MPE

FCC ID: XMR201808BC66

RF Exposure Info

Download: PDF
FCCID_4083666

                            MPE TEST REPORT

                 Applicant            Quectel Wireless Solutions Co., Ltd

                 FCC ID               XMR201808BC66

                 Product              NB_IoT Module

                 Brand                Quectel

                 Model                BC66

                 Report No.           R1809A0442-M1

                 Issue Date           November 16, 2018




TA Technology (Shanghai) Co., Ltd. tested the above equipment in accordance with the requirements in FCC
47 CFR Part 1 1.1310. The test results show that the equipment tested is capable of demonstrating compliance
with the requirements as documented in this report.




                  Performed by: Jiangpeng Lan                    Approved by: Kai Xu




               TA Technology (Shanghai) Co., Ltd.
                  No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China
                                        TEL: +86-021-50791141/2/3
                                     FAX: +86-021-50791141/2/3-8000


           MPE Test Report                                                                                      Report No: R1809A0442-M1




                                                     Table of Contents
1  Test Laboratory............................................................................................................................... 3
 1.1    Notes of the Test Report ......................................................................................................... 3
 1.2    Test facility .............................................................................................................................. 3
 1.3    Testing Location ...................................................................................................................... 4
 1.4    Laboratory Environment .......................................................................................................... 4
2 Description of Equipment under Test .............................................................................................. 5
3 Maximum conducted output power (measured) and antenna Gain ................................................ 6




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 2 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          MPE Test Report                                                                        Report No: R1809A0442-M1




1 Test Laboratory

1.1 Notes of the Test Report

This report shall not be reproduced in full or partial, without the written approval of TA technology

(shanghai) co., Ltd.The results documented in this report apply only to the tested sample, under the

conditions and modes of operation as described herein .Measurement Uncertainties were not taken

into account and are published for informational purposes only. This report is written to support

regulatory compliance of the applicable standards stated above.


1.2 Test facility

CNAS (accreditation number:L2264)
TA Technology (Shanghai) Co., Ltd. has obtained the accreditation of China National Accreditation
Service for Conformity Assessment (CNAS).
FCC (Designation number: CN1179, Test Firm Registration Number: 446626)
TA Technology (Shanghai) Co., Ltd. has been listed on the US Federal Communications Commission
list of test facilities recognized to perform electromagnetic emissions measurements.
IC (recognition number is 8510A)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Canada to perform electromagnetic
emission measurement.
VCCI (recognition number is C-4595, T-2154, R-4113, G-10766)
TA Technology (Shanghai) Co., Ltd. has been listed by industry Japan to perform electromagnetic
emission measurement.
A2LA (Certificate Number: 3857.01)
TA Technology (Shanghai) Co., Ltd. has been listed by American Association for Laboratory
Accreditation to perform electromagnetic emission measurement.




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 3 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           MPE Test Report                                                                       Report No: R1809A0442-M1


1.3 Testing Location


   Company:             TA Technology (Shanghai) Co., Ltd.

   Address:             No.145, Jintang Rd, Tangzhen Industry Park, Pudong Shanghai, China

   City:                Shanghai

   Post code:           201201
   Country:             P. R. China

   Contact:             Xu Kai

   Telephone:           +86-021-50791141/2/3

   Fax:                 +86-021-50791141/2/3-8000
   Website:             http://www.ta-shanghai.com

   E-mail:              xukai@ta-shanghai.com




1.4 Laboratory Environment

   Temperature                                             Min. = 18C, Max. = 25 C

   Relative humidity                                       Min. = 30%, Max. = 70%

   Ground system resistance                                < 0.5 
   Ambient noise is checked and found very low and in compliance with requirement of standards.
   Reflection of surrounding objects is minimized and in compliance with requirement of standards.




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 4 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          MPE Test Report                                                                        Report No: R1809A0442-M1



2 Description of Equipment under Test

 Client Information
   Applicant                           Quectel Wireless Solutions Co., Ltd
                                       7th Floor, Hongye Building, No.1801 Hongmei Road, Xuhui District,
   Applicant address
                                       Shanghai 200233, China
   Manufacturer                        Quectel Wireless Solutions Co., Ltd
                                       7th Floor, Hongye Building, No.1801 Hongmei Road, Xuhui District,
   Manufacturer address
                                       Shanghai 200233, China


General Technologies
   Model                               BC66
   IMEI                                867997030054273
   Hardware Version                    R1.0
   Software Version                    BC66NBR01A06
   Date of Testing:                    October 29, 2018 ~ November 12, 2018




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 5 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


          MPE Test Report                                                                        Report No: R1809A0442-M1



3 Maximum conducted output power (measured) and antenna Gain

The numeric gain (G) of the antenna with a gain specified in dB is determined by


                                                                     Maximum Conducted Output Power (dBm)
                            Band
                                                                           (dBm)                            (mW)
                     NB-IOT Band 2                                         25.00                           316.23
                     NB-IOT Band 4                                         25.00                           316.23
                     NB-IOT Band 5                                         25.00                           316.23
                    NB-IOT Band 12                                         25.00                           316.23
                    NB-IOT Band 13                                         25.00                           316.23
                    NB-IOT Band 17                                         25.00                           316.23
                    NB-IOT Band 25                                         25.00                           316.23
                    NB-IOT Band 66                                         25.00                           316.23




TA Technology (Shanghai) Co., Ltd.                                                                                  Page 6 of 9
This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


               MPE Test Report                                                                        Report No: R1809A0442-M1



     4 Test Result

         According to section 1.1310 of FCC 47 CFR Part 1, limits for maximum permissible exposure

         (MPE) are as following




Note1. Occupational/controlled limits apply in situations in which persons are exposed as a consequence of

       their employment provided those persons are fully aware of the potential for exposure and can

       exercise control over their exposure. Limits for occupational/controlled exposure also apply in

       situations when an individual is transient through a location where occupational / controlled limits apply

       provided he or she is made aware of the potential for exposure.

Note2: General population/uncontrolled exposures apply in situations in which the general public may be

       exposed, or in which persons that are exposed as a consequence of their employment may not be fully

       aware of the potential for exposure or can not exercise control over their exposure.




     TA Technology (Shanghai) Co., Ltd.                                                                                  Page 7 of 9
     This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


           MPE Test Report                                                                        Report No: R1809A0442-M1
    The maximum permissible exposure for 300~1500 MHz is f/1500, for 1500~100,000MHz is 1.0.So



                       Band                                        The maximum permissible exposure

                 NB-IOT Band 2                                                      1.00mW/cm2
                 NB-IOT Band 4                                                      1.00mW/cm2
                 NB-IOT Band 5                                                      0.55mW/cm2
                NB-IOT Band 12                                                      0.47mW/cm2
                NB-IOT Band 13                                                      0.52mW/cm2
                NB-IOT Band 17                                                      0.47mW/cm2
                NB-IOT Band 25                                                      1.00mW/cm2
                NB-IOT Band 66                                                      1.00mW/cm2



                           Maximum                                       Power density Limit
                                                EIRP
                           Conducted                       Margin1                                      Margin2        Final
        Band                                    limit
                            Output                          (dB)                                         (dB)         Margin
                                               (dBm)                     (mW/cm2)          (dBm)
                          Power (dBm)                                                                                  (dB)

  NB-IOT Band 2                25.00           33.00          8.00           1.00           37.01         12.01         8.00
  NB-IOT Band 4                25.00           30.00          5.00           1.00           37.01         12.01         5.00
  NB-IOT Band 5                25.00            40.60        15.60           0.55           34.42          9.42         9.42
 NB-IOT Band 12                25.00           36.92         11.92           0.47           33.73          8.73         8.73
 NB-IOT Band 13                25.00            36.92        11.92           0.52           34.17          9.17         9.17
 NB-IOT Band 17                25.00            34.77         9.77           0.47           33.73          8.73         8.73
 NB-IOT Band 25                25.00            33.00         8.00           1.00           37.01         12.01         8.00
 NB-IOT Band 66                25.00            30.00         5.00           1.00           37.01         12.01         5.00
 Note: 1. The Maximum allowed antenna gain per Band should be less than or equal to the Final
 Margin.
 2. The Final Margin is determined and selected to the worst-case of Margin1 and Margin2.
 3. Margin1=EIRP Limit(dBm)-Maximum Conducted Power (dBm). EIRP limit reference standard
 part22, part24 and part27 for each band, EIRP = ERP + 2.15 (dB).
 4. Margin2=Power density Limit(dBm)-Maximum Conducted Power (dBm). Power density
 Limit(dBm): The max. obtained by MPE with 20cm.



 IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, the

antenna(s) used for this transmitter must be installed to provide a separation distance of at least 20

cm from all persons and must not be co-located or operating in conjunction with any other antenna

 TA Technology (Shanghai) Co., Ltd.                                                                                  Page 8 of 9
 This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.


            MPE Test Report                                                                        Report No: R1809A0442-M1

 or transmitter. No change to the antenna or the device is permitted. Any change to the antenna or

 the device could result in the device exceeding the RF exposure requirements and void user’s

 authority to operate the device.



RF Exposure Calculations:
 The following information provides the minimum separation distance for the highest gain antenna

 provided. This calculation is based on the conducted power, considering maximum power and antenna

 gain. The formula shown in KDB 447498 D01 is used in the calculation.

Equation from KDB 447498 D01 General RF Exposure Guidance v06 (10/23/2015) is:
                                                                        2
                                                        S= PG / 4∏R
                                                                              2
 Where:     S = power density (in appropriate units, e.g. mW/cm )

           P = Time-average maximum tune up procedure (in appropriate units, e.g., mW)

           G = the numeric gain of the antenna

           R = distance to the center of radiation of the antenna (20 cm = limit for MPE)



                                                                  Test Result         Limit Value
                       Band                     PG (mW)                       2                   2      Conclusion
                                                                   (mW/cm )            (mW/cm )
                NB-IOT Band 2                    1995.26               0.40                1.00               Pass
                NB-IOT Band 4                    1000.00               0.20                1.00               Pass
                NB-IOT Band 5                    2766.94               0.55                0.55               Pass
                NB-IOT Band 12                   2360.48               0.47                0.47               Pass
                NB-IOT Band 13                   2612.16               0.52                0.52               Pass
                NB-IOT Band 17                   2360.48               0.47                0.47               Pass
                NB-IOT Band 25                   1995.26               0.40                1.00               Pass
                NB-IOT Band 66                   1000.00               0.20                1.00               Pass
         Note: R = 20cm
              ∏= 3.1416


 Note: For transmitters, minimum separation distance is 20cm, even if calculations indicate MPE
       distance is less.




  TA Technology (Shanghai) Co., Ltd.                                                                                  Page 9 of 9
  This report shall not be reproduced except in full, without the written approval of TA Technology (Shanghai) Co., Ltd.



Document Created: 2019-03-27 15:31:02
Document Modified: 2019-03-27 15:31:02

© 2024 FCC.report