MDE_UBLOX_1712_FCCc_signed

FCC ID: XPY1EIQ24NN

Test Report

Download: PDF
FCCID_3613799

FCC Measurement/Technical Report on

LARA-R202 UMTS/LTE Module

FCC ID: XPY1EIQ24NN
IC: 8595A-1EIQ24NN
According to: FCC Part 15, Subpart B


Test Report Reference: MDE_UBLOX_1712_FCCc




 Test Laboratory:
 7layers GmbH
 Borsigstrasse 11
 40880 Ratingen
 Germany

 Note:
 The following test results relate only to the devices specified in this document. This report shall not be reproduced in parts
 without the written approval of the test laboratory.

 7layers GmbH                       Geschäftsführer/
 Borsigstraße 11                    Managing Directors:                Registergericht/registered:                          a Bureau Veritas
 40880 Ratingen, Germany            Frank Spiller                      Düsseldorf HRB 75554                                 Group Company
 T +49 (0) 2102 749 0               Bernhard Retka                     USt-Id.-Nr./VAT-No. DE203159652
 F +49 (0) 2102 749 350             Alexandre Norré-Oudard             Steuer-Nr./TAX-No. 147/5869/0385                     www.7layers.com


 Commerzbank AG     Account No. 303 016 000 Bank Code 300 400 00 IBAN DE81 3004 0000 0303 0160 00 Swift Code COBADEFF


Table of Contents

1 Applied Standards and Test Summary                        3
1.1   Applied Standards                                      3
1.2   FCC-IC Correlation Table                               4
1.3   Measurement Summary / Signatures                       4

2 Administrative Data                                       6
2.1   Testing Laboratory                                     6
2.2   Project Data                                           6
2.3   Applicant Data                                         6
2.4   Manufacturer Data                                      6

3 Test object Data                                          7
3.1   General EUT Description                                7
3.2   EUT Main components                                    7
3.3   Ancillary Equipment                                    8
3.4   Auxiliary Equipment                                    8
3.5   EUT Setups                                             8
3.6   Operating Modes                                        9
3.7   Product labelling                                      9

4 Test Results                                            10
4.1   Conducted Emissions at AC mains                      10
4.2   Radiated Emissions                                   13

5 Test Equipment                                          18

6 Antenna Factors, Cable Loss and Sample Calculations     20
6.1   LISN R&S ESH3-Z5 (150 kHz – 30 MHz)                  20
6.2   Antenna R&S HFH2-Z2 (9 kHz – 30 MHz)                 21
6.3   Antenna R&S HL562 (30 MHz – 1 GHz)                   22
6.4   Antenna R&S HF907 (1 GHz – 18 GHz)                   23
6.5   Antenna EMCO 3160-09 (18 GHz – 26.5 GHz)             24
6.6   Antenna EMCO 3160-10 (26.5 GHz – 40 GHz)             25

7 Setup Drawings                                          26

8 Measurement Uncertainties                               28

9 Photo Report                                            28




TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc              Page 2 of 28


1     APPLIED STANDARDS AND TEST SUMMARY

1.1    APPLIED STANDARDS


Applicable FCC Rules

Prepared in accordance with the requirements of FCC Rules and Regulations as listed in 47 CFR
Ch.1 Parts 2 and 15 (10-1-15 Edition). The following subparts are applicable to the results in
this test report.


Part 2, Subpart J - Equipment Authorization Procedures, Certification

Part 15, Subpart B – Unintentional Radiators

§ 15.107   Conducted limits

§ 15.109   Radiated emission limits; general requirements


Note:
ANSI C63.4–2014 is applied.




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                        Page 3 of 28


Summary Test Results:

The EUT complied with all performed tests as listed in chapter 1.3 Measurement
Summary / Signatures.


1.2   FCC-IC CORRELATION TABLE


Correlation of measurement requirements for
               Information Technology Equipment (ITE)
                                from
                             FCC and IC

 Measurement                   FCC reference               IC reference
 Conducted Emissions           §15.107                     ICES-003 Issue 6: 6.1
 (AC Power Line)
 Radiated Spurious Emissions   §15.109                     ICES-003 Issue 6: 6.2


Remarks:

1. FCC Part 15 subpart B, ICES 003 and CISPR 22 contain different definitions of Class A and
   Class B limits, i.e. which class is applicable to which kind of EUT.
   ICES 003 and CISPR 22 distinguish between the location where the EUT is intended to
   operate whilst FCC refers to the method of commercial distribution (distributive trades).
2. The correct assignment of the appropriate class to the concrete EUT is not scope of this
   test report!
3. A radio apparatus that is specifically subject to an Industry Canada Radio Standard
   Specification (RSS) and which contains an ITE is not subject to ICES-003 provided the ITE
   is used only to enable operation of the radio apparatus and the ITE does not control
   additional functions or capabilities.
4. ISM (Industrial, Scientific or Medical) radio frequency generators, though they may contain
   ITE, are excluded from the definition of ITE and are not subject to ICES-003. They are
   instead subject to the Interference-Causing Equipment Standard ICES-001, which
   specifically addresses ISM radio frequency generators.




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                        Page 4 of 28


                                                                           layers
                                                                           3/     A Bureau Veritas Group Company




1.3   MEASUREMENT SUMMARY / SIGNATURES


47 CFR CHAPTER I FCC PART 15 Subpart B             § 15.107
Conducted Emissions at AC mains
The measurement was performed according to ANSI C63.4                            Final Result

OP—Mode                                                         Setup            FCC             IC
AC mains connection, Test setup
via connected computer device, computer peripheric              15b_Setup_R      Passed          Passed
                                                                202

47 CFR CHAPTER I FCC PART 15 Subpart B             §15.109
Radiated Emissions
The measurement was performed according to ANSI C63.4                            Final Result

OP—Mode                                                        Setup             FCC             IC
AC mains connection, Measurement range, Test setup
via connected computer device, 1 GHz — 10 GHz, computer         15b_Setup_R      Passed          Passed
peripheric                                                      202
via connected computer device, 30 MHz — 1 GHz, computer         15b_Setup_R      Passed          Passed
peripheric                                                      202




                                                      Z    //\
        (responsible for accreditation scope)        7/   (résponsible for testing and report)
          Dipl.—Ing. Bernhard Retka                                Patrick Lomax




TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                                       Page 5 of 28


2     ADMINISTRATIVE DATA

2.1    TESTING LABORATORY

Company Name:                            7layers GmbH

Address:                                 Borsigstr. 11
                                         40880 Ratingen
                                         Germany

This facility has been fully described in a report submitted to the FCC and accepted under
the registration number 96716.

This facility has been fully described in a report submitted to the IC and accepted under the
registration number: Site# 3699A-1.

The test facility is also accredited by the following accreditation organisation:

Laboratory accreditation no:             DAkkS D-PL-12140-01-00


Responsible for accreditation scope:     Dipl.-Ing. Bernhard Retka

Report Template Version:                 2017-07-14


2.2    PROJECT DATA

Responsible for testing and report:      Patrick Lomax

Employees who performed the tests:       documented internally at 7Layers

Date of Report:                          2017-10-06

Testing Period:                          2017-08-16 to 2017-08-17



2.3    APPLICANT DATA

Company Name:                            u-blox AG

Address:                                 Zürcherstrasse 68
                                         CH-8800 Thalwil
                                         Switzerland

Contact Person:                          Mr. Giulio Comar


2.4    MANUFACTURER DATA

Company Name:                            See applicant data




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                          Page 6 of 28


3     TEST OBJECT DATA

3.1     GENERAL EUT DESCRIPTION

Kind of Device           UMTS / LTE Data Module
product description
Product name             LARA-R202
Type                     LARA-R202

Declared EUT data by the supplier
Power Supply Type        DC
Comment                  DC Power via AC/DC adapter
Nominal Voltage /        3.8 V DC
Frequency
Test Voltage /           input: 120 V / 60 Hz AC
Frequency                output: 3.8 V DC
Highest internal         2480 MHz
frequency
General Description      UMTS / LTE Data module
Ports                    USB
                         RS232
Special software used    Terminal program (e.g. Putty)
for testing

The main components of the EUT are listed and described in chapter 3.2 EUT Main
components.


3.2     EUT MAIN COMPONENTS

Sample Name              Sample Code                         Description
AA01                     AF02                                Standard sample
  Sample Parameter                                       Value
Serial No.               357649070014249
HW Version               273A01
SW Version               30.39
Comment




TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                     Page 7 of 28


NOTE:The short description is used to simplify the identification of the EUT in this test report.


3.3     ANCILLARY EQUIPMENT

For the purposes of this test report, ancillary equipment is defined as equipment which is used
in conjunction with the EUT to provide operational and control features to the EUT. It is
necessary to configure the system in a typical fashion, as a customer would normally use it.
But nevertheless Ancillary Equipment can influence the test results.

Device                            Details                                                Description
                                  (Manufacturer, Type Model, OUT
                                  Code)
AC/DC Adapter                     UNIFIVE, UUX324-1215, G05-0122279                      ANC1

DC Power Supply                   PeakTech, 6005D, 081062045                             ANC2


3.4     AUXILIARY EQUIPMENT

For the purposes of this test report, auxiliary equipment is defined as equipment which is used
temporarily to enable operational and control features especially used for the tests of the EUT
which is not used during normal operation or equipment that is used during the tests in
combination with the EUT but is not subject of this test report. It is necessary to configure the
system in a typical fashion, as a customer would normally use it.
But nevertheless Auxiliary Equipment can influence the test results.

Device                             Details                                  Description
                                   (Manufacturer, HW, SW, S/N)
Laptop                            Fujitsu Lifebook E series E782, 2011.11, -
                                  DSCM004672

AC/DC Adapt. Laptop               Fujitsu Ltd. SEB100P2-19.0, CA010007- -
                                  0920
Monitor                           LG Flatron L1730BSNHN-ANE             -

Mouse                             Logitech M-BB48                                        -

Keyboard                          CHERRY RS 6000 USB ON                                  -




3.5     EUT SETUPS

This chapter describes the combination of EUTs and equipment used for testing. The rationale
for selecting the EUTs, ancillary and auxiliary equipment and interconnecting cables, is to test
a representative configuration meeting the requirements of the referenced standards.

   Setup         Combination of EUTs                             Description and Rationale
 15b_Setup              AF01                                           -
   _R202




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                                            Page 8 of 28


3.6       OPERATING MODES
This chapter describes the operating modes of the EUTs used for testing.

3.6.1 TEST CHANNELS

         UMTS FDD2 channel 9400 (1880MHz) for conducted emissions
         eFDD2 idle mode for radiated emissions

For all measurements USB & RS232 data traffic was established




3.7       PRODUCT LABELLING

3.7.1 FCC ID LABEL
Please refer to the documentation of the applicant.


3.7.2 LOCATION OF THE LABEL ON THE EUT
Please refer to the documentation of the applicant.




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                Page 9 of 28


4     TEST RESULTS



4.1    CONDUCTED EMISSIONS AT AC MAINS

Standard      FCC Part 15 Subpart B

The test was performed according to:
ANSI C63.4

4.1.1 TEST DESCRIPTION

The test set-up was made in accordance to the general provisions of ANSI C 63.4
The Equipment Under Test (EUT) was setup in a shielded room to perform the conducted
emissions measurements in a typical installation configuration. The EUT was powered from
50µH || 50 Ohm Line Impedance Stabilization Network (LISN). The LISN’s unused connections
were terminated with 50 Ohm loads.

The measurement procedure consists of two steps. It is implemented into the EMI test
software EMC-32 from R&S.

Step 1: Preliminary scan
Intention of this step is, to determine the conducted EMI-profile of the EUT.
EMI receiver settings:
- Detector: Peak – Maxhold & Average
- Frequency range: 150 kHz – 30 MHz
- Frequency steps: 2.5 kHz
- IF–Bandwidth: 9 kHz
- Measuring time / Frequency step: 100 ms (FFT-based)
- Measurement on phase + neutral lines of the power cords

On basis of this preliminary scan the highest amplitudes and the corresponding frequencies
relative to the limit are identified. Emissions above the limit and emissions which are in the 10
dB range below the limit are considered.

Step 2: Final measurement
Intention of this step is, to determine the highest emissions with the settings defined in the
test specification for the frequencies identified in step 1.
EMI receiver settings:
- Detector: Quasi-Peak
- IF Bandwidth: 9 kHz
- Measuring time: 1 s / frequency

At each frequency determined in step 1, four measurements are performed in the following
combinations:
1) Neutral lead - reference ground (PE grounded)
2) Phase lead - reference ground (PE grounded)
3) Neutral lead - reference ground (PE floating)
4) Phase lead - reference ground (PE floating)

The highest value is reported.




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                          Page 10 of 28


4.1.2 TEST REQUIREMENTS / LIMITS

FCC Part 15, Subpart B, §15.107

Class B:
 Frequency (MHz)       QP Limits (dBµV)      AV Limits (dBµV)
 0.15 – 0.5            66 - 56               56 - 46
 0.5 - 5               56                    46
 5 - 30                60                    50


Class A:
 Frequency (MHz)       QP Limits (dBµV)      AV Limits (dBµV)
 0.15 – 0.5            79                    66
 0.5 - 30              73                    60




4.1.3 TEST PROTOCOL

 Temperature:           26 °C
 Air Pressure:          1017 hPa
 Humidity:              40 %
 Computer Peripheral
 Power line    PE       Frequency [MHz]     Level [dBµV]       Detector   Limit [dBµV]   Margin [dB]
 L1            GND      0                   38                 QP         57             18
 N             FLO      0                   29                 AV         47             18


Remark: Please see next sub-clause for the measurement plot.




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                                       Page 11 of 28


4.1.4 MEASUREMENT PLOT (SHOWING THE HIGHEST VALUE, “WORST CASE”)



                       80



                       70


                                                                                                   Limit_15_107_QP_ClassB
                       60


                                                                                                   Limit_15_107_AV_ClassB
                       50
       Level in dBµV




                       40



                       30



                       20



                       10



                       0
                       150k          300 400 500         800 1M         2M     3M 4M 5M 6          8 10M          20M    30M
                                                                   Frequency in Hz


Final_Result
   Frequency                  QuasiPeak     CAverage      Limit    Margin    Meas.    Bandwidth      Line    PE     Corr.
     (MHz)                     (dBµV)        (dBµV)      (dBµV)     (dB)     Time       (kHz)                       (dB)
                                                                             (ms)
       0.442500                    38.40           ---     57.02     18.62   1000.0        9.000    L1      GND         10.1
       0.447000                       ---       28.59      46.93     18.34   1000.0        9.000    N       FLO         10.1



4.1.5 TEST EQUIPMENT USED
   -     Conducted Emissions FCC




TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                                                                     Page 12 of 28


4.2   RADIATED EMISSIONS

Standard      FCC Part 15 Subpart B

The test was performed according to:
ANSI C63.4

4.2.1 TEST DESCRIPTION

The test set-up was made in accordance to the general provisions of ANSI C63.4 in a typical
installation configuration. The Equipment Under Test (EUT) was set up on a non-conductive
table 1.0 x 2.0 m² in the semi-anechoic chamber. The influence of the EUT support table that
is used was evaluated. For the measurement above 1 GHz an absorber field with 30 cm
pyramidical absorber is placed between EUT table and antenna (required to fulfil the CISPR
16.1.4 S-VSWR criteria).
The measurement procedure is implemented into the EMI test software EMC32 from R&S.

1. Measurement above 30 MHz and up to 1 GHz

Step 1: Preliminary scan
This is a preliminary test to identify the highest amplitudes relative to the limit.
Settings for step 1:
- Antenna distance: 3 m
- Detector: Peak-Maxhold / Quasipeak (FFT-based)
- Frequency range: 30 – 1000 MHz
- Frequency steps: 30 kHz
- IF–Bandwidth: 120 kHz
- Measuring time / Frequency step: 100 ms
- Turntable angle range: –180° to 90°
- Turntable step size: 90°
- Height variation range: 1 – 3 m
- Height variation step size: 2 m
- Polarisation: Horizontal + Vertical
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.

Step 2: Adjustment measurement
In this step the accuracy of the turntable azimuth and antenna height will be improved. This is
necessary to find out the maximum value of every frequency.
For each frequency, which was determined the turntable azimuth and antenna height will be
adjusted. The turntable azimuth will slowly vary by ± 45° around this value. During this action,
the value of emission is continuously measured. The turntable azimuth at the highest emission
will be recorded and adjusted. In this position, the antenna height will also slowly vary by ±
100 cm around the antenna height determined. During this action, the value of emission is
also continuously measured. The antenna height of the highest emission will also be recorded
and adjusted.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 100 ms
- Turntable angle range: ± 45 ° around the determined value
- Height variation range: ± 100 cm around the determined value

 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                          Page 13 of 28


- Antenna Polarisation: max. value determined in step 1

Step 3: Final measurement with QP detector
With the settings determined in step 3, the final measurement will be performed:
EMI receiver settings for step 4:
- Detector: Quasi-Peak
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 120 kHz
- Measuring time: 1 s

2. Measurement above 1 GHz

Step 1: Preliminary scan
This is a preliminary test to identify the highest amplitudes relative to the limit.
Settings for step 1:
- Antenna distance: 3 m
- Detector: Peak-Maxhold / Average (up to 7 GHz FFT-based)
- Frequency range: 30 – 1000 MHz
- Frequency steps: 250 kHz
- IF–Bandwidth: 1 MHz
- Measuring time / Frequency step: 100 ms (up to 7 GHz) / 500µs (above 7 GHz
- Turntable angle range: –180° to 45°
- Turntable step size: 45°
- Height variation range: 1 – 3.6 m (due to the small antenna lobe, a tilt-mast is used)
- Height variation step size: 0.9 m
- Polarisation: Horizontal + Vertical
Intention of this step is, to determine the radiated EMI-profile of the EUT. Afterwards the
relevant emissions for the final measurement are identified.

Step 2: Adjustment measurement
In this step the accuracy of the turntable azimuth and antenna height will be improved. This is
necessary to find out the maximum value of every frequency.
For each frequency, which was determined the turntable azimuth and antenna height will be
adjusted. The turntable azimuth will slowly vary by ± 22.5° around this value. During this
action, the value of emission is continuously measured. The turntable azimuth at the highest
emission will be recorded and adjusted. In this position, the antenna height will also slowly
vary by ± 45 cm around the antenna height determined. During this action, the value of
emission is also continuously measured. The antenna height of the highest emission will also
be recorded and adjusted.
- Detector: Peak – Maxhold
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 1 MHz
- Measuring time: 100 ms
- Turntable angle range: ± 45 ° around the determined value
- Height variation range: ± 45 cm around the determined value
- Antenna Polarisation: max. value determined in step 1

Step 3: Final measurement with Max-Peak / CISPR-Average detector
With the settings determined in step 3, the final measurement will be performed:
EMI receiver settings for step 4:
- Detector: Max-Peak / CISPR-Average
- Measured frequencies: in step 1 determined frequencies
- IF – Bandwidth: 1 MHz
- Measuring time: 200 ms



 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                          Page 14 of 28


After each measurement, a report will be generated which contains a diagram with the results
of the preliminary scan and a table with the frequencies, values and polarisation of the results
of the final measurement.



4.2.2 TEST REQUIREMENTS / LIMITS

FCC Part 15, Subpart B, §15.109, Radiated Emission Limits

Class B:
                                             Measurement
 Frequency (MHz)     Limit (µV/m)                               Limits (dBµV/m)
                                             distance (m)
 30 – 88             100@3m                  3                  40.0@3m
 88 – 216            150@3m                  3                  43.5@3m
 216 – 960           200@3m                  3                  46.0@3m
 960 - 26000         500@3m                  3                  54.0@3m
 26000 - 40000       500@3m                  1                  54.0@3m


Class A:
                                             Measurement
 Frequency (MHz)     Limit (µV/m)                               Limits (dBµV/m)
                                             distance (m)
 30 – 88             90@10m                  3                  39.1@10m
 88 – 216            150@10m                 3                  43.5@10m
 216 – 960           210@10m                 3                  46.4@10m
 960 - 26000         300@10m                 3                  49.5@10m
 26000 - 40000       300@10m                 1                  49.5@10m




The measured values for Class A and for Class B (> 26 GHz) measurements are corrected with
an inverse linear distance extrapolation factor (20 dB/decade).

§15.35(b) ..., there is also a limit on the radio frequency emissions, as measured using
instrumentation with a peak detector function, corresponding to 20 dB above the maximum
permitted average limit....

Used conversion factor: Limit (dBµV/m) = 20 log (Limit (µV/m)/1µV/m)



4.2.3 TEST PROTOCOL

 Ambient temperature:     26 °C
 Air Pressure:            1014 hPa
 Humidity:                46 %
 Computer Peripheral
 Setup
 Spurious Freq.           Spurious Level           Detector    RBW         Limit      Margin to Limit
 [MHz]                    [dBµV/m]                             [kHz]       [dBµV/m]   [dB]
 30.3                     32.8                     QP          120         40.0       7.2
 39.5                     35.3                     QP          120         40.0       4.7
 207.7                    33.0                     QP          120         43.5       10.5
 350.2                    29.1                     QP          120         46.0       16.9
 487.5                    28.2                     QP          120         46.0       17.8
 661.9                    32.3                     QP          120         46.0       13.7


Remark: Please see next sub-clause for the measurement plot.



 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                               Page 15 of 28


4.2.4 MEASUREMENT PLOT (SHOWING THE HIGHEST VALUE, “WORST CASE”)


                       60

                       55                                       FCC_15.109_ClassB@3m_30MHz-1GHz

                       50

                       45

                       40

                       35
     Level in dBµV/m




                       30

                       25

                       20

                       15

                       10

                       5

                       0

                       -5


                        30M   50   60   80 100M           200       300   400   500    800   1G
                                                  Frequency in Hz




TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                                    Page 16 of 28


                            80
                                                                                    FCC_15.109_ClassB@3m_1GHz-18GHz_Peak

                            70



                            60
                                                                                       FCC_15.109_ClassB@3m_1GHz-18GHz_AV

                            50
          Level in dBµV/m




                            40



                            30



                            20


                            10



                            0
                             1G                    2G              3G        4G       5G       6            8             10G         18G
                                                                        Frequency in Hz



Final_Result
   Frequency                      QuasiPeak     Limit    Margin     Meas.         Bandwidth        Height           Pol     Azimu
     (MHz)                        (dBµV/m)     (dBµV/     (dB)      Time            (kHz)           (cm)                      th
                                                 m)                 (ms)                                                    (deg)
        30.300000                      32.83     40.00      7.17    1000.0           120.000        110.0       V             63.0
        39.510000                      35.30     40.00      4.70    1000.0           120.000        106.0       V            107.0
       207.720000                      32.96     43.50     10.54    1000.0           120.000        182.0       H           -118.0
       350.160000                      29.14     46.00     16.86    1000.0           120.000        105.0       H             12.0
       487.500000                      28.16     46.00     17.84    1000.0           120.000        119.0       V               8.0
       661.920000                      32.33     46.00     13.67    1000.0           120.000        103.0       V           -133.0




4.2.5 TEST EQUIPMENT USED
   -        Radiated Emissions




TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                                                                              Page 17 of 28


5     TEST EQUIPMENT
1        Conducted Emissions FCC
         Conducted Emissions power line for FCC standards

Ref.No. Device Name Description               Manufacturer Serial Number            Last     Calibration
                                                                                 Calibration     Due
1.1      ESH 3-Z5 "AUX" Two-Line V-   Rohde & Schwarz            828304/029     2017-05      2019-05
         S/N 828304/029 Network
1.2      Shielded Room Shielded Room Frankonia                   -
         02             for conducted
                        testing, 12qm
1.3      ESH 3-Z5 "EUT" Two-Line V-   Rohde & Schwarz            829996/002     2017-05      2019-05
         S/N 829996/002 Network

2        Radiated Emissions
         Lab to perform radiated emission tests

Ref.No. Device Name Description               Manufacturer Serial Number            Last     Calibration
                                                                                 Calibration     Due
2.1      Opus10 TPR        ThermoAirpres    Lufft Mess- und   13936             2017-04      2019-04
         (8253.00)         sure             Regeltechnik GmbH
                           Datalogger 13
                           (Environ)
2.2      Anechoic          10.58 x 6.38 x   Frankonia            none           2016-05      2019-05
         Chamber           6.00 m³
2.3      HL 562            Ultralog new     Rohde & Schwarz      830547/003     2015-06      2018-06
                           biconicals
2.4      5HC2700/12750     High Pass        Trilithic            9942012
         -1.5-KK           Filter
2.5      Fully Anechoic    8.80m x          Albatross Projects   P26971-647-001- 2015-06     2018-06
         Room              4.60m x                               PRB
                           4.05m (l x w x
                           h)
2.6      Fluke 177         Digital          Fluke Europe B.V.    86670383       2016-02      2018-02
                           Multimeter 03
                           (Multimeter)
2.7      JS4-18002600-     Broadband        Miteq                849785
         32-5P             Amplifier 18
                           GHz - 26 GHz
2.8      WHKX 7.0/18G-     High Pass        Wainwright           09
         8SS               Filter
2.9      4HC1600/12750     High Pass        Trilithic            9942011
         -1.5-KK           Filter
2.10     Chroma 6404       AC Power         Chroma ATE INC.      64040001304
                           Source
2.11     JS4-00102600-     Broadband        Miteq                619368
         42-5A             Amplifier 30
                           MHz - 26 GHz
2.12     HL 562 Ultralog   Log.-per.        Rohde & Schwarz      100609         2016-04      2019-04
                           Antenna
2.13     3160-10           Standard Gain    EMCO Elektronic      00086675
                           / Pyramidal      GmbH
                           Horn Antenna
                           40 GHz
2.14     5HC3500/18000     High Pass        Trilithic            200035008
         -1.2-KK           Filter
2.15     HFH2-Z2           Loop Antenna     Rohde & Schwarz      829324/006     2014-11      2017-11



 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                                Page 18 of 28


Ref.No. Device Name Description         Manufacturer Serial Number           Last     Calibration
                                                                          Calibration     Due
2.16    Opus10 THI    ThermoHygro Lufft Mess- und        12482            2017-03      2019-03
        (8152.00)     Datalogger 12 Regeltechnik GmbH
                      (Environ)
2.17    JS4-00101800- Broadband      Miteq               896037
        35-5P         Amplifier 30
                      MHz - 18 GHz
2.18    AS 620 P      Antenna mast HD GmbH               620/37
2.19    Tilt device   Antrieb TD1.5- Maturo GmbH         TD1.5-
        Maturo        10kg                               10kg/024/37907
        (Rohacell)                                       09
2.20    AM 4.0        Antenna mast Maturo GmbH           AM4.0/180/1192
                                                         0513
2.21    HF 907          Double-ridged Rohde & Schwarz    102444         2015-05        2018-05
                        horn


The calibration interval is the time interval between “Last Calibration” and “Calibration Due”




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                          Page 19 of 28


6     ANTENNA FACTORS, CABLE LOSS AND SAMPLE CALCULATIONS
This chapter contains the antenna factors with their corresponding path loss of the used
measurement path for all antennas as well as the insertion loss of the LISN.



6.1      LISN R&S ESH3-Z5 (150 KHZ – 30 MHZ)
                                                           cable
                                                LISN        loss
                                             insertion   (incl. 10
                                                loss         dB
                                               ESH3-      atten-
    Frequency                 Corr.              Z5       uator)
       MHz                     dB                dB          dB
         0.15                   10.1               0.1        10.0
            5                   10.3               0.1        10.2
            7                   10.5               0.2        10.3
           10                   10.5               0.2        10.3
           12                   10.7               0.3        10.4
           14                   10.7               0.3        10.4
           16                   10.8               0.4        10.4
           18                   10.9               0.4        10.5
           20                   10.9               0.4        10.5
           22                   11.1               0.5        10.6
           24                   11.1               0.5        10.6
           26                   11.2               0.5        10.7
           28                   11.2               0.5        10.7
           30                   11.3               0.5        10.8

Sample calculation

    ULISN (dB µV) = U (dB µV) + Corr. (dB)
    U = Receiver reading
    LISN Insertion loss = Voltage Division Factor of LISN
    Corr. = sum of single correction factors of used LISN, cables, switch units (if used)
    Linear interpolation will be used for frequencies in between the values in the table.




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                                 Page 20 of 28


6.2    ANTENNA R&S HFH2-Z2 (9 KHZ – 30 MHZ)
                                               cable        cable       cable        cable     distance     dLimit      dused
                                              loss 1       loss 2      loss 3       loss 4       corr.     (meas.      (meas.
                  AF                         (inside      (outside    (switch         (to      (-40 dB/   distance    distance
  Frequency    HFH-Z2)       Corr.          chamber)     chamber)       unit)     receiver)    decade)     (limit)     (used)
     MHz       dB (1/m)       dB                dB           dB          dB           dB          dB          m          m
      0.009      20.50        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.01      20.45        -79.6                0.1          0.1         0.1          0.1        -80        300            3
      0.015      20.37        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.02      20.36        -79.6                0.1          0.1         0.1          0.1        -80        300            3
      0.025      20.38        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.03      20.32        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.05      20.35        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.08      20.30        -79.6                0.1          0.1         0.1          0.1        -80        300            3
        0.1      20.20        -79.6                0.1          0.1         0.1          0.1        -80        300            3
        0.2      20.17        -79.6                0.1          0.1         0.1          0.1        -80        300            3
        0.3      20.14        -79.6                0.1          0.1         0.1          0.1        -80        300            3
       0.49      20.12        -79.6                0.1          0.1         0.1          0.1        -80        300            3
   0.490001      20.12        -39.6                0.1          0.1         0.1          0.1        -40          30           3
        0.5      20.11        -39.6                0.1          0.1         0.1          0.1        -40          30           3
        0.8      20.10        -39.6                0.1          0.1         0.1          0.1        -40          30           3
          1      20.09        -39.6                0.1          0.1         0.1          0.1        -40          30           3
          2      20.08        -39.6                0.1          0.1         0.1          0.1        -40          30           3
          3      20.06        -39.6                0.1          0.1         0.1          0.1        -40          30           3
          4      20.05        -39.5                0.2          0.1         0.1          0.1        -40          30           3
          5      20.05        -39.5                0.2          0.1         0.1          0.1        -40          30           3
          6      20.02        -39.5                0.2          0.1         0.1          0.1        -40          30           3
          8      19.95        -39.5                0.2          0.1         0.1          0.1        -40          30           3
         10      19.83        -39.4                0.2          0.1         0.2          0.1        -40          30           3
         12      19.71        -39.4                0.2          0.1         0.2          0.1        -40          30           3
         14      19.54        -39.4                0.2          0.1         0.2          0.1        -40          30           3
         16      19.53        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         18      19.50        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         20      19.57        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         22      19.61        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         24      19.61        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         26      19.54        -39.3                0.3          0.1         0.2          0.1        -40          30           3
         28      19.46        -39.2                0.3          0.1         0.3          0.1        -40          30           3
         30      19.73        -39.1                0.4          0.1         0.3          0.1        -40          30           3

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  distance correction = -40 * LOG (dLimit/ dused)
  Linear interpolation will be used for frequencies in between the values in the table.
  Table shows an extract of values




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                                                 Page 21 of 28


6.3    ANTENNA R&S HL562 (30 MHZ – 1 GHZ)
(dLimit = 3 m)
                                               cable        cable       cable       cable     distance     dLimit       dused
                    AF                        loss 1       loss 2      loss 3      loss 4       corr.     (meas.       (meas.
                   R&S                       (inside      (outside    (switch        (to      (-20 dB/   distance     distance
  Frequency       HL562      Corr.          chamber)     chamber)       unit)    receiver)    decade)     (limit)      (used)
     MHz         dB (1/m)     dB                dB           dB          dB          dB          dB          m           m
         30          18.6       0.6               0.29         0.04       0.23         0.02        0.0            3           3
         50           6.0       0.9               0.39         0.09       0.32         0.08        0.0            3           3
        100           9.7       1.2               0.56         0.14       0.47         0.08        0.0            3           3
        150           7.9       1.6               0.73         0.20       0.59         0.12        0.0            3           3
        200           7.6       1.9               0.84         0.21       0.70         0.11        0.0            3           3
        250           9.5       2.1               0.98         0.24       0.80         0.13        0.0            3           3
        300          11.0       2.3               1.04         0.26       0.89         0.15        0.0            3           3
        350          12.4       2.6               1.18         0.31       0.96         0.13        0.0            3           3
        400          13.6       2.9               1.28         0.35       1.03         0.19        0.0            3           3
        450          14.7       3.1               1.39         0.38       1.11         0.22        0.0            3           3
        500          15.6       3.2               1.44         0.39       1.20         0.19        0.0            3           3
        550          16.3       3.5               1.55         0.46       1.24         0.23        0.0            3           3
        600          17.2       3.5               1.59         0.43       1.29         0.23        0.0            3           3
        650          18.1       3.6               1.67         0.34       1.35         0.22        0.0            3           3
        700          18.5       3.6               1.67         0.42       1.41         0.15        0.0            3           3
        750          19.1       4.1               1.87         0.54       1.46         0.25        0.0            3           3
        800          19.6       4.1               1.90         0.46       1.51         0.25        0.0            3           3
        850          20.1       4.4               1.99         0.60       1.56         0.27        0.0            3           3
        900          20.8       4.7               2.14         0.60       1.63         0.29        0.0            3           3
        950          21.1       4.8               2.22         0.60       1.66         0.33        0.0            3           3
       1000          21.6       4.9               2.23         0.61       1.71         0.30        0.0            3           3


(dLimit = 10 m)
           30       18.6        -9.9             0.29         0.04        0.23        0.02       -10.5          10           3
           50        6.0        -9.6             0.39         0.09        0.32        0.08       -10.5          10           3
          100        9.7        -9.2             0.56         0.14        0.47        0.08       -10.5          10           3
          150        7.9        -8.8             0.73         0.20        0.59        0.12       -10.5          10           3
          200        7.6        -8.6             0.84         0.21        0.70        0.11       -10.5          10           3
          250        9.5        -8.3             0.98         0.24        0.80        0.13       -10.5          10           3
          300       11.0        -8.1             1.04         0.26        0.89        0.15       -10.5          10           3
          350       12.4        -7.9             1.18         0.31        0.96        0.13       -10.5          10           3
          400       13.6        -7.6             1.28         0.35        1.03        0.19       -10.5          10           3
          450       14.7        -7.4             1.39         0.38        1.11        0.22       -10.5          10           3
          500       15.6        -7.2             1.44         0.39        1.20        0.19       -10.5          10           3
          550       16.3        -7.0             1.55         0.46        1.24        0.23       -10.5          10           3
          600       17.2        -6.9             1.59         0.43        1.29        0.23       -10.5          10           3
          650       18.1        -6.9             1.67         0.34        1.35        0.22       -10.5          10           3
          700       18.5        -6.8             1.67         0.42        1.41        0.15       -10.5          10           3
          750       19.1        -6.3             1.87         0.54        1.46        0.25       -10.5          10           3
          800       19.6        -6.3             1.90         0.46        1.51        0.25       -10.5          10           3
          850       20.1        -6.0             1.99         0.60        1.56        0.27       -10.5          10           3
          900       20.8        -5.8             2.14         0.60        1.63        0.29       -10.5          10           3
          950       21.1        -5.6             2.22         0.60        1.66        0.33       -10.5          10           3
         1000       21.6        -5.6             2.23         0.61        1.71        0.30       -10.5          10           3

Sample calculation
  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  distance correction = -20 * LOG (dLimit/ dused)
  Linear interpolation will be used for frequencies in between the values in the table.
  Tables show an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                                                Page 22 of 28


6.4    ANTENNA R&S HF907 (1 GHZ – 18 GHZ)
                                                                         cable
                                               cable                    loss 3
                                              loss 1                   (switch
                                             (relay +       cable        unit,
                  AF                           cable       loss 2      atten-        cable
                 R&S                          inside      (outside     uator &     loss 4 (to
  Frequency     HF907        Corr.          chamber)     chamber)     pre-amp)     receiver)
     MHz       dB (1/m)       dB                dB           dB            dB          dB
       1000        24.4       -19.4               0.99         0.31       -21.51        0.79
       2000        28.5       -17.4               1.44         0.44       -20.63        1.38
       3000        31.0       -16.1               1.87         0.53       -19.85        1.33
       4000        33.1       -14.7               2.41         0.67       -19.13        1.31
       5000        34.4       -13.7               2.78         0.86       -18.71        1.40
       6000        34.7       -12.7               2.74         0.90       -17.83        1.47
       7000        35.6       -11.0               2.82         0.86       -16.19        1.46

                                                                                      cable
                                                                                     loss 4
                                               cable                                (switch
                                              loss 1        cable        cable        unit,                  used
                  AF                          (relay       loss 2       loss 3      atten-        cable      for
                 R&S                          inside      (inside      (outside     uator &     loss 5 (to   FCC
  Frequency     HF907        Corr.          chamber)     chamber)     chamber)     pre-amp)     receiver)    15.247
     MHz       dB (1/m)       dB                dB           dB           dB            dB          dB
       3000        31.0       -23.4               0.47         1.87         0.53       -27.58        1.33
       4000        33.1       -23.3               0.56         2.41         0.67       -28.23        1.31
       5000        34.4       -21.7               0.61         2.78         0.86       -27.35        1.40
       6000        34.7       -21.2               0.58         2.74         0.90       -26.89        1.47
       7000        35.6       -19.8               0.66         2.82         0.86       -25.58        1.46

                                               cable
                                              loss 1       cable        cable         cable        cable        cable
                  AF                          (relay      loss 2       loss 3        loss 4       loss 5       loss 6
                 R&S                          inside      (High         (pre-       (inside      (outside        (to
  Frequency     HF907        Corr.          chamber)      Pass)        amp)        chamber)     chamber)     receiver)
     MHz       dB (1/m)       dB                dB          dB            dB           dB           dB           dB
       7000        35.6       -57.3               0.56        1.28       -62.72          2.66         0.94         1.46
       8000        36.3       -56.3               0.69        0.71       -61.49          2.84         1.00         1.53
       9000        37.1       -55.3               0.68        0.65       -60.80          3.06         1.09         1.60
      10000        37.5       -56.2               0.70        0.54       -61.91          3.28         1.20         1.67
      11000        37.5       -55.3               0.80        0.61       -61.40          3.43         1.27         1.70
      12000        37.6       -53.7               0.84        0.42       -59.70          3.53         1.26         1.73
      13000        38.2       -53.5               0.83        0.44       -59.81          3.75         1.32         1.83
      14000        39.9       -56.3               0.91        0.53       -63.03          3.91         1.40         1.77
      15000        40.9       -54.1               0.98        0.54       -61.05          4.02         1.44         1.83
      16000        41.3       -54.1               1.23        0.49       -61.51          4.17         1.51         1.85
      17000        42.8       -54.4               1.36        0.76       -62.36          4.34         1.53         2.00
      18000        44.2       -54.7               1.70        0.53       -62.88          4.41         1.55         1.91

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  Linear interpolation will be used for frequencies in between the values in the table.
  Tables show an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                                                  Page 23 of 28


6.5    ANTENNA EMCO 3160-09 (18 GHZ – 26.5 GHZ)
                                               cable       cable       cable        cable       cable
                  AF                          loss 1      loss 2      loss 3       loss 4      loss 5
                EMCO                         (inside       (pre-     (inside      (switch        (to
  Frequency    3160-09       Corr.          chamber)      amp)      chamber)        unit)    receiver)
     MHz       dB (1/m)       dB                dB          dB          dB           dB          dB
      18000        40.2       -23.5               0.72     -35.85         6.20        2.81         2.65
      18500        40.2       -23.2               0.69     -35.71         6.46        2.76         2.59
      19000        40.2       -22.0               0.76     -35.44         6.69        3.15         2.79
      19500        40.3       -21.3               0.74     -35.07         7.04        3.11         2.91
      20000        40.3       -20.3               0.72     -34.49         7.30        3.07         3.05
      20500        40.3       -19.9               0.78     -34.46         7.48        3.12         3.15
      21000        40.3       -19.1               0.87     -34.07         7.61        3.20         3.33
      21500        40.3       -19.1               0.90     -33.96         7.47        3.28         3.19
      22000        40.3       -18.7               0.89     -33.57         7.34        3.35         3.28
      22500        40.4       -19.0               0.87     -33.66         7.06        3.75         2.94
      23000        40.4       -19.5               0.88     -33.75         6.92        3.77         2.70
      23500        40.4       -19.3               0.90     -33.35         6.99        3.52         2.66
      24000        40.4       -19.8               0.88     -33.99         6.88        3.88         2.58
      24500        40.4       -19.5               0.91     -33.89         7.01        3.93         2.51
      25000        40.4       -19.3               0.88     -33.00         6.72        3.96         2.14
      25500        40.5       -20.4               0.89     -34.07         6.90        3.66         2.22
      26000        40.5       -21.3               0.86     -35.11         7.02        3.69         2.28
      26500        40.5       -21.1               0.90     -35.20         7.15        3.91         2.36

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  Linear interpolation will be used for frequencies in between the values in the table.
  Table shows an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                                                Page 24 of 28


6.6    ANTENNA EMCO 3160-10 (26.5 GHZ – 40 GHZ)
                                               cable        cable       cable       cable    distance      dLimit       dused
                  AF                          loss 1       loss 2      loss 3      loss 4      corr.      (meas.       (meas.
                EMCO                         (inside      (outside    (switch        (to     (-20 dB/    distance     distance
  Frequency    3160-10       Corr.          chamber)     chamber)       unit)    receiver)   decade)      (limit)      (used)
     GHz       dB (1/m)       dB                dB           dB          dB          dB         dB           m           m
       26.5        43.4       -11.2                4.4                                          -15.6             3         0.5
       27.0        43.4       -11.2                4.4                                          -15.6             3         0.5
       28.0        43.4       -11.1                4.5                                          -15.6             3         0.5
       29.0        43.5       -11.0                4.6                                          -15.6             3         0.5
       30.0        43.5       -10.9                4.7                                          -15.6             3         0.5
       31.0        43.5       -10.8                4.7                                          -15.6             3         0.5
       32.0        43.5       -10.7                4.8                                          -15.6             3         0.5
       33.0        43.6       -10.7                4.9                                          -15.6             3         0.5
       34.0        43.6       -10.6                5.0                                          -15.6             3         0.5
       35.0        43.6       -10.5                5.1                                          -15.6             3         0.5
       36.0        43.6       -10.4                5.1                                          -15.6             3         0.5
       37.0        43.7       -10.3                5.2                                          -15.6             3         0.5
       38.0        43.7       -10.2                5.3                                          -15.6             3         0.5
       39.0        43.7       -10.2                5.4                                          -15.6             3         0.5
       40.0        43.8       -10.1                5.5                                          -15.6             3         0.5

Sample calculation

  E (dB µV/m) = U (dB µV) + AF (dB 1/m) + Corr. (dB)
  U = Receiver reading
  AF = Antenna factor
  Corr. = sum of single correction factors of used cables, switch unit, distance correction, amplifier (if applicable)
  Linear interpolation will be used for frequencies in between the values in the table.
  distance correction = -20 * LOG (dLimit/ dused)
  Linear interpolation will be used for frequencies in between the values in the table.
  Table shows an extract of values.




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                                                Page 25 of 28


7   SETUP DRAWINGS


_____________

Setup Drawings
_____________




Setup in the Anechoic chamber. For measurements below 1 GHz the ground was replaced by a
conducting ground plane.




                LISN                          Analyzer




                                              Signaling
                 EUT
                                                UNIT
 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                                  Page 26 of 28


Setup in the shielded room for conducted measurements at AC mains port




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                              Page 27 of 28


8   MEASUREMENT UNCERTAINTIES


    Test Case                                 Parameter        Uncertainty
    Conducted Emissions at AC mains           Voltage          ± 3.4 dB

    Radiated Emissions                        Field Strength   ± 5.5 dB




9   PHOTO REPORT

Please see separate photo report.




 TEST REPORT REFERENCE: MDE_UBLOX_1712_FCCc                               Page 28 of 28