MDE_UBLOX_1807_FCCd-FINAL-2019-02-21

FCC ID: XPYTOBYL201

Test Report

Download: PDF
FCCID_4217994

FCC Measurement/Technical Report on



TOBY-L201 LTE/3G data only module

FCC ID: XPYTOBYL201
IC: 8595A-TOBYL201
acc. to FCC Part 15 Subpart B


Test Report Reference: MDE_UBLOX_1807_FCCd




Test Laboratory:
7layers GmbH
Borsigstrasse 11
40880 Ratingen
Germany

Note:
The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts
without the written approval of the test laboratory.

7layers GmbH                       Geschäftsführer/
Borsigstraße 11                    Managing Directors:                Registergericht/registered:                           a Bureau Veritas
40880 Ratingen, Germany            Frank Spiller                      Düsseldorf HRB 75554                                  Group Company
T +49 (0) 2102 749 0               Bernhard Retka                     USt-Id.-Nr./VAT-No. DE203159652
F +49 (0) 2102 749 350             Alexandre Norré-Oudard             Steuer-Nr./TAX-No. 147/5869/0385                      www.7layers.com


Commerzbank AG     Account No. 303 016 000 Bank Code 300 400 00    IBAN DE81 3004 0000 0303 0160 00 Swift Code COBADEFF


Table of Contents

1 Applied Standards and Test Summary                        3
1.1   Applied Standards                                      3
1.2   FCC-IC Correlation Table                               4
1.3   Measurement Summary / Signatures                       4

2 Administrative Data                                       6
2.1   Testing Laboratory                                     6
2.2   Project Data                                           6
2.3   Applicant Data                                         6
2.4   Manufacturer Data                                      6

3 Test object Data                                          7
3.1   General EUT Description                                7
3.2   EUT Main components                                    7
3.3   Ancillary Equipment                                    8
3.4   Auxiliary Equipment                                    8
3.5   EUT Setups                                             8
3.6   Operating Modes                                        9
3.7   Product labelling                                      9

4 Test Results                                            10
4.1   Conducted Emissions at AC mains                      10
4.2   Radiated Emissions                                   13

5 Test Equipment                                          18

6 Antenna Factors, Cable Loss and Sample Calculations     21
6.1   LISN R&S ESH3-Z5 (150 kHz – 30 MHz)                  21
6.2   Antenna R&S HFH2-Z2 (9 kHz – 30 MHz)                 22
6.3   Antenna R&S HL562 (30 MHz – 1 GHz)                   23
6.4   Antenna R&S HF907 (1 GHz – 18 GHz)                   24
6.5   Antenna EMCO 3160-09 (18 GHz – 26.5 GHz)             25
6.6   Antenna EMCO 3160-10 (26.5 GHz – 40 GHz)             26

7 Setup Drawings                                          27

8 Measurement Uncertainties                               28

9 Photo Report                                            28




TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd              Page 2 of 28


1 APPLIED STANDARDS AND TEST SUMMARY

1.1   APPLIED STANDARDS


Applicable FCC Rules

Prepared in accordance with the requirements of FCC Rules and Regulations as listed in 47 CFR
Ch.1 Parts 2 and 15 (10-1-15 Edition). The following subparts are applicable to the results in
this test report.


Part 2, Subpart J - Equipment Authorization Procedures, Certification

Part 15, Subpart B – Unintentional Radiators

§ 15.107   Conducted limits

§ 15.109   Radiated emission limits; general requirements


Note:
ANSI C63.4–2014 is applied.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                        Page 3 of 28


Summary Test Results:

The EUT complied with all performed tests as listed in chapter 1.3 Measurement
Summary / Signatures.


1.2   FCC-IC CORRELATION TABLE


                 Correlation of measurement requirements for
                   Information Technology Equipment (ITE)
                                     from
                                  FCC and IC

 Measurement                   FCC reference               IC reference
 Conducted Emissions           §15.107                     ICES-003 Issue 6: 6.1
 (AC Power Line)
 Radiated Spurious Emissions   §15.109                     ICES-003 Issue 6: 6.2


Remarks:

1. FCC Part 15 subpart B, ICES 003 and CISPR 22 contain different definitions of Class A and
   Class B limits, i.e. which class is applicable to which kind of EUT.
   ICES 003 and CISPR 22 distinguish between the location where the EUT is intended to
   operate whilst FCC refers to the method of commercial distribution (distributive trades).
2. The correct assignment of the appropriate class to the concrete EUT is not scope of this
   test report!
3. A radio apparatus that is specifically subject to an Industry Canada Radio Standard
   Specification (RSS) and which contains an ITE is not subject to ICES-003 provided the ITE
   is used only to enable operation of the radio apparatus and the ITE does not control
   additional functions or capabilities.
4. ISM (Industrial, Scientific or Medical) radio frequency generators, though they may contain
   ITE, are excluded from the definition of ITE and are not subject to ICES-003. They are
   instead subject to the Interference-Causing Equipment Standard ICES-001, which
   specifically addresses ISM radio frequency generators.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                        Page 4 of 28


                                                                                 7Zlayers




                                                                                   <
                                                                                          A Bureau Veritas Group Company




                                                                                   N
                                                                              WtU
1.3   MEASUREMENT SUMMARY / SIGNATURES


47 CFR CHAPTER I FCC PART 15 Subpart B                              § 15.107 Class B
Conducted Emissions at AC mains
The measurement was performed according to ANSI C63.4                                   Final Result

OP—Mode                                                                Setup            FCC              IC
AC mains connection, Test setup
via auxiliary equipment, computer peripheric                           S01_ABO2          Passed          Passed


47 CFR CHAPTER I FCC PART 15 Subpart B                              § 15.109 Class B
 Radiated Emissions
The measurement was performed according to ANSI C63.4                                    Final Result

OP—Mode                                                                Setup             FCC             IC
AC mains connection, Measurement range, Test setup
via auxiliary equipment, 1 GHz — 18 GHz, computer peripheric           S01_ABO2          Passed          Passed
via auxiliary equipment, 30 MHz — 1 GHz, computer peripheric           S01_ABO2          Passed          Passed



N/A: Not applicable
N/P: Not performed




       L. |wL
      " (responsible for accreditation scope)
                                                                    Tbiout
                                                               K res;fio?fsible for testing and report)
            Dipl.—Ing. Marco Kullik                                    B.Sc. Jens Dorwald

                                                                V




                                                       Sorsigstr. 11
                                      7 layers GmoH.
                                      40880 Rati ng en , Germany
                                       Phone +49 (0)2102 749      0




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                                              Page 5 of 28


2 ADMINISTRATIVE DATA

2.1   TESTING LABORATORY

Company Name:                            7layers GmbH

Address:                                 Borsigstr. 11
                                         40880 Ratingen
                                         Germany

This facility has been fully described in a report submitted to the ISED and accepted under
the registration number: Site# 3699A-1.

The test facility is also accredited by the following accreditation organisation:

Laboratory accreditation no:             DAkkS D-PL-12140-01-00

FCC Designation Number:                  DE0015

FCC Test Firm Registration:              929146

Responsible for accreditation scope:     Dipl.-Ing. Marco Kullik

Report Template Version:                 2018-01-10


2.2   PROJECT DATA

Responsible for testing and report:      B.Sc. Jens Dörwald

Employees who performed the tests:       documented internally at 7Layers

Date of Report:                          2019-02-21

Testing Period:                          2018-12-21 to 2018-12-21



2.3   APPLICANT DATA

Company Name:                            u-blox AG

Address:                                 Zürcherstrasse 68
                                         CH-8800 Thalwil
                                         Switzerland

Contact Person:                          Mr. Giulio Comar


2.4   MANUFACTURER DATA

Company Name:                            please see Applicant Data

Address:
Contact Person:

 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                         Page 6 of 28


3 TEST OBJECT DATA

3.1     GENERAL EUT DESCRIPTION

Kind of Device                   LTE Module
product description
Product name                     TOBY-L201 LTE/3G data only module
Type                             -

Declared EUT data by the supplier

Power Supply Type                DC
Nominal Voltage /                INPUT: 120 V / 60 Hz
Frequency                        OUTPUT: 3.8 V DC
Test Voltage /                   INPUT: 120 V / 60 Hz
Frequency                        OUTPUT: 3.8 V DC
Highest internal                 2600 MHz
frequency
General Description              The EUT is a LTE Module.
Ports                            DC
                                 USB
                                 Antenna
Special software used            -
for testing

The main components of the EUT are listed and described in chapter 3.2 EUT Main
components.


3.2     EUT MAIN COMPONENTS

Sample Name                       Sample Code                                  Description
ab02                              ab02                                         Standard Sample
   Sample Parameter                                                       Value
Serial No.                        358502064213351
HW Version                        218B01
SW Version                        v20.00
Comment                           -

NOTE:The short description is used to simplify the identification of the EUT in this test report.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                                         Page 7 of 28


3.3      ANCILLARY EQUIPMENT

For the purposes of this test report, ancillary equipment is defined as equipment which is used
in conjunction with the EUT to provide operational and control features to the EUT. It is
necessary to configure the system in a typical fashion, as a customer would normally use it.
But nevertheless Ancillary Equipment can influence the test results.

Device                       Details                                   Description
                             (Manufacturer, Type Model, OUT
                             Code)
-                            -                                         -


3.4      AUXILIARY EQUIPMENT

For the purposes of this test report, auxiliary equipment is defined as equipment which is used
temporarily to enable operational and control features especially used for the tests of the EUT
which is not used during normal operation or equipment that is used during the tests in
combination with the EUT but is not subject of this test report. It is necessary to configure the
system in a typical fashion, as a customer would normally use it.
But nevertheless Auxiliary Equipment can influence the test results.

Device                        Details                                   Description
                              (Manufacturer, HW, SW, S/N)
AUX1: AC/DC Adapter          UNIFIVE UUX324-1215, -, -, J04-           power supply for EUT
                             0543732
AUX2: LTE Antenna 1          Taoglas, -, -, -                          -

AUX3: LTE Antenna 2          Taoglas, -, -, -                          -

AUX4: Evaluation board       Ublox EVB-WL3, - , - , -                  -

AUX5: Monitor                LG L17MB-P, -, -, 412 WAPL0U560           -

AUX6: Laptop                 FUJITSU Ltd LIFEBOOK U758, 2018-07,       -
                             Win10 Pro, DSAL009842
AUX7: AC/ DC Adapter         FUJITSU Ltd. A13-065N3A, -, -,            power supply for Laptop
                             186905OL04
AUX8: Keyboard               CHERRY RS6000 USB ON, -, -, G             -
                             0000273 2P28


3.5      EUT SETUPS

This chapter describes the combination of EUTs and equipment used for testing. The rationale
for selecting the EUTs, ancillary and auxiliary equipment and interconnecting cables, is to test
a representative configuration meeting the requirements of the referenced standards.

      Setup               Combination of EUTs                  Description and Rationale
    S01_AB02               ab02 + AUX1 – AUX8                computer peripheral setup




    TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                             Page 8 of 28


3.6   OPERATING MODES
This chapter describes the operating modes of the EUTs used for testing.

LTE eFDD17 idle mode & USB traffic

3.6.1 TEST CHANNELS
---




3.7   PRODUCT LABELLING

3.7.1 FCC ID LABEL
Please refer to the documentation of the applicant.


3.7.2 LOCATION OF THE LABEL ON THE EUT
Please refer to the documentation of the applicant.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                Page 9 of 28


4 TEST RESULTS



4.1   CONDUCTED EMISSIONS AT AC MAINS

Standard      FCC Part 15 Subpart B

The test was performed according to:
ANSI C63.4

4.1.1 TEST DESCRIPTION

The test set-up was made in accordance to the general provisions of ANSI C 63.4
The Equipment Under Test (EUT) was setup in a shielded room to perform the conducted
emissions measurements in a typical installation configuration. The EUT was powered from
50µH || 50 Ohm Line Impedance Stabilization Network (LISN). The LISN’s unused connections
were terminated with 50 Ohm loads.

The measurement procedure consists of two steps. It is implemented into the EMI test
software EMC-32 from R&S.

Step 1: Preliminary scan
Intention of this step is, to determine the conducted EMI-profile of the EUT.
EMI receiver settings:
- Detector: Peak – Maxhold & Average
- Frequency range: 150 kHz – 30 MHz
- Frequency steps: 2.5 kHz
- IF–Bandwidth: 9 kHz
- Measuring time / Frequency step: 100 ms (FFT-based)
- Measurement on phase + neutral lines of the power cords

On basis of this preliminary scan the highest amplitudes and the corresponding frequencies
relative to the limit are identified. Emissions above the limit and emissions which are in the 10
dB range below the limit are considered.

Step 2: Final measurement
Intention of this step is, to determine the highest emissions with the settings defined in the
test specification for the frequencies identified in step 1.
EMI receiver settings:
- Detector: Quasi-Peak
- IF Bandwidth: 9 kHz
- Measuring time: 1 s / frequency

At each frequency determined in step 1, four measurements are performed in the following
combinations:
1) Neutral lead - reference ground (PE grounded)
2) Phase lead - reference ground (PE grounded)
3) Neutral lead - reference ground (PE floating)
4) Phase lead - reference ground (PE floating)

The highest value is reported.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                          Page 10 of 28


4.1.2 TEST REQUIREMENTS / LIMITS

FCC Part 15, Subpart B, §15.107

Class B:
 Frequency (MHz)       QP Limits (dBµV)      AV Limits (dBµV)
 0.15 – 0.5            66 - 56               56 - 46
 0.5 - 5               56                    46
 5 - 30                60                    50


Class A:
 Frequency (MHz)       QP Limits (dBµV)      AV Limits (dBµV)
 0.15 – 0.5            79                    66
 0.5 - 30              73                    60




4.1.3 TEST PROTOCOL

 Temperature:           23 °C
 Air Pressure:          996 hPa
 Humidity:              37 %
 Computer Peripheral
 Power line    PE       Frequency [MHz]     Level [dBµV]       Detector   Limit [dBµV]   Margin [dB]
 L1            FLO      0.42                41.8               QP         57.4           15.6
 L1            GND      0.44                36.2               AV         47.1           10.8


Remark: Please see next sub-clause for the measurement plot.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                                       Page 11 of 28


4.1.4 MEASUREMENT PLOT (SHOWING THE HIGHEST VALUE, “WORST CASE”)
                                                                     150 kHz -30 MHz


                             80



                             70


                                                                                                            L imit_ 1 5 _ 1 0 7 _ Q P _ Cla s sB
                             60


                                                                                                            L imit_ 1 5 _ 1 0 7 _ A V _ Cla ss B
                             50
             Level in dBµV




                             40



                             30



                             20



                             10



                             0
                             150k            3 0 0 4 0 05 0 0    8 0 01 M         2M       3M 4M 5M 6        8 10M             20M 30M
                                                                             F re q u e n c y in H z


 Frequency                    QuasiPeak          CAverage          Limit      Margin        Meas. Time      Bandwidth       Line      PE       Corr.
   (MHz)                       (dBµV)             (dBµV)          (dBµV)       (dB)           (ms)            (kHz)                            (dB)

      0.424500                      41.81                  ---       57.36       15.55             1000.0         9.000   L1        FLO            10.1
      0.440250                         ---              36.23        47.06       10.83             1000.0         9.000   L1        GND            10.1




4.1.5 TEST EQUIPMENT USED
  -     Conducted Emissions FCC




TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                                                                           Page 12 of 28


4.2   RADIATED EMISSIONS

Standard      FCC Part 15 Subpart B

The test was performed according to:
ANSI C63.4

4.2.1 TEST DESCRIPTION

The test set-up was made in accordance to the general provisions of ANSI C63.4 in a typical
installation configuration. The Equipment Under Test (EUT) was set up on a non-conductive
table 1.0 x 2.0 m² in the semi-anechoic chamber. The influence of the EUT support table that
is used was evaluated. For the measurement above 1 GHz an absorber field with 30 cm
pyramidical absorber is placed between EUT table and antenna (required to fulfil the CISPR
16.1.4 S-VSWR criteria).
The measurement procedure is implemented into the EMI test software EMC32 from R&S.

1. Measurement above 30 MHz and up to 1 GHz

Step 1: Preliminary scan
This is a preliminary test to identify the highest amplitudes relative to the limit.
Settings for step 1:
- Antenna distance: 3 m
- Detector: Peak-Maxhold / Quasipeak (FFT-based)
- Frequency range: 30 – 1000 MHz
- Frequency steps: 30 kHz
- IF–Bandwidth: 120 kHz
- Measuring time / Frequency step: 100 ms
- Turntable angle range: –180° to 90°
- Turntable step size: 90°
- Height variation range: 1 – 3 m
- Height variation step size: 2 m
- Polarisation: Horizontal + Vertical
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.

Step 2: Adjustment measurement
In this step the accuracy of the turntable azimuth and antenna height will be improved. This is
necessary to find out the maximum value of every frequency.
For each frequency, which was determined the turntable azimuth and antenna height will be
adjusted. The turntable azimuth will slowly vary by ± 45° around this value. During this action,
the value of emission is continuously measured. The turntable azimuth at the highest emission
will be recorded and adjusted. In this position, the antenna height will also slowly vary by ±
100 cm around the antenna height determined. During this action, the value of emission is
also continuously measured. The antenna height of the highest emission will also be recorded
and adjusted.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: ± 45 ° around the determined value
- Height variation range: ± 100 cm around the determined value

 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                          Page 13 of 28


- Antenna Polarisation: max. value determined in step 1

Step 3: Final measurement with QP detector
With the settings determined in step 3, the final measurement will be performed:
EMI receiver settings for step 4:
- Detector: Quasi-Peak
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 1 s

2. Measurement above 1 GHz

Step 1: Preliminary scan
This is a preliminary test to identify the highest amplitudes relative to the limit.
Settings for step 1:
- Antenna distance: 3 m
- Detector: Peak-Maxhold / Average (up to 7 GHz FFT-based)
- Frequency range: 1 GHz – 18 GHz
- Frequency steps: 250 kHz
- IF–Bandwidth: 1 MHz
- Measuring time / Frequency step: 100 ms (up to 7 GHz) / 500µs (above 7 GHz
- Turntable angle range: –180° to 135°
- Turntable step size: 45°
- Height variation range: 1 – 3.7 m (due to the small antenna lobe, a tilt-mast is used)
- Height variation step size: 0.9 m
- Polarisation: Horizontal + Vertical
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.

Step 2: Adjustment measurement
In this step the accuracy of the turntable azimuth and antenna height will be improved. This is
necessary to find out the maximum value of every frequency.
For each frequency, which was determined the turntable azimuth and antenna height will be
adjusted. The turntable azimuth will slowly vary by ± 22.5° around this value. During this
action, the value of emission is continuously measured. The turntable azimuth at the highest
emission will be recorded and adjusted. In this position, the antenna height will also slowly
vary by ± 45 cm around the antenna height determined. During this action, the value of
emission is also continuously measured. The antenna height of the highest emission will also
be recorded and adjusted.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 1 MHz
- Measuring time: 100 ms
- Turntable angle range: ± 22.5 ° around the determined value
- Height variation range: ± 45 cm around the determined value
- Antenna Polarisation: max. value determined in step 1

Step 3: Final measurement with Max-Peak / CISPR-Average detector
With the settings determined in step 2, the final measurement will be performed:
EMI receiver settings for step 3:
- Detector: Max-Peak / CISPR-Average
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 1 MHz
- Measuring time: 200 ms



 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                          Page 14 of 28


After each measurement, a report will be generated which contains a diagram with the results
of the preliminary scan and a table with the frequencies, values and polarisation of the results
of the final measurement.



4.2.2 TEST REQUIREMENTS / LIMITS

FCC Part 15, Subpart B, §15.109, Radiated Emission Limits

Class B:
                                             Measurement
 Frequency (MHz)     Limit (µV/m)                               Limits (dBµV/m)
                                             distance (m)
 30 – 88             100@3m                  3                  40.0@3m
 88 – 216            150@3m                  3                  43.5@3m
 216 – 960           200@3m                  3                  46.0@3m
 960 - 26000         500@3m                  3                  54.0@3m
 26000 - 40000       500@3m                  1                  54.0@3m


Class A:
                                             Measurement
 Frequency (MHz)     Limit (µV/m)                               Limits (dBµV/m)
                                             distance (m)
 30 – 88             90@10m                  3                  39.1@10m
 88 – 216            150@10m                 3                  43.5@10m
 216 – 960           210@10m                 3                  46.4@10m
 960 - 26000         300@10m                 3                  49.5@10m
 26000 - 40000       300@10m                 1                  49.5@10m




The measured values for Class A and for Class B (> 26 GHz) measurements are corrected with
an inverse linear distance extrapolation factor (20 dB/decade).

§15.35(b) ..., there is also a limit on the radio frequency emissions, as measured using
instrumentation with a peak detector function, corresponding to 20 dB above the maximum
permitted average limit....

Used conversion factor: Limit (dBµV/m) = 20 log (Limit (µV/m)/1µV/m)



4.2.3 TEST PROTOCOL

 Ambient temperature:     23 °C
 Air Pressure:            996 hPa
 Humidity:                37 %
 Computer Peripheral
 Setup
 Spurious Freq.           Spurious Level           Detector    RBW         Limit      Margin to Limit
 [MHz]                    [dBµV/m]                             [kHz]       [dBµV/m]   [dB]
 32.9                     39.4                     QP          120         40.0       0.6
 40.1                     35.7                     QP          120         40.0       4.3
 75.6                     34.4                     QP          120         40.0       5.6
 209.1                    16.6                     QP          120         43.5       26.9
 216.0                    19.2                     QP          120         43.5       24.3
 599.9                    27.3                     QP          120         46.0       18.7
 5993.3                   28.26                    AV          1000        54.0       25.7
 5999.0                   54.47                    PK          1000        74.0       19.5

Remark: Please see next sub-clause for the measurement plot.

 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                               Page 15 of 28


4.2.4 MEASUREMENT PLOT (SHOWING THE HIGHEST VALUE, “WORST CASE”)
                                                                 30 MHz – 1 GHz


                               60

                               55                                                         F CC _ 1 5 .1 0 9 _ Cla ss B @ 3 m _ 3 0 M H z -1 G H z

                               50

                               45

                               40

                               35
             Level in dBµV/m




                               30

                               25

                               20

                               15

                               10

                               5

                               0

                               -5


                               30M            50 60        80 100M                 200          300    400 500             800 1G
                                                                      F re q u e n c y in H z


 Frequency                      QuasiPeak       Limit       Margin    Meas. Time         Bandwidth      Height     Pol     Azimuth        Corr.
   (MHz)                        (dBµV/m)      (dBµV/m)       (dB)       (ms)               (kHz)         (cm)               (deg)        (dB/m)

   32.910000                          39.43        40.00       0.57         1000.0           120.000      100.0   V            -173.0       17.7
   40.080000                          35.73        40.00       4.27         1000.0           120.000      103.0   V            -188.0       13.6
   75.600000                          34.38        40.00       5.62         1000.0           120.000      118.0   V             129.0        9.6
  209.130000                          16.58        43.50      26.92         1000.0           120.000      195.0   V            -190.0        9.8
  215.970000                          19.22        43.50      24.28         1000.0           120.000      105.0   V            -165.0       10.2
  599.880000                          27.34        46.00      18.66         1000.0           120.000      200.0   H            -194.0       20.4




TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                                                                      Page 16 of 28


                                                                     1 GHz – 18 GHz


                                 80
                                                                                        F CC _ 1 5 .1 0 9 _ Cla ss B @ 3 m _ 1 G H z -1 8 G H z _ P e a k

                                 70



                                 60
                                                                                           F CC _ 1 5 .1 0 9 _ Cla ss B @ 3 m _ 1 G H z -1 8 G H z _ A V

                                 50
               Level in dBµV/m




                                 40



                                 30



                                 20



                                 10



                                 0
                                  1G                      2G          3G         4G       5G     6         8        10G                  18G
                                                                             F re q u e n c y in H z


 Frequency                 MaxPeak         CAverage       Limit    Margin      Meas.       Bandwidth      Height         Pol   Azimuth          Corr.
   (MHz)                   (dBµV/m)        (dBµV/m)     (dBµV/m)    (dB)       Time          (kHz)         (cm)                 (deg)          (dB/m)
                                                                               (ms)
 5993.250000                         ---       28.26       54.00     25.74      200.0          1000.000     172.0    V            32.0                  14.6
 5999.000000                      54.47           ---      74.00     19.53      200.0          1000.000     172.0    V            32.0                  14.5




4.2.5 TEST EQUIPMENT USED
    -    Radiated Emissions




TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                                                                               Page 17 of 28


5 TEST EQUIPMENT
1       Conducted Emissions FCC
        Conducted Emissions power line for FCC standards

Ref.No. Device Name Description        Manufacturer        Serial Number       Last    Calibration
                                                                           Calibration     Due
1.1     Opus10 TPR      ThermoAirpres Lufft Mess- und      13936           2017-04     2019-04
        (8253.00)       sure           Regeltechnik GmbH
                        Datalogger 13
                        (Environ)
1.2     Fluke 177       Digital        Fluke Europe B.V.   86670383        2018-04     2020-04
                        Multimeter 03
                        (Multimeter)
1.3     ESH3-Z5         Two-Line V-    Rohde & Schwarz     828304/029      2017-05     2019-05
                        Network
1.4     EP 1200/B,      Amplifier with Spitzenberger &     B6278
        NA/B1           integrated     Spieß
                        variable
                        Oscillator
1.5     Chroma 6404     AC Power       Chroma ATE INC.     64040001304
                        Source
1.6     Shielded Room   Shielded Room Frankonia            -
        02              for conducted
                        testing, 12qm
1.7     ESH3-Z5         Two-Line V-    Rohde & Schwarz     829996/002      2017-05     2019-05
                        Network
1.8     ESR 7           EMI Receiver / Rohde & Schwarz     101424
                        Spectrum
                        Analyzer
1.9     Opus10 THI      ThermoHygro Lufft Mess- und        7489            2017-04     2019-04
        (8152.00)       Datalogger 02 Regeltechnik GmbH
                        (Environ)
1.10    ESIB 26         Spectrum       Rohde & Schwarz     830482/004      2018-01     2020-01
                        Analyzer

2       Radiated Emissions
        Lab to perform radiated emission tests

Ref.No. Device Name Description        Manufacturer        Serial Number       Last    Calibration
                                                                           Calibration     Due
2.1     NRV-Z1          Sensor Head A Rohde & Schwarz      827753/005      2018-07     2019-07
                                       GmbH & Co. KG
2.2     MFS             Rubidium       Datum GmbH          002             2018-10     2020-10
                        Frequency
                        Normal MFS
2.3     Opus10 TPR      ThermoAirpres Lufft Mess- und      13936           2017-04     2019-04
        (8253.00)       sure           Regeltechnik GmbH
                        Datalogger 13
                        (Environ)
2.4     ESW44           EMI Test       Rohde & Schwarz     101603          2018-05     2019-05
                        Receiver       GmbH & Co. KG
2.5     Anechoic        10.58 x 6.38 x Frankonia           none            2018-06     2020-06
        Chamber         6.00 m³
2.6     FS-Z60          Harmonic       Rohde & Schwarz     100178          2016-12     2019-12
                        Mixer 40 - 60 Messgerätebau
                        GHz            GmbH
2.7     FS-Z220         Harmonic       Rohde & Schwarz     101005          2017-03     2020-03
                        Mixer 140 -    Messgerätebau
                        220 GHz        GmbH

 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                          Page 18 of 28


Ref.No. Device Name Description           Manufacturer       Serial Number       Last    Calibration
                                                                             Calibration     Due
2.8     SGH-05         Standard Gain    RPG-Radiometer       075
                       / Pyramidal      Physics GmbH
                       Horn Antenna
                       (140 - 220
                       GHz)
2.9     HL 562         Ultralog new     Rohde & Schwarz      830547/003      2018-07     2021-07
                       biconicals
2.10    5HC2700/12750 High Pass         Trilithic            9942012
        -1.5-KK        Filter
2.11    ASP 1.2/1.8-10 Antenna Mast     Maturo GmbH          -
        kg
2.12    Fully Anechoic 8.80m x          Albatross Projects   P26971-647-001- 2018-06     2020-06
        Room           4.60m x                               PRB
                       4.05m (l x w x
                       h)
2.13    Fluke 177      Digital          Fluke Europe B.V.    86670383        2018-04     2020-04
                       Multimeter 03
                       (Multimeter)
2.14    NRVD           Power Meter      Rohde & Schwarz      828110/016      2018-07     2019-07
                                        GmbH & Co. KG
2.15    HF 906            Double-ridged Rohde & Schwarz      357357/002      2018-09     2021-09
                          horn
2.16    JS4-18002600-     Broadband     Miteq                849785
        32-5P             Amplifier 18
                          GHz - 26 GHz
2.17    FSW 43            Spectrum      Rohde & Schwarz      103779
                          Analyzer
2.18    3160-09           Standard Gain EMCO Elektronic      00083069
                          / Pyramidal   GmbH
                          Horn Antenna
                          26.5 GHz
2.19    SGH-19            Standard Gain RPG-Radiometer       093
                          / Pyramidal   Physics GmbH
                          Horn Antenna
                          (40 - 60 GHz)
2.20    WHKX 7.0/18G-     High Pass     Wainwright           09
        8SS               Filter
2.21    4HC1600/12750     High Pass     Trilithic            9942011
        -1.5-KK           Filter
2.22    Chroma 6404       AC Power      Chroma ATE INC.      64040001304
                          Source
2.23    JS4-00102600-     Broadband     Miteq                619368
        42-5A             Amplifier 30
                          MHz - 26 GHz
2.24    TT 1.5 WI         Turn Table    Maturo GmbH          -
2.25    HL 562 Ultralog   Log.-per.     Rohde & Schwarz      100609          2016-04     2019-04
                          Antenna
2.26    HF 906            Double-ridged Rohde & Schwarz      357357/001      2018-03     2021-03
                          horn
2.27    FS-Z325           Harmonic      Rohde & Schwarz      101006          2017-03     2020-03
                          Mixer 220 -   Messgerätebau
                          325 GHz       GmbH
2.28    3160-10           Standard Gain EMCO Elektronic      00086675
                          / Pyramidal   GmbH
                          Horn Antenna
                          40 GHz




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                            Page 19 of 28


Ref.No. Device Name Description         Manufacturer      Serial Number        Last    Calibration
                                                                           Calibration     Due
2.29    SGH-08          Standard Gain RPG-Radiometer      064
                        / Pyramidal    Physics GmbH
                        Horn Antenna
                        (90 - 140
                        GHz)
2.30    SGH-12          Standard Gain RPG-Radiometer      326
                        / Pyramidal    Physics GmbH
                        HornAntenna
                        (60 - 90 GHz)
2.31    5HC3500/18000 High Pass        Trilithic          200035008
        -1.2-KK         Filter
2.32    FS-Z140         Harmonic       Rohde & Schwarz    101007           2017-02     2020-02
                        Mixer 90 -140 Messgerätebau
                        GHz            GmbH
2.33    HFH2-Z2         Loop Antenna Rohde & Schwarz      829324/006       2018-01     2021-01
2.34    Opus10 THI      ThermoHygro Lufft Mess- und       12482            2017-03     2019-03
        (8152.00)       Datalogger 12 Regeltechnik GmbH
                        (Environ)
2.35    ESR 7           EMI Receiver / Rohde & Schwarz    101424
                        Spectrum
                        Analyzer
2.36    JS4-00101800- Broadband        Miteq              896037
        35-5P           Amplifier 30
                        MHz - 18 GHz
2.37    AS 620 P        Antenna mast HD GmbH              620/37
2.38    Tilt device     Antrieb TD1.5- Maturo GmbH        TD1.5-
        Maturo          10kg                              10kg/024/37907
        (Rohacell)                                        09
2.39    SGH-03          Standard Gain RPG-Radiometer      060
                        / Pyramidal    Physics GmbH
                        Horn Antenna
                        (220 - 325
                        GHz)
2.40    FS-Z90          Harmonic       Rohde & Schwarz    101686           2017-03     2020-03
                        Mixer 60 - 90 Messgerätebau
                        GHz            GmbH
2.41    ESIB 26         Spectrum       Rohde & Schwarz    830482/004       2018-01     2020-01
                        Analyzer
2.42    PAS 2.5 - 10 kg Antenna Mast Maturo GmbH          -
2.43    AFS42-          Broadband      Miteq              2035324
        00101800-25-S- Amplifier 25
        42              MHz - 18 GHz
2.44    AM 4.0          Antenna mast Maturo GmbH          AM4.0/180/1192
                                                          0513
2.45    HF 907          Double-ridged Rohde & Schwarz     102444         2018-07       2021-07
                        horn


The calibration interval is the time interval between “Last Calibration” and “Calibration Due”




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                          Page 20 of 28


6 ANTENNA FACTORS, CABLE LOSS AND SAMPLE CALCULATIONS
This chapter contains the antenna factors with their corresponding path loss of the used
measurement path for all antennas as well as the insertion loss of the LISN.



6.1    LISN R&S ESH3-Z5 (150 KHZ – 30 MHZ)
                                                         cable
                                              LISN        loss
                                           insertion   (incl. 10
                                              loss         dB
                                             ESH3-      atten-
  Frequency                 Corr.              Z5       uator)
     MHz                     dB                dB          dB
       0.15                   10.1               0.1        10.0
          5                   10.3               0.1        10.2
          7                   10.5               0.2        10.3
         10                   10.5               0.2        10.3
         12                   10.7               0.3        10.4
         14                   10.7               0.3        10.4
         16                   10.8               0.4        10.4
         18                   10.9               0.4        10.5
         20                   10.9               0.4        10.5
         22                   11.1               0.5        10.6
         24                   11.1               0.5        10.6
         26                   11.2               0.5        10.7
         28                   11.2               0.5        10.7
         30                   11.3               0.5        10.8

Sample calculation

  ULISN (dB µV) = U (dB µV) + Corr. (dB)
  U = Receiver reading
  LISN Insertion loss = Voltage Division Factor of LISN
  Corr. = sum of single correction factors of used LISN, cables, switch units (if used)
  Linear interpolation will be used for frequencies in between the values in the table.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                               Page 21 of 28


6.2    ANTENNA R&S HFH2-Z2 (9 KHZ – 30 MHZ)
                                              cable        cable        cable        cable     distance     dLimit      dused
                                              loss 1       loss 2      loss 3       loss 4       corr.     (meas.      (meas.
                  AF                         (inside      (outside    (switch         (to      (-40 dB/   distance    distance
  Frequency    HFH-Z2)       Corr.          chamber)     chamber)       unit)     receiver)    decade)     (limit)     (used)
     MHz       dB (1/m)       dB                dB           dB          dB           dB          dB          m          m
      0.009      20.50        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.01      20.45        -79.6                0.1          0.1         0.1          0.1        -80        300            3
      0.015      20.37        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.02      20.36        -79.6                0.1          0.1         0.1          0.1        -80        300            3
      0.025      20.38        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.03      20.32        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.05      20.35        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.08      20.30        -79.6                0.1          0.1         0.1          0.1        -80        300            3
        0.1      20.20        -79.6                0.1          0.1         0.1          0.1        -80        300            3
        0.2      20.17        -79.6                0.1          0.1         0.1          0.1        -80        300            3
        0.3      20.14        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.49      20.12        -79.6                0.1          0.1         0.1          0.1        -80        300            3
   0.490001      20.12        -39.6                0.1          0.1         0.1          0.1        -40          30           3
        0.5      20.11        -39.6                0.1          0.1         0.1          0.1        -40          30           3
        0.8      20.10        -39.6                0.1          0.1         0.1          0.1        -40          30           3
          1      20.09        -39.6                0.1          0.1         0.1          0.1        -40          30           3
          2      20.08        -39.6                0.1          0.1         0.1          0.1        -40          30           3
          3      20.06        -39.6                0.1          0.1         0.1          0.1        -40          30           3
          4      20.05        -39.5                0.2          0.1         0.1          0.1        -40          30           3
          5      20.05        -39.5                0.2          0.1         0.1          0.1        -40          30           3
          6      20.02        -39.5                0.2          0.1         0.1          0.1        -40          30           3
          8      19.95        -39.5                0.2          0.1         0.1          0.1        -40          30           3
         10      19.83        -39.4                0.2          0.1         0.2          0.1        -40          30           3
         12      19.71        -39.4                0.2          0.1         0.2          0.1        -40          30           3
         14      19.54        -39.4                0.2          0.1         0.2          0.1        -40          30           3
         16      19.53        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         18      19.50        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         20      19.57        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         22      19.61        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         24      19.61        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         26      19.54        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         28      19.46        -39.2                0.3          0.1         0.3          0.1        -40          30           3
         30      19.73        -39.1                0.4          0.1         0.3          0.1        -40          30           3

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  distance correction = -40 * LOG (dLimit/ dused)
  Linear interpolation will be used for frequencies in between the values in the table.
  Table shows an extract of values




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                                                 Page 22 of 28


6.3    ANTENNA R&S HL562 (30 MHZ – 1 GHZ)
(dLimit = 3 m)
                                              cable       cable         cable       cable     distance     dLimit       dused
                    AF                        loss 1      loss 2       loss 3      loss 4       corr.     (meas.       (meas.
                   R&S                       (inside     (outside     (switch        (to      (-20 dB/   distance     distance
  Frequency       HL562      Corr.          chamber)    chamber)        unit)    receiver)    decade)     (limit)      (used)
     MHz         dB (1/m)     dB                dB          dB           dB          dB          dB          m           m
         30          18.6       0.6              0.29        0.04         0.23         0.02        0.0            3           3
         50           6.0       0.9              0.39        0.09         0.32         0.08        0.0            3           3
        100           9.7       1.2              0.56        0.14         0.47         0.08        0.0            3           3
        150           7.9       1.6              0.73        0.20         0.59         0.12        0.0            3           3
        200           7.6       1.9              0.84        0.21         0.70         0.11        0.0            3           3
        250           9.5       2.1              0.98        0.24         0.80         0.13        0.0            3           3
        300          11.0       2.3              1.04        0.26         0.89         0.15        0.0            3           3
        350          12.4       2.6              1.18        0.31         0.96         0.13        0.0            3           3
        400          13.6       2.9              1.28        0.35         1.03         0.19        0.0            3           3
        450          14.7       3.1              1.39        0.38         1.11         0.22        0.0            3           3
        500          15.6       3.2              1.44        0.39         1.20         0.19        0.0            3           3
        550          16.3       3.5              1.55        0.46         1.24         0.23        0.0            3           3
        600          17.2       3.5              1.59        0.43         1.29         0.23        0.0            3           3
        650          18.1       3.6              1.67        0.34         1.35         0.22        0.0            3           3
        700          18.5       3.6              1.67        0.42         1.41         0.15        0.0            3           3
        750          19.1       4.1              1.87        0.54         1.46         0.25        0.0            3           3
        800          19.6       4.1              1.90        0.46         1.51         0.25        0.0            3           3
        850          20.1       4.4              1.99        0.60         1.56         0.27        0.0            3           3
        900          20.8       4.7              2.14        0.60         1.63         0.29        0.0            3           3
        950          21.1       4.8              2.22        0.60         1.66         0.33        0.0            3           3
       1000          21.6       4.9              2.23        0.61         1.71         0.30        0.0            3           3


(dLimit = 10 m)
           30       18.6        -9.9             0.29         0.04        0.23        0.02       -10.5          10           3
           50        6.0        -9.6             0.39         0.09        0.32        0.08       -10.5          10           3
          100        9.7        -9.2             0.56         0.14        0.47        0.08       -10.5          10           3
          150        7.9        -8.8             0.73         0.20        0.59        0.12       -10.5          10           3
          200        7.6        -8.6             0.84         0.21        0.70        0.11       -10.5          10           3
          250        9.5        -8.3             0.98         0.24        0.80        0.13       -10.5          10           3
          300       11.0        -8.1             1.04         0.26        0.89        0.15       -10.5          10           3
          350       12.4        -7.9             1.18         0.31        0.96        0.13       -10.5          10           3
          400       13.6        -7.6             1.28         0.35        1.03        0.19       -10.5          10           3
          450       14.7        -7.4             1.39         0.38        1.11        0.22       -10.5          10           3
          500       15.6        -7.2             1.44         0.39        1.20        0.19       -10.5          10           3
          550       16.3        -7.0             1.55         0.46        1.24        0.23       -10.5          10           3
          600       17.2        -6.9             1.59         0.43        1.29        0.23       -10.5          10           3
          650       18.1        -6.9             1.67         0.34        1.35        0.22       -10.5          10           3
          700       18.5        -6.8             1.67         0.42        1.41        0.15       -10.5          10           3
          750       19.1        -6.3             1.87         0.54        1.46        0.25       -10.5          10           3
          800       19.6        -6.3             1.90         0.46        1.51        0.25       -10.5          10           3
          850       20.1        -6.0             1.99         0.60        1.56        0.27       -10.5          10           3
          900       20.8        -5.8             2.14         0.60        1.63        0.29       -10.5          10           3
          950       21.1        -5.6             2.22         0.60        1.66        0.33       -10.5          10           3
         1000       21.6        -5.6             2.23         0.61        1.71        0.30       -10.5          10           3

Sample calculation
  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  distance correction = -20 * LOG (dLimit/ dused)
  Linear interpolation will be used for frequencies in between the values in the table.
  Tables show an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                                                Page 23 of 28


6.4    ANTENNA R&S HF907 (1 GHZ – 18 GHZ)
                                                                       cable
                                               cable                   loss 3
                                              loss 1                  (switch
                                             (relay +      cable        unit,
                  AF                           cable       loss 2     atten-        cable
                 R&S                          inside      (outside    uator &     loss 4 (to
  Frequency     HF907        Corr.          chamber)     chamber)    pre-amp)     receiver)
     MHz       dB (1/m)       dB                dB           dB          dB           dB
       1000        24.4       -19.4               0.99        0.31      -21.51         0.79
       2000        28.5       -17.4               1.44        0.44      -20.63         1.38
       3000        31.0       -16.1               1.87        0.53      -19.85         1.33
       4000        33.1       -14.7               2.41        0.67      -19.13         1.31
       5000        34.4       -13.7               2.78        0.86      -18.71         1.40
       6000        34.7       -12.7               2.74        0.90      -17.83         1.47
       7000        35.6       -11.0               2.82        0.86      -16.19         1.46

                                                                                    cable
                                                                                    loss 4
                                               cable                               (switch
                                              loss 1       cable       cable         unit,                  used
                  AF                          (relay       loss 2      loss 3      atten-        cable      for
                 R&S                          inside      (inside     (outside     uator &     loss 5 (to   FCC
  Frequency     HF907        Corr.          chamber)     chamber)    chamber)     pre-amp)     receiver)    15.247
     MHz       dB (1/m)       dB                dB           dB          dB           dB           dB
       3000        31.0       -23.4               0.47        1.87        0.53       -27.58         1.33
       4000        33.1       -23.3               0.56        2.41        0.67       -28.23         1.31
       5000        34.4       -21.7               0.61        2.78        0.86       -27.35         1.40
       6000        34.7       -21.2               0.58        2.74        0.90       -26.89         1.47
       7000        35.6       -19.8               0.66        2.82        0.86       -25.58         1.46

                                               cable
                                              loss 1      cable        cable        cable        cable         cable
                  AF                          (relay      loss 2       loss 3       loss 4       loss 5       loss 6
                 R&S                          inside      (High         (pre-      (inside      (outside        (to
  Frequency     HF907        Corr.          chamber)      Pass)        amp)       chamber)     chamber)     receiver)
     MHz       dB (1/m)       dB                dB          dB            dB          dB           dB           dB
       7000        35.6       -57.3               0.56       1.28        -62.72        2.66         0.94          1.46
       8000        36.3       -56.3               0.69       0.71        -61.49        2.84         1.00          1.53
       9000        37.1       -55.3               0.68       0.65        -60.80        3.06         1.09          1.60
      10000        37.5       -56.2               0.70       0.54        -61.91        3.28         1.20          1.67
      11000        37.5       -55.3               0.80       0.61        -61.40        3.43         1.27          1.70
      12000        37.6       -53.7               0.84       0.42        -59.70        3.53         1.26          1.73
      13000        38.2       -53.5               0.83       0.44        -59.81        3.75         1.32          1.83
      14000        39.9       -56.3               0.91       0.53        -63.03        3.91         1.40          1.77
      15000        40.9       -54.1               0.98       0.54        -61.05        4.02         1.44          1.83
      16000        41.3       -54.1               1.23       0.49        -61.51        4.17         1.51          1.85
      17000        42.8       -54.4               1.36       0.76        -62.36        4.34         1.53          2.00
      18000        44.2       -54.7               1.70       0.53        -62.88        4.41         1.55          1.91

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  Linear interpolation will be used for frequencies in between the values in the table.
  Tables show an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                                                 Page 24 of 28


6.5    ANTENNA EMCO 3160-09 (18 GHZ – 26.5 GHZ)
                                              cable        cable      cable         cable       cable
                  AF                          loss 1      loss 2      loss 3       loss 4      loss 5
                EMCO                         (inside       (pre-     (inside      (switch        (to
  Frequency    3160-09       Corr.          chamber)      amp)      chamber)        unit)    receiver)
     MHz       dB (1/m)       dB                dB          dB          dB           dB          dB
      18000        40.2       -23.5              0.72      -35.85        6.20         2.81         2.65
      18500        40.2       -23.2              0.69      -35.71        6.46         2.76         2.59
      19000        40.2       -22.0              0.76      -35.44        6.69         3.15         2.79
      19500        40.3       -21.3              0.74      -35.07        7.04         3.11         2.91
      20000        40.3       -20.3              0.72      -34.49        7.30         3.07         3.05
      20500        40.3       -19.9              0.78      -34.46        7.48         3.12         3.15
      21000        40.3       -19.1              0.87      -34.07        7.61         3.20         3.33
      21500        40.3       -19.1              0.90      -33.96        7.47         3.28         3.19
      22000        40.3       -18.7              0.89      -33.57        7.34         3.35         3.28
      22500        40.4       -19.0              0.87      -33.66        7.06         3.75         2.94
      23000        40.4       -19.5              0.88      -33.75        6.92         3.77         2.70
      23500        40.4       -19.3              0.90      -33.35        6.99         3.52         2.66
      24000        40.4       -19.8              0.88      -33.99        6.88         3.88         2.58
      24500        40.4       -19.5              0.91      -33.89        7.01         3.93         2.51
      25000        40.4       -19.3              0.88      -33.00        6.72         3.96         2.14
      25500        40.5       -20.4              0.89      -34.07        6.90         3.66         2.22
      26000        40.5       -21.3              0.86      -35.11        7.02         3.69         2.28
      26500        40.5       -21.1              0.90      -35.20        7.15         3.91         2.36

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  Linear interpolation will be used for frequencies in between the values in the table.
  Table shows an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                                                Page 25 of 28


6.6    ANTENNA EMCO 3160-10 (26.5 GHZ – 40 GHZ)
                                              cable        cable        cable       cable    distance      dLimit       dused
                  AF                          loss 1       loss 2      loss 3      loss 4      corr.      (meas.       (meas.
                EMCO                         (inside      (outside    (switch        (to     (-20 dB/    distance     distance
  Frequency    3160-10       Corr.          chamber)     chamber)       unit)    receiver)   decade)      (limit)      (used)
     GHz       dB (1/m)       dB                dB           dB          dB          dB         dB           m           m
       26.5        43.4       -11.2                4.4                                          -15.6             3         0.5
       27.0        43.4       -11.2                4.4                                          -15.6             3         0.5
       28.0        43.4       -11.1                4.5                                          -15.6             3         0.5
       29.0        43.5       -11.0                4.6                                          -15.6             3         0.5
       30.0        43.5       -10.9                4.7                                          -15.6             3         0.5
       31.0        43.5       -10.8                4.7                                          -15.6             3         0.5
       32.0        43.5       -10.7                4.8                                          -15.6             3         0.5
       33.0        43.6       -10.7                4.9                                          -15.6             3         0.5
       34.0        43.6       -10.6                5.0                                          -15.6             3         0.5
       35.0        43.6       -10.5                5.1                                          -15.6             3         0.5
       36.0        43.6       -10.4                5.1                                          -15.6             3         0.5
       37.0        43.7       -10.3                5.2                                          -15.6             3         0.5
       38.0        43.7       -10.2                5.3                                          -15.6             3         0.5
       39.0        43.7       -10.2                5.4                                          -15.6             3         0.5
       40.0        43.8       -10.1                5.5                                          -15.6             3         0.5

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  Linear interpolation will be used for frequencies in between the values in the table.
  distance correction = -20 * LOG (dLimit/ dused)
  Linear interpolation will be used for frequencies in between the values in the table.
  Table shows an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                                                Page 26 of 28


7 SETUP DRAWINGS


_____________

Setup Drawings
_____________




Setup in the Anechoic chamber. For measurements below 1 GHz the ground was replaced by a
conducting ground plane.




                LISN                          Analyzer




                                              Signaling
                 EUT
                                                UNIT
Setup in the shielded room for conducted measurements at AC mains port

 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                                  Page 27 of 28


8 MEASUREMENT UNCERTAINTIES


   Test Case                                  Parameter        Uncertainty
   Conducted Emissions at AC mains            Voltage          ± 3.4 dB

   Radiated Emissions                         Field Strength   ± 5.5 dB




9 PHOTO REPORT

Please see separate photo report.




 TEST REPORT REFERENCE: MDE_UBLOX_1807_FCCd                               Page 28 of 28



Document Created: 2019-02-21 10:34:51
Document Modified: 2019-02-21 10:34:51

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC