RF Exposure Info

FCC ID: XPB-LE

RF Exposure Info

Download: PDF
FCCID_3238458

                                                           Willow Run Test Labs, LLC
                                                           8501 Beck Road, Building 2227
                                                           Belleville, MI 48111
                                                           Phone: (734) 252-9785, Fax (734) 926-9785
                                                           e-mail: info@wrtest.com




                                                                           RF EXPOSURE CALCULATIONS

    Requirement:
    According to USA CFR 15 §1.1307 (b)(1), systems operating under the provisions of this section
    shall be operated in a manner that ensures the public is not exposed to radio frequency energy
    level in excess of the Commission’s guidelines. For Canada, RSS-102 sets out the requirements
    and measurement techniques used to evaluate radio frequency (RF) exposure compliance of
    radiocommunication apparatus designed to be used within the vicinity of the human body.

    Maximum Permissible Exposure Calculations:


          USA REF: 1.1310, 2.1091/1093, 447498 D01 General RF Exposure Guidance v06                                                                         Test Date:                                 25-Oct-16
            IC REF: RSS-102 Issue 5, Safety Code 6                                                                                                      Test Engineer:                               Joseph Brunett
  Min. Sep. Distance: 20 cm (Mobile)                                                                                                                             EUT:                                 Allegion LE
                                                                                                                                                          EUT Mode:                                    Worst Case
                                                                                                                                                       Meas. Distance:                                  3 meters


                                                                                                                            Canada ISED RSS-102 MPE                                       USA FCC 1.1310 MPE
        Mode               Freq.          Worst Case E3(Avg)*       E20cm(Avg)        H20cm(Avg)        SC6 Limit (E20cm)     SC6 Limit (H20cm) Worst Case MPE Ratio     E20cm Limit***   H20cm Limit*** Worst Case MPE Ratio
                           MHz                  dBuV/m                dBuV/m           dBuA/m               dBuV/m                 dBuA/m                                   dBuV/m           dBuA/m
       LF Entry           0.12500              56.90000              103.94365        52.64365                                   135.32826            0.00007              175.76337        124.24375           0.00026
       LF Entry          13.56000              54.80000              101.84365        50.54365                148.77401           97.24263            0.00462              155.67335        104.16369           0.00208
        Mode               Freq.        Worst Case EIRP(Avg)**      E20cm(Avg)     S20cm(Avg)****                             SC6 Limit (S20cm)      MPE Ratio                               S Limit          MPE Ratio
                           MHz                   dBm                  dBuV/m          mW/cm2                                      mW/cm2                                                     mW/cm2
   BLE (module)         2400-2483.5             11.15000             129.87183          0.00259                                   5.47422              0.00047                               1.00000            0.00259
  WiLAN (module)        2400-2483.5             16.54000             135.26183          0.00897                                   5.47422              0.00164                               1.00000            0.00897
                                                                                                                                MPE Total (<1):         .007                              MPE Total (<1):             .014
                                                                                                                                     Complies?          Yes                                    Complies?              Yes
*As Measured / Computed from highest fundamental emission, see fundamental emission section of this report.
**EIRP, as computed from Modular Device RF Exposure Exhibits.
*** For FCC MPE, use of 300 kHz limit at 125 kHz as previously allowed by FCC.
**** EIRP (mW) = S (mW/cm^2) x 4 x PI x 20cm^2




    Summary:
    The EUT with all transmitters is compliant with both the FCC power density limit and the ISED
    Exposure Evaluation limits.



Document Created: 2016-12-22 14:29:58
Document Modified: 2016-12-22 14:29:58

© 2024 FCC.report