RF Exposure

FCC ID: XN6-SB3830C6M

RF Exposure Info

Download: PDF
FCCID_2526714

                       RF Exposure evaluation


According to KDB 447498 D01 General RF Exposure Guidance v05
The 1-g and 10-g SAR test exclusion thresholds for 100 MHz to 6 GHz at
test separation distances ≤ 50 mm are determined by:
[(max. power of channel, including tune-up tolerance, mW)/(min. test
separation distance, mm)] ·[√f(GHz)] ≤ 3.0 for 1-g SAR and ≤ 7.5 for
10-g extremity SAR, where
  f(GHz) is the RF channel transmit frequency in GHz
   Power and distance are rounded to the nearest mW and mm before
calculation
  The result is rounded to one decimal place for comparison


Worse case is as below: [2402MHz 8.012dBm(6.327 mW) output power]


(6.327mW /5mm) ·[√2.402 (GHz)]=    1.96 <3.0 for 1-g SAR


Then SAR evaluation is not required



Document Created: 2015-02-07 11:45:49
Document Modified: 2015-02-07 11:45:49