                                                TEST REPORT
                                               No.: 16-1-0088301T01a



                                                               According to:
                                                             FCC Regulations
                                                        Part 15B: §15.107, §15.109
                                                             Part 15C: §15.207

                                                               IC-Regulations
                                                              ICES-003, Issue 6
                                                               RSS-Gen Issue 4


                                                                 for

                                                          u-Blox AG

                                  GSM/W-CDMA Module SARA-U201
                                                     FCC-ID: XPY1CGM5NNN
                                                      IC: 8595A-1CGM5NNN
                                                        PMN: SARA-U201
                                                        HVIN: SARA-U201


                                             Laboratory Accreditation and Listings




                                                                                                       Voluntary Controls for
                                                                               Industry Canada      Electromagnetic Emissions
                                                                              Reg. No.: 3462D-1             Reg. No.:
                                                       MRA US-EU 0003         Reg. No.: 3462D-2          R-2666 C-2914,
                                                                              Reg. No.: 3462D-3          T-1967, G-301




                                       accredited according to DIN EN ISO/IEC 17025
                                                     CETECOM GmbH
                               Laboratory Radio Communications & Electromagnetic Compatibility
                                           Im Teelbruch 116 • 45219 Essen • Germany
                                  Registered in Essen, Germany, Reg. No.: HRB Essen 8984
                                Tel.: + 49 (0) 20 54 / 95 19-954 • Fax: + 49 (0) 20 54 / 95 19-964
                                    E-mail: info@cetecom.com • Internet: www.cetecom.com




                                                                                                                              Page 1 of 19
The test results relate only to the individual items which have been tested. This report shall not be reproduced in parts without the written
approval of the testing laboratory                                                  © Copyright: All rights reserved by CETECOM


Test Report 16-1-0088301T01a, Page 2 of 19


Table of contents
1. SUMMARY OF TEST RESULTS...................................................................................................................... 3
  1.1. TEST OVERVIEW ACCORDING FCC PART 15B AND CANADIAN RSS- OR ICES STANDARDS .... 3
  1.2. Attestation:....................................................................................................................................................... 3
2. ADMINISTRATIVE DATA ............................................................................................................................... 4
  2.1. Identification of the testing laboratory ............................................................................................................. 4
  2.2. Test location .................................................................................................................................................... 4
  2.3. Organizational items ........................................................................................................................................ 4
  2.4. Applicant’s details ........................................................................................................................................... 4
  2.5. Manufacturer’s details ..................................................................................................................................... 4
3. EQUIPMENT UNDER TEST (EUT) ................................................................................................................. 5
  3.1. EUT: Type, S/N etc. and short descriptions used in this test report ................................................................ 5
  3.2. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions .................................................................. 5
  3.3. EUT set-ups ..................................................................................................................................................... 5
  3.4. EUT operating modes ...................................................................................................................................... 6
  3.5. Configuration of cables used for testing .......................................................................................................... 6
4. DESCRIPTION OF TEST SYSTEM SET-UP’S .............................................................................................. 7
  4.1. Test system set-up for AC power-line conducted emission measurements ..................................................... 7
  4.2. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz ............................................... 8
  4.3. Test system set-up for radiated electric field measurement above 1 GHz ....................................................... 9
5. MEASUREMENTS ............................................................................................................................................. 10
  5.1. General Limit - Conducted emissions on AC-Power lines .............................................................................. 10
  5.2. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz .............................................................. 12
  5.3. General Limit - Radiated emissions, above 1 GHz .......................................................................................... 13
  5.4. Measurement uncertainties .............................................................................................................................. 14
6. ABBREVIATIONS USED IN THIS REPORT ................................................................................................. 15
7. ACCREDITATION DETAILS OF CETECOM’S LABORATORIES AND TEST SITES ......................... 15
8. INSTRUMENTS AND ANCILLARY ................................................................................................................ 16
  8.1. Used equiment “CTC” ..................................................................................................................................... 16
9. VERSIONS OF TEST REPORTS (CHANGE HISTORY) ............................................................................. 19



Table of annex                                                                                                                                         Total pages
Annex 1: Measurement diagrams                                                                                                                                           9
Annex 2: External photographs of EUT                                                                                                                                    8
Annex 3: Internal photographs of EUT                                                                           TO BE PROVIDED BY APPLICANT
Annex 4: Test set-up photographs                                                                                                                                        9

The listed attachments are an integral part of this report.




CETECOM_TR_16_1_0088301T01a


                                                                                                                             CETECOM*
Test Report 16—1—0088301T01a, Page 3 of 19



1. Summary of test results

The test results apply exclusively to the test samples as presented in this Report. The CETECOM GmbH
does not assume responsibility for any conclusions and generalizations taken in conjunction with other
specimens or samples of the type of the item presented to tests. Also we refer on special conditions which
the applicant should fulfill according §2.927 to §2.948, special focus regarding modification of the
equipment and availability of sample equipment for market surveilance tests.

The Equipment Under Test (in this report, hereinafter referred as EUT) supports radiofrequency technologies.

Following tests have been performed to show compliance with applicable Part 15 Subpart B of the FCC CFR Title
47 Rules, Edition 4* November 2014 and Canada ICES—003, Issue RSS—Gen Issue 4 standards.

1.1. TEST OVERVIEW ACCORDING FCC PART 15B AND CANADIAN RSS— OR
ICES STANDARDS
    No. of              T                                       References, Standards & Limits                                EUT
  Diagram                   est            Port                                                                     EUE        op—    Result
                        Cases                             FCC                 IC                  Limits            set—up
    group                                                                                                                     mode
               AC                                       §15.107                .               C Class A
               Power Lines                              §15.207      ,                         & Class B
                                      AC                                                       Chapter 8.8                   1+2+3
       1       Conducted              Power lines          _         Brp—0es.lised              Table 3               2       +4+6   passed
               emissions                                             1CES—003, Issue 5         C Class A
               0,15 — 30 MHz                                           (ANSI C63.4)            B Class B
                    .                 Cabinet +                                               2400/F(kHz)                             See
               Batinted               Inter—                         RSS—Gen., Issue 4            wV/m                               other
       2       emissions              sonfestin         §15.109           Tabi; 5             24000/F(kHz)            ——       —     test
               9 kHz — 30 MHz)        CRRE         €                                              pV/m                                : s
                                                                                                30 uV/m                              Yepo
                                                        §15.109      ICES—003, Issue 6         O Class A
                    .                 Cabinet +             '            (ANSI €63.4)          ® Class B
       3
               Radisted
               emissions
                                      Inter—   g                     RSS—Gen., Issue 4
                                                                                               Chapter    8.9
                                                                                                 ’lfipb]er4.          1       5+6    passed
               30 MHz—1 GHz           connecting           _                                      able
                                      cables                         1CES—003, Issue 6         D Class A
                                                                       (ANSI €63.4)            E® Class B
                                                                                                C Class A
                   ;                  Cabinet +         $15.109                ~                C Class B
               Radicted               Inter—                                                   Chapter 8.9
      4        emissions              gounssting                     RSS—Gen., Issue 4           Table 4              1       4+6    passed
               above 1 GHz                                 xs
                                      cables                         ICES—003, Issue 6         C Class A
                                                                       (ANSI €63.4)            E® Class B
Remark:


1.2. Attestation:
1 declare that all measurements were performed by me or under my supervision and that all measurements have been performed and are correct
to my best knowledge and belief to Industry Canada standards. All requirements as shown in above table are met in accordance with enumerated
standards.




Dipl.—Ing. Rachid Acharkaoui                                                                                         DipL.—Ing. C. Lorenz
Responsible for test section                                                                                    Responsible for test report

                                                       Fax: + 49 (0) 20 &          19 — 897




CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 4 of 19


2. Administrative Data
2.1. Identification of the testing laboratory
Company name:                                                         CETECOM GmbH
Address:                                                              Im Teelbruch 116
                                                                      45219 Essen - Kettwig
                                                                      Germany
Responsible for testing laboratory:                                   Dipl.-Ing. Rachid Acharkaoui
Deputy:                                                               Dipl.-Ing. Niels Jeß

2.2. Test location
2.2.1. Test laboratory “CTC”
Company name:                                                         see chapter 2.1. Identification of the testing laboratory


2.3. Organizational items

Responsible for test report and
project leader:                                                       Dipl.-Ing. C. Lorenz
Receipt of EUT:                                                       2016-05-01
Date(s) of test:                                                      2016-06-13 to 2016-06-17
Date of report:                                                       2016-06-21
       -----------------------------------------------------------------------------------------------------------------------------------------------------

Version of template:             13.02
2.4. Applicant’s details

Applicant’s name:                                                     u-Blox AG
Address:                                                              Zürcherstrasse 68
                                                                      8800 Thalwil

                                                                      Schwitzerland
Contact person:                                                       Mr. Marco Barchitta

2.5. Manufacturer’s details

Manufacturer’s name:                                                  please see Applicant's details

Address:                                                              please see Applicant's details




CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 5 of 19


3. Equipment under test (EUT)

3.1. EUT: Type, S/N etc. and short descriptions used in this test report
Short
                                                                      S/N               HW                SW
descrip-             EUT                       Type
                                                                 serial number     hardware status   software status
tion*)
                                                                    IMEI:
               GSM/W-CDMA
 EUT A                                     SARA-U201            357520070032           261A01             23.56
                  Module
                                                                     566

                                                                    IMEI:
 EUT B         GSM/W-CDMA                  SARA-U201            357520070032           261A01             23.56
                                                                     293
*) EUT short description is used to simplify the identification of the EUT in this test report.



3.2. Auxiliary Equipment (AE): Type, S/N etc. and short descriptions
    AE
                                                                      S/N               HW                SW
   short     Auxiliary Equipment               Type
                                                                 serial number     hardware status   software status
 descrip-
  tion *)
  AE 1       AC/DC power adapter         UUX-324-1215            F04-0026561              -                  -

  AE 2       Evaluation Test Board          EVB-WL3               BS090514                -                  -

  AE 3             Headset                    HDC-5                    -                  -                  -

                                            Taoglas
                                                                GSATT150500
  AE 4         Cellular antenna        GSA.8827.A.101111                                  -                  -
                                                                   1611
                                            phoenix

  AE 5            USB cable            Mini-USB to USB A               --               1.5m                 --

                 Dell Latitude                                                                        Win 7 + Putty
  AE 6                                         2120              “ctc062011”              --
                  notebook                                                                              program
*) AE short description is used to simplify the identification of the auxiliary equipment in this test report.



3.3. EUT set-ups

 EUT set-up
                       Combination of EUT and AE                                      Remarks
   no.*)

                EUT A + AE 1 + AE 2+ AE 3+ AE 4 + AE
    set. 1                                                                  Used for radiated measurements
                              5 + AE 6

                EUT B + AE 1 + AE 2+ AE 3+ AE 4 + AE
    set. 2                                                         Used for conducted AC-mains measurements
                              5 + AE 6
*) EUT set-up no. is used to simplify the identification of the EUT set-up in this test report.



CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 6 of 19

3.4. EUT operating modes
EUT          Description of      Additional information
operating    operating modes
mode
no.*)
                GPRS 850       A communication link is established between the mobile station and the test
              Traffic channel  simulator. The transmitter is operated at its maximum rated output
                   =192        power: 33 dBm (power class 4; power control level 5). USF_Duty CYCLE set to
                               100%, coding scheme CS-1 for GMSK modulation, slot 3 active, uplink gamma: 3
    op. 1
                               (33 dBm).
                               The input signal to the receiver is modulated with normal test modulation. The
                               wanted RF input signal level to the receiver of the mobile station is set to a level to
                               provide a stable communication link.
                GSM 850        The mobile station is synchronized to the Broadcast Control Channel (BCCH) and
             Registered/RX- listening to the Common Control Channel (CCCH). Periodic location update is
            Mode/Idle mode disabled.
    op. 2
                   on
                 Ch 192
               BCCH 50
                               A communication link is established between the mobile station (UE) and the test
                               simulator. The transmitter is operated on its maximum rated output
              FDD-Band 5       power class: 24dBm nominal.
    op. 3     Channel 4185     The input signal to the receiver is modulated with normal test modulation.
            12.2 kbps RMC The wanted RF input signal level to the receiver of the mobile station is set to a
                               level to provide a stable communication link according Table E5.1/Table E5.1A as
                               described in 3GPP TS34.121, Annex E.
              Synchronized
              FDD Band 5
                               The mobile station is synchronized to the Node B station. The Node B downlink
    op. 4
                               physical channels settings according Table E.5.1/E.5.1A in 3GPP TS34.121.
             Registered/RX-
            Mode on Ch4185
               GSM 1900        The mobile station is synchronized to the Broadcast Control Channel (BCCH) and
             Registered/RX- listening to the Common Control Channel (CCCH). Periodic location update is
            Mode/Idle mode disabled.
    op. 5
                   on
                 Ch 661
              BCCH 651
                               A PC is connected over an USB cable to the board (EUT). Continuous data transfer
    op. 6     Data transfer
                               is initiated from PC over the USB Port to the EUT.
*) EUT operating mode no. is used to simplify the test report.



3.5. Configuration of cables used for testing
  Cable
                                                                    S/N              HW            Cable length
 number              Item                    Type
                                                               serial number    hardware status
Cable 1           USB cable           Mini-USB to USB A              --                --              1.5m




CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 7 of 19


4. Description of test system set-up’s
4.1. Test system set-up for AC power-line conducted emission measurements


 Specification:               ANSI C63.4-2014 chapter 7, ANSI C63.10-2013 chapter 6.2

 General Description:         The radio frequency voltage conducted back into the AC power line in the frequency
                              range 150 kHz to 30 MHz has to be investigated. Compliance should be tested by
                              measuring the radio frequency voltage between each power line and ground at the
                              power terminals in the stated frequency range.
                              A 50 Ohm / 50 µH line impedance stabilization network (LISN) is used coupling the
                              interface to the measurement equipment. The EUT power input leads are connected
                              through the LISN to the AC-power source. The LISN enclosure is electrically
                              connected to the ground plane. The measuring instrument is connected to the coaxial
                              output of the LISN.
                              Tabletop devices were set-up on a 80 cm height above reference ground plane, floor
                              standing equipment 10 cm raised above ground plane. Measurements have been
                              performed on each phase line and neutral line of the devices AC-power lines. The
                              EUT was power supplied with 110 V/60 Hz. The EUT was tested in the defined
                              operating mode and installed (connected) to accessory equipment according the
                              general description of use given by the applicant.

 Schematic:




                              Only schematic view, we refer to figure 6, 7 and 8 of ANSI C63.4-2009 for more details.



 Testing method:              Exploratory, preliminary measure-                  Final testing for power phases and
                              ments as a first step, determines the              critical frequencies (Margin to AV- or QP
                              worst-case phase line (neutral or phase)           limit lower than 3 dB) as a second step
                              as well as the most critical operating             includes measurements with receivers
                              mode of the equipment. A complete                  detector set to Quasi-Peak and Average.
                              frequency-sweep with PK-Detector is
                              performed on each current-carrying
                              conductor.
 Formula:                     VC= VR + CL (1)                          VC = measured Voltage –corrected value
                              M= LT-VC (2)                             VR = Receiver reading
                                                                       CL = Cable loss
                                                                       M = Margin
                                                                       LT = Limit
                              Values are in dB, positive margin means value is below limit.




CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 8 of 19

4.2. Test system set-up for radiated electric field measurement 30 MHz to 1 GHz
 Specification:               ANSI C63.4-2014 chapter 8.2.3, ANSI C63.10-2013 chapter 6.5

 General Description:         Evaluating the field emissions have to be done first by an exploratory emissions
                              measurement and a final measurement for most critical frequencies. The tests are
                              performed in a NSA-compliant semi anechoic room (SAR) recognized by the
                              regulatory commissions.

 Schematic:




 Testing method:              Exploratory, preliminary measurements                Final measurement on critical frequencies
                              The EUT and its associated accessories are placed    Based on the exploratory measurements, the most
                              on a non-conductive position manipulator (tipping    critical frequencies are re-measured by main-
                              device) of 0.8 m height which is placed on the       taining the EUT’s worst-case operation mode, cable
                              turntable. By rotating the turntable (range 0° to    position, etc. either on 10m OATS or 3m semi-
                              360°, step 90°) and the EUT itself either on 3-      anechoic room.
                              orthogonal axis (portable equipment) or 2-
                              orthogonal axis (defined operational position of     First a frequency zoom around the critical frequency
                              EUT) the emission spectrum and it’s                  is done to locate the frequency more precisely. After
                              characteristics was recorded with an EMI-            this step, for all identified critical frequencies, the
                              receiver, broadband antenna and software.            maximum peak was determined.

                              Measurement antenna: horizontal and vertical,        Following parameters were varied: the turntable
                              heights: 1,0 m and 1,82 m as worst-case              angle continuously in the range 0 to 360 degree, the
                              determined by an exploratory emission                EUT itself either over 3-orthogonal axis (not
                              measurements. The results are documented in a        defined usage position) or 2-orthogonal axis
                              diagram. Critical frequencies (low margin to         (defined usage position). The measurement antenna
                              limit) are saved within a table for further          height between 1 m and 4 m.
                              investigations. If various operating modes are
                              supported, further investigations are made to find   On the determined worst-case position, a final
                              the worst-case of them. Also the interconnection     measurement with necessary bandwidth and
                              cables and equipment position were varied in         detector according standard has been carried out.
                              order to maximize the emissions.

 Formula:                     EC = ER + AF + CL + DF - GA (1)           AF = Antenna factor
                                                                        CL = Cable loss
                              M = LT - EC         (2)                   DF = Distance correction factor (if used)
                                                                        EC = Electrical field – corrected value
                                                                        ER = Receiver reading
                                                                        GA = Gain of pre-amplifier (if used)
                                                                        LT = Limit
                                                                        M = Margin
                              All units are dB-units, positive margin means value is below limit.




CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 9 of 19

4.3. Test system set-up for radiated electric field measurement above 1 GHz
 Specification:               ANSI C63.4-2014 chapter 8.3, ANSI C63.10-2013 chapter 6.6.3.3 & 6.6.4

 General Description:         Evaluating the emissions have to be done first by an exploratory emissions
                              measurement and a final measurement for most critical frequencies. The tests are
                              performed in a CISPR 16-1-4:2010 compliant fully anechoic room (FAR)
                              recognized by the regulatory commission. The measurement distance was set to 3
                              meter for frequencies up to 18 GHz and 2 meter above 18 GHz. A logarithmic
                              periodic antenna is used for the frequency range 30 MHz to 1 GHz. Horn antennas
                              are used for frequency range 1 GHz to 40 GHz. The EUT is aligned within 3 dB
                              beam width of the measurement antenna with three orthogonal axis measurements
                              on the EUT.

 Schematic:




 Testing method:              Exploratory, preliminary measurements                Final measurement on critical frequencies
                              The EUT and its associated accessories are placed    Based on the exploratory measurements, the most
                              on a non-conductive position manipulator (tipping    critical frequencies are re-measured by main-
                              device) of 1.55 m height which is placed on the      taining the EUT’s worst-case operation mode,
                              turntable. By rotating the turntable (range 0° to    cable position, etc.
                              360°, step 15°) and the EUT itself either on 3-
                              orthogonal axis (portable equipment) or 2-           First a frequency zoom around the critical
                              orthogonal axis (defined operational position of     frequency is done to locate the frequency more
                              EUT) the emission spectrum and it’s                  precisely. After this step, for all identified critical
                              characteristics was recorded with an EMI-            frequencies, the maximum peak was determined.
                              receiver, broadband antenna and software.            Following parameters were varied: the turntable
                              The measurements are performed in horizontal         angle continuously in the range 0 to 360 degree,
                              and vertical polarization of the measurement         the EUT itself over 3-orthogonal axis and the
                              antennas. The results are documented in a            height for EUT with large dimensions.
                              diagram. Critical frequencies (low margin to
                              limit) are saved within a table for further          On the determined worst-case position, a final
                              investigations. If various operating modes are       measurement with necessary bandwidth and
                              supported, further investigations are made to find   detector according standard has been carried out.
                              the worst-case of them. Also the interconnection     On the determined worst-case position, a final
                              cables and equipment position were varied in         measurement with necessary bandwidth and
                              order to maximize the emissions.                     detector according standard has been carried out.

 Formula:                     EC = ER + AF + CL + DF - GA (1)           EC = Electrical field – corrected value
                                                                        ER = Receiver reading
                              M = LT - EC         (2)                   M = Margin
                                                                        LT = Limit
                                                                        AF = Antenna factor
                                                                        CL = Cable loss
                                                                        DF = Distance correction factor (if used)
                                                                        GA = Gain of pre-amplifier (if used)
                              All units are dB-units, positive margin means value is below limit.




CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 10 of 19


5. Measurements
5.1. General Limit - Conducted emissions on AC-Power lines
5.1.1. Test location and equipment
test location    CETECOM Essen (Chapter 2.2.1)          Please see Chapter 2.2.2                Please see Chapter 2.2.3
 test site       333 EMI field  348 EMI cond.
 receiver        001 ESS           377 ESCS 30         489   ESU 40      620 ESU 26
 LISN            005 ESH2-Z5  007 ESH3-Z6              300   ESH3-Z5 & 50 used for AE         no LISN for AE
 signaling       392 MT8820A  436 CMU                  547   CMU         594 CMW
 line voltage    230 V 50 Hz via public mains           060    120 V 60 Hz via PAS 5000



5.1.2. Requirements
           FCC                 Part 15, Subpart B, §15.107
            IC                 RSS-Gen Issue 4, Chapter 8.8, Table 3
          ANSI                 C63.4-2014, § 5.2, 6, 7 for un-intentional transmitter mode / C63.10-2013 for Intentional Transmitter mode
                Frequency                   Conducted limit Class B                                Conducted limit Class A
                  [MHz]         QUASI-Peak [dBµV]            AVERAGE [dBµV]             QUASI-Peak [dBµV]            AVERAGE [dBµV]
   Limit        0.15 – 0.5            66 to 56*                    56 to 46*                      79                         66
                  0.5 – 5                 56                          46                          73                         60
                  5 – 30                  60                          50                          73                         60
 Remark: * decreases with the logarithm of the frequency



5.1.3. Test condition and test set-up
Signal link to test system (if used):        air link  cable connection  none
EUT-grounding                                none  with power supply  additional connection
Equipment set up                             table top                        floor standing
                                            (40 cm distance to reference       EUT stands isolated on reference ground plane (floor)
                                            ground plane (wall)
Climatic conditions                         Temperature: (22±3°C)             Rel. humidity: (40±20)%
                                             9 – 150 kHz,            RBW = 200 Hz, Step = 61 Hz
                   Scan data                 150 kHz – 30 MHz        RBW = 9 kHz,       Step = 4 kHz
 EMI-Receiver or                             other:
 Analyzer settings Scan-Mode                6 dB EMI-Receiver Mode
                   Pre-measurement          Peak detector, Repetitive-Scan, max-hold, sweep-time 50 µs per frequency point
                   Final measurement        Average & Quasi-peak detector at critical frequencies
General measurement procedures              Please see chapter “Test system set-up for AC power line conducted emissions measurements”




CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 11 of 19

5.1.4. Measurement results accord. §15.107
The results are presented below in summary form only. For more information please see the diagrams
 EUT                set-up no.:                   set-up 2
                   EUT
 Diagram-                                          Power Additional (scan-) information or         Result
              operating mode     Used Detector
    No.                                              line                  remarks
             no. or commend
                   EUT           Peak (pre-scan)            Tests on AC-port of AC/DC Adapter.
    1.02      operating mode  CAV (final)         L1/ N     Idle on channel 192 (GSM850) Data     passed
                    2+6          QP   (final)                      transfer over USB to PC
                   EUT           Peak (pre-scan)            Tests on AC-port of AC/DC Adapter.
    1.04      operating mode  CAV (final)         L1/ N Idle on channel 4185 (FDD Band 5) Data    passed
                    4+6          QP   (final)                      transfer over USB to PC



5.1.5. Measurement results accord. §15.207
 EUT              set-up no.:                   set-up 2
                  EUT
 Diagram-                                        Power      Additional (scan-) information or       Result
            operating mode     Used Detector
    No.                                            line                  remarks
            no. or commend
                  EUT          Peak (pre-scan)             Tests on AC-port of AC/DC Adapter.
    1.01    operating mode  CAV (final)         L1/ N      GSM850 TCH on channel 4185 + Data       passed
                   1+6         QP   (final)                       transfer over USB to PC
                  EUT          Peak (pre-scan)              - Tests on AC-port of AC/DC Adapter.
    1.03    operating mode  CAV (final)         L1/ N        FDD Band 5 TCH on channel 4185 +      passed
                   3+6         QP   (final)                      Data transfer over USB to PC




CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 12 of 19

5.2. General Limit - Radiated field strength emissions, 30 MHz - 1 GHz
5.2.1. Test location and equipment
 test location      CETECOM Essen (Chapter. 2.2.1)            Please see Chapter. 2.2.2               Please see Chapter. 2.2.3
 test site          441 EMI SAR  487 SAR NSA
 receiver           377 ESCS30        001 ESS                489 ESU 40       620 ESU 26
 spectr. analys.    584 FSU           120 FSEM               264 FSEK
 antenna            574 BTA-L         133 EMCO3115           302 BBHA9170  289 CBL 6141      030 HFH-Z2  477 GPS
 signaling          392 MT8820A  371 CBT32                   547 CMU          594 CMW
 otherwise          400 FTC40x15E  401 FTC40x15E             110 USB LWL  482 Filter Matrix
 DC power           456 EA 3013A  457 EA 3013A               459 EA 2032-50  268 EA- 3050    494 AG6632A  498 NGPE
 line voltage       230 V 50 Hz via public mains              060 120 V 60 Hz via PAS 5000



5.2.2. Requirements/Limits
                    FCC                        Part 15 Subpart B, §15.109, class B
                                               Part 15 Subpart C, §15.209 @ frequencies defined in §15.205
                                               RSS-Gen., Issue 4, Chapter 8.9, Table 4+6 (licence-exempt radio apparatus)
                                               RSS-Gen., Issue 4, Chapter 7.1.2, Table 2 (receiver)
                      IC
                                               ICES-003, Issue 6, Table 5 (Class B)
                                               RSS-247, Issue 1, Chapter 5
                                               C63.4-2014
                   ANSI
                                               C63.10-2013
                                                                         Radiated emissions limits, 3 meters
                      Frequency [MHz]
                                                            QUASI Peak [µV/m]                          QUASI-Peak [dBµV/m]
                             30 - 88                              100                                         40.0
    Limit
                            88 - 216                              150                                         43.5
                           216 - 960                              200                                         46.0
                           above 960                              500                                         54.0



5.2.3. Test condition and measurement test set-up
Signal link to test system (if used):         air link       cable connection        none
 EUT-grounding                                none           with power supply  additional connection
 Equipment set up                             table top 0.8m height                  floor standing
 Climatic conditions                         Temperature: (22±3°C)                   Rel. humidity: (40±20)%
 EMI-Receiver          Scan frequency         30 – 1000 MHz  other:
(Analyzer) Settings range:                    6 dB EMI-Receiver Mode  3 dB spectrum analyser mode
                       Scan-Mode             Peak / Quasi-peak
                       Detector              100 kHz/300 kHz
                       RBW/VBW               Repetitive-Scan, max-hold
                       Mode:                 80 kHz
                       Scan step             Coupled – calibrated display if continuous tx-signal otherwise adapted to EUT’s individual duty-
                       Sweep-Time            cycle

General measurement procedures               Please see chapter “Test system set-up for electric field measurement in the range 30 MHz
                                              to 1 GHz”



5.2.4. MEASUREMENT RESULTS

The results are presented below in summary form only. For more information please consult the diagrams
included in annex 1.

Table of measurement results:
                                                                                                                                     Result
   Dia-       Carrier Channel                        Set-       OP-                                           Used detector
                                       Frequency
   gram                                               up        mode                  Remark
                                         range
    no.                                              no.         no.
              Range         No.                                                                              PK     AV     QP
                                       30 MHz –
   3.02      Middle         661                        1         5+6          IDLE on Chanel 661                                  passed
                                        1 GHz
 Remark:




CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 13 of 19

5.3. General Limit - Radiated emissions, above 1 GHz
5.3.1. Test location and equipment FAR
 test site          441 EMI SAR  348 EMI cond.              443   EMI FAR     347 Radio.lab. 337 OATS               
 spectr. analys.    584 FSU          120 FSEM               264   FSEK        489 ESU 40                            
 antenna meas       574 BTA-L        289 CBL 6141           608   HL 562      549 HL025      302 BBHA9170            477 GPS
 antenna meas       123 HUF-Z2       132 HUF-Z3             030   HFH-Z2      376 BBHA9120E                          
 antenna subst      071 HUF-Z2       020 EMCO3115           063   LP 3146     303 BBHA9170                          
 multimeter         341 Fluke 112                                                                                   
 signaling          392 MT8820A  371 CBT32                  547   CMU         594 CMW
 DCpower            086 LNG50-10  087 EA3013                354   NGPE 40  349 car battery 350 Car battery          
 line voltage       230 V 50 Hz via public mains             060   120 V 60 Hz via PAS 5000

5.3.2. Requirements/Limits
                           Part 15 Subpart B, §15.109 class B
          FCC              Part 15 Subpart C, §15.209 for frequencies defined in §15.205
                           Part 15 Subpart C, §15.407(b)(1)(2)(3) 9

                           RSS-Gen., Issue 4, Chapter 8.9, Table 4+6 (transmitter licence excempt)
                           RSS-Gen., Issue 4, Chapter 8.9, Table 2 (receiver)
          IC
                           ICES-003, Issue 6, Chapter 6.2.2, Table 7 (class B)
                           RSS-247, Issue 1, Chapter 6

                           C63.4-2014
        ANSI
                           C63.10-2013
                                                                                   Limits
      Frequency                       AV                                AV                           Peak                   Peak
        [MHz]                       [µV/m]                           [dBµV/m]                       [µV/m]               [dBµV/m] or
                                                                                                                         [dBm/MHz]
    above 1 GHz
 for frequencies as
 defined in §15.205
                                         500                           54.0                          5000                74.0 dBµV/m
         or
 RSS-Gen., Issue 4,
  §8.10 - Table 6

5.3.3. Test condition and measurement test set-up
 Signal link to test system (if used):          air link      cable connection       none
 EUT-grounding                                  none          with power supply  additional connection
 Equipment set up                               table top 1.5m height                 floor standing
 Climatic conditions                           Temperature: (22±3°C)                  Rel. humidity: (40±20)%
Spectrum- Scan frequency range:                 1 – 18 GHz  18 – 25 GHz  18 – 40 GHz  other:
Analyzer      Scan-Mode                         6 dB EMI-Receiver Mode  3 dB Spectrum analyser Mode
settings      Detector                         Peak and Average
              RBW/VBW                          1 MHz / 3 MHz
              Mode:                            Repetitive-Scan, max-hold
              Scan step                        400 kHz
              Sweep-Time                       Coupled – calibrated display if CW signal otherwise adapted to EUT’s individual duty-cycle
General measurement procedures                 Please see chapter “Test system set-up for radiated electric field measurements above 1 GHz”

5.3.4. Measurement Results

The results are presented below in summary form only. For more information please consult the diagrams
included in annex 1.


   Dia-        Carrier Channel                        Set-       OP-                                          Used detector        Result
                                     Frequency
   gram                                                up        mode                   Remark
                                       range
    no.                                               no.         no.
                Range       No.                                                                              PK     AV       QP
 4.01          Middle    192        1-18GHz            1         4+6          Idle on channel 192                               passed
Remark: see diagrams in annex 1 for more details




CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 14 of 19

5.4. Measurement uncertainties

The reported uncertainties are calculated based on the standard uncertainty multiplied with the appropriate
coverage factor k, such that a confidence level of approximately 95% is achieved.
For uncertainty determination, each component used in the concrete measurement set-up was taken in account and
it’s contribution to the overall uncertainty according it’s statistical distribution calculated.

Following table shows expectable uncertainties for each measurement type performed.

                                                                       Calculated uncertainty based on a
     RF-Measurement            Reference        Frequency range                                                  Remarks
                                                                           confidence level of 95%
 Conducted emissions                       9 kHz - 150 kHz         4.0 dB
                              CISPR 16-2-1                                                                           -
 (U CISPR)                                 150 kHz - 30 MHz        3.6 dB
 Radiated emissions                        30 MHz - 1 GHz          4.2 dB
                              CISPR 16-2-3                                                                        E-Field
 Enclosure                                 1 GHz - 18 GHz          5.1 dB
 Disturbance power            CISPR 16-2-2 30 MHz - 300 MHz        -                                                 -
                                                                                                                Substitution
 Power Output radiated             -          30 MHz - 4 GHz       3.17 dB
                                                                                                                method
                                                                   Cel- Cel-
                                              Set-up No.                        BT1 W1          W2         --
                                                                    C1     C2
 Power Output conducted            -          9 kHz - 12.75 GHz    N/A 0.60 0.7 0.25           N/A         --        -
                                              12.75 - 26.5GHz      N/A 0.82      --   N/A      N/A         --
 Conducted emissions               -          9 kHz - 2.8 GHz      0.70 N/A 0.70 N/A           0.69        --    N/A - not
 on RF-port                                   2.8 GHz - 12.75GHz   1.48 N/A 1.51 N/A           1.43        --    applicable
                                              12.75 GHz - 18GHz    1.81 N/A 1.83 N/A           1.77        --
                                              18 GHz - 26.5GHz     1.83 N/A 1.85 N/A           1.79        --
                                                                   0.1272 ppm (Delta Marker)                    Frequency
 Occupied bandwidth                -          9 kHz - 4 GHz                                                     error
                                                                   1.0 dB                                       Power
                                   -                               0.1272 ppm (Delta Marker)                    Frequency
 Emission bandwidth                           9 kHz - 4 GHz                                                     error
                                   -                               See above: 0.70 dB                           Power
 Frequency stability               -          9 kHz - 20 GHz       0.0636 ppm                                         -
                                              150 kHz - 30 MHz     5.0 dB                                       Magnetic
 Radiated emissions                           30 MHz - 1 GHz       4.2 dB                                       field
                                   -
 Enclosure                                    1 GHz - 20 GHz       3.17 dB                                      E-field
                                                                                                                Substitution
Table: measurement uncertainties, valid for conducted/radiated measurements




CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 15 of 19


6. Abbreviations used in this report
 The abbreviations
 ANSI                    American National Standards Institute
 AV , AVG, CAV           Average detector
 EIRP                    Equivalent isotropically radiated power, determined within a separate measurement
 EGPRS                   Enhanced General Packet Radio Service
 EUT                     Equipment Under Test
 FCC                     Federal Communications Commission, USA
 IC                      Industry Canada
 n.a.                    not applicable
 Op-Mode                 Operating mode of the equipment
 PK                      Peak
 RBW                     resolution bandwidth
 RF                      Radio frequency
 RSS                     Radio Standards Specification, Dokuments from Industry Canada
 Rx                      Receiver
 TCH                     Traffic channel
 Tx                      Transmitter
 QP                      Quasi peak detector
 VBW                     Video bandwidth
 ERP                     Effective radiated power




7. Accreditation details of CETECOM’s laboratories and test sites

 Ref.-   Accreditation                  Valid for laboratory area or test site
 No.      Certificate                                                                               Accreditation Body
 -          D-PL-                                                                             DAkkS, Deutsche
                         All laboratories and test sites of CETECOM GmbH, Essen
         12047-01-01                                                                          Akkreditierungsstelle GmbH
 337                 Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
                                                                                              FCC, Federal Communications
 487                 Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
      (MRA US-EU                                                                              Commission
 558                 Radiated Measurements above 1 GHz, 3 m (FAR)
          0003)                                                                               Laboratory Division, USA
 348                 Mains Ports Conducted Interference Measurements
 348                 Telecommunication Ports Conducted Interference Measurem.
 337    3462D-1      Radiated Measurements 30 MHz to 1 GHz, 3 m / 10 m (OATS)
 487    3462D-2      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)                         IC, Industry Canada Certification
 550    3462D-2      Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)                          and Engineering Bureau
 558    3462D-3      Radiated Measurements above 1 GHz, 3 m (FAR)
 487     R-2666      Radiated Measurements 30 MHz to 1 GHz, 3 m (SAR)
                                                                                              VCCI, Voluntary Control Council
 550     G-301       Radiated Measurements 1 GHz to 6 GHz, 3 m (SAR)
                                                                                              for Interference by Information
 348     C-2914      Mains Ports Conducted Interference Measurements
                                                                                              Technology Equipment, Japan
 348     T-1967      Telecommunication Ports Conducted Interference Measurem.
 OATS = Open Area Test Site, SAR = Semi Anechoic Room, FAR = Fully Anechoic Room




CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 16 of 19


8. Instruments and Ancillary
8.1. Used equiment “CTC”
The “Ref.-No” in the left column of the following tables allows the clear identification of the laboratory
equipment.


8.1.1. Test software and firmware of equipment
  Ref.-No.




                            Equipment                            Type                  Serial-No.       Version of Firmware or Software during the test


001          EMI Test Receiver                         ESS                      825132/017          Firm.= 1.21 , OTP=2.0, GRA=2.0
012          Signal Generator (EMS-cond.)              SMY 01                   839069/027          Firm.= V 2.02
013          Power Meter (EMS cond.)                   NRVD                     839111/003          Firm.= V 1.51
017          Digital Radiocommunication Tester         CMD 60 M                 844365/014          Firmware = V 3.52 .22.01.99, DECT = D2.87 13.01.99
053          Audio Analyzer                            UPA3                     860612/022          Firm. V 4.3
119          RT Harmonics Analyzer dig. Flickermeter   B10                      G60547              Firm.= V 3.1DHG
140          Signal Generator                          SMHU                     831314/006          Firm.= 3.21
261          Thermal Power Sensor                      NRV-Z55                  825083/0008         EPROM-Datum 02.12.04, SE EE 1 B
262          Power Meter                               NRV-S                    825770/0010         Firm.= 2.6
263          Signal Generator                          SMP 04                   826190/0007         Firm.=3.21
                                                                                                    UNIT Firmware= 4.04, SW-Main=4.04, SW-BBP=1.04,
295          Racal Digital Radio Test Set              6103                     1572
                                                                                                    SW-DSP=1.02, Hardboot=1.02, Softboot=2.02
                                                                                                    R&S Test Firmware =3.53 /3.54 (current Testsoftw. f.
298          Univ. Radio Communication Tester          CMU 200                  832221/091
                                                                                                    all band used
323          Digital Radiocommunication Tester         CMD 55                   825878/0034         Firm.= 3.52 .22.01.99
335          CTC-EMS-Conducted                         System EMS Conducted     -                   EMC 32 V 8.52
340          Digital Radiocommunication Tester         CMD 55                   849709/037          Firm.= 3.52 .22.01.99
355          Power Meter                               URV 5                    891310/027          Firm.= 1.31
365          10V Insertion Unit 50 Ohm                 URV5-Z2                  100880              Eprom Data = 31.03.08
366          Ultra Compact Simulator                   UCS 500 M4               V0531100594         Firm. UCS 500=001925/3.06a02, rc=ISMIEC 4.10
371          Bluetooth Tester                          CBT32                    100153              CBT V5,30+ SW-Option K55, K57
377          EMI Test Receiver                         ESCS 30                  100160              Firm.= 2.30, OTP= 02.01, GRA= 02.36
378          Broadband RF Field Monitor                RadiSense III            03D00013SNO-08      Firm.= V.03D13
389          Digital Multimeter                        Keithley 2000            0583926             Firm. = A13 (Mainboard) A02 (Display)
                                                                                                    Firm.= 4.50 #005, IPL=4.01#001,OS=4.02#001,
392          Radio Communication Tester                MT8820A                  6K00000788          GSM=4.41#013, W-CDMA= 4.54#004, scenario=
                                                                                                    4.52#002
                                                                                                    R&S Test Firmware Base=5.14, Mess-Software=
436          Univ. Radio Communication Tester          CMU 200                  103083
                                                                                                    GSM:5.14 WCDMA:5.14 (current Testsoftw. F. all band
441          CTC-SAR-EMI Cable Loss                    System EMI field (SAR)   -                   EMC 32 Version 8.52
442          CTC-SAR-EMS                               System EMS field (SAR)   -                   EMC 32 Version 8.40
                                                       System CTC-FAR-EMI-
443          CTC-FAR-EMI-RSE                                                    -                   Spuri 7.2.5 or EMC 32 Ver. 9.15.00
                                                       RSE
444          CTC-FAR-EMS field                         System-EMS-Field (FAR)   -                   EMC 32 Version 9.15.00
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
460          Univ. Radio Communication Tester          CMU 200                  108901
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used,
489          EMI Test Receiver                         ESU40                    1000-30             Firmware=4.43 SP3, Bios=V5.1-16-3, Spec. =01.00
491          ESD Simulator dito                        ESD dito                 dito307022          V 2.30
524          Voltage Drop Simulator                    VDS 200                  0196-16             Software Nr: 000037 Version V4.20a01
526          Burst Generator                           EFT 200 A                0496-06             Software Nr. 000034 Version V2.32
527          Micro Pulse Generator                     MPG 200 B                0496-05             Software-Nr. 000030 Version V2.43
528          Load Dump Simulator                       LD 200B                  0496-06             Software-Nr. 000031 Version V2.35a01
                                                                                                    R&S Test Firmware Base=5.14, GSM=5.14
546          Univ. Radio Communication Tester          CMU 200                  106436
                                                                                                    WCDMA=5.14 (current Testsoftw.,f. all band to be used
                                                                                                    R&S Test Firmware Base=V5.1403 (current Testsoftw.,
547          Univ. Radio Communication Tester          CMU 200                  835390/014
                                                                                                    f. all band used, GSM = 5.14 WCDMA: = 5.14
584          Spectrum Analyzer                         FSU 8                    100248              2.82_SP3
                                                                                                    R&S Test Firmware Base=5.01, GSM=5.02 WCDMA=
597          Univ. Radio Communication Tester          CMU 200                  100347
                                                                                                    not installed, Mainboard= µP1=V.850
598          Spectrum Analyzer                         FSEM 30 (Reserve)        831259/013          Firmware Bios 3.40 , Analyzer 3.40 Sp 2
620          EMI Test Receiver                         ESU 26                   100362              4.43_SP3
642          Wideband Radio Communication Tester       CMW 500                  126089              Setup V03.26, Test programm component V03.02.20
670          Univ. Radio Communication Tester          CMU 200                  106833              µP1 =V8.50, Firmware = V.20
689          Vector Signal Generator                   SMU200                   100970              02.20.360.142
                                                                                                    CBT V 5.40, FW: V.2.41 (FPGA Digital, V. 3.09 FPGA
692          Bluetooth Tester                          CBT 32                   100236
                                                                                                    RF)




8.1.2. Single instruments and test systems


CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 17 of 19
 Ref.-No.




                                                                                                                          calibration
                                                                                                                          Interval of



                                                                                                                                            Remark
                           Equipment                           Type                 Serial-No.        Manufacturer                                       Cal
                                                                                                                                                         due

001         EMI Test Receiver                         ESS                      825132/017        Rohde & Schwarz          12 M          -            30.05.2017
005         AC - LISN (50 Ohm/50µH, test site 1)      ESH2-Z5                  861741/005        Rohde & Schwarz          12 M          -            30.05.2017
007         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                  892563/002        Rohde & Schwarz          12 M          -            30.05.2017
009         Power Meter (EMS-radiated)                NRV                      863056/017        Rohde & Schwarz          24 M          -            30.04.2017
016         Line Impedance Simulating Network         Op. 24-D                 B6366             Spitzenberger+Spies      36 M          -            30.05.2019
020         Horn Antenna 18 GHz (Subst 1)             3115                     9107-3699         EMCO                     36/12 M       -            31.03.2017
021         Loop Antenna (H-Field)                    6502                     9206-2770         EMCO                     36 M          -            30.04.2018
030         Loop Antenna (H-field)                    HFH-Z2                   879604/026        Rohde & Schwarz          36 M          -            30.04.2018
033         RF-current probe (100kHz-30MHz)           ESH2-Z1                  879581/18         Rohde & Schwarz          24 M          -            30.04.2017
057         relay-switch-unit (EMS system)            RSU                      494440/002        Rohde & Schwarz          pre-m         1a
060         power amplifier (DC-2kHz)                 PAS 5000                 B6363             Spitzenberger+Spies      -             3
                                                      WRCT 1900/2200-5/40-
066         notch filter (WCDMA; FDD1)                                         5                 Wainwright GmbH          12 M          1g           30.06.2016
                                                      10EEK
086         DC - power supply, 0 -10 A                LNG 50-10                -                 Heinzinger Electronic    pre-m         2
087         DC - power supply, 0 -5 A                 EA-3013 S                -                 Elektro Automatik        pre-m         2
091         USB-LWL-Converter                         OLS-1                    007/2006          Ing. Büro Scheiba        -             4
099         passive voltage probe                     ESH2-Z3                  299.7810.52       Rohde & Schwarz          36 M          -            30.04.2018
100         passive voltage probe                     Probe TK 9416            without           Schwarzbeck              36 M          -            30.04.2018
110         USB-LWL-Converter                         OLS-1                    -                 Ing. Büro Scheiba        -             4
119         RT Harmonics Analyzer dig. Flickermeter   B10                      G60547            BOCONSULT                36 M          -            30.05.2019
136         adjustable dipole antenna (Dipole 1)      3121C-DB4                9105-0697         EMCO                     36 M          -            30.04.2018
140         Signal Generator                          SMHU                     831314/006        Rohde & Schwarz          24 M          -            30.05.2018
248         attenuator                                SMA 6dB 2W               -                 Radiall                  pre-m         2
249         attenuator                                SMA 10dB 10W             -                 Radiall                  pre-m         2
252         attenuator                                N 6dB 12W                -                 Radiall                  pre-m         2
256         attenuator                                SMA 3dB 2W               -                 Radiall                  pre-m         2
257         hybrid                                    4031C                    04491             Narda                    pre-m         2
260         hybrid coupler                            4032C                    11342             Narda                    pre-m         2
261         Thermal Power Sensor                      NRV-Z55                  825083/0008       Rohde & Schwarz          24 M          -            30.05.2018
262         Power Meter                               NRV-S                    825770/0010       Rohde & Schwarz          24 M          -            30.05.2018
263         Signal Generator                          SMP 04                   826190/0007       Rohde & Schwarz          36 M          -            30.05.2019
265         peak power sensor                         NRV-Z33, Model 04        840414/009        Rohde & Schwarz          24 M          -            30.05.2018
266         Peak Power Sensor                         NRV-Z31, Model 04        843383/016        Rohde & Schwarz          24 M          -            30.05.2018
267         notch filter GSM 850                      WRCA 800/960-6EEK        9                 Wainwright GmbH          pre-m         2
270         termination                               1418 N                   BB6935            Weinschel                pre-m         2
271         termination                               1418 N                   BE6384            Weinschel                pre-m         2
272         attenuator (20 dB) 50 W                   Model 47                 BF6239            Weinschel                pre-m         2
273         attenuator (10 dB) 100 W                  Model 48                 BF9229            Weinschel                pre-m         2
274         attenuator (10 dB) 50 W                   Model 47 (10 dB) 50 W    BG0321            Weinschel                pre-m         2
275         DC-Block                                  Model 7003 (N)           C5129             Weinschel                pre-m         2
276         DC-Block                                  Model 7006 (SMA)         C7061             Weinschel                pre-m         2
279         power divider                             1515 (SMA)               LH855             Weinschel                pre-m         2
287         pre-amplifier 25MHz - 4GHz                AMF-2D-100M4G-35-10P     379418            Miteq                    12 M          1c           30.06.2017
291         high pass filter GSM 850/900              WHJ 2200-4EE             14                Wainwright GmbH          12 M          1c           30.06.2017
298         Univ. Radio Communication Tester          CMU 200                  832221/091        Rohde & Schwarz          pre-m         3
300         AC LISN (50 Ohm/50µH, 1-phase)            ESH3-Z5                  892 239/020       Rohde & Schwarz          12 M          -            30.05.2017
301         attenuator (20 dB) 50W, 18GHz             47-20-33                 AW0272            Lucas Weinschel          pre-m         2
302         horn antenna 40 GHz (Meas 1)              BBHA9170                 155               Schwarzbeck              36 M          -            31.03.2017
303         horn antenna 40 GHz (Subst 1)             BBHA9170                 156               Schwarzbeck              36 M          -            31.03.2017
331         Climatic Test Chamber -40/+80 Grad        HC 4055                  43146             Heraeus Vötsch           Pre-m         2
341         Digital Multimeter                        Fluke 112                81650455          Fluke                    24 M          -            30.05.2018
342         Digital Multimeter                        Voltcraft M-4660A        IB 255466         Voltcraft                24 M          -            30.04.2017
347         laboratory site                           radio lab.               -                 -                        -             5
348         laboratory site                           EMI conducted            -                 -                        -             5
354         DC - Power Supply 40A                     NGPE 40/40               448               Rohde & Schwarz          pre-m         2
355         Power Meter                               URV 5                    891310/027        Rohde & Schwarz          24 M          -            30.05.2018
357         power sensor                              NRV-Z1                   861761/002        Rohde & Schwarz          24 M          -            30.04.2017
371         Bluetooth Tester                          CBT32                    100153            R&S                      36 M          -            30.05.2019
373         Single-Line V-Network (50 Ohm/5µH)        ESH3-Z6                  100535            Rohde & Schwarz          12 M          -            30.05.2017
377         EMI Test Receiver                         ESCS 30                  100160            Rohde & Schwarz          12 M          -            30.05.2017
389         Digital Multimeter                        Keithley 2000            0583926           Keithley                 24 M          -            30.04.2017
392         Radio Communication Tester                MT8820A                  6K00000788        Anritsu                  12 M          -            30.05.2017
431         Model 7405                                Near-Field Probe Set     9305-2457         EMCO                     -             4
436         Univ. Radio Communication Tester          CMU 200                  103083            Rohde & Schwarz          12 M          -            30.04.2017
439         UltraLog-Antenna                          HL 562                   100248            Rohde & Schwarz          36 M          -            31.03.2017
                                                      System CTC-FAR-EMI-                        ETS-Lindgren /
443         CTC-FAR-EMI-RSE                                                    -                                          12 M          5            30.06.2017
                                                      RSE                                        CETECOM
                                                      WRCT 1850.0/2170.0-                        Wainwright Instruments
448         notch filter WCDMA_FDD II                                          5                                          12 M          1c           30.06.2017
                                                      5/40-                                      GmbH
                                                      WRCT 824.0/894.0-5/40-
449         notch filter WCDMA FDD V                                           1                 Wainwright               12 M          1c           30.06.2017
                                                      8SSK
454         Oscilloscope                              HM 205-3                 9210 P 29661      Hameg                    -             4
456         DC-Power supply 0-5 A                     EA 3013 S                207810            Elektro Automatik        pre-m         2


CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 18 of 19
 Ref.-No.




                                                                                                                                  calibration
                                                                                                                                  Interval of



                                                                                                                                                    Remark
                             Equipment                           Type                     Serial-No.              Manufacturer                                   Cal
                                                                                                                                                                 due

459         DC -Power supply 0-5 A , 0-32 V           EA-PS 2032-50               910722                  Elektro Automatik       pre-m         2
460         Univ. Radio Communication Tester          CMU 200                     108901                  Rohde & Schwarz         12 M          -            30.04.2017
463         Universal source                          HP3245A                     2831A03472              Agilent                 -             4
466         Digital Multimeter                        Fluke 112                   89210157                Fluke USA               24 M          -            30.05.2018
467         Digital Multimeter                        Fluke 112                   89680306                Fluke USA               36 M          -            30.04.2018
468         Digital Multimeter                        Fluke 112                   90090455                Fluke USA               36 M          -            30.04.2018
477         ReRadiating GPS-System                    AS-47                       -                       Automotive Cons. Fink   -             3
480         power meter (Fula)                        NRVS                        838392/031              Rohde & Schwarz         24 M          -            30.04.2017
482         filter matrix                             Filter matrix SAR 1         -                       CETECOM (Brl)           -             1d
                                                      AMF-5D-02501800-25-
484         pre-amplifier 2,5 - 18 GHz                                            1244554                 Miteq                   12 M          -            30.06.2017
                                                      10P
                                                      System EMI field (SAR)                              ETS Lindgren /
487         System CTC NSA-Verification SAR-EMI                                   -                                               24 M          -            31.07.2017
                                                      NSA                                                 CETECOM
489         EMI Test Receiver                         ESU40                       1000-30                 Rohde & Schwarz         12 M          -            30.05.2017
                                                      WRCG 1709/1786-
502         band reject filter                                                    SN 9                    Wainwright              pre-m         2
                                                      1699/1796-
503         band reject filter                        WRCG 824/849-814/859-       SN 5                    Wainwright              pre-m         2
                                                      WRCA 800/960-02/40-
512         notch filter GSM 850                                                  SN 24                   Wainwrght               12 M          1c           30.06.2017
                                                      6EEK
517         relais switch matrix                      HF Relais Box Keithley      SE 04                   Keithley                pre-m         2
523         Digital Multimeter                        L4411A                      MY46000154              Agilent                 24 M          -            30.04.2017
529         6 dB Broadband resistive power divider    Model 1515                  LH 855                  Weinschel               pre-m         2
530         10 dB Broadband resistive power divider   R 416110000                 LOT 9828                -                       pre-m         2
546         Univ. Radio Communication Tester          CMU 200                     106436                  R&S                     12 M          -            30.05.2017
547         Univ. Radio Communication Tester          CMU 200                     835390/014              Rohde & Schwarz         12 M          -            30.04.2017
549         Log.Per-Antenna                           HL025                       1000060                 Rohde & Schwarz         36/12 M       -            31.07.2018
            System CTC S-VSWR Verification SAR-       System EMI Field SAR S-                             ETS
550                                                                               -                                               24 M          -            31.07.2017
            EMI                                       VSWR                                                Lindgren/CETECOM
552         high pass filter 2,8-18GHz                WHKX 2.8/18G-10SS           4                       Wainwright              12 M          1c           30.06.2017
557         System CTC-OTA-2                          R&S TS8991                  -                       Rohde & Schwarz         12 M          5            30.09.2016
                                                      System CTC FAR S-
558         System CTC FAR S-VSWR                                                 -                       CTC                     24 M          -            19.04.2017
                                                      VSWR
574         Biconilog Hybrid Antenna                  BTA-L                       980026L                 Frankonia               36/12 M       -            31.03.2019
584         Spectrum Analyzer                         FSU 8                       100248                  Rohde & Schwarz         pre-m         -
594         Wideband Radio Communication Tester       CMW 500                     101757                  Rohde & Schwarz         12 M          -            30.04.2017
597         Univ. Radio Communication Tester          CMU 200                     100347                  Rohde & Schwarz         pre-m         -
598         Spectrum Analyzer                         FSEM 30 (Reserve)           831259/013              Rohde & Schwarz         24 M          -            30.04.2017
600         power meter                               NRVD (Reserve)              834501/018              Rohde & Schwarz         24 M          -            30.04.2017
601         medium-sensitivity diode sensor           NRV-Z5 (Reserve)            8435323/003             Rohde & Schwarz         24 M          -            30.04.2017
602         peak power sensor                         NRV-Z32 (Reserve)           835080                  Rohde & Schwarz         24 M          -
611         DC power supply                           E3632A                      KR 75305854             Agilent                 pre-m         2
612         DC power supply                           E3632A                      MY 40001321             Agilent                 pre-m         2
613         Attenuator                                R416120000 20dB 10W         Lot. 9828               Radiall                 pre-m         2
616         Digitalmultimeter                         Fluke 177                   88900339                Fluke                   24 M          -            30.05.2018
617         Power Splitter/Combiner                   ZFSC-2-2-S+                 S F987001108            Mini Circuits           -             2
618         Power Splitter/Combiner                   50PD-634                    600994                  JFW Industries USA      -             2
619         Power Splitter/Combiner                   50PD-634                    600995                  JFW Industries, USA     -             3
620         EMI Test Receiver                         ESU 26                      100362                  Rohde-Schwarz           12 M          -            30.05.2017
621         Step Attenuator 0-139 dB                  RSP                         100017                  Rohde & Schwarz         pre-m         2
625         Generic Test Load USB                     Generic Test Load USB       -                       CETECOM                 -             2
                                                                                  201.0999.9302.6.4.1.4
627         data logger                               OPUS 1                                              G. Lufft GmbH           24 M          -            30.04.2017
                                                                                  3
634         Spectrum Analyzer                         FSM (HF-Unit)               826188/010              Rohde & Schwarz         pre-m         2
                                                      HDMI cable with Ethernet
637         High Speed HDMI with Ethernet 1m                                      -                       KogiLink                -             2
                                                      1m
638         HDMI Kabel with Ethernet 1,5 m flach      HDMI cable with Ethernet    -                       Reichelt                -             2
640         HDMI cable 2m rund                        HDMI cable 2m rund          -                       Reichelt                -             2
641         HDMI cable with Ethernet                  Certified HDMI cable with   -                       PureLink                -             2
644         Amplifierer                               ZX60-2534M+                 SN865701299             Mini-Circuits           -             -
670         Univ. Radio Communication Tester          CMU 200                     106833                  Rohde & Schwarz         24 M          -            30.05.2018
671         DC-power supply 0-5 A                     EA-3013S                    -                       Elektro Automatik       pre-m         2
678         Power Meter                               NRP                         101638                  Rohde&Schwarz           pre-m         -
683         Spectrum Analyzer                         FSU 26                      200571                  Rohde & Schwarz         12 M          -            30.05.2017
                                                                                                          Narda Safety Test
686         Field Analyzer                            EHP-200A                    160WX30702                                      24 M          -            30.04.2017
                                                                                                          Solutions
687         Signal Generator                          SMF 100A                    102073                  Rohde&Schwarz           12 M          -            30.05.2017
688         Pre Amp                                   JS-18004000-40-8P           1750117                 Miteq                   pre-m         -
690         Spectrum Analyzer                         FSU                         100302/026              Rohde&Schwarz           12 M          -            30.05.2017
692         Bluetooth Tester                          CBT 32                      100236                  Rohde & Schwarz         36 M          -            31.03.2017
697         Power Splitter                            ZN4PD-642W-S+               165001445               Mini-Circuits           -             2




CETECOM_TR_16_1_0088301T01a


Test Report 16-1-0088301T01a, Page 19 of 19



8.1.3. Legend
Note / remarks                       Calibrated during system calibration:
                           1a        System CTC-SAR-EMS (Ref.-No. 442)
                           1b        System-CTC-EMS-Conducted (Ref.-No. 335)
                           1c        System CTC-FAR-EMI-RSE (Ref.-No . 443)
                           1d        System CTC-SAR-EMI (Ref.-No . 441)
                           1e        System CTC-OATS (EMI radiated) (Ref.-No. 337)
                           1f        System CTC-CTIA-OTA (Ref.-No . 420)
                           1g        System CTC-FAR-EMS (Ref.-No . 444)
                           2         Calibration or equipment check immediately before measurement
                           3         Regulatory maintained equipment for functional check or support purpose
                           4         calibration of this equipment
                                     Ancillary equipment   without has no effect
                                                                   calibration   onmechanical
                                                                               e.g. measuring result
                                                                                              equipment or monitoring equipment
                           5         Test System


Interval of calibration    12 M      12 month
                           24 M      24 month
                           36 M      36 month
                           24/12 M   Calibration every 24 months, between this every 12 months internal validation
                           36/12 M   Calibration every 36 months, between this every 12 months internal validation
                           Pre-m     Check before starting the measurement
                           -         Without calibration




9. Versions of test reports (change history)

      Version             Applied changes                                                                                     Date of release
        --                Initial release                                                                                      2016-06-21
        --                --                                                                                                        --