under Test [EUT]
     Description of Sample:
     Model Name:      My First R/C Vehicle
     Model Number: 80051
     Rating:          9Vd.c. (“6F22” size battery x 1)


     Description of EUT Operation:
     The Equipment Under Test (EUT) is a NKOK, INC. of Radio Control toy. It is 2 buttons
     and 1 switch transmitter and operating at 27.146MHz. The EUT continues to transmit
     buttons is being pressed, Modulation by IC, and type is pulse modulation.
     The transmitter has different control:
         1. Left button – Forward control
         2. Right button – Turing control
         3. Switch “ON/OFF” – ON/OFF control

     Antenna Requirement (Section 15.203)
     The EUT is use of a permanently antenna. The antenna consists of 17cm long metal
     spring covered with rubber. It is soldered on the PCB. The antenna is not replaceable or
     user serviceable. The requirements of S15.203 are met. There are no deviations or
     exceptions to the specifications.

                                        Photo of Antenna




BUREAU VERITAS HONG KONG LIMITED –    This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                    of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,             herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                      the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,         includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                     additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                   shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                   shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com             contents.
                                                      Page 3 of 13


     TEST REPORT No.: (5210)166-0896

     Test Results
     Radiated Emissions (Fundamental)

     Test Requirement:            FCC Part 15 Section 15.227
     Test Method:                 ANSI C63.4
     Test Date(s):                2010-07-05
     Temperature:                 32.0 oC
     Humidity:                    65.0 %
     Atmospheric Pressure:        100.6 kPa
     Mode of Operation:           Transmission mode
     Tested Voltage:              9Vd.c. (“6F22” size battery x 1)

     Test Method:

     Radiated emissions measurements are investigated and taken pursuant to the procedures of ANSI C63.4 – 2003.

     The equipment under test (EUT) was placed on a non-conductive turntable with dimensions of 1.5m x 1m and 0.8m
     high above the ground. 3m from the EUT, a broadband antenna mounting on the mast received the signal strength.
     During the test, each emission was maximized by: having the EUT continuously working, investigated all operating
     modes, rotated about all 3 axis (X, Y & Z) and considered typical configuration to obtain worst position, manipulating
     interconnecting cables, For battery operated equipment, the equipment tests shall be perform using new battery. The
     turntable was rotated to maximize the emission level. The antenna was then moving along the mast from 1m up to
     4m until no more higher value was found. Both horizontal and vertical polarization of the antenna were placed and
     investigated.

     For below 30MHz, a loop antenna with its vertical plane is place 3m from the EUT and rotated about its vertical axis
     for maximum response at each azimuth about the EUT. And the centre of the loop shall be 1m above the ground.

     Location: The Roof, Westin Centre, 26 Hung To Road, Kwun Tong, Kowloon, Hong Kong

     Test Setup: Open Area Test Site




                                      Antenna                  Measuring
                                      Mast                     Antenna                                      Turntable




                                                                             3 meter

                           Receiver




BUREAU VERITAS HONG KONG LIMITED –              This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                              of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                       herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                                the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,                   includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                               additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                             shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                             shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                       contents.
                                                                Page 4 of 13


     TEST REPORT No.: (5210)166-0896
        Limits for Field Strength of Fundamental Emissions [FCC 47CFR 15.227]:
            Frequency Range of                Field Strength of                                               Field Strength of
               Fundamental                  Fundamental Emission                                            Fundamental Emission
                                                   [Peak]                                                         [Average]
                     [MHz]                         [µV/m]                                                           [µV/m]
                 26.96 – 27.28                100,000 (100 dBµV/m)                                               10,000 (80 dBµV/m)

        Measurement Data

        Test Result of (Transmission mode): PASS

        Detection mode: Peak
         Frequency    Polarity     Antenna            Field Strength Limit at 3m                                      Margin
           (MHz)       (H/V)      Factor and              at 3m       (dBµV/m)                                         (dB)
                        and       Cable Loss            (dBµV/m)
                      degree        (dB/m)
          27.146        V/0°          9.9                      54.0                         100                        -46.0

        Detection mode: # Average
         Frequency    Polarity     Antenna            Field Strength Limit at 3m                                      Margin
           (MHz)       (H/V)      Factor and              at 3m       (dBµV/m)                                         (dB)
                        and       Cable Loss            (dBµV/m)
                      degree        (dB/m)
          27.146        V/0°          9.9                    **51.5                           80                       -28.5


        # For pulse modulated devices and using measuring equipment employing a peak
        detection mode, properly adjusted for such factor as pulse desensitisation.
        **Duty Cycle Correction = 20Log(0.754) =-2.5dB

        Note: Field Strength includes Antenna Factor and Cable Loss.

        Receiver setting: RBW = 100KHz
                          VBW = 300KHz




BUREAU VERITAS HONG KONG LIMITED –          This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                          of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                   herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                            the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,               includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                           additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                         shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                         shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                   contents.
                                                            Page 5 of 13


     TEST REPORT No.: (5210)166-0896

     Radiated Emissions (9kHz – 1GHz)
     Test Requirement:          FCC Part 15 Section 15.209
     Test Method:               ANSI C63.4
     Test Date(s):              2010-07-05
     Temperature:               32.0 oC
     Humidity:                  65.0 %
     Atmospheric Pressure:      100.6 kPa
     Mode of Operation:         Transmission mode
     Tested Voltage:            9Vd.c. (“6F22” size battery x 1)

     Limits for Radiated Emissions [FCC 47 CFR 15.209]:
                    Frequency Range                                                              Quasi-Peak Limits
                          [MHz]                                                                       [µV/m]
                           1.705-30                                                                             300
                             30-88                                                                              100
                             88-216                                                                             150
                            216-960                                                                             200
                           Above960                                                                             500

     Measurement Data
     Test Result of (Transmission mode): PASS

     Detection mode: Quasi-Peak
                               Antenna Factor Field Strength Limit at 3m
      Frequency     Polarity                                                                                                Margin
                               and Cable Loss
        (MHz)        (H/V)                    at 3m (dBµV/m) (dBµV/m)                                                        (dB)
                                   (dB/m)
       162.876         H              12.7                      24.3                           43.5                          -19.2
       190.022         H              12.4                      27.3                           43.5                          -16.2
       217.168         H              15.1                      26.7                           46.0                          -19.3
       244.314         H              13.7                      28.7                           46.0                          -17.3
       271.460         H              13.9                      38.6                           46.0                           -7.4
       298.606         H              15.3                      40.3                           46.0                           -5.7
       325.760         H              17.3                      41.7                           46.0                           -4.3
       352.880         H              18.0                      41.4                           46.0                           -4.6
       380.040         H              18.2                      40.6                           46.0                           -5.4
       407.200         H              19.5                      39.2                           46.0                           -6.8
       434.340         V              18.9                      39.8                           46.0                           -6.2
       461.480         V              19.5                      38.6                           46.0                           -7.4

     Note: Field Strength includes Antenna Factor and Cable Loss.

     Receiver setting: RBW = 120KHz
                       VBW = 120KHz


BUREAU VERITAS HONG KONG LIMITED –           This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                           of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                    herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                             the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,                includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                            additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                          shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                          shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                    contents.
                                                             Page 6 of 13


     TEST REPORT No.: (5210)166-0896

     26dB Bandwidth of Fundamental Emission

     Test Requirement:            FCC 47 CFR 15.227
     Test Method:                 ANSI C63.4:2003 (Section 13.1.7)
     Test Date(s):                2010-07-03
     Temperature:                 24.0 oC
     Humidity:                    65.0 %
     Atmospheric Pressure:        101.3 kPa
     Mode of Operation:           Transmission mode
     Tested Voltage:              9Vd.c. (“6F22” size battery x 1)

     Test Method:

     The bandwidth is measured at an amplitude level reduced from the reference level by a specified ratio.
     The reference level is the level of the highest amplitude signal observed from the transmitter at the
     fundamental frequency. Once the reference level is established, the equipment is conditioned with
     typical modulating signal to produce the worst-case (i.e. the widest) bandwidth.




     Limits for 26dB Bandwidth of Fundamental Emission:
               Frequency                       26dB Bandwidth                                                     Limits
                 [MHz]                             [KHz]                                                          [MHz]
               27.14624                            91.52                                                  within 26.96 – 27.28




BUREAU VERITAS HONG KONG LIMITED –            This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                            of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,                     herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                              the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,                 includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                             additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                           shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                           shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com                     contents.
                                                              Page 7 of 13


     TEST REPORT No.: (5210)166-0896

     Measurement Data :

     Test Result of 26dB Bandwidth of Fundamental Emission: PASS




BUREAU VERITAS HONG KONG LIMITED –   This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                   of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,            herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                     the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,        includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                    additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                  shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                  shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com            contents.
                                                     Page 8 of 13


     TEST REPORT No.: (5210)166-0896


     Duty Cycle Correction During 100msec:

     Each function key sends a different series of characters, but each packet period
     (49.2msec) never exceeds a series of 53 (0.7msec) pulses. Assuming any
     combination of pulses may be obtained due to encoding the worst case transmit duty
     cycle would be considered (53x0.7msec) per 49.2msec=75.4% duty cycle. Figure A
     through B show the characteristics of the pulse train for one of these functions.


     Remarks:

     Duty Cycle Correction = 20Log(0.754) =-2.5dB



     The following figures [Figure A to Figure B] show the characteristics of the pulse
     train for one of these functions.




BUREAU VERITAS HONG KONG LIMITED –   This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                   of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,            herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                     the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,        includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                    additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                  shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                  shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com            contents.
                                                     Page 9 of 13


     TEST REPORT No.: (5210)166-0896

                                       Figure A [Pulse Train]




                                     Figure B [Single Pulse]




BUREAU VERITAS HONG KONG LIMITED –   This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                   of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,            herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                     the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,        includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                    additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                  shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                  shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com            contents.
                                                    Page 10 of 13


     TEST REPORT No.: (5210)166-0896

     Photographs of EUT

            Front View of the product                                      Rear View of the product




              Inner Circuit Top View                                      Inner Circuit Bottom View




BUREAU VERITAS HONG KONG LIMITED –     This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                     of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,              herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                       the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,          includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                      additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                    shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                    shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com              contents.
                                                      Page 11 of 13


     TEST REPORT No.: (5210)166-0896

               Battery compartment                                                     Battery Cover




       Front View of the product (Internal)                   Rear View of the product (Internal)




                      Antenna




BUREAU VERITAS HONG KONG LIMITED –   This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                   of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,            herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                     the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,        includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                    additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                  shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                  shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com            contents.
                                                    Page 12 of 13


     TEST REPORT No.: (5210)166-0896

                            Measurement of Radiated Emission Test Set Up




                                      ***** End of Report *****




BUREAU VERITAS HONG KONG LIMITED –    This report is intended for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use
Kowloon Bay Office                    of our name or trademark, is permitted only with our prior written permission. Our report is limited to the test samples identified
1/F Pacific Trade Centre,             herein. The results set forth in this report are not necessarily indicative or representative of the statistical quality or characteristics of
                                      the lot from which a test sample was taken or any similar or identical product unless specifically and expressly noted. Our report
2 Kai Hing Road, Kowloon Bay,         includes all of the tests requested by you and the results thereof. You shall have thirty days from receipt of this report to request
Kowloon,HONG KONG                     additional testing of the samples or to notify us of any errors or omissions relating to our report, provided, however, such notice
Tel: +852 2331 0888                   shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time
Fax: +852 2331 0889                   shall constitute your unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report
www.cps.bureauveritas.com             contents.
                                                     Page 13 of 13



Document Created: 2010-07-19 21:30:44
Document Modified: 2010-07-19 21:30:44

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC