12446338-E1V1 FCCIC Report 15.231

FCC ID: XQC-WST212

Test Report

Download: PDF
FCCID_3974872

CERTIFICATION C2PC TEST REPORT
               Report Number. : 12446338-E1V1
      Applicant :    ECOLINK INTELLIGENT TECHNOLOGY, INC.
                     2055 CORTE DEL NOGAL
                     CARLSBAD, CA, 92011, U.S.A

         FCC ID :    XQC-WST212

           ISED :    9863B-WST212

 Model Number :      CS-202

EUT Description :    Wireless Security Door/Window Sensor

Test Standard(s) :   FCC 47 CFR PART 15 SUBPART C
                     INDUSTRY CANADA RSS 210



                            Date Of Issue:
                            August 16, 2018

                            Prepared by:
                      UL Verification Services Inc.
                         47173 Benicia Street
                      Fremont, CA 94538 U.S.A.
                         TEL: (510) 771-1000
                         FAX: (510) 661-0888




                     NVLAP LAB CODE 200065-0


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212

                                                 Revision History

            Issue
 Rev.       Date                Revisions                                                               Revised By
  V1        8/16/18             Initial Issue                                                                   -




                                     Page 2 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                              DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                                         IC: 9863B-WST212

                                             TABLE OF CONTENTS
1.     ATTESTATION OF TEST RESULTS ................................................................................. 4

2.     TEST METHODOLOGY ..................................................................................................... 5

3.     FACILITIES AND ACCREDITATION ................................................................................. 5

4.     CALIBRATION AND UNCERTAINTY ................................................................................ 6
     4.1.    MEASURING INSTRUMENT CALIBRATION .............................................................. 6
     4.2.    SAMPLE CALCULATION ............................................................................................ 6
     4.3.    MEASUREMENT UNCERTAINTY ............................................................................... 6

5.     EQUIPMENT UNDER TEST ............................................................................................... 7
     5.1.    DESCRIPTION OF EUT .............................................................................................. 7
     5.2.    DESCRIPTION OF CLASS II PERMISSIVE CHANGE ................................................ 7
     5.3.    MAXIMUM OUTPUT POWER...................................................................................... 7
     5.4.    DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 7
     5.5.    SOFTWARE AND FIRMWARE .................................................................................... 7
     5.6.    WORST-CASE CONFIGURATION AND MODE .......................................................... 7
     5.7.    DESCRIPTION OF TEST SETUP ................................................................................ 8

6.     TEST AND MEASUREMENT EQUIPMENT ....................................................................... 9

7.     ANTENNA PORT TEST RESULTS ...................................................................................10
     7.1.    DUTY CYCLE .............................................................................................................10

8.     RADIATED EMISSION TEST RESULTS...........................................................................14

9.     SETUP PHOTOS ...............................................................................................................23




                                     Page 3 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                                        FAX: (510) 661-0888
      This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212


1. ATTESTATION OF TEST RESULTS
COMPANY NAME:                       ECOLINK INTELLIGENT TECHNOLOGY, INC.
                                    2055 CORTE DEL NOGAL
                                    CARLSBAD, CA, 92011, U.S.A

EUT DESCRIPTION:                    WIRELESS SENSOR

MODEL:                              CS-202

SERIAL NUMBER:                      782136724608

DATE TESTED:                        AUGUST 07, 2018 TO AUGUST 10, 2018

                                         APPLICABLE STANDARDS
                              STANDARD                                                  TEST RESULTS
                      FCC PART 15 SUBPART C                                                    Pass
          INDUSTRY CANADA RSS-210 Issue 9, Annex A                                             Pass
               INDUSTRY CANADA RSS-GEN Issue 5                                                 Pass


UL Verification Services Inc tested the above equipment in accordance with the requirements
set forth in the above standards. All indications of Pass/Fail in this report are opinions
expressed by UL Verification Services Inc. based on interpretations and/or observations of test
results. Measurement Uncertainties were not taken into account and are published for
informational purposes only. The test results show that the equipment tested is capable of
demonstrating compliance with the requirements as documented in this report.

Note: The results documented in this report apply only to the tested sample, under the
conditions and modes of operation as described herein. This document may not be altered or
revised in any way unless done so by UL Verification Services Inc. and all revisions are duly
noted in the revisions section. Any alteration of this document not carried out by UL Verification
Services Inc will constitute fraud and shall nullify the document. This report must not be used
by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any
agency of the Federal Government, or any agency of the U.S. government.

Approved & Released For
UL Verification Services Inc. By:                                Reviewed By:




Dan Coronia                                                     Kiya Kedida
CONSUMER TECHNOLOGY DIVISION                                    CONSUMER TECHNOLOGY DIVISION
Operations Leader                                               Project Engineer
UL Verification Services Inc.                                   UL Verification Services Inc.


                                     Page 4 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212


2. TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.10-2013,
FCC CFR 47 Part 2, FCC CFR 47 Part 15, RSS-GEN Issue 5, and RSS-210 Issue 9.

3. FACILITIES AND ACCREDITATION
The test sites and measurement facilities used to collect data are located at 47173 and 47266
Benicia Street, Fremont, California, USA. Line conducted emissions are measured only at the
47173 address. The following table identifies which facilities were utilized for radiated emission
measurements documented in this report. Specific facilities are also identified in the test results
sections.

                     47173 Benicia Street                           47266 Benicia Street
                   Chamber A(ISED: 2324B-1)                        Chamber D(ISED: 22541-1)
                   Chamber B(ISED: 2324B-2)                        Chamber E(ISED: 22541-2)
                   Chamber C(ISED: 2324B-3)                        Chamber F(ISED: 22541-3)
                                                                   Chamber G(ISED: 22541-4)
                                                                   Chamber H(ISED: 22541-5)

The above test sites and facilities are covered under FCC Test Firm Registration # 208313.
Chambers A through C are covered under ISED company address code 2324B with site
numbers 2324B -1 through 2324B-3, respectively. Chambers D through H are covered under
Industry Canada company address code 22541 with site numbers 22541 -1 through 22541-5,
respectively.

UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0.




                                     Page 5 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212


4. CALIBRATION AND UNCERTAINTY
   4.1.          MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been
calibrated in accordance with the manufacturer's recommendations, and is traceable to
recognized national standards.


   4.2.          SAMPLE CALCULATION

Where relevant, the following sample calculation is provided:
      Field Strength (dBuV/m) = Measured Voltage (dBuV) + Antenna Factor (dB/m) +
      Cable Loss (dB) – Preamp Gain (dB)
      36.5 dBuV + 18.7 dB/m + 0.6 dB – 26.9 dB = 28.9 dBuV/m


   4.3.          MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for tests
performed on the apparatus:

                                Parameter                                        Uncertainty

      Worst Case Radiated Disturbance, 9kHz to 30 MHz                            3.15 dB
      Worst Case Radiated Disturbance, 30 to 1000 MHz                            5.36 dB
      Worst Case Radiated Disturbance, 1000 to 18000 MHz                         4.32 dB
      Worst Case Radiated Disturbance, 18000 to 26000 MHz                        4.45 dB
      Worst Case Radiated Disturbance, 26000 to 40000 MHz                        5.24 dB

Uncertainty figures are valid to a confidence level of 95%.




                                     Page 6 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212


5. EQUIPMENT UNDER TEST

   5.1.          DESCRIPTION OF EUT
The EUT is a battery powered wireless transmitter for home automation/security application.

   5.2.          DESCRIPTION OF CLASS II PERMISSIVE CHANGE
The major change filed under this application is:

   •    New Model number (CS-202) and new Firmware which results in increased duty cycle.
   •    Modified Enclosure, removed rubber bottom.
   •    Removed switch, SW2, changed to no place.

   5.3.          MAXIMUM OUTPUT POWER

The transmitter has the maximum peak and average radiated field strengths as follows:

   Frequency                    Mode               Field Strength Field Strength
     Range                                              Peak         Average
     (MHz)                                            (dBuV/m)       (dBuV/m)
      345                      Normal                   83.91          64.31


   5.4.          DESCRIPTION OF AVAILABLE ANTENNAS

The radio utilizes a Loop antenna using copper wire, with a maximum peak gain of -15dBi.

   5.5.          SOFTWARE AND FIRMWARE

The typical factory firmware installed in the EUT during testing was ESW1034-05-006.

   5.6.          WORST-CASE CONFIGURATION AND MODE

The EUT was investigated in each of its three orthogonal axes. All radiated testing was
performed in the worse-case axis, which was found to be the “X-axis”. See photos for details.




                                     Page 7 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212

   5.7.          DESCRIPTION OF TEST SETUP
SUPPORT EQUIPMENT

NONE

I/O CABLES

NONE


TEST SETUP

The EUT was tested as a standalone device.


SETUP DIAGRAM FOR TESTS




                                                      EUT




                                     Page 8 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212


6. TEST AND MEASUREMENT EQUIPMENT
The following test and measurement equipment was utilized for the tests documented in this
report:

                                                  Test Equipment List
       Description               Manufacturer             Model               T Number          Cal Date          Cal Due
 Spectrum Analyzer, PXA,
                                     Agilent               N9030A                 905         02/03/2018        02/03/2019
      3Hz to 44GHz
                                                     AFS42-00101800-
  Amplifier, 1 to 18GHz               Miteq                                       493         04/03/2018        04/03/2019
                                                         25-S-42
  Amplifier, 100KHz to
                                    Keysight                8447D                  15         08/14/2017        08/14/2018
      1GHz, 32dB
 Antenna, Horn 1-18GHz            ETS Lindgren               3117                 711         01/30/2018        01/30/2019
  Antenna, Broadband
   Hybrid, 30MHz to              Sunol Sciences               JB1                 899          7/24/2018         7/24/2019
       2000MHz
                                  COM-POWER
      Loop Antenna                                         AL-130R               1866         12/31/2017        12/31/2018
                                 CORPORATION

                                                   Test Software List
Description                                     Manufacturer     Model                      Version
Radiated Software                               UL               UL EMC                     Ver 9.5, Dec 01, 2016




                                     Page 9 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212


7. ANTENNA PORT TEST RESULTS

   7.1.          DUTY CYCLE
LIMITS

FCC §15.35 (c)
The measurement field strength shall be determined by averaging over one complete pulse
train, including blanking intervals, as long as the pulse train does not exceed 0.1 seconds. As an
alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases where the
pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the
average absolute voltage during a 0.1 second interval during which the field strength is at its
maximum value. The exact method of calculating the average field strength shall be submitted
with any application for certification or shall be retained in the measurement data file for
equipment subject to notification or verification.


TEST PROCEDURE

The transmitter output is connected to a spectrum analyzer or radiated field strength. The RBW
is set to 1MHz and the VBW is set to 1MHz. The sweep time is coupled and the span is set to 0
Hz. The number of pulses is measured and calculated in a 100 ms scan.


CALCULATION

Average Reading = Peak Reading (dBuV/m) + 20log (Duty Cycle), Where Duty Cycle is
(# of long pulses * long pulse width) + (# of short pulses * short pulse width) / 100 or T


RESULTS

No non-compliance noted:

      One           Long Pulse        # of       Short       # of        Duty         20*Log
     Period            Width         Long        Width      Short       Cycle       Duty Cycle
      (ms)              (ms)        Pulses        (ms)     Pulses                      (dB)
      100              0.264           17         0.13        46        0.105          -19.60




                                     Page 10 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212


ONE PERIOD



             ONE PERIOD




                                     Page 11 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212


PULSE WIDTHS


  LONG PULSE AND SHORT PULSE WIDTHS




                                     Page 12 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212


NUMBER OF PULSES


  NUMBER OF PULSES




                                     Page 13 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                      DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                                 IC: 9863B-WST212


     7.2.

8. RADIATED EMISSION TEST RESULTS
LIMITS

FCC §15.231 (b)
RSS-210 A.1.2


In addition to the provisions of § 15.205, the field strength of emissions from Intentional
radiators operated under this section shall not exceed the following:


       Fundamental               Field strength of fundamental             Field strength of spurious emissions
     frequency (MHz)                   (microvolts/meter)                            (microvolts/meter)
       40.66-40.70                              2,250                                            225
            70-130                              1,250                                            125
            130-174                       11,250   to 3,750                                 1125   to 375
            174-260                             3,750                                            375
            260-470                      13,750    to 12,500                              1375   to 1,250
           Above 470                           12,500                                          1,250

Linear interpolation
1



§15.205 (a) Except as shown in paragraph (d) of this section, only spurious emissions are
permitted in any of the frequency bands listed below:

              MHz                          MHz                            MHz                            GHz
       0.090 - 0.110                16.42 - 16.423                   399.9 - 410                      4.5 - 5.15
       1
        0.495 - 0.505            16.69475 - 16.69525                  608 - 614                      5.35 - 5.46
      2.1735 - 2.1905            16.80425 - 16.80475                 960 - 1240                      7.25 - 7.75
       4.125 - 4.128                 25.5 - 25.67                    1300 - 1427                     8.025 - 8.5
     4.17725 - 4.17775               37.5 - 38.25                   1435 - 1626.5                     9.0 - 9.2
     4.20725 - 4.20775                 73 - 74.6                   1645.5 - 1646.5                    9.3 - 9.5
       6.215 - 6.218                  74.8 - 75.2                    1660 - 1710                     10.6 - 12.7
     6.26775 - 6.26825               108 - 121.94                  1718.8 - 1722.2                   13.25 - 13.4
     6.31175 - 6.31225                 123 - 138                     2200 - 2300                     14.47 - 14.5
       8.291 - 8.294                149.9 - 150.05                   2310 - 2390                     15.35 - 16.2
       8.362 - 8.366                 156.52475 -                    2483.5 - 2500                    17.7 - 21.4
     8.37625 - 8.38675                156.52525                      2655 - 2900                    22.01 - 23.12
     8.41425 - 8.41475              156.7 - 156.9                    3260 - 3267                     23.6 - 24.0
       12.29 - 12.293             162.0125 - 167.17                  3332 - 3339                     31.2 - 31.8
    12.51975 - 12.52025             167.72 - 173.2                  3345.8 - 3358                    36.43 - 36.5
    12.57675 - 12.57725                240 - 285                     3600 - 4400                          ( 2)
       13.36 – 13.41                 322 - 335.4

                                     Page 14 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                                FAX: (510) 661-0888
     This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212

1 Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
2 Above 38.6

§15.205 (b) Except as provided in paragraphs (d) and (e), the field strength of emissions
appearing within these frequency bands shall not exceed the limits shown in Section 15.209. At
frequencies equal to or less than 1000 MHz, compliance with the limits in Section 15.209 shall
be demonstrated using measurement instrumentation employing a CISPR quasi peak detector.
Above 1000 MHz, compliance with the emission limits in Section 15.209 shall be demonstrated
based on the average value of the measured emissions. The provisions in Section 15.35 apply
to these measurements.

§15.209 (a) Except as provided elsewhere in this Subpart, the emissions from an intentional
radiator shall not exceed the field strength levels specified in the following table:

 Frequency (MHz)            Field strength (microvolts/meter)                 Measurement distance (meters)
    0.009-0.490                          2400/F(kHz)                                           300
    0.490-1.705                          24000/F(kHz)                                           30
     1.705-30.0                                30                                               30
       30-88                                 100**                                               3
       88-216                                150**                                               3
      216-960                                200**                                               3
     Above 960                                500                                                3
** Except as provided in paragraph (g), fundamental emissions from intentional radiators
operating under this Section shall not be located in the frequency bands 54-72 MHz, 76-88
MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is
permitted under other sections of this Part, e.g., Sections 15.231 and 15.241.

§15.209 (b) In the emission table above, the tighter limit applies at the band edges.




                                     Page 15 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212


TEST PROCEDURE

The EUT is placed on a non-conducting table 80 cm above the ground plane for below 1GHz
and 150 cm for above 1GHz. The antenna to EUT distance is 3 meters. The EUT is configured
in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode.

For measurements below 1 GHz the resolution bandwidth is set to 100 kHz for peak detection
measurements or 120 kHz for quasi-peak detection measurements. Peak detection is used
unless otherwise noted.

For measurements above 1 GHz the resolution bandwidth is set to 1 MHz; the video bandwidth
is set to 3 MHz for peak measurements and add duty cycle factor for average measurements.
Please refer to test report section 7.2 for duty cycle factor information. Note: The pre-scan
measurements above 1GHz the VBW is set to 30 kHz.

The frequency range of interest is monitored at a fixed antenna height and EUT azimuth. The
EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned
from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are
made with the antenna polarized in both the vertical and the horizontal positions.

RESULTS

No non-compliance noted:




                                     Page 16 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212


FUNDAMENTAL, HARMONICS AND TX SPURIOUS EMISSION (30 – 1000 MHz)



  HORIZONTAL




  VERTICAL




                                     Page 17 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                        DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                                   IC: 9863B-WST212

                                         BELOW 1GHZ RADIATED EMISSIONS

FUNDAMENTAL FIELD STRENGTH AND HARMONICS SPURIOUS EMISSIONS
Marker       Frequency    Meter    Det     AF T899     Amp/Cbl    Corrected       Limit      Margin   Azimuth   Height   Polarity
               (MHz)     Reading            (dB/m)      (dB)       Reading      (dBuV/m)      (dB)     (Degs)    (cm)
                         (dBuV)                                   (dBuV/m)
   4          74.2445     33.85    Pk        12         -26.7       19.15         40         -20.85    112       132        V
   1          70.0534     33.65    Pk       12.1        -26.7       19.05         40         -20.95    198       146        H
   2         345.0158     90.51    Pk       18.1        -24.7       83.91        97.26       -13.35      0       115        H
                                   Av                               64.31        77.26       -12.95      0       115        H
   5         345.0175     75.36    Pk       18.1        -24.7       68.76        97.26        -28.5     74       151        V
                                   Av                               49.16        77.26         -29      74       151        V
   3        **690.0131    51.03    Pk        24         -24.6       50.43        77.26       -26.83    280       124        H
                                   Av                               30.83        57.26       -26.43    280       124        H
   6        **690.0363    41.87    Pk        24         -24.6       41.27        77.26       -35.99    102       154        V
                                   Av                               21.67        57.26       -35.59    102       154        V

Pk - Peak detector
Av – Average detector

* Average Reading = Peak Reading (dBuV/m) + 20log (Duty Cycle), Where Duty Cycle is -19.6dB
(# of long pulses * long pulse width) + (# of short pulses * short pulse width) / 100 or T
Refer to section 7.2 for duty cycle factor calculation (-19.6dB)
Note: Radiated peak result is based on 100% duty cycle sample; average reading = peak reading + DCCF
** Harmonics of fundamental 345MHz




                                     Page 18 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                                  FAX: (510) 661-0888
       This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212


HARMONICS AND TX SPURIOUS EMISSIONS ABOVE 1GHz




  HORIZONTAL




  VERTICAL




                                     Page 19 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                                  DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                                             IC: 9863B-WST212


 Marker     Frequency    Meter    Det   AF T711   Amp/Cbl   Corrected     Peak      Av Limit    Peak      Av      Azimuth   Height   Polarity
              (GHz)     Reading          (dB/m)    (dB)      Reading      Limit    (dBuV/m)    Margin   Margin     (Degs)    (cm)
                        (dBuV)                              (dBuV/m)    (dBuV/m)                (dB)     (dB)
   1         **1.035     50.69    Pk     27.3      -32.4     45.59        74           -       -28.41       -      285       196        H
                                  Av                         25.99         -          54           -    -28.01     285       196        H
  13         **1.035     47.24    Pk     27.3      -32.4     42.14        74           -       -31.86       -      228       158        V
                                  Av                         22.54         -          54           -    -31.46     228       158        V
   2         **1.38      62.4     Pk      29       -31.8      59.6        74           -        -14.4       -      295       195        H
                                  Av                           40          -          54           -      -14      295       195        H
  14         **1.38      55.04    Pk      29       -31.8     52.24        74           -       -21.76       -      206       345        V
                                  Av                         32.64         -          54           -    -21.36     206       345        V
   3         **1.725     70.35    Pk     29.4      -31.4     68.35        74           -        -5.65       -      115       200        H
                                  Av                         48.75         -          54           -     -5.25     115       200        H
  15         **1.725     60.04    Pk     29.4      -31.4     58.04        74           -       -15.96       -      13        310        V
                                  Av                         38.44         -          54           -    -15.56     13        310        V
   4         **2.07      67.48    Pk     31.3      -30.9     67.88        74           -        -6.12       -      305       137        H
                                  Av                         48.28         -          54           -     -5.72     305       137        H
  16         **2.07      60.91    Pk     31.3      -30.9     61.31        74           -       -12.69       -      197       330        V
                                  Av                         41.71         -          54           -    -12.29     197       330        V
   5         **2.414     62.84    Pk     31.9      -30.4     64.34        74           -        -9.66       -      38        310        V
                                  Av                         44.74         -          54           -     -9.26     38        310        V
  17         **2.415     67.56    Pk     31.9      -30.4     69.06        74           -        -4.94       -      127       190        H
                                  Av                         49.46         -          54           -     -4.54     127       190        H
   6         **2.76      58.76    Pk     32.3      -30.1     60.96        74           -       -13.04       -      313       227        H
                                  Av                         41.36         -          54           -    -12.64     313       227        H
  18         **2.76      54.79    Pk     32.3      -30.1     56.99        74           -       -17.01       -      25        325        V
                                  Av                         37.39         -          54           -    -16.61     25        325        V
   7         **3.105     64.58    Pk     32.9      -29.3     68.18        74           -        -5.82       -      345       114        H
                                  Av                         48.58         -          54           -     -5.42     345       114        H
  19         **3.105     55.86    Pk     32.9      -29.3     59.46        74           -       -14.54       -      58        103        V
                                  Av                         39.86         -          54           -    -14.14     58        103        V
   8         **3.45      69.2     Pk     32.7      -28.9       73         74           -          -1        -      64        126        H
                                  Av                          53.4         -          54           -      -0.6     64        126        H
  20         **3.45      52.97    Pk     32.7      -28.9     56.77        74           -       -17.23       -      75        327        V
                                  Av                         37.17         -          54           -    -16.83     75        327        V
   9         **3.795     55.02    Pk     33.2      -28.5     59.72        74           -       -14.28       -      322       130        H
                                  Av                         40.12         -          54           -    -13.88     322       130        H
  21         **3.796     38.88    Pk     33.2      -28.5     43.58        74           -       -30.42       -      123       257        V
                                  Av                         23.98         -          54           -    -30.02     123       257        V
  10         **4.14      49.57    Pk     33.4      -28.1     54.87        74           -       -19.13       -      273       119        H
                                  Av                         35.27         -          54           -    -18.73     273       119        H
  22         **4.14      41.41    Pk     33.4      -28.1     46.71        74           -       -27.29       -      204       346        V
                                  Av                         27.11         -          54           -    -26.89     204       346        V
  11         **4.485     52.52    Pk     33.8      -28.1     58.22        74           -       -15.78       -      148       124        H
                                  Av                         38.62         -          54           -    -15.38     148       124        H
  23         **4.485     42.18    Pk     33.8      -28.1     47.88        74           -       -26.12       -      170       290        V
                                  Av                         28.28         -          54           -    -25.72     170       290        V
  12         **4.83      49.97    Pk     34.2      -27.2     56.97        74           -       -17.03       -      247       162        H
                                  Av                         37.37         -          54           -    -16.63     247       162        H
  24         **4.83      41.96    Pk     34.2      -27.2     48.96        74           -       -25.04       -      114       106        V
                                  Av                         29.36         -          54           -    -24.64     114       106        V

Pk - Peak detector
Av – Average detector

* Average Reading = Peak Reading (dBuV/m) + 20log (Duty Cycle), Where Duty Cycle is -19.6dB
(# of long pulses * long pulse width) + (# of short pulses * short pulse width) / 100 or T
Refer to section 7.2 for duty cycle factor calculation (-19.6dB)
Note: Radiated peak result is based on 100% duty cycle sample; average reading = peak reading + DCCF
** Harmonics of fundamental 345MHz




                                     Page 20 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                                             FAX: (510) 661-0888
       This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                    DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                               IC: 9863B-WST212

BELOW 30MHz




  NOTE: KDB 414788 OATS and Chamber Correlation Justification
  -     Based on FCC 15.31 (f) (2): measurements may be performed at a distance closer
  than that specified in the regulations; however, an attempt should be made to avoid
  making measurements in the near field.
  -     OATs and chamber correlation testing had been performed and chamber measured
  test result is the worst case test result.




                                     Page 21 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                             FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


REPORT NO: 12446338-E1V1                                                                                                                DATE: AUGUST 16, 2018
FCC ID: XQC-WST212                                                                                                                           IC: 9863B-WST212


                                         BELOW 30MHz RADIATED EMISSIONS

Trace Markers
Marker   Frequency    Meter    Det    Loop Antenna          Cbl          Dist Corr         Corrected      Peak Limit           Margin       Avg Limit         Margin   Azimuth
           (MHz)     Reading             (dB/m)            (dB)            300m             Reading       (dBuV/m)              (dB)        (dBuV/m)           (dB)     (Degs)
                     (dBuV)                                                                (dBuVolts)
  5       .02819      41.18    Pk         15.4              .1              -80              -23.32            58.58            -81.9         38.58            -61.9    0-360
  1       .05762      37.51    Pk         14.5              .1              -80              -27.89            52.37           -80.26         32.37           -60.26    0-360
  2       .21954       43.3    Pk         13.9              .1              -80               -22.7            40.79           -63.49         20.79           -43.49    0-360
  6       .30038       42.1    Pk         13.8              .1              -80                -24             38.06           -62.06         18.06           -42.06    0-360




Pk - Peak detector
Marker   Frequency    Meter    Det   Loop Antenna (dB/m)         Cbl (dB)    Dist Corr 30m        Corrected      QP Limit (dBuV/m)       Margin   Azimuth
           (MHz)     Reading                                                                       Reading                                (dB)     (Degs)
                     (dBuV)                                                                       (dBuVolts)
  3        .86016     31.76    Pk           14.1                    .1               -40             5.96              28.93             -22.97       0-360
  7       1.24711     29.38    Pk           14.3                    .2               -40             3.88              25.71             -21.83       0-360
  8      10.88443     11.24    Pk           14.7                    .5               -40            -13.56              29.5             -43.06       0-360
  4      11.53524     11.29    Pk           14.7                    .5               -40            -13.51              29.5             -43.01       0-360




Pk - Peak detector




                                     Page 22 of 27
UL VERIFICATION SERVICES INC
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000                                                                         FAX: (510) 661-0888
      This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..



Document Created: 2018-08-16 15:45:35
Document Modified: 2018-08-16 15:45:35

© 2024 FCC.report