Test report

FCC ID: XPYLISAU200

Test Report

Download: PDF
FCCID_2140519

                                   PARTIAL - T E S T R E P O R T
                                       No.: 6-0330-13-3-6a



                                                       According to:
                                                    FCC Regulations
                                           Part 15C, Part 22, Part 24 & Part 27
                                                     IC-Regulations
                                    RSS-132 Issue 3, RSS-133 Issue 6, RSS-139 Issue 2
                                                     RSS-Gen Issue 3




                                                             for

                                                     u-blox AG

                                        RF-Module LISA-U200-01
                                              FCC-ID: XPYLISAU200
                                              IC: 8595A-LISAU200N


                                           Laboratory Accreditation and Listings




                                                                            Industry Canada       Voluntary Controls for
                                                                                               Electromagnetic Emissions
                                                                           Reg. No.: 3462D-1
                                                     Reg. No.: 736496      Reg. No.: 3462D-2   Reg. No.: R-2665, R-2666
                                                     MRA US-EU 0003        Reg. No.: 3462D-3    C-2914, T-1967, G-301




                                     accredited according to DIN EN ISO/IEC 17025


                                                     CETECOM GmbH
                              Laboratory Radio Communications & Electromagnetic Compatibility
                                          Im Teelbruch 116 • 45219 Essen • Germany
                                 Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                               Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                   E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                    Page 1 of 31
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without
the written approval of the testing laboratory                                  © Copyright: All rights reserved by CETECOM


Test Report 6-0330-13-3-6a, Page 2 of 31


Table of contents
1. SUMMARY OF TEST RESULTS...................................................................................................................... 3
  1.1. TX mode, tests overview of US CFR (FCC) and Canada IC (RSS) Standards ............................................... 3
2. ADMINISTRATIVE DATA ............................................................................................................................... 4
  2.1. Identification of the testing laboratory ............................................................................................................. 4
  2.2. Test location .................................................................................................................................................... 4
  2.3. Organizational items ........................................................................................................................................ 4
  2.4. Applicant’s details ........................................................................................................................................... 4
  2.5. Manufacturer’s details ..................................................................................................................................... 4
3. EQUIPMENT UNDER TEST (EUT) ................................................................................................................. 5
  3.1. Technical data of main EUT declared by applicant ......................................................................................... 5
  3.2. EUT: Type, S/N etc. and short descriptions used in this test report ................................................................ 6
  3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions .................................................................. 6
  3.4. EUT set-ups ..................................................................................................................................................... 6
  3.5. EUT operating modes ...................................................................................................................................... 7
  3.6. Parameter Settings on mobile phone and base station CMU200 ..................................................................... 8
4. DESCRIPTION OF TEST SYSTEM SET-UP’S .............................................................................................. 10
  4.1. Test system set-up for conducted RF-measurement at antenna port ................................................................ 10
  4.2. Test system set-up for radiated magnetic field measurements below 30 MHz ................................................ 11
  4.3. Test system set-up for radiated spurious emission measurements ................................................................... 12
5. MEASUREMENTS ............................................................................................................................................. 13
  5.1. RF Parameter – Power Conducted and Radiated - E.I.R.P. ............................................................................. 13
  5.2. Radiated field strength emissions below 30 MHz ........................................................................................... 17
  5.3. RF Paramater - Radiated out of Band RF emissions ....................................................................................... 23
  5.4. Measurement uncertainties .............................................................................................................................. 26
6. ABBREVIATIONS USED IN THIS REPORT ................................................................................................. 26
7. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES ......................... 27
8. INSTRUMENTS AND ANCILLARY ................................................................................................................ 27
  8.1. Used equipment “CTC” ................................................................................................................................... 27


Table of annex                                                                                                                                        Total pages


ANNEX 1: MEASUREMENT DIAGRAMS                                                                                                                                        42
ANNEX 2: INTERNAL PHOTOGRAPHS OF EUT (TO BE SUPPLIED BY CUSTOMER)                                                                                                     --
ANNEX 3: EXTERNAL PHOTOGRAPHS OF EUT                                                                                                                                   5
ANNEX 4: TEST SET-UP PHOTOGRAPHS                                                                                                                                       4
ANNEX 5: PRODUCT LABEL                                                                                                                                                 1
ANNEX 6:DECLARATION OF IDENTICAL PRODUCTS                                                                                                                              1

The listed attachments are an integral part of this report.




TR6-0330-13-3-6a


                                                                                                                                                          Tm

Test Report 6—0330—13—3—64, Page 3 of 31                                                                                            c’”g OM




1. Summary of test results

The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH does
not assume responsibility for any conclusions and generalizations taken in conjunction with other specimens or
samples of the type of the item presented to tests.

The Equipment Under Test (in this report, hereinafter referred as EUT) supports radiofrequency technologies.
This test report shows results for GSM/(E)GPRS Band 850 and 1900, W—CDMA Band II, IV and V technologies
only. Other implemented wireless technologies were not considered within this test report.

Following tests have been performed to show compliance with applicable FCC Part 2, Part 22, Subpart H, Part
24, Subpart E (Broadband PCS) and Part 27, Subpart C of the FCC CFR 47 Rules, annual Edition 1" October
2013 and Canada RSS—132 Issue 3, RSS—133 Issue 6, RSS—139 issue 2 and RSS—Gen Issue 3 standards.



1.1. TX mode, tests overview of US CFR (FCC)and Canada IC (RSS) Standards
  No. of                                                                      References & Limits                                       EUT
Diagram                ge“               Port                                                                                PUY         op—     Result
 chapter                ases                       FCC Standard                 RSS Section                 Test limit      SSH0P       mode
                   Emissions                                                                           §15.207 limits
   _          AC—Power lines          AC—Power           §15.207              RSS—Gen, Issue 3:                               _           _      Remark
               0,15—30 MHz              lines               "                   Chapter7.2.4            IC: Table 4,                               1.)
                conducted                                                                              Chapter 7.2.4
                                                                                                                                        1+3+
                                                                                                                                        3 + 4+
   —               fr foust
                   conducted
                                       Chind
                                       terminal
                                                         §g2.1046                     se                      NA              2         5+6+     passed
                                                                                                                                        7+ 8+
                                                                                                                                        9+ 10
                                                                                RSS—132: 5.4+
                   RF—Power                              §2.1046               sRsp—503: 5.13         <7 Wat (ERP)                      {48%
                (ERP/EIRP)                    4    §22.913(a)(2)              RSS—133:4.1/6.4+
   =                                   Cabinet      "yp4g32(.)                 srspsi0si2             ~*Wet(ERP)               _1       4+5+ passed
                   radiated                          27.50(d)(4                RSS—139: 6.4+
                                                   275000                      chspspsiz              <!Wet(ERP)
   ~           261]:“"51“:/‘;;5:%      Antenna        §§22i20(3129                                                                               Remark
                   o
                         &     s
                                              j
                                       terminal
                                                     395
                                                     §22.917(a)
                                                                               RSS/Gen:4.6.1            99% Power             «—          —       pra
                                                                                                                                                   L)
               99% Occupied                          §24.238(a)
                 bandwith                                "
                                                         §2.1051
             Spurious emissions        ARtenna           §2.1057             RSS—132: 4.5.1                                             1+5+
  36x              ondupion            lcrminal     §229!7@(b)               RSS—133:6.5.1(@)(b)      43+1010g(P) dBc          1        4+ 5+    passed
                                                    §24.238(a)(b)            RSS—139: 6.5(i)(ii)                                         6+7
                                                    §27.53(G)
                General field                                                   c];:sx_c??i 1       2400/r(H2)puv/imz
  2.x        strength emissions                      §15.209(a)                     ¥      f        4000/F(kHz) pV/m           1                 passed
                                          .                                  Chapter 7.2.5, Table
             (9 kHz — 30 MHz)         Cabinet +                                      5+6            30 pV/m                             f4%+
                                        Inter—       g                                     ,
             Spurious emissions        connect       §2,1053(a)                   RSS—132:                                              4+ 3+
   8.x
                   radiated             cables           y21087
                                                   §22.917(a)(b)
                                                                                451 & 452
                                                                                 RSS—133:
                                                                                                     43+10log(P) dBc           1
                                                                                                                                        £+7      passed
                                                   §24.238(@)(b)                 6.5.1(a)(b)
                                                    §27.53(h)(3)              RSS—139:6.50)Gi)
                                                   §2.1055@)(2)                         .               f
             Frequency stability       Antenna     §22.355,                     RSS'13214'3               a2opein                                Remark
   x             conducted
                                            *
                                       terminal      table C—1
                                                                                RSS—133:  6.3
                                                                                RSS—139: 63
                                                                                                        <0.1
                                                                                                        <20.1
                                                                                                              ppm             x           x        1
                                                  §24.235, §27.54                   TCO                        " PP
General remark: GSM/(E)GPRS Band 850 and 1900 and the FDD bands 2/ 4/ 5 only partial done. Duc to customer
                declaration RF module LISA—U200—01 is based on parent module ofcertified LISA—U200. Please refer at
                       annex 6 the declaration ofidentical products. Therefore spot—check tests are performed.
Remark: 1.) Those tests already performed for the new activated FDD 4 band. Please refer ‘TR6—0143—12—11—2a°.

         A                                                                                                                          4



             si——
Dipl.—Ing. Ch. Lorenz
                                                             CEkeom"
                                                                   i        GmbH
                                                                                                              _23          Dipl—Ing. B. Taslica
Responsible for test section                           wl              Z’rzef'gbruch 116                                 ponsible for test report
                                                              v       Es
                                                                      E
                                                                         sen
                                                      _Tel:+49 (C
                                                                  ) 20 54 / 95 19
                                                       ay:                        — 0
TR6—0330—13—3—6a                                             +498 (0} 8084788 15 . es


Test Report 6-0330-13-3-6a, Page 4 of 31




2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                         CETECOM GmbH
Address:                                                              Im Teelbruch 116
                                                                      45219 Essen - Kettwig
                                                                      Germany
Responsible for testing laboratory:                                   Dipl.-Ing. N. Jeß
Deputy:                                                               Dipl.-Ing. R. Acharkaoui



2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                         see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Responsible for test report and
project leader:                                                       Dipl.-Ing. B. Taslica
Receipt of EUT:                                                       2013-06-03
Date(s) of test:                                                      2013-10-17- 2013-10-18
Date of report:                                                       2013-10-19
       -----------------------------------------------------------------------------------------------------------------------------------------------------

Version of template:             12.08 ,Bircan [CETECOM]
2.4. Applicant’s details

Applicant’s name:                                                     u-blox AG
Address:                                                              Zürcherstrasse 68
                                                                      8800 Thalwil

                                                                      Switzerland
Contact person:                                                       Mr. Giulio Comar

2.5. Manufacturer’s details

Manufacturer’s name:                                                  please see Appllicant's details

Address:                                                              please see Appllicant's details




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 5 of 31




3. Equipment under test (EUT)
3.1. Technical data of main EUT declared by applicant
Main function                          GSM/GPRS/WCDMA RF Module (Data/Voice)
Type                                   LISA-U200-01-01
GSM/FDD Frequency range                GSM 850: 824 – 849 MHz (Uplink), 869-894 MHz (Downlink)
(US/Canada -bands)                     GSM1900: 1850-1910 MHz (Uplink), 1930-1990 MHz (Downlink)
                                       FDD Band 2: 1852.4–1907.6 MHz (Uplink), 1930-1990MHz (Downlink)
                                       FDD Band 4: 1712.4–1752.6 MHz (Uplink), 2110-2155MHZ (Downlink)
                                       FDD Band 5: 826.4-846.6 MHz (Uplink), 869-894MHz (Downlink)
Type of modulation                     GSM, GPRS, GMSK
                                       EGPRS-Mode: 8-PSK
                                       FDD-Mode Release99: QPSK
                                       FDD Mode Release 5+6: DL 16 QAM, UL QPSK/BPSK additionally
Number of channels                     GSM 850: 128 – 251, 125 channels
(USA/Canada -bands)                    GSM1900: 512 – 810, 300 channels
                                       FDD Band 2: UARFCN range 9262 – 9400 – 9538
                                       FDD Band 4: UARFCN range 1312 – 1413 – 1513
                                       FDD Band 5: UARFCN range 4132 – 4183 – 4233
Antenna Type                            Integrated
                                        External, no RF- connector
                                        External, separate RF-connector
Antenna Gain                            radiated:.3.0 dBi average gain
Max. Output Power (conducted):
                         GSM 850 32.4 dBm (PK) / 32.2 dBm (AV)
                         EDGE 850 29.6 dBm (PK) / 27.0 dBm (AV)
Max. Output Power (radiated):
                          850 band 32.40 dBm (PK)

Max Output Power (conducted):
                       GSM 1900 29.1 dBm (PK) / 29.0 dBm (AV)
                       EDGE 1900 28.6 dBm (PK) / 25.8 dBm (AV)
Max Output Power (radiated):
                        1900 band 32.10 dBm (PK)

Max Output Power (radiated)
                        1700 band          29.2 dBm (PK)

Max Output Power (conducted)
             FDD-Mode 2                26.0 dBm (PK) / 22.6 dBm (AV)
             FDD-Mode 4                26.2 dBm (PK) / 22.9 dBm (AV)
             FDD-Mode 5                26.4 dBm (PK) / 23.1 dBm (AV)
FCC-ID                                 XPYLISAU200
IC                                     8595A-LISAU200N
Installed options                       GSM 900 and GSM 1800 Bands (not usable in USA/Canada)
                                        FDD VIII Bands (not usable in USA/Canada)
                                        W-LAN, Bluetooth© wireless technologies
                                        battery charging option
                                        GPS (not tested within this test report)
                                        FM-Radio (Receiver only)
                                        NFC (not tested within this test report)
Power supply                            3.8 V DC (nominal), 3.4 V DC (minimum) and 4.2 V DC (maximum)
                                        over AC/DC adapter: 120V/60 Hz

Lowest radio frequency signal          Master clock 26 MHz
EUT sample type                         Pre-Production
FCC label attached                      yes  no



TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 6 of 31


3.2. EUT: Type, S/N etc. and short descriptions used in this test report

Short
                                                                     S/N               HW                SW
descrip-               EUT                      Type
                                                                serial number     hardware status   software status
tion*)
EUT A               RF-Module            LISA-U200-01          IMEI: 358901-
                                                                                     146AB2                22.90
                                                                04-594324-5

EUT B              Adapter Board        LISA-U200 FAE                279         IP02_HW_CS_                --
                                                                                     150000
*) EUT short description is used to simplify the identification of the EUT in this test report.


3.3. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions

   AE
                                                                     S/N               HW                SW
  short      Auxiliary Equipment                Type
                                                                serial number     hardware status   software status
descrip-
 tion *)
  AE 1         Magnetic Mount           Taoglas GA.107                #1            Ant. Gain               --
                  Antenna
                                                                                      3.0 dBi

  AE 2         Amplus AC/DC
                Charger with
             additional ferrite on    NTS 30W EuP 5-12,
                AC-line (AC                                          #1                  --                 --
                                        max 4000mA
                120V/60Hz,
                     DC 12 V)

  AE 3              USB cable          Mini USB to USB                #1               1,8m                 --

  AE 4                Laptop                CTC #7                    --                 --                 --
*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.


3.4. EUT set-ups

EUT set-up
                         Combination of EUT and AE                                   Remarks
  no.*)

   Set. 1             EUT A + EUT B + AE 1 + AE 2 +                         Used only for radiated tests
                                (AE 3 + AE 4)                     (AE 3 + AE 4: used outside of the chamber)

   Set. 2                       EUT A + EUT B                              Used only for conducted tests
                                                                  (power supply cables at EUT A for nominal
                                                                                   voltage)
*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 7 of 31


3.5. EUT operating modes
GSM modes
   EUT
                    Description of
 operating                                                       Additional information
                   operating modes
mode no.*)

               GSM 850             A communication link is established between the mobile station and the
    op. 1
               TCH mode            test simulator. The transmitter is operated at its maximum rated output
               TCH=128/192/251     power: 33 dBm (power class 4; power control level 5).
                                   The input signal to the receiver is modulated with normal test modulation.
                                   The wanted RF input signal level to the receiver of the mobile station is set
                                   to a level to provide a stable communication link.
             EGPRS 850             A communication link is established between the mobile station and the
    op. 2
             TCH mode              test simulator. The transmitter is operated at its maximum rated output
             TCH=128/192/251 power: 33 dBm (power class 4; power control level 5). USF_Duty CYCLE
                                   set to 100%, coding scheme MCS-5 for 8PSK modulation, slot 3 active,
                                   uplink gamma: 6 (27dBm).
                                   The input signal to the receiver is modulated with normal test modulation.
                                   The wanted RF input signal level to the receiver of the mobile station is set
                                   to a level to provide a stable communication link.
             GSM 1900              A communication link is established between the mobile station and the
    op. 3
             TCH mode              test simulator. The transmitter is operated at its maximum rated output
             TCH=512/661/810 power: 30 dBm (power class 1; power control level 0).
                                   The input signal to the receiver is modulated with normal test modulation.
                                   The wanted RF input signal level to the receiver of the mobile station is set
                                   to a level to provide a stable communication link
             EGPRS 1900            A communication link is established between the mobile station and the
    op. 4
             TCH mode              test simulator. The transmitter is operated at its maximum rated output
             TCH=512/661/810 power: 30 dBm (power class 1; power control level 0). USF_Duty CYCLE
                                   set to 100%, coding scheme MCS-5 for 8-PSK modulation, slot 3 active,
                                   uplink gamma: 5 (26 dBm).
                                   The input signal to the receiver is modulated with normal test modulation.
                                   The wanted RF input signal level to the receiver of the mobile station is set
                                   to a level to provide a stable communication link.
*) EUT operating mode no. is used to simplify the test report.

FDD modes
               FDD-Mode 2
    op. 5
               12.2 kbps RMC          A communication link is established between the mobile station (UE) and
                                     the test simulator. The transmitter is operated on its maximum rated output
               FDD-Mode 4                                        power class: 24dBm.
    op. 6
               12.2 kbps RMC         The input signal to the receiver is modulated with normal test modulation.
                                     The wanted RF input signal level to the receiver of the mobile station is set
               FDD-Mode 5                to a level to provide a stable communication link according Table
    op. 7
                                           E5.1/Table E5.1A as described in 3GPP TS34.121, Annex E.
               12.2 kbps RMC

               FDD Mode 2
    op. 8
               HSUPA
                                     In addition to normal FDD-Mode, the UE was set to operate in HSDPA and
               FDD Mode 4
    op. 9                                                         HSUPA Mode too.
                                                   Chosen settings: 12.2kbps RMC + HSPA 34.108
               HSUPA
                                              This setting was chosen for all release 6 mobile equipment.
               FDD Mode 5
   op. 10
             HSUPA
*) EUT operating mode no. is used to simplify the test report.


TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 8 of 31


3.6. Parameter Settings on mobile phone and base station CMU200
Following settings apply to the MS during the measurements in GSM/GPRS/(E)GPRS-Mode only:
                   Parameter                                Traffic Mode                     Idle Mode
Traffic Channels mobile station (EUT)      GSM 850: TCHMS= 128/ 190 /251               --
                                           GSM 1900: TCHMS = 512 / 661 / 810
maximum power level (PCL)                  GSM 850: PCL = 5 (2 Watt)                   --
                                           GSM 1900: PCL = 0 (1 Watt)
Modulation                                 GSM/GPRS: GMSK-Modulation Scheme            --
                                           EDGE:         8-PSK Modulation Scheme
DTX                                        off                                         --
Bitstream                                  PRBS 2E9-1 (pseudo-random-sequence) –
                                           CCITT 0.153
Timeslot(s) in Uplink                      3
Hopping                                    off
Timeslot (slot mode)                       GSM-Mode: single
                                           GPRS-Mode: maximum allowed uplink
                                           slots no.     according MS class
MS slot class                              Class 12
Maximum data transmission rate, single     GSM:          9,6 kbit/s Slot
time slot                                  GPRS:         17,6 kbit/s Slot
                                           EDGE:         59,2 kBit/s Slot
Speech transcoding (Traffic Mode)          Full rate Version 1
Speed rate                                 130 Kb/s
Mode                                       BCCH and TCH
BCCH – base station (CMU,CMD)              GSM 850: 182
                                           GSM 1900: 651
TCH – base station (CMD, CMU)              auto
Power level TCH – base station (used       - 70 dBm
timeslot level)
Power level BCCH – base station            - 80 dBm
(control channel level)
External attenuation RF/AF-                Accord. calibration prior to measurements
Input/Output
Mobile Country Code                        310                                         310
Domain                                     PS
BS_AG_BLKS_RES                                                                         0
Paging reorganisation                                                                  Off (0)
Signalling channel                         Not applicable                              SDCCH
Location Update                                                                        Auto
Cell access                                                                            Disabled (barred)




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 9 of 31


Following settings apply to the UE (EUT) during the measurements in FDD-Mode only:
Parameter                                  Traffic Mode                              Idle Mode
UARFCN UE Uplink (EUT)            FDD 2 = 9262/ 9400/ 9538                           --
(according TS34.108)              FDD 4 = 1312/1413/1513
                                  FDD 5 = 4132/ 4182/ 4233
UARFCN Node B (downlink)          FDD 2 = 9663/ 9800/ 9937
(according TS34.108)              FDD 4 = 1537/1675/1738
                                  FDD 5 = 4358/ 4040/ 4457
UE power class                    Class 3 (+24dBm) nominal
HSDPA UE category/ HSUPA category 8/6
Maximum power                     FDD 2/4/5 12.2kbps RMC -> all TPC bits up (“1”)    --
                                  HSDPA-mode = accord. in 3GPP TS34.108
                                  HSUPA mode = accord. in 3GPP TS34.108
Modulation                        12.2kbps RMC-mode: (UL) QPSK-Modulation            --
                                  Scheme
                                  HSDPA/HSUPA= (UL) BPSK/QPSK,
                                  (DL) 16 QAM Modulation Scheme is applicable
Compression mode                  Off                                                --
Bitstream                         PRBS 2E9-1 (pseudo-random-sequence) – CCITT
                                  0.153
Maximum data transmission rate:   GSM: 17,6 kbps Slot
                                  EDGE: 59,2 kbps Slot
                                  FDD: QPSK 5,76 Mbps (UL)
                                        16 QAM 14,4 Mbps (DL)
Node B Downlink physical channels According Table E.5.1/E.5.1A in 3GPP TS34.121
settings
External attenuation RF/AF-       Accord. Set-up calibration prior to measurements
Input/Output




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 10 of 31



4. Description of test system set-up’s

4.1. Test system set-up for conducted RF-measurement at antenna port
Specification:               ANSI C63.10-2009

General Description:         The EUT‘s RF-signal is first attenuated before it is connected to the spectrum –
                             analyzer to avoid overload. The specific attenuation is determined prior to the
                             measurement within a set-up calibration. The value is taken into account by
                             correcting the measurement readings on the spectrum-analyzer either by a
                             transducer factor (TDF) or an relative offset to reference level.

Schematic:




Testing method:              According to ANSI C63.10-2009 for each individual test, see details in each
                             chapter.




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 11 of 31


4.2. Test system set-up for radiated magnetic field measurements below 30 MHz

Specification:              ANSI C63.4-2009 chapter 8.2.1, ANSI C63.10-2009 chapter 6.4

General Description:        Evaluating the radiated field emissions to be done first by an exploratory emissions
                            measurement and a final measurement for most critical frequencies.

                            The loop antenna was placed at 1 m height above ground plane and 3 m measurement
                            distance from set-up for investigations. Because of reduced measurement distance,
                            correction data were applied, as stated in chapter “General Limit - Radiated field strength
                            emissions below 30 MHz“. The tests are performed in the semi anechoic room recognized
                            by the regulatory commissions.

Schematic:




Testing method:             Exploratory, preliminary measurement           Final measurement on critical
                            The EUT and it’s associated accessories are    frequencies
                            placed on a non-conductive position            Based on the exploratory measurements,
                            manipulator (tipping device) of 0.8 m          the most critical frequencies are re-
                            height which is placed on the turntable. By    measured by main-taining the EUT’s worst-
                            rotating the turntable (step 90°, range 0°to   case operation mode, cable position, etc.
                            360°) and the EUT itself either on 3-
                            orthogonal axis (portable equipment) or 2-     First a frequency zoom around the critical
                            orthogonal axis (defined operational           frequency is done to locate the frequency
                            position of EUT), the emission spectrum        more precisely. After this step, for all
                            and it’s characteristics was recorded with     identified critical frequencies, the
                            an EMI-receiver, broadband loop antenna        maximum peak was determined.
                            and software.
                            The loop antenna was moved at least to         Following parameters were varied: the
                            2-perpendicular axes (antenna vector in        turntable angle continuously in the range 0
                            direction of EUT and parallel to EUT) in       to 360 degree, the EUT itself either over 3-
                            order to maximize the emissions. The           orthogonal axis (not defined usage position)
                            results are documented in a diagram.           or 2-orthogonal axis (defined usage
                            Critical frequencies (low margin to limit)     position).
                            are saved within a data reduction table for
                            further investigations. If various operating   On the determined worst-case position, a
                            modes are supported, further investigations    final measurement with necessary
                            are made to find the worst-case of them.       bandwidth and detector according standard
                            Also the interconnection cables and eut in     has been carried out.
                            order to maximize the emissions.

Formula:                    EC = ER + AF + CL + DF - GA                    AF =Antenna factor
                                                                           CL = Cable loss
                            M = LT-EC                                      DF= Distance correction factor
                                                                           EC = Electrical field – corrected value
                                                                           ER = Receiver reading
                                                                           GA= Gain of pre-amplifier (if used)
                                                                           LT = Limit
                                                                           M = Margin
                            All units are dB-units, positive margin means value is below limit.

Distance correction:        Reference for applied correction (extrapolating) factors:
                            IEEC Transaction EMC, Vol. 47, No. 3 , Aug. 2005, Journal Paper “Extrapolating Near-
                            field emissions of low frequency loop transmitters”.


TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 12 of 31




4.3. Test system set-up for radiated spurious emission measurements

Specification:              ANSI C63.4-2009 chapter 8, ANSI C63.10-2009 chapter 6.6

General Description:        Evaluating the field emissions have to be done first by an exploratory emissions
                            measurement and a final measurement for most critical frequencies. The tests are
                            performed in a CISPR 16-4 compliant fully anechoic room (FAR) recognized by the
                            regulatory commissions. The measurement distance was set to 3 meter for frequencies up
                            to 20 GHz and 1 meter above 20 GHz. The horn antenna is used for frequency range 1
                            GHz to 40 GHz. Due to use of a fully anechoic room the measurement antennas are set to
                            fixed antenna height of 1.55 m (no height scan necessary) and the site validation criteria
                            accord. ANSI63.10:2009 is fulfilled. The EUT is aligned within 3 dB beam width of the
                            measurement antenna, on big EUTs several surface measurements are performed.
Schematic:




Testing method:             Exploratory, preliminary measurements                Final measurement on critical frequencies
                            The EUT and it’s associated accessories are          Based on the exploratory measurements, the most
                            placed on a non-conductive position manipulator      critical frequencies are re-measured by main-
                            (tipping device) of 1.55 m height which is placed    taining the EUT’s worst-case operation mode,
                            on the turntable. By rotating the turntable (range   cable position, etc.
                            0° to 360°, step 45°) and the EUT itself either on   First a frequency zoom around the critical
                            3-orthogonal axis (portable equipment) or 2-         frequency is done to locate the frequency more
                            orthogonal axis (defined operational position of     precisely. After this step, for all identified critical
                            EUT) the emission spectrum and it’s                  frequencies, the maximum peak was determined.
                            characteristics was recorded with an EMI-            Following parameters were varied: the turntable
                            receiver, broadband antenna and software.            angle continuously in the range 0 to 360 degree,
                            The measurements are performed in horizontal         the EUT itself either over 3-orthogonal axis (not
                            and vertical polarization of the measurement         defined usage position) or 2-orthogonal axis
                            antennas. The results are documented in a            (defined usage position). The measurement
                            diagram. Critical frequencies (low margin to         antenna height is fixed to 1.55 m.
                            limit) are saved within a table for further          On the determined worst-case position, a final
                            investigations. If various operating modes are       measurement with necessary bandwidth and
                            supported, further investigations are made to find   detector according standard has been carried out.
                            the worst-case of them. Also the interconnection     The readings on the spectrum analyzer are
                            cables and equipment position were varied in         corrected with conversion value between field
                            order to maximize the emissions.                     strength and E(I)RP, so the readings shown are
                                                                                 equivalent to ERP/EIRP values. Critical
                                                                                 measurements near the limit are re-measured
                                                                                 with      a    substitution      method        accord.
                                                                                 ANSI/TIA/EIA 603.

Formula:                    EC = ER + AF + CL + DF - GA (1)                       EC = Electrical field – corrected value
                                                                                  ER = Receiver reading
                            EcE(I)RP = Ec - 95.2 dB|3m                            M = Margin
                                                                                  LT = Limit
                            M = LT - EcE(I)RP                                     AF = Antenna factor
                                                                                  CL = Cable loss
                                                                                  DF = Distance correction factor (if used)
                                                                                  GA = Gain of pre-amplifier (if used)
                                                                                  EcE(I)RP = Electrical field corrected for E(I)RP

                            All units are dB-units, positive margin means value is below limit.



TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 13 of 31




5. Measurements

5.1. RF Parameter – Power Conducted and Radiated - E.I.R.P.
5.1.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
test location       CETECOM Essen (Chapter. 2.2.1)        Please see Chapter. 2.2.2                Please see Chapter. 2.2.3
 test site          441 EMI SAR  487 SAR NSA             347 Radio.lab.                           420 OTA         
 receiver           377 ESCS30      001 ESS              489 ESU 40                                              
 spectr. analys.    584 FSU         120 FSEM             264 FSEK                                                
 antenna            574 BTA-L       133 EMCO3115         302 BBHA9170  289 CBL 6141                   HFH-Z2  477 GPS
 signaling          392 MT8820A  436 CMU                 547 CMU
 otherwise          400 FTC40x15E  401 FTC40x15E         110 USB LWL  482 Filter Matrix          378 RadiSense
 DC power           456 EA 3013A  463 HP3245A            459 EA 2032-50  268 EA- 3050            494 AG6632A  498 NGPE 40
                                            10 dB                Power
otherwise           331 HC 4055     530                  529               - cable OTA20
                                            Attenuator           divider
line voltage        230 V 50 Hz via public mains         060 110 V 60 Hz via PAS 5000



5.1.2. Requirements
                     §2.1046
                     §22.913(a)(2)
 FCC
                     § 24.232(c)
                     § 27.50(d)(4)

                     RSS-132:4.4 + SRSP 503:5.1.3
 IC                  RSS-133:4.1/6.4 + SRSP-510:5.1.2;
                     RSS-139: 6.4+SRSP-513:5.1.2

                             Maximum Power Output of the mobile phone should be determined while measured radiated E(I)RP.

                    Limit FDD Band 5: 7 Watt ERP (38.4 dBm)
 Limit
                    Limit FDD Band 2: 2 Watt EIRP (33.0 dBm)


                    Limit FDD Band 4:   1 Watt EIRP (30.0 dBm)

Remark: PAR (PEAK-AVERAGE-RATIO) ≤ 13 dB



5.1.3 Test condition and measurement test set-up
Climatic conditions                        Temperature: (22±3°C)                         Rel. humidity: (40±20)%
Test system set-up                         Please see chapter “Test system set-up for conducted measurements on antenna port” ANRITSU
                                           The measurements were performed with the integrated power measurement function of the „radio
                                           communication tester CMU200 from Rohde&Schwarz company. In this way spectrum-analyzers
                                           instrument limitations can be avoided or minimized. Instead, CMU manufacturers declared
                                           measurement error can be considered for this measurement.

                                           The attenuation (insertion loss) at the RF Inputs/Outputs of CMU were set according the path loss
Measurement method                         of the test set-up, determined in a step before starting the measurements. A suitable artificial
                                           antenna or RF-connector is provided by the applicant in order to perform the conducted
                                           measurements. Any data provided with the artificial antenna or connector, have been taken in
                                           account in order to correct the measurement data. (typical 0.3dB for attenuation of antenna
                                           connector)

                                           Peak and Average Values have been recorded for each channel and band.
                                           A call was established on highest power transmit conditions in GMSK and RMC99 mode.

                                           UE is set TX mode, highest transmit power conditions, DTX, MPR or other power saving
                                           techniques have been disabled
Mobile phone settings

                                           The measurements were made at the low, middle and high carrier frequencies of each of the
                                           supported operating band. Choosing three TX-carrier frequencies of the mobile phone, should be
                                           sufficient to demonstrate compliance.




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 14 of 31


5.1.8 Test results


GSM/GPRS mode
GMSK-
Modulation
850MHz Band CS Mode 1Slot
                      ARFCN-                                                 PAR
                                        Peak detektor    RMS detektor
                      Frequency                                               Factor
                                           [dBm]           [dBm]
                        [MHz]                                                [dB]
Channel 128              824.2               32,4               32,2         0,2
Channel 192              837.0               32,4               32,3         0,1
Channel 251              848.8               32,3               32,2         0,1

E-GPRS mode
8-PSK
850MHz Band EGPRS (PS)
                   ARFCN-                                                    PAR
                                      Peak  detektor RMS          detektor
                   Frequency                                                  Factor
                                      [dBm]          [dBm]
                   [MHz]                                                     [dB]
Channel 128        824.2              29,6              27,0                 2,6
Channel 192        837                29,7              27,0                 2,7
Channel 251        848.8              29,7              27,1                 2,6

GSM/GPRS mode
GMSK-
Modulation
1900MHz
Band       CS Mode, 1 Slot
                   ARFCN-                                                    PAR
                                     Peak      detektor RMS       detektor
                   Frequency                                                  Factor
                                     [dBm]              [dBm]
                   [MHz]                                                     [dB]
Channel 512        1850.2            28,9               28,8                 0,1
Channel 661        1880.0            29,1               29                   0,1
Channel 810        1909.8            29                 28,8                 0,2


E-GPRS
mode
8-PSK
1900MHz
Band               EGPRS (PS)
                   ARFCN-                                                    PAR
                                     Peak      detektor RMS       detektor
                   Frequency                                                  Factor
                                     [dBm]              [dBm]
                   [MHz]                                                     [dB]
Channel 512        1850.2            28,5               25,6                 2,9
Channel 661        1880.0            28,6               25,8                 2,8
Channel 810        1909.8            28,5               25,7                 2,8

TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 15 of 31




RMC99-FDD5

                      ARFCN-                                             PAR
                                     Peak    detektor RMS     detektor
                      Frequency                                          Factor
                                     [dBm]            [dBm]
                      [MHz]                                              [dB]
Channel 4132          826.4          26,0            23,1                2,9
Channel 4183          836.6          25,9            23,0                2,9
Channel 4233          846.6          25,9            23,0                2,9


HSUPA - FDD 5

                      ARFCN-                                             PAR
                                     Peak    detektor RMS     detektor
                      Frequency                                           Factor
                                     [dBm]            [dBm]
                      [MHz]                                              [dB]
Channel 4132          826.4          26,4            22,5                3,9
Channel 4183          836.6          26,4            22,5                3,9
Channel 4233          846.6          26,4            22,4                4,0

RMC99 - FDD4

                      ARFCN-                                             PAR
                                     Peak    detektor RMS     detektor
                      Frequency                                           Factor
                                     [dBm]            [dBm]
                      [MHz]                                              [dB]
Channel 1312          1712,4         26,0            22,9                3,1
Channel 1450          1740           26,0            22,9                3,1
Channel 1513          1752,6         25,8            22,7                3,1

HSUPA – FDD 4

                      ARFCN-                                             PAR
                                     Peak    detektor RMS     detektor
                      Frequency                                           Factor
                                     [dBm]            [dBm]
                      [MHz]                                              [dB]

Channel 1312          1712,4         26,16           22,4                3,8
Channel 1450          1740           26,05           22,3                3,8
Channel 1513          1752,6         25,76           22,1                3,6

RMC99 - FDD2

                      ARFCN-                                             PAR
                                     Peak    detektor RMS     detektor
                      Frequency                                           Factor
                                     [dBm]            [dBm]
                      [MHz]                                              [dB]
Channel 9262          1852,4         25,7            22,6                3,1
Channel 9400          1880.0         25,8            22,9                2,9
Channel 9538          1907,6         25,6            22,6                3,0



TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 16 of 31


HSUPA - FDD2

                        ARFCN-                                              PAR
                                     Peak       detektor RMS     detektor
                        Frequency                                            Factor
                                     [dBm]               [dBm]
                        [MHz]                                               [dB]
Channel 9262            1852,4       25,7                22,1               3,7
Channel 9400            1880.0       26,0                22,2               3,8
Channel 9538            1907,6       25,8                22,0               3,8



5.1.0.1. Max. calculated ERP 850 band result
                                                           Peak Output
                   Set-up 2 & op. modes 1                 Power [dBm]
                                                                ERP-
                                                                                  Limit       Result
Band          Antenna gain [dBi]            ARFCN no./          Value
                                                          PK
area                                         Frequency          calc.

                                            128/ 824.2
   850                  3.0                              32.4     35.4       38.45 dBm        passed
                                              MHz


5.1.0.1.1. Max. calculated EIRP 1700 band result
                                                           Peak Output
                   Set-up 2 & op. modes 9                 Power [dBm]
                                                                 EIRP-
                                                                                  Limit   Result
Band          Antenna gain [dBi]       U-ARFCN no./              Value
                                                          PK
area                                   Frequency                  calc.

                                               1312/
1700                    3.0                              26.2     29.2       30.00 dBm        passed
                                            1712.4 MHz


5.1.0.1.2. Max. calculated EIRP 1900 band result
                                                           Peak Output
                   Set-up 2 & op. modes 3                 Power [dBm]
                                                                 EIRP-
                                                                                  Limit   Result
Band          Antenna gain [dBi]       ARFCN no./                Value
                                                          PK
area                                   Frequency                  calc.

1900                    3.0            661/ 1880 MHz     29.1     32.1       33.00 dBm        passed




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 17 of 31


5.2. Radiated field strength emissions below 30 MHz

5.2.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
test location      CETECOM Essen (Chapter. 2.2.1)               Please see Chapter. 2.2.2            Please see Chapter. 2.2.3
test site          441 EMI SAR  487 SAR NSA                    347 Radio.lab.                                       
receiver           377 ESCS30      001 ESS                                                                         
spectr. analys.    584 FSU         120 FSEM                    264 FSEK                                            
antenna            574 BTA-L       133 EMCO3115                302 BBHA9170  289 CBL 6141          030 HFH-Z2  477 GPS
signaling          392 MT8820A  436 CMU                        547 CMU
otherwise          400 FTC40x15E  401 FTC40x15E                110 USB LWL  482 Filter Matrix      378 RadiSense
DC power           456 EA 3013A  457 EA 3013A                  459 EA 2032-50  268 EA- 3050        494 AG6632A  498 NGPE 40
line voltage       230 V 50 Hz via public mains                060 120 V 60 Hz via PAS 5000



5.2.2. Requirements
 FCC                   Part 15, Subpart C, §15.205 & §15.209

 IC                    RSS-Gen., Issue 3
 ANSI                  C63.10-2009
 Frequency                       Field strength limit                 Distance
                                                                                    Remarks
 [MHz]                 [μV/m]            [dBμV/m]                     [m]
 0.009 – 0.490         2400/f (kHz)         67.6 – 20Log(f) (kHz)     300           Correction factor used due to measurement distance of 3 m
 0.490 – 1.705         24000/f (kHz)        87.6 – 20Log(f) (kHz)     30            Correction factor used due to measurement distance of 3 m
 1.705 – 30            30                   29.5                      30            Correction factor used due to measurement distance of 3 m




5.2.3.Test condition and measurement test set-up
Signal link to test system (if used):            air link      cable connection        none
EUT-grounding                                    none          with power supply  additional connection
Equipment set up                                 table top                              floor standing
Climatic conditions                             Temperature: (22±3°C)                   Rel. humidity: (40±20)%
                                                 9 – 150 kHz         RBW/VBW = 200 Hz                 Scan step = 80 Hz
                      Scan data                  150 kHz – 30 MHz                RBW/VBW = 9 kHz                 Scan step = 4 kHz
                                                 other:
EMI-Receiver or       Scan-Mode                  6 dB EMI-Receiver Mode  3dB Spectrum analyser Mode
Analyzer Settings     Detector                  Peak (pre-measurement) and Quasi-PK/Average (final if applicable)
                      Mode:                     Repetitive-Scan, max-hold
                      Sweep-Time                Coupled – calibrated display if continuous signal otherwise adapted to EUT’s individual
                                                transmission duty-cycle
General measurement procedures                  Please see chapter “Test system set-up radiated magnetic field measurements below 30 MHz”



5.2.4. Measurement Results

The results are presented below in summary form only. The EUT performed on middle channel. If critical peaks
found (Margin <10 dB) the lowest and highest channels will be performed too.
Table of measurement results:
                                                        Set-        OP-                                         Used
Diagra        Carrier Channel           Frequency
                                                        up          mode     Remark                             detector          Result
m No.                                   range
                                                        no.         no.
              Range         No.                                                                                 P    A      QP
2.01          Middle        192         9 kHz-30                             --                                 K
                                                                                                                    V
                                                                                                                                passed
2.02          Middle        661         9MHz kHz-30                          --                                                passed
2.03          Middle        9400         9MHzkHz-30         1          1     --                                                passed
2.04          Middle        1413          9MHz
                                             kHz-30                          --                                                passed
2.05          Middle        4182           9 kHz-30                          --                                                passed




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 18 of 31


5.2.5. General Limit - Conducted out of Band RF emissions
5.2.6. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
test location      CETECOM Essen (Chapter. 2.2.1)      Please see Chapter. 2.2.2          Please see Chapter. 2.2.3
test site          441 EMI SAR  487 SAR NSA           337 OATS          347 Radio.lab.  443 FAR
receiver           377 ESCS30       001 ESS           489 ESU
spectr. analys.    584 FSU          120 FSEM          264 FSEK
antenna            574 BTA-L        133 EMCO3115      302 BBHA9170  608 HL 562          549 HL025         477 GPS
signaling          017 CMD 65       323 CMD 55        340 CMD 55
signaling          392 MT8820A  436 CMU               547 CMU
power supply       463 HP3245A  457 EA 3013A          459 EA 2032-50  268 EA- 3050      494 AG6632A  498 NGPE 40
otherwise          529 6dB divider  530 10dB Att.     110 USB LWL  482 Filter Matrix  431 Near field
line voltage       via public mains                   060 120 V 60 Hz via PAS 5000 bei Bedarf andere Werte einsetzen



5.2.7. Requirements and limits
                                          Part 2.1053(a), Part2.1057
                                          Part 15 Subpart C, §15.209 @ frequencies defined in §15.205
 FCC                                      Part 22 Subpart H, §22.917(a)(b
                                          Part 24 Subpart E, §24.238(a)(b)
                                          Part 27 Subpart C, §27.53(h)(3)
                                          RSS-132, Issue 2: 4.5.1.1,
 IC                                       RSS-133, Issue 5: 6.5.1(a)(b)
                                          RSS-139, Issue 2: 6.5
                                         Condcuted emissions limits
                   Frequency [MHz]
 Limit                                   Peak [dBm]
                   ≥ 30                                                    -13



5.2.8. Test condition and test set-up
Climatic conditions                     Temperature: (22±3°C)                         Rel. humidity: (40±20)%
Test system set-up                      Please see chapter “Test system set-up for conducted measurements on antenna port”
                                        Ҥ 2.1057 Frequency spectrum to be investigated. (a) In all of the measurements set forth in
                                         § 2.1051 and 2.1053, the spectrum shall be investigated from the lowest radio frequency signal
                                        generated in the equipment, without going below 9 kHz”

                                        The spectrum was scanned from 9 kHz (depend on the equipment, s. §2.1057) to the 10th
                                        harmonic of the highest frequency generated within the equipment. A PEAK detector was used
Measurement method
                                        except measurements near the block-edge where a AVERAGE detector applied.

                                        A suitable artificial antenna or RF-connector is provided by the applicant in order to perform the
                                        conducted measurements. Any data provided with the artificial antenna or connector, have been
                                        taken in account in order to correct the measurement data. (typical 0.3dB for attenuation of
                                        antenna connector)
Spectrum-Analyzer settings              See below tables
                                        A call was established with settings according chapter “Parameter settings on mobile phone and
                                        base station CMU200”

                                        UE Power should be set to maximum, continuous transmission. DTX or other power saving
Mobile phone settings                   techniques have been disabled

                                        The measurements were made at the low, middle and high carrier frequencies of each of the
                                        supported operating band. Choosing three TX-carrier frequencies of the mobile phone, should be
                                        sufficient to demonstrate compliance.




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 19 of 31



5.5.8.1 Settings for G850/FDDV Mode
                Start      Stop   R-BW            V-BW Sweep
                freq.      freq.                       time    Att.   Detector
                MHz        MHz    MHz             MHz  sec.

Sweep 1
(subrange 1) 0.009          1          0.001      0.01   10    25     MaxH-PK

Sweep 1
(subrange 2) 1              30         0.1        1      5     25     MaxH-PK

Sweep 2
(subrange 1) 30             1000       0.1        1      10    35     MaxH-PK

Sweep 2
(subrange 2) 1000           2500       1          1      15    35     MaxH-PK

Sweep 2
(subrange 3) 2500           9000       1          1      60    35     MaxH-PK
Sweep 3a
(Block-
Edge)              823      824        0.003(GSM) 0.01   30    35     MaxH-PK
                                       0.03 (FDD)
Sweep 3b
(Block-
Edge)              823      824                   0.01   30    35     MaxH-AV
Sweep 4a
(Block-
Edge)              850      851        0.003(GSM) 0.01   30    35     MaxH-PK
                                       0.03 (FDD)
Sweep 4b
(Block-
Edge)              850      851                   0.01   30    35     MaxH-AV




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 20 of 31


5.5.8.2 Settings for PCS1900/FDD II/ FDD IV Mode
                Start      Stop      R-BW      V-BW Sweep
                freq.      freq.                    time       Att.   Detector
                MHz        MHz       MHz       MHz  sec.

Sweep 1
(subrange 1) 0.009          1          0.001      0.01   10    25     MaxH-PK

Sweep 1
(subrange 2) 1              30         0.1        1      5     25     MaxH-PK

Sweep 2
(subrange 1) 30             1000       0.1        1      10    35     MaxH-PK

Sweep 2
(subrange 2) 1000           2500       1          1      15    35     MaxH-PK

Sweep 2
(subrange 3) 2500           19500      1          1      160   35     MaxH-PK
Sweep 3a
(Block-
Edge)              1849     1850                  0.01   30    35     MaxH-PK
Sweep 3b
(Block-
Edge)              1849     1850       0.003(GSM) 0.01   30    35     MaxH-AV
                                       0.03(FDD)
Sweep 4a
(Block-
Edge)              1910     1911                  0.01   30    35     MaxH-PK
Sweep 4b
(Block-
Edge)              1910     1911                  0.01   30    35     MaxH-AV




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 21 of 31


5.2.9. Results (conducted)

The EUT emissions were measured below 30 MHz on middle channel only, due to uncritical results.
If critical peaks found (Margin <20 dB) the lowest and highest channels will be performed, too.

The results are presented below in summary form only. For more information please see each diagram enclosed
in annex diagrams.

5.2.10. GSM/GPRS TCH 850: Op. Mode 1, Set-up 2


Transmitting channels/ frequencies: TX = 128/ 824.2 MHz, 192/ 837 MHz, 251/ 848.8 MHz

Sweep no.          Diagram   Frequency of   Range/        Frequency of            Result        Limit   Verdict
                   numbers   emission       ARFCN         worst-peak level

                             [MHz]                        [GHz]                   [dBm]         [dBm]
 Sweep 1           36.00     0.009 to 30    Middle/192    --                      <-52.00               Passed
 Sweep 2           36.01     30 to 9000     Low/128       --                      < -26.00              Passed
                                                                                                -13
 Sweep 2           36.02     30 to 9000     Middle/192    --                      < -26.00              Passed
 Sweep 2           36.03     30 to 9000     High/251      --                      < -26.00              Passed
Remark: --

5.2.11. GSM/GPRS TCH 1900: Op. Mode 3, Set-up 2


Transmitting channels/ frequencies: TX = 512/ 1850.2 MHz, 661/ 1880 MHz, 810/ 1909.8 MHz

Sweep no.          Diagram   Frequency of   Range/        Frequency of            Result        Limit   Verdict
                   numbers   emission       ARFCN         worst-peak level

                             [MHz]                        [GHz]                   [dBm]         [dBm]
 Sweep 1           36.07     0.009 to 30    Middle/661    --                      <-51.00               Passed
 Sweep 2           36.08     30 to 19500    Low/512       --                      < -27.00              Passed
                                                                                                -13
 Sweep 2           36.09     30 to 19500    Middle/661    --                      < -27.00              Passed
 Sweep 2           36.10     30 to 19500    High/810      --                      < -27.00              Passed
Remark: --


5.2.12. FDD II : Op. Mode 5, Set-up 2


Transmitting channels/ frequencies: TX = 9262/ 1852.4 MHz, 9400/ 1880 MHz, 9538/ 1907.6 MHz

Sweep no.          Diagram   Frequency of   Range/        Frequency of            Result        Limit   Verdict
                   numbers   emission       U-ARFCN       worst-peak level

                             [MHz]                        [GHz]                   [dBm]         [dBm]
Sweep 1            36.14     0.009 to 30    Middle/9400   --                      <-51.00               Passed
Sweep 2            36.15     30 to 19500    Low/9262      --                      < -29.00              Passed
                                                                                                -13
Sweep 2            36.16     30 to 19500    Middle/9400   --                      < -30.00              Passed
Sweep 2            36.17     30 to 19500    High/9538     --                      < -29.00              Passed




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 22 of 31



5.2.13. FDD IV TCH : Op. Mode 6, Set-up 2


Transmitting channels/ frequencies: TX = 1312/ 1712.4 MHz, 1413/ 1732.6 MHz, 1513/ 1752.6 MHz

Sweep no.          Diagram   Frequency of   Range/        Frequency of       Result     Limit   Verdict
                   numbers   emission       U-ARFCN       worst-peak level

                             [MHz]                        [GHz]              [dBm]      [dBm]
Sweep 1            36.18     0.009 to 30    Middle/1413   --                 <-51.00            Passed
Sweep 2            36.19     30 to 18000    Low/1312      --                 < -29.00           Passed
                                                                                        -13
Sweep 2            36.20     30 to 18000    Middle/1413   --                 < -29.00           Passed
Sweep 2            36.21     30 to 18000    High/1513     --                 < -30.00           Passed


5.2.14. FDD V TCH : Op. Mode 7, Set-up 2


Transmitting channels/ frequencies: TX = 4132/ 826.4 MHz, 4182/ 836.4 MHz, 4233/ 846.6 MHz

Sweep no.          Diagram   Frequency of   Range/        Frequency of       Result     Limit   Verdict
                   numbers   emission       U-ARFCN       worst-peak level

                             [MHz]                        [GHz]              [dBm]      [dBm]
Sweep 1            36.22     0.009 to 30    Middle/4182   --                 <-51.00            Passed
Sweep 2            36.23     30 to 9000     Low/4132      --                 < -29.00           Passed
                                                                                        -13
Sweep 2            36.24     30 to 9000     Middle/4182   --                 < -29.00           Passed
Sweep 2            36.25     30 to 9000     High/4233     --                 < -30.00           Passed




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 23 of 31


5.3. RF Paramater - Radiated out of Band RF emissions
5.3.1. Test location and equipment (for reference numbers please see chapter 'List of test equipment')
test location      CETECOM Essen (Chapter. 2.2.1)             Please see Chapter. 2.2.2                 Please see Chapter. 2.2.3
test site          441 EMI SAR  487 SAR NSA                  443 FAR           347 Radio.lab.
receiver           377 ESCS30       001 ESS                  489 ESU
spectr. analys.    584 FSU          120 FSEM                 264 FSEK
antenna            608 HL 562       549 HL 025               302 BBHA9170  289 CBL 6141               030 HL-025         477 GPS
signaling          017 CMD 65       323 CMD 55               340 CMD 55
signaling          392 MT8820A  546 CMU                      547 CMU
power supply       463 HP3245A  457 EA 3013A                 459 EA 2032-50  268 EA- 3050             494 AG6632A  498 NGPE 40
otherwise          529 6dB divider  530 10dB Att.            110 USB LWL  482 Filter Matrix           431 Near field
line voltage       230 V 50 Hz via public mains              060 120 V 60 Hz via PAS 5000



5.3.2. Requirements/Limits
                                                 Part 2.1053(a), Part2.1057(a)(1)
                                                 Part 15 Subpart C, §15.209 @ frequencies defined in §15.205
 FCC                                             Part 22 Subpart H, §22.917(a)(b
                                                 Part 24 Subpart E, §24.238(a)(b)
                                                 Part 27 Subpart E, §27.53(h)(3)
                                                 RSS-132, Issue 2: 4.5.1.1,
 IC                                              RSS-133, Issue 5: 6.5.1(a)(b)
                                                 RSS-139, Issue 2: 6.5
                                                                             Radiated emissions limits, 3 meters
                       Frequency [MHz]
 Limit                                                                                  Peak [dBm]
                                 ≥ 30                                                     -13

5.3.3. Test condition and measurement test set-up
link to test system (if used):                  air link        cable connection
EUT-grounding                                   none            with power supply           additional connection
Equipment set up                                table top                                    floor standing
Climatic conditions                            Temperature: (22±3°C)                         Rel. humidity: (40±20)%
Test system set-up                             Please see chapter “Test system set-up for spurious emission measurement”
                                               The spectrum was scanned from 9 kHz to the 10th harmonic of the highest frequency generated
Measurement method                             within the equipment. A PEAK detector was used except measurements near the block-edge
                                               where a AVERAGE detector applied. Below described settings for spectrum-analyzer applies.
                                               A call was established with settings according chapter “Parameter settings on mobile phone and
                                               base station CMU200”

                                               The UE and used accessories (if any used) were set to work according their intended
Mobile phone settings                          use/specification stated as by the applicant

                                               The measurements were made at the low, middle and high carrier frequencies of each of the
                                               supported operating band. Choosing three TX-carrier frequencies of the mobile phone, should be
                                               sufficient to demonstrate compliance.



5.3.3.1. Spectrum-Analyzer settings for GSM/GPRS/E-GPRS 850 Mode/ FDD V Mode
                        Start      Stop      R-BW      V-BW      Sweep
                                                                          Att.
                        freq.      freq.                         time                                                      Detector
                                                                          [dB]
                        MHz        MHz       MHz       MHz       sec.
Sweep 1 (subrange 1)                    30       1000           1                 1              10                10      MaxH-PK
Sweep 2 (subrange 2)                    1000     2800           1                 1              15                10      MaxH-PK
Sweep 3 (subrange 3)                    2800     9000           1                 1              60                10      MaxH-PK


Sweep 4a (Block-Edge) 823                        824            0.003(GSM) 0.01                  30                10      MaxH-PK
Sweep 4b (Block-Edge) 849                        850            0.03 (FDD) 0.1                   30                10      MaxH-PK




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 24 of 31


5.3.3.2. Spectrum-analyzer settings for GSM/GPRS/E-GPRS 1900 Mode/ FDD II / FDD IV Mode
                        Start       Stop     R-BW       V-BW     Sweep
                        freq.       freq.                        time        Att.   Detector
                        MHz         MHz      MHz        MHz      sec.
 Sweep 1 (subrange 1)   30          1000     1          1        10          10     MaxH-PK
 Sweep 2 (subrange 2)   1000        2800     1          1        15          10     MaxH-PK
 Sweep 3 (subrange 3)   2800        20000    1          1        160         10     MaxH-PK
 Sweep 4a (Band-Edge) 1849          1850     0.003(GSM) 0.01     30          10     MaxH-PK
 Sweep 4b (Band-Edge) 1910          1911     0.03 (FDD) 0.1      30          10     MaxH-AV




5.3.4. Results spurious emissions radiated

GSM and FDD modes selected which has the highest ERP and EIRP values and critical measured level
(Margin < 6dB) will be notified, only.

The results are presented below in summary form only. For more information please see each diagram enclosed
in annex diagrams.


5.3.4.1. G850
                                                                                                    Result
                   Carrier                 Set-          OP-
Diagram                          Frequency                                          Used detector
                   Channel                 up            mode   Remark
no.                              range
                                           no.            no.
                                                                                    PK    AV QP

8.01                      Low                             1                                      passed

                                                                Uplink carrier of            
8.02                  Middle     30 –            1        1                                         passed
                                                                GSM band on
                                 9000 MHz
                                                                diagrams
8.03                      High                            1                                      passed



5.3.4.2. PCS 1900
                                                                                                    Result
                   Carrier                 Set-      OP-
Diagram                          Frequency                                          Used detector
                   Channel                 up        mode       Remark
no.                              range
                                           no.       no.
                                                                                    PK    AV QP

8.04               Low                               3                                           passed
                                 30 –                           Uplink carrier of
8.05               Middle                    1       3                                           passed
                                 18000                          GSM band on
                                 MHz                            diagrams
8.06               High                              3                                           passed




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 25 of 31


5.3.4.3. FDD II
                                                                                            Result
                   Carrier                Set-   OP-
Diagram                         Frequency                                   Used detector
                   Channel                up     mode   Remark
no.                             range
                                          no.    no.                        PK    AV QP

8.20               Low                           5                                       passed
                                30 –                    Uplink carrier of
8.21               Middle                   1    5                                       passed
                                18000                   FDD band on
                                MHz                     diagrams
8.22               High                          5                                       passed




5.3.4.4. FDD IV
                                                                                            Result
                   Carrier                Set-   OP-
Diagram                         Frequency                                   Used detector
                   Channel                up     mode   Remark
no.                             range
                                          no.    no.
                                                                            PK    AV QP

8.23               Low                           6                                       passed
                                30 –                    Uplink carrier of
8.24               Middle                   1    6                                       passed
                                17000                   FDD band on
                                MHz                     diagrams
8.25               High                          6                                       passed




5.3.4.5. FDD V
                                                                                            Result
                   Carrier                Set-   OP-
Diagram                         Frequency                                   Used detector
                   Channel                up     mode   Remark
no.                             range
                                          no.    no.                        PK    AV QP

8.26               Low                           7                                       passed
                                30 –                    Uplink carrier of
8.27               Middle                   1    7                                       passed
                                9000                    FDD band on
                                MHz                     diagrams
8.28               High                          7                                       passed




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 26 of 31



5.4. Measurement uncertainties

The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate
coverage factor k, such that a confidence level of approximately 95% is achieved.
For uncertainty determination, each component used in the concrete measurement set-up was taken in account
and it’s contribution to the overall uncertainty according it’s statistical distribution calculated.

Following table shows expectable uncertainties for each measurement type performed.

                                                                   Calculated uncertainty based
           RF-Measurement                   Frequency range                                                   Remarks:
                                                                   on a confidence level of 95%
Power Output conducted                    9 kHz .. 20 GHz         1.0 dB                               --
Power Output radiated                     30 MHz .. 4 GHz         3.17 dB                              Substitution method
Conducted emissions on antenna ports      9 kHz .. 20 GHz         1.0 dB                               --
                                          150 kHz .. 30 MHz       5.0 dB                               Magnetic field
Radiated emissions enclosure              30 MHz .. 1 GHz         4.2 dB                               E-Field
                                          1 GHz .. 20 GHz         3.17 dB                              Substitution method
                                          9 kHz .. 4 GHz          0.1272 ppm (Delta Marker )           Frequency error
Occupied bandwidth
                                                                  1.0 dB                               Power
                                          9 kHz .. 4 GHz          0.1272 ppm (Delta Marker)            Frequency error
Emission bandwidth
                                                                  1.0 dB                               Power
Frequency stability                       9 kHz .. 20 GHz         0.0636 ppm                           --
Conducted emissions                       9 kHz .. 150 kHz        4.0 dB                               --
on AC-mains port (UCISPR)                 150 kHz .. 30 MHz       3.6 dB

Table: measurement uncertainties, valid for conducted/radiated measurements




6. Abbreviations used in this report

The abbreviations
ANSI               American National Standards Institute
AV or AVG          Average detector
CAV                Average detector
EIRP               Equivalent isotropically radiated power, determined within a separate measurement
EGPRS              Enhanced General Packet Radio Service
EUT                Equipment Under Test
FCC                Federal Communications Commission, USA
IC                 Industry Canada
n.a.               not applicable
Op-Mode            Operating mode of the equipment
PK                 Peak
RBW                resolution bandwidth
RF                 Radio frequency
RSS                Radio Standards Specification, Dokuments from Industry Canada
Rx                 Receiver
TCH                Traffic channel
Tx                 Transmitter
QP                 Quasi peak detector
VBW                Video bandwidth
ERP                Effective radiated power




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 27 of 31



7. Accreditation details of CETECOM’s laboratories and test sites

Ref.-          Accreditation                          Valid for laboratory area or test site
No.             Certificate                                                                                               Accreditation Body
-                  D-PL-                                                                                           DAkkS, Deutsche
                                    All laboratories and test sites of CETECOM GmbH, Essen
                12047-01-01                                                                                        Akkreditierungsstelle GmbH
337                 Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
                                                                                                                   FCC, Federal Communications
487                 Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                                                   Commission
558     736496      Radiated Measurements above 1 GHz, 3 m (FAR)
                                                                                                                   Laboratory Division, USA
348                 Mains Ports Conducted Interference Measurements
                                                                                                                   (MRA US-EU 0003)
348                 Telecommunication Ports Conducted Interference Measurem.
337    3462D-1      Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
                                                                                                                   IC, Industry Canada
487    3462D-2      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                                                   Certification and Engineering
550    3462D-2      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                                                   Bureau
558    3462D-3      Radiated Measurements above 1 GHz, 3 m (FAR)
337     R-2665      Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
                                                                                                                   VCCI, Voluntary Control
487     R-2666      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                                                   Council for Interference by
550     G-301       Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                                                   Information Technology
348     C-2914      Mains Ports Conducted Interference Measurements
                                                                                                                   Equipment, Japan
348     T-1967      Telecommunication Ports Conducted Interference Measurem.
OATS = Open Area Test Site, SAR = Semi Anechoic Room, FAR = Fully Anechoic Room


8. Instruments and Ancillary
8.1. Used equipment “CTC”
The “Ref.-No” in the left column of the following tables allows the clear identification of the laboratory
equipment.


8.1.1. Test software and firmware of equipment
 Ref.-No.




                           Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


001         EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
012         Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
013         Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
017         Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
053         Audio Analyzer                            UPA3                     860612/022          Firm. V 4.3
119         RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
140         Signal Generator                          SMHU                     831314/006          Firm.= 3.21
261         Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
262         Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
263         Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
264         Spectrum Analyzer                         FSEK 30                  826939/005          Bios=2.1, Analyzer= 3.20
                                                                                                   UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
295         Racal Digital Radio Test Set              6103                     1572
                                                                                                   SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                   R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
298         Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                   all band used
323         Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
331         Climatic Test Chamber -40/+80 Grad        HC 4055                  43146               TSI 1.53
335         CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
340         Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
355         Power Meter                               URV 5                    891310/027          Firm.= 1.31
365         10V Insertion Unit 50 Ohm                 URV5-Z2                  100880              Eprom Data = 31.03.08
366         Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
371         Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
377         EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
378         Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
383         Signal Generator                          SME 03                   842 828 /034        Firm.= 4.61
389         Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                   Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
392         Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                   4.52#002
                                                                                                   R&S Test Firmware Base=5.14, Mess-Software=
436         Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                   GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
441         CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
442         CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                      System CTC-FAR-EMI-
443         CTC-FAR-EMI-RSE                                                    -                   Spuri 7.2.5 or EMC 32 Ver. 8.53
                                                      RSE
444         CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 8.40
460         Univ. Radio Communication Tester          CMU 200                  108901              R&S Test Firmware Base=5.14, GSM=5.14


TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 28 of 31


 Ref.-No.
                          Equipment                             Type               Serial-No.        Version of Firmware or Software during the test


                                                                                                 WCDMA=5.14 (current Testsoftw.,f. all band to be used,
489         EMI Test Receiver                         ESU40                   1000-30            Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
491         ESD Simulator dito                        ESD dito                dito307022         V 2.30
524         Voltage Drop Simulator                    VDS 200                 0196-16            Software Nr: 000037 Version V4.20a01
526         Burst Generator                           EFT 200 A               0496-06            Software Nr. 000034 Version V2.32
527         Micro Pulse Generator                     MPG 200 B               0496-05            Software-Nr. 000030 Version V2.43
528         Load Dump Simulator                       LD 200B                 0496-06            Software-Nr. 000031 Version V2.35a01
                                                                                                 R&S Test Firmware Base=5.14, GSM=5.14
546         Univ. Radio Communication Tester          CMU 200                 106436
                                                                                                 WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                 R&S Test Firmware Base=V5.1403 (current Testsoftw.,
547         Univ. Radio Communication Tester          CMU 200                 835390/014
                                                                                                 f. all band used, GSM = 5.14 WCDMA: = 5.14
584         Spectrum Analyzer                         FSU 8                   100248             2.82_SP3
594         Wideband Radio Communication Tester       CMW500                  101757             Firmware Base=2.0.20.9, LTE=2.0.20.8. CDMA= 2.0.10
                                                                                                 R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
597         Univ. Radio Communication Tester          CMU 200                 100347
                                                                                                 not installed, Mainboard= µP1=V.850
598         Spectrum Analyzer                         FSEM 30 (Reserve)       831259/013         Firmware Bios 3.40 , Analyzer 3.40 Sp 2
620         EMI Test Receiver                         ESU 26                  100362             4.43_SP3
642         Wideband Radio Communication Tester       CMW 500                 126089




8.1.2. Single instruments and test systems
 Ref.-No.




                                                                                                                             calibration
                                                                                                                             Interval of



                                                                                                                                            Remark
                           Equipment                              Type              Serial-No.         Manufacturer                                      Cal
                                                                                                                                                         due

001         EMI Test Receiver                         ESS                     825132/017          Rohde & Schwarz           12 M           -         31.03.2014
005         AC - LISN (50 Ohm/50µH, test site 1)      ESH2-Z5                 861741/005          Rohde & Schwarz           24/12 M        -         31.03.2014
007         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                 892563/002          Rohde & Schwarz           24/12 M        -         31.03.2014
009         Power Meter (EMS-radiated)                NRV                     863056/017          Rohde & Schwarz           24 M           -         31.03.2014
016         Line Impedance Simulating Network         Op. 24-D                B6366               Spitzenberger+Spies       36 M           -         31.03.2014
020         Horn Antenna 18 GHz (Subst 1)             3115                    9107-3699           EMCO                      36/12 M        -         31.03.2014
021         Loop Antenna (H-Field)                    6502                    9206-2770           EMCO                      36 M           -         31.03.2015
030         Loop Antenna (H-field)                    HFH-Z2                  879604/026          Rohde & Schwarz           36 M           -         31.03.2015
033         RF-current probe (100kHz-30MHz)           ESH2-Z1                 879581/18           Rohde & Schwarz           24 M           -         31.03.2014
057         relay-switch-unit (EMS system)            RSU                     494440/002          Rohde & Schwarz           pre-m          1a
060         power amplifier (DC-2kHz)                 PAS 5000                B6363               Spitzenberger+Spies       -              3
                                                      WRCT 1900/2200-5/40-
066         notch filter (WCDMA; FDD1)                                        5                   Wainwright GmbH           12 M           1g        30.06.2014
                                                      10EEK
086         DC - power supply, 0 -10 A                LNG 50-10               -                   Heinzinger Electronic     pre-m          2
087         DC - power supply, 0 -5 A                 EA-3013 S               -                   Elektro Automatik         pre-m          2
090         Helmholtz coil: 2x10 coils in series      -                       -                   RWTÜV                     -              4
091         USB-LWL-Converter                         OLS-1                   007/2006            Ing. Büro Scheiba         -              4
099         passive voltage probe                     ESH2-Z3                 299.7810.52         Rohde & Schwarz           36 M           -         31.03.2015
100         passive voltage probe                     Probe TK 9416           without             Schwarzbeck               36 M           -         31.03.2015
110         USB-LWL-Converter                         OLS-1                   -                   Ing. Büro Scheiba         -              4
119         RT Harmonics Analyzer dig. Flickermeter   B10                     G60547              BOCONSULT                 36 M           -         31.03.2014
134         horn antenna 18 GHz (Subst 2)             3115                    9005-3414           EMCO                      12 M           -         31.03.2014
136         adjustable dipole antenna (Dipole 1)      3121C-DB4               9105-0697           EMCO                      36 M           -         31.03.2015
140         Signal Generator                          SMHU                    831314/006          Rohde & Schwarz           24 M           -         31.03.2014
248         attenuator                                SMA 6dB 2W              -                   Radiall                   pre-m          2
249         attenuator                                SMA 10dB 10W            -                   Radiall                   pre-m          2
252         attenuator                                N 6dB 12W               -                   Radiall                   pre-m          2
256         attenuator                                SMA 3dB 2W              -                   Radiall                   pre-m          2
257         hybrid                                    4031C                   04491               Narda                     pre-m          2
260         hybrid coupler                            4032C                   11342               Narda                     pre-m          2
261         Thermal Power Sensor                      NRV-Z55                 825083/0008         Rohde & Schwarz           24 M           -         31.03.2014
262         Power Meter                               NRV-S                   825770/0010         Rohde & Schwarz           24 M           -         31.03.2014
263         Signal Generator                          SMP 04                  826190/0007         Rohde & Schwarz           36 M           -         31.03.2014
264         Spectrum Analyzer                         FSEK 30                 826939/005          Rohde & Schwarz           12 M           -         31.03.2014
265         peak power sensor                         NRV-Z33, Model 04       840414/009          Rohde & Schwarz           24 M           -         31.03.2014
266         peak power sensor                         NRV-Z31, Model 04       843383/016          Rohde & Schwarz           24 M           -         31.03.2014
267         notch filter GSM 850                      WRCA 800/960-6EEK       9                   Wainwright GmbH           pre-m          2
270         termination                               1418 N                  BB6935              Weinschel                 pre-m          2
271         termination                               1418 N                  BE6384              Weinschel                 pre-m          2
272         attenuator (20 dB) 50 W                   Model 47                BF6239              Weinschel                 pre-m          2
273         attenuator (10 dB) 100 W                  Model 48                BF9229              Weinschel                 pre-m          2
274         attenuator (10 dB) 50 W                   Model 47 (10 dB) 50 W   BG0321              Weinschel                 pre-m          2
275         DC-Block                                  Model 7003 (N)          C5129               Weinschel                 pre-m          2
276         DC-Block                                  Model 7006 (SMA)        C7061               Weinschel                 pre-m          2
279         power divider                             1515 (SMA)              LH855               Weinschel                 pre-m          2
287         pre-amplifier 25MHz - 4GHz                AMF-2D-100M4G-35-10P    379418              Miteq                     12 M           1c        30.06.2014
291         high pass filter GSM 850/900              WHJ 2200-4EE            14                  Wainwright GmbH           12 M           1c        30.06.2014



TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 29 of 31


 Ref.-No.




                                                                                                                             calibration
                                                                                                                             Interval of



                                                                                                                                               Remark
                             Equipment                         Type                    Serial-No.           Manufacturer                                    Cal
                                                                                                                                                            due

298         Univ. Radio Communication Tester          CMU 200                  832221/091           Rohde & Schwarz          pre-m         3
300         AC LISN (50 Ohm/50µH, 1-phase)            ESH3-Z5                  892 239/020          Rohde & Schwarz          24/12 M       -            31.03.2014
301         attenuator (20 dB) 50W, 18GHz             47-20-33                 AW0272               Lucas Weinschel          pre-m         2
302         horn antenna 40 GHz (Meas 1)              BBHA9170                 155                  Schwarzbeck              36 M          -            31.03.2014
303         horn antenna 40 GHz (Subst 1)             BBHA9170                 156                  Schwarzbeck              36 M          -            31.03.2014
331         Climatic Test Chamber -40/+80 Grad        HC 4055                  43146                Heraeus Vötsch           24 M          -            30.11.2012
341         Digital Multimeter                        Fluke 112                81650455             Fluke                    24 M          -            31.03.2014
342         Digital Multimeter                        Voltcraft M-4660A        IB 255466            Voltcraft                24 M          -            31.03.2014
347         laboratory site                           radio lab.               -                    -                        -             5
348         laboratory site                           EMI conducted            -                    -                        -             5
354         DC - Power Supply 40A                     NGPE 40/40               448                  Rohde & Schwarz          pre-m         2
355         Power Meter                               URV 5                    891310/027           Rohde & Schwarz          24 M          -            31.03.2014
356         power sensor                              NRV-Z1                   882322/014           Rohde & Schwarz          24 M          -            31.03.2014
357         power sensor                              NRV-Z1                   861761/002           Rohde & Schwarz          24 M          -            31.03.2014
371         Bluetooth Tester                          CBT32                    100153               R&S                      12 M          -            31.03.2014
373         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                  100535               Rohde & Schwarz          24/12 M       -            31.03.2014
376         Horn Antenna 6 GHz                        BBHA9120 E               BBHA 9120 E 179      Schwarzbeck              12 M          -            31.03.2014
377         EMI Test Receiver                         ESCS 30                  100160               Rohde & Schwarz          12 M          -            31.03.2014
389         Digital Multimeter                        Keithley 2000            0583926              Keithley                 24 M          -            31.03.2014
392         Radio Communication Tester                MT8820A                  6K00000788           Anritsu                  12 M          -            31.03.2014
431         Model 7405                                Near-Field Probe Set     9305-2457            EMCO                     -             4
436         Univ. Radio Communication Tester          CMU 200                  103083               Rohde & Schwarz          12 M          -            31.03.2014
                                                      System EMI field (SAR)
441         CTC-SAR-EMI Cable Loss                                             -                    CETECOM                  12 M          5            31.10.2014
                                                      Cable
                                                      System CTC-FAR-EMI-                           ETS-Lindgren /
443         CTC-FAR-EMI-RSE                                                    -                                             12 M          5            30.06.2014
                                                      RSE                                           CETECOM
                                                      WRCT 1850.0/2170.0-                           Wainwright Instruments
448         notch filter WCDMA_FDD II                                          5                                             12 M          1c           30.06.2014
                                                      5/40-                                         GmbH
                                                      WRCT 824.0/894.0-5/40-
449         notch filter WCDMA FDD V                                           1                    Wainwright               12 M          1c           30.06.2014
                                                      8SSK
454         Oscilloscope                              HM 205-3                 9210 P 29661         Hameg                    -             4
456         DC-Power supply 0-5 A                     EA 3013 S                207810               Elektro Automatik        pre-m         2
459         DC -Power supply 0-5 A , 0-32 V           EA-PS 2032-50            910722               Elektro Automatik        pre-m         2
460         Univ. Radio Communication Tester          CMU 200                  108901               Rohde & Schwarz          12 M          -            31.03.2014
463         Universal source                          HP3245A                  2831A03472           Agilent                  -             4
466         Digital Multimeter                        Fluke 112                89210157             Fluke USA                24 M          -            31.03.2014
467         Digital Multimeter                        Fluke 112                89680306             Fluke USA                24 M          -            31.03.2014
468         Digital Multimeter                        Fluke 112                90090455             Fluke USA                24 M          -            31.03.2014
477         ReRadiating GPS-System                    AS-47                    -                    Automotive Cons. Fink    -             3
480         power meter (Fula)                        NRVS                     838392/031           Rohde & Schwarz          24 M          -            31.03.2014
482         filter matrix                             Filter matrix SAR 1      -                    CETECOM (Brl)            -             1d
                                                      AMF-5D-02501800-25-
484         pre-amplifier 2,5 - 18 GHz                                         1244554              Miteq                    12 M          -            30.06.2014
                                                      10P
                                                      System EMI field (SAR)                        ETS Lindgren /
487         System CTC NSA-Verification SAR-EMI                                -                                             24 M          -            30.09.2014
                                                      NSA                                           CETECOM
489         EMI Test Receiver                         ESU40                    1000-30              Rohde & Schwarz          12 M          -            31.03.2014
                                                      WRCG 1709/1786-
502         band reject filter                                                 SN 9                 Wainwright               pre-m         2
                                                      1699/1796-
503         band reject filter                        WRCG 824/849-814/859-    SN 5                 Wainwright               pre-m         2
                                                      WRCA 800/960-02/40-
512         notch filter GSM 850                                               SN 24                Wainwrght                12 M          1c           30.06.2014
                                                      6EEK
517         relais switch matrix                      HF Relais Box Keithley   SE 04                Keithley                 pre-m         2
523         Digital Multimeter                        L4411A                   MY46000154           Agilent                  24 M          -            31.03.2014
529         6 dB Broadband resistive power divider    Model 1515               LH 855               Weinschel                pre-m         2
530         10 dB Broadband resistive power divider   R 416110000              LOT 9828             -                        pre-m         2
546         Univ. Radio Communication Tester          CMU 200                  106436               R&S                      12 M          -            31.03.2014
547         Univ. Radio Communication Tester          CMU 200                  835390/014           Rohde & Schwarz          12 M          -            31.03.2014
548         Digital-Barometer                         GBP 2300                 without              Greisinger GmbH          36 M          -            30.06.2015
549         Log.Per-Antenna                           HL025                    1000060              Rohde & Schwarz          36/12 M       -            31.03.2015
552         high pass filter 2,8-18GHz                WHKX 2.8/18G-10SS        4                    Wainwright               12 M          1c           30.06.2014
                                                      System CTC FAR S-
558         System CTC FAR S-VSWR                                              -                    CTC                      24 M          -            31.07.2014
                                                      VSWR
574         Biconilog Hybrid Antenna                  BTA-L                    980026L              Frankonia                36/12 M       -            30.03.2014
584         Spectrum Analyzer                         FSU 8                    100248               Rohde & Schwarz          12 M          -            31.03.2014
594         Wideband Radio Communication Tester       CMW500                   101757               Rohde & Schwarz          24 M          -            31.03.2014
597         Univ. Radio Communication Tester          CMU 200                  100347               Rohde & Schwarz          12 M          -            31.03.2014
598         Spectrum Analyzer                         FSEM 30 (Reserve)        831259/013           Rohde & Schwarz          24 M          -            13.01.2014
600         power meter                               NRVD (Reserve)           834501/018           Rohde & Schwarz          24 M          -            31.03.2014
601         medium-sensitivity diode sensor           NRV-Z5 (Reserve)         8435323/003          Rohde & Schwarz          24 M          -            12.01.2014
602         peak power sensor                         NRV-Z32 (Reserve)        835080               Rohde & Schwarz          24 M          -            12.01.2014
608         UltraLog-Antenna                          HL 562                   830547/009           Rohde & Schwarz          36/12 M       -            31.03.2014
611         DC power supply                           E3632A                   KR 75305854          Agilent                  pre-m         2
612         DC power supply                           E3632A                   MY 40001321          Agilent                  pre-m         2
613         Attenuator                                R416120000 20dB 10W      Lot. 9828            Radiall                  pre-m         2
616         Digitalmultimeter                         Fluke 177                88900339             Fluke                    24 M          -            31.03.2014
617         Power Splitter/Combiner                   ZFSC-2-2-S+              S F987001108         Mini Circuits            -             2



TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 30 of 31


 Ref.-No.




                                                                                                                             calibration
                                                                                                                             Interval of



                                                                                                                                               Remark
                           Equipment                         Type                    Serial-No.             Manufacturer                                    Cal
                                                                                                                                                            due

618         Power Splitter/Combiner                50PD-634                    600994                  JFW Industries USA    -             2
619         Power Splitter/Combiner                50PD-634                    600995                  JFW Industries, USA   -             3
620         EMI Test Receiver                      ESU 26                      100362                  Rohde-Schwarz         12 M          -            01.01.2014
621         Step Attenuator 0-139 dB               RSP                         100017                  Rohde & Schwarz       pre-m         2
625         Generic Test Load USB                  Generic Test Load USB       -                       CETECOM               -             2
                                                                               201.0999.9302.6.4.1.4
627         data logger                            OPUS 1                                              G. Lufft GmbH         24 M          -            30.05.2014
                                                                               3
634         Spectrum Analyzer                      FSM (HF-Unit)               826188/010              Rohde & Schwarz       pre-m         2
635         DFS Testbox                            DFS Testbox                 2012 V01                CETECOM SHA           -             -
636         Wärmebildkamera                        Ti32                        Ti32-12060213, Tele     Fluke Corporation     24 M          -            31.07.2014
                                                   HDMI cable with Ethernet
637         High Speed HDMI with Ethernet 1m                                   -                       KogiLink              -             2
                                                   1m
638         HDMI Kabel with Ethernet 1,5 m flach   HDMI cable with Ethernet    -                       Reichelt              -             2
640         HDMI cable 2m rund                     HDMI cable 2m rund          -                       Reichelt              -             2
641         HDMI cable with Ethernet               Certified HDMI cable with   -                       PureLink              -             2
642         Wideband Radio Communication Tester    CMW 500                     126089                  Rohde&Schwarz         24 M          -            31.03.2014




TR6-0330-13-3-6a


Test Report 6-0330-13-3-6a, Page 31 of 31


8.1.3. Legend
Note / remarks                      Calibrated during system calibration:
                          1a        System CTC-SAR-EMS (Ref.-No. 442)
                          1b        System-CTC-EMS-Conducted (Ref.-No. 335)
                          1c        System CTC-FAR-EMI-RSE (Ref.-No . 443)
                          1d        System CTC-SAR-EMI (Ref.-No . 441)
                          1e        System CTC-OATS (EMI radiated) (Ref.-No. 337)
                          1f        System CTC-CTIA-OTA (Ref.-No . 420)
                          1g        System CTC-FAR-EMS (Ref.-No . 444)
                          2         Calibration or equipment check immediately before measurement
                          3         Regulatory maintained equipment for functional check or support purpose
                          4         calibration of this equipment
                                    Ancillary equipment   without has no effect
                                                                  calibration   onmechanical
                                                                              e.g. measuring result
                                                                                             equipment or monitoring equipment
                          5         Test System


Interval of calibration   12 M      12 month
                          24 M      24 month
                          36 M      36 month
                          24/12 M   Calibration every 24 months, between this every 12 months internal validation
                          36/12 M   Calibration every 36 months, between this every 12 months internal validation
                          Pre-m     Check before starting the measurement
                          -         Without calibration




TR6-0330-13-3-6a



Document Created: 2013-11-08 15:23:47
Document Modified: 2013-11-08 15:23:47

© 2024 FCC.report