Test Report

FCC ID: XQC-WST100

Test Report

Download: PDF
FCCID_1558413

     FCC CFR47 PART 15 SUBPART C
   INDUSTRY CANADA RSS-210 ISSUE 8

       CERTIFICATION TEST REPORT

                   FOR

  WIRELESS SECURITY REMOTE KEYFOB

        MODEL NUMBER: WST-100

           FCC ID: XQC-WST100
            IC: 9863B-WST100

        REPORT NUMBER: 11U13988

ISSUE DATE: 2011-08-23 (Revised: 2011-09-23)

               Prepared for
                ECOLINK
         2055 CARTE DEL NOGAL
               CARLSBAD
             CA, 92011, USA

              Prepared by
   UNDERWRITERS LABORATORIES INC.
        1285 WALT WHITMAN RD.
       MELVILLE, NY 11747, U.S.A.
           TEL: (631) 271-6200
           FAX: (877) 854-3577


REPORT NO: 11U13988                                         DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                             IC: 9863B-WST100

                                         Revision History



          Issue
 Rev.     Date           Revisions                                                  Revised By
  --      8/23/11        Initial Issue                                              M. Antola
  1       9/23/11        Updated report with IC ID number                           M. Antola




                                     Page 2 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                                               DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                                                   IC: 9863B-WST100

                                             TABLE OF CONTENTS
1.     ATTESTATION OF TEST RESULTS ................................................................................. 4

2.     TEST METHODOLOGY ..................................................................................................... 5

3.     FACILITIES AND ACCREDITATION ................................................................................. 5

4.     CALIBRATION AND UNCERTAINTY ................................................................................ 5
     4.1.    MEASURING INSTRUMENT CALIBRATION .............................................................. 5
     4.2.    SAMPLE CALCULATION ............................................................................................ 5
     4.3.    MEASUREMENT UNCERTAINTY ............................................................................... 5

5.     EQUIPMENT UNDER TEST ............................................................................................... 6
     5.1.    DESCRIPTION OF EUT .............................................................................................. 6
     5.2.    DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 6
     5.3.    SOFTWARE AND FIRMWARE .................................................................................... 6
     5.4.    WORST-CASE CONFIGURATION AND MODE .......................................................... 6
     5.5.    MODIFICATIONS ........................................................................................................ 6
     5.6.    DESCRIPTION OF TEST SETUP ................................................................................ 7

6.     TEST AND MEASUREMENT EQUIPMENT ....................................................................... 9

7.     ANTENNA PORT TEST RESULTS ...................................................................................10
     7.1.    20 dB AND 99% BW ...................................................................................................10
     7.2.    DUTY CYCLE .............................................................................................................14
     7.3.    TRANSMISSION TIME ...............................................................................................18

8.     RADIATED EMISSION TEST RESULTS...........................................................................19
     8.1.    TX RADIATED SPURIOUS EMISSION ......................................................................19

9.     SETUP PHOTOS ...............................................................................................................26




                                     Page 3 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                         DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                             IC: 9863B-WST100


1. ATTESTATION OF TEST RESULTS
COMPANY NAME:                 ECOLINK
                              2055 CORTE DEL NOGAL
                              CARLSBAD, CA, 92011, USA

EUT DESCRIPTION:              Wireless Security Remote Key Fob

MODEL:                        WST-100

SERIAL NUMBER:                Non-serialized prototype

DATE TESTED:                  2011-08-17 to 2011-08-18

                                  APPLICABLE STANDARDS
                          STANDARD                                      TEST RESULTS
                   FCC PART 15 SUBPART C                                       Pass
         INDUSTRY CANADA RSS-210 Issue 8, Annex 1                              Pass
             INDUSTRY CANADA RSS-GEN Issue 3                                   Pass


Underwriters Laboratories Inc. tested the RF Exposure of the above equipment in accordance
with the requirements set forth in the above standards, using test results reported in the test
report documents referenced below and/or documentation furnished by the applicant. All
indications of Pass/Fail in this report are opinions expressed by Underwriters Laboratories Inc.
based on interpretations of these calculations. The results show that the equipment is capable
of demonstrating compliance with the requirements as documented in this report.

Note: The results documented in this report apply only to the tested sample, under the
conditions and modes of operation, as described by the referenced documents. This document
may not be altered or revised in any way unless done so by Underwriters Laboratories Inc. and
all revisions are duly noted in the revisions section. Any alteration of this document not carried
out by Underwriters Laboratories Inc. will constitute fraud and shall nullify the document. This
report must not be used by the client to claim product certification, approval, or endorsement by
NVLAP, NIST, any agency of the Federal Government, or any agency of any government.

Approved & Released For UL By:                       Tested By:




Bob DeLisi                                           Mike Antola
Senior Staff Engineer                                Senior Project Engineer
UL                                                   UL


                                     Page 4 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                           DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                               IC: 9863B-WST100


2. TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.4-2003, FCC
CFR 47 Part 2, FCC CFR 47 Part 15, RSS-GEN Issue 3, and RSS-210 Issue 8.


3. FACILITIES AND ACCREDITATION
The test sites and measurement facilities used to collect data are located at 1285 Walt Whitman
Rd. Melville, NY 11747, USA.

UL Melville is accredited by NVLAP, Laboratory Code 100255-0. The full scope of accreditation
can be viewed at http://ts.nist.gov/standards/scopes/1002550.htm.


4. CALIBRATION AND UNCERTAINTY
   4.1.        MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been
calibrated in accordance with the manufacturer's recommendations, and is traceable to
recognized national standards.


   4.2.        SAMPLE CALCULATION

Where relevant, the following sample calculation is provided:
      Field Strength (dBuV/m) = Measured Voltage (dBuV) + Antenna Factor (dB/m) +
      Cable Loss (dB) – Preamp Gain (dB)
      36.5 dBuV + 18.7 dB/m + 0.6 dB – 26.9 dB = 28.9 dBuV/m


   4.3.        MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for tests
performed on the apparatus:

               PARAMETER                      UNCERTAINTY
 Conducted Disturbance, 0.15 to 30 MHz       3.3 dB
 Radiated Disturbance, 30 to 1000 MHz        4.00 dB

Uncertainty figures are valid to a confidence level of 95%.




                                     Page 5 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


5. EQUIPMENT UNDER TEST

   5.1.       DESCRIPTION OF EUT

The WSR-100 remote is a short range wireless remote which can be used to arm and disarm a
residential security system. Commands are sent by pressing any of the four buttons on the front
of the device. The LED at the top of the WSR-100 remote will illuminate to indicate that the
button has been pressed and the command is being transmitted.

   5.2.       DESCRIPTION OF AVAILABLE ANTENNAS

The radio utilizes a permanently attached, internal loop antenna, with a maximum gain of -15
dBi.


   5.3.       SOFTWARE AND FIRMWARE

None



   5.4.       WORST-CASE CONFIGURATION AND MODE

The worst-case channel is determined as the channel with the highest output power. The EUT
was examined in all three orthogonal axes. Final testing was conducted in the worse-case
orientation, which was found to be the X-Axis.


   5.5.       MODIFICATIONS

No modifications were made during testing.




                                     Page 6 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


   5.6.       DESCRIPTION OF TEST SETUP
SUPPORT EQUIPMENT

None


I/O CABLES

None

TEST SETUP

The EUT is a standalone device. Operation is achieved by pressing the buttons.




                                     Page 7 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


SETUP DIAGRAM FOR TESTS




                                           EUT




                                     Page 8 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


      REPORT NO: 11U13988                                          DATE: 2011-08-23 (Revised: 2011-09-23)
      FCC ID: XQC-WST100                                                              IC: 9863B-WST100




      6. TEST AND MEASUREMENT EQUIPMENT

      The following test and measurement equipment was utilized for the tests documented in this
      report:

                               Test Equipment Used – Radiated Emissions
                                                                                                    Cal Due
           Description                Manufacturer         Model         Identifier   Cal Date
                                                                                                     Date
30-1000MHz
                                      Rohde &
EMI Receiver                          Schwarz          ESIB40         34968        2011-03-01 2012-03-01
Bicon Antenna                         Schaffner        VBA6106A       54           2011-04-05 2012-04-05
Log-P Antenna                         Schaffner        UPA6109        44067        2011-04-29 2012-04-29
Switch Driver                         HP               11713A         ME7A-627 NA                NA
System Controller                     Sunol Sciences SC99V            44396        NA            NA
Camera Controller                     Panasonic        WV-CU254       44395        NA            NA
RF Switch Box                         UL               1              44398        NA            NA
Measurement Software                  UL               Version 9.5    44740        NA            NA
Temp/Humidity/Pressure Meter          Cole Parmer      99760-00       4268         2010-12-07 2012-12-07
Above 1GHz (Band Optimized System)
Spectrum Analyzer                     Agilent          E4446A         72823        2011-07-26 2012-07-26
Horn Antenna (1-2 GHz)                ETS              3161-01        51442        2008-03-28 See * below
Horn Antenna (2-4 GHz)                ETS              3161-02        48107        2007-09-27 See * below
Horn Antenna (4-8 GHz)                ETS              3161-03        48106        2007-09-27 See * below
Signal Path Controller                HP               11713A         50250        NA            NA
Gain Controller                       HP               11713A         50251        NA            NA
RF Switch / Preamp Fixture            UL               BOMS1          50249        NA            NA
System Controller                     UL               BOMS2          50252        NA            NA
Measurement Software                  UL               Version 9.5    44740        NA            NA
Temp/Humidity/Pressure Meter          Cole Parmer      99760-00       4268         2010-12-07 2012-12-07
* - Note: As allowed by the calibration standard ANSI C63.4 Section 4.4.2, standard gain horns need only a
one-time calibration. Only if physical damage occurs will the horn antenna require re-calibration.
* Gain standard horn antennas (sometimes called standard gain horn antennas) need not be calibrated
beyond that which is provided by the manufacturer unless they are damaged or deterioration is suspected,
or they are used at a distance closer than 2D2/. Gain standard horn antennas have gains that are fixed by
their dimensions and dimensional tolerances.

              Test Equipment Used – Occupied Bandwidth/Cease Operation/Duty Cycle
                                                                                                     Cal Due
         Description                Manufacturer          Model         Identifier      Cal Date
                                                                                                      Date
Spectrum Analyzer                Agilent               E4446A        72822            2011-07-12 2012-07-12
Dipole Antenna                   EMCO                  3121C         3359             2010-12-08 2011-12-08
Temp/Humidity/Pressure Meter     Cole Parmer           99760-00      4268             2010-12-07 2012-12-07

                                           Page 9 of 33
      UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
      1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
       This report shall not be reproduced except in full, without the written approval of Underwriters
                                             Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100




7. ANTENNA PORT TEST RESULTS


   7.1.       20 dB AND 99% BW
LIMITS

FCC §15.231 (c)
The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices
operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the
emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the
points 20 dB down from the modulated carrier.

IC A1.1.3
For the purpose of Section A1.1, the 99% Bandwidth shall be no wider than 0.25% of the center
frequency for devices operating between 70-900 MHz. For devices operating above 900 MHz,
the emission shall be no wider than 0.5% of the center frequency.


TEST PROCEDURE

ANSI C63.4

The transmitter output is connected to the spectrum analyzer.

20dB Bandwidth: The RBW is set to 10 KHz. The VBW is set to 300 KHz. The sweep time is
coupled. Bandwidth is determined at the points 20 dB down from the modulated carrier.

99% Bandwidth: The RBW is set to 1% to 3% of the 99 % bandwidth. The VBW is set to 3 times
the RBW. The sweep time is coupled. The spectrum analyzer internal 99% bandwidth function
is utilized.




                                     Page 10 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


RESULTS

No non-compliance noted:

20dB Bandwidth
Frequency 20dB Bandwidth                    Limit               Margin
   (MHz)              (kHz)                 (kHz)                (kHz)
   433.92             58.7                 1084.8               -1026.1

99% Bandwidth
Frequency 99% Bandwidth                     Limit               Margin
   (MHz)              (kHz)                 (kHz)                (kHz)
   433.92             458.4                1084.8                -626.4




                                     Page 11 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


20dB BANDWIDTH




                                     Page 12 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


99% BANDWIDTH




                                     Page 13 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                         DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                             IC: 9863B-WST100


   7.2.           DUTY CYCLE
LIMITS

FCC §15.35 (c)
The measurement field strength shall be determined by averaging over one complete pulse
train, including blanking intervals, as long as the pulse train does not exceed 0.1 seconds. As an
alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases where the
pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the
average absolute voltage during a 0.1 second interval during which the field strength is at its
maximum value. The exact method of calculating the average field strength shall be submitted
with any application for certification or shall be retained in the measurement data file for
equipment subject to notification or verification.



TEST PROCEDURE

The transmitter output is connected to a spectrum analyzer or radiated field strength. The RBW
is set to 1 MHz and the VBW is set to 1 MHz. The sweep time is coupled and the span is set to
0 Hz. The number of pulses is measured and calculated in a 100 ms scan.



CALCULATION

Average Reading = Peak Reading (dBuV/m) + 20log (Duty Cycle), Where Duty Cycle is
(# of long pulses * long pulse width) + (# of short pulses * short pulse width) / 100 or T



RESULTS

No non-compliance noted:

          One          Long Pulse        # of       Short        # of       Duty             20*Log
         Period           Width         Long        Width       Short       Cycle       Duty Cycle
          (ms)             (ms)        Pulses        (ms)      Pulses                         (dB)
           100              2.5          1           0.23        26         0.086            -21.34




                                     Page 14 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


TRANSMISSION IN 200ms PERIOD




                                     Page 15 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


ONE TRANSMISSION




                                     Page 16 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


LONG & SHORT PULSE WIDTHS




                                     Page 17 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                         DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                             IC: 9863B-WST100


   7.3.         TRANSMISSION TIME
LIMITS

FCC §15.231 (a) (2)

IC A1.1.1 (b)

A transmitter activated automatically shall cease transmission within 5 seconds after activation.



TEST PROCEDURE

The transmitter output is connected to a spectrum analyzer or radiated field strength. The RBW
is set to 1 MHz and the VBW is set to 1 MHz. The sweep time is set to 10 seconds and the span
is set to 0 Hz.



RESULTS

No non-compliance noted:



            LESS THAN 5 SECONDS




                                     Page 18 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                          DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                              IC: 9863B-WST100




8. RADIATED EMISSION TEST RESULTS


   8.1.         TX RADIATED SPURIOUS EMISSION
LIMITS

FCC §15.231 (b)
IC A1.1.2
In addition to the provisions of § 15.205, the field strength of emissions from Intentional
radiators operated under this section shall not exceed the following:

Fundamental       Field Strength of      Field Strength of
Frequency         Fundamental Frequency  Spurious Emissions
(MHz)             (microvolts/meter)     (microvolts/meter)
______________________________________________________________

40.66 - 40.70          2,250             225
70 - 130               1,250             125
130 - 174              1,250 to 3,7501   125 to 3751
174 - 260              3,750             375
260 - 470              3,750 to 12,5001  375 to 1,2501
Above 470              12,500            1,250
_______________________________________________________________
1 Linear interpolation

§15.205 (a) Except as shown in paragraph (d) of this section, only spurious emissions are
permitted in any of the frequency bands listed below:

          MHz                      MHz                      MHz                      GHz
      0.090 - 0.110           16.42 - 16.423             399.9 - 410               4.5 - 5.15
     1
      0.495 - 0.505        16.69475 - 16.69525            608 - 614               5.35 - 5.46
    2.1735 - 2.1905        16.80425 - 16.80475           960 - 1240               7.25 - 7.75
      4.125 - 4.128            25.5 - 25.67              1300 - 1427              8.025 - 8.5
   4.17725 - 4.17775           37.5 - 38.25             1435 - 1626.5               9.0 - 9.2
   4.20725 - 4.20775             73 - 74.6             1645.5 - 1646.5              9.3 - 9.5
      6.215 - 6.218             74.8 - 75.2              1660 - 1710              10.6 - 12.7
   6.26775 - 6.26825           108 - 121.94            1718.8 - 1722.2           13.25 - 13.4
   6.31175 - 6.31225             123 - 138               2200 - 2300             14.47 - 14.5
      8.291 - 8.294           149.9 - 150.05             2310 - 2390             15.35 - 16.2
      8.362 - 8.366       156.52475 - 156.52525         2483.5 - 2500             17.7 - 21.4
   8.37625 - 8.38675           156.7 - 156.9             2655 - 2900             22.01 - 23.12
   8.41425 - 8.41475        162.0125 - 167.17            3260 - 3267              23.6 - 24.0
     12.29 - 12.293           167.72 - 173.2             3332 - 3339              31.2 - 31.8
  12.51975 - 12.52025            240 - 285              3345.8 - 3358            36.43 - 36.5
                                                                                        2
  12.57675 - 12.57725           322 - 335.4              3600 - 4400                   ()
     13.36 – 13.41

                                     Page 19 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                         DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                             IC: 9863B-WST100

1 Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
2 Above 38.6

§15.205 (b) Except as provided in paragraphs (d) and (e), the field strength of emissions
appearing within these frequency bands shall not exceed the limits shown in Section 15.209. At
frequencies equal to or less than 1000 MHz, compliance with the limits in Section 15.209 shall
be demonstrated using measurement instrumentation employing a CISPR quasi peak detector.
Above 1000 MHz, compliance with the emission limits in Section 15.209 shall be demonstrated
based on the average value of the measured emissions. The provisions in Section 15.35 apply
to these measurements.

§15.209 (a) Except as provided elsewhere in this Subpart, the emissions from an intentional
radiator shall not exceed the field strength levels specified in the following table:

Frequency         Field Strength     Measurement Distance
(MHz)             (microvolts/meter) (meters)
______________________________________________________________

30 88                 100 **                          3
88 216                150 **                          3
216 960               200 **                          3
Above 960             500                             3
_______________________________________________________________
** Except as provided in paragraph (g), fundamental emissions from intentional radiators
operating under this Section shall not be located in the frequency bands 54 72 MHz, 76 88 MHz,
174 216 MHz or 470 806 MHz. However, operation within these frequency bands is permitted
under other sections of this Part, e.g., Sections 15.231 and 15.241.

§15.209 (b) In the emission table above, the tighter limit applies at the band edges.




                                     Page 20 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


TEST PROCEDURE

The EUT is placed on a non-conducting table 80 cm above the ground plane. The antenna to
EUT distance is 3 meters. The EUT is configured in accordance with ANSI C63.4. The EUT is
set to transmit in a continuous mode.

For measurements below 1 GHz the resolution bandwidth is set to 100 kHz for peak detection
measurements or 120 kHz for quasi-peak detection measurements. Peak detection is used
unless otherwise noted as quasi-peak.

For measurements above 1 GHz the resolution bandwidth is set to 1 MHz, then the video
bandwidth is set to 1 MHz for peak measurements and 10 Hz for average measurements.

The frequency range of interest is monitored at a fixed antenna height and EUT azimuth. The
EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned
from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are
made with the antenna polarized in both the vertical and the horizontal positions.

RESULTS

No non-compliance noted:




                                     Page 21 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


FUNDAMENTAL, HARMONICS AND TX SPURIOUS EMISSION (30 – 1000 MHz)




                                     Page 22 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


tsine
veseustace murassing
WeaissSecuiy ranotetyrcp
 corsivissss
Fenesbtin
Hermeainoo—s0ooin
                       togrsivon aviees0.                               rcrinss
tes      ww            sscer       soome                        Consaes Ssn          Amun veirs
Fequeney adig: Oecr catima i) oirenizat] «tlwebs/nesOCF) leal 15231 Margn foop) onl Polaty
 wasies eesore                 wa         a3       erse use         tes     ses aer me snoien
 sersser ruzere                ma         s«       seze     ause mesa       ces sase    o ssover
Senco—1000c
                       togpiver aviees0>                                rcrinss
fes      ww            wser        ow                           Consaes Ssn          Amun veire
Fequency eadig: Oeacr catima i) Oireniaat] otfebs/nese]OCF ) lnl 15200 Margn Poop) onl Polaty
 asses movre                   iss        a3       suss     ause ress       ses aom reo asover
 sersise. rsssre               m          s«       sess     ause meis       ces anerl aco ssover

Pnreassercotasimied)
0P—tasiPesigecr
tnteineoredetecr
intopmecedeecte
Ao Anareseacor
C Cittrapeaerecer
ss—Aisseecion
caus—cornmisansczen


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100



HARMONICS AND TX SPURIOUS EMISSIONS ABOVE 1GHz




                                     Page 24 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


taine
wosesustaco meassune
Wradessecuintanotetaytoo
inve ssvasscs
Teseab oc
Herroea 100zcc0mc
                                                                          recrinss       recrinss
us       mss             sieerss sons                             conscus mesine         sosinc         wamon neure
hequiny Rexing Ontecior 20eiit) Facorlt] otlfabsimesn) EKE l 15209 ie Paax                         mage (Gep end Poiiy
 morsoss misine               rs       arss          se aise          sen        se aree        7e mss       sn sieee
 wmsois eesere                re anss                se ais           mee        s asn          7e asse iss airies
Herroaiso0scoomc
                         se
                         crzens                                           mecrinss       mecrinss
Ts       ns              mss cos                                  Conscs sesant          musine         Aumose
reqsiny Rexing Outeci {t]         Pacor{it] otlfebsimesnd OCFFRE) l 15209 ie Paas                 marge onl (enl foiiy
  mesrre. sess e              ni_ on                 aso is           as         s arrr         7e anes sn se mee
 resen. on r                  ns aase                ass ais          an         soan           7e anss ssm ves
 searsere ansere              ns 4s                  on 4s            an         sns            7e a08s iss ds en
  soins ue                    m as                   ar ainx          as         se arse        7e anss iss Bsce
Herroea ao0.socomc
                         se
                         crvens                                           mecrinss       mecrinss
Ts       ns              mmece cos                                Conscs sesant          musine         Aumose
requiny Rexing Outeci {9]         Pacor{it] otlfebsimesnd OCFFRE) l 15209 Mgie Paas               marge (Donl enl toiiy
 snsssere reas e              #7 sis                 sn ain n#                   se aies        1 as         in ssrvee
 amasiss surere               m se                   se ain sso                  se asse        7e anes is se en
Veriaiaons—2coouc
                                                                          recrinss       recrinss
Ts       ns              siars. sons                              Conscs sesant          musine         Aumose
hequiny Rexing Ontecior 20eiit). Facorlt] otlfabsimesnd EKE l 15209 ie Paas                       morge (Dorl (enl roiiy
 soreme sogsire               res      arss           se ais asas                s as           o 430 sn mower
 insesss maine                re ns                  sers aise sn                se asee        m arrs sn iss ver
Veriaizons—ccoouc
                         crvins                                           mecrinss       mecrinss
Ts       ns              mmecs cos                                Conscs sesant          musine         Aumose
Requiny Reaing Outeci {t]         Pacor{it] otlfebsimesnd OCFFRE) l 15209 ie Paas                 marge Donl (enl roiiy
 mnesers ssiore               m on                   se ais           an                        76 a0ss is s ver
 reossoss sori e              ns use                 aes ais          an                        moass        o sevr
 smoszesn mnsrme              ns 4s                  se in            as                        7e sns sis iss ver
Veriaisoos—sooouc
                         se
                         cnvns                                            mecrinss       mecrinss
Ts       ns              mmecs cos                                Conscs sesant          musine         Aumose
requiny Rexing Onteci {t]         Pacor{it] otlfebsimesnd OCFFRE) l 15209 ie Paax                 mage (Sep (end foiiy
  snosss cose e               ms sis                 sroe aise        as>        s ass          7 asse an sn ver
 srsorie. sesie               m se                   ae ain com                  sarn           Te arsr iss socver
HOTE incoracadra comparesson CePacs Peatim
Pecreakcsrimimies)
09—tasrenccencse
tnte—inanArogeusacor
Appetoptrongecewcr
Ar eamsatecss
Civ— sttnrapedecr
mis—mscetcion
cousoseasuissencsn


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100




9. SETUP PHOTOS
ANTENNA PORT




                                     Page 26 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


RADIATED EMISSION FOR PORTABLE CONFIGURATION – X ORIENTATION




           RADIATED EMISSION FOR PORTABLE CONFIGURATION – X
           ORIENTATION




                                     Page 27 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100

RADIATED EMISSION FOR PORTABLE CONFIGURATION – Y ORIENTATION




           RADIATED EMISSION FOR PORTABLE CONFIGURATION – Y
           ORIENTATION




                                     Page 28 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


RADIATED EMISSION FOR PORTABLE CONFIGURATION – Z ORIENTATION




           RADIATED EMISSION FOR PORTABLE CONFIGURATION – Z
           ORIENTATION




                                     Page 29 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


RADIATED EMISSION BELOW 1 GHz




           RADIATED EMISSIONS BELOW 1GHz (FRONT)




                                     Page 30 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100




           RADIATED EMISSIONS BELOW 1GHz (BACK)




                                     Page 31 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100


RADIATED EMISSION ABOVE 1 GHz




           RADIATED EMISSIONS ABOVE 1 GHz (FRONT)




                                     Page 32 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.


REPORT NO: 11U13988                                        DATE: 2011-08-23 (Revised: 2011-09-23)
FCC ID: XQC-WST100                                                            IC: 9863B-WST100




           RADIATED EMISSIONS ABOVE 1 GHz (BACK)




                                    END OF REPORT




                                     Page 33 of 33
UNDERWRITERS LABORATORIES INC.                                       FORM NO: CCSUP4701D
1285 WALT WHITMAN RD, MELVILLE, NY 11747, USA    TEL: (631) 271-6200    FAX: (877) 854-3577
 This report shall not be reproduced except in full, without the written approval of Underwriters
                                       Laboratories Inc.



Document Created: 2011-09-23 07:33:54
Document Modified: 2011-09-23 07:33:54

© 2024 FCC.report