11908433-E1V2 FCCIC Report 15.231

FCC ID: XQC-TXENCKF

Test Report

Download: PDF
FCCID_3783212

    FCC 47 CFR PART 15 SUBPART C
             ISED RSS 210

     CERTIFICATION TEST REPORT

                 FOR

         WIRELESS KEYFOB

     MODEL NUMBER: TX-ENC-KF

        FCC ID: XQC-TXENCKF
       ISED ID: 9863B-TXENCKF

   REPORT NUMBER: 11908433-E1V1

    ISSUE DATE: February 20th, 2018



             Prepared for
ECOLINK INTELLIGENT TECHNOLOGY, INC.
       2055 CORTE DEL NOGAL
      CARLSBAD, CA, 92011, U.S.A


              Prepared by
    UL VERIFICATION SERVICES INC.
        47173 BENICIA STREET
      FREMONT, CA 94538, U.S.A.
          TEL: (510) 771-1000
          FAX: (510) 661-0888




        NVLAP LAB CODE 200065-0


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF

                                                 Revision History


            Issue
 Rev.       Date             Revisions                                                                  Revised By
  V1        08/25/17         Initial Issue
  V2        02/20/18         Updated section 5.2 and 9                                                  C. Susa




                                     Page 2 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                             th
REPORT NO: 11908433-E1V2                                                                              DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                                   ISED ID: 9863B-TXENCKF
                                             TABLE OF CONTENTS
1.     ATTESTATION OF TEST RESULTS ................................................................................. 4

2.     TEST METHODOLOGY ..................................................................................................... 5

3.     FACILITIES AND ACCREDITATION ................................................................................. 5

4.     CALIBRATION AND UNCERTAINTY ................................................................................ 6
     4.1.    MEASURING INSTRUMENT CALIBRATION .............................................................. 6
     4.2.    SAMPLE CALCULATION ............................................................................................ 6
     4.3.    MEASUREMENT UNCERTAINTY ............................................................................... 6

5.     EQUIPMENT UNDER TEST ............................................................................................... 7
     5.1.    DESCRIPTION OF EUT .............................................................................................. 7
     5.2.    MAXIMUM FIELD STRENGTH .................................................................................... 7
     5.3.    DESCRIPTION OF AVAILABLE ANTENNAS .............................................................. 7
     5.4.    SOFTWARE AND FIRMWARE .................................................................................... 7
     5.5.    WORST-CASE CONFIGURATION AND MODE .......................................................... 7
     5.6.    MODIFICATIONS ........................................................................................................ 7
     5.7.    DESCRIPTION OF TEST SETUP ................................................................................ 8

6.     TEST AND MEASUREMENT EQUIPMENT ....................................................................... 9

7.     ANTENNA PORT TEST RESULTS ...................................................................................10
     7.1.    20 dB AND 99% BW ...................................................................................................10
     7.2.    DUTY CYCLE .............................................................................................................12
     7.3.    SUPERVISION TRANSMISSIONS .............................................................................15
     7.4.    TRANSMISSION TIME ...............................................................................................16

8.     RADIATED EMISSION TEST RESULTS...........................................................................17

9.     SETUP PHOTOS ...............................................................................................................26




                                     Page 3 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
      This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF

1. ATTESTATION OF TEST RESULTS
COMPANY NAME:                       ECOLINK INTELLIGENT TECHNOLOGY, INC.
                                    2055 CORTE DEL NOGAL
                                    CARLSBAD, CA, 92011, U.S.A

EUT DESCRIPTION:                    Wireless KeyFob

MODEL:                              TX-ENC-KF

SERIAL NUMBER:                      422-5841

DATE TESTED:                        AUGUST 14 to 24, 2017

                                         APPLICABLE STANDARDS
                              STANDARD                                                  TEST RESULTS
                      FCC PART 15 SUBPART C                                                 Complies
                   ISED RSS-210 Issue 9, Annex A                                            Complies
                        ISED RSS-GEN Issue 4                                                Complies


UL Verification Services Inc tested the above equipment in accordance with the requirements
set forth in the above standards. All indications of Pass/Fail in this report are opinions
expressed by UL Verification Services Inc. based on interpretations and/or observations of test
results. Measurement Uncertainties were not taken into account and are published for
informational purposes only. The test results show that the equipment tested is capable of
demonstrating compliance with the requirements as documented in this report.

Note: The results documented in this report apply only to the tested sample, under the
conditions and modes of operation as described herein. This document may not be altered or
revised in any way unless done so by UL Verification Services Inc. and all revisions are duly
noted in the revisions section. Any alteration of this document not carried out by UL Verification
Services Inc will constitute fraud and shall nullify the document. This report must not be used
by the client to claim product certification, approval, or endorsement by NVLAP, NIST, any
agency of the Federal Government, or any agency of the U.S. government.

Approved & Released For
UL Verification Services Inc By:                                 Prepared By:




DAN CORONIA                                                     ERIC YU
OPERATIONS LEADER                                               TEST ENGINEER
UL Verification Services Inc.                                   UL Verification Services Inc.




                                     Page 4 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF

2. TEST METHODOLOGY
The tests documented in this report were performed in accordance with ANSI C63.10-2013,
FCC CFR 47 Part 2, FCC CFR 47 Part 15, RSS-GEN Issue 4, and RSS-210 Issue 9.


3. FACILITIES AND ACCREDITATION
The test sites and measurement facilities used to collect data are located at 47173 Benicia
Street, Fremont, California, USA.

The test sites and measurement facilities used to collect data are located at 47173 and 47266
Benicia Street, Fremont, California, USA. Line conducted emissions are measured only at the
47173 address. The following table identifies which facilities were utilized for radiated emission
measurements documented in this report. Specific facilities are also identified in the test results
sections.

                  47173 Benicia Street                                   47266 Benicia Street
                 Chamber A (ISED:2324B-1)                               Chamber D (ISED:22541-1)
                 Chamber B (ISED:2324B-2)                               Chamber E (ISED:22541-2)
                 Chamber C (ISED:2324B-3)                               Chamber F (ISED:22541-3)
                                                                        Chamber G (ISED:22541-4)
                                                                        Chamber H (ISED:22541-5)

The above test sites and facilities are covered under FCC Test Firm Registration # 208313.
Chambers A through C are covered under ISED company address code 2324B with site
numbers 2324B -1 through 2324B-3, respectively. Chambers D through H are covered under
Industry Canada company address code 22541 with site numbers 22541 -1 through 22541-5,
respectively.

UL Verification Services Inc. is accredited by NVLAP, Laboratory Code 200065-0. The full
scope of accreditation can be viewed at http://ts.nist.gov/standards/scopes/2000650.htm.




                                     Page 5 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                    DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                         ISED ID: 9863B-TXENCKF



4. CALIBRATION AND UNCERTAINTY
   4.1.          MEASURING INSTRUMENT CALIBRATION
The measuring equipment utilized to perform the tests documented in this report has been
calibrated in accordance with the manufacturer's recommendations, and is traceable to
recognized national standards.


   4.2.          SAMPLE CALCULATION

Where relevant, the following sample calculation is provided:
      Field Strength (dBuV/m) = Measured Voltage (dBuV) + Antenna Factor (dB/m) +
      Cable Loss (dB) – Preamp Gain (dB)
      36.5 dBuV + 18.7 dB/m + 0.6 dB – 26.9 dB = 28.9 dBuV/m


   4.3.          MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for tests
performed on the apparatus:

                                Parameter                                        Uncertainty

      Worst Case Radiated Disturbance, 9KHz to 30 MHz                            3.15 dB
      Worst Case Radiated Disturbance, 30 to 1000 MHz                            5.36 dB
      Worst Case Radiated Disturbance, 1000 to 18000 MHz                         4.32 dB
      Worst Case Radiated Disturbance, 18000 to 26000 MHz                        4.45 dB
      Worst Case Radiated Disturbance, 26000 to 40000 MHz                        5.24 dB

Uncertainty figures are valid to a confidence level of 95%.




                                     Page 6 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF

5. EQUIPMENT UNDER TEST

   5.1.          DESCRIPTION OF EUT

The EUT is Wireless KeyFob which is operated by 3Vdc lithium CR2032 battery in
433.65MHz frequency.


   5.2.          MAXIMUM FIELD STRENGTH
The transmitter has the maximum peak and average radiated field strengths as follows:

    Frequency                    Mode               Field Strength          Field Strength
      Range                                              Peak                  Average
      (MHz)                                           (dBuV/m)                (dBuV/m)
      433.65                    Normal                   87.88                   71.45


   5.3.          DESCRIPTION OF AVAILABLE ANTENNAS
Antenna comprises of a printed circuit loop type radiator. The antenna is printed around the
periphery of the circuit board. The peak gain of the antenna is approximately -15dBi.

   5.4.          SOFTWARE AND FIRMWARE

The typical factory firmware installed in the EUT during testing was ESW1123-01-D01

The firmware installed in the EUT to allow continuous transmit during testing was ESW1123-01-
const_tx


   5.5.          WORST-CASE CONFIGURATION AND MODE

The EUT was investigated in each of its three orthogonal axes. All radiated testing was
performed in the worse-case axis, which was found to be the X-axis. See photos for details.


   5.6.          MODIFICATIONS

No modifications were made during testing.




                                     Page 7 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF

   5.7.          DESCRIPTION OF TEST SETUP
SUPPORT EQUIPMENT

NONE

I/O CABLES

None

TEST SETUP


SETUP DIAGRAM FOR TESTS




The EUT is operated by 3V lithium CR2032 battery.




                                     Page 8 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF



6. TEST AND MEASUREMENT EQUIPMENT

The following test and measurement equipment was utilized for the tests documented in this
report:

                                                Test Equipment List
                                                                                T
       Description               Manufacturer               Model                            Cal Date         Cal Due
                                                                              Number
 Spectrum Analyzer, PXA,
                                     Agilent               N9030A                908       04/13/2017 04/13/2018
      3Hz to 44GHz
                                                     AFS42-00101800-
  Amplifier, 1 to 18GHz              Miteq                                      1165        8/1/2017         8/1/2018
                                                         25-S-42
                                                         AMF-4D-
  Amplifier, 1 to 8 GHz              Miteq                                      1170       4/28/2017        4/28/2018
                                                     01000800-30-29P
Amplifier, 10KHz to 1GHz,
                                    Sonoma                   310                 300       11/10/2016 11/10/2017
           32dB
 Antenna, Horn 1-18GHz           ETS Lindgren                3117                346       02/22/2017 02/22/2018
  Antenna, Broadband
                                     Sunol
   Hybrid, 30MHz to                                           JB1                130       9/23/2016        9/23/2017
                                    Sciences
        2000MHz
     Loop Antenna                 ETS Lindgren              6502                757         12/22/16         12/22/17


                                                  Test Software List
Description                                     Manufacturer          Model                 Version
Radiated Software                               UL                    UL EMC                Ver 9.5, Dec 01, 2016
Antenna Port Software                           UL                    UL RF                 Ver 5.1.1, July 15, 2016




                                     Page 9 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF



7. ANTENNA PORT TEST RESULTS

   7.1.          20 dB AND 99% BW
LIMITS

FCC §15.231 (c)
The bandwidth of the emission shall be no wider than 0.25% of the center frequency for devices
operating above 70 MHz and below 900 MHz. For devices operating above 900 MHz, the
emission shall be no wider than 0.5% of the center frequency. Bandwidth is determined at the
points 20 dB down from the modulated carrier.

RSS-210 A.1.3
The 99% bandwidth of monetarily operated devices shall be less or equal to 0.25% of the center
frequency for devices operating between 70MHz and 900MHz. For devices operating above
900MHz, the 99% bandwidth shall be less or equal to 0.5% of the center frequency.


TEST PROCEDURE

ANSI C63.10

The transmitter output is connected to the spectrum analyzer.

20dB Bandwidth: The RBW is set to 1% to 5% of OBW. The VBW is set to 3 times the RBW.
The sweep time is coupled. Bandwidth is determined at the points 20 dB down from the
modulated carrier.

99% Bandwidth: The RBW is set to 1% to 3% of the 99 % bandwidth. The VBW is set to 3 times
the RBW. The sweep time is coupled. The spectrum analyzer internal 99% bandwidth function
is utilized.




                                     Page 10 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF

RESULTS

No non-compliance noted:

20dB Bandwidth
Frequency 20dB Bandwidth                              Limit                    Margin
   (MHz)                  (kHz)                      (kHz)                       (kHz)
   433.65                  80.39                   1084.125                   -1003.735

99% Bandwidth
Frequency 99% Bandwidth                               Limit                    Margin
   (MHz)                  (kHz)                      (kHz)                       (kHz)
   433.65                  61.19                   1084.125                   -1022.935



20dB & 99% BANDWIDTH



             20dB & 99% BANDWIDTH




                                     Page 11 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF



   7.2.          DUTY CYCLE
LIMITS

FCC §15.35 (c)
The measurement field strength shall be determined by averaging over one complete pulse
train, including blanking intervals, as long as the pulse train does not exceed 0.1 seconds. As an
alternative (provided the transmitter operates for longer than 0.1 seconds) or in cases where the
pulse train exceeds 0.1 seconds, the measured field strength shall be determined from the
average absolute voltage during a 0.1 second interval during which the field strength is at its
maximum value. The exact method of calculating the average field strength shall be submitted
with any application for certification or shall be retained in the measurement data file for
equipment subject to notification or verification.


TEST PROCEDURE

The transmitter output is connected to a spectrum analyzer or radiated field strength. The RBW
is set to 1MHz and the VBW is set to 1MHz. The sweep time is coupled and the span is set to 0
Hz. The number of pulses is measured and calculated in a 100 ms scan.



CALCULATION

Average Reading = Peak Reading (dBuV/m) + 20log (Duty Cycle), Where Duty Cycle is
(# of long pulses * long pulse width) + (# of short pulses * short pulse width) / 100 or T



RESULTS

No non-compliance noted:


       One             Pulse        # of        Duty        20*Log
     Period            Width      Pulses       Cycle      Duty Cycle
       (ms)            (ms)                                  (dB)
         100           7.540         2         0.151         -16.43




                                     Page 12 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF

ONE PERIOD


             ONE PERIOD




PULSE WIDTHS


             PULSE WIDTHS




                                     Page 13 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF

NUMBER OF PULSES




             NUMBER OF PULSES




                                     Page 14 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF

   7.3.           SUPERVISION TRANSMISSIONS
LIMITS

FCC §15.231 (a) (3)

Periodic transmissions at regular predetermined intervals are not permitted. However, polling or
supervision transmissions, including data, to determine system integrity of transmitters used in
security or safety applications are allowed if the total duration of transmissions does not exceed
more than two seconds per hour for each transmitter. There is no limit on the number of
individual transmissions, provided the total transmission time does not exceed two seconds per
hour


Results

   1. According to manufacturer technical description, the device transmits brief supervisory
      signal at approximately 70 minutes intervals.

   2. One pulse stream is 7.54 ms * 2 = 15.08ms. Base on section 7.4 test plot, one transition
      contain 8 pulse streams which is 15.08ms * 8 = 120.64ms




                                     Page 15 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF

   7.4.          TRANSMISSION TIME
LIMITS

FCC §15.231 (a) (1)

RSS-210 A.1.1 (a)

A manually operated transmitter shall employ a switch that will automatically deactivate the
transmitter within not more than 5 seconds of being released.


TEST PROCEDURE

The transmitter output is connected to a spectrum analyzer or radiated field strength. The RBW
is set to 1MHz and the VBW is set to 1MHz. The sweep time is set to 10 seconds and the span
is set to 0 Hz.



RESULTS

No non-compliance noted:



             LESS THAN 5 SECONDS




                                     Page 16 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                   th
REPORT NO: 11908433-E1V2                                                                       DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                            ISED ID: 9863B-TXENCKF

8. RADIATED EMISSION TEST RESULTS
LIMITS

FCC §15.231 (b)
RSS-210 A.1.2

In addition to the provisions of § 15.205, the field strength of emissions from Intentional
radiators operated under this section shall not exceed the following:

       Fundamental               Field strength of fundamental             Field strength of spurious emissions
     frequency (MHz)                   (microvolts/meter)                            (microvolts/meter)
       40.66-40.70                              2,250                                             225
            70-130                              1,250                                             125
                                          1                                                   1
            130-174                          1,250 to 3,750                                   125 to 375
            174-260                             3,750                                             375
                                         1                                                1
            260-470                       3,750 to 12,500                                  375 to 1,250
           Above 470                            12,500                                            1,250

1
Linear interpolation

§15.205 (a) Except as shown in paragraph (d) of this section, only spurious emissions are
permitted in any of the frequency bands listed below:

              MHz                             MHz                         MHz                             GHz
       0.090 - 0.110                16.42 - 16.423                   399.9 - 410                       4.5 - 5.15
       1
        0.495 - 0.505            16.69475 - 16.69525                  608 - 614                       5.35 - 5.46
      2.1735 - 2.1905            16.80425 - 16.80475                 960 - 1240                       7.25 - 7.75
       4.125 - 4.128                 25.5 - 25.67                    1300 - 1427                      8.025 - 8.5
     4.17725 - 4.17775               37.5 - 38.25                   1435 - 1626.5                      9.0 - 9.2
     4.20725 - 4.20775                 73 - 74.6                   1645.5 - 1646.5                     9.3 - 9.5
       6.215 - 6.218                  74.8 - 75.2                    1660 - 1710                      10.6 - 12.7
     6.26775 - 6.26825               108 - 121.94                  1718.8 - 1722.2                    13.25 - 13.4
     6.31175 - 6.31225                 123 - 138                     2200 - 2300                      14.47 - 14.5
       8.291 - 8.294                149.9 - 150.05                   2310 - 2390                      15.35 - 16.2
       8.362 - 8.366                 156.52475 -                    2483.5 - 2500                     17.7 - 21.4
     8.37625 - 8.38675                156.52525                      2655 - 2900                     22.01 - 23.12
     8.41425 - 8.41475              156.7 - 156.9                    3260 - 3267                      23.6 - 24.0
       12.29 - 12.293             162.0125 - 167.17                  3332 - 3339                      31.2 - 31.8
    12.51975 - 12.52025             167.72 - 173.2                  3345.8 - 3358                     36.43 - 36.5
    12.57675 - 12.57725                240 - 285                     3600 - 4400                           ( 2)
       13.36 – 13.41                 322 - 335.4




                                     Page 17 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
     This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF
1 Until February 1, 1999, this restricted band shall be 0.490-0.510 MHz.
2 Above 38.6

§15.205 (b) Except as provided in paragraphs (d) and (e), the field strength of emissions
appearing within these frequency bands shall not exceed the limits shown in Section 15.209. At
frequencies equal to or less than 1000 MHz, compliance with the limits in Section 15.209 shall
be demonstrated using measurement instrumentation employing a CISPR quasi peak detector.
Above 1000 MHz, compliance with the emission limits in Section 15.209 shall be demonstrated
based on the average value of the measured emissions. The provisions in Section 15.35 apply
to these measurements.

§15.209 (a) Except as provided elsewhere in this Subpart, the emissions from an intentional
radiator shall not exceed the field strength levels specified in the following table:

 Frequency (MHz)            Field strength (microvolts/meter)                 Measurement distance (meters)
0.009-0.490                              2400/F(kHz)                                           300
0.490-1.705                              24000/F(kHz)                                           30
1.705-30.0                                     30                                               30
30-88                                        100**                                               3
88-216                                       150**                                               3
216-960                                      200**                                               3
Above 960                                     500                                                3
** Except as provided in paragraph (g), fundamental emissions from intentional radiators
operating under this Section shall not be located in the frequency bands 54-72 MHz, 76-88
MHz, 174-216 MHz or 470-806 MHz. However, operation within these frequency bands is
permitted under other sections of this Part, e.g., Sections 15.231 and 15.241.

§15.209 (b) In the emission table above, the tighter limit applies at the band edges.




                                     Page 18 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF

TEST PROCEDURE

The EUT is placed on a non-conducting table 80 cm above the ground plane for below 1GHz
and 150 cm for above 1GHz. The antenna to EUT distance is 3 meters. The EUT is configured
in accordance with ANSI C63.10. The EUT is set to transmit in a continuous mode.

For measurements below 1 GHz the resolution bandwidth is set to 100 kHz for peak detection
measurements or 120 kHz for quasi-peak detection measurements. Peak detection is used
unless otherwise noted as quasi-peak.

For measurements above 1 GHz the resolution bandwidth is set to 1 MHz; the video bandwidth
is set to 3 MHz for peak measurements and add duty cycle factor for average measurements.
Please refer to test report section 7.2 for duty cycle factor information. Note: The pre-scan
measurements above 1GHz the VBW is set to 30 kHz.

The frequency range of interest is monitored at a fixed antenna height and EUT azimuth. The
EUT is rotated through 360 degrees to maximize emissions received. The antenna is scanned
from 1 to 4 meters above the ground plane to further maximize the emission. Measurements are
made with the antenna polarized in both the vertical and the horizontal positions.

RESULTS

No non-compliance noted:




                                     Page 19 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF

FUNDAMENTAL, HARMONICS AND TX SPURIOUS EMISSION (30 – 1000 MHz)



         HORIZONTAL




         VERTICAL




                                     Page 20 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                                                                      th
REPORT NO: 11908433-E1V2                                                                                                                      DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                                                                           ISED ID: 9863B-TXENCKF

BELOW 1GHZ RADIATED EMISSIONS

Trace Markers
Marker     Frequency    Meter       Det    AF T130 (dB/m)          Amp/Cbl (dB/m)           Corrected       Class B QPk Limit        Margin      Azimuth   Height    Polarity
             (MHz)     Reading                                                               Reading            (dBuV/m)              (dB)        (Degs)    (cm)
                       (dBuV)                                                               (dBuV/m)
  1         80.8006    33.68        Pk          11.6                   -30.7                 14.58                  40               -25.42      0-360      200         H
  2         81.7784    38.31        Pk          11.5                   -30.7                 19.11                  40               -20.89      0-360      100         V
 *3        433.6304    94.44        Pk          20.7                   -28.9                 86.24                   -                  -        0-360      101         H
 *5        433.6304    78.4         Pk          20.7                   -28.9                 70.2                    -                  -        0-360      200         V
 **4       867.2867    45.8         Pk          25.8                   -27.6                  44                    -                    -       0-360      101         H
 **6       867.2867    35.15        Pk          25.8                   -27.6                 33.35                  -                    -       0-360      200         V



Pk - Peak detector


FUNDAMENTAL AND HARMONICS SPURIOUS EMISSIONS

  Marker       Frequency        Meter     Det      AF T130 (dB/m)           Amp/Cbl (dB/m)              Corrected             Limit             Margin     Azimuth      Height   Polarity
                 (MHz)         Reading                                                                   Reading            (dBuV/m)             (dB)       (Degs)       (cm)
                               (dBuV)                                                                   (dBuV/m)
   *3          433.6482          96.08    Pk                20.7                    -28.9                87.88                  100.82          -12.94      287            118      H
                                          Av                                                             71.45                   80.82           -9.37                              H
   *5          433.6525          77.8     Pk                20.7                    -28.9                69.6                   100.82          -31.22      163            183      V
                                          Av                                                             53.17                   80.82          -27.65                              V
   **6         867.2737          37.03    Pk                25.8                    -27.6                35.23                   80.82          -45.59      311            118      V
                                          Av                                                             18.80                   60.82          -42.02                              V
   **4         867.2891          47.7     Pk                25.8                    -27.6                45.9                    80.82          -34.92      269            114      H
                                          Av                                                             29.47                   60.82          -31.35                              H


* Fundamental
** Harmonic



Average Reading = Peak Reading (dBuV/m) + 20log (Duty Cycle), Where Duty Cycle is -16.43dB
(# of pulses * pulse width) / 100 or T
Refer to section 7.2 for duty cycle factor calculation (-16.43dB).

Note: Radiated peak result is based on 100% duty cycle sample; average reading = peak reading + DCCF.




                                     Page 21 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
       This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF

HARMONICS AND TX SPURIOUS EMISSIONS ABOVE 1GHz


         HORIZONTAL




         VERTICAL




                                     Page 22 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                                                        th
REPORT NO: 11908433-E1V2                                                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                                                        ISED ID: 9863B-TXENCKF
Radiated Emissions
 Marker   Frequency    Meter    Det   AF T862 (dB/m)   Amp/Cbl (dB)   Corrected   Class B Avg Limit   Margin   Class B Pk Limit   PK Margin   Azimuth        Height   Polarity
            (GHz)     Reading                                          Reading       (dBuV/m)          (dB)       (dBuV/m)           (dB)      (Degs)         (cm)
                      (dBuV)                                          (dBuV/m)
  **1      1.735      40.44     Pk        29.5            -32.8        37.14             -               -           74            -36.86       46           246         H
                                Av                                     20.71            54            -33.29          -               -                                  H
  **9      1.735      42.36     Pk        29.5            -32.8        39.06             -               -           74            -34.94       24           222         V
                                Av                                     22.63            54            -31.37          -               -                                  V
  **2      2.168        48      Pk        31.1            -32.1          47              -               -           74              -27        1            120         H
                                Av                                     30.57            54            -23.43          -               -                                  H
 **10      2.168       46.7     Pk        31.1            -32.1         45.7             -               -           74             -28.3      357           119         V
                                Av                                     29.27            54            -24.73          -               -                                  V
  **3      2.602      41.85     Pk        32.4            -31.5        42.75             -               -           74            -31.25       1            190         H
                                Av                                     26.32            54            -27.68          -               -                                  H
 **11      2.602      46.02     Pk        32.4            -31.5        46.92             -               -           74            -27.08       12           148         V
                                Av                                     30.49            54            -23.51          -               -                                  V
  **4      3.035      44.41     Pk        32.6             -31         46.01             -               -           74            -27.99      239           112         H
                                Av                                     29.58            54            -24.42          -               -                                  H
 **12      3.036      29.77     Pk        32.6             -31         44.99             -               -           74            -29.01       1            101         V
                                Av                                     28.56            54            -25.44                                                             V
  **5      3.469      47.07     Pk        32.7            -30.5        49.27             -               -           74            -24.73       24           111         H
                                Av                                     32.84            54            -21.16          -               -                                  H
 **13      3.469      44.51     Pk        32.7            -30.5        46.71             -               -           74            -27.29      355           109         V
                                Av                                     30.82            54            -23.72          -               -                                  V
 **14      3.902      41.68     Pk        33.1            -29.7        45.08             -               -           74            -28.92      335           135         V
                                Av                                     28.65            54            -25.35                                                             V
  **6      3.903      30.25     Pk        33.1            -29.7        53.29             -               -           74            -20.71      211           119         H
                                Av                                     36.86            54            -17.14          -               -                                  H
 **15      4.336      38.45     Pk        33.6            -28.9        53.21             -               -           74            -20.79       0            125         V
                                Av                                     36.78            54            -17.22                                                             V
  **7      4.336      32.09     Pk        33.6            -28.9        60.47             -               -           74            -13.53      197           149         H
                                Av                                     44.04            54             -9.96                                                             H
  **8       4.77      42.48     Pk        34.1            -28.3        48.28             -               -           74            -25.72      341           125         H
                                Av                                     31.85            54            -22.15          -               -                                  H
 **16       4.77      42.22     Pk        34.1            -28.3        48.02             -               -           74            -25.98      178           103         V
                                Av                                     31.59            54            -22.41                                                             V



* Fundamental
** Harmonic

Pk - Peak detector
Average Reading = Peak Reading (dBuV/m) + 20log (Duty Cycle), Where Duty Cycle is -16.43dB
(# of pulses * pulse width) / 100 or T
Refer to section 7.2 for duty cycle factor calculation (-16.43dB)

Note: Radiated peak result is based on 100% duty cycle sample; average reading = peak reading + DCCF.




                                     Page 23 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
     This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                 th
REPORT NO: 11908433-E1V2                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                        ISED ID: 9863B-TXENCKF

BELOW 30MHz




  NOTE: KDB 414788 OATS and Chamber Correlation Justification
  -     Based on FCC 15.31 (f) (2): measurements may be performed at a distance closer than
  that specified in the regulations; however, an attempt should be made to avoid making
  measurements in the near field.
  -     OATs and chamber correlation testing had been performed and chamber measured test
  result is the worst case test result.




                                     Page 24 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
   This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..


                                                                                                                                                                          th
REPORT NO: 11908433-E1V2                                                                                                                   DATE: February 20 , 2018
FCC ID:XQC-TXENCKF                                                                                                                        ISED ID: 9863B-TXENCKF

BELOW 30MHz RADIATED EMISSIONS

Trace Markers
Mar   Frequency    Meter    Det     Loop     Cbl     Dist    Corrected   Peak Limit   Margin   Avg Limit   Margin   Peak Limit   Margin    Avg Limit   Margin   Azimuth
ker     (MHz)     Reading         Antenna   (dB)     Corr     Reading    (dBuV/m)      (dB)    (dBuV/m)     (dB)    (dBuV/m)      (dB)     (dBuV/m)     (dB)     (Degs)
                  (dBuV)           (dB/m)           300m    (dBuVolts)
1      .0243      41.86     Pk     14.9     1.4     -80      -21.84       59.87       -81.71    39.87      -61.71       -          -           -         -      0-360
5      .03546     41.05     Pk     13.8     1.4     -80      -23.75       56.59       -80.34    36.59      -60.34      -            -         -           -     0-360
2      .18892     47.13     Pk     11.6     1.5     -80      -19.77         -            -        -           -      42.09       -61.86     22.09      -41.86   0-360
6      .30171     42.29     Pk     11.5     1.5     -80      -24.71          -          -          -         -       38.02       -62.73     18.02      -42.73   0-360


Pk - Peak detector

Mar   Frequency    Meter    Det     Loop      Cbl    Dist    Corrected    QP Limit    Margin   Azimuth
ker     (MHz)     Reading         Antenna    (dB)    Corr     Reading    (dBuV/m)      (dB)     (Degs)
                  (dBuV)           (dB/m)           300m    (dBuVolts)
3      .89721      32.99     Pk     11.5     1.5     -40      5.99         28.56      -22.57    0-360
7      1.41378     27.58     Pk     11.5     1.5     -40       .58         24.62      -24.04    0-360
4     26.18523     13.86     Pk      8.7     1.7     -40     -15.74         29.5      -45.24    0-360
8     29.40154     10.45     Pk      8.1     1.7     -40     -19.75         29.5      -49.25    0-360


Pk - Peak detector




                                     Page 25 of 31
UL VERIFICATION SERVICES INC                                         FORM NO: CCSUP4701I
47173 BENICIA STREET, FREMONT, CA 94538, USA     TEL: (510) 771-1000    FAX: (510) 661-0888
      This report shall not be reproduced except in full, without the written approval of UL Verification Services Inc..



Document Created: 2018-03-16 03:21:40
Document Modified: 2018-03-16 03:21:40

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC