Test Report

FCC ID: XKB-PP30S

Test Report

Download: PDF
FCCID_1201401

Rapport d’essai / Test report                                                                                                  Portée
                                                                                                                           disponible sur              Laboratoire
JDE : 95767                     N° 200909-5715C-R1-E                                                                       www.cofrac.fr            d’essai accrédité
                                                                                                                                                        N°1-1633



DELIVRE A / ISSUED TO                                    : INGENICO
                                                           Rue Claude Chappe
                                                           B.P. 344
                                                           07503 GUILHERAND GRANGES
Objet / Subject                                          : Essais de compatibilité électromagnétique conformément aux normes :
                                                           Electromagnetic compatibility tests according to the standards:
                                                           FCC CFR 47 Part 15, Subpart B.
                                                           ANSI C63.4 (2003)

Matériel testé / Apparatus under test                    :
 •  Produit / Product                                    :    Pavé numérique / Pin pad
 •  Marque / Trade mark                                  :    INGENICO
 •  Constructeur / Manufacturer                          :    INGENICO
 •  Type / Model                                         :    PP30S-110-01
 •  N° de série / serial number                          :    09290PP10000100
 •  FCC ID :                                             :    XKB-PP30S
                                                                                                              th
Date des essais / Test date                              : Le 28 Octobre 2009 / October 28 , 2009

Lieu d’essai / Test location                             : BUREAU VERITAS LCIE SUD-EST
                                                           ZI Centr’Alp – 170 rue de Chatagnon
                                                           38430 MOIRANS - France

Test réalisé par / Test performed by                     : Anthony MERLIN

document comporte / Composition of document: 17 pages

                                                                                            MOIRANS, LE 5 NOVEMBRE 2009 / NOVEMBER 5TH, 2009

 Ecrit par / Written by                                                                     Approuvé par / Approved by,
 Anthony MERLIN                                                                             Yannick SAVOIE




 La reproduction de ce document n'est autorisée que sous sa forme intégrale. Toute reproduction partielle ou toute insertion de résultats dans un texte
 d'accompagnement en vue de leur diffusion doit recevoir un accord préalable et formel du LCIE. Ce document résulte d’essais effectués sur un spécimen, un échantillon
 ou une éprouvette. Il ne préjuge pas de la conformité de l’ensemble des produits fabriqués à l’objet essayé. Sauf indication contraire, la décision de conformité prend en
 compte l’incertitude de mesures. Il ne préjuge en aucun cas d’une décision de certification. Seuls certains essais rapportés dans ce document sont couverts par
 l’accréditation. Ils sont identifiés par le symbole.
 This document shall not be reproduced, except in full, without t he written approval of the LCIE. This document contains results related only to the item tested. It does not
 imply the conformity of the whole production to the item tested .Unless otherwise specified; the decision of conformity takes into account the uncertainty of measures.
 This document does not anticipate any certification decision. Only certain tests mentioned in this document are covered by the accreditation. They are identified by the
 symbol.


                               RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E                                               Page : 2 / 17




                                                                 SUMMARY



1.   TEST PROGRAM ................................................................................................................................... 3
2.   APPARATUS UNDER TEST: CONFIGURATION ................................................................................... 4
3.   MEASUREMENT OF CONDUCTED EMISSION (150KHZ-30MHZ) ....................................................... 5
4.   MEASUREMENT OF RADIATED EMISSION (30MHZ-1GHZ)................................................................ 7
5.   TEST EQUIPMENT LIST ...................................................................................................................... 11
6.   UNCERTAINTIES CHART .................................................................................................................... 13
7.   ANNEX 1 (GRAPHS) ............................................................................................................................ 14


                         RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E                   Page : 3 / 17



1.     TEST PROGRAM

Standard:            - FCC Part 15, Subpart B (Digital Devices)
                     - ANSI C63.4 (2003)

EMISSION TEST                               LIMITS                                RESULTS
                                                                                  (Comments)
Limits for conducted disturbance at mains                Quasi-peak     Average      COMPLY
                                            Frequency
ports                                                    value (dBµV)   value (dBµV)
150kHz-30MHz                               150-500kHz       66 to 56      56 to 46
                                            0.5-5MHz            56           46
                                            5-30MHz             60           50
Radiated emissions                          Measure at 3m                            COMPLY
30MHz-1GHz*                                30MHz-88MHz : 40 dBµV/m
                                            88MHz-216MHz : 43.5 dBµV/m
                                            216MHz-960MHz : 46.0 dBµV/m
                                            Above 960MHz : 54.0 dBµV/m

* Highest internal frequency: 57MHz


                             RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E                       Page : 4 / 17



2.         APPARATUS UNDER TEST: CONFIGURATION

2.1.       HARDWARE IDENTIFICATION (EUT AND AUXILIARIES):

       •   Equipment under test (EUT):

           PP30S-110-01                                       Serial Number: 09290PP10000100


       •   Inputs/outputs:

- USB port


       •   Cables:

- USB cable, shielded, length: 1.20m


       •   Auxiliaries equipment used during test:

Trade Mark – Model Number                                FCC ID    Description            Cable description
(Serial number)
TOSHIBA SATELITE S1410-704 (PS141E-04YCM-3V)             None      Laptop                 Power cable unshielded
sn: 13594938G
Power supply unit (PA3201U-1ACA SEB100P2-15.0)           None      Adaptor AC/DC          Power cable unshielded


2.2.       RUNNING MODE

- EUT is powered by USB of laptop
- The software wintest v02.00 running
- The test sequence is performed in loop, read and verification of data on PP30S memory


2.3.       EQUIPMENT MODIFICATIONS

None


2.4.       SPECIAL ACCESSORIES

None


                         RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E                        Page : 5 / 17



3.     MEASUREMENT OF CONDUCTED EMISSION (150KHZ-30MHZ)

3.1.   TEST CONDITIONS
                                   th
Date of test           : October 28 , 2009
Test performed by      : A.MERLIN
Humidity               : 38%


3.2.   SETUP FOR CONDUCTED EMISSIONS MEASUREMENT

The product has been tested according to ANSI C63.4-(2003) and FCC Part 15 subpart B.

The product has been tested with 110V/60Hz power line voltage on laptop power supply and compared to the FCC Part
15 subpart B §15.107 limits. Measurement bandwidth was 9kHz from 150 kHz to 30 MHz.

The EUT with its auxiliaries are set on a non-conducting 80cm above the ground reference plane.
The distance between the EUT and the LISN is 80cm. The EUT is 40cm away for the vertical ground plane.
The EUT is powered through the laptop that is powered through the LISN (measure).

Measurement is made with a Rohde & Schwarz ESU8 receiver in peak mode. This was followed by a Quasi-Peak, i.e.
CISPR measurement for any strong signal. If the average limit is met when using a Quasi-Peak detector, the EUT shall
be deemed to meet both limits and measurement with the average detector is unnecessary. The LISN (measure and
auxiliaries) is 50Ω / 50µH.

The Peak data are shown on plots in annex 1. Quasi-Peak and Average measurements are detailed in a table with
frequencies and levels measured.

Interconnecting cables and equipment's were moved to position that maximized emission. A summary of the worst case
emissions found in all test configurations and modes is shown on the following page.


                         RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E                 Page : 6 / 17




3.3.   DIVERGENCE, ADDITION OR SUPPRESSION ON THE TEST SPECIFICATION

None


3.4.   MEASUREMENTS RESULTS

 Mains terminals 110Vac/60Hz:
Measurements are performed on the phase (L1) and neutral (N) of the power line of the PC.

Measure on L1: graph Emc#1                            (see annex 1)
Measure on N: graph Emc#2                             (see annex 1)

RESULT: PASS


                          RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E                         Page : 7 / 17



4.     MEASUREMENT OF RADIATED EMISSION (30MHZ-1GHZ)

4.1.   TEST CONDITIONS
                                    th
Date of test           : October 28 , 2009
Test performed by      : A.MERLIN
Humidity               : 38%


4.2.   SETUP FOR RADIATED EMISSIONS MEASUREMENT

The installation of EUT is identical for pre-characterization measures in a 3 meters semi-anechoic chamber and for
measures on the 10 meters Open site.
The EUT and auxiliaries are set on the non-conducting table of 80 cm height.
The EUT is powered by laptop.


Pre-characterisation measurement:
A pre-scan of all the setup has been performed in a 3 meters semi-anechoic chamber. The distance between EUT and
antenna is 3 meters. Test is performed in horizontal (H) and vertical (V) polarization. During the measurement, the EUT
is rotated on a 360° range and moved in horizontal and vertical position. Interconnecting cables and equipment's were
moved to position that maximized emission. A summary of the worst case emissions found in all test configurations and
modes is shown on the following page.

The pre-characterization graphs are obtained in PEAK detection.


Characterization on 10 meters open site from 30MHz to 1GHz:
The product has been tested according to ANSI C63.4 (2003), FCC part 15 subpart B. Radiated Emissions were
measured on an open area test site. A description of the facility is on file with the FCC.


The product has been tested at a distance of 10 meters (30MHz to 1GHz) from the antenna and corrected according to
requirements of 15.109.e).
Results are compared to the FCC part 15 subpart B §15.109 limits.
Measurement bandwidth was 120kHz from 30 MHz to 1GHz.
Antenna height search was performed from 1m to 4m for both horizontal and vertical polarization. Continuous linear
turntable azimuth search was performed with 360 degrees range.


                    RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E   Page : 8 / 17




                                   Radiated emission test setup


4.3.   DIVERGENCE, ADDITION OR SUPPRESSION ON THE TEST SPECIFICATION

None


                         RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E                     Page : 9 / 17




4.4.   MEASUREMENTS RESULTS

Pre-characterisation measurement: pre-scan measurement at 3m (PEAK detection, graph examples)

               Polarisation H: graph Emr#1            (see annex 1)
               Polarisation V: graph Emr#2            (see annex 1)

QUALIFICATION: 10 / 3 meters measurement on the Open Area Test Site.

Frequency list has been created with semi-anechoic chamber pre-scan results.
Measurements are performed using a QUASI-PEAK detection.

Frequency range 30MHz to 1GHz:
Measurements are performed using a QUASI-PEAK detection (RBW=120kHz)
   No    Frequency       Limit       Measure   Margin      Angle Pol      Ht    Correc.    Comments
            (MHz)     Quasi-Peak Quasi-Peak (Meas-Lim) Table Ant. Ant.          factor
                       (dBµV/m)     (dBµV/m)     (dB)      (deg)        (cm)     (dB)
    1       33.960       40.0         35.9        -4.1      160    V     100     12.6
    2       35.747       40.0         31.6        -8.4      150    V     100     12.1
    3       47.886       40.0         34.1        -5.9        0    V     100     12.5
    4       56.681       40.0         31.6        -8.4       30    V     150     12.1
    5      117.815       43.5         32.6       -10.9       40    V     140     16.3
    6      125.752       43.5         32.8       -10.7      350    V     100     15.3
    7      298.144       46.0         34.9       -11.1       65    V     100     17.4
    8      994.275       54.0         37.2       -16.8       70    V     250     29.7
Note: Measures have been done at 10m distance and corrected according to requirements of 15.109.e)
(M@3m = M@10m+10.5dB)


RESULT: PASS


                          RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E                          Page : 10 / 17



4.5.    Field Strength Calculation

The field strength is calculated by adding the Antenna Factor and Cable Factor, and subtracting the Amplifier Gain (if
any) from the measured reading. The basic equation with a sample calculation is as follow:

FS = RA + AF + CF – AG

Where       FS = Field Strength
            RA = Receiver Amplitude
            AF = Antenna Factor
            CF = Cable Factor
            AG = Amplifier Gain

Assume a receiver reading of 52.5dBµV is obtained. The antenna factor of 7.4 and a cable factor of 1.1 is added. The
amplifier gain of 29dB is subtracted, giving field strength of 32 dBµV/m.
FS = 52.5 + 7.4 + 1.1 – 29 = 32 dBµV/m
The 32 dBµV/m value can be mathematically converted to its corresponding level in µV/m.
Level in µV/m = Common Antilogarithm [(32dBµV/m)/20] = 39.8 µV/m.


                         RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E               Page : 11 / 17



5.     TEST EQUIPMENT LIST

           N° LCIE                 TYPE                    COMPANY                 REF             SN
RADIATED EMISSION MEASUREMENT (PRE-SCAN SEMI-ANECHOIC CHAMBER #2)
           A5329032VO Absorption clamp                    LUTHI              MDS21         2826
           A5329044VO Absorption clamp                    RHODE ET SCHWARZ   85024A        194.0100.50
   X       A4049060VO Adapter quasi-peak                  HEWLETT PACKARD    HP85650A
           A7102024VO Amplifier 8 GHz                     HEROTEK            A1080304A     222033
   X       A7486006VO Amplifier 0.1MHz – 1300 MHz         HEWLETT PACKARD    8447F         3113A07116
           A7085008VO Amplifier 0.1MHz – 1300 MHz         HEWLETT PACKARD    8447D         2944A06838
           A7085009VO Amplifier 0.1MHz – 1300 MHz         HEWLETT PACKARD    8447D         2944A08871
           A7085010VO Amplifier 10MHz – 1300 MHz          A-INFO INC         JXWBLA-T
   X      C2040146VO Antenna Bi-Log XWing                 TESEQ              CBL6144       25904
          C2042027VO Antenna horn                         EMCO               3115          6382
          C2042028VO Antenna horn 26GHz                   SCHWARZBECK        BBHA 9170     BBHA9170232
          C2040052VO Antenna Loop                         ELECTRO-METRICS    EM-6879       690234
   X       A5329045VO Cable EMR (s-Anechoic chamber)
   X       A5329056VO Cable Radiat EMI (Pre-amp/Analyzer)
   X       A5329057VO Cable Radiat. EMI (Pre-amp/cage)
            A2642019   Measurement Receiver 20Hz – 8GHz ROHDE & SCHWARZ      ESU8          100131
   X       A4060030VO Pre-selector RF                     HEWLETT PACKARD    HP85685A
   X       A3169050VO Radiated emission comb generator    BARDET                           PR17B
   X      D3044015VO Semi-Anechoic chamber #2             SIEPEL
   X       A4060029VO Spectrum analyzer                   HEWLETT PACKARD    HP8568B
   X       A4060028VO Spectrum analyzer display           HEWLETT PACKARD    HP85662A
   X       F2000404VO Turntable chamber                   ETS Lingren        Model 2165          00085780
   X       F2000393VO Turntable controller chamber        ETS Lingren        Model 2066
RADIATED EMISSION MEASUREMENT (OPEN AREA TEST SITE)
           A5329032VO Absorption clamp                    LUTHI              MDS21         2826
           A5329044VO Absorption clamp                    RHODE ET SCHWARZ   85024A        194.0100.50
   X       A4049059VO Adapter quasi-peak                  HEWLETT PACKARD    HP85650A      2811A01134
           A7102024VO Amplifier 8 GHz                     HEROTEK            A1080304A     222033
           A7102026VO Amplifier 8-26GHz                   ALDETEC            ALS01452      1
           A7085008VO Amplifier 0.1MHz – 1300 MHz         HEWLETT PACKARD    8447D         2944A06838
           A7085009VO Amplifier 0.1MHz – 1300 MHz         HEWLETT PACKARD    8447D         2944A08871
           A7085010VO Amplifier 10MHz – 1300 MHz          A-INFO INC         JXWBLA-T
   X      C2040050VO Antenna biconic                      EMCO               3104C         9401-4636
          C2040051VO Antenna Bi-log                       CHASE              CBL6111A      1628
          C2042027VO Antenna horn                         EMCO               3115          6382
          C2042028VO Antenna horn 26GHz                   SCHWARZBECK        BBHA 9170     BBHA9170232
   X      C2040056VO Antenna log-periodic                 EMCO               3146          2178
          C2040052VO Antenna Loop                         ELECTRO-METRICS    EM-6879       690234
   X       F2000288VO Antenna mast                        EMCO               1050
   X       A5329048VO Cable EMR OATS                      SUCOFLEX           106G          553
   X       A5329199VO Cable OATS (Mast at 10m)            UTIFLEX
   X       A5329188VO Cable OATS (Mast at 10m)            UTIFLEX
           A5329076VO Cable OATS (Mast at 3m)             UTIFLEX
           A5329196VO Cable OATS (Turntable)              UTIFLEX
           A5329187VO Cable OATS (Turntable)              UTIFLEX
           A2640011VO Measurement receiver 9kHz–30MHz     ROHDE ET SCHWARZ   ESH3          972079/117
            A2642019   Measurement Receiver 20Hz – 8GHz ROHDE & SCHWARZ      ESU8          100131
   X       A4060027VO Pre-selector RF                     HEWLETT PACKARD    HP85685A      2837A00784
   X       A3169050VO Radiated emission comb generator    BARDET                           PR17B
   X       A4060017VO Spectrum analyzer                   HEWLETT PACKARD    HP8568B       2732A04155
           A4060018VO Spectrum Analyzer 9KHz – 26.5GHz HEWLETT PACKARD       8593E         3409u00537
           A4060016VO Spectrum analyzer 9kHz –1.8GHz      HEWLETT PACKARD    8591E         3536A00384
   X       A4060019VO Spectrum analyzer display           HEWLETT PACKARD    HP85662A      2816A16603
   X       F2000403VO Turntable                           ETS LINDGREN       Model 2187
   X       F2000286VO Turntable / Antenna mast controller ETS LINDGREN       Model 2066

CONDUCTED MEASUREMENT EMISSION
   X      A5329054VO Cable Conduct. EMI
   x      A5329060VO Cable Conduct. EMI
          A5329189VO Shielded cable                    UTIFLEX
          A5329076VO Shielded cable                    UTIFLEX


                          RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E                       Page : 12 / 17



            N° LCIE                 TYPE                      COMPANY                   REF                SN
          A5329206VO Shielded cable                        UTIFLEX
          A5329207VO Shielded cable                        UTIFLEX
          A5329060VO Shielded cable                        UTIFLEX
          A5329071VO Shielded cable                        UTIFLEX
    X     A3169049VO Conducted emission comb generator     BARDET                                    CGPR12
           A4040015   Clickmeter                           SCHAFFNER              DIA1512D           22338
          A5329037VO Current injection probe               SCHAFFNER              CIP8213            52
          A1290017VO Current probe                         SCHAFFNER              CSP9160            1097
          A5329036VO Direct Injection Module 100+50 Ohms   LCIE                   MID01-100 ohms
          A7156004VO Direct Injection Module 100+50 Ohms   LUTHI                  CR100A             221
          A5329042VO Ferrite Tube                          LUTHI                  FTC 101            4485
          A1092042VO Ferrite Tube                          LUTHI                  FTC101             4763
          C2320059VO LISN                                  EMCO                   3810/2SH           9511/1182
          C2320068VO LISN                                  EMCO                   3825/2             9309/2122
          C2320061VO LISN                                  TELEMETER ELECTRONIC   NNB-2/16Z          98010
    X     C2320062VO LISN tri-phase ESH2-Z5                RHODE ET SCHWARZ       33852.19.53        841223/008
          C2320063VO LISN tri-phase ESH2-Z5                RHODE ET SCHWARZ       33852.19.53        841223/007
          C2320123VO LISN                                  RHODE ET SCHWARZ       ENV216             100037
          A2640011VO Measurement receiver 9kHz–30MHz       ROHDE ET SCHWARZ       ESH3               972079/117
    X     A2642019VO Measurement Receiver 20Hz – 8GHz      ROHDE & SCHWARZ        ESU8               100131
          C2320067VO ISN 2 x 2 wires                       RHODE ET SCHWARZ       ENY22              836727/015
          C2320066VO ISN 4 wires                           RHODE ET SCHWARZ       ENY41              838119/023
          C2320124VO ISN 4 wires                           TESEQ                  T400A              24873
          D3044016VO Semi-Anechoic chamber #1              SIEPEL
          D3044017VO Semi-Anechoic chamber #3              SIEPEL
          D3044015VO Semi-Anechoic chamber #2              SIEPEL
    X     D3044010VO Faraday Cage                          RAY PROOF                                 4854
    X     A4049061VO Transient limiter                     HEWLETT PACKARD        11947A             3107A01596
          A4089117VO Voltage probe                         LCIE
MISCALLENOUS (CONTROL EQUIPMENT)
          A6440068VO Data Logger                           AGILENT                34970A             US37043935
          A2120003VO Programable PSU, HAR/FLK              HEWLETT PACKARD        6842A              3531A00109
          A6440068VO Data Logger Board                     AGILENT                34901A             MY41037442
          D1022117VO Climatic chamber                      BIA CLIMATIC           CL 6-25            200 105 6
          A7043037VO Power supply DC 30V 10A               ELC                    AL924              95/00600
          A1240170VO Multimeter                            Fluke                  87                 75250745
          A1240171VO Multimeter                            FLUKE                  189                89770115
          A4024018VO Oscilloscope 500 MHz                  Hewlett Packard        54542C             US36040602
          A4024019VO Oscilloscope                          Hewlett Packard        54720A             7426600
    X     B4204052VO Thermo-hygrometer                     HUGER
          A7043036VO Power supply DC 300W / 150V-6A        SODILEC                7SDLIN/GB AUTO 300 493711
          A4083040VO Oscilloscope 100 MHz 500Ms/s          Tektronix              TDS30-25           H712103


                                RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E                                           Page : 13 / 17



6.       UNCERTAINTIES CHART

                                                                                                     Incertitude élargie
                                                                                                                               Incertitude limite
                                                                                                     laboratoire /
                                                                                                                               du CISPR / CISPR
Type de mesure / Kind of measurement                                                                 Wide uncertainty
                                                                                                                               uncertainty limit ±
                                                                                                     laboratory
                                                                                                                               y
                                                                                                     (k=2) ± x
Mesure des perturbations conduites en tension sur le réseau d’énergie (triphasé)
                                                                                                             3.6 dB                    3.6 dB
Measurement of conducted disturbances in voltage on the power port (three phases)
Mesure des perturbations conduites en tension sur le réseau d’énergie (monophasé)
                                                                                                             3.57 dB                   3.6 dB
Measurement of conducted disturbances in voltage on the power port (single line)
Mesure des perturbations conduites en tension sur le réseau de télécommunication                                                    A l’étude /
                                                                                                             3.28 dB
Measurement of conducted disturbances in voltage on the telecommunication port.                                                    Under consid.
Mesure des perturbations discontinues conduites en tension
                                                                                                             3.47 dB                   3.6 dB
Measurement of discontinuous conducted disturbances in voltage
Mesure des perturbations conduites en courant                                                                                       A l’étude /
                                                                                                             2.90 dB
Measurement of conducted disturbances in current                                                                                   Under consid.
Mesure du champ électrique rayonné sur le site en espace libre de Voiron
                                                                                                             5.07 dB                   5.2 dB
Measurement of radiated electric field on the Voiron open area test site
Mesure du champ électrique rayonné IN SITU de 30 à 1000 MHz                                               A l’étude /
                                                                                                                                       5.2 dB
IN SITU measurement of radiated electric field from 30 to 1000MHz                                     Under consideration
Mesure de la puissance perturbatrice / Measurement of disturbance power                                    3.37 dB                     4.5 dB
Mesure des harmoniques de courant / Measurement of current harmonics                                       11.11%                         /
Mesure du flicker / Flicker measurement                                                                     9.26%                         /

Les valeurs d’incertitudes calculées du laboratoire étant inférieures aux valeurs d’incertitudes limites établies par le CISPR, la conformité de
l’échantillon est établie directement par les niveaux limites applicables. / The uncertainty values calculated by the laboratory are lower than limit
uncertainty values defined by the CISPR. The conformity of the sample is directly established by the applicable limits values.


                                    RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E                Page : 14 / 17



7.        ANNEX 1 (GRAPHS)


                CONDUCTED EMISSIONS                         Test configuration:
     Graph name:          Emc#1
     Voltage / Frequency  110VAC/60Hz
     Line/Port            Phase L1                             Peak Measure           QPeak Limit
     RBW / VBW :          9kHz / 30kHz                         Average Measure        Average Limit
         100
     dBµV




          0
               150kHz                                                                                             30MHz
                                                                Fréquence                                   Sous-bande 1




                        Frequency      Avg    Lim Avg   Avg-LimAvg     QPeak    LimQPeak   QPeak-LimQPeak
                          (MHz)      (dBµV)   (dBµV)      (dBµV)       (dBµV)     (dBµV)       (dBµV)
                          0.166       31.20    55.16      -23.96        39.72      65.16       -25.44
                          0.502       30.51      46       -15.49        38.95       56         -17.05


                               RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E                Page : 15 / 17




           CONDUCTED EMISSIONS                         Test configuration:
Graph name:          Emc#2
Voltage / Frequency  110VAC/60Hz
Line/Port            Neutral N                            Peak Measure           QPeak Limit
RBW / VBW :          9kHz / 30kHz                         Average Measure        Average Limit
    100
dBµV




     0
          150kHz                                                                                             30MHz
                                                           Fréquence                                   Sous-bande 1




                   Frequency      Avg    Lim Avg   Avg-LimAvg     QPeak    LimQPeak   QPeak-LimQPeak
                     (MHz)      (dBµV)   (dBµV)      (dBµV)       (dBµV)     (dBµV)       (dBµV)
                     0.166       37.03    55.16      -18.13        45.39      65.16       -19.77
                     0.502       29.62      46       -16.38        38.78       56         -17.22


                    RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E                Page : 16 / 17




            RADIATED EMISSION             Test configuration:
Graph name:          Emr#1
Antenna position:    Horizontal
Azimuth:             0° - 360°
RBW/VBW:             120kHz / 300kHz         Peak Measure            QPeak Limit@3m
      100
dBµV/m




       0
            30MHz                                                                              1.001GHz
                                                  Fréquence                                 Sous-bande 1




                                Frequency (MHz)      Peak (dBµV/m)
                                     36.84               25.45
                                      81.8               23.94
                                     108.12              25.06
                                     119.84              25.95
                                      168                26.58
                                     179.92              27.67
                                     298.64              27.95
                                     500.92              30.71


                    RAPPORT D'ESSAI / TEST REPORT N° 200909-5715C-R1-E                Page : 17 / 17




            RADIATED EMISSION             Test configuration:
Graph name:          Emr#2
Antenna position:    Vertical
Azimuth:             0° - 360°
RBW/VBW:             120kHz / 300kHz         Peak Measure            QPeak Limit@3m
      100
dBµV/m




       0
            30MHz                                                                              1.001GHz
                                                  Fréquence                                 Sous-bande 1




                                Frequency (MHz)      Peak (dBµV/m)
                                       34                37.66
                                     35.76               36.23
                                     47.92               29.94
                                     56.72               31.06
                                     117.76              29.28
                                     125.6               28.94
                                     298.2                34.1
                                     498.28              30.12
                                     695.92              32.27
                                     994.28              40.27



Document Created: 2009-11-10 17:57:13
Document Modified: 2009-11-10 17:57:13

© 2024 FCC.report