SAR Test Report-2

FCC ID: XMF-MID7015

RF Exposure Info

Download: PDF
FCCID_4331214

ntertek
Total Quality. Assured.
                                                                                                |

                              !\" in Colleboration with

                              ue                       zumouino:mn
                            Add: No.51 Xueyuan Road, Haidian District, Beijing, 100191, China
                            Tel: +86—10—62304633—2512     Fax: +86—10—62304633—2504
                            E—mail: ettl@chinattl.com      Hitp://www.chinattl.en

                   Glossary:
                   DAE                             data acquisition electronics
                   Connector angle                  information used in DASY system to align probe sensor X
                                                   to the robot coordinate system.


                   Methods Applied and Interpretation of Parameters:
                   e DC Voltage Measurement: Calibration Factor assessed for use in DASY
                      system by comparison with a calibrated instrument traceable to national
                      standards. The figure given corresponds to the full scale range of the
                     voltmeter in the respective range.

                  «_      Connector angle: The angle of the connector is assessed measuring the
                          angle mechanically by a tool inserted. Uncertainty is not required.

                  &       The report provide only calibration results for DAE, it does not contain other
                          performance test results.




                  Certificate No: Z18—60297                                Page 2 of 3


ntertek
Total Quality. Assured.




                               71. $..L..2.4...9.........
                                                        in Collaboration with
                                                        $
                                                        CALIBRATION LABORATORY
                              Add: No.51 Xueyuan Road, Haidian Distrct, Beijing, 100191, China
                              Tel: +86—10—62304633—25 12     Fax: +86—10—62304633—2504
                              E—mail: cttl@chinattl.com      Hitp://www.chinattlen

                   DC Voltage Measurement
                          AID — Converter Resolution nominal
                              High Range:       1LSB =       6AuV,   full range =
                              Low Range:        1LSB =        64nV , full range =
                          DASY measurement parameters: Auto Zero Time: 3 sec; Measuring time: 3 see


                           Calibration Factors                    X                              Y
                           High Range                  404.030 + 0.15% (k=2) 404.628 + 0.15% (k=2)          404.476 £0.15% (k=2)

                           Low Range                   3.95429 + 0.7% (k=2)         3.99515 4+ 0.7% (k=2)   3.98817+0.7% (k=2)



                  Connector Angle

                          Connector Angle to be used in DASY system                                              346.5°+1°




                 Certificate No: Z18—60297                                  Page3 of 3


ntertek                                                                                                          ,
Total Quality. Assured.




            Callbl.'atlon Laboratory of                                        ¢\“\‘t\l./'j7"/¢                           S     Schweizerischer Kalibrierdienst
            Schmid & Partner                                                  i\'agwfi                                           Service suisse d‘étalonnage
              Engineering AG                                                  T ns                                        C     Servizio svizzero di taratura
            Zeughausstrasse 43, 8004 Zurich, Switzerland                       {'4,4”///:\\\\\‘\‘\\3                      S     Swiss Calibration Service



            Accredited by the Swiss Accreditation Service (SAS)                                                           Accreditation No.: SCS 0108
            The Swiss Accreditation Service is one of the signatories to the EA
            Multilateral Agreement for the recognition of calibration certificates

            Client        Auden                                                                                 Certificate No: D2450V2—735_Dec17

            CALIBRATION CERTIFICATE
             Object                                D2450V2 — SN:735


             Calibration procedure(s)              QA CAL—05.v9
                                                   Calibration procedure for dipole validation kits above 700 MHz



             Calibration date:                     December 15, 2017


             This calibration certificate documents the traceability to national standards, which realize the physical units of measurements (S1).
             The measurements and the uncertainties with confidence probability are given on the following pages and are part of the certificate.

              All calibrations have been conducted in the closed laboratory facility: environment temperature (22 + 3)°C and humidity < 70%.


              Calibration Equipment used (M&TE critical for calibration)


              Primary Standards                      ID #                      Cal Date (Certificate No.)                            Scheduled Calibration
              Power meter NRP                        SN: 104778                04—Apr—17 (No. 217—02521/02522)                       Apr—18
              Power sensor NRP—Z91                   SN: 103244                04—Apr—17 (No. 217—02521)                             Apr—18
              Power sensor NRP—Z91                   SN: 103245                04—Apr—17 (No. 217—02522)                             Apr—18
              Reference 20 dB Attenuator             SN: 5058 (20k)            O7—Apr—17 (No. 217—02528)                             Apr—18
              Type—N mismatch combination            SN: 5047.2 / 06327        O7—Apr—17 (No. 217—02529)                             Apr—18
              Reference Probe EX3DV4                 SN: 7349                  31—May—17 (No. EX3—7349_May17)                        May—18
              DAE4                                   SN: 601                   26—Oct—17 (No. DAE4—601_Oct17)                        Oct—18


              Secondary Standards                    ID #                      Check Date (in house)                                 Scheduled Check
              Power meter EPM—442A                   SN: GB37480704            07—Oct—15 (in house check Oct—16)                     In house check: Oct—18
              Power sensor HP 8481A                  SN: US37202783            07—Oct—15 (in house check Oct—16)                     In house check: Oct—18
              Power sensor HP 8481A                  SN: MY41092317            07—Oct—15 (in house check Oct—16)                     In house check: Oct—18
              RF generator R&S SMT—06                SN: 100972                15—Jun—15 (in house check Oct—16)                     In house check: Oct—18
              Network Analyzer HP 8753E              SN: US37390585            18—Oct—01 (in house check Oct—17)                     In house check: Oct—18




                                                                                                                                   P
                                                     Name                                         Function
              Calibrated by:                         Leif Klysner                                 Laboratory Technician



              Approved by:                           KatJa Pokovic                                Technical Manager
                                                                                                                                     ktr
                                                                                                                                     issued: December 18, 2017
              This calibration certificate shall not be reproduced except in full without written approval of the laboratory.


             Certificate No: D2450V2—735_Dec17                                       Page 1 of 8




  es


ntertek
Total Quality. Assured.




                 ;         5                                              wtm
            Cahbfatlon Laboratory of                                    i\‘\\fi_j///”’;    S   Schweizerischer Kalibrierdienst
            Schm{d & I_’anner                                          ;BE/mfi             c   Service suisse d‘étalonnage
              Engmeenng AG                                             Ne ol                  Servizio svizzero di taratura
            Zeughausstrasse 43, 8004 Zurich, Switzerland                *4///-—\\\\\\*‘   S   Swiss Calibration Service
                                                                           ulsdtuls®

            Accredited by the Swiss Accreditation Service (SAS)                           Accreditation No.: SCS 0108
            The Swiss Accreditation Service is one of the signatories to the EA
            Multilateral Agreementfor the recognition of calibration certificates
            Glossary:
            TSL                          tissue simulating liquid
            ConvF                        sensitivity in TSL / NORM x,y,z
            N/A                          not applicable or not measured

            Calibration is Performed According to the Following Standards:
                 a)   IEEE Std 1528—2013, "EEE Recommended Practice for Determining the Peak Spatial—
                      Averaged Specific Absorption Rate (SAR) in the Human Head from Wireless
                      Communications Devices: Measurement Techniques", June 2013
                 b)   IEC 62209—1, "Measurement procedure for the assessment of Specific Absorption Rate
                      (SAR) from hand—held and body—mounted devices used next to the ear (frequency range of
                      300 MHz to 6 GHz)", July 2016
                 c)   IEC 62209—2, "Procedure to determine the Specific Absorption Rate (SAR) for wireless
                      communication devices used in close proximity to the human body (frequency range of 30
                      MHz to 6 GHz)", March 2010
                 d)   KDB 865664, "SAR Measurement Requirements for 100 MHz to 6 GHz"

            Additional Documentation:
               e) DASY4/5 System Handbook
             Methods Applied and Interpretation of Parameters:
                  Measurement Conditions: Further details are available from the Validation Report at the end
                  of the certificate. All figures stated in the certificate are valid at the frequency indicated.
                  Antenna Parameters with TSL: The dipole is mounted with the spacer to position its feed
                  point exactly below the center marking of the flat phantom section, with the arms oriented
                  parallel to the body axis.
                  Feed Point Impedance and Return Loss: These parameters are measured with the dipole
                  positioned under the liquid filled phantom. The impedance stated is transformed from the
                  measurement at the SMA connector to the feed point. The Return Loss ensures low
                  reflected power. No uncertainty required.
                  Electrical Delay: One—way delay between the SMA connector and the antenna feed point.
                  No uncertainty required.
                  SAR measured: SAR measured at the stated antenna input power.
                  SAR normalized: SAR as measured, normalized to an input power of 1 W at the antenna
                          connector.
                          SAR for nominal TSL parameters: The measured TSL parameters are used to calculate the
                          nominal SAR result.
               The reported uncertainty of measurement is stated as the standard uncertainty of measurement
               multiplied by the coverage factor k=2, which for a normal distribution corresponds to a coverage
               probability of approximately 95%.




             Certificate No: D2450V2—735_Dec17                              Page 2 of 8


ntertek
Total Quality. Assured.




            Measurement Conditions
                 DASY system configuration, as far as not iven onpage 1.
                    DASY Version                                              DASY5                              V52.10.0
                    Extrapolation                                  Advanced Extrapolation
                    Phantom                                         Modular Flat Phantom

                    Distance Dipole Center — TSL                              10 mm                             with Spacer

                   Zoom Scan Resolution                               dx, dy, dz =5 mm
                    Frequency                                         2450 MHz +1 MHz



             Head TSL parameters
                 The following parameters and calculations were applied.
                                                                              Temperature       Permittivity          Conductivity
                    Nominal Head TSL parameters                                  22.0 °C           39.2                1.80 mho/m
                    Measured Head TSL parameters                              (22.0 + 0.2) °C   37.7 6 %           1.87 mho/m + 6 %

                    Head TSL temperature change during test                      <0.5 °C

             SAR result with Head TSL

                    SAR averaged over 1 cm* (1 g) of Head TSL                  Condition
                    SAR measured                                       250 mW input power                      13.2 Wikg
                    SAR for nominal Head TSL parameters                     normalized to 1W         51.4 Wikg + 17.0 % (k=2)

                    SAR averaged over 10 cm* (10 g) of Head TSL                 condition
                    SAR measured                                        250 mW input power                  6.07 Wikg
                    SAR for nominal Head TSL parameters                     normalized to 1W         23.9 Wikg + 16.5 %(k=2)


             Body TSL parameters
                  The following parameters and calculations were applied.
                                                                              Temperature       Permittivity          Conductivity
                    Nominal Body TSL parameters                                  22.0 °C            52.7               1.95 mho/m
                    Measured Body TSL parameters                              (22.0 + 0.2) °C    51.5 +6 %         2.04 mho/m + 6 %
                    Body TSL temperature change during test                      <0.5 °C


             SAR result with Body TSL

                    SAR averaged over 1 cm* (1 g) of Body TSL                   Condition
                    SAR measured                                        250 mW input power                     13.0 Wi/kg

                    SAR for nominal Body TSL parameters                     normalized to 1W         50.6 W/kg + 17.0 % (k=2)

                    SAR averaged over 10 cm* (10 g) of Body TSL                 condition
                    SAR measured                                        250 mW input power                  6.06 W/kg
                    SAR for nominal Body TSL parameters                     normalized to 1W         23.9 Wikg + 16.5 % (k=2)



             Certificate No: D2450V2—735_Dec17                       Page 3 of 8




  brxr   avw l r wexe se w s   ce


ntertek
Total Quality. Assured.




            Appendix (Additional assessments outside the scope of SCS 0108)

            Antenna Parameters with Head TSL

                   Impedance, transformed to feed point                                          54.9 Q + 4.9 jQ

                   Return Loss                                                                      —23.6 dB



            Antenna Parameters with Body TSL

                   Impedance, transformed to feed point                                          49.7 Q + 7.1 jQ

                   Return Loss                                                                      —22.9 dB




            General Antenna Parameters and Design

                    Electrical Delay (one direction)                                                 1.154 ns


            After long term use with 100W radiated power, only a slight warming of the dipole near the feedpoint can be measured.

            The dipole is made of standard semirigid coaxial cable. The center conductor of the feeding line is directly connected to the
            second arm of the dipole. The antenna is therefore short—circuited for DC—signals. On some of the dipoles, small end caps
            are added to the dipole arms in order to improve matching when loaded according to the position as explained in the
            "Measurement Conditions" paragraph. The SAR data are not affected by this change. The overall dipole length is still
            according to the Standard.
            No excessive force must be applied to the dipole arms, because they might bend or the soldered connections near the
            feedpoint may be damaged.



             Additional EUT Data

                    Manufactured by                                                                  SPEAG
                    Manufactured on                                                               May 07, 2003




             Certificate No: D2450V2—735_Dec17                        Page 4 of 8




  n      w.!


ntertek
Total Quality. Assured.




           DASY5 Validation Report for Head TSL

                                                                                                Date: 15.12.2017

           Test Laboratory: SPEAG, Zurich, Switzerland

           DUT: Dipole 2450 MHz; Type: D2450V2; Serial: D2450V2 — SN: 735

           Communication System: UID 0 — CW; Frequency: 2450 MHz
           Medium parameters used: f = 2450 MHz; 0 = 1.87 S/m:; & = 37.7; p = 1000 kg/m‘
           Phantom section: Flat Section
           Measurement Standard: DASYS5 (IEEE/IEC/ANSI C63.19—2011)

           DASY52 Configuration:

                e    Probe: EX3DV4 — SN7349; ConvF(8.12, 8.12, 8.12); Calibrated: 31.05.2017;

                *    Sensor—Surface: 1.4mm (Mechanical Surface Detection)

                e    Electronics: DAE4 Sn601; Calibrated: 26.10.2017

                *    Phantom: Flat Phantom 5.0 (front); Type: QD 000 P50 AA; Serial: 1001

                *    DASY52 52.10.0(1446); SEMCAD X 14.6.10(7417)


            Dipole Calibration for Head Tissue/Pin=250 mW, d=10mm/Zoom Scan (7x7x7)/Cube 0:
            Measurement grid: dx=5mm, dy=5mm, dz=5mm
            Reference Value = 113.0 V/m; Power Drift = —0.08 dB
            Peak SAR (extrapolated) = 27.3 W/kg
            SAR(1 g) = 13.2 W/kg; SAR(10 g) = 6.07 W/kg
            Maximum value of SAR (measured) = 21.4 W/kg


                     dB
                      0

                      ~4.00

                      —8.00

                      —12.00

                      —16.00

                      —20.00
                               0 dB = 21.4 W/kg = 13.30 dBW/kg




            Certificate No: D2450V2—735_Dec17                Page 5 of 8


ntertek
Total Quality. Assured.




            Impedance Measurement Plot for Head TSL




                                                                                 15 Dec 2017 13:46:33
                          CHI sii    1 U FS           1: 54.977 a    4.9355 0 320.62 pH      2 450.000 000 MHz
                                                                    n=p——<




                          Del

                          Ca




                          fivg
                          16


                          H1d

                          CH2




                          Ca




                          Av
                          16°

                          H1d

                                    START 2 250.000 000 MHz                            STOP 2 650.000 000 MHz




             Certificate No: D2450V2—735_Dec17                        Page 6 of 8


ntertek
Total Quality. Assured.




           DASY5 Validation Report for Body TSL

                                                                                             Date: 15.12.2017

           Test Laboratory: SPEAG, Zurich, Switzerland

           DUT: Dipole 2450 MHz; Type: D2450V2; Serial: D2450V2 — SN: 735

           Communication System: UID 0 — CW; Frequency: 2450 MHz
           Medium parameters used: f = 2450 MHz; o = 2.04 S/m; & = 51.5; p = 1000 kg/m‘
           Phantom section: Flat Section
           Measurement Standard: DASY5 (IEEE/IEC/ANSI C63.19—2011)

           DASY52 Configuration:

                     Probe: EX3DV4 — SN7349; ConvF(8.1, 8.1, 8.1); Calibrated: 31.05.2017;

                     Sensor—Surface: 1.4mm (Mechanical Surface Detection)

                     Electronics: DAE4 $n601; Calibrated: 26.10.2017

                     Phantom: Flat Phantom 5.0 (back); Type: QD 000 P50 AA; Serial: 1002

                     DASY52 52.10.0(1446); SEMCAD X 14.6.10(7417)


            Dipole Calibration for Body Tissue/Pin=250 mWd=10mm/Zoom Scan (7x7x7)/Cube 0:
            Measurement grid: dx=5mm, dy=5mm, dz=5mm
            Reference Value = 105.9 V/m; Power Drift = —0.09 dB
            Peak SAR (extrapolated) = 26.0 W/kg
            SAR(1 g) = 13 W/kg; SAR(10 g) = 6.06 W/kg
            Maximum value of SAR (measured) = 20.4 W/kg


                     dB
                      0

                      —4.00




                      —12.00

                      —16.00

                      —20.00
                               0 dB = 20.4 W/kg = 13.10 dBW/kg




            Certificate No: D2450V2—735_Dec17                Page 7 of 8


ntertek
Total Quality. Assured.




              Impedance Measurement Plot for Body TSL




                                                                                   15 Dec 2017 13:49:06
                          CHI sii     1 U FS          1: 49.717 a   if7.1328 0> 463.36 P pH    2 450.000 000 MHz
                                                                              *z




                          fAvg
                          16


                          H1d


                          CH2




                          Ca




                          Av
                          16 8



                          H1d

                                    START 2 250.000 000 MHz                             STOP 2 650.000 000 MHz




               Certificate No: D2450V2—735_Dec17                      Page 8 of 8


                                               Intertek Report No.: 190604008SZN-001

                     ANNEX F : EUT PHOTOS

                       External Photo of EUT




TRF No.: FCC SAR_b                                            Page 65 of 70


                     Intertek Report No.: 190604008SZN-001




TRF No.: FCC SAR_b                  Page 66 of 70


                                             Intertek Report No.: 190604008SZN-001

                     Internal Photo of EUT




TRF No.: FCC SAR_b                                          Page 67 of 70


                     Intertek Report No.: 190604008SZN-001




TRF No.: FCC SAR_b                  Page 68 of 70


                     Intertek Report No.: 190604008SZN-001




TRF No.: FCC SAR_b                  Page 69 of 70


                                                 Intertek Report No.: 190604008SZN-001




                     **********End of Report**********




TRF No.: FCC SAR_b                                              Page 70 of 70