MDE_UBLOX_1807_FCCc_rev01-FINAL-2019-03-18

FCC ID: XPYTOBYL280

Test Report

Download: PDF
FCCID_4227285

FCC Measurement/Technical Report on

TOBY-L280 LTE/3G/2G data and
voice module
acc. to FCC Part 27 Subpart C



FCC ID: XPYTOBYL280
IC: 8595A-TOBYL280


Test Report Reference: MDE_UBLOX_1807_FCCc_rev01




 Test Laboratory:
 7layers GmbH
 Borsigstrasse 11
 40880 Ratingen
 Germany

 Note:
 The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts
 without the written approval of the test laboratory.

 7layers GmbH                       Geschäftsführer/
 Borsigstraße 11                    Managing Directors:                Registergericht/registered:                           a Bureau Veritas
 40880 Ratingen, Germany            Frank Spiller                      Düsseldorf HRB 75554                                  Group Company
 T +49 (0) 2102 749 0               Bernhard Retka                     USt-Id.-Nr./VAT-No. DE203159652
 F +49 (0) 2102 749 350             Alexandre Norré-Oudard             Steuer-Nr./TAX-No. 147/5869/0385                      www.7layers.com


 Commerzbank AG     Account No. 303 016 000   Bank Code 300 400 00   IBAN DE81 3004 0000 0303 0160 00   Swift Code COBADEFF


Table of Contents
1.1   Applied Standards                                          3
1.2   FCC-IC Correlation Table                                   4
1.3   Measurement Summary / Signatures                           5

2     Administrative Data                                       6
2.1   Testing Laboratory                                         6
2.2   Project Data                                               6
2.3   Applicant Data                                             6
2.4   Manufacturer Data                                          6

3     Test object Data                                          7
3.1   General EUT Description                                    7
3.2   EUT Main components                                        7
3.3   Ancillary Equipment                                        8
3.4   Auxiliary Equipment                                        8
3.5   EUT Setups                                                 8
3.6   Operating Modes                                            9
3.7   Product labelling                                          9

4     Test Results                                            10
4.1   RF power output                                          10

5     Test Equipment                                          20

6     Antenna Factors, Cable Loss and Sample Calculations     22
6.1   LISN R&S ESH3-Z5 (150 kHz – 30 MHz)                      22
6.2   Antenna R&S HFH2-Z2 (9 kHz – 30 MHz)                     23
6.3   Antenna R&S HL562 (30 MHz – 1 GHz)                       24
6.4   Antenna R&S HF907 (1 GHz – 18 GHz)                       25
6.5   Antenna EMCO 3160-09 (18 GHz – 26.5 GHz)                 26
6.6   Antenna EMCO 3160-10 (26.5 GHz – 40 GHz)                 27

7     Measurement Uncertainties                               28

8     Photo Report                                            28




TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01            Page 2 of 28


Applied Standards and Test Summary

1.1    APPLIED STANDARDS

Applicable FCC Rules

Prepared in accordance with the requirements of FCC Rules and Regulations as listed in 47 CFR
Ch.1 Parts 2 and 27, (10/1/16 Edition). The following subparts are applicable to the results in
this test report.


Part 27, Subpart C – Technical Standards

§ 27.50 – Power limits and duty cycle



The tests were selected and performed with reference to:

      FCC Public Notice 971168 applying “Measurement guidance for certification of licensed
       digital transmitters” 971168 D01 v03,2017-10-27

      ANSI C63.26: 2015




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                   Page 3 of 28


 Summary Test Results:

 The EUT complied with all performed tests as listed in chapter 1.3 Measurement
 Summary / Signatures.


 1.2    FCC-IC CORRELATION TABLE


 Correlation of measurement requirements for Cellular Radiotelephone
 Service from FCC and ISED Canada

Measurement                  FCC reference            ISED reference
RF Power Output              §2.1046                  RSS-GEN Issue 4, 6.12
                             §27.50                   RSS-199 Issue 3, 4.4



Field strength of spurious   §2.1053                  RSS-GEN Issue 3, 6.13
radiation                    §27.51                   RSS-199 Issue 3: 4.5




  TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                        Page 4 of 28


1.3   MEASUREMENT SUMMARY / SIGNATURES


47 CFR CHAPTER I FCC PART 27 Subpart C              §2.1046, §27.50
RF Power Output
The measurement was performed according to ANSI C63.26, KDB      Final Result
971168 DO1 v03,2017—10—27

OP—Mode                                                                Setup         FCC          IC
Frequency Band, Modulation, Channel, Frequency
LTE eFDD7, QPSK, 21100, 2535 MHz                                       So1_AAO1      Passed       Passed
LTE eFDD7, 16QAM, 21100, 2535 MHz                                      S01_AA01      Passed       Passed



47 CFR CHAPTER I FCC PART 27 Subpart C              §2.1053, §27.51
Field strength of spurious radiation
The measurement was performed according to ANSI C63.26           Final Result

OP—Mode                                                                Setup         FCC          IC
Frequency Band, Modulation, Channel, Frequency
 LTE eFDD7, QPSK, 21100, 2535 MHz                                      S01_ABOL      Passed       Passed




Revision History

                                         Report version control
 Version         Release date             Change Description                   Version validity
 initial         2019—02—21               x«                                   invalid
 revOl           2019—03—18               ISED reference changed on page 4     valid

COMMENT:
On applicants demand not all applicable tests were tested.




        (responsible for accreditation
             Dipl.—Ing. Daniel G          /
                                                                   | Npigt
                                                       ers C sp()nsibl\e/ggizxng and report)
                                                                       B.Sc. Jens Dorwald
                                              7 layers GmbH, Borsigetr. 11
                                              40880 Ratingen, Germany
                                              Phone +49 (0)2102 749 0




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_revO1                                                 Page 5 of 28


2 ADMINISTRATIVE DATA

2.1   TESTING LABORATORY
Company Name:                            7layers GmbH

Address:                                 Borsigstr. 11
                                         40880 Ratingen
                                         Germany


FCC designation number:                  DE0015

This facility has been fully described in a report submitted to the ISED and accepted under
the registration number: Site# 3699A-1.

The test facility is also accredited by the following accreditation organisation:

Laboratory accreditation no:             DAkkS D-PL-12140-01-00

Responsible for accreditation scope:     Dipl.-Ing. Daniel Gall

Report Template Version:                 2017-07-14


2.2   PROJECT DATA
Responsible for testing and report:      B.Sc. Jens Dörwald

Employees who performed the tests:       documented internally at 7Layers

Date of Report:                          2019-03-18

Testing Period:                          2018-01-15 to 2018-01-15



2.3   APPLICANT DATA
Company Name:                            u-blox AG

Address:                                 u-blox AG
                                         CH-8800 Thalwil
                                         Switzerland
Contact Person:                          Mr. Giulio Comar


2.4   MANUFACTURER DATA
Company Name:                            please see applicant data

Address:



Contact Person:




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                   Page 6 of 28


3 TEST OBJECT DATA

3.1     GENERAL EUT DESCRIPTION

Kind of Device                   GSM / UMTS and LTE module.
product description
Product name                     TOBY-L280 LTE/3G/2G data and voice module
Type                             -

Declared EUT data by the supplier

General Product                  The EUT is a GSM / UMTS and LTE module.
Description
Voltage Type                     DC
Voltage Level                    3.8 V

The main components of the EUT are listed and described in chapter 3.2 EUT Main
components.


3.2     EUT MAIN COMPONENTS

Sample Name                       Sample Code                                  Description
DE1015015                         ab01                                         radiated & conducted sample
  Sample Parameter                                                        Value
Serial Number                     358503060599298
HW Version                        217B00
SW Version                        v16.16
Comment                           -

NOTE:The short description is used to simplify the identification of the EUT in this test report.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                                   Page 7 of 28


3.3      ANCILLARY EQUIPMENT

For the purposes of this test report, ancillary equipment is defined as equipment which is used
in conjunction with the EUT to provide operational and control features to the EUT. It is
necessary to configure the system in a typical fashion, as a customer would normally use it.
But nevertheless Ancillary Equipment can influence the test results.

Device                       Details                                       Description
                             (Manufacturer, Type Model, OUT
                             Code)
-                            -                                             -


3.4      AUXILIARY EQUIPMENT

For the purposes of this test report, auxiliary equipment is defined as equipment which is used
temporarily to enable operational and control features especially used for the tests of the EUT
which is not used during normal operation or equipment that is used during the tests in
combination with the EUT but is not subject of this test report. It is necessary to configure the
system in a typical fashion, as a customer would normally use it.
But nevertheless Auxiliary Equipment can influence the test results.

Device                        Details                                      Description
                              (Manufacturer, HW, SW, S/N)
AUX1                          UBLOX, EVB-WL3, -, -                         Evaluation board

AUX2                          Taoglas, -, -, -                             External Cellular
                                                                           Antenna



3.5      EUT SETUPS

This chapter describes the combination of EUTs and equipment used for testing. The rationale
for selecting the EUTs, ancillary and auxiliary equipment and interconnecting cables, is to test
a representative configuration meeting the requirements of the referenced standards.

      Setup     Combination of EUTs                    Description and Rationale
    S01_AA01       ab01 + AUX1                         Setup for conducted tests
    S01_AB01    ab01 + AUX1 + AUX2                      Setup for radiated tests




    TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                      Page 8 of 28


3.6   OPERATING MODES
This chapter describes the operating modes of the EUTs used for testing.

3.6.1 TEST CHANNELS

                                                                  Center
                                                                Frequency
                   Band              Uplink Channel               [MHz]
                  eFDD 7                  21100                    2535




3.7   PRODUCT LABELLING

3.7.1 FCC ID LABEL
Please refer to the documentation of the applicant.


3.7.2 LOCATION OF THE LABEL ON THE EUT
Please refer to the documentation of the applicant.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                           Page 9 of 28


4 TEST RESULTS

4.1   RF POWER OUTPUT

Standard      FCC Part 27, §27.50

The test was performed according to:
ANSI C63.26, KDB 935210 D05 v01r01: 3.5

4.1.1 TEST DESCRIPTION

The EUT was connected to the test setup according to the following diagram:




The attenuation of the measuring and stimulus path are known for each measured frequency
and are considered.

The Spectrum Analyzer settings can be directly found in the measurement diagrams.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                              Page 10 of 28


4.1.2 TEST REQUIREMENTS / LIMITS

§2,0146 Measurements Required: RF Power Output

 (a) For transmitters other than single sideband, independent sideband and controlled carrier
radiotelephone, power output shall be measured at the RF output terminals when the
transmitter is adjusted in accordance with the tune-up procedure to give the values of current
and voltage on the circuit elements specified in §2.1033(c)(8). The electrical characteristics of
the radio frequency load attached to the output terminals when this test is made shall be
stated.



FCC Part 27, § 27.50

(h) The following power limits shall apply in the BRS and EBS:

(1) Main, booster and base stations. (i) The maximum EIRP of a main, booster or base station
shall not exceed 33 dBW + 10log(X/Y) dBW, where X is the actual channel width in MHz and Y
is either 6 MHz if prior to transition or the station is in the MBS following transition or 5.5 MHz
if the station is in the LBS and UBS following transition, except as provided in paragraph
(h)(1)(ii) of this section.

(ii) If a main or booster station sectorizes or otherwise uses one or more transmitting antennas
with a non-omnidirectional horizontal plane radiation pattern, the maximum EIRP in dBW in a
given direction shall be determined by the following formula: EIRP = 33 dBW + 10 log(X/Y)
dBW + 10 log(360/beamwidth) dBW, where X is the actual channel width in MHz, Y is either (i)
6 MHz if prior to transition or the station is in the MBS following transition or (ii) 5.5 MHz if the
station is in the LBS and UBS following transition, and beamwidth is the total horizontal plane
beamwidth of the individual transmitting antenna for the station or any sector measured at the
half-power points.

(2) Mobile and other user stations. Mobile stations are limited to 2.0 watts EIRP. All user
stations are limited to 2.0 watts transmitter output power.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                       Page 11 of 28


4.1.3 TEST PROTOCOL

                                                                                   RMS

                                                  Ressource                      Conducted
    Radio Technology               CH                          Bandwidth (MHz)
                                                   Blocks
                                                                                  Power
                                                                                  (dBm)
       eFDD 7 QPSK                mid                  1              5            21.83
       eFDD 7 QPSK                mid                 12              5            20.6
       eFDD 7 QPSK                mid                 25              5            20.56
      eFDD 7 16QAM                mid                  1              5            20.77
      eFDD 7 16QAM                mid                 25              5            19.65
       eFDD 7 QPSK                mid                  1             10            21.93
       eFDD 7 QPSK                mid                 50             10            20.90
      eFDD 7 16QAM                mid                  1             10            20.93

      eFDD 7 16QAM                mid                 50             10            20.00
       eFDD 7 QPSK                mid                  1             15            21.87
       eFDD 7 QPSK                mid                 36             15            20.94

       eFDD 7 QPSK                mid                 75             15            20.90
      eFDD 7 16QAM                mid                  1             15            20.89
      eFDD 7 16QAM                mid                 75             15            19.98
       eFDD 7 QPSK                mid                  1             20            21.85
       eFDD 7 QPSK                mid                100             20            21.00
      eFDD 7 16QAM                mid                  1             20            20.89
      eFDD 7 16QAM                mid                100             20            20.13

Remark: Please see next sub-clause for the measurement plot.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                  Page 12 of 28


4.1.4 MEASUREMENT PLOT (SHOWING THE HIGHEST VALUE, “WORST CASE”)

                Frequency Band = eFDD7 QPSK 21100 10 MHz 1 RB, Channel = mid

                        Marker 1 [T1]                   RBW   200 kHz     RF Att      20 dB

        Ref Lvl                         21.15 dBm       VBW     1 MHz
         36.5 dBm                  2.53510020 GHz       SWT   8.5 ms      Unit            dBm
 36.5
          26.5 dB Offset                                         1 [T1]            21.15 dBm
                                                                                                A
   30                                                                      2.53510020 GHz
                                                                CH PWR             21.93 dBm
                                                    1
                                                                CH BW      9.06000000 MHz SGL
   20




   10


        1VIEW                                                                                   1RM
    0




  -10                                                                                           EXT




  -20




  -30



  -40



  -50


                                                                   C0
                              C0
  -60
-63.5
        Start 2.525 GHz                        2 MHz/                      Stop 2.545 GHz

Date:           27.NOV.2018    10:08:45




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                     Page 13 of 28


4.2   FIELD STRENGTH OF SPURIOUS RADIATION

Standard      FCC Part 2.1051

The test was performed according to:
ANSI C63.26

4.2.1 TEST DESCRIPTION

This test case is intended to demonstrate compliance to the applicable radiated spurious
emission measurements per § 2.1053

The EUT was connected to the test setup according to the following diagram:




The test set-up was made in accordance to the general provisions of ANSI C63.4 in a typical
installation configuration. The Equipment Under Test (EUT) was set up on a non-conductive
table 1.0 x 2.0 m² in the semi-anechoic chamber. The influence of the EUT support table that
is used between 30–1000 MHz was evaluated.
The measurement procedure is implemented into the EMI test software EMC32 from R&S.
Exploratory tests are performed at 3 orthogonal axes to determine the worst-case orientation
of a body-worn or handheld EUT. The final test on all kind of EUTs is also performed at 3 axes.
A pre-check is performed while the EUT is powered from a DC power source.

1. Measurement above 30 MHz and up to 1 GHz

Step 1: Preliminary scan
This is a preliminary test to identify the highest amplitudes relative to the limit.
Settings for step 1:
- Antenna distance: 3 m
- Detector: Peak-Maxhold / Quasipeak (FFT-based)
- Frequency range: 30 – 1000 MHz

 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                      Page 14 of 28


- Frequency steps: 30 kHz
- IF–Bandwidth: 120 kHz
- Measuring time / Frequency step: 100 ms
- Turntable angle range: –180° to 90°
- Turntable step size: 90°
- Height variation range: 1 – 3 m
- Height variation step size: 2 m
- Polarisation: Horizontal + Vertical
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.

Step 2: Adjustment measurement
In this step the accuracy of the turntable azimuth and antenna height will be improved. This is
necessary to find out the maximum value of every frequency.
For each frequency, which was determined the turntable azimuth and antenna height will be
adjusted. The turntable azimuth will slowly vary by ± 45° around this value. During this action,
the value of emission is continuously measured. The turntable azimuth at the highest emission
will be recorded and adjusted. In this position, the antenna height will also slowly vary by ±
100 cm around the antenna height determined. During this action, the value of emission is
also continuously measured. The antenna height of the highest emission will also be recorded
and adjusted.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: ± 45 ° around the determined value
- Height variation range: ± 100 cm around the determined value
- Antenna Polarisation: max. value determined in step 1

Step 3: Final measurement with QP detector
With the settings determined in step 3, the final measurement will be performed:
EMI receiver settings for step 4:
- Detector: Quasi-Peak (< 1 GHz)
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 1 s

After the measurement a plot will be generated which contains a diagram with the results of
the preliminary scan and a chart with the frequencies and values of the results of the final
measurement.

3. Measurement above 1 GHz
The following modifications apply to the measurement procedure for the frequency range
above 1 GHz:
Step 1:
The Equipment Under Test (EUT) was set up on a non-conductive support (tilt device) at 1.5 m
height in the fully-anechoic chamber.
All steps were performed with one height (1.5 m) of the receiving antenna only.
The EUT is turned during the preliminary measurement across the elevation axis, with a step
size of 90 °.
The turn table step size (azimuth angle) for the preliminary measurement is 45 °.
Step 2:
Due to the fact, that in this frequency range the test is performed in a fully anechoic room, the
height scan of the receiving antenna instep 2 is omitted. Instead of this, a maximum search
with a step size ± 45° for the elevation axis is performed.

 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                    Page 15 of 28


The turn table azimuth will slowly vary by ± 22.5°.
The elevation angle will slowly vary by ± 45°
EMI receiver settings (for all steps):
- Detector: Peak, Average
- IF Bandwidth = 1 MHz
Step 3:
Spectrum analyser settings for step 3:
- Detector: Peak / Average
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 1 MHz
- Measuring time: 1 s



4.2.2 TEST REQUIREMENTS / LIMITS

FCC Part 2.1051; Measurement required: Spurious emissions at antenna terminal:

The radio frequency voltage or powers generated within the equipment and appearing on a
spurious frequency shall be checked at the equipment output terminals when properly loaded
with a suitable artificial antenna. Curves or equivalent data shall show the magnitude of each
harmonic and other spurious emission that can be detected when the equipment is operated
under the conditions specified in §2.1049 as appropriate. The magnitude of spurious emissions
which are attenuated more than 20 dB below the permissible value need not be specified.


Part 27, Subpart C – Technical Standards

§ 27.53m – Emission limits

(4) For mobile digital stations, the attenuation factor shall be not less than 40 + 10 log (P) dB
on all frequencies between the channel edge and 5 megahertz from the channel edge, 43 + 10
log (P) dB on all frequencies between 5 megahertz and X megahertz from the channel edge,
and 55 + 10 log (P) dB on all frequencies more than X megahertz from the channel edge,
where X is the greater of 6 megahertz or the actual emission bandwidth as defined in
paragraph (m)(6) of this section. In addition, the attenuation factor shall not be less that 43 +
10 log (P) dB on all frequencies between 2490.5 MHz and 2496 MHz and 55 + 10 log (P) dB at
or below 2490.5 MHz. Mobile Satellite Service licensees operating on frequencies below 2495
MHz may also submit a documented interference complaint against BRS licensees operating on
channel BRS Channel 1 on the same terms and conditions as adjacent channel BRS or EBS
licensees.


(6) Measurement procedure. Compliance with these rules is based on the use of measurement
instrumentation employing a resolution bandwidth of 1 megahertz or greater. However, in the
1 MHz bands immediately outside and adjacent to the frequency block a resolution bandwidth
of at least one percent of the emission bandwidth of the fundamental emission of the
transmitter may be employed; for mobile digital stations, in the 1 megahertz bands
immediately outside and adjacent to the frequency block a resolution bandwidth of at least two
percent may be employed, except when the 1 megahertz band is 2495-2496 MHz, in which
case a resolution bandwidth of at least one percent may be employed. A narrower resolution
bandwidth is permitted in all cases to improve measurement accuracy provided the measured
power is integrated over the full required measurement bandwidth (i.e. 1 megahertz or 1
percent of emission bandwidth, as specified; or 1 megahertz or 2 percent for mobile digital
stations, except in the band 2495-2496 MHz). The emission bandwidth is defined as the width

 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                    Page 16 of 28


of the signal between two points, one below the carrier center frequency and one above the
carrier center frequency, outside of which all emissions are attenuated at least 26 dB below the
transmitter power. With respect to television operations, measurements must be made of the
separate visual and aural operating powers at sufficiently frequent intervals to ensure
compliance with the rules.

RSS-139; 6.6 Transmitter Unwanted Emissions
(i)
In the first 1.0 MHz bands immediately outside and adjacent to the equipment’s smallest
operating frequency block,2 which can contain the equipment’s occupied bandwidth, the
emission power per any 1% of the emission bandwidth shall be attenuated below the
transmitter output power P (in dBW) by at least 43 + 10 log10 p (watts) dB.

(ii)
After the first 1.0 MHz outside the equipment’s smallest operating frequency block, which can
contain the equipment’s occupied bandwidth, the emission power in any 1 MHz bandwidth shall
be attenuated below the transmitter output power P (in dBW) by at least 43 + 10 log10 p
(watts) dB.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                  Page 17 of 28


4.2.3 TEST PROTOCOL

 eFDD 7, Test Frequency = mid
     Spurious              Spurious                                               Margin to
      Freq.                  Level                             RBW      Limit       Limit
      [MHz]                 [dBm]              Detector        [kHz]   [dBm]        [dB]
        -                      -                  -              -      -25.0       ---
Remark: Please see next sub-clause for the measurement plot.


COMMENT:
No (further) spurious emissions in the range 20dB below the limit were found, therefore no
measurement values are reported in the tables.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                 Page 18 of 28


4.2.4 MEASUREMENT PLOT (SHOWING THE HIGHEST VALUE, “WORST CASE”)
                                       Frequency Band = eFDD 7, Test Frequency = mid

                       0


                      -10



                      -20
                                                                                                                     FCC_27.4_e FDD7

                      -30
       Level in dBm




                      -40


                      -50



                      -60


                      -70




                       30M        50    60        80   100M                     200          300         400   500      800      1G

                                                                   Frequency in Hz


30 MHz - 1 GHz



                        0

                       -10

                       -20

                       -30

                       -40
       Level in dBm




                       -50

                       -60

                       -70

                       -80

                       -90

                      -100


                            1G               2G        3G     4G         5G          6   8         10G               20G        26G

                                                                   Frequency in Hz


1 GHz – 26 GHz

4.2.5 TEST EQUIPMENT USED
   -                  Radio Lab




TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                                                      Page 19 of 28


5 TEST EQUIPMENT
1       Radio Lab
        FCC22/24/27 cond. Test Lab

Ref.No. Device Name Description           Manufacturer       Serial Number       Last    Calibration
                                                                             Calibration     Due
1.1     FSIQ           Spectrum         Rohde & Schwarz      840061/005      2017-05     2019-05
                       Analyzer
1.2     WA1515         Broadband                             A856
                       Power Divider
                       SMA
1.3     SMA Attenuator Coax             Weinschel            F9401
        4T-10          Attenuator       Associates
                       10dB SMA 2W
1.4     SMA Attenuator Coax             Weinschel            W3702
        56-10          Attenuator       Associates
                       10dB SMA 2W
1.5     SMA Attenuator Coax             Weinschel            W3711
        56-10          Attenuator       Associates
                       10dB SMA 2W
1.6     Coax Cable     Coax Cable       Huber&Suhner         -
        Sucotest 2.0m
1.7     Coax Cable     Coax Cable       Rosenberger          544912
        Micro Coax     FA210A00100
        SMA/SMA 1.0m 03030

2       Radiated Emissions
        Lab to perform radiated emission tests

Ref.No. Device Name Description           Manufacturer       Serial Number       Last    Calibration
                                                                             Calibration     Due
2.1     NRV-Z1         Sensor Head A    Rohde & Schwarz      827753/005      2018-07     2019-07
2.2     MFS            Rubidium         Datum GmbH           002             2018-10     2020-10
                       Frequency
                       Normal MFS
2.3     Opus10 TPR     ThermoAirpres    Lufft Mess- und   13936              2017-04     2019-04
        (8253.00)      sure             Regeltechnik GmbH
                       Datalogger 13
                       (Environ)
2.4     Anechoic       10.58 x 6.38 x   Frankonia            none            2016-05     2019-05
        Chamber        6.00 m³
2.5     HL 562         Ultralog new     Rohde & Schwarz      830547/003      2018-07     2021-07
                       biconicals
2.6     5HC2700/12750 High Pass         Trilithic            9942012
        -1.5-KK        Filter
2.7     ASP 1.2/1.8-10 Antenna Mast     Maturo GmbH          -
        kg
2.8     Fully Anechoic 8.80m x          Albatross Projects   P26971-647-001- 2018-06     2020-06
        Room           4.60m x                               PRB
                       4.05m (l x w x
                       h)
2.9     Fluke 177      Digital          Fluke Europe B.V.    86670383        2018-04     2020-04
                       Multimeter 03
                       (Multimeter)
2.10    JS4-18002600- Broadband         Miteq                849785
        32-5P          Amplifier 18
                       GHz - 26 GHz
2.11    FSW 43         Spectrum         Rohde & Schwarz      103779          2016-12     2018-12
                       Analyzer

 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                      Page 20 of 28


Ref.No. Device Name Description          Manufacturer       Serial Number        Last    Calibration
                                                                             Calibration     Due
2.12    3160-09           Standard Gain EMCO Elektronic     00083069
                          / Pyramidal    GmbH
                          Horn Antenna
                          26.5 GHz
2.13    WHKX 7.0/18G-     High Pass      Wainwright         09
        8SS               Filter
2.14    4HC1600/12750     High Pass      Trilithic          9942011
        -1.5-KK           Filter
2.15    Chroma 6404       AC Power       Chroma ATE INC.    64040001304
                          Source
2.16    JS4-00102600-     Broadband      Miteq              619368
        42-5A             Amplifier 30
                          MHz - 26 GHz
2.17    TT 1.5 WI         Turn Table     Maturo GmbH        -
2.18    HL 562 Ultralog   Log.-per.      Rohde & Schwarz    100609           2016-04     2019-04
                          Antenna
2.19    3160-10           Standard Gain EMCO Elektronic     00086675
                          / Pyramidal    GmbH
                          Horn Antenna
                          40 GHz
2.20    5HC3500/18000     High Pass      Trilithic          200035008
        -1.2-KK           Filter
2.21    HFH2-Z2           Loop Antenna Rohde & Schwarz      829324/006
2.22    Opus10 THI        ThermoHygro Lufft Mess- und       12482            2017-03     2019-03
        (8152.00)         Datalogger 12 Regeltechnik GmbH
                          (Environ)
2.23    ESR 7             EMI Receiver / Rohde & Schwarz    101424           2016-11     2018-11
                          Spectrum
                          Analyzer
2.24    JS4-00101800-     Broadband      Miteq              896037
        35-5P             Amplifier 30
                          MHz - 18 GHz
2.25    AS 620 P          Antenna mast HD GmbH              620/37
2.26    Tilt device       Antrieb TD1.5- Maturo GmbH        TD1.5-
        Maturo            10kg                              10kg/024/37907
        (Rohacell)                                          09
2.27    ESIB 26         Spectrum     Rohde & Schwarz        830482/004
                        Analyzer
2.28    PAS 2.5 - 10 kg Antenna Mast Maturo GmbH            -
2.29    AM 4.0          Antenna mast Maturo GmbH            AM4.0/180/1192
                                                            0513
2.30    HF 907            Double-ridged Rohde & Schwarz     102444         2018-07       2021-07
                          horn
The calibration interval is the time interval between “Last Calibration” and “Calibration Due”




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                      Page 21 of 28


6 ANTENNA FACTORS, CABLE LOSS AND SAMPLE CALCULATIONS
This chapter contains the antenna factors with their corresponding path loss of the used
measurement path for all antennas as well as the insertion loss of the LISN.



6.1    LISN R&S ESH3-Z5 (150 KHZ – 30 MHZ)
                                                         cable
                                              LISN        loss
                                           insertion   (incl. 10
                                              loss         dB
                                             ESH3-      atten-
  Frequency                 Corr.              Z5       uator)
     MHz                     dB                dB          dB
       0.15                   10.1               0.1        10.0
          5                   10.3               0.1        10.2
          7                   10.5               0.2        10.3
         10                   10.5               0.2        10.3
         12                   10.7               0.3        10.4
         14                   10.7               0.3        10.4
         16                   10.8               0.4        10.4
         18                   10.9               0.4        10.5
         20                   10.9               0.4        10.5
         22                   11.1               0.5        10.6
         24                   11.1               0.5        10.6
         26                   11.2               0.5        10.7
         28                   11.2               0.5        10.7
         30                   11.3               0.5        10.8

Sample calculation

  ULISN (dB µV) = U (dB µV) + Corr. (dB)
  U = Receiver reading
  LISN Insertion loss = Voltage Division Factor of LISN
  Corr. = sum of single correction factors of used LISN, cables, switch units (if used)
  Linear interpolation will be used for frequencies in between the values in the table.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                         Page 22 of 28


6.2    ANTENNA R&S HFH2-Z2 (9 KHZ – 30 MHZ)
                                              cable        cable        cable        cable     distance     dLimit      dused
                                              loss 1       loss 2      loss 3       loss 4       corr.     (meas.      (meas.
                  AF                         (inside      (outside    (switch         (to      (-40 dB/   distance    distance
  Frequency    HFH-Z2)       Corr.          chamber)     chamber)       unit)     receiver)    decade)     (limit)     (used)
     MHz       dB (1/m)       dB                dB           dB          dB           dB          dB          m          m
      0.009      20.50        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.01      20.45        -79.6                0.1          0.1         0.1          0.1        -80        300            3
      0.015      20.37        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.02      20.36        -79.6                0.1          0.1         0.1          0.1        -80        300            3
      0.025      20.38        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.03      20.32        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.05      20.35        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.08      20.30        -79.6                0.1          0.1         0.1          0.1        -80        300            3
        0.1      20.20        -79.6                0.1          0.1         0.1          0.1        -80        300            3
        0.2      20.17        -79.6                0.1          0.1         0.1          0.1        -80        300            3
        0.3      20.14        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.49      20.12        -79.6                0.1          0.1         0.1          0.1        -80        300            3
   0.490001      20.12        -39.6                0.1          0.1         0.1          0.1        -40          30           3
        0.5      20.11        -39.6                0.1          0.1         0.1          0.1        -40          30           3
        0.8      20.10        -39.6                0.1          0.1         0.1          0.1        -40          30           3
          1      20.09        -39.6                0.1          0.1         0.1          0.1        -40          30           3
          2      20.08        -39.6                0.1          0.1         0.1          0.1        -40          30           3
          3      20.06        -39.6                0.1          0.1         0.1          0.1        -40          30           3
          4      20.05        -39.5                0.2          0.1         0.1          0.1        -40          30           3
          5      20.05        -39.5                0.2          0.1         0.1          0.1        -40          30           3
          6      20.02        -39.5                0.2          0.1         0.1          0.1        -40          30           3
          8      19.95        -39.5                0.2          0.1         0.1          0.1        -40          30           3
         10      19.83        -39.4                0.2          0.1         0.2          0.1        -40          30           3
         12      19.71        -39.4                0.2          0.1         0.2          0.1        -40          30           3
         14      19.54        -39.4                0.2          0.1         0.2          0.1        -40          30           3
         16      19.53        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         18      19.50        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         20      19.57        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         22      19.61        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         24      19.61        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         26      19.54        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         28      19.46        -39.2                0.3          0.1         0.3          0.1        -40          30           3
         30      19.73        -39.1                0.4          0.1         0.3          0.1        -40          30           3

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  distance correction = -40 * LOG (dLimit/ dused)
  Linear interpolation will be used for frequencies in between the values in the table.
  Table shows an extract of values




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                                           Page 23 of 28


6.3    ANTENNA R&S HL562 (30 MHZ – 1 GHZ)
(dLimit = 3 m)
                                              cable       cable         cable       cable     distance     dLimit       dused
                    AF                        loss 1      loss 2       loss 3      loss 4       corr.     (meas.       (meas.
                   R&S                       (inside     (outside     (switch        (to      (-20 dB/   distance     distance
  Frequency       HL562      Corr.          chamber)    chamber)        unit)    receiver)    decade)     (limit)      (used)
     MHz         dB (1/m)     dB                dB          dB           dB          dB          dB          m           m
         30          18.6       0.6              0.29        0.04         0.23         0.02        0.0            3           3
         50           6.0       0.9              0.39        0.09         0.32         0.08        0.0            3           3
        100           9.7       1.2              0.56        0.14         0.47         0.08        0.0            3           3
        150           7.9       1.6              0.73        0.20         0.59         0.12        0.0            3           3
        200           7.6       1.9              0.84        0.21         0.70         0.11        0.0            3           3
        250           9.5       2.1              0.98        0.24         0.80         0.13        0.0            3           3
        300          11.0       2.3              1.04        0.26         0.89         0.15        0.0            3           3
        350          12.4       2.6              1.18        0.31         0.96         0.13        0.0            3           3
        400          13.6       2.9              1.28        0.35         1.03         0.19        0.0            3           3
        450          14.7       3.1              1.39        0.38         1.11         0.22        0.0            3           3
        500          15.6       3.2              1.44        0.39         1.20         0.19        0.0            3           3
        550          16.3       3.5              1.55        0.46         1.24         0.23        0.0            3           3
        600          17.2       3.5              1.59        0.43         1.29         0.23        0.0            3           3
        650          18.1       3.6              1.67        0.34         1.35         0.22        0.0            3           3
        700          18.5       3.6              1.67        0.42         1.41         0.15        0.0            3           3
        750          19.1       4.1              1.87        0.54         1.46         0.25        0.0            3           3
        800          19.6       4.1              1.90        0.46         1.51         0.25        0.0            3           3
        850          20.1       4.4              1.99        0.60         1.56         0.27        0.0            3           3
        900          20.8       4.7              2.14        0.60         1.63         0.29        0.0            3           3
        950          21.1       4.8              2.22        0.60         1.66         0.33        0.0            3           3
       1000          21.6       4.9              2.23        0.61         1.71         0.30        0.0            3           3


(dLimit = 10 m)
           30       18.6        -9.9             0.29         0.04        0.23        0.02       -10.5          10           3
           50        6.0        -9.6             0.39         0.09        0.32        0.08       -10.5          10           3
          100        9.7        -9.2             0.56         0.14        0.47        0.08       -10.5          10           3
          150        7.9        -8.8             0.73         0.20        0.59        0.12       -10.5          10           3
          200        7.6        -8.6             0.84         0.21        0.70        0.11       -10.5          10           3
          250        9.5        -8.3             0.98         0.24        0.80        0.13       -10.5          10           3
          300       11.0        -8.1             1.04         0.26        0.89        0.15       -10.5          10           3
          350       12.4        -7.9             1.18         0.31        0.96        0.13       -10.5          10           3
          400       13.6        -7.6             1.28         0.35        1.03        0.19       -10.5          10           3
          450       14.7        -7.4             1.39         0.38        1.11        0.22       -10.5          10           3
          500       15.6        -7.2             1.44         0.39        1.20        0.19       -10.5          10           3
          550       16.3        -7.0             1.55         0.46        1.24        0.23       -10.5          10           3
          600       17.2        -6.9             1.59         0.43        1.29        0.23       -10.5          10           3
          650       18.1        -6.9             1.67         0.34        1.35        0.22       -10.5          10           3
          700       18.5        -6.8             1.67         0.42        1.41        0.15       -10.5          10           3
          750       19.1        -6.3             1.87         0.54        1.46        0.25       -10.5          10           3
          800       19.6        -6.3             1.90         0.46        1.51        0.25       -10.5          10           3
          850       20.1        -6.0             1.99         0.60        1.56        0.27       -10.5          10           3
          900       20.8        -5.8             2.14         0.60        1.63        0.29       -10.5          10           3
          950       21.1        -5.6             2.22         0.60        1.66        0.33       -10.5          10           3
         1000       21.6        -5.6             2.23         0.61        1.71        0.30       -10.5          10           3

Sample calculation
  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  distance correction = -20 * LOG (dLimit/ dused)
  Linear interpolation will be used for frequencies in between the values in the table.
  Tables show an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                                          Page 24 of 28


6.4    ANTENNA R&S HF907 (1 GHZ – 18 GHZ)
                                                                       cable
                                               cable                   loss 3
                                              loss 1                  (switch
                                             (relay +      cable        unit,
                  AF                           cable       loss 2     atten-        cable
                 R&S                          inside      (outside    uator &     loss 4 (to
  Frequency     HF907        Corr.          chamber)     chamber)    pre-amp)     receiver)
     MHz       dB (1/m)       dB                dB           dB          dB           dB
       1000        24.4       -19.4               0.99        0.31      -21.51         0.79
       2000        28.5       -17.4               1.44        0.44      -20.63         1.38
       3000        31.0       -16.1               1.87        0.53      -19.85         1.33
       4000        33.1       -14.7               2.41        0.67      -19.13         1.31
       5000        34.4       -13.7               2.78        0.86      -18.71         1.40
       6000        34.7       -12.7               2.74        0.90      -17.83         1.47
       7000        35.6       -11.0               2.82        0.86      -16.19         1.46

                                                                                    cable
                                                                                    loss 4
                                               cable                               (switch
                                              loss 1       cable       cable         unit,                  used
                  AF                          (relay       loss 2      loss 3      atten-        cable      for
                 R&S                          inside      (inside     (outside     uator &     loss 5 (to   FCC
  Frequency     HF907        Corr.          chamber)     chamber)    chamber)     pre-amp)     receiver)    15.247
     MHz       dB (1/m)       dB                dB           dB          dB           dB           dB
       3000        31.0       -23.4               0.47        1.87        0.53       -27.58         1.33
       4000        33.1       -23.3               0.56        2.41        0.67       -28.23         1.31
       5000        34.4       -21.7               0.61        2.78        0.86       -27.35         1.40
       6000        34.7       -21.2               0.58        2.74        0.90       -26.89         1.47
       7000        35.6       -19.8               0.66        2.82        0.86       -25.58         1.46

                                               cable
                                              loss 1      cable        cable        cable        cable         cable
                  AF                          (relay      loss 2       loss 3       loss 4       loss 5       loss 6
                 R&S                          inside      (High         (pre-      (inside      (outside        (to
  Frequency     HF907        Corr.          chamber)      Pass)        amp)       chamber)     chamber)     receiver)
     MHz       dB (1/m)       dB                dB          dB            dB          dB           dB           dB
       7000        35.6       -57.3               0.56       1.28        -62.72        2.66         0.94          1.46
       8000        36.3       -56.3               0.69       0.71        -61.49        2.84         1.00          1.53
       9000        37.1       -55.3               0.68       0.65        -60.80        3.06         1.09          1.60
      10000        37.5       -56.2               0.70       0.54        -61.91        3.28         1.20          1.67
      11000        37.5       -55.3               0.80       0.61        -61.40        3.43         1.27          1.70
      12000        37.6       -53.7               0.84       0.42        -59.70        3.53         1.26          1.73
      13000        38.2       -53.5               0.83       0.44        -59.81        3.75         1.32          1.83
      14000        39.9       -56.3               0.91       0.53        -63.03        3.91         1.40          1.77
      15000        40.9       -54.1               0.98       0.54        -61.05        4.02         1.44          1.83
      16000        41.3       -54.1               1.23       0.49        -61.51        4.17         1.51          1.85
      17000        42.8       -54.4               1.36       0.76        -62.36        4.34         1.53          2.00
      18000        44.2       -54.7               1.70       0.53        -62.88        4.41         1.55          1.91

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  Linear interpolation will be used for frequencies in between the values in the table.
  Tables show an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                                           Page 25 of 28


6.5    ANTENNA EMCO 3160-09 (18 GHZ – 26.5 GHZ)
                                              cable        cable      cable         cable       cable
                  AF                          loss 1      loss 2      loss 3       loss 4      loss 5
                EMCO                         (inside       (pre-     (inside      (switch        (to
  Frequency    3160-09       Corr.          chamber)      amp)      chamber)        unit)    receiver)
     MHz       dB (1/m)       dB                dB          dB          dB           dB          dB
      18000        40.2       -23.5              0.72      -35.85        6.20         2.81         2.65
      18500        40.2       -23.2              0.69      -35.71        6.46         2.76         2.59
      19000        40.2       -22.0              0.76      -35.44        6.69         3.15         2.79
      19500        40.3       -21.3              0.74      -35.07        7.04         3.11         2.91
      20000        40.3       -20.3              0.72      -34.49        7.30         3.07         3.05
      20500        40.3       -19.9              0.78      -34.46        7.48         3.12         3.15
      21000        40.3       -19.1              0.87      -34.07        7.61         3.20         3.33
      21500        40.3       -19.1              0.90      -33.96        7.47         3.28         3.19
      22000        40.3       -18.7              0.89      -33.57        7.34         3.35         3.28
      22500        40.4       -19.0              0.87      -33.66        7.06         3.75         2.94
      23000        40.4       -19.5              0.88      -33.75        6.92         3.77         2.70
      23500        40.4       -19.3              0.90      -33.35        6.99         3.52         2.66
      24000        40.4       -19.8              0.88      -33.99        6.88         3.88         2.58
      24500        40.4       -19.5              0.91      -33.89        7.01         3.93         2.51
      25000        40.4       -19.3              0.88      -33.00        6.72         3.96         2.14
      25500        40.5       -20.4              0.89      -34.07        6.90         3.66         2.22
      26000        40.5       -21.3              0.86      -35.11        7.02         3.69         2.28
      26500        40.5       -21.1              0.90      -35.20        7.15         3.91         2.36

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  Linear interpolation will be used for frequencies in between the values in the table.
  Table shows an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                                          Page 26 of 28


6.6    ANTENNA EMCO 3160-10 (26.5 GHZ – 40 GHZ)
                                              cable        cable        cable       cable    distance      dLimit       dused
                  AF                          loss 1       loss 2      loss 3      loss 4      corr.      (meas.       (meas.
                EMCO                         (inside      (outside    (switch        (to     (-20 dB/    distance     distance
  Frequency    3160-10       Corr.          chamber)     chamber)       unit)    receiver)   decade)      (limit)      (used)
     GHz       dB (1/m)       dB                dB           dB          dB          dB         dB           m           m
       26.5        43.4       -11.2                4.4                                          -15.6             3         0.5
       27.0        43.4       -11.2                4.4                                          -15.6             3         0.5
       28.0        43.4       -11.1                4.5                                          -15.6             3         0.5
       29.0        43.5       -11.0                4.6                                          -15.6             3         0.5
       30.0        43.5       -10.9                4.7                                          -15.6             3         0.5
       31.0        43.5       -10.8                4.7                                          -15.6             3         0.5
       32.0        43.5       -10.7                4.8                                          -15.6             3         0.5
       33.0        43.6       -10.7                4.9                                          -15.6             3         0.5
       34.0        43.6       -10.6                5.0                                          -15.6             3         0.5
       35.0        43.6       -10.5                5.1                                          -15.6             3         0.5
       36.0        43.6       -10.4                5.1                                          -15.6             3         0.5
       37.0        43.7       -10.3                5.2                                          -15.6             3         0.5
       38.0        43.7       -10.2                5.3                                          -15.6             3         0.5
       39.0        43.7       -10.2                5.4                                          -15.6             3         0.5
       40.0        43.8       -10.1                5.5                                          -15.6             3         0.5

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  Linear interpolation will be used for frequencies in between the values in the table.
  distance correction = -20 * LOG (dLimit/ dused)
  Linear interpolation will be used for frequencies in between the values in the table.
  Table shows an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                                                          Page 27 of 28


7 MEASUREMENT UNCERTAINTIES

   Test Case(s)                                 Parameter   Uncertainty
   -   Field strength of spurious radiation     Power       ± 5.5 dB


   -   Out-of-band rejection                    Power       ± 2.9 dB
   -   Occupied Bandwidth                       Frequency   ± 11.2 kHz
   -   Input versus output spectrum


   -   Effective radiated power, mean output    Power       ± 2.2 dB
       power and zone enhancer gain
   -   Peak to Average Ratio


   -   Out-of-band emission limits              Power       ± 2.2 dB
   -   Conducted Spurious Emissions at          Frequency   ± 11.2 kHz
       Antenna Terminal




8 PHOTO REPORT

Please see separate photo report.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCc_rev01                        Page 28 of 28



Document Created: 2019-03-19 08:22:29
Document Modified: 2019-03-19 08:22:29

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC