Test Report

FCC ID: XLY-DP700

Test Report

Download: PDF
FCCID_4170305

                                  Page 1 of 27    Report No.: S19010703501001




    FCC RADIO TEST REPORT
       FCC ID: XLY-DP700
                          SMART CARD READER/WRITER FOR
               Product:
                          RFID SYSTEM
           Trade Mark: ZEPHYR LOCK
          Model Name: DP700S
         Family Model: N/A
            Report No.: S19010703501001




                         Prepared for

                    Zephyrlock,LLC
    14 Finance Drive Danbury, CT United States 06810




                          Prepared by
            Shenzhen NTEK Testing Technology Co., Ltd.
1/F, Building E, Fenda Science Park, Sanwei Community,Xixiang Street
               Bao’an District, Shenzhen 518126 P.R. China
           Tel.: +86-755-6115 6588 Fax.: +86-755-6115 6599
                      Website:http://www.ntek.org.cn


                                                                             Page 2 of 27        Report No.: S19010703501001



                                             TEST RESULT CERTIFICATION

    Applicant’s name ................. : Zephyrlock,LLC
    Address ................................. : 14 Finance Drive Danbury, CT United States 06810
    Manufacturer's Name .......... : Dongguan TonXon Intelligent Technology Co.,Ltd.
    Address ................................. : Linwuzhou, Shayao Management District, Shijie Town, Dongguan
                                                City, Guangdong Province, China
    Product description
    Product name ........................... : SMART CARD READER/WRITER FOR RFID SYSTEM
    Model and/or type reference : DP700S
    Family Model:                                    N/A
    Standards ............................. : FCC Part15.225

    Test procedure ...............................ANSI
                                                  :    C63.10-2013
    This device described above has been tested by NTEK, and the test results show that the
    equipment under test (EUT) is in compliance with the FCC requirements. And it is applicable only
    to the tested sample identified in the report.
    This report shall not be reproduced except in full, without the written approval of NTEK, this
    document may be altered or revised by NTEK, personnel only, and shall be noted in the revision of
    the document.
    Date of Test ............................................ :
    Date (s) of performance of tests ............. :                08 Jan. 2019 ~ 26 Jan. 2019
    Date of Issue ........................................... :     26 Jan. 2019
    Test Result ............................................... :   Pass




                              Testing Engineer                  :

                                                                                   (Allen Liu)


                              Technical Manager                 :

                                                                               (Jason Chen)



                              Authorized Signatory :

                                                                               (Sam Chen)




`


                                                  Page 3 of 27   Report No.: S19010703501001




                              Table of Contents                                 Page


    1 . SUMMARY OF TEST RESULTS                                                        4
      1.1 TEST FACILITY                                                                5
      1.2 MEASUREMENT UNCERTAINTY                                                      5
    2 . GENERAL INFORMATION                                                            6
      2.1 GENERAL DESCRIPTION OF EUT                                                   6
      2.2 DESCRIPTION OF TEST MODES                                                    7
      2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED                      8
      2.4 DESCRIPTION OF SUPPORT UNITS(CONDUCTED MODE)                                 9
      2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS                                        10
    3 . ANTENNA REQUIREMENT                                                         11
      3.1 STANDARD REQUIREMENT                                                      11
      3.2 EUT ANTENNA                                                               11
    4 . EMC EMISSION TEST                                                           12
      4.1     CONDUCTED EMISSION MEASUREMENT                                        12
            4.1.1 POWER LINE CONDUCTED EMISSION LIMITS                              12
            4.1.2 TEST CONFIGURATION                                                12
            4.1.3 TEST PROCEDURE                                                    12
            4.1.4 TEST RESULT                                                       13
      4.2 RADIATED EMISSION MEASUREMENT                                             17
         4.2.1 RADIATED EMISSION LIMITS                                             17
         4.2.2 TEST PROCEDURE                                                       18
         4.2.3 DEVIATION FROM TEST STANDARD                                         18
         4.2.4 TEST SETUP                                                           19
         4.2.5 TEST RESULTS (BELOW 30MHZ)                                           20
         4.2.6 TEST RESULTS (BETWEEN 30 – 1000 MHZ)                                 22
    5 . BANDWIDTH TEST                                                              24
            5.1 TEST PROCEDURE                                                      24
            5.2 DEVIATION FROM STANDARD                                             24
            5.3 TEST SETUP                                                          24
            5.4 TEST RESULTS                                                        25
    6. FREQUENCY TOLERANCE                                                          26




`


                                                         Page 4 of 27    Report No.: S19010703501001



    1. SUMMARY OF TEST RESULTS

    Test procedures according to the technical standards:
                                    FCC Part15, Subpart C (15.225)
        Standard
                                       Test Item                        Judgment         Remark
         Section
         15.207                  Conducted Emission                      Pass
        15.205(a)
         15.209              Radiated Spurious Emission                  Pass
         15.225
         15.225                     20dB Bandwidth                       Pass

         15.225                  Frequency Tolerance                     Pass

         15.203                  Antenna Requirement                     Pass


    NOTE:
    (1) ” N/A” denotes test is not applicable in this Test Report.




`


                                                        Page 5 of 27      Report No.: S19010703501001


    1.1 TEST FACILITY

    All measurement facilities used to collect the measurement data are located at
    1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang Street, Bao’an District, Shenzhen
    518126 P.R. China.
    The sites are constructed in conformance with the requirements of ANSI C63.7, ANSI C63.10 and
    CISPR Publication 22.
    Site Description
    CNAS-Lab.                    : The Laboratory has been assessed and proved to be in
                                     compliance with CNAS-CL01:2006 (identical to ISO/IEC
                                     17025:2005)
                                     The Certificate Registration Number is L5516.


    IC-Registration                  The Certificate Registration Number is 9270A-1.


    FCC- Accredited                  Test Firm Registration Number: 463705.
                                     Designation Number: CN1184
    A2LA-Lab.                        The Certificate Registration Number is 4298.01
                                     This laboratory is accredited in accordance with the recognized
                                     International Standard ISO/IEC 17025:2005 General
                                     requirements for the competence of testing and calibration
                                     laboratories.
                                     This accreditation demonstrates technical competence for a
                                     defined scope and the operation of a laboratory quality
                                     management system
                                     (refer to joint ISO-ILAC-IAF Communiqué dated 8 January 2009).
    Name of Firm                 : Shenzhen NTEK Testing Technology Co., Ltd.
    Site Location                : 1/F, Building E, Fenda Science Park, Sanwei Community, Xixiang
                                     Street, Bao’an District, Shenzhen 518126 P.R. China.


    1.2 MEASUREMENT UNCERTAINTY
      The reported uncertainty of measurement y ± U,where expended uncertainty U is based on a
      standard uncertainty multiplied by a coverage factor of k=2,providing a level of confidence of
      approximately 95 %。

                    No.   Item                                   Uncertainty
                    1     Conducted Emission Test                ±1.38dB
                    2     RF power,conducted                     ±0.16dB
                    3     Spurious emissions,conducted           ±0.21dB
                    4     All emissions,radiated(<1G)            ±4.68dB
                    5     All emissions,radiated(>1G)            ±4.89dB
                    6     Temperature                            ±0.5°C
                    7     Humidity                               ±2%




`


                                                        Page 6 of 27         Report No.: S19010703501001



    2. GENERAL INFORMATION

    2.1 GENERAL DESCRIPTION OF EUT



              Equipment               SMART CARD READER/WRITER FOR RFID SYSTEM
              Trade Mark              ZEPHYR LOCK
              Model Name              DP700S
              Family Model            N/A
              Model Difference        N/A
                                      The EUT is a SMART CARD READER/WRITER FOR
                                      RFID SYSTEM

                                      Operation Frequency:    13.56MHz
              Product Description     Modulation Type:        ASK
                                      Number Of Channel       1CH.
                                      Antenna Designation:    Loop Antenna
                                      Antenna Gain(Peak)      0 dBi
              Adapter                 N/A
              Battery                 N/A
              Rating                  DC 5V from USB Port.
              HW Version              V2.1
              SW Version              V3.6




    Note:
        1. For a more detailed features description, please refer to the manufacturer’s specifications
           or the User's Manual.

        2.
             Table for Filed Antenna
              Ant
                     Brand       Model Name     Antenna Type     Connector Gain (dBi)         NOTE
               .
              1         N/A         N/A         Loop Antenna           N/A          0        Antenna




`


                                                     Page 7 of 27    Report No.: S19010703501001


    2.2 DESCRIPTION OF TEST MODES

      To investigate the maximum EMI emission characteristics generates from EUT, the test system
      was pre-scanning tested base on the consideration of following EUT operation mode or test
      configuration mode which possible have effect on EMI emission level. Each of these EUT
      operation mode(s) or test configuration mode(s) mentioned above was evaluated respectively.

          Pretest Mode                             Description
             Mode 1                               TX-13.56MHz


                                 For Conducted Emission

         Final Test Mode                           Description
             Mode 1                               TX-13.56MHz

                                  For Radiated Emission

         Final Test Mode                           Description
             Mode 1                               TX-13.56MHz




`


                                                            Page 8 of 27     Report No.: S19010703501001


    2.3 BLOCK DIGRAM SHOWING THE CONFIGURATION OF SYSTEM TESTED

    For AC Conducted Emission Mode

                                                                  AC PLUG
                         C-2                  C-1
                                 AE-2
          EUT                    Notebook
                                                        AE-1
                                                        Adapter
                                                        e




    For Radiated Test Cases

                                                                  AC PLUG
                         C-2                  C-1
                                 AE-2
          EUT                    Notebook
                                                        AE-1
                                                        Adapter
                                                        e




    For Conducted Test Cases



                                                                                          AC PLUG
                         C-3
      Measurement                            C-2                   C-1      AE-1
                                                      AE-2
        Instrument
                                 EUT                  Notebook              Adapter
                                                                            e




    Note:The temporary antenna connector is soldered on the PCB board in order to perform conducted tests and
    this temporary antenna connector is listed in the equipment list.




`


                                                                Page 9 of 27   Report No.: S19010703501001

    2.4 DESCRIPTION OF SUPPORT UNITS (CONDUCTED MODE)

    The EUT has been tested as an independent unit together with other necessary accessories or
    support units. The following support units or accessories were used to form a representative test
    configuration during the tests.

     Item     Equipment          Brand            Model/Type No.               Series No.          Note
    AE-1       Adapter           N/A                   N/A                        N/A
    AE-2       Notebook      Lenovo            Thinkpad Edge E430                 N/A




       Item      Shielded Type     Ferrite Core         Length                          Note
       C-1            NO                 YES             1.2m
       C-2            NO                 YES             1.0m
       C-3           YES                 NO              0.1m




     Note:
      (1)     The support equipment was authorized by Declaration of Confirmation.
      (2)     For detachable type I/O cable should be specified the length in cm in『Length』column.




`


                                                              Page 10 of 27      Report No.: S19010703501001

    2.5 EQUIPMENTS LIST FOR ALL TEST ITEMS
Radiation& Conducted Test equipment
                                                                                                   Calibrati
                Kind of                                                    Last       Calibrated
     Item                    Manufacturer    Type No.      Serial No.                                on
               Equipment                                                calibration     until
                                                                                                    period
               Spectrum
       1                        Aglient       E4407B     MY45108040 2018.05.19        2019.05.18    1 year
               Analyzer
               Spectrum
       2                        Agilent       N9020A     MY49100060 2018.10.08        2019.10.04    1 year
               Analyzer
               Spectrum
       3                         R&S          FSV40         101417      2018.10.08    2019.10.04    1 year
               Analyzer
       4     Test Receiver       R&S          ESPI7         101318      2018.05.19    2019.05.18    1 year
       5     Bilog Antenna     TESEQ        CBL6111D        31216       2018.04.08    2019.04.07    1 year
              50Ω Coaxial
       6                        Anritsu       MP59B      6200983705     2018.05.19    2020.05.18    3 year
                Switch
                                       EM-AH-1018
       7     Horn Antenna        EM               2011071402            2018.04.08    2019.04.07    1 year
                                           0
              Active Loop    SCHWARZBE FMZB 1519
       8                                              055               2018.11.03    2019.11.02    1 year
               Antenna          CK         B
       9       LF Cable          N/A           R-03           N/A       2018.06.05    2021.06.05    3 year
              PSG Analog
      10        Signal          Agilent       E8257D     MY51110112     2018.08.05    2019.08.04    1 year
               Generator
               Test Cable
      11                         N/A           R-01           N/A       2017.04.21    2020.04.20    3 year
             (9KHz-30MHz)
              Test Cable
      12                         N/A           R-02           N/A       2017.04.21    2020.04.20    3 year
            (30MHz-1GHz)
    Note:
            1.We will use the temporary antenna connector (soldered on the PCB board) When conducted test
               And this temporary antenna connector is listed within the instrument list
            2. Each piece of equipment is scheduled for calibration once a year except the Test Cable& Aux
            Equipment which is scheduled for calibration every 3 years.




`


                                                         Page 11 of 27     Report No.: S19010703501001



    3. ANTENNA REQUIREMENT


    3.1 STANDARD REQUIREMENT

       15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall
        be designed to ensure that no antenna other than that furnished by the responsible party
       shall be used with the device.

    3.2 EUT ANTENNA

    The EUT antenna is permanent attached antenna. It comply with the standard requirement.




`


                                                                 Page 12 of 27     Report No.: S19010703501001



    4. EMC EMISSION TEST

    4.1 CONDUCTED EMISSION MEASUREMENT

    4.1.1 POWER LINE CONDUCTED EMISSION Limits                           (Frequency Range 150KHz-30MHz)
                                                                    Conducted Emission Limit
               Frequency(MHz)
                                                         Quasi-peak                         Average
                    0.15-0.5                                66-56*                           56-46*
                     0.5-5.0                                  56                               46
                    5.0-30.0                                  60                               50
     Note: 1. *Decreases with the logarithm of the frequency
            2. The lower limit shall apply at the transition frequencies
            3. The limit decreases in line with the logarithm of the frequency in the range of 0.15 to 0.50MHz.

    4.1.2 TEST CONFIGURATION
                      Reference
                      Ground
                                       EUT        Auxiliary       Reference
                                                  Equipment       Ground
           EMI Receiver

                                                                  50Ω
                                                          80cm
                                80cm
        LISN                                                            LISN


4.1.3 TEST PROCEDURE
 According to the requirements in Section 13.1.4.1 of ANSI C63.10-2013 Conducted emissions the
 EUT measured in the frequency range between 0.15 MHz and 30 MHz using CISPR Quasi-Peak
 and average detector mode.
 1. The EUT was placed 0.4 meter from the conducting wall of the shielding room.
 2. The EUT was placed on a table which is 0.8m above ground plane.
 3. Connect EUT to the power mains through a line impedance stabilization network (LISN). All other
     support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of
     coupling impedance for the measuring instrument.
 4. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and
     forth in the center forming a bundle 30 to 40cm long.
 5. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
     cable may be terminated, if required, using the correct terminating impedance. The overall length
     shall not exceed 1 m.
 6. LISN at least 80 cm from nearest part of EUT chassis.
 7. The frequency range from 150KHz to 30MHz was searched.
 8. Set the test-receiver system to Peak Detect Function and specified bandwidth(IF
     bandwidth=9KHz) with Maximum Hold Mode
 9. For the actual test configuration, please refer to the related Item –EUT Test Photos.




`


                                                               Page 13 of 27       Report No.: S19010703501001


    4.1.4 TEST RESULT

                         SMART CARD
    EUT:                 READER/WRITER FOR RFID Model Name :           DP700S
                         SYSTEM
    Temperature:         26 ℃                       Relative Humidity: 54%
    Pressure:            1010hPa                    Phase :            L
    Test Voltage :       DC 5V from PC AC 120V/60Hz Test Mode:         Mode 1


         Frequency      Reading Level Correct Factor    Measure-ment      Limits         Margin
                                                                                                   Remark
           (MHz)            (dBμV)            (dB)          (dBμV)       (dBμV)           (dB)

           0.1539           43.26             9.75          53.01         65.78          -12.77      QP

           0.1539           14.47             9.75          24.22         55.78          -31.56     AVG

           0.4939           35.09             9.74          44.83         56.10          -11.27      QP

           0.4939           28.88             9.74          38.62         46.10           -7.48     AVG

           0.8860           23.11             9.74          32.85         56.00          -23.15      QP

           0.8860           15.15             9.74          24.89         46.00          -21.11     AVG

           3.0099           24.34             9.83          34.17         56.00          -21.83      QP

           3.0099           13.00             9.83          22.83         46.00          -23.17     AVG

           13.5618          36.34            10.07          46.41         60.00          -13.59      QP

           13.5618          33.06            10.07          43.13         50.00           -6.87     AVG

           27.1219          36.52            10.59          47.11         60.00          -12.89      QP

           27.1219          35.78            10.59          46.37         50.00           -3.63     AVG
       Remark:
       1. All readings are Quasi-Peak and Average values.
       2. Factor = Insertion Loss + Cable Loss.




`


                                                              Page 14 of 27       Report No.: S19010703501001



                        SMART CARD READER/WRITER
    EUT:                                                           Model Name :         DP700S
                        FOR RFID SYSTEM
    Temperature:        26 ℃                                       Relative Humidity: 54%
    Pressure:           1010hPa                                    Phase :            N
    Test Voltage :      DC 5V from PC AC 120V/60Hz                 Test Mode:         Mode 1


       Frequency      Reading Level Correct Factor    Measure-ment       Limits        Margin
                                                                                                  Remark
         (MHz)            (dBμV)            (dB)          (dBμV)        (dBμV)          (dB)

         0.1580           44.08             9.74          53.82          65.56         -11.74       QP

         0.1580           16.12             9.74          25.86          55.56         -29.70      AVG

         0.4859           36.04             9.75          45.79          56.24         -10.45       QP

         0.4859           31.65             9.75          41.40          46.24         -4.84       AVG

         1.0140           20.73             9.75          30.48          56.00         -25.52       QP

         1.0140           14.04             9.75          23.79          46.00         -22.21      AVG

         1.4819           21.46             9.77          31.23          56.00         -24.77       QP

         1.4819           11.61             9.77          21.38          46.00         -24.62      AVG

         13.5618          34.59            10.07          44.66          60.00         -15.34       QP

         13.5618          32.27            10.07          42.34          50.00         -7.66       AVG

         27.1219          36.46            10.56          47.02          60.00         -12.98       QP

         27.1219          35.56            10.56          46.12          50.00         -3.88       AVG
     Remark:
     1. All readings are Quasi-Peak and Average values.
     2. Factor = Insertion Loss + Cable Loss.




`


                                                            Page 15 of 27       Report No.: S19010703501001



                      SMART CARD READER/WRITER
    EUT:                                                          Model Name :       DP700S
                      FOR RFID SYSTEM
                                                                  Relative
    Temperature: 26 ℃                                                                54%
                                                                  Humidity:
    Pressure:      1010hPa                                        Phase :            L
    Test Voltage : DC 5V from PC AC 240V/60Hz                     Test Mode:         Mode 1


      Frequency      Reading Level Correct Factor    Measure-ment      Limits         Margin
                                                                                                Remark
        (MHz)            (dBμV)            (dB)          (dBμV)       (dBμV)           (dB)

        0.4860           35.83             9.74          45.57         56.24          -10.67      QP

        0.4860           34.13             9.74          43.87         46.24           -2.37     AVG

        0.5220           32.51             9.74          42.25         56.00          -13.75      QP

        0.5220           28.28             9.74          38.02         46.00           -7.98     AVG

        1.1539           27.21             9.74          36.95         56.00          -19.05      QP

        1.1539           15.37             9.74          25.11         46.00          -20.89     AVG

        3.3140           28.25             9.84          38.09         56.00          -17.91      QP

        3.3140           16.51             9.84          26.35         46.00          -19.65     AVG

        13.5620          34.55            10.07          44.62         60.00          -15.38      QP

        13.5620          32.91            10.07          42.98         50.00           -7.02     AVG

        27.1220          37.03            10.59          47.62         60.00          -12.38      QP

        27.1220          36.17            10.59          46.76         50.00           -3.24     AVG
    Remark:
    1. All readings are Quasi-Peak and Average values.
    2. Factor = Insertion Loss + Cable Loss.




`


                                                              Page 16 of 27       Report No.: S19010703501001



                       SMART CARD READER/WRITER
    EUT:                                                             Model Name :     DP700S
                       FOR RFID SYSTEM
                                                                     Relative
    Temperature: 26 ℃                                                                 54%
                                                                     Humidity:
    Pressure:          1010hPa                                       Phase :          N
    Test Voltage :     DC 5V from PC AC 240V/60Hz                    Test Mode:       Mode 1


       Frequency      Reading Level Correct Factor    Measure-ment       Limits        Margin
                                                                                                  Remark
         (MHz)            (dBμV)            (dB)          (dBμV)         (dBμV)         (dB)

         0.4900           36.04             9.75          45.79          56.17         -10.38       QP

         0.4900           27.27             9.75          37.02          46.17         -9.15       AVG

         0.5220           32.58             9.75          42.33          56.00         -13.67       QP

         0.5220           25.58             9.75          35.33          46.00         -10.67      AVG

         1.5260           27.12             9.78          36.90          56.00         -19.10       QP

         1.5260           16.91             9.78          26.69          46.00         -19.31      AVG

         3.3140           25.14             9.89          35.03          56.00         -20.97       QP

         3.3140           18.23             9.89          28.12          46.00         -17.88      AVG

         13.5619          34.04            10.07          44.11          60.00         -15.89       QP

         13.5619          32.31            10.07          42.38          50.00         -7.62       AVG

         27.1220          37.02            10.56          47.58          60.00         -12.42       QP

         27.1220          36.05            10.56          46.61          50.00         -3.39       AVG
     Remark:
     1. All readings are Quasi-Peak and Average values.
     2. Factor = Insertion Loss + Cable Loss.




`


                                                        Page 17 of 27    Report No.: S19010703501001


    4.2 RADIATED EMISSION MEASUREMENT

    4.2.1 Radiated Emission Limits     ( FCC 15.209 )
          Frequencies              Field Strength                   Measurement Distance
              (MHz)              (micorvolts/meter)                      (meters)

          0.009~0.490                     2400/F(KHz)                         300
          0.490~1.705                    24000/F(KHz)                          30
           1.705~30.0                           30                             30
              30~88                            100                              3
             88~216                            150                              3
            216~960                            200                              3
           Above 960                           500                              3
          Note:
             (1) The tighter limit applies at the band edges.
             (2) Emission level (dBuV/m)=20log Emission level (uV/m).


         LIMITS OF RADIATED EMISSION MEASUREMENT ( FCC 15.225)

    (a)The field strength of any emissions within the band 13.553-13.567 MHz shall not exceed
    15,848 microvolts/meter at 30 meters, equal to 104dBuV/m at 3 meters.
    (b) Within the bands 13.410-13.553 MHz and 13.567-13.710 MHz, the field strength of any
    emissions shall not exceed 334 microvolts/meter at 30 meters, equal to 74.5dBuV/m at 3 meters.
    (c) Within the bands 13.110-13.410 MHz and 13.710-14.010 MHz the field strength of any
    emissions shall not exceed 106 microvolts/meter at 30 meters, equal to 60.5dBuV/m at 3 meters..
    (d) The field strength of any emissions appearing outside of the 13.110-14.010 MHz band shall not
    exceed the general radiated emission limits in § 15.209.




`


                                                           Page 18 of 27    Report No.: S19010703501001



     Spectrum Parameter                          Setting
     Attenuation                                 Auto
     Start Frequency                             1000 MHz
     Stop Frequency                              10th carrier harmonic
     RB / VB (emission in restricted band)       1MHz / 1MHz for Peak

     Receiver Parameter                          Setting
     Attenuation                                 Auto
     Start ~ Stop Frequency                      9kHz~150kHz / RB 200Hz for QP
     Start ~ Stop Frequency                      150kHz~30MHz / RB 9kHz for QP
     Start ~ Stop Frequency                      30MHz~1000MHz / RB 120kHz for QP

    4.2.2 TEST PROCEDURE
     a. The measuring distance of at 3 m shall be used for measurements at frequency up to 1GHz
         And above 1GHz,
     b. The EUT was placed on the top of a rotating table 0.8 meters above the ground at a 3m meter.
         The table was rotated 360 degrees to determine the position of the highest radiation.
     c. The height of the equipment or of the substitution antenna shall be 0.8 m; the height of the test
         antenna shall vary between 1 m to 4 m.
     d. The initial step in collecting conducted emission data is a spectrum analyzer peak detector
         mode pre-scanning the measurement frequency range. Significant peaks are then marked and
         then Quasi Peak detector mode re-measured.
     e. If the Peak Mode measured value compliance with and lower than Quasi Peak Mode Limit, the
         EUT shall be deemed to meet QP Limits and then no additional QP Mode measurement
         performed.
      f. For the actual test configuration, please refer to the related Item –EUT Test Photos.
         Note:
         Both horizontal and vertical antenna polarities were tested
         and performed pretest to three orthogonal axis. The worst case emissions were reported

    4.2.3 DEVIATION FROM TEST STANDARD
    No deviation




`


                                                Page 19 of 27   Report No.: S19010703501001




    4.2.4 TEST SETUP

    (A)Radiated Emission Test-Up Frequency Below 30MHz




    (B)Radiated Emission Test-Up Frequency 30MHz~1GHz




`


                                                        Page 20 of 27    Report No.: S19010703501001


    4.2.5 TEST RESULTS (BELOW 30MHz)

                      SMART CARD READER/WRITER
     EUT:                                      Model Name. : DP700S
                      FOR RFID SYSTEM
                                               Relative
     Temperature:     20 ℃                                    54%
                                               Humidtity:
     Pressure:        1010 hPa                 Test Voltage : DC 5V
     Test Mode :     TX-13.56MHz
    Measurement Plot (Polarity: X):




    Measurement Result:
                           Pre-scan Level   Final Test Level         Limit
          Frequency                                                                   Margin
                             MaxPeak           MaxPeak              MaxPeak
             MHz                                                                       dB
                              dBuV/m            dBuV/m              dBuV/m
            13.561              71.9              69.8               124.0             54.2


    Measurement Plot (Polarity: Y):




    Measurement Result:
                           Pre-scan Level   Final Test Level         Limit
          Frequency                                                                   Margin
                             MaxPeak           MaxPeak              MaxPeak
             MHz                                                                       dB
                              dBuV/m            dBuV/m              dBuV/m
            13.240              72.8              52.1                80.5             28.4




`


                                                                  Page 21 of 27       Report No.: S19010703501001


    Measurement Plot (Polarity: Z):




    Measurement Result:
                           Pre-scan Level             Final Test Level         Limit
          Frequency                                                                                 Margin
                             MaxPeak                     MaxPeak              MaxPeak
             MHz                                                                                     dB
                              dBuV/m                      dBuV/m              dBuV/m
            13.240              72.3                        42.4                80.5                 38.1

    Spurious emissions at 9kHz~30MHz
                                                             Measurement
          Frequency                   Measurement
                       Frequency                                  results         Limits   Margin Detector
            Range                           results
                                                              (calculated)
                                            dBμV                 dBμV/m       dBμV/m
            (MHz)        (MHz)                                                              (dB)
                                            @3m                    &30m       @30m
         0.490-1.705      1.157             28.45                  18.45          26.34    -7.89     QP
          1.705-30.0      5.291             21.66                  11.66          29.54    -17.88    QP
          1.705-30.0    21.654              31.34                  21.34          29.54     -8.2     QP

    Note: field strength@30m= field strength@3m+20log(3/30)




`


                                                       Page 22 of 27     Report No.: S19010703501001


    4.2.6 TEST RESULTS (BETWEEN 30 – 1000 MHZ)

                     SMART CARD
    EUT:             READER/WRITER FOR RFID       Model Name :           DP700S
                     SYSTEM
    Temperature:     20 ℃                         Relative Humidity: 54%
    Pressure:        1010 hPa                     Test Voltage :     DC 5V
    Test Mode :      TX                           Polarization :     Horizontal


            Freq.     Reading      Factor    Measurement        Limit        Over
                                                                                      Detector
           (MHz)     (dBμV/m)       (dB)      (dBμV/m)        (dBμV/m)       (dB)
         135.51       23.54        13.37       36.91            43.50        -6.59       QP
         244.23       20.93        13.83       34.76            46.00       -11.24       QP
         312.18       20.33        16.38       36.71            46.00        -9.29       QP
         393.47       19.33        19.21       38.54            46.00        -7.46       QP
         420.58       19.50        20.32       39.82            46.00        -6.18       QP
         979.18       12.00        31.02       43.02            54.00       -10.98       QP
    Remark:
     Factor = Antenna Factor + Cable Loss.




`


                                                       Page 23 of 27     Report No.: S19010703501001



                     SMART CARD
    EUT:             READER/WRITER FOR RFID       Model Name :           DP700S
                     SYSTEM
    Temperature:     20 ℃                         Relative Humidity: 54%
    Pressure:        1010 hPa                     Test Voltage :     DC 5V
    Test Mode :      TX                           Polarization :     Vertical


            Freq.     Reading      Factor    Measurement        Limit        Over
                                                                                      Detector
           (MHz)     (dBμV/m)       (dB)      (dBμV/m)        (dBμV/m)       (dB)
          95.09       16.95        11.12       28.07            43.50       -15.43       QP
         135.51       26.22        13.37       39.59            43.50        -3.91       QP
         150.01       17.91        12.77       30.68            43.50       -12.82       QP
         244.23       18.67        13.83       32.50            46.00       -13.50       QP
         420.58       17.09        20.32       37.41            46.00        -8.59       QP
         952.09       11.64        31.13       42.77            46.00        -3.23       QP
    Remark:
     Factor = Antenna Factor + Cable Loss.




`


                                                       Page 24 of 27    Report No.: S19010703501001



    5. BANDWIDTH TEST


    5.1 TEST PROCEDURE

    1. The transmitter output (antenna port) was connected to the spectrum analyzer in peak mode.
    2. 20dB Bandwidth the resolution bandwidth of 1 kHz and the video bandwidth of 1 kHz were
    used.
    3. Measured the spectrum width with power higher than 20dB below carrier.

    5.2 DEVIATION FROM STANDARD

    FCC Part15.225

    5.3 TEST SETUP




`


                                             Page 25 of 27    Report No.: S19010703501001


    5.4 TEST RESULTS

                   SMART CARD
    EUT:           READER/WRITER FOR RFID Model Name :       DP700S
                   SYSTEM
    Temperature:   26 ℃                   Relative Humidity: 54%
    Pressure:      1020 hPa               Test Power :       DC 5V
    Test Mode :    TX


                                      Frequency          20 dBc Bandwidth
                   Test Channel
                                        (MHz)                 (kHz)
                       CH01             13.56                 3.734




`


                                                          Page 26 of 27     Report No.: S19010703501001



    6. FREQUENCY TOLERANCE

    6.1 Requirement:
    Test                 FCC Part15.225
    Requirement:
    Test Method:         ANSI C63.4:2003
    Requirement:         The frequency tolerance of the carrier signal shall be maintained
                         within +/- 0.01% of the operating frequency over a temperature
                         variation of –20 degrees to +50 degrees C at normal supply
                         voltage, and for a variation in the primary supply voltage from
                         85% to 115% of the rated supply voltage at a temperature of 20
                         degrees C. For battery operated equipment, the equipment tests
                         shall be performed using a new battery.

    6.2 Test Procedure
              1.The EUT was placed on a turn table which is 0.8m above ground plane.
              2.Set EUT as normal operation
              3.Set SPA Center Frequency = fundamental frequency, RBW, VBW= 10kHz, Span
              =100kHz.
              4.Set SPA Max hold. Mark peak.




`


                                                Page 27 of 27         Report No.: S19010703501001



    Test Result


         Power                  Measured     Frequency
                  Temperature                               Result             Part 15.225
         Supply                 Frequency      Error
                     (℃)                                        (%)               Limit
                                 (MHz)         (MHz)
                      -20       13.561302    0.001302     0.009602              +/- 0.01%

         DC 5V        20        13.561301    0.001301     0.009594              +/- 0.01%

                      50        13.561291    0.001291     0.009521              +/- 0.01%

                      -20       13.561102    0.001102     0.008127              +/- 0.01%

        DC 4.5V       20        13.561103    0.001103     0.008134              +/- 0.01%

                      50        13.561101    0.001101     0.008119              +/- 0.01%

                      -20       13.561111     0.001111    0.008193              +/- 0.01%

        DC 5.5V       20        13.561115     0.001115    0.008223              +/- 0.01%

                      50        13.561112     0.001112    0.008201              +/- 0.01%




                                         END REPORT




`



Document Created: 2019-02-14 11:10:12
Document Modified: 2019-02-14 11:10:12

© 2024 FCC.report