MPE report

FCC ID: XMR201903EG25G

RF Exposure Info

Download: PDF
FCCID_4219743

                 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
                 Branch

                                                                                  Report No.: HR/2019/1001602
                                                                                  Page:       1 of 7

                            Cover P   RF Exposure Evaluation Report
Application No.:                      HR/2019/10016
Applicant:                            Quectel Wireless Solutions Co., Ltd.
Address of Applicant:                 7th Floor, Hongye Building, No.1801 Hongmei Road, Xuhui District,
                                      Shanghai 200233, China
Manufacturer:                         Quectel Wireless Solutions Co., Ltd.
Address of Manufacturer:              7th Floor, Hongye Building, No.1801 Hongmei Road, Xuhui District,
                                      Shanghai 200233, China
Factory:                              Quectel Wireless Solutions Co., Ltd.
Address of Factory:                   7th Floor, Hongye Building, No.1801 Hongmei Road, Xuhui District,
                                      Shanghai 200233, China
EUT Description:                      LTE Module
Model No.:                            EG25-G, EG25-G MINIPCIE
Trade Mark:                           Quectel
FCC ID:                               XMR201903EG25G
Standards:                            47 CFR Part 2
                                      47 CFR Part 22 subpart H
                                      47 CFR Part 24 subpart E
                                      47 CFR Part 27 subpart C
Date of Receipt:                      2019/1/30
Date of Test:                         2019/1/31 to 2019/2/28
Date of Issue:                        2019/2/28
Test Result:                           PASS*
*      In the configuration tested, the EUT complied with the standards specified above.




    Authorized Signature:




       Derek Yang
Wireless Laboratory Manager


                 SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
                 Branch
                                                                Report No.: HR/2019/1001602
                                                                Page:       2 of 7

1 Version
                                           Revision Record
        Version        Chapter          Date                  Modifier          Remark

            00                          2019/2/28                                  Original




   Authorized for issue by:




                                                                           2019/2/28


                                 Mike Hu /Project Engineer


                                                                           2019/2/28


                                 David Chen /Reviewer


Reamark:
The difference between EG25-G and EG25-G MIMIPCIE:
EG25-G and EG25-G MINIPCIE both are LTE modules(Category: Cat.4). They have the same frequency
and use the same chipset and share the same software & hardware design.
EG25-G MINIPCIE makes up of EG25-G module and PCIe carrier board.No any other internal changes in
EG25-G module. We hereby state that two models are identical in interior structure and components, and
just connector interface is different for the marketing requirement.
According to the difference above, all the tests were performed on EG25-G, and the data of EG25-G
MINIPCIE can refer to EG25-G.


                         SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
                         Branch
                                                                                                                Report No.: HR/2019/1001602
                                                                                                                Page:       3 of 7


                                                                            Contents
1       VERSION ................................................................................................................................................................. 2

2       GENERAL INFORMATION .................................................................................................................................. 4
    2.1          CLIENT INFORMATION ..................................................................................................................................... 4
    2.2          TEST LOCATION .............................................................................................................................................. 4
    2.3          TEST FACILITY ................................................................................................................................................. 4
    2.4          GENERAL DESCRIPTION OF EUT.................................................................................................................... 5
    2.5          TEST MODE ..................................................................................................................................................... 5
3       RF EXPOSURE EVALUATION ........................................................................................................................... 6
    3.1     RF EXPOSURE COMPLIANCE REQUIREMENT ................................................................................................. 6
       3.1.1 Limits .......................................................................................................................................................... 6
       3.1.2 Test Procedure ......................................................................................................................................... 6
       3.1.3 EUT RF Exposure Evaluation ................................................................................................................ 7


                SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
                Branch
                                                                  Report No.: HR/2019/1001602
                                                                  Page:       4 of 7


2      General Information
2.1 Client Information
Applicant:                 Quectel Wireless Solutions Co., Ltd.
                           7th Floor, Hongye Building, No.1801 Hongmei Road, Xuhui District, Shanghai
Address of Applicant:
                           200233, China
Manufacturer:              Quectel Wireless Solutions Co., Ltd.
                           7th Floor, Hongye Building, No.1801 Hongmei Road, Xuhui District, Shanghai
Address of Manufacturer:
                           200233, China
Factory:                   Quectel Wireless Solutions Co., Ltd.
                           7th Floor, Hongye Building, No.1801 Hongmei Road, Xuhui District, Shanghai
Address of Factory:
                           200233, China
2.2 Test Location
Company:                   SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch
                           No. 1 Workshop, M-10, Middle section, Science & Technology Park, Shenzhen,
Address:
                           Guangdong, China
Post code:                 518057
Telephone:                 +86 (0) 755 2601 2053
Fax:                       +86 (0) 755 2671 0594
E-mail:                    ee.shenzhen@sgs.com

2.3 Test Facility
The test facility is recognized, certified, or accredited by the following organizations:
• CNAS (No. CNAS L2929)
CNAS has accredited SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen Branch EMC Lab to
ISO/IEC 17025:2005 General Requirements for the Competence of Testing and Calibration Laboratories
(CNAS-CL01 Accreditation Criteria for the Competence of Testing and Calibration Laboratories) for the
competence in the field of testing.
• A2LA (Certificate No. 3816.01)
SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory is accredited by the
American Association for Laboratory Accreditation(A2LA). Certificate No. 3816.01.
• VCCI
The 3m Fully-anechoic chamber for above 1GHz, 10m Semi-anechoic chamber for below 1GHz, Shielded
Room for Mains Port Conducted Interference Measurement and Telecommunication Port Conducted
Interference Measurement of SGS-CSTC Standards Technical Services Co., Ltd. have been registered in
accordance with the Regulations for Voluntary Control Measures with Registration No.: G-20026, R-14188,
C-12383 and T-11153 respectively.
• FCC –Designation Number: CN1178
SGS-CSTC Standards Technical Services Co., Ltd., Shenzhen EMC Laboratory has been recognized as an
accredited testing laboratory.
Designation Number: CN1178. Test Firm Registration Number: 406779.
• Industry Canada (IC)
Two 3m Semi-anechoic chambers and the 10m Semi-anechoic chamber of SGS-CSTC Standards Technical
Services Co., Ltd. Shenzhen Branch EMC Lab have been registered by Certification and Engineering
Bureau of Industry Canada for radio equipment testing with Registration No.: 4620C-1, 4620C-2, 4620C-3.


                SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
                Branch
                                                                  Report No.: HR/2019/1001602
                                                                  Page:       5 of 7


2.4 General Description of EUT
EUT Description::                   LTE Module
Model No.:                          EG25-G, EG25-G MINIPCIE
Trade Mark:                         Quectel
Hardware Version:                   R1.0
Software Version:                   EG25GGBR07A06M4G
                                    GSM850: 2.29dBi;
                                    GSM1900:1.59dBi
                                    WCDMA BAND II:1.59dBi
                                    WCDMA BAND VI:2dBi
                                    WCDMA BAND V:2.29dBi
                                    LTE BAND 2:1.59dBi;
                                    LTE BAND 4:2dBi;
Antenna Gain:                       LTE BAND 5:2.29dBi;
                                    LTE BAND 7: 3dBi;
                                    LTE BAND 12: 3.26dBi;
                                    LTE BAND 13: 4.45dBi;
                                    LTE BAND 25: 1.59dBi;
                                    LTE BAND 26: 2.53dBi;
                                    LTE BAND 38: 2.06dBi;
                                    LTE BAND 41: 3dBi;
2.5 Test Mode
Test Mode                           Test Modes Description
LTE/TM1                             LTE system, QPSK modulation
LTE/TM2                             LTE system, 16QAM modulation
REMARK: The test mode(s) are selected according to relevant radio technology specifications.


                  SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
                  Branch
                                                                   Report No.: HR/2019/1001602
                                                                   Page:       6 of 7



 3 RF Exposure Evaluation
3.1 RF Exposure Compliance Requirement
3.1.1 Limits
   Frequency range       Electric field strength Magnetic field strength Power density Averaging time
        (MHz)                     (V/m)                  (A/m)             (mW/cm2)      (minutes)

                           (A) Limits for Occupational/Controlled Exposures

         0.3-3.0                  614                     1.63                *(100)             6

         3.0-30                  1842/f                   4.89/f             *(900/f2)           6

         30-300                   61.4                    0.163                 1.0              6

       300-1500                     /                       /                  f/300             6

     1500-100,000                   /                       /                    5               6

                       (B) Limits for General Population/Uncontrolled Exposure

        0.3-1.34                  614                     1.63                *(100)             30

        1.34-30                   824/f                   2.19/f             *(180/f2)           30

         30-300                   27.5                    0.073                 0.2              30

       300-1500                     /                       /                 f/1500             30

     1500-100,000                   /                       /                   1.0              30

F=frequency in MHz
*=Plane-wave equivalent power density
RF exposure compliance will need to be determined with respect to 1.1307(c) and (d) of the FCC rules. The
emissions should be within the limits at 300kHz in Table 1 of 1.1310(use the 300kHz limits for
150kHz:614V/m,1.63A/m).

Friis Formula
Friis transmission formula: Pd = (Pout*G)/(4* Pi * R 2)
Where
Pd = power density in mW/cm2
Pout = output power to antenna in mW
G = gain of antenna in linear scale
Pi = 3.1416
R = distance between observation point and center of the radiator in cm
Pd id the limit of MPE, 1 mW/cm2 . If we know the maximum gain of the antenna and the total power input to
the antenna, through the calculation, we will know the distance r where the MPE limit is reached.
3.1.2 Test Procedure
Software provided by client enabled the EUT to transmit data at lowest, middle and highest channel
individually.


                   SGS-CSTC Standards Technical Services Co., Ltd. Shenzhen
                   Branch
                                                                                                        Report No.: HR/2019/1001602
                                                                                                        Page:       7 of 7




3.1.3 EUT RF Exposure Evaluation
Antenna Gain: The maximum Gain measured in fully anechoic chamber is 2.0 / 2.0 in linear scale.
Output Power Into Antenna & RF Exposure Evaluation Distance:
                                                   Max
                                                           Output                       Power
                                                Conducted                    Output                         Gain
                                      Antenna              Power EIRP(ERP)              Density                        Gain      Max Gain
            Operating       Frequency            Average                      Power                Limit according
                                       Gain                  to     Limit              at R = 20                    according    Allowed    conclusion
              Band            (MHz)               Output                   to Antenna            (mW/cm2) to EIRP
                                       (dBi)              Antenna  (dBm)                  cm                       to Pd (dBi)    (dBi)
                                                  Power                       (mw)                          (dBi)
                                                           (dBm)                      (mW/cm2)
                                                  (dBm)
             GSM850          824.2      2.29      25.81    25.95   38.45    381.0658    0.1284    0.5495   14.79      8.60         8.60       Pass
            GSM1900          1850.2     1.59      22.81    24.40   33.00    190.9853    0.0548    1.0000   10.19      14.20       10.19       Pass
            WCDMA B2         1852.4     1.59      25.00    26.59   33.00    316.2278    0.0907    1.0000    8.00      12.01        8.00       Pass
            WCDMA B4         1712.4     2.00      25.00    27.00   30.00    316.2278    0.0997    1.0000    5.00      12.01        5.00       Pass
            WCDMA B5         826.4      2.29      25.00    25.14   38.45    316.2278    0.1066    0.5509   15.60      9.42         9.42       Pass
              LTE B2         1850.7     1.59      25.00    26.59   33.00    316.2278    0.0907    1.0000    8.00      12.01        8.00       Pass
              LTE B4         1710.7     2.00      25.00    27.00   30.00    316.2278    0.0997    1.0000    5.00      12.01        5.00       Pass
              LTE B5         824.70     2.29      25.00    25.14   38.45    316.2278    0.1066    0.5498   15.60      9.41         9.41       Pass
              LTE B7        2502.50     3.00      25.00    28.00   33.00    316.2278    0.1255    1.0000    8.00      12.01        8.00       Pass
             LTE B12         699.70     3.26      25.00    26.11   34.77    316.2278    0.1333    0.4665   11.92      8.70         8.70       Pass
             LTE B13         779.50     4.45      25.00    27.30   34.77    316.2278    0.1753    0.5197   11.92      9.16         9.16       Pass
             LTE B25         1850.7     1.59      25.00    26.59   33.00    316.2278    0.0907    1.0000    8.00      12.01        8.00       Pass
         LTE B26(814-824)    814.7      2.53      25.00    25.38   50.00    316.2278    0.1126    0.5431   27.15      9.36         9.36       Pass
         LTE B26(824-849)    824.7      2.53      25.00    25.38   38.45    316.2278    0.1126    0.5498   15.60      9.41         9.41       Pass
             LTE B38         2572.5     2.06      25.00    27.06   33.00    316.2278    0.1011    1.0000    8.00      12.01        8.00       Pass
             LTE B41         2498.5     3.00      25.00    28.00   33.00    316.2278    0.1255    1.0000    8.00      12.01        8.00       Pass


Remark: Refer to report No. HR/2019/1001601 for EUT test Max Conducted Output Power value.



Document Created: 2019-03-21 15:49:36
Document Modified: 2019-03-21 15:49:36

© 2024 FCC.report