            Applicant / Grantee                           Quectel Wireless Solutions Company Limited
            FCC ID:                                       XMR201907EG91VX
            Model:                                        EG91-VX

          The single module transmitter has been evaluated then tested meeting the
          requirements under Part 15C Section 212 as below:

 Modular approval requirement                                                                       EUT Condition                                        Comply
(a) The radio elements of the modular transmitter must have                                  The radio elements of the modular                           YES
    their own shielding. The physical crystal and tuning                                    transmitter have their own shielding.
    capacitors may be located external to the shielded radio
    elements.

(b)       The       modular       transmitter     must       have                           The modular has buffered data                                YES
      buffered modulation/data inputs (if such inputs are                                   inputs, it is integrated in chip. Please
      provided) to ensure that the module will comply with part 15                          see schematic.pdf
      requirements under conditions of excessive data rates or
      over-modulation.

(c)The modular transmitter must have its                                                    All power lines derived from the host                        YES
 own power supply regulation.                                                               device are regulated before
                                                                                            energizing other circuits internal to
                                                                                            the EG91-VX. Please see
                                                                                            schematic.pdf
(d)        The       modular      transmitter     must       comply                         A permanently attached antenna or                            YES
       with the antenna and transmission system requirements of                             unique antenna connector is not a
      Sections 15.203, 15.204(b) and 15.204(c). The antenna                                 requirement for licensed modules.
      must either be permanently attached or employ a “unique”
      antenna coupler (at all connections between the module and
      the antenna, including the cable). The “professional
      installation” provision of Section 15.203 is not applicable to
      modules but can apply to limited modular approvals under
      paragraph (b) of this section.

(e)The      modular      transmitter       must    be     tested                            The EG91-VX was tested in a                                  YES
    in a stand-alone configuration, i.e., the module must not be                            stand‐alone configuration via a
   inside another device during testing for compliance with part                            PCMCIA extender. Please see
   15 requirements. Unless the transmitter module will be                                   spurious set‐up
   battery powered, it must comply with the AC line conducted
   requirements found in Section 15.207. AC or DC power lines
   and data input/output lines connected to the module must
   not contain ferrites, unless they will be marketed with the

         7th Floor, Hongye Building, No.1801 Hongmei Road, Xuhui District, Shanghai 200233, ChinaEmail: info@quectel.comWebsite: www.quectel.compage 1


       Quectel Wireless Solutions Company Limited

   module (see Section 15.27(a)). The length of these lines
   shall be the length typical of actual use or, if that length is
   unknown, at least 10 centimeters to insure that there is no
   coupling between the case of the module and supporting
   equipment. Any accessories, peripherals, or support
   equipment connected to the module during testing shall be
   unmodified and commercially available (see Section
   15.31(i))mustnotbeinsideanotherdeviceduringtesting.

(f)The         modular        transmitter      must        be                             The label position of EG91-VX is                             YES
      equipped with either a permanently affixed label or must                            clearly indicated. If the FCC ID of the
     be capable of electronically displaying its FCC
     identification number.                                                               module cannot be seen when it is
                                                                                          installed, then the host label must
                                                                                          include the text: Contains FCC ID:
                                                                                          XMR201907EG91VX. Please see the
                                                                                          label.pdf
(g) The modular transmitter must comply                                                   The EG91-VX is compliant with all                            YES
    with any specific rules or operating requirements that                                applicable FCC rules. Detail
    ordinarily apply to a complete transmitter and the                                    instructions are given in the User
    manufacturer must provide adequate instructions along                                 Manual.
    with the module to explain any suchrequirements. A copy
    of these instructions must be included in the application for
    equipmentauthorizationrequirements,whicharebasedonthei
    ntendeduse/configurations.

(h)The modular transmitter must comply                                                    The EG91-VX is approved to comply                            YES
   with any applicable RF exposure requirements in its final                              with the applicable RF exposure
   configuration.                                                                         requirement, please see the MPE
                                                                                          evaluation with 20cm as the distance
                                                                                          restriction.




       ___________________________________

       Johnny Xiang

       Quectel Wireless Solutions Company Limited

       Tel: +8602150086326

       Fax: +862153253668

       E-mail: johnny.xiang@quectel.com

       7th Floor, Hongye Building, No.1801 Hongmei Road, Xuhui District, Shanghai 200233, ChinaEmail: info@quectel.comWebsite: www.quectel.compage 2



Document Created: 2019-06-20 15:19:23
Document Modified: 2019-06-20 15:19:23

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC