Test Report

FCC ID: XPY1EIQN2NN

Test Report

Download: PDF
FCCID_3165127

FCC Measurement/Technical Report on

LARA—R204
According to: FCC Part 15, Subpart B



FCC ID: XPY1 EIQN2Z2NN
1IC: 8595A¥—1EIQN2NN


Test Report Reference: MDE_UBLOX_1603_FCCb




 Test Laboratory:
 7layers GmbH
 Borsigstrasse 11                                                                     ((( DAkkS
 40880 Ratingen                                                                              Deutsche
                                                                                             Abkreditierungsstelle
 Germany                                                                                            b—Pi—t2140.01—01
 Note
 The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts
 without the written approval of the test laboratory:
 Tlayers GmbH                       Goschifteithro
 Borsigstratle 11                   Managing Diractors                 Regist argaricht/ragistered                           a Bureau Vertas
 40880 Ratingen, Garm any           Frank Spiler                       Dlissaldort HRB 75584                                 Group Company
 T+49 (0) 2102 7« 0                 Bormhard Retka                     US—Id.—Nr/VAT—No. De203159032
 F»48 (0) 2102 749 aso              Alexandire Norré—Oudard            Steuer—Nr./TAX—No. 1477580970305                      wan.Zlayers.com

 Commerzbank AG Account No. 303018000 Bank Code 30040000             IBAN DE81800400000308016000         Swit Code COBADEFF


Table of Contents

1     Applied Standards and Test Summary                        3
1.1   Applied Standards                                          3
1.2   FCC-IC Correlation Table                                   4
1.3   Measurement Summary / Signatures                           5

2     Administrative Data                                       6
2.1   Testing Laboratory                                         6
2.2   Project Data                                               6
2.3   Applicant Data                                             6
2.4   Manufacturer Data                                          6

3     Test object Data                                          7
3.1   General EUT Description                                    7
3.2   EUT Main components                                        7
3.3   Ancillary Equipment                                        7
3.4   Auxiliary Equipment                                        8
3.5   EUT Setups                                                 8
3.6   Operating Modes                                            9
3.7   Product labelling                                          9

4     Test Results                                            10
4.1   Conducted Emissions at AC mains                          10
4.2   Radiated Emissions                                       13

5     Test Equipment                                          17

6     Antenna Factors, Cable Loss and Sample Calculations     20
6.1   LISN R&S ESH3-Z5 (150 kHz – 30 MHz)                      20
6.2   Antenna R&S HFH2-Z2 (9 kHz – 30 MHz)                     21
6.3   Antenna R&S HL562 (30 MHz – 1 GHz)                       22
6.4   Antenna R&S HF907 (1 GHz – 18 GHz)                       23
6.5   Antenna EMCO 3160-09 (18 GHz – 26.5 GHz)                 24
6.6   Antenna EMCO 3160-10 (18 GHz – 26.5 GHz)                 25

7     Setup Drawings                                          26

8     Measurement Uncertainties                               27

9     Photo Report                                            27




TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                  Page 2 of 27


1     APPLIED STANDARDS AND TEST SUMMARY

1.1    APPLIED STANDARDS


Applicable FCC Rules

Prepared in accordance with the requirements of FCC Rules and Regulations as listed in 47 CFR
Ch.1 Parts 2 and 15 (10-1-15 Edition). The following subparts are applicable to the results in
this test report.


Part 2, Subpart J - Equipment Authorization Procedures, Certification

Part 15, Subpart B – Unintentional Radiators

§ 15.107   Conducted limits

§ 15.109   Radiated emission limits; general requirements


Note:
ANSI C63.4–2014 is applied.




 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                        Page 3 of 27


Summary Test Results:

The EUT complied with all performed tests as listed in chapter 1.3 Measurement
Summary / Signatures.


1.2   FCC-IC CORRELATION TABLE


Correlation of measurement requirements for
               Information Technology Equipment (ITE)
                                from
                             FCC and IC

 Measurement                   FCC reference               IC reference
 Conducted Emissions           §15.107                     ICES-003 Issue 6: 6.1
 (AC Power Line)
 Radiated Spurious Emissions   §15.109                     ICES-003 Issue 6: 6.2


Remarks:

1. FCC Part 15 subpart B, ICES 003 and CISPR 22 contain different definitions of Class A and
   Class B limits, i.e. which class is applicable to which kind of EUT.
   ICES 003 and CISPR 22 distinguish between the location where the EUT is intended to
   operate whilst FCC refers to the method of commercial distribution (distributive trades).
2. The correct assignment of the appropriate class to the concrete EUT is not scope of this
   test report!
3. A radio apparatus that is specifically subject to an Industry Canada Radio Standard
   Specification (RSS) and which contains an ITE is not subject to ICES-003 provided the ITE
   is used only to enable operation of the radio apparatus and the ITE does not control
   additional functions or capabilities.
4. ISM (Industrial, Scientific or Medical) radio frequency generators, though they may contain
   ITE, are excluded from the definition of ITE and are not subject to ICES-003. They are
   instead subject to the Interference-Causing Equipment Standard ICES-001, which
   specifically addresses ISM radio frequency generators.




 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                        Page 4 of 27


                                                                          %layers  A Bureau Veritas Group Company




1.3    MEASUREMENT SUMMARY / SIGNATURES


47 CFR CHAPTER I FCC PART 15 Subpart B                      § 15.107
Conducted Emissions at AC mains
The measurement was performed according to ANSI C63.4                            Final Result

OP—Mode                                                         Setup            FCC              IC
AC mains connection, Test setup
via connected computer device, computer peripheric              S01_AYO2         Passed           Passed



47 CFR CHAPTER I FCC PART 15 Subpart B              § 15.109
Radiated Emissions
The measurement was performed according to ANSI C63.4                            Final Result

OP—Mode                                                         Setup            FCC              IC
AC mains connection, Measurementrange, Test setup
via connected computer device, 1 GHz — 10 GHz, computer         S01_AYO2         Passed           Passed
peripheric
via connected computer device, 30 MHz — 1 GHz, computer         S01_AYO2         Passed           Passed
peripheric




      @i     (responsible for accreditation
                                                      Q/L_(responsible for testing and report)
        scope) Dipl. Bernhard Retka                                Patrick Lomax




TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                                       Page 5 of 27


2     ADMINISTRATIVE DATA

2.1    TESTING LABORATORY

Company Name:                            7layers GmbH

Address:                                 Borsigstr. 11
                                         40880 Ratingen
                                         Germany

This facility has been fully described in a report submitted to the FCC and accepted under
the registration number 96716.
This facility has been fully described in a report submitted to the IC and accepted under the
registration number: Site# 3699A-1.
The test facility is also accredited by the following accreditation organisation:
Laboratory accreditation no:             DAkkS D-PL-12140-01-01

Responsible for accreditation scope:     Dipl. Marco Kullik

Report Template Version:                 2016-06-07


2.2    PROJECT DATA

Responsible for testing and report:      Patrick Lomax

Employees who performed the tests:       documented internally at 7Layers

Date of Report:                          2016-09-24

Testing Period:                          2016-09-10 to 2016-09-22


2.3    APPLICANT DATA

Company Name:                            u-blox AG

Address:                                 Zürcherstrasse 68
                                         CH-8800 Thalwil
                                         Switzerland

Contact Person:                          Giulio Comar


2.4    MANUFACTURER DATA

Company Name:                            See applicant data

Address:



Contact Person:



 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                          Page 6 of 27


3     TEST OBJECT DATA

3.1     GENERAL EUT DESCRIPTION

Kind of Device                   LTE Data module
product description
Product name                     LARA-R204
Type                             LARA-R204

Declared EUT data by the supplier
Power Supply Type                DC
Comment                          DC Power via AC/DC adapter
Test Voltage /                   120v/60Hz AC
Frequency
Highest internal                 Above 108 MHz
frequency
General Description              UMTS/LTE Voice and Data module
Ports                            USB, RF

The main components of the EUT are listed and described in chapter 3.2 EUT Main
components.


3.2     EUT MAIN COMPONENTS

Sample Name                       Sample Code                                 Description
Standard Sample                   AY02                                        Standard sample
   Sample Parameter                                                       Value
HW Version                        266A00
Serial No.                        357648070021592
SW Version                        31.02

NOTE:The short description is used to simplify the identification of the EUT in this test report.




3.3     ANCILLARY EQUIPMENT

For the purposes of this test report, ancillary equipment is defined as equipment which is used
in conjunction with the EUT to provide operational and control features to the EUT. It is
necessary to configure the system in a typical fashion, as a customer would normally use it.
But nevertheless Ancillary Equipment can influence the test results.

Device                            Details                                                Description
                                  (Manufacturer, Type Model, OUT
                                  Code)
AC/DC converter                   UNIFIVE, UUX324-1215, DE1015039                        120v/60Hz to 12v
                                                                                         AC/DC converter


 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                                            Page 7 of 27


Device                       Details                                       Description
                             (Manufacturer, Type Model, OUT
                             Code)
Sample Name                  Description
AC/DC converter              AC/DC converter
Evaluation test board        u-blox, EVB-WL3, DE1015039                    Evaluation test board

Sample Name                  Description
Evaluation test board        Evaluation test board



3.4   AUXILIARY EQUIPMENT

For the purposes of this test report, auxiliary equipment is defined as equipment which is used
temporarily to enable operational and control features especially used for the tests of the EUT
which is not used during normal operation or equipment that is used during the tests in
combination with the EUT but is not subject of this test report. It is necessary to configure the
system in a typical fashion, as a customer would normally use it.
But nevertheless Auxiliary Equipment can influence the test results.

Device                        Details                                      Description
                              (Manufacturer, HW, SW, S/N)
L17MB-P                       LG, -, -, 412WAPL0U560                       TFT Display EMC TFT 5

Lifebook Eseries E781         Fujitsu, -, -, DSCK013817                    Laptop RE

M-BT58                        Logitech, -, -, HC60915A2XC                  EMC MOUSE 1

PJW1942NA                     Fujitsu, -, -, 13300281B                     AC Adapter 3 Laptop
                                                                           RE
RS 6000 USB ON                CHERRY, -, -, G 0000273 2P28                 EMC KEYBOARD 1




3.5   EUT SETUPS

This chapter describes the combination of EUTs and equipment used for testing. The rationale
for selecting the EUTs, ancillary and auxiliary equipment and interconnecting cables, is to test
a representative configuration meeting the requirements of the referenced standards.

   Setup     Combination of EUTs                       Description and Rationale
                Standard Sample,       Standard radiated setup used for connecting module to a
              Evaluation test board,   laptop computer (Windows 7 Pro) via USB. Continuous
                AC/DC converter,       communication is maintained over the USB interface by the
 S01_AY02    L17MB-P, PJW1942NA,
                                       use of AT command scripts.
             Lifebook Eseries E781,
             M-BT58, RS 6000 USB
                       ON,




 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                                Page 8 of 27


3.6   OPERATING MODES
This chapter describes the operating modes of the EUTs used for testing.

       3.6.1TEST CHANNELS

Testing performed in UMTS FDD4, Channel 20175 (1732.50 MHz)


3.7   PRODUCT LABELLING


       3.7.1 FCC ID LABEL
Please refer to the documentation of the applicant.


       3.7.2 LOCATION OF THE LABEL ON THE EUT
Please refer to the documentation of the applicant.




 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                Page 9 of 27


4     TEST RESULTS



4.1    CONDUCTED EMISSIONS AT AC MAINS

Standard      FCC Part 15 Subpart B

The test was performed according to:
ANSI C63.4

        4.1.1 TEST DESCRIPTION

The test set-up was made in accordance to the general provisions of ANSI C 63.4
The Equipment Under Test (EUT) was setup in a shielded room to perform the conducted
emissions measurements in a typical installation configuration. The EUT was powered from
50µH || 50 Ohm Line Impedance Stabilization Network (LISN). The LISN’s unused connections
were terminated with 50 Ohm loads.

The measurement procedure consists of two steps. It is implemented into the EMI test
software EMC-32 from R&S.

Step 1: Preliminary scan
Intention of this step is, to determine the conducted EMI-profile of the EUT.
EMI receiver settings:
- Detector: Peak – Maxhold & Average
- Frequency range: 150 kHz – 30 MHz
- Frequency steps: 2.5 kHz
- IF–Bandwidth: 9 kHz
- Measuring time / Frequency step: 100 ms (FFT-based)
- Measurement on phase + neutral lines of the power cords

On basis of this preliminary scan the highest amplitudes and the corresponding frequencies
relative to the limit are identified. Emissions above the limit and emissions which are in the 10
dB range below the limit are considered.

Step 2: Final measurement
Intention of this step is, to determine the highest emissions with the settings defined in the
test specification for the frequencies identified in step 1.
EMI receiver settings:
- Detector: Quasi-Peak
- IF Bandwidth: 9 kHz
- Measuring time: 1 s / frequency

At each frequency determined in step 1, four measurements are performed in the following
combinations:
1) Neutral lead - reference ground (PE grounded)
2) Phase lead - reference ground (PE grounded)
3) Neutral lead - reference ground (PE floating)
4) Phase lead - reference ground (PE floating)

The highest value is reported.




 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                          Page 10 of 27


        4.1.2 TEST REQUIREMENTS / LIMITS

FCC Part 15, Subpart B, §15.107

Class B:
 Frequency (MHz)      QP Limits (dBµV)   AV Limits (dBµV)
 0.15 – 0.5           66 - 56            56 - 46
 0.5 - 5              56                 46
 5 - 30               60                 50


Class A:
 Frequency (MHz)      QP Limits (dBµV)   AV Limits (dBµV)
 0.15 – 0.5           79                 66
 0.5 - 30             73                 60



        4.1.3 TEST PROTOCOL

Power line       PE    Frequency [MHz] Level [dBµV] Detector Limit [dBµV] Margin [dB]
     L1        GND                0.4          38.4         AV   47.1         8.8
     L1        GND                0.4          45.9         QP   57.1        11.2
      N          FL               4.2          36.5         QP   56.0        19.5
     L1        GND                4.3          36.3         AV   46.0         9.7
      N        GND                5.0          35.1         QP   56.0        20.9
     L1        GND                5.1          36.6         AV   50.0        13.4
     L1        GND                15.4         35.7         AV   50.0        14.4
     L1        GND                18.0         39.0         AV   50.0        11.0
     L1        GND                18.0         40.6         QP   60.0        19.4
     L1        GND                18.9         40.6         QP   60.0        19.4
     L1        GND                18.9         38.2         AV   50.0        11.8
     L1        GND                19.2         38.5         QP   60.0        21.5
     L1        GND                19.7         37.3         QP   50.0        12.7
      N        GND                20.8         39.7         QP   60.0        20.3
      N        GND                22.3         35.6         AV   50.0        14.4
     L1        GND                24.0         41.0         AV   50.0         9.1
     L1        GND                24.0         42.6         QP   60.0        17.4
     L1        GND                24.9         39.3         AV   50.0        10.7
     L1        GND                24.9         42.1         QP   60.0        17.9
     L1        GND                25.0         41.3         QP   60.0        18.7

 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                 Page 11 of 27


                       4.1.4 MEASUREMENT PLOT (SHOWING THE HIGHEST VALUE, “WORST CASE”)
                AC mains connection = via connected computer device, Test setup = computer peripheral



                80


                70

                                                                                                        Limit_15_107_QP_ClassB
                60

                                                                                                        Limit_15_107_AV_ClassB
                50
Level in dBµV




                40


                30


                20


                10


                0
                150k        300   400   500   800   1M       2M            3M   4M   5M   6   8   10M          20M         30M
                                                         Frequency in Hz




                       4.1.5 TEST EQUIPMENT USED
Conducted Emissions FCC




         TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                                          Page 12 of 27


4.2   RADIATED EMISSIONS

Standard      FCC Part 15 Subpart B

The test was performed according to:
ANSI C63.4

       4.2.1 TEST DESCRIPTION

The test set-up was made in accordance to the general provisions of ANSI C63.4 in a typical
installation configuration. The Equipment Under Test (EUT) was set up on a non-conductive
table 1.0 x 2.0 m² in the semi-anechoic chamber. The influence of the EUT support table that
is used between 30–1000 MHz was evaluated.
The measurement procedure is implemented into the EMI test software EMC32 from R&S.
Exploratory tests are performed at 3 orthogonal axes to determine the worst-case orientation
of a body-worn or handheld EUT. The final test on all kind of EUTs is also performed at 3 axes.
A pre-check is performed while the EUT is powered from a DC power source.

1. Measurement above 30 MHz and up to 1 GHz

Step 1: Preliminary scan
This is a preliminary test to identify the highest amplitudes relative to the limit.
Settings for step 1:
- Antenna distance: 3 m
- Detector: Peak-Maxhold / Quasipeak (FFT-based)
- Frequency range: 30 – 1000 MHz
- Frequency steps: 30 kHz
- IF–Bandwidth: 120 kHz
- Measuring time / Frequency step: 100 ms
- Turntable angle range: –180° to 90°
- Turntable step size: 90°
- Height variation range: 1 – 3 m
- Height variation step size: 2 m
- Polarisation: Horizontal + Vertical
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.

Step 2: Adjustment measurement
In this step the accuracy of the turntable azimuth and antenna height will be improved. This is
necessary to find out the maximum value of every frequency.
For each frequency, which was determined the turntable azimuth and antenna height will be
adjusted. The turntable azimuth will slowly vary by ± 45° around this value. During this action,
the value of emission is continuously measured. The turntable azimuth at the highest emission
will be recorded and adjusted. In this position, the antenna height will also slowly vary by ±
100 cm around the antenna height determined. During this action, the value of emission is
also continuously measured. The antenna height of the highest emission will also be recorded
and adjusted.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: ± 45 ° around the determined value
- Height variation range: ± 100 cm around the determined value
- Antenna Polarisation: max. value determined in step 1


 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                          Page 13 of 27


Step 3: Final measurement with QP detector
With the settings determined in step 3, the final measurement will be performed:
EMI receiver settings for step 4:
- Detector: Quasi-Peak (< 1 GHz)
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 1 s

After the measurement a plot will be generated which contains a diagram with the results of
the preliminary scan and a chart with the frequencies and values of the results of the final
measurement.

3. Measurement above 1 GHz
The following modifications apply to the measurement procedure for the frequency range
above 1 GHz:
Step 1:
The Equipment Under Test (EUT) was set up on a non-conductive support (tilt device) at 1.5 m
height in the fully-anechoic chamber.
All steps were performed with one height (1.5 m) of the receiving antenna only.
The EUT is turned during the preliminary measurement across the elevation axis, with a step
size of 90 °.
The turn table step size (azimuth angle) for the preliminary measurement is 45 °.
Step 2:
Due to the fact, that in this frequency range the test is performed in a fully anechoic room, the
height scan of the receiving antenna instep 2 is omitted. Instead of this, a maximum search
with a step size ± 45° for the elevation axis is performed.
The turn table azimuth will slowly vary by ± 22.5°.
The elevation angle will slowly vary by ± 45°
EMI receiver settings (for all steps):
- Detector: Peak, Average
- IF Bandwidth = 1 MHz
Step 3:
Spectrum analyser settings for step 3:
- Detector: Peak / Average
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 1 MHz
- Measuring time: 1 s


       4.2.2 TEST REQUIREMENTS / LIMITS

FCC Part 15, Subpart B, §15.109, Radiated Emission Limits

Class B:
                                       Measurement
 Frequency (MHz)   Limit (µV/m)                        Limits (dBµV/m)
                                       distance (m)
 30 – 88           100@3m              3               40.0@3m
 88 – 216          150@3m              3               43.5@3m
 216 – 960         200@3m              3               46.0@3m
 960 - 26000       500@3m              3               54.0@3m
 26000 - 40000     500@3m              1               54.0@3m


Class A:
                                       Measurement
 Frequency (MHz)   Limit (µV/m)                        Limits (dBµV/m)
                                       distance (m)
 30 – 88           90@10m              3               39.1@10m
 88 – 216          150@10m             3               43.5@10m

 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                         Page 14 of 27


 216 – 960           210@10m                 3                 46.4@10m
 960 - 26000         300@10m                 3                 49.5@10m
 26000 - 40000       300@10m                 1                 49.5@10m




The measured values for Class A and for Class B (> 26 GHz) measurements are corrected with
an inverse linear distance extrapolation factor (20 dB/decade).

§15.35(b) ..., there is also a limit on the radio frequency emissions, as measured using
instrumentation with a peak detector function, corresponding to 20 dB above the maximum
permitted average limit....

Used conversion factor: Limit (dBµV/m) = 20 log (Limit (µV/m)/1µV/m)


        4.2.3 TEST PROTOCOL

  Spurious Freq.          Spurious Level                       RBW          Limit    Margin to
                                                 Detector
     [MHz]                  [dBµV/m]                           [kHz]      [dBµV/m]   Limit [dB]
        39.5                     36.4               QP         120.0        40.0        3.6
        48.5                     30.6               QP         120.0        40.0        9.4
        69.8                     29.5               QP         120.0        40.0        10.5
        82.1                     25.9               QP         120.0        40.0        14.1
        86.2                     25.5               QP         120.0        40.0        14.5
        117.7                    28.8               QP         120.0        43.5        14.7
        133.4                    33.0               QP         120.0        43.5        10.5
        194.8                    36.3               QP         120.0        43.5        7.2
        356.2                    30.6               QP         120.0        46.0        15.4


Remark: Please see next sub-clause for the measurement plot.




 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                            Page 15 of 27


                       4.2.4 MEASUREMENT PLOT (SHOWING THE HIGHEST VALUE, “WORST CASE”)




AC mains connection = via connected computer device, Measurement range = 1 GHz - 10 GHz,
                             Test setup = computer peripheral


                       104
                       100

                       95

                       90

                       85

                       80

                       75
     Level in dBµV/m




                       70

                       65

                       60

                       55

                       50

                       45

                       40

                       35

                       30

                       24
                        1G                2G          3G               4G    5G         6           8   10G              13G

                                                           Frequency in Hz


  AC mains connection = via connected computer device, Measurement range = 30 MHz - 1
                          GHz, Test setup = computer peripheral


                       60
                                                                                                              FCC_15b_ClassB

                       50


                       40
     Level in dBµV/m




                       30


                       20



                       10


                       0




                       30M      50   60   80   100M                    200        300       400   500           800      1G
                                                           Frequency in Hz




                       4.2.5TEST EQUIPMENT USED
Radiated Emissions FAR
Radiated Emissions SAC




TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                                                     Page 16 of 27


5     TEST EQUIPMENT
1        Radiated Emissions FAR
         Lab to perform radiated emission tests i a fully anechoic room


Ref.No. Device Name        Description     Manufacturer     Serial Number       Last     Calibration
                                                                             Calibration     Due
1.1      WHKX 7.0/18G- High Pass Filter Wainwright          09
         8SS
1.2      5HC3500/1800 High Pass Filter Trilithic            200035008
         0-1.2-KK
1.3      Fully Anechoic   8.80m x 4.60m Albatross Projects P26971-647-
         Room             x 4.05m (l x w                   001-PRB
                          x h)
1.4      TT 1.5 WI        Turn Table     Maturo GmbH        -


1.5      Fluke 177        Digital       Fluke Europe B.V.   86670383         2016-02    2018-02
                          Multimeter 03
                          (Multimeter)
1.6      Tilt device      Antrieb TD1.5- Maturo GmbH        TD1.5-
         Maturo           10kg                              10kg/024/37907
         (Rohacell)                                         09
1.7      5HC2700/1275 High Pass Filter Trilithic            9942012
         0-1.5-KK
1.8      4HC1600/1275 High Pass Filter Trilithic            9942011
         0-1.5-KK
1.9      ASP 1.2/1.8-10 Antenna Mast     Maturo GmbH        -
         kg
1.10     JS4-18002600- Broadband         Miteq              849785
         32-5P         Amplifier 18
                       GHz - 26 GHz
1.11     JS4-00101800- Broadband         Miteq              896037
         35-5P         Amplifier 30
                       MHz - 18 GHz
1.12     Opus10 THI       ThermoHygro Lufft Mess- und       12482            2015-03    2017-03
         (8152.00)        Datalogger 12 Regeltechnik
                          (Environ)     GmbH
1.13     JS4-00102600- Broadband         Miteq              619368
         42-5A         Amplifier 30
                       MHz - 26 GHz
1.14     FSW 43           Spectrum       Rohde & Schwarz    103779           2014-11    2016-11
                          Analyzer
1.15     SMR 20           Signal         Rohde & Schwarz    846834/008       2014-06    2017-06
                          Generator
1.16     HL 562 Ultralog Log.-per.       Rohde & Schwarz    100609           2016-04    2019-04
                         Antenna
1.17     PAS 2.5 - 10 kg Antenna Mast    Maturo GmbH        -


1.18     HF 907           Double-ridged Rohde & Schwarz     102444           2015-05    2018-05
                          horn


 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                             Page 17 of 27


2       Conducted Emissions FCC
        Conducted Emissions power line for FCC standards


Ref.No. Device Name     Description       Manufacturer    Serial Number      Last     Calibration
                                                                          Calibration     Due
2.1     ESH 3-Z5       Two-Line V-      Rohde & Schwarz   828304/029      2015-03    2017-03
                       Network
2.2     ESR 7          EMI Receiver / Rohde & Schwarz     101424          2014-11    2016-11
                       Spectrum
                       Analyzer
2.3     EP 1200/B,     Amplifier with   Spitzenberger &   B6278           2015-07    2018-07
        NA/B1          integrated       Spieß
                       variable
                       Oscillator
2.4     Fluke 177      Digital       Fluke Europe B.V.    86670383        2016-02    2018-02
                       Multimeter 03
                       (Multimeter)
2.5     Shielded Room Shielded Room Frankonia             -
        02            for conducted
                      testing, 12qm
2.6     ESIB 26        Spectrum         Rohde & Schwarz   830482/004      2015-12    2017-12
                       Analyzer
2.7     Opus10 THI     ThermoHygro Lufft Mess- und        7489            2015-02    2017-02
        (8152.00)      Datalogger 02 Regeltechnik
                       (Environ)     GmbH
2.8     ESH 3-Z5       Two-Line V-      Rohde & Schwarz   829996/002      2015-03    2017-03
                       Network
2.9     Opus10 TPR     ThermoAirpres Lufft Mess- und      13936           2015-02    2017-02
        (8253.00)      sure          Regeltechnik
                       Datalogger 13 GmbH
                       (Environ)
2.10    Chroma 6404    AC Power         Chroma ATE INC.   64040001304
                       Source

3       Radiated Emissions SAC
        Lab to perform radiated emission tests in semi anechoic configuration


Ref.No. Device Name     Description       Manufacturer    Serial Number      Last     Calibration
                                                                          Calibration     Due
3.1     Anechoic       10.58 x 6.38 x Frankonia           none            2014-01    2017-01
        Chamber        6.00 m³
3.2     Air compressor none                               none


3.3     MCU            Controller       Maturo GmbH       961208
                       Maturo
3.4     BB4312-C30-    Filter Universal Siemens&Matsushit none
        H3x            1A               a
3.5     CE-CAM/1       EMC camera       CE-SYS            none



 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                          Page 18 of 27


Ref.No. Device Name      Description     Manufacturer     Serial Number       Last     Calibration
                                                                           Calibration     Due
3.6     CO 2000        Controller      Innco innovative   CO2000/328/124
                       Innco 2000      constructions      70406/L
                                       GmbH
3.7     CCD-400E       EMC camera      Mitsubishi         0005033
                       Nr.2
3.8     B84312-C110- Filter ISDN       Siemens&Matsushit none
        E1                             a



The calibration interval is the time interval between “Last Calibration” and “Calibration Due”




 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                           Page 19 of 27


6     ANTENNA FACTORS, CABLE LOSS AND SAMPLE CALCULATIONS
This chapter contains the antenna factors with their corresponding path loss of the used
measurement path for all antennas as well as the insertion loss of the LISN.



6.1      LISN R&S ESH3-Z5 (150 KHZ – 30 MHZ)
                                                           cable
                                                LISN        loss
                                             insertion   (incl. 10
                                                loss         dB
                                               ESH3-      atten-
    Frequency                 Corr.              Z5       uator)
       MHz                     dB                dB          dB
         0,15                   10,1               0,1        10,0
            5                   10,3               0,1        10,2
            7                   10,5               0,2        10,3
           10                   10,5               0,2        10,3
           12                   10,7               0,3        10,4
           14                   10,7               0,3        10,4
           16                   10,8               0,4        10,4
           18                   10,9               0,4        10,5
           20                   10,9               0,4        10,5
           22                   11,1               0,5        10,6
           24                   11,1               0,5        10,6
           26                   11,2               0,5        10,7
           28                   11,2               0,5        10,7
           30                   11,3               0,5        10,8

Sample calculation

    ULISN (dB µV) = U (dB µV) + Corr. (dB)
    U = Receiver reading
    LISN Insertion loss = Voltage Division Factor of LISN
    Corr. = sum of single correction factors of used LISN, cables, switch units (if used)
    Linear interpolation will be used for frequencies in between the values in the table.




 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                                 Page 20 of 27


6.2    ANTENNA R&S HFH2-Z2 (9 KHZ – 30 MHZ)
                                               cable        cable       cable        cable     distance     dLimit      dused
                                              loss 1       loss 2      loss 3       loss 4       corr.     (meas.      (meas.
                  AF                         (inside      (outside    (switch         (to      (-40 dB/   distance    distance
  Frequency    HFH-Z2)       Corr.          chamber)     chamber)       unit)     receiver)    decade)     (limit)     (used)
     MHz       dB (1/m)       dB                dB           dB          dB           dB          dB          m          m
      0,009      20,50        -79,6                0,1          0,1         0,1          0,1        -80        300            3
       0,01      20,45        -79,6                0,1          0,1         0,1          0,1        -80        300            3
      0,015      20,37        -79,6                0,1          0,1         0,1          0,1        -80        300            3
       0,02      20,36        -79,6                0,1          0,1         0,1          0,1        -80        300            3
      0,025      20,38        -79,6                0,1          0,1         0,1          0,1        -80        300            3
       0,03      20,32        -79,6                0,1          0,1         0,1          0,1        -80        300            3
       0,05      20,35        -79,6                0,1          0,1         0,1          0,1        -80        300            3
       0,08      20,30        -79,6                0,1          0,1         0,1          0,1        -80        300            3
        0,1      20,20        -79,6                0,1          0,1         0,1          0,1        -80        300            3
        0,2      20,17        -79,6                0,1          0,1         0,1          0,1        -80        300            3
        0,3      20,14        -79,6                0,1          0,1         0,1          0,1        -80        300            3
       0,49      20,12        -79,6                0,1          0,1         0,1          0,1        -80        300            3
   0,490001      20,12        -39,6                0,1          0,1         0,1          0,1        -40          30           3
        0,5      20,11        -39,6                0,1          0,1         0,1          0,1        -40          30           3
        0,8      20,10        -39,6                0,1          0,1         0,1          0,1        -40          30           3
          1      20,09        -39,6                0,1          0,1         0,1          0,1        -40          30           3
          2      20,08        -39,6                0,1          0,1         0,1          0,1        -40          30           3
          3      20,06        -39,6                0,1          0,1         0,1          0,1        -40          30           3
          4      20,05        -39,5                0,2          0,1         0,1          0,1        -40          30           3
          5      20,05        -39,5                0,2          0,1         0,1          0,1        -40          30           3
          6      20,02        -39,5                0,2          0,1         0,1          0,1        -40          30           3
          8      19,95        -39,5                0,2          0,1         0,1          0,1        -40          30           3
         10      19,83        -39,4                0,2          0,1         0,2          0,1        -40          30           3
         12      19,71        -39,4                0,2          0,1         0,2          0,1        -40          30           3
         14      19,54        -39,4                0,2          0,1         0,2          0,1        -40          30           3
         16      19,53        -39,3                0,3          0,1         0,2          0,1        -40          30           3
         18      19,50        -39,3                0,3          0,1         0,2          0,1        -40          30           3
         20      19,57        -39,3                0,3          0,1         0,2          0,1        -40          30           3
         22      19,61        -39,3                0,3          0,1         0,2          0,1        -40          30           3
         24      19,61        -39,3                0,3          0,1         0,2          0,1        -40          30           3
         26      19,54        -39,3                0,3          0,1         0,2          0,1        -40          30           3
         28      19,46        -39,2                0,3          0,1         0,3          0,1        -40          30           3
         30      19,73        -39,1                0,4          0,1         0,3          0,1        -40          30           3

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  distance correction = -40 * LOG (dLimit/ dused)
  Linear interpolation will be used for frequencies in between the values in the table.
  Table shows an extract of values




 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                                                 Page 21 of 27


6.3    ANTENNA R&S HL562 (30 MHZ – 1 GHZ)
(dLimit = 3 m)
                                               cable        cable       cable       cable     distance     dLimit       dused
                    AF                        loss 1       loss 2      loss 3      loss 4       corr.     (meas.       (meas.
                   R&S                       (inside      (outside    (switch        (to      (-20 dB/   distance     distance
  Frequency       HL562      Corr.          chamber)     chamber)       unit)    receiver)    decade)     (limit)      (used)
     MHz         dB (1/m)     dB                dB           dB          dB          dB          dB          m           m
         30          18,6       0,6               0,29         0,04       0,23         0,02        0,0            3           3
         50           6,0       0,9               0,39         0,09       0,32         0,08        0,0            3           3
        100           9,7       1,2               0,56         0,14       0,47         0,08        0,0            3           3
        150           7,9       1,6               0,73         0,20       0,59         0,12        0,0            3           3
        200           7,6       1,9               0,84         0,21       0,70         0,11        0,0            3           3
        250           9,5       2,1               0,98         0,24       0,80         0,13        0,0            3           3
        300          11,0       2,3               1,04         0,26       0,89         0,15        0,0            3           3
        350          12,4       2,6               1,18         0,31       0,96         0,13        0,0            3           3
        400          13,6       2,9               1,28         0,35       1,03         0,19        0,0            3           3
        450          14,7       3,1               1,39         0,38       1,11         0,22        0,0            3           3
        500          15,6       3,2               1,44         0,39       1,20         0,19        0,0            3           3
        550          16,3       3,5               1,55         0,46       1,24         0,23        0,0            3           3
        600          17,2       3,5               1,59         0,43       1,29         0,23        0,0            3           3
        650          18,1       3,6               1,67         0,34       1,35         0,22        0,0            3           3
        700          18,5       3,6               1,67         0,42       1,41         0,15        0,0            3           3
        750          19,1       4,1               1,87         0,54       1,46         0,25        0,0            3           3
        800          19,6       4,1               1,90         0,46       1,51         0,25        0,0            3           3
        850          20,1       4,4               1,99         0,60       1,56         0,27        0,0            3           3
        900          20,8       4,7               2,14         0,60       1,63         0,29        0,0            3           3
        950          21,1       4,8               2,22         0,60       1,66         0,33        0,0            3           3
       1000          21,6       4,9               2,23         0,61       1,71         0,30        0,0            3           3


(dLimit = 10 m)
           30       18,6        -9,9             0,29         0,04        0,23        0,02       -10,5          10           3
           50        6,0        -9,6             0,39         0,09        0,32        0,08       -10,5          10           3
          100        9,7        -9,2             0,56         0,14        0,47        0,08       -10,5          10           3
          150        7,9        -8,8             0,73         0,20        0,59        0,12       -10,5          10           3
          200        7,6        -8,6             0,84         0,21        0,70        0,11       -10,5          10           3
          250        9,5        -8,3             0,98         0,24        0,80        0,13       -10,5          10           3
          300       11,0        -8,1             1,04         0,26        0,89        0,15       -10,5          10           3
          350       12,4        -7,9             1,18         0,31        0,96        0,13       -10,5          10           3
          400       13,6        -7,6             1,28         0,35        1,03        0,19       -10,5          10           3
          450       14,7        -7,4             1,39         0,38        1,11        0,22       -10,5          10           3
          500       15,6        -7,2             1,44         0,39        1,20        0,19       -10,5          10           3
          550       16,3        -7,0             1,55         0,46        1,24        0,23       -10,5          10           3
          600       17,2        -6,9             1,59         0,43        1,29        0,23       -10,5          10           3
          650       18,1        -6,9             1,67         0,34        1,35        0,22       -10,5          10           3
          700       18,5        -6,8             1,67         0,42        1,41        0,15       -10,5          10           3
          750       19,1        -6,3             1,87         0,54        1,46        0,25       -10,5          10           3
          800       19,6        -6,3             1,90         0,46        1,51        0,25       -10,5          10           3
          850       20,1        -6,0             1,99         0,60        1,56        0,27       -10,5          10           3
          900       20,8        -5,8             2,14         0,60        1,63        0,29       -10,5          10           3
          950       21,1        -5,6             2,22         0,60        1,66        0,33       -10,5          10           3
         1000       21,6        -5,6             2,23         0,61        1,71        0,30       -10,5          10           3

Sample calculation
  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  distance correction = -20 * LOG (dLimit/ dused)
  Linear interpolation will be used for frequencies in between the values in the table.
  Tables show an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                                                Page 22 of 27


6.4    ANTENNA R&S HF907 (1 GHZ – 18 GHZ)
                                                                         cable
                                               cable                    loss 3
                                              loss 1                   (switch
                                             (relay +       cable        unit,
                  AF                           cable       loss 2      atten-        cable
                 R&S                          inside      (outside     uator &     loss 4 (to
  Frequency     HF907        Corr.          chamber)     chamber)     pre-amp)     receiver)
     MHz       dB (1/m)       dB                dB           dB            dB          dB
       1000        24,4       -19,4               0,99         0,31       -21,51        0,79
       2000        28,5       -17,4               1,44         0,44       -20,63        1,38
       3000        31,0       -16,1               1,87         0,53       -19,85        1,33
       4000        33,1       -14,7               2,41         0,67       -19,13        1,31
       5000        34,4       -13,7               2,78         0,86       -18,71        1,40
       6000        34,7       -12,7               2,74         0,90       -17,83        1,47
       7000        35,6       -11,0               2,82         0,86       -16,19        1,46

                                                                                      cable
                                                                                     loss 4
                                               cable                                (switch
                                              loss 1        cable        cable        unit,                  used
                  AF                          (relay       loss 2       loss 3      atten-        cable      for
                 R&S                          inside      (inside      (outside     uator &     loss 5 (to   FCC
  Frequency     HF907        Corr.          chamber)     chamber)     chamber)     pre-amp)     receiver)    15.247
     MHz       dB (1/m)       dB                dB           dB           dB            dB          dB
       3000        31,0       -23,4               0,47         1,87         0,53       -27,58        1,33
       4000        33,1       -23,3               0,56         2,41         0,67       -28,23        1,31
       5000        34,4       -21,7               0,61         2,78         0,86       -27,35        1,40
       6000        34,7       -21,2               0,58         2,74         0,90       -26,89        1,47
       7000        35,6       -19,8               0,66         2,82         0,86       -25,58        1,46

                                               cable
                                              loss 1       cable        cable         cable        cable        cable
                  AF                          (relay      loss 2       loss 3        loss 4       loss 5       loss 6
                 R&S                          inside      (High         (pre-       (inside      (outside        (to
  Frequency     HF907        Corr.          chamber)      Pass)        amp)        chamber)     chamber)     receiver)
     MHz       dB (1/m)       dB                dB          dB            dB           dB           dB           dB
       7000        35,6       -57,3               0,56        1,28       -62,72          2,66         0,94         1,46
       8000        36,3       -56,3               0,69        0,71       -61,49          2,84         1,00         1,53
       9000        37,1       -55,3               0,68        0,65       -60,80          3,06         1,09         1,60
      10000        37,5       -56,2               0,70        0,54       -61,91          3,28         1,20         1,67
      11000        37,5       -55,3               0,80        0,61       -61,40          3,43         1,27         1,70
      12000        37,6       -53,7               0,84        0,42       -59,70          3,53         1,26         1,73
      13000        38,2       -53,5               0,83        0,44       -59,81          3,75         1,32         1,83
      14000        39,9       -56,3               0,91        0,53       -63,03          3,91         1,40         1,77
      15000        40,9       -54,1               0,98        0,54       -61,05          4,02         1,44         1,83
      16000        41,3       -54,1               1,23        0,49       -61,51          4,17         1,51         1,85
      17000        42,8       -54,4               1,36        0,76       -62,36          4,34         1,53         2,00
      18000        44,2       -54,7               1,70        0,53       -62,88          4,41         1,55         1,91

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  Linear interpolation will be used for frequencies in between the values in the table.
  Tables show an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                                                  Page 23 of 27


6.5    ANTENNA EMCO 3160-09 (18 GHZ – 26.5 GHZ)
                                               cable       cable       cable        cable       cable
                  AF                          loss 1      loss 2      loss 3       loss 4      loss 5
                EMCO                         (inside       (pre-     (inside      (switch        (to
  Frequency    3160-09       Corr.          chamber)      amp)      chamber)        unit)    receiver)
     MHz       dB (1/m)       dB                dB          dB          dB           dB          dB
      18000        40,2       -23,5               0,72     -35,85         6,20        2,81         2,65
      18500        40,2       -23,2               0,69     -35,71         6,46        2,76         2,59
      19000        40,2       -22,0               0,76     -35,44         6,69        3,15         2,79
      19500        40,3       -21,3               0,74     -35,07         7,04        3,11         2,91
      20000        40,3       -20,3               0,72     -34,49         7,30        3,07         3,05
      20500        40,3       -19,9               0,78     -34,46         7,48        3,12         3,15
      21000        40,3       -19,1               0,87     -34,07         7,61        3,20         3,33
      21500        40,3       -19,1               0,90     -33,96         7,47        3,28         3,19
      22000        40,3       -18,7               0,89     -33,57         7,34        3,35         3,28
      22500        40,4       -19,0               0,87     -33,66         7,06        3,75         2,94
      23000        40,4       -19,5               0,88     -33,75         6,92        3,77         2,70
      23500        40,4       -19,3               0,90     -33,35         6,99        3,52         2,66
      24000        40,4       -19,8               0,88     -33,99         6,88        3,88         2,58
      24500        40,4       -19,5               0,91     -33,89         7,01        3,93         2,51
      25000        40,4       -19,3               0,88     -33,00         6,72        3,96         2,14
      25500        40,5       -20,4               0,89     -34,07         6,90        3,66         2,22
      26000        40,5       -21,3               0,86     -35,11         7,02        3,69         2,28
      26500        40,5       -21,1               0,90     -35,20         7,15        3,91         2,36

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  Linear interpolation will be used for frequencies in between the values in the table.
  Table shows an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                                                Page 24 of 27


6.6    ANTENNA EMCO 3160-10 (18 GHZ – 26.5 GHZ)
                                               cable        cable       cable       cable    distance      dLimit       dused
                  AF                          loss 1       loss 2      loss 3      loss 4      corr.      (meas.       (meas.
                EMCO                         (inside      (outside    (switch        (to     (-20 dB/    distance     distance
  Frequency    3160-10       Corr.          chamber)     chamber)       unit)    receiver)   decade)      (limit)      (used)
     GHz       dB (1/m)       dB                dB           dB          dB          dB         dB           m           m
       26,5        43,4       -11,2                4,4                                          -15,6             3         0,5
       27,0        43,4       -11,2                4,4                                          -15,6             3         0,5
       28,0        43,4       -11,1                4,5                                          -15,6             3         0,5
       29,0        43,5       -11,0                4,6                                          -15,6             3         0,5
       30,0        43,5       -10,9                4,7                                          -15,6             3         0,5
       31,0        43,5       -10,8                4,7                                          -15,6             3         0,5
       32,0        43,5       -10,7                4,8                                          -15,6             3         0,5
       33,0        43,6       -10,7                4,9                                          -15,6             3         0,5
       34,0        43,6       -10,6                5,0                                          -15,6             3         0,5
       35,0        43,6       -10,5                5,1                                          -15,6             3         0,5
       36,0        43,6       -10,4                5,1                                          -15,6             3         0,5
       37,0        43,7       -10,3                5,2                                          -15,6             3         0,5
       38,0        43,7       -10,2                5,3                                          -15,6             3         0,5
       39,0        43,7       -10,2                5,4                                          -15,6             3         0,5
       40,0        43,8       -10,1                5,5                                          -15,6             3         0,5

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  Linear interpolarisation will be used for frequencies in between the values in the table.
  distance correction = -20 * LOG (dLimit/ dused)
  Linear interpolation will be used for frequencies in between the values in the table.
  Table shows an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                                                Page 25 of 27


                                                                                                        layers
                                                                                                        A Bureau Veritas Group Company




7   SETUP DRAWINGS




                    1—4 m height             Anechoic Chamber




                                                                              Equipment
                             RX Antenna                                       under Test




                                                                               Turntable




                                                                                           Turntable
                                                                                           Controller

                                                             Mast                         Digital
                                                                                      Communication
                                                          Controller                      Tester
                                                                                         connected
                                                          Spectrum                     to Equipment
                                                           Analyzer                      under Test


                                   Remark: Depending on the frequency range suitable
                                   antenna types, attenuators or preamplifiers are used,




Setup in the Anechoic chamber. For measurements below 1 GHz the ground was replaced by a
conducting ground plane.




               LILSN                                   Analyzer




                                                       Signaling
               EUT                 1|                         unit
Setup in the shielded room for conducted measurements at AC mains port



TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                                                                          Page 26 of 27


8   MEASUREMENT UNCERTAINTIES


    Test Case                                 Parameter        Uncertainty
    Conducted Emissions at AC mains           Voltage          ± 3.4 dB

    Radiated Emissions                        Field Strength   ± 5.5 dB




9   PHOTO REPORT

Please see separate photo report.




 TEST REPORT REFERENCE: MDE_UBLOX_1603_FCCb                               Page 27 of 27



Document Created: 2019-09-21 08:33:42
Document Modified: 2019-09-21 08:33:42

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC