Test Report BLE

FCC ID: XPYEMMYW163

Test Report

Download: PDF
FCCID_3884383

FCC Measurement/Technical Report on

Host-based multiradio module with
Wi-Fi, Bluetooth and NFC

EMMY-W163

in Bluetooth mode


FCC ID: EMMY-W163: XPYEMMYW163
IC: EMMY-W163: 8595A-EMMYW163


Test Report Reference: MDE_UBLOX_1701_FCCb




Test Laboratory:
7layers GmbH
Borsigstrasse 11
40880 Ratingen
Germany

Note:
The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts
without the written approval of the test laboratory.

7layers GmbH                       Geschäftsführer/
Borsigstraße 11                    Managing Directors:                Registergericht/registered:                           a Bureau Veritas
40880 Ratingen, Germany            Frank Spiller                      Düsseldorf HRB 75554                                  Group Company
T +49 (0) 2102 749 0               Bernhard Retka                     USt-Id.-Nr./VAT-No. DE203159652
F +49 (0) 2102 749 350             Alexandre Norré-Oudard             Steuer-Nr./TAX-No. 147/5869/0385                      www.7layers.com


Commerzbank AG     Account No. 303 016 000 Bank Code 300 400 00    IBAN DE81 3004 0000 0303 0160 00 Swift Code COBADEFF


Table of Contents
1     Applied Standards and Test Summary                           3
1.1   Applied Standards                                             3
1.2   FCC-IC Correlation Table                                      4
1.3   Measurement Summary / Signatures                              5

2     Administrative Data                                          6
2.1   Testing Laboratory                                            6
2.2   Project Data                                                  6
2.3   Applicant Data                                                6
2.4   Manufacturer Data                                             7

3     Test object Data                                             8
3.1   General EUT Description                                       8
3.2   EUT Main components                                           9
3.3   Ancillary Equipment                                         10
3.4   Auxiliary Equipment                                         10
3.5   EUT Setups                                                  10
3.6   Operating Modes                                             11
3.7   Product labelling                                           11

4     Test Results                                               12
4.1   Transmitter Spurious Radiated Emissions                     12
4.2   Band Edge Compliance Radiated                               17

5     Test Equipment                                             20

6     Antenna Factors, Cable Loss and Sample Calculations        22
6.1   LISN R&S ESH3-Z5 (150 kHz – 30 MHz)                         22
6.2   Antenna R&S HFH2-Z2 (9 kHz – 30 MHz)                        23
6.3   Antenna R&S HL562 (30 MHz – 1 GHz)                          24
6.4   Antenna R&S HF907 (1 GHz – 18 GHz)                          25
6.5   Antenna EMCO 3160-09 (18 GHz – 26.5 GHz)                    26
6.6   Antenna EMCO 3160-10 (26.5 GHz – 40 GHz)                    27

7     Setup Drawings                                             28

8     Measurement Uncertainties                                  29

9     Photo Report                                               29




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                  Page 2 of 29


1 Applied Standards and Test Summary

1.1   Applied Standards


Type of Authorization
Certification for an Intentional Radiator.

Applicable FCC Rules

Prepared in accordance with the requirements of FCC Rules and Regulations as listed in 47 CFR
Ch.1 Parts 2 and 15 (10-1-13 Edition). The following subparts are applicable to the results in
this test report.


Part 2, Subpart J - Equipment Authorization Procedures, Certification

Part 15, Subpart C – Intentional Radiators

§ 15.201   Equipment authorization requirement

§ 15.207   Conducted limits

§ 15.209   Radiated emission limits; general requirements

§ 15.247   Operation within the bands 902-928 MHz, 2400-2483.5 MHz



Note 1:
The tests were selected and performed with reference to the FCC Public Notice DA 00-705,
released March 30, 2000. Instead of applying ANSI C63.4-1992 which is referenced in the FCC
Public Note, the newer ANSI C63.10-2013 is applied.




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                      Page 3 of 29


Summary Test Results:

The EUT complied with all performed tests as listed in chapter 1.3 Measurement
Summary / Signatures.


1.2   FCC-IC Correlation Table

Correlation of measurement requirements for
FHSS (e.g. Bluetooth®) equipment
from FCC and IC

FHSS equipment

Measurement                   FCC reference            IC reference
Conducted emissions on AC     § 15.207                 RSS-Gen Issue 4: 8.8
Mains
Occupied bandwidth            § 15.247 (a) (1)         RSS-247 Issue 2: 5.1 (b)
Peak conducted output         § 15.247 (b) (1), (4)    RSS-247 Issue 2: 5.4 (b)
power
Transmitter spurious RF       § 15.247 (d)             RSS-Gen Issue 4:
conducted emissions                                    6.13/8.9/8.10;
                                                       RSS-247 Issue 2: 5.5
Transmitter spurious          § 15.247 (d);            RSS-Gen Issue 4: 6.13 /
radiated emissions            § 15.209 (a)             8.9/8.10;
                                                       RSS-247 Issue 2: 5.5
Band edge compliance          § 15.247 (d)             RSS-247 Issue 2: 5.5
Dwell time                    § 15.247 (a) (1) (iii)   RSS-247 Issue 2: 5.1 (d)
Channel separation            § 15.247 (a) (1)         RSS-247 Issue 2: 5.1 (b)
No. of hopping frequencies    § 15.247 (a) (1) (iii)   RSS-247 Issue 2: 5.1 (d)
Hybrid systems (only)         § 15.247 (f);            RSS-247 Issue 2: 5.3
                              § 15.247 (e)
Antenna requirement           § 15.203 / 15.204        RSS-Gen Issue 4: 8.3
Receiver spurious emissions   –                        -




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                    Page 4 of 29


                                                                                  %layers  A Bureau Veritas Group Company




1.3     Measurement Summary / Signatures


47 CFR CHAPTER I FCC PART 15 Subpart C              § 15.247 (d)
§15.247
Transmitter Spurious Radiated Emissions
The measurement was performed according to ANSI C63.10                                  Final Result

OP—Mode                                                                 Setup           FCC             IC
Radio Technology, Operating Frequency, Measurement range
Bluetooth BDR, high, 1 GHz — 26 GHz                                     DE1072001       Passed          Passed
Remark: noise floor                                                     aa01


Bluetooth BDR, low, 1 GHz — 26 GHz                                      DE1072001       Passed          Passed
Remark: noise floor                                                     aa01


Bluetooth BDR, mid, 1 GHz — 26 GHz                                      DE1072001       Passed          Passed
Remark: noise floor                                                     aa01




47 CFR CHAPTER I FCC PART 15 Subpart C             § 15.247 (d)
§15.247
Band Edge Compliance Radiated
The measurement was performed according to ANSI C63.10                                  Final Result

OP—Mode                                                                 Setup           FCC             IC
Radio Technology, Operating Frequency, Band Edge
Bluetooth BDR, high, high                                               DE1015031       Passed          Passed
Remark: —                                                               aa01
Bluetooth EDR 2, high, high                                             DE1015031       Passed          Passed
Remark: —                                                               aa01




Remark:

Reduced test plan as it is a Class II permissive change



                                                                 . 11
                                         7 layers GmbH, Borsigstr                                            x        s
                                                                  y
                                         40880 Ratingen, German


                                                                        es /)
                                                                0                           \
                          M               Phone +49 (0)2102 749

        (responsible for accreditation scope)                    (respqnsible for testing and report)
                Mr. Marco Kullik                                            r./Imad Hjije




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                                          Page 5 of 29


2 Administrative Data

2.1   Testing Laboratory

Company Name:                            7layers GmbH

Address:                                 Borsigstr. 11
                                         40880 Ratingen
                                         Germany

This facility has been fully described in a report submitted to the ISED and accepted under
the registration number: Site# 3699A-1.

The test facility is also accredited by the following accreditation organisation:

Laboratory accreditation no:             DAkkS D-PL-12140-01-00

FCC Designation Number:                  DE0015

FCC Test Firm Registration:              929146

Responsible for accreditation scope:     Dipl.-Ing. Marco Kullik

Report Template Version:                 2017-07-14
Company Name:                            7layers GmbH

Address:                                 Borsigstr. 11
                                         40880 Ratingen
                                         Germany



2.2   Project Data

Responsible for testing and report:      Mr. Imad Hjije

Employees who performed the tests:       documented internally at 7Layers

Date of Report:                          2018-03-21

Testing Period:                          2018-02-15 to 2018-02-16




2.3   Applicant Data

Company Name:                            u-blox AG

Address:                                 Zürcherstrasse 68
                                         8800 Thalwil
                                         Switzerland

Contact Person:                          Mr. Giulio Comar

TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                          Page 6 of 29


2.4   Manufacturer Data

Company Name:                         please see applicant data

Address:



Contact Person:




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                        Page 7 of 29


3 Test object Data

3.1    General EUT Description


Kind of Device            WLAN 2.4 GHz, 5 GHz, BT, NFC, SRD (5.8 GHz) - Single Antenna
product description
Product name              Host-based multiradio module with Wi-Fi, Bluetooth and NFC for
                          “Mercedes-Benz-Link”
Type                      EMMY-W163

Declared EUT data by the supplier

Voltage Type              DC
Voltage Level             normal: 3,3 V DC
                          low: 3,0 V DC
                          high: 3,6 V DC
Tested Modulation Type GFSK, pi/4-DQPSK, 8DPSK
General product           EMMY-W163 is an ultra-compact multi-radio module providing Wi-
description               Fi, Classic Bluetooth, Bluetooth low energy and NFC mode of
                          operation.
                          It is designed for both simultaneous and independent operations
                          of:
                          • Wi-Fi IEEE 802.11ac and a/b/g/n
                          • Dual-mode Bluetooth 4.2
                          • NFC
Specific product          EMMY-W163: Shielded module, single antenna pin for WLAN
description for the EUT   802.11 ac/a/b/g/n and Bluetooth communication
The EUT provides the      - DC power supply
following ports:          - antenna port
                          - signal ports
Tested datarates          BDR, BT GFSK (1-DH1): 1 Mbit/s
                          BDR, BT GFSK (1-DH5): 1 Mbit/s
                          EDR 2, BT pi/4 DQPSK (2-DH1): 2 Mbit/s
                          EDR 3, BT 8-DPSK (3-DH1): 3 Mbit/s




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                      Page 8 of 29


3.2   EUT Main components




Sample Name               Sample Code                 Description
DE1072001aa01             aa01
   Sample Parameter                               Value
Antenna                   JOHANSON 2450AT45A100
Serial No.                D4CA6E50CAC4
HW Version                -
SW Version                15.26.7.p101
Comment                   -




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                          Page 9 of 29


3.3    Ancillary Equipment

For the purposes of this test report, ancillary equipment is defined as equipment which is used
in conjunction with the EUT to provide operational and control features to the EUT. It is
necessary to configure the system in a typical fashion, as a customer would normally use it.
But nevertheless Ancillary Equipment can influence the test results.

Device                     Details                                      Description
                           (Manufacturer, Type Model, OUT
                           Code)
target platform            lesswire GmbH, MB Link, -, -                 telematics unit




3.4    Auxiliary Equipment

For the purposes of this test report, auxiliary equipment is defined as equipment which is used
temporarily to enable operational and control features especially used for the tests of the EUT
which is not used during normal operation or equipment that is used during the tests in
combination with the EUT but is not subject of this test report. It is necessary to configure the
system in a typical fashion, as a customer would normally use it.
But nevertheless Auxiliary Equipment can influence the test results.

Device                     Details                                      Description
                           (Manufacturer, HW, SW, S/N)
AC/DC power supply         PeakTech, -, -, 081062045                    PeakTech 6005D
(115 V 60 Hz)




3.5    EUT Setups

This chapter describes the combination of EUTs and equipment used for testing. The rationale
for selecting the EUTs, ancillary and auxiliary equipment and interconnecting cables, is to test
a representative configuration meeting the requirements of the referenced standards.

      Setup         Combination of EUTs                 Description and Rationale

                      evaluation board,      Setup for radiated measurement
DE1072001aa01
                     AC/DC power supply




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                          Page 10 of 29


3.6   Operating Modes
This chapter describes the operating modes of the EUTs used for testing.

                                  2.4 GHz ISM
                                  2400 - 2483.5 MHz
 BT Test Channels:                 low    mid    high
 Channel:                           0      39     78
 Frequency [MHz]                  2402    2441   2480

Bluetooth Power Class 1



3.7   Product labelling


       3.7.1FCC ID label
Please refer to the documentation of the applicant.


       3.7.2Location of the label on the EUT
Please refer to the documentation of the applicant.




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                 Page 11 of 29


4 Test Results


4.1   Transmitter Spurious Radiated Emissions

Standard      FCC Part 15 Subpart C

The test was performed according to:
ANSI C63.10

       4.1.1Test Description


The test set-up was made in accordance to the general provisions of ANSI C63.10 in a typical
installation configuration. The Equipment Under Test (EUT) was set up on a non-conductive
table 1.0 x 2.0 m² in the semi-anechoic chamber. The influence of the EUT support table that
is used between 30–1000 MHz was evaluated.
The measurement procedure is implemented into the EMI test software EMC32 from R&S.
Exploratory tests are performed at 3 orthogonal axes to determine the worst-case orientation
of a body-worn or handheld EUT. The final test on all kind of EUTs is also performed at 3 axes.
A pre-check is performed while the EUT is powered from a DC power source.

1. Measurement up to 30 MHz
The Loop antenna HFH2-Z2 is used.

Step 1: pre measurement
       •Anechoic chamber
       •Antenna distance: 3 m
       •Detector: Peak-Maxhold
       •Frequency range: 0.009 - 0.15 MHz and 0.15 – 30 MHz
       •Frequency steps: 0.05 kHz and 2.25 kHz
       •IF–Bandwidth: 0.2 kHz and 9 kHz
       •Measuring time / Frequency step: 100 ms (FFT-based)
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.

Step 2: final measurement
For the relevant emissions determined in step 1, an additional measurement with the following
settings will be performed. Intention of this step is to find the maximum emission level.
       •Open area test side
       •Antenna distance: according to the Standard
       •Detector: Quasi-Peak
       •Frequency range: 0.009 – 30 MHz
       •Frequency steps: measurement at frequencies detected in step 1
       •IF–Bandwidth: 0.2 - 10 kHz
       •Measuring time / Frequency step: 1 s


2. Measurement above 30 MHz and up to 1 GHz

Step 1: Preliminary scan
This is a preliminary test to identify the highest amplitudes relative to the limit.
Settings for step 1:

TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                             Page 12 of 29


- Antenna distance: 3 m
- Detector: Peak-Maxhold / Quasipeak (FFT-based)
- Frequency range: 30 – 1000 MHz
- Frequency steps: 30 kHz
- IF–Bandwidth: 120 kHz
- Measuring time / Frequency step: 100 ms
- Turntable angle range: –180° to 90°
- Turntable step size: 90°
- Height variation range: 1 – 3 m
- Height variation step size: 2 m
- Polarisation: Horizontal + Vertical
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.

Step 2: Adjustment measurement
In this step the accuracy of the turntable azimuth and antenna height will be improved. This is
necessary to find out the maximum value of every frequency.
For each frequency, which was determined the turntable azimuth and antenna height will be
adjusted. The turntable azimuth will slowly vary by ± 45° around this value. During this action,
the value of emission is continuously measured. The turntable azimuth at the highest emission
will be recorded and adjusted. In this position, the antenna height will also slowly vary by ±
100 cm around the antenna height determined. During this action, the value of emission is
also continuously measured. The antenna height of the highest emission will also be recorded
and adjusted.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: ± 45 ° around the determined value
- Height variation range: ± 100 cm around the determined value
- Antenna Polarisation: max. value determined in step 1

Step 3: Final measurement with QP detector
With the settings determined in step 3, the final measurement will be performed:
EMI receiver settings for step 4:
- Detector: Quasi-Peak (< 1 GHz)
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 1 s

After the measurement a plot will be generated which contains a diagram with the results of
the preliminary scan and a chart with the frequencies and values of the results of the final
measurement.

3. Measurement above 1 GHz
The following modifications apply to the measurement procedure for the frequency range
above 1 GHz:
Step 1:
The Equipment Under Test (EUT) was set up on a non-conductive support (tilt device) at 1.5 m
height in the fully-anechoic chamber.
All steps were performed with one height (1.5 m) of the receiving antenna only.
The EUT is turned during the preliminary measurement across the elevation axis, with a step
size of 90 °.
The turn table step size (azimuth angle) for the preliminary measurement is 45 °.
Step 2:

TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                        Page 13 of 29


Due to the fact, that in this frequency range the test is performed in a fully anechoic room, the
height scan of the receiving antenna instep 2 is omitted. Instead of this, a maximum search
with a step size ± 45° for the elevation axis is performed.
The turn table azimuth will slowly vary by ± 22.5°.
The elevation angle will slowly vary by ± 45°
EMI receiver settings (for all steps):
- Detector: Peak, Average
- IF Bandwidth = 1 MHz
Step 3:
Spectrum analyser settings for step 3:
- Detector: Peak / Average
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 1 MHz
- Measuring time: 1 s

        4.1.2Test Requirements / Limits


FCC Part 15, Subpart C, §15.247 (d)
... In addition, radiated emissions which fall in the restricted bands, as defined in Section
15.205(a), must also comply with the radiated emission limits specified in Section 15.209(a)
(see Section 15.205(c)).

FCC Part 15, Subpart C, §15.209, Radiated Emission Limits

                                      Measurement
Frequency in MHz   Limit (µV/m)                       Limits (dBµV/m)
                                      distance (m)
0.009 – 0.49       2400/F(kHz)@300m   3               (48.5 – 13.8)@300m
0.49 – 1.705       24000/F(kHz)@30m   3               (33.8 – 23.0)@30m
1.705 – 30         30@30m             3               29.5@30m


The measured values are corrected with an inverse linear distance extrapolation factor
(40 dB/decade) according FCC 15.31 (2).


                                      Measurement
Frequency in MHz   Limit (µV/m)                       Limits (dBµV/m)
                                      distance (m)
30 – 88            100@3m             3               40.0@3m
88 – 216           150@3m             3               43.5@3m
216 – 960          200@3m             3               46.0@3m
960 - 26000        500@3m             3               54.0@3m
26000 - 40000      500@3m             1               54.0@3m


The measured values above 26 GHz are corrected with an inverse linear distance extrapolation
factor (20 dB/decade).

§15.35(b) ..., there is also a limit on the radio frequency emissions, as measured using
instrumentation with a peak detector function, corresponding to 20 dB above the maximum
permitted average limit....

Used conversion factor: Limit (dBµV/m) = 20 log (Limit (µV/m)/1µV/m)




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                        Page 14 of 29


        4.1.3Test Protocol


Ambient             21–25 °C
temperature:
Air Pressure:       1002–1020 hPa
Humidity:           38–45 %
BT GFSK (1-DH1)
Ch.    Ch.          Spurious        Spurious             Detec-    RBW        Limit      Margin     Limit
No.    Center       Freq.           Level                tor       [kHz]      [dBµV/m]   to Limit   Type
       Freq.        [MHz]           [dBµV/m]                                             [dB]
       [MHz]
0      2402,0       -               noise                ---       -          -          >9         RB
39     2441,0       -               noise                ---       -          -          >9         RB
78     2480,0       2483.50         50.19                PEAK      1000.000   74.00      23.81      RB
78     2480,0       2483.66         36.61                Average   1000.000   54.00      17.39      RB

BT pi/4 DQPSK (2-
DH1)
Ch.    Ch.        Spurious          Spurious             Detec-    RBW        Limit      Margin     Limit
No.    Center     Freq.             Level                tor       [kHz]      [dBµV/m]   to Limit   Type
       Freq.      [MHz]             [dBµV/m]                                             [dB]
       [MHz]
0      2402,0     -                 noise                ---       -          -          >9         RB
39     2441,0     -                 noise                ---       -          -          >9         RB
78     2480,0     2483.50           49.05                PEAK      1000.000   74.00      24.95      RB
78     2480,0     2483.66           36.63                Average   1000.000   54.00      17.37      RB


Remark: No duty cycle correction used for AV-Detector.




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                                Page 15 of 29


       Level in dBµV/m




      4.1.4Test Equipment used
Radiated Emissions




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb   Page 16 of 29


4.2    Band Edge Compliance Radiated

Standard        FCC Part 15 Subpart C

The test was performed according to:
ANSI C63.10

        4.2.1Test Description


Please see test description for the test case “Spurious Radiated Emissions”

        4.2.2Test Requirements / Limits

For band edges connected to a restricted band, the limits are specified in Section 15.209(a)

FCC Part 15, Subpart C, §15.209, Radiated Emission Limits

                                      Measurement
Frequency in MHz   Limit (µV/m)                      Limits (dBµV/m)
                                      distance (m)
0.009 – 0.49       2400/F(kHz)@300m   3              (48.5 – 13.8)@300m
0.49 – 1.705       24000/F(kHz)@30m   3              (33.8 – 23.0)@30m
1.705 – 30         30@30m             3              29.5@30m


The measured values are corrected with an inverse linear distance extrapolation factor
(40 dB/decade) according FCC 15.31 (2).


                                      Measurement
Frequency in MHz   Limit (µV/m)                      Limits (dBµV/m)
                                      distance (m)
30 – 88            100@3m             3              40.0@3m
88 – 216           150@3m             3              43.5@3m
216 – 960          200@3m             3              46.0@3m
960 - 26000        500@3m             3              54.0@3m
26000 - 40000      500@3m             1              54.0@3m


The measured values above 26 GHz are corrected with an inverse linear distance extrapolation
factor (20 dB/decade).

§15.35(b) ..., there is also a limit on the radio frequency emissions, as measured using
instrumentation with a peak detector function, corresponding to 20 dB above the maximum
permitted average limit....

Used conversion factor: Limit (dBµV/m) = 20 log (Limit (µV/m)/1µV/m)




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                      Page 17 of 29


        4.2.3Test Protocol


Ambient temperature:    21–23 °C
Air Pressure:           980–1002 hPa
Humidity:               39–41 %
BT GFSK (1-DH1)
Ch.     Ch. Center   Band    Spurious            Detec-      RBW         Limit         Margin to        Limit
No.     Freq.        Edge    Level               tor         [kHz]       [dBµV/m]      Limit [dB]       Type
        [MHz]        Freq.   [dBµV/m]
                     [MHz]
78      2480,0       2483.5 50.19                PEAK        1000,0      74,0          23.81            BE
78      2480,0       2483.6 36.61                AV          1000,0      54,0          17.39            BE

BT pi/4 DQPSK (2-DH1)
Ch.    Ch. Center   Band          Spurious       Detec-      RBW         Limit         Margin to        Limit
No.    Freq.        Edge          Level          tor         [kHz]       [dBµV/m]      Limit [dB]       Type
       [MHz]        Freq.         [dBµV/m]
                    [MHz]
78      2480,0          2483.5    49.05          PEAK        1000        74,0          24.95            BE
78      2480,0          2483.6    36.63          AV          1000        54,0          17.37            BE




Remark: Duty cycle = 30,88 %, applied duty cycle correction for AV-Detector: 10,2 dB




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                                     Page 18 of 29


        4.2.4Measurement Plot (showing the highest value, “worst case”)


BT 8-DPSK (2-DH1)
        Level in dBµV/m




Critical_Freqs
  Frequency               MaxPeak      Average       Limit     Margi    Meas.    Bandwidt      Heigh   Pol   Azimut     Elevatio
    (MHz)                 (dBµV/m)    (dBµV/m)     (dBµV/m)      n      Time         h           t              h          n
                                                               (dB)     (ms)       (kHz)       (cm)           (deg)      (deg)
   2483.500000               50.13          ---       74.00     23.87      ---           ---   150.0   H       154.0        93.0
   2483.665000                  ---      39.75        54.00     14.25      ---           ---   150.0   V        -53.0       78.0



Final_Result
  Frequency               MaxPeak     CAverage       Limit     Margi    Meas.    Bandwidt      Heigh   Pol   Azimut     Elevatio
    (MHz)                 (dBµV/m)    (dBµV/m)     (dBµV/m)      n      Time         h           t              h          n
                                                               (dB)     (ms)       (kHz)       (cm)           (deg)      (deg)
   2483.500000               49.05           ---       74.00    24.95   1000.     1000.000     150.0   H       154.0        93.0
   2483.665000                  ---       36.63        54.00    17.37   1000.0    1000.000     150.0   V        -53.0       78.0
                                                                            0



        4.2.5Test Equipment used
Radiated Emissions




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                                                                         Page 19 of 29


5 Test Equipment

      1   Radiated Emissions
          Lab to perform radiated emission tests

Ref.No. Device Name Description              Manufacturer       Serial Number       Last    Calibration
                                                                                Calibration     Due
1.1       NRV-Z1          Sensor Head A    Rohde & Schwarz      827753/005      2017-05        2018-05
1.2       MFS             Rubidium         Datum GmbH           002             2017-10        2018-10
                          Frequency
                          Normal MFS
1.3       Opus10 TPR      ThermoAirpres    Lufft Mess- und   13936              2017-04        2019-04
          (8253.00)       sure             Regeltechnik GmbH
                          Datalogger 13
                          (Environ)
1.4       Anechoic        10.58 x 6.38 x   Frankonia            none            2016-05        2019-05
          Chamber         6.00 m³
1.5       HL 562          Ultralog new     Rohde & Schwarz      830547/003      2015-06        2018-06
                          biconicals
1.6       5HC2700/12750 High Pass          Trilithic            9942012
          -1.5-KK         Filter
1.7       ASP 1.2/1.8-10 Antenna Mast      Maturo GmbH          -
          kg
1.8       Fully Anechoic  8.80m x          Albatross Projects   P26971-647-001- 2015-06        2018-06
          Room            4.60m x                               PRB
                          4.05m (l x w x
                          h)
1.9       Fluke 177       Digital          Fluke Europe B.V.    86670383        2016-02        2018-02
                          Multimeter 03
                          (Multimeter)
1.10      JS4-18002600- Broadband          Miteq                849785
          32-5P           Amplifier 18
                          GHz - 26 GHz
1.11      FSW 43          Spectrum         Rohde & Schwarz      103779          2016-12        2018-12
                          Analyzer
1.12      3160-09         Standard Gain    EMCO Elektronic      00083069
                          / Pyramidal      GmbH
                          Horn Antenna
                          26.5 GHz
1.13      WHKX 7.0/18G- High Pass          Wainwright           09
          8SS             Filter
1.14      4HC1600/12750 High Pass          Trilithic            9942011
          -1.5-KK         Filter
1.15      Chroma 6404     AC Power         Chroma ATE INC.      64040001304
                          Source
1.16      JS4-00102600- Broadband          Miteq                619368
          42-5A           Amplifier 30
                          MHz - 26 GHz
1.17      TT 1.5 WI       Turn Table       Maturo GmbH          -
1.18      HL 562 Ultralog Log.-per.        Rohde & Schwarz      100609          2016-04        2019-04
                          Antenna
1.19      3160-10         Standard Gain    EMCO Elektronic      00086675
                          / Pyramidal      GmbH
                          Horn Antenna
                          40 GHz
1.20      5HC3500/18000 High Pass          Trilithic            200035008
          -1.2-KK         Filter
1.21      HFH2-Z2         Loop Antenna     Rohde & Schwarz      829324/006      2014-11        2017-11

TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                                Page 20 of 29


Ref.No. Device Name Description         Manufacturer      Serial Number       Last    Calibration
                                                                          Calibration     Due
1.22    Opus10 THI      ThermoHygro Lufft Mess- und       12482           2017-03        2019-03
        (8152.00)       Datalogger 12 Regeltechnik GmbH
                        (Environ)
1.23    ESR 7           EMI Receiver / Rohde & Schwarz    101424          2016-11        2018-11
                        Spectrum
                        Analyzer
1.24    JS4-00101800- Broadband        Miteq              896037
        35-5P           Amplifier 30
                        MHz - 18 GHz
1.25    AS 620 P        Antenna mast HD GmbH              620/37
1.26    Tilt device     Antrieb TD1.5- Maturo GmbH        TD1.5-
        Maturo          10kg                              10kg/024/37907
        (Rohacell)                                        09
1.27    ESIB 26         Spectrum       Rohde & Schwarz    830482/004     2015-12         2017-12
                        Analyzer
1.28    PAS 2.5 - 10 kg Antenna Mast Maturo GmbH          -
1.29    AM 4.0          Antenna mast Maturo GmbH          AM4.0/180/1192
                                                          0513
1.30    HF 907          Double-ridged Rohde & Schwarz     102444         2015-05         2018-05
                        horn


The calibration interval is the time interval between “Last Calibration” and “Calibration Due”




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                          Page 21 of 29


6 Antenna Factors, Cable Loss and Sample Calculations
This chapter contains the antenna factors with their corresponding path loss of the used
measurement path for all antennas as well as the insertion loss of the LISN.



6.1   LISN R&S ESH3-Z5 (150 kHz – 30 MHz)
                                                       cable
                                            LISN        loss
                                         insertion   (incl. 10
                                            loss         dB
                                           ESH3-      atten-
Frequency                 Corr.              Z5       uator)
   MHz                     dB                dB          dB
     0,15                   10,1               0,1        10,0
        5                   10,3               0,1        10,2
        7                   10,5               0,2        10,3
       10                   10,5               0,2        10,3
       12                   10,7               0,3        10,4
       14                   10,7               0,3        10,4
       16                   10,8               0,4        10,4
       18                   10,9               0,4        10,5
       20                   10,9               0,4        10,5
       22                   11,1               0,5        10,6
       24                   11,1               0,5        10,6
       26                   11,2               0,5        10,7
       28                   11,2               0,5        10,7
       30                   11,3               0,5        10,8

Sample calculation

ULISN (dB µV) = U (dB µV) + Corr. (dB)
U = Receiver reading
LISN Insertion loss = Voltage Division Factor of LISN
Corr. = sum of single correction factors of used LISN, cables, switch units (if used)
Linear interpolation will be used for frequencies in between the values in the table.




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                              Page 22 of 29


6.2   Antenna R&S HFH2-Z2 (9 kHz – 30 MHz)
                                            cable        cable        cable        cable     distance     dLimit      dused
                                            loss 1       loss 2      loss 3       loss 4       corr.     (meas.      (meas.
                AF                         (inside      (outside    (switch         (to      (-40 dB/   distance    distance
Frequency    HFH-Z2)       Corr.          chamber)     chamber)       unit)     receiver)    decade)     (limit)     (used)
   MHz       dB (1/m)       dB                dB           dB          dB           dB          dB          m          m
    0,009      20,50        -79,6                0,1          0,1         0,1          0,1        -80        300            3
     0,01      20,45        -79,6                0,1          0,1         0,1          0,1        -80        300            3
    0,015      20,37        -79,6                0,1          0,1         0,1          0,1        -80        300            3
     0,02      20,36        -79,6                0,1          0,1         0,1          0,1        -80        300            3
    0,025      20,38        -79,6                0,1          0,1         0,1          0,1        -80        300            3
     0,03      20,32        -79,6                0,1          0,1         0,1          0,1        -80        300            3
     0,05      20,35        -79,6                0,1          0,1         0,1          0,1        -80        300            3
     0,08      20,30        -79,6                0,1          0,1         0,1          0,1        -80        300            3
      0,1      20,20        -79,6                0,1          0,1         0,1          0,1        -80        300            3
      0,2      20,17        -79,6                0,1          0,1         0,1          0,1        -80        300            3
      0,3      20,14        -79,6                0,1          0,1         0,1          0,1        -80        300            3
     0,49      20,12        -79,6                0,1          0,1         0,1          0,1        -80        300            3
 0,490001      20,12        -39,6                0,1          0,1         0,1          0,1        -40          30           3
      0,5      20,11        -39,6                0,1          0,1         0,1          0,1        -40          30           3
      0,8      20,10        -39,6                0,1          0,1         0,1          0,1        -40          30           3
        1      20,09        -39,6                0,1          0,1         0,1          0,1        -40          30           3
        2      20,08        -39,6                0,1          0,1         0,1          0,1        -40          30           3
        3      20,06        -39,6                0,1          0,1         0,1          0,1        -40          30           3
        4      20,05        -39,5                0,2          0,1         0,1          0,1        -40          30           3
        5      20,05        -39,5                0,2          0,1         0,1          0,1        -40          30           3
        6      20,02        -39,5                0,2          0,1         0,1          0,1        -40          30           3
        8      19,95        -39,5                0,2          0,1         0,1          0,1        -40          30           3
       10      19,83        -39,4                0,2          0,1         0,2          0,1        -40          30           3
       12      19,71        -39,4                0,2          0,1         0,2          0,1        -40          30           3
       14      19,54        -39,4                0,2          0,1         0,2          0,1        -40          30           3
       16      19,53        -39,3                0,3          0,1         0,2          0,1        -40          30           3
       18      19,50        -39,3                0,3          0,1         0,2          0,1        -40          30           3
       20      19,57        -39,3                0,3          0,1         0,2          0,1        -40          30           3
       22      19,61        -39,3                0,3          0,1         0,2          0,1        -40          30           3
       24      19,61        -39,3                0,3          0,1         0,2          0,1        -40          30           3
       26      19,54        -39,3                0,3          0,1         0,2          0,1        -40          30           3
       28      19,46        -39,2                0,3          0,1         0,3          0,1        -40          30           3
       30      19,73        -39,1                0,4          0,1         0,3          0,1        -40          30           3

Sample calculation

E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
U = Receiver reading
AF = Antenna factor
Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
distance correction = -40 * LOG (dLimit/ dused)
Linear interpolation will be used for frequencies in between the values in the table.
Table shows an extract of values




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                                              Page 23 of 29


6.3    Antenna R&S HL562 (30 MHz – 1 GHz)
(dLimit = 3 m)
                                             cable       cable         cable       cable     distance     dLimit       dused
                 AF                          loss 1      loss 2       loss 3      loss 4       corr.     (meas.       (meas.
                R&S                         (inside     (outside     (switch        (to      (-20 dB/   distance     distance
 Frequency     HL562        Corr.          chamber)    chamber)        unit)    receiver)    decade)     (limit)      (used)
    MHz       dB (1/m)       dB                dB          dB           dB          dB          dB          m           m
        30        18,6         0,6              0,29        0,04         0,23         0,02        0,0            3           3
        50         6,0         0,9              0,39        0,09         0,32         0,08        0,0            3           3
       100         9,7         1,2              0,56        0,14         0,47         0,08        0,0            3           3
       150         7,9         1,6              0,73        0,20         0,59         0,12        0,0            3           3
       200         7,6         1,9              0,84        0,21         0,70         0,11        0,0            3           3
       250         9,5         2,1              0,98        0,24         0,80         0,13        0,0            3           3
       300        11,0         2,3              1,04        0,26         0,89         0,15        0,0            3           3
       350        12,4         2,6              1,18        0,31         0,96         0,13        0,0            3           3
       400        13,6         2,9              1,28        0,35         1,03         0,19        0,0            3           3
       450        14,7         3,1              1,39        0,38         1,11         0,22        0,0            3           3
       500        15,6         3,2              1,44        0,39         1,20         0,19        0,0            3           3
       550        16,3         3,5              1,55        0,46         1,24         0,23        0,0            3           3
       600        17,2         3,5              1,59        0,43         1,29         0,23        0,0            3           3
       650        18,1         3,6              1,67        0,34         1,35         0,22        0,0            3           3
       700        18,5         3,6              1,67        0,42         1,41         0,15        0,0            3           3
       750        19,1         4,1              1,87        0,54         1,46         0,25        0,0            3           3
       800        19,6         4,1              1,90        0,46         1,51         0,25        0,0            3           3
       850        20,1         4,4              1,99        0,60         1,56         0,27        0,0            3           3
       900        20,8         4,7              2,14        0,60         1,63         0,29        0,0            3           3
       950        21,1         4,8              2,22        0,60         1,66         0,33        0,0            3           3
      1000        21,6         4,9              2,23        0,61         1,71         0,30        0,0            3           3


(dLimit = 10 m)
          30      18,6         -9,9             0,29         0,04        0,23        0,02       -10,5          10           3
          50       6,0         -9,6             0,39         0,09        0,32        0,08       -10,5          10           3
         100       9,7         -9,2             0,56         0,14        0,47        0,08       -10,5          10           3
         150       7,9         -8,8             0,73         0,20        0,59        0,12       -10,5          10           3
         200       7,6         -8,6             0,84         0,21        0,70        0,11       -10,5          10           3
         250       9,5         -8,3             0,98         0,24        0,80        0,13       -10,5          10           3
         300      11,0         -8,1             1,04         0,26        0,89        0,15       -10,5          10           3
         350      12,4         -7,9             1,18         0,31        0,96        0,13       -10,5          10           3
         400      13,6         -7,6             1,28         0,35        1,03        0,19       -10,5          10           3
         450      14,7         -7,4             1,39         0,38        1,11        0,22       -10,5          10           3
         500      15,6         -7,2             1,44         0,39        1,20        0,19       -10,5          10           3
         550      16,3         -7,0             1,55         0,46        1,24        0,23       -10,5          10           3
         600      17,2         -6,9             1,59         0,43        1,29        0,23       -10,5          10           3
         650      18,1         -6,9             1,67         0,34        1,35        0,22       -10,5          10           3
         700      18,5         -6,8             1,67         0,42        1,41        0,15       -10,5          10           3
         750      19,1         -6,3             1,87         0,54        1,46        0,25       -10,5          10           3
         800      19,6         -6,3             1,90         0,46        1,51        0,25       -10,5          10           3
         850      20,1         -6,0             1,99         0,60        1,56        0,27       -10,5          10           3
         900      20,8         -5,8             2,14         0,60        1,63        0,29       -10,5          10           3
         950      21,1         -5,6             2,22         0,60        1,66        0,33       -10,5          10           3
        1000      21,6         -5,6             2,23         0,61        1,71        0,30       -10,5          10           3

Sample calculation
 E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
 U = Receiver reading
 AF = Antenna factor
 Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
 distance correction = -20 * LOG (dLimit/ dused)
 Linear interpolation will be used for frequencies in between the values in the table.
 Tables show an extract of values.




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                                              Page 24 of 29


6.4   Antenna R&S HF907 (1 GHz – 18 GHz)
                                                                     cable
                                             cable                   loss 3
                                            loss 1                  (switch
                                           (relay +      cable        unit,
                AF                           cable       loss 2     atten-        cable
               R&S                          inside      (outside    uator &     loss 4 (to
Frequency     HF907        Corr.          chamber)     chamber)    pre-amp)     receiver)
   MHz       dB (1/m)       dB                dB           dB          dB           dB
     1000        24,4       -19,4               0,99        0,31      -21,51         0,79
     2000        28,5       -17,4               1,44        0,44      -20,63         1,38
     3000        31,0       -16,1               1,87        0,53      -19,85         1,33
     4000        33,1       -14,7               2,41        0,67      -19,13         1,31
     5000        34,4       -13,7               2,78        0,86      -18,71         1,40
     6000        34,7       -12,7               2,74        0,90      -17,83         1,47
     7000        35,6       -11,0               2,82        0,86      -16,19         1,46

                                                                                  cable
                                                                                  loss 4
                                             cable                               (switch
                                            loss 1       cable       cable         unit,                    used
                AF                          (relay       loss 2      loss 3      atten-        cable        for
               R&S                          inside      (inside     (outside     uator &     loss 5 (to     FCC
Frequency     HF907        Corr.          chamber)     chamber)    chamber)     pre-amp)     receiver)      15.247
   MHz       dB (1/m)       dB                dB           dB          dB           dB           dB
     3000        31,0       -23,4               0,47        1,87        0,53       -27,58         1,33
     4000        33,1       -23,3               0,56        2,41        0,67       -28,23         1,31
     5000        34,4       -21,7               0,61        2,78        0,86       -27,35         1,40
     6000        34,7       -21,2               0,58        2,74        0,90       -26,89         1,47
     7000        35,6       -19,8               0,66        2,82        0,86       -25,58         1,46

                                             cable
                                            loss 1      cable        cable        cable        cable           cable
                AF                          (relay      loss 2       loss 3       loss 4       loss 5         loss 6
               R&S                          inside      (High         (pre-      (inside      (outside          (to
Frequency     HF907        Corr.          chamber)      Pass)        amp)       chamber)     chamber)       receiver)
   MHz       dB (1/m)       dB                dB          dB            dB          dB           dB             dB
     7000        35,6       -57,3               0,56       1,28        -62,72        2,66         0,94            1,46
     8000        36,3       -56,3               0,69       0,71        -61,49        2,84         1,00            1,53
     9000        37,1       -55,3               0,68       0,65        -60,80        3,06         1,09            1,60
    10000        37,5       -56,2               0,70       0,54        -61,91        3,28         1,20            1,67
    11000        37,5       -55,3               0,80       0,61        -61,40        3,43         1,27            1,70
    12000        37,6       -53,7               0,84       0,42        -59,70        3,53         1,26            1,73
    13000        38,2       -53,5               0,83       0,44        -59,81        3,75         1,32            1,83
    14000        39,9       -56,3               0,91       0,53        -63,03        3,91         1,40            1,77
    15000        40,9       -54,1               0,98       0,54        -61,05        4,02         1,44            1,83
    16000        41,3       -54,1               1,23       0,49        -61,51        4,17         1,51            1,85
    17000        42,8       -54,4               1,36       0,76        -62,36        4,34         1,53            2,00
    18000        44,2       -54,7               1,70       0,53        -62,88        4,41         1,55            1,91

Sample calculation

E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
U = Receiver reading
AF = Antenna factor
Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
Linear interpolation will be used for frequencies in between the values in the table.
Tables show an extract of values.




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                                                Page 25 of 29


6.5   Antenna EMCO 3160-09 (18 GHz – 26.5 GHz)
                                            cable        cable      cable         cable       cable
                AF                          loss 1      loss 2      loss 3       loss 4      loss 5
              EMCO                         (inside       (pre-     (inside      (switch        (to
Frequency    3160-09       Corr.          chamber)      amp)      chamber)        unit)    receiver)
   MHz       dB (1/m)       dB                dB          dB          dB           dB          dB
    18000        40,2       -23,5              0,72      -35,85        6,20         2,81         2,65
    18500        40,2       -23,2              0,69      -35,71        6,46         2,76         2,59
    19000        40,2       -22,0              0,76      -35,44        6,69         3,15         2,79
    19500        40,3       -21,3              0,74      -35,07        7,04         3,11         2,91
    20000        40,3       -20,3              0,72      -34,49        7,30         3,07         3,05
    20500        40,3       -19,9              0,78      -34,46        7,48         3,12         3,15
    21000        40,3       -19,1              0,87      -34,07        7,61         3,20         3,33
    21500        40,3       -19,1              0,90      -33,96        7,47         3,28         3,19
    22000        40,3       -18,7              0,89      -33,57        7,34         3,35         3,28
    22500        40,4       -19,0              0,87      -33,66        7,06         3,75         2,94
    23000        40,4       -19,5              0,88      -33,75        6,92         3,77         2,70
    23500        40,4       -19,3              0,90      -33,35        6,99         3,52         2,66
    24000        40,4       -19,8              0,88      -33,99        6,88         3,88         2,58
    24500        40,4       -19,5              0,91      -33,89        7,01         3,93         2,51
    25000        40,4       -19,3              0,88      -33,00        6,72         3,96         2,14
    25500        40,5       -20,4              0,89      -34,07        6,90         3,66         2,22
    26000        40,5       -21,3              0,86      -35,11        7,02         3,69         2,28
    26500        40,5       -21,1              0,90      -35,20        7,15         3,91         2,36

Sample calculation

E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
U = Receiver reading
AF = Antenna factor
Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
Linear interpolation will be used for frequencies in between the values in the table.
Table shows an extract of values.




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                                              Page 26 of 29


6.6    Antenna EMCO 3160-10 (26.5 GHz – 40 GHz)
                                             cable        cable        cable       cable    distance      dLimit       dused
                 AF                          loss 1       loss 2      loss 3      loss 4      corr.      (meas.       (meas.
               EMCO                         (inside      (outside    (switch        (to     (-20 dB/    distance     distance
 Frequency    3160-10       Corr.          chamber)     chamber)       unit)    receiver)   decade)      (limit)      (used)
    GHz       dB (1/m)       dB                dB           dB          dB          dB         dB           m           m
      26,5        43,4       -11,2                4,4                                          -15,6             3         0,5
      27,0        43,4       -11,2                4,4                                          -15,6             3         0,5
      28,0        43,4       -11,1                4,5                                          -15,6             3         0,5
      29,0        43,5       -11,0                4,6                                          -15,6             3         0,5
      30,0        43,5       -10,9                4,7                                          -15,6             3         0,5
      31,0        43,5       -10,8                4,7                                          -15,6             3         0,5
      32,0        43,5       -10,7                4,8                                          -15,6             3         0,5
      33,0        43,6       -10,7                4,9                                          -15,6             3         0,5
      34,0        43,6       -10,6                5,0                                          -15,6             3         0,5
      35,0        43,6       -10,5                5,1                                          -15,6             3         0,5
      36,0        43,6       -10,4                5,1                                          -15,6             3         0,5
      37,0        43,7       -10,3                5,2                                          -15,6             3         0,5
      38,0        43,7       -10,2                5,3                                          -15,6             3         0,5
      39,0        43,7       -10,2                5,4                                          -15,6             3         0,5
      40,0        43,8       -10,1                5,5                                          -15,6             3         0,5

Sample calculation

 E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
 U = Receiver reading
 AF = Antenna factor
 Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
 Linear interpolarisation will be used for frequencies in between the values in the table.
 distance correction = -20 * LOG (dLimit/ dused)
 Linear interpolation will be used for frequencies in between the values in the table.
 Table shows an extract of values.




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                                              Page 27 of 29


7 Setup Drawings




Drawing 1: Setup in the Anechoic chamber. For measurements below 1 GHz the ground was
           replaced by a conducting groundplane.



   Rubidium              Spectrum                                   OUT
   Frequency             Analyser                                  (object
    Standard                                 Shielded RF cable   under test)


Drawing 2: Setup for conducted radio tests.




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                                     Page 28 of 29


8 Measurement Uncertainties


   Test Case                                 Parameter   Uncertainty
   AC Power Line                             Power       ± 3.4 dB

   Field Strength of spurious radiation      Power       ± 5.5 dB

   6 dB / 26 dB / 99% Bandwidth              Power       ± 2.9 dB
                                             Frequency   ± 11.2 kHz
   Conducted Output Power                    Power       ± 2.2 dB

   Band Edge Compliance                      Power       ± 2.2 dB
                                             Frequency   ± 11.2 kHz
   Frequency Stability                       Frequency   ± 25 Hz

   Power Spectral Density                    Power       ± 2.2 dB




9 Photo Report

Please see separate photo report.




TEST REPORT REFERENCE: MDE_UBLOX_1701_FCCb                          Page 29 of 29



Document Created: 2018-03-22 17:40:59
Document Modified: 2018-03-22 17:40:59

© 2024 FCC.report