        4. TROUBLESHOOTING
    If you encounter one of the following problems with the PIRZB1-ECO, use the following solutions to
    resolve the problem:
                                                                                                                                                          PIRZB1-ECO
                                                                                                                                                          Wireless Digital Pet Resistant PIR Detector
       Problem                                                                Solution                                                                    3rd Party Certifications: FCC, IC, ETL, ZigBee HA, iControl                                             Installation Instructions
       Attempt to pair the sensor is unsuccessful.                            Reset the detector to default mode and then set to
                                                                              pairing mode (see section 3.5).

       The sensor and the Touchscreen (control panel)                         Perform the signal strength testing procedure
       do not communicate.                                                    described in the control panel installation manual.
                                                                              Make sure that the signal is sufficient. If necessary,
                                                                                                                                                         1. INTRODUCTION
                                                                              replace the sensor’s battery.                                            The PIRZB1-ECO pet resistant detector is a
       The sensor sends a Low Battery indication.                             To ensure continuous proper operation, replace the
                                                                                                                                                       microprocessor-controlled wireless digital PIR
                                                                              battery within two weeks of the first Low Battery                        detector supported by ZigBee Home Automation
                                                                              indication.                                                              1.2. The detector’s features are as follows:

       Panel does not arm because of an unrecognized                          Consult with your installer or system provider before                    A. Red LED
       sensor malfunction.                                                    you disable a zone. Disable the sensor zone (see                         B. Green LED
                                                                              the control panel user manual). Note that disabling
                                                                                                                                                       C. Tamper Switch
                                                                              a sensor zone lowers the overall security level of
                                                                              your system.

                                                                                                                                                         2. SPECIFICATIONS
        5. SPECIAL COMMENTS                                                                                                                               Detector Type:                                Two - Dual element low-noise pyroelectric sensor
    Even the most sophisticated detectors can sometimes be defeated or may fail to warn due to: DC power failure                                          Optical Data:                                 18 parabolic mirrors for long range
    / improper connection, malicious masking of the lens, tampering with the optical system, decreased sensitivity in                                                                                   18 parabolic mirrors for close range
    ambient temperatures close to that of the human body and unexpected failure of a component part. The above list                                       Max. Coverage:                                15 x 15 m, (49.2 x 49.2 ft) / 90°
    includes the most common reasons for failure to detect intrusion, but is by no means comprehensive. It is therefore                                   Pet Immunity:                                 Selectable: (1.No immunity 2. Up to 40 lb 3. Up to 85 lb)
    recommended that the detector and the entire alarm system be checked weekly, to ensure proper performance. An
                                                                                                                                                          ELECTRICAL
    alarm system should not be regarded as a substitute for insurance. Home and property owners or renters should be
    prudent enough to continue insuring their lives and property, even though they are protected by an alarm system.                                      Internal Batteries:                           Two 3V Lithium batteries, type CR-123A. For UL installations, use Panasonic only
                                                                                                                                                          Nominal Battery Capacity:                     1400 mAh per battery
                                                                                                                                                          Battery Life (with LED on):                   Typically over 5 years
        6. COMPLIANCE WITH STANDARDS                                                                                                                                                                    Note: Inability to connect with wireless network, or wireless link quality resulting in intermittent connection may
                                                                                                                                                                                                        significantly reduce the expected battery life.
    FCC Statement: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the            Battery Power Test:                           Performed immediately upon battery insertion and during each transmission to the panel
    FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment
    generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful          FUNCTIONAL
    interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this           Alarm Period:                                 3 seconds
    equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on,              Visual Indications:                           Red LED lights for about 3 seconds upon transmission of alarm & tamper messages and upon motion
    the user is encouraged to try to correct the interference by one of the following measures:                                                                                                         Detection in the walk test mode only (walk test mode available for approx. 15 minutes). Red LED flashes during
    •       Reorient or relocate the receiving antenna.                                                                                                                                                 the power-up stabilization period, or after restoring (pressing) the tamper switch (power-up stabilization period is
    •       Increase the separation between the equipment and receiver.                                                                                                                                 approx. 1 minutes). LED does not light upon transmissions of supervision messages or alarm detection after
    •       Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.                                                                                   termination of walk test mode.
    •       Consult the dealer or an experienced radio/TV technician for help.                                                                            Rearm Timer:                                  Rearms the detector 2 minutes after the last alarm. Timer disabled in the walk test mode.
    This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:                                             WIRELESS
    (1) This device may not cause harmful interferene and (2) this device must accept any interference received, including interference that may          Supported Network:                            ZigBee H.A 1.2
    cause undesired operation.
                                                                                                                                                          Frequency:                                    2.405 – 2.480 Ghz as per IEEE 802.15.4
    Warning: Changes or modifications not expressly approved by the Ecolink Intelligent Technology Inc. could void the user’s authority to operate        Tamper Alert:                                 Reported when a tamper event occurs and in any subsequent message, until the tamper switch is restored
    the equipment.                                                                                                                                        MOUNTING
    This device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the                                                 Height:                                       1.8-2.4 m (6 - 8 ft). For pet rejection, the optimal height is 2.1 m (7 ft)
    following two conditions: (1) this device may not cause interference, and (2) this device must accept any
                                                                                                                                                          Installation Options:                         Surface or corner
    interference, including interference that may cause undesired operation of the device.
    Cet appareil est conforme avec Industrie Canada exempts de licence standard RSS (s). Son fonctionnement est                                           ENVIRONMENTAL
    soumis aux deux conditions suivantes: (1) cet appareil ne doit pas provoquer d'interférences et (2) cet appareil                                      Operating Temperatures                        -10˚ C to 55˚ C (14˚ F to 131˚ F)
    doit accepter toute interférence, y compris celles pouvant causer un mauvais fonctionnement de l'appareil.                                            Storage Temperatures                          -20˚ C to 65˚ C (-4˚ F to 149˚ F)
    In accordance with FCC requirements of human exposure to radiofrequency fields, the radiating element shall be                                        COMPLIANCE WITH STANDARDS
    installed such that a minimum separation distance of 20 cm is maintained from the general population.                                                 USA                                           CFR 47 part 15,
    Conformément aux exigences d'Industrie Canada en matière d'exposition humaine aux champs de                                                                                                         ANSI/UL 639
    radiofréquences, l'élément rayonnant doit être installé de telle sorte qu'une distance minimale de 20 cm soit                                         PHYSICAL
    maintenue par rapport à la population générale.                                                                                                       Size (H x W x D)                              83 x 61 x 42 mm (3.27 x 2.4 x 1.66”)
    FCC ID: XQC-PIRZB1ECO                                                                                                                                 Weight (with battery)                         90 g (3.17 oz)
    IC ID: 9863B-PIRZB1ECO                                                                                                                                Color                                         White
     Installation shall be done in accordance with the Standard for Installation and Classification of Burglar and Holdup Alarm Systems, UL 681.

PN PIRZB1-ECO R1.00 Rev date 6/26/2017


          3. INSTALLATION                                                                            3.4 Activating and Pairing the Detector
                                                                                                     To pair the detector to the Touchscreen (control panel), you must set the detector to pairing mode.
     3.1 General Guidance                                             Figure 2. General Guidelines   1. First set the Touchscreen (panel) to pairing mode and then the detector.
     1.   Do not install near heating and cooling sources.                                           2. To activate, pull the activation strip that protrudes from the back of the detector.
     2.   Do not aim detector at windows due to risk of drafts.                                      3. The green LED (see Figure 1) blinks 3 times every 5 seconds (repeated up to 20 times) to indicate
     3.   Do not install outdoors.                                                                      that the detector is searching for the Touchscreen (control panel).
     4.   Do not install where direct sunlight can strike the unit.                                     Note: If detector pairing is not successful during the searching process – by pressing the tamper
                                                                                                        switch – the searching process will restart.
     5.   Do not install near high-voltage electrical lines.
     6.   Do not install behind any obstructions.                                                    4. Complete the pairing procedure on the Touchscreen (control panel). See the pairing instructions in
                                                                                                        the Touchscreen (control panel) installation guide for details..
     7.   Do not mount on unstable surfaces.
                                                                                                        Note: Pairing should be performed before installation.
                                                                                                     After the installation a good link to the panel is displayed when the Received Signal Strength
                                                                                                     Indicator (RSSI) indicated on the panel is higher than -70dBm and the Link Quality Indicator (LQI) is
                                                                                                     stronger than 250.
                                                                                                     If the RSSI and LQI values are lower, you must change the location of the detector.


                                                                                                     3.5 Rebooting the Detector
     3.2 Installation Procedure                                                                      To reboot the detector, complete the following steps:
                                                                                                     1. Remove the battery cover.
                                                                                                     2. Press and release the tamper switch (see Figure – 1) for 1 to 2 seconds.
                                                                                                     3. Close the battery cover.
     1. Separate detector from bracket. Figure 3.
     2. Remove the bracket.
     3. Mount bracket to wall using the center
        screw holes (B) or corner screw holes (A1 &                                                  3.6 Return the Detector to default mode
        A2). Figure 4.
     4. Install new batteries OR if batteries are                                                    CAUTION! The defaulting process removes the device from the network and enables re-pairing.
        installed, remove the activation strip.                                                      Prerequisite: Separate the detector from the bracket to remove both batteries.
     5. Remount the detector by sliding it down
        onto the bracket until a click is heard. Figure                                              See Figure 6 for details.
        5.                                                                                           1. Press and hold down the detectors tamper switch.
     6. The unit is ready for walk test.                                                             2. Insert one of the two batteries into the detector while observing battery polarity.
                                                                                                     3. Release the tamper switch within 4 seconds (the LED blinks 3 times every 5 seconds).
                                                                                                     4. To re-pair the detector, follow the instructions in section 3.4.
                                                                                                     Note: It is recommended to wait about 1 minute after battery removal, before inserting the new
                                                                                                     battery.


                                                                                                     3.7 Walk Testing
                                                                                                     Walk across the far end of coverage pattern in both directions. The LED should light for 2-3 seconds
     3.3 Replacing the Batteries                                                                     each time your motion is detected.

     1. Press upward to separate the detector from                                                   Important! Instruct the user to walk test at
        the bracket.                                                                                 least once a week to verify proper function of
     2. Replace the batteries.                                                                       the detector.
     3. Put back the detector on the bracket.
                                                                                                     Note: After battery insertion or closing the
     Note: It is recommended to wait                                                                 cover (which results in closing the tamper
     approximately 1 minute after battery                                                            switch)the LED flashes for 2 minutes and
     removal before inserting the new                                                                the detector goes into walk-test mode for
     battery.                                                                                        15 minutes. In walk test mode the LED lights
                                                                                                     for every motion detected. After 15 minutes
     CAUTION! Risk of explosion if                                                                   the detector automatically enters normal mode
     battery is replace by an incorrect                                                              i n which the LED will not blink after
     type. Dispose of used battery                                                                   detection.
     according to the manufacturers
     instructions.

                                                                                                                                                                     Figure 7 – Coverage Pattern Walk-Test