Test Report LTE Spurious Emission Part 22

FCC ID: XPYTOBYL200

Test Report

Download: PDF
FCCID_2424584

                              PARTIAL FCC TEST REPORT
                                                                (PART 22)

                                         REPORT NO.: RF140820C14A
                                            MODEL NO.: TOBY-L200
                                                     FCC ID: XPYTOBYL200
                                              RECEIVED: Sep. 13, 2014
                                                   TESTED: Sep. 13, 2014
                                                   ISSUED: Sep. 30, 2014




                                APPLICANT: u-blox GMBH

                                   ADDRESS: Zürcherstrasse 68, CH-8800 Thalwil, Switzerland



                                 ISSUED BY: Bureau Veritas Consumer Products Services
                                            (H.K.) Ltd., Taoyuan Branch

                          LAB ADDRESS: No. 47, 14th Ling, Chia Pau Vil., Lin Kou Dist., New
                                       Taipei City, Taiwan ( R.O.C. )

                      TEST LOCATION: No. 19, Hwa Ya 2nd Rd, Wen Hwa Tsuen, Kwei
                                     Shan Hsiang, Taoyuan Hsien 333, Taiwan, R.O.C.


   This report should not be used by the client to claim
   product certification, approval, or endorsement by TAF or
   any government agencies.




This report is for your exclusive use. Any copying or replication of this report to or for any other person or entity, or use of our name or trademark, is permitted
only with our prior written permission. This report sets forth our findings solely with respect to the test samples identified herein. The results set forth in this
report are not indicative or representative of the quality or characteristics of the lot from which a test sample was taken or any similar or identical product unless
specifically and expressly noted. Our report includes all of the tests requested by you and the results thereof based upon the information that you provided to us.
You have 60 days from date of issuance of this report to notify us of any material error or omission caused by our negligence, provided, however, that such
notice shall be in writing and shall specifically address the issue you wish to raise. A failure to raise such issue within the prescribed time shall constitute your
unqualified acceptance of the completeness of this report, the tests conducted and the correctness of the report contents. Unless specific mention, the
uncertainty of measurement has been explicitly taken into account to declare the compliance or non-compliance to the specification

    Report No.: RF140820C14A
    Reference No.: 140915C02                                                 1 of 16                                           Report Format Version 5.0.0


                                                TABLE OF CONTENTS
RELEASE CONTROL RECORD ................................................................................................................ 3
1 CERTIFICATION ................................................................................................................................... 4
2 SUMMARY OF TEST RESULTS ........................................................................................................... 5
  2.1 MEASUREMENT UNCERTAINTY ................................................................................................ 5
  2.2 TEST SITE AND INSTRUMENTS ................................................................................................. 6
3 GENERAL INFORMATION ................................................................................................................... 7
  3.1 GENERAL DESCRIPTION OF EUT .............................................................................................. 7
  3.2 CONFIGURATION OF SYSTEM UNDER TEST ........................................................................... 8
  3.3 DESCRIPTION OF SUPPORT UNITS .......................................................................................... 8
  3.4 TEST ITEM AND TEST CONFIGURATION .................................................................................. 9
  3.5 EUT OPERATING CONDITIONS .................................................................................................. 9
  3.6 GENERAL DESCRIPTION OF APPLIED STANDARDS ............................................................... 9
4 TEST TYPES AND RESULTS ............................................................................................................. 10
  4.1 RADIATED EMISSION MEASUREMENT ................................................................................... 10
      4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT ...................................................... 10
      4.1.2 TEST PROCEDURES ....................................................................................................... 10
      4.1.3 DEVIATION FROM TEST STANDARD ............................................................................. 10
      4.1.4 TEST SETUP .................................................................................................................... 11
      4.1.5 TEST RESULTS ................................................................................................................ 12
5 PHOTOGRAPHS OF THE TEST CONFIGURATION ......................................................................... 14
6 INFORMATION ON THE TESTING LABORATORIES ....................................................................... 15
7 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING CHANGES TO THE EUT BY
  THE LAB .............................................................................................................................................. 16




Report No.: RF140820C14A
Reference No.: 140915C02                                                2 of 16                                          Report Format Version 5.0.0


                              RELEASE CONTROL RECORD

ISSUE NO.             REASON FOR CHANGE                      DATE ISSUED
RF140820C14A          Original release                       Sep. 30, 2014




Report No.: RF140820C14A
Reference No.: 140915C02                  3 of 16      Report Format Version 5.0.0


1 CERTIFICATION

                 PRODUCT: GSM/UMTS/HSPA/LTE Data Module
                    MODEL: TOBY-L200
                    BRAND: ublox
               APPLICANT: u-blox GMBH
                   TESTED: Sep. 13, 2014
           TEST SAMPLE: Production Unit
             STANDARDS: FCC PART 22, Subpart H



The above equipment (model: TOBY-L200) has been tested by Bureau Veritas
Consumer Products Services (H.K.) Ltd., Taoyuan Branch, and found compliance
with the requirement of the above standards. The test record, data evaluation &
Equipment Under Test (EUT) configurations represented herein are true and accurate
accounts of the measurements of the sample’s EMC characteristics under the
conditions specified in this report.




   PREPARED BY             :                                        , DATE :     Sep. 30, 2014
                                     Evonne Liu / Specialist


   APPROVED BY             :                                        , DATE :     Sep. 30, 2014
                               Sam Chen / Senior Project Engineer




Report No.: RF140820C14A
Reference No.: 140915C02                          4 of 16                      Report Format Version 5.0.0


2      SUMMARY OF TEST RESULTS
The EUT has been tested according to the following specifications:


                             APPLIED STANDARD: FCC Part 22 & Part 2

    STANDARD
     SECTION                  TEST TYPE                   RESULT                  REMARK

      21053                                                        Mggt the requill'ement of Iimit.
      22917           Radiated Spurious Emissions          PASS    [Minimum passing margin is
        '                                                          —33.000B at 1673.00MHz.




2.1    MEASUREMENT UNCERTAINTY
Where relevant, the following measurement uncertainty levels have been estimated for tests performed
on the EUT as specified in CISPR 16—4—2:


        MEASUREMENT                         FREQUENCY                           UNCERTAINTY
                                           30MHz ~ 200MHz                            2.93 dB
                                        200MHz ~1000MHz                              2.95 dB
        Radiated emissions
                                            1GHz ~18GHz                              2.26 dB
                                           18GHz ~ 40GHz                             1.94 dB
This uncertainty represents an expanded uncertainty expressed at approximately the 95% confidence
level using a coverage factor of k=2.




Report No.: RF140820C14A
Reference No.: 140915002                        5 of 16                             Report Format Version 5.0.0


2.2 TEST SITE AND INSTRUMENTS
    DESCRIPTION &                                                      DATE OF         DUE DATE OF
                                MODEL NO.            SERIAL NO.
    MANUFACTURER                                                     CALIBRATION       CALIBRATION
Test Receiver
                                    ESCI                  100744      Apr. 15, 2014     Apr. 14, 2015
ROHDE & SCHWARZ
Spectrum Analyzer
                                   FSU43                  101261      Dec. 21, 2013     Dec. 20, 2014
ROHDE & SCHWARZ
BILOG Antenna
                                 VULB9168                9168-472     Feb. 27. 2014     Feb. 26, 2015
SCHWARZBECK
HORN Antenna
                               BBHA 9120 D               9120D-969    Feb. 19, 2014     Feb. 18, 2015
SCHWARZBECK
HORN Antenna
                                BBHA 9170                9170-480     Dec. 18, 2013     Dec. 17, 2014
SCHWARZBECK
Preamplifier
                                EMC 012645                980115      Dec. 26, 2013     Dec. 25, 2014
EMCI
Preamplifier
                                EMC 184045                980116      Jan. 13, 2014     Jan. 12, 2015
EMCI
Preamplifier
                                 EMC 330H                 980112      Dec. 27, 2013     Dec. 26, 2014
EMCI
RF signal cable                                          309219/4
                              SUCOFLEX 104                            Oct. 18, 2013     Oct. 17, 2014
HUBER+SUHNNER                                            2950114
RF signal cable
                              SUCOFLEX 104               250130/4     Oct. 18, 2013     Oct. 17, 2014
HUBER+SUHNNER
RF signal cable
                                  RG-213                    NA        Nov. 07, 2013     Nov. 06, 2014
Worken
Software                             E3
                                                            NA             NA                 NA
BV ADT                            6.120103
Antenna Tower
                                 MFA-440H                   NA             NA                 NA
MF
Turn Table
                                MFT-201SS                   NA             NA                 NA
MF
Antenna Tower &Turn Table
Controller                        MF-7802                   NA             NA                 NA
MF
                            2-18GHz 2Way SMA
Power Splitter
                             Fwd.:30W/Rev.:2W      COM412W5E3         Apr. 17, 2014     Apr. 16, 2015
Woken
                               Isolated Power
JFW 20dB attenuation          50HF-020-SMA                 NA               NA                 NA
Communications
                                    E5515C            MY52102544       Sep. 11, 2014     Sep. 10, 2015
Tester-Wireless
Radio Communication
                                   MT8820C            6201300640       Aug. 01, 2013 Jul. 31, 2015
Analyzer
NOTE: 1. The calibration interval of the above test instruments is 12 months and the calibrations are
            traceable to NML/ROC and NIST/USA.
        2. The test was performed in HwaYa Chamber 10.
        3. The horn antenna and HP preamplifier (model: 8449B) are used only for the measurement of
            emission frequency above 1GHz if tested.
        4. The FCC Site Registration No. is 690701.
        5. The IC Site Registration No. is IC 7450F-10.




Report No.: RF140820C14A
Reference No.: 140915C02                       6 of 16                          Report Format Version 5.0.0


3 GENERAL INFORMATION

3.1 GENERAL DESCRIPTION OF EUT
EUT                         GSM/UMTS/HSPA/LTE Data Module
MODEL NO.                   TOBY-L200
POWER SUPPLY                12Vdc (adapter)
MODULATION TYPE             QPSK, 16QAM
FREQUENCY RANGE             829MHz ~ 844MHz
ANTENNA TYPE                PCB Antenna
I/O PORTS                   Refer to users’ manual
DATA CABLE                  Refer to NOTE as below
ACCESSORY DEVICES           Refer to NOTE as below

NOTE:
1. The above EUT information was declared by manufacturer and for more detailed features description,
   please refer to the manufacturer's specifications or User's Manual.




Report No.: RF140820C14A
Reference No.: 140915C02                       7 of 16                         Report Format Version 5.0.0


3.2 CONFIGURATION OF SYSTEM UNDER TEST




                                                           EUT     (Powered from adapter)


                                           Antenna
      Test table



                                           Radio
                                        Communication
                                          Analyzer




      Kept in a remote area



3.3 DESCRIPTION OF SUPPORT UNITS
The EUT has been tested as an independent unit together with other necessary accessories or support
units. The following support units or accessories were used to form a representative test configuration
during the tests.


NO.       PRODUCT             BRAND       MODEL NO.            SERIAL NO.                   FCC ID
  1         Antenna             N/A            N/A                  N/A                       N/A
  2         Adapter           UNIFIVE      UUX324-1215              N/A                       N/A
          Radio
  3    Communication          Anritsu       MT8820C              6201240431                   N/A
         Analyzer

NO.                   SIGNAL CABLE DESCRIPTION OF THE ABOVE SUPPORT UNITS
  1   N/A
  2   1.55m cable
NOTE:
1. All power cords of the above support units are non shielded (1.8m).
2. Items 1&2 were provided by client.




Report No.: RF140820C14A
Reference No.: 140915C02                        8 of 16                            Report Format Version 5.0.0


3.4 TEST ITEM AND TEST CONFIGURATION
Pre-Scan has been conducted to determine the worst-case mode from all possible combinations between
available modulations, data rates, XYZ axis and antenna ports. Following channel(s) was (were) selected
for the final test as listed below:


LTE BAND 5 MODE
   EUT
                               AVAILABLE                          CHANNEL
CONFIGURE      TEST ITEM                       TESTED CHANNEL                  MODULATION              MODE
                                CHANNEL                          BANDWIDTH
  MODE
               RADIATED
     -                        20450 to 20600        20525          10MHz          QPSK           1 RB / 24 RB Offset
               EMISSION
Note: This device was tested under all bandwidths, RB configurations and modulations. The worst case
was found in QPSK modulation.


TEST CONDITION:

             TEST ITEM                 ENVIRONMENTAL CONDITIONS            INPUT POWER            TESTED BY

         RADIATED EMISSION                     25deg. C, 65%RH             120Vac, 60Hz             Will Chen




3.5 EUT OPERATING CONDITIONS
The EUT makes a call to the communication simulator. The communication simulator station system
controlled a EUT to export maximum output power under transmission mode and specific channel
frequency


3.6 GENERAL DESCRIPTION OF APPLIED STANDARDS
The EUT is a RF product. According to the specifications of the manufacturer, it must comply with the
requirements of the following standards:


FCC 47 CFR Part 2
FCC 47 CFR Part 22
ANSI/TIA/EIA-603-C 2004


NOTE: All test items have been performed and recorded as per the above standards.




Report No.: RF140820C14A
Reference No.: 140915C02                             9 of 16                              Report Format Version 5.0.0


4      TEST TYPES AND RESULTS

4.1      RADIATED EMISSION MEASUREMENT
4.1.1 LIMITS OF RADIATED EMISSION MEASUREMENT
The power of any emission outside of the authorized operating frequency ranges must be attenuated
below the transmitting power (P) by a factor of at least 43 + 10 log(P) dB. The emission limit is equal to
—13dBm.


4.1.2 TEST PROCEDURES
a.   Substitution method is used for E.1.R.P measurement. in the semi—anechoic chamber, EUT placed on
     the 0.8m height of Turn Table, rotated the table around 360 degrees to search the maximum radiation
     power and receiver antenna shall be rotated vertical and horizontal polarization and moved height from
      1m to 4m to find the maximum polar radiated power. The "Read Value" is the spectrum reading the
     maximum power value.
     The substitution horn antenna is substituted for EUT at the same position and signals generator export
     the CW signal to the substitution antenna via a TX cable. Rotated the Turn Table and moved receiving
     antenna to find the maximum radiation power. Adjust output power level of S.G to get a Value of
     spectrum reading equal to "Read Value" of step a. Record the power level of S.G
     EIRP = Output power level of S.G — TX cable loss + Antenna gain of substitution horn.
      E.R.P power can be calculated form E.1.R.P power by subtracting the gain of dipole, E.R.P power =
      E.1.R.P power — 2.15dBi.


NOTE: The resolution bandwidth and video bandwidth of test receiver/spectrum analyzer is 1MHz/3MHz.


4.1.3 DEVIATION FROM TEST STANDARD
No deviation




Report No.: RF140820C14A
Reference No.: 140915002                          10 of 16                          Report Format Version 5.0.0


4.1.4 TEST SETUP




For the actual test configuration, please refer to the attached file (Test Setup Photo).




Report No.: RF140820C14A
Reference No.: 140915C02                          11 of 16                           Report Format Version 5.0.0


4.1.5 TEST RESULTS
LTE BAND 5
CHANNEL BANDWIDTH: 10MHz / QPSK




Report No.: RF140820C14A
Reference No.: 140915C02          12 of 16   Report Format Version 5.0.0


        Level(dBm/m)                                                                          Date: 2014—08—13


     ~10.0                                                                                      PART 22024
                                                                                                      —6dB
     20.0

     30.0


     40.0


     —50.0    2                         7
                  3
     60.0                       6

                           5
     —70.0            4



             30                        1824.               3618.             B412.    (206,              9000
                                                               Frequency (MHz)


Site      : 966 chamber 5
Condition: PART 22/24 3m Vertical
Remark                : LTE_Band 5_QPSK(1,24)_10M_CH20525
Tested by: Will Chen
                                              Read    Limit      Over
                      Freq          Level    Level      Line    Limit Factor Remark

                          MHz       dBm/m      dBm   dBm/m        dB    dB/m

 1 pp          46.47            —47.25      —34.45   —13.00    —34.25 —12.80 Peak
 2            133.68            —53.71      —46.05   —13.00    —40.71 —7.66 Peak
 3            202.53            —56.82      —50.68   —13.00    —43.82 —6.14 Peak
 4            393.80            —71.49      —68.44   —13.00    —58.49 —3.05 Peak
 5            696.20 —67.75 —67.39 —13.00 —54.75                       —0.36 Peak
 6            966.40 —63.19 —68.35 —13.00 —50.19                        5.16 Peak
 7           1673.00 —52.20 —60.11 —13.00 —39.20                         7.91 Peak


5 PHOTOGRAPHS OF THE TEST CONFIGURATION
Please refer to the attached file (Test Setup Photo).




Report No.: RF140820C14A
Reference No.: 140915C02                         14 of 16   Report Format Version 5.0.0


6 INFORMATION ON THE TESTING LABORATORIES
We, Bureau Veritas Consumer Products Services (H.K.) Ltd., Taoyuan Branch, were founded in 1988 to
provide our best service in EMC, Radio, Telecom and Safety consultation. Our laboratories are accredited
and approved according to ISO/IEC 17025.


If you have any comments, please feel free to contact us at the following:


Linko EMC/RF Lab:                                     Hsin Chu EMC/RF/Telecom Lab:
Tel: 886-2-26052180                                   Tel: 886-3-5935343
Fax: 886-2-26051924                                   Fax: 886-3-5935342


Hwa Ya EMC/RF/Safety Lab:
Tel: 886-3-3183232
Fax: 886-3-3270892

Email: service.adt@tw.bureauveritas.com
Web Site: www.bureauveritas-adt.com


The address and road map of all our labs can be found in our web site also.




Report No.: RF140820C14A
Reference No.: 140915C02                        15 of 16                        Report Format Version 5.0.0


7 APPENDIX A – MODIFICATIONS RECORDERS FOR ENGINEERING
  CHANGES TO THE EUT BY THE LAB
No any modifications were made to the EUT by the lab during the test.




---END---




Report No.: RF140820C14A
Reference No.: 140915C02                       16 of 16                 Report Format Version 5.0.0



Document Created: 2014-09-30 09:30:19
Document Modified: 2014-09-30 09:30:19

© 2024 FCC.report