FCC MPE

FCC ID: XMR201910BG95M3

RF Exposure Info

Download: PDF
FCCID_4471789

                            MPE TEST REPORT

            Applicant             Quectel Wireless Solutions Co., Ltd

            FCC ID                XMR201910BG95M3

            Product               LTE Cat M1 & Cat NB2 & EGPRS Module

            Brand                 Quectel

            Marketing             Quectel BG95-M3

            Model                 BG95-M3

            Report No.            R1907A0446-M1

            Issue Date            September 12, 2019


TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC
47 CFR Part 1 1.1310. The test results show that the equipment tested is capable of demonstrating compliance
with the requirements as documented in this report.




                    Performed by: Yu Wang                 Approved by: Guangchang Fan




               TA Technology (Shanghai) Co., Ltd.
                  No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China
                                        TEL: +86-021-50791141/2/3
                                     FAX: +86-021-50791141/2/3-8000


           MPE Test Report                                                                                      Report No.: R1907A0446‐M1




                                                     Table of Contents
1  Test Laboratory............................................................................................................................... 3
 1.1    Notes of the Test Report ......................................................................................................... 3
 1.2    Test facility .............................................................................................................................. 3
 1.3    Testing Location ...................................................................................................................... 4
 1.4    Laboratory Environment .......................................................................................................... 4
2 Description of Equipment under Test .............................................................................................. 5
3 Maximum conducted output power (measured) and antenna Gain ................................................ 6
4 Test Result ..................................................................................................................................... 8




TA Technology (Shanghai) Co., Ltd.                                                                                 Page 2 of 12
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


         MPE Test Report                                                                        Report No.: R1907A0446‐M1




1 Test Laboratory

1.1 Notes of the Test Report

This report shall not be reproduced in full or partial, without the written approval of TA technology

(shanghai) co., Ltd.The results documented in this report apply only to the tested sample, under the

conditions and modes of operation as described herein .Measurement Uncertainties were not taken

into account and are published for informational purposes only. This report is written to support

regulatory compliance of the applicable standards stated above.


1.2 Test facility

FCC (Designation number: CN1179, Test Firm Registration Number: 446626)
TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission
list of test facilities recognized to perform electromagnetic emissions measurements.
IC (recognition number is 8510A)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic
emission measurement.
VCCI (recognition number is C-4595, T-2154, R-4113, G-10766)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic
emission measurement.
A2LA (Certificate Number: 3857.01)
TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory
Accreditation to perform electromagnetic emission measurement.




TA Technology (Shanghai) Co., Ltd.                                                                                 Page 3 of 12
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           MPE Test Report                                                                      Report No.: R1907A0446‐M1


1.3 Testing Location


   Company:             TA Technology (Shanghai) Co., Ltd.

   Address:             No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China

   City:                Shanghai

   Post code:           201201
   Country:             P. R. China

   Contact:             Xu Kai

   Telephone:           +86-021-50791141/2/3

   Fax:                 +86-021-50791141/2/3-8000
   Website:             http://www.ta-shanghai.com

   E-mail:              xukai@ta-shanghai.com




1.4 Laboratory Environment

   Temperature                                             Min. = 18C, Max. = 25 C

   Relative humidity                                       Min. = 30%, Max. = 70%

   Ground system resistance                                < 0.5 
   Ambient noise is checked and found very low and in compliance with requirement of standards.
   Reflection of surrounding objects is minimized and in compliance with requirement of standards.




TA Technology (Shanghai) Co., Ltd.                                                                                 Page 4 of 12
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


         MPE Test Report                                                                        Report No.: R1907A0446‐M1


2 Description of Equipment under Test

 Client Information
   Applicant                           Quectel Wireless Solutions Co., Ltd
                                       Building 5, Shanghai Business Park Phase III (Area B), No.1016
   Applicant address
                                       Tianlin Road, Minhang District, Shanghai, China 200233
   Manufacturer                        Quectel Wireless Solutions Co., Ltd
                                       Building 5, Shanghai Business Park Phase III (Area B), No.1016
   Manufacturer address
                                       Tianlin Road, Minhang District, Shanghai, China 200233


General Technologies
   Model                               BG95-M3
   SN                                  864475040001835
   Hardware Version                    R2.1
   Software Version                    BG95M3LAR02A01
   Date of Testing:                    August 20, 2019 ~ September 5, 2019




TA Technology (Shanghai) Co., Ltd.                                                                                 Page 5 of 12
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


         MPE Test Report                                                                        Report No.: R1907A0446‐M1


3 Maximum conducted output power (measured) and antenna Gain

The numeric gain (G) of the antenna with a gain specified in dB is determined by
Numeric gain (G)=10^(antenna gain/10)
                                                Burst Turn up             Division           Time-Averaged Tune up
                 Band
                                                Power(dBm)              Factors (dB)              Power (dBm)
    GSM850                  GSM                     35.000                   -9.03                       25.97
   GSM1900                  GSM                     32.000                   -9.03                       22.97
Note:
Division Factors
       To average the power, the division factor is as follows:
       1Txslot = 1 transmit time slot out of 8 time slots
                  => conducted power divided by (8/1) => -9.03 dB
       2Txslots = 2 transmit time slots out of 8 time slots
                  => conducted power divided by (8/2) => -6.02 dB
       3Txslots = 3 transmit time slots out of 8 time slots
                  => conducted power divided by (8/3) => -4.26 dB
       4Txslots = 4 transmit time slots out of 8 time slots
                  => conducted power divided by (8/4) => -3.01 dB




                                                           Maximum Conducted Output Power (dBm)
                     Band
                                                              (dBm)                                  (mW)
                  GSM850                                     25.970                                395.367
                 GSM1900                                     22.970                                198.153
                LTE Band 2                                   22.000                                158.489
                LTE Band 4                                   22.000                                158.489
                LTE Band 5                                   22.000                                158.489
                LTE Band 12                                  22.000                                158.489
                LTE Band 13                                  22.000                                158.489
                LTE Band 14                                  22.000                                158.489
                LTE Band 25                                  22.000                                158.489
                LTE Band 26                                  22.000                                158.489
                LTE Band 66                                  22.000                                158.489
                LTE Band 85                                  22.000                                158.489
              NB-IOT Band 2                                  22.000                                158.489
              NB-IOT Band 4                                  22.000                                158.489

TA Technology (Shanghai) Co., Ltd.                                                                                 Page 6 of 12
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


         MPE Test Report                                                                        Report No.: R1907A0446‐M1

              NB-IOT Band 5                                  22.000                                158.489
             NB-IOT Band 12                                  22.000                                158.489
             NB-IOT Band 13                                  22.000                                158.489
             NB-IOT Band 25                                  22.000                                158.489
             NB-IOT Band 26                                  22.000                                158.489
             NB-IOT Band 66                                  22.000                                158.489
             NB-IOT Band 71                                  22.000                                158.489
             NB-IOT Band 85                                  22.000                                158.489




TA Technology (Shanghai) Co., Ltd.                                                                                 Page 7 of 12
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


         MPE Test Report                                                                        Report No.: R1907A0446‐M1


4 Test Result

    According to section 1.1310 of FCC 47 CFR Part 1, limits for maximum permissible exposure

    (MPE) are as following




Note1. Occupational/controlled limits apply in situations in which persons are exposed as a
consequence of their employment provided those persons are fully aware of the potential for
exposure and can exercise control over their exposure. Limits for occupational/controlled exposure
also apply in situations when an individual is transient through a location where occupational /
controlled limits apply provided he or she is made aware of the potential for exposure.

Note2: General population/uncontrolled exposures apply in situations in which the general public may
be exposed, or in which persons that are exposed as a consequence of their employment may not be
fully aware of the potential for exposure or can not exercise control over their exposure.




TA Technology (Shanghai) Co., Ltd.                                                                                 Page 8 of 12
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


         MPE Test Report                                                                        Report No.: R1907A0446‐M1
   The maximum permissible exposure for 300~1500 MHz is f/1500, for 1500~100,000MHz is 1.0.So

                        Band                             The maximum permissible exposure (mW/cm2)
                      GSM850                                                         0.566
                     GSM1900                                                         1.000
                    LTE Band 2                                                       1.000
                    LTE Band 4                                                       1.000
                    LTE Band 5                                                       0.566
                   LTE Band 12                                                       0.477
                   LTE Band 13                                                       0.525
                   LTE Band 14                                                       0.532
                   LTE Band 25                                                       1.000
                   LTE Band 26                                                       0.566
                   LTE Band 66                                                       1.000
                   LTE Band 85                                                       0.477
                  NB-IOT Band 2                                                      1.000
                  NB-IOT Band 4                                                      1.000
                  NB-IOT Band 5                                                      0.566
                 NB-IOT Band 12                                                      0.477
                 NB-IOT Band 13                                                      0.525
                 NB-IOT Band 25                                                      1.000
                 NB-IOT Band 26                                                      0.566
                 NB-IOT Band 66                                                      1.000
                 NB-IOT Band 71                                                      0.465
                 NB-IOT Band 85                                                      0.477




TA Technology (Shanghai) Co., Ltd.                                                                                 Page 9 of 12
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


         MPE Test Report                                                                        Report No.: R1907A0446‐M1
                          Maximum
                          Conducted            EIRP                      Power density Limit
                                                           Margin1                                     Margin2        Final
        Band               Output              limit
                                                            (dB)                                        (dB)         Margin
                            Power             (dBm)                      (mW/cm2)          (dBm)                      (dB)
                            (dBm)
      GSM850                 25.970           40.600        14.630          0.566         34.541         8.571        8.571

     GSM1900                 22.970           33.000        10.030          1.000         37.013        14.043       10.030

    LTE Band 2               22.000           33.000        11.000          1.000         37.013        15.013       11.000

    LTE Band 4               22.000           30.000         8.000          1.000         37.013        15.013        8.000

    LTE Band 5               22.000           40.600        18.600          0.566         34.541        12.541       12.541

   LTE Band 12               22.000           36.920        14.920          0.477         33.798        11.798       11.798

   LTE Band 13               22.000           36.920        14.920          0.525         34.214        12.214       12.214

   LTE Band 14               22.000           36.920        14.920          0.532         34.272        12.272       12.272

   LTE Band 25               22.000           33.000        11.000          1.000         37.013        15.013       11.000

   LTE Band 26               22.000           40.600        18.600          0.566         34.541        12.541       12.541

   LTE Band 66               22.000           30.000         8.000          1.000         37.013        15.013        8.000
   LTE Band 85               22.000           36.920        14.920          0.477         33.798        11.798       11.798
  NB-IOT Band 2              22.000           33.000        11.000          1.000         37.013        15.013       11.000
  NB-IOT Band 4              22.000           30.000         8.000          1.000         37.013        15.013        8.000
  NB-IOT Band 5              22.000           40.600        18.600          0.566         34.541        12.541       12.541
 NB-IOT Band 12              22.000           36.920        14.920          0.477         33.798        11.798       11.798
 NB-IOT Band 13              22.000           36.920        14.920          0.525         34.214        12.214       12.214
 NB-IOT Band 25              22.000           33.000        11.000          1.000         37.013        15.013       11.000
 NB-IOT Band 26              22.000           40.600        18.600          0.566         34.541        12.541       12.541
 NB-IOT Band 66              22.000           30.000         8.000          1.000         37.013        15.013        8.000
 NB-IOT Band 71              22.000           36.920        14.920          0.465         33.687        11.687       11.687
 NB-IOT Band 85              22.000           36.920        14.920          0.477         33.798        11.798       11.798
Note: 1. The Maximum allowed antenna gain per Band should be less than or equal to the Final
Margin which is the allowable maximum gain value to comply with limits for maximum permissible
exposure (MPE).
2. The Final Margin is determined and selected to the worst-case of Margin1 and Margin2.
3. Margin1=EIRP Limit(dBm)-Maximum Conducted Power (dBm). EIRP limit reference standard
part22/ part24/part27and part90 for each band, EIRP = ERP + 2.15 (dB).
4. Margin2=Power density Limit(dBm)-Maximum Conducted Power (dBm). Power density
Limit(dBm): The max. obtained by MPE with 20cm.

TA Technology (Shanghai) Co., Ltd.                                                                                Page 10 of 12
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          MPE Test Report                                                                        Report No.: R1907A0446‐M1



IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, the
antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20
cm from all persons and must not be co-located or operating in conjunction with any other antenna
or transmitter. No change to the antenna or the device is permitted. Any change to the antenna or
the device could result in the device exceeding the RF exposure requirements and void user’s
authority to operate the device.




 TA Technology (Shanghai) Co., Ltd.                                                                                Page 11 of 12
 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          MPE Test Report                                                                        Report No.: R1907A0446‐M1


 RF Exposure Calculations:
 The following information provides the minimum separation distance for the highest gain antenna
 provided. This calculation is based on the conducted power, considering maximum power and
 antenna gain. The formula shown in KDB 447498 D01 is used in the calculation.
 Equation from KDB 447498 D01 General RF Exposure Guidance v06 (10/23/2015) is:
                                                                       2
                                                       S= PG / 4∏R
                                                                            2
 Where: S = power density (in appropriate units, e.g. mW/cm )
        P = Time-average maximum tune up procedure (in appropriate units, e.g., mW)
        G = the numeric gain of the antenna
        R = distance to the center of radiation of the antenna (20 cm = limit for MPE)
                                                                Test Result            Limit Value
               Band                        PG (mW)                          2                      2          Conclusion
                                                                 (mW/cm )               (mW/cm )
             GSM850                        2845.116                0.566                  0.566                   Pass
            GSM1900                        1995.262                 0.397                  1.000                  Pass
           LTE Band 2                      1995.262                 0.397                  1.000                  Pass
           LTE Band 4                      1000.000                 0.199                  1.000                  Pass
           LTE Band 5                      2845.116                 0.566                  0.566                  Pass
          LTE Band 12                      2397.728                 0.477                  0.477                  Pass
          LTE Band 13                      2638.761                 0.525                  0.525                  Pass
          LTE Band 14                      2674.238                 0.532                  0.532                  Pass
          LTE Band 25                      1995.262                 0.397                  1.000                  Pass
          LTE Band 26                      2845.116                 0.566                  0.566                  Pass
          LTE Band 66                      1000.000                 0.199                  1.000                  Pass
          LTE Band 85                      2397.728                 0.477                  0.477                  Pass
        NB-IOT Band 2                      1995.262                 0.397                  1.000                  Pass
        NB-IOT Band 4                      1000.000                 0.199                  1.000                  Pass
        NB-IOT Band 5                      2845.116                 0.566                  0.566                  Pass
        NB-IOT Band 12                     2397.728                 0.477                  0.477                  Pass
        NB-IOT Band 13                     2638.761                 0.525                  0.525                  Pass
        NB-IOT Band 25                     1995.262                 0.397                  1.000                  Pass
        NB-IOT Band 26                     2845.116                 0.566                  0.566                  Pass
        NB-IOT Band 66                     1000.000                 0.199                  1.000                  Pass
        NB-IOT Band 71                     2337.222                 0.465                  0.465                  Pass
        NB-IOT Band 85                     2397.728                 0.477                  0.477                  Pass
 Note: R = 20cm
      ∏= 3.1416
Note: For transmitters, minimum separation distance is 20cm, even if calculations indicate MPE
      distance is less.




 TA Technology (Shanghai) Co., Ltd.                                                                                Page 12 of 12
 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.



Document Created: 2019-10-17 12:23:45
Document Modified: 2019-10-17 12:23:45

© 2024 FCC.report