RF Exposure Analysis

FCC ID: XQC-FFZB1

RF Exposure Info

Download: PDF
FCCID_3013230

                                 RF Exposure Analysis

Maximum Permissive Exposure

Performance Criterion:         The human RF exposure limit is 1 mW/cm2.

Evaluation Results:            Complies

Details:       The maximum permissible exposure (MPE) is predicted by using the following
equation:

                                           S = PG/4πR2

where: S = power density (in appropriate units, e.g. mW/cm2)
       P = power input to the antenna (in appropriate units, e.g., mW)
       G = power gain of the antenna in the direction of interest relative to an isotropic radiator
       R = distance to the center of radiation of the antenna (appropriate units, e.g., cm)

P = 50.4 mW, G = 2.138 (+3.3 dBi), R = 20 cm

                                    S = 0.0214 mW/cm2 = 0.214 W/m2




FCC ID: XQC-FFZB1                      RF Exposure Analysis                               Page 1 of 1
IC: 9863B-FFZB1



Document Created: 2015-11-04 12:51:00