                                                Test report no.: 1-8662/19-02-12                                                           D-PL-12076-01-03

       BNetzA-CAB-02/21-102



                     Testing laboratory                                                             Applicant
 CTC advanced GmbH                                                               Ingenico Group
 Untertuerkheimer Strasse 6 – 10                                                 9 Avenue de la Gare Rovaltain
 66117 Saarbruecken / Germany                                                    26958 Valence Cedex 9 / FRANCE
 Phone:    + 49 681 5 98 - 0                                                     Phone:   -/-
 Fax:      + 49 681 5 98 - 9075                                                  Contact: Nicolas Jacquemont
 Internet: http://www.ctcadvanced.com                                            e-mail:  nicolas.jacquemont@ingenico.com
 e-mail:   mail@ctcadvanced.com                                                  Phone:   +33475842123

 Accredited Testing Laboratory:
 The testing laboratory (area of testing) is accredited
 according to DIN EN ISO/IEC 17025 (2005) by the
 Deutsche Akkreditierungsstelle GmbH (DAkkS)                                                      Manufacturer
 The accreditation is valid for the scope of testing                             Ingenico Group
 procedures as stated in the accreditation certificate with                      9 Avenue de la Gare Rovaltain
 the registration number: D-PL-12076-01-03                                       26958 Valence Cedex 9 / FRANCE


                                                                 Test standard/s
 47 CFR Part 15                Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio frequency
                               devices
 RSS - 247 Issue 2             Digital Transmission Systems (DTSs), Frequency Hopping Systems (FHSs) and
                               Licence - Exempt Local Area Network (LE-LAN) Devices
 For further applied test standards please refer to section 3 of this test report.


                                                                          Test Item
 Kind of test item:           Android Point of sales Terminal
 Model name:                  Lane/5000 CL/Eth/WiFi/BTv3
 FCC ID:                      2586D-L5KCLWBTV3
 IC:                          XKB-L5KCLWBTV3
                              UNII bands:
 Frequency:                   5150 MHz to 5250 MHz; 5250 MHz to 5350 MHz;
                              5470 MHz to 5725 MHz; 5725 MHz to 5850 MHz
 Technology tested:           WLAN (DFS only)
 Antenna:                     Integrated PCB antenna
 Power supply:                115 V AC & 5 V DC by mains adapter
 Temperature range:           0°C to +45°C

This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures,
the public keys can be requested at the testing laboratory.


 Test report authorized:                                                       Test performed:
                               cn=Mihail Dorongovskij, o=CTC advanced                                    Digital unterschrieben von David Lang
                               GmbH, ou=DOR-281116,                                                      DN: cn=David Lang, o=CTC advanced GmbH,
                               email=Mihail.Dorongovskij@ctcadvanced.co                                  ou=LNG-161129, email=david.lang@ctcadvanced.com,
                               m, c=DE                                                                   c=DE
                               2019.08.07 08:18:32 +02'00'                                               Datum: 2019.08.07 09:29:06 +02'00'


 Mihail Dorongovskij                                                           David Lang
 Lab Manager                                                                   Lab Manager
 Radio Communications & EMC                                                    Radio Communications & EMC


                   Test report no.: 1-8662/19-02-12



1      Table of contents

1    Table of contents ............................................................................................................................................2
2    General information .......................................................................................................................................3
     2.1         Notes and disclaimer.........................................................................................................................3
     2.2         Application details .............................................................................................................................3
     2.3         Test laboratories sub-contracted .....................................................................................................3
3    Test standard/s and references ....................................................................................................................4
4    Test environment............................................................................................................................................5
5    Test item ..........................................................................................................................................................5
     5.1         General description ...........................................................................................................................5
     5.2         Additional information ......................................................................................................................5
6    Measurement uncertainty ..............................................................................................................................6
7    Summary of measurement results ...............................................................................................................6
8    Additional comments .....................................................................................................................................7
9    RF measurements ..........................................................................................................................................8
     9.1         Description of test setup...................................................................................................................8
     9.1.1       Conducted measurements...................................................................................................................8
     9.2         Parameters of DFS test signals ......................................................................................................10
     9.2.1       DFS Detection Thresholds for Master Devices as well as Client Devices With Radar Detection .....10
     9.2.2       DFS Response Requirement Values .................................................................................................10
     9.2.3       Radar Test Waveforms ......................................................................................................................11
     9.3         Test preparation ...............................................................................................................................14
     9.3.1       Channel loading .................................................................................................................................14
     9.3.2       Radar burst timing signal ...................................................................................................................15
     9.4         Test results (prior to use of a channel) .........................................................................................16
     9.5         Test results (during normal operation) .........................................................................................16
     9.5.1       Channel move time / channel closing transmission time ...................................................................16
     9.5.2       Non-Occupancy Period......................................................................................................................18
10       Observations ............................................................................................................................................19
Annex A          Glossary............................................................................................................................................19
Annex B          Document history ............................................................................................................................20
Annex C          Accreditation Certificate – D-PL-12076-01-04 ...............................................................................20
Annex D          Accreditation Certificate – D-PL-12076-01-05 ...............................................................................21




© CTC advanced GmbH                                                                                                                                     Page 2 of 21


              Test report no.: 1-8662/19-02-12




2      General information

2.1    Notes and disclaimer
The test results of this test report relate exclusively to the test item specified in this test report. CTC advanced
GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with
regard to other specimens or samples of the type of the equipment represented by the test item.
The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report
requires the prior written approval of CTC advanced GmbH.
The testing service provided by CTC advanced GmbH has been rendered under the current "General Terms and
Conditions for CTC advanced GmbH".
CTC advanced GmbH will not be liable for any loss or damage resulting from false, inaccurate, inappropriate or
incomplete product information provided by the customer.
Under no circumstances does the CTC advanced GmbH test report include any endorsement or warranty
regarding the functionality, quality or performance of any other product or service provided.
Under no circumstances does the CTC advanced GmbH test report include or imply any product or service
warranties from CTC advanced GmbH, including, without limitation, any implied warranties of merchantability,
fitness for purpose, or non-infringement, all of which are expressly disclaimed by CTC advanced GmbH.
All rights and remedies regarding vendor’s products and services for which CTC advanced GmbH has prepared
this test report shall be provided by the party offering such products or services and not by CTC advanced GmbH.
In no case this test report can be considered as a Letter of Approval.

This test report is electronically signed and valid without handwritten signature. For verification of the electronic
signatures, the public keys can be requested at the testing laboratory.



2.2    Application details
Date of receipt of order:                2017-11-13
Date of receipt of test item:            2018-01-22
Start of test:                           2018-02-01
End of test:                             2018-02-01
Person(s) present during the test:       -/-



2.3    Test laboratories sub-contracted
None




 © CTC advanced GmbH                                                                                     Page 3 of 21


            Test report no.: 1-8662/19-02-12




3    Test standard/s and references
Test standard            Date           Description
47 CFR Part 15                          Title 47 of the Code of Federal Regulations; Chapter I; Part 15 -
                                        Radio frequency devices
RSS - 247 Issue 2        February       Digital Transmission Systems (DTSs), Frequency Hopping
                         2017           Systems (FHSs) and Licence - Exempt Local Area Network (LE-
                                        LAN) Devices
                                        Spectrum Management and Telecommunications Radio Standards
RSS - Gen Issue 5        April 2018     Specification
                                        - General Requirements for Compliance of Radio Apparatus



Guidance                 Version        Description

                                        Guidelines for Compliance Testing of Unlicensed National
UNII: KDB 789033 D02     v02r01
                                        Information Infrastructure (U-NII) Devices - Part 15, Subpart E
                                        American national standard of procedures for compliance testing
ANSI C63.10-2013         -/-
                                        of unlicensed wireless devices
                                        Compliance measurement procedures for unlicensed - national
                                        information infrastructure devices operating in the 5250 - 5350
UNII: KDB 905462 D02     v02
                                        MHz and 5470 - 5725 MHz bands incorporating dynamic
                                        frequency selection
UNII: KDB 905462 D03     v01r02         Client Without DFS New Rules
UNII: KDB 905462 D04     v01            Operational Modes for DFS Testing New Rules




© CTC advanced GmbH                                                                              Page 4 of 21


              Test report no.: 1-8662/19-02-12




4     Test environment

                                   Tnom    +22 °C during room temperature tests
Temperature                  :     Tmax    No tests under extreme temperature conditions required.
                                   Tmin    No tests under extreme temperature conditions required.
Relative humidity content    :             55 %
Barometric pressure          :             1021 hpa
                                   Vnom    115 V AC & 5 V DC by mains adapter
Power supply                 :     Vmax    No tests under extreme voltage conditions required.
                                   Vmin    No tests under extreme voltage conditions required.



5     Test item

5.1   General description

Kind of test item            :   Android Point of sales Terminal
Type identification          :   Lane/5000 CL/Eth/WiFi/BTv3
HMN                          :   -/-
PMN                          :   Lane/5000
HVIN                         :   Lane/5000 CL/Eth/WiFi/BTv3
FVIN                         :   -/-
S/N serial number            :   Conducted unit:         170899913261044599999921
HW hardware status           :   01
SW software status           :   OS_038105_HTB_0086; RF test mode
                                 UNII bands:
Frequency band               :   5150 MHz to 5250 MHz; 5250 MHz to 5350 MHz;
                                 5470 MHz to 5725 MHz; 5725 MHz to 5850 MHz
Type of radio transmission :
                                 OFDM
Use of frequency spectrum :
Type of modulation         :     (D)BPSK, (D)QPSK, 16 – QAM, 64 – QAM
                                 20 MHz: 24
Number of channels           :
                                 40 MHz: 11
Antenna                      :   Integrated PCB antenna
Power supply                 :   115 V AC & 5 V DC by mains adapter
Temperature range            :   0°C to +45°C


5.2   Additional information
The content of the following annexes is defined in the QA. It may be that not all of the listed annexes are
necessary for this report, thus some values in between may be missing.

Test setup and EUT photos are included in test report:           1-8662/19-02-01_AnnexA




 © CTC advanced GmbH                                                                                   Page 5 of 21


                    Test report no.: 1-8662/19-02-12




6         Measurement uncertainty

                                                  Measurement uncertainty
                            Test case                                                               Uncertainty
 Frequency accuracy (radar burst)                                              0.1 Hz
 Level accuracy (radar burst)                                                  ± 0.8 dB


7         Summary of measurement results

          ☒            No deviations from the technical specifications were ascertained

          ☐            There were deviations from the technical specifications ascertained
                       This test report is only a partial test report.
          ☒            The content and verdict of the performed test cases are listed below.



TC Identifier                           Description                           Verdict                Date              Remark
    DFS-Testing                   CFR Part 15, FCC 06-96                       Pass                2019-08-07         DFS only



     Test Standard
                                           Test Case                       Bandwidth           C     NC     NA    NP     Remark
        Clause
          7.8.1*3                  U-NII Detection Bandwidth                    -/-          ☐        ☐     ☒     ☐        *1*2*3

      §15.407 (h)(2)                DFS Detection Threshold                     -/-          ☐        ☐     ☒     ☐        *1*2*3

 §15.407 (h)(2) (ii)
         &                      Channel Availability Check Time                 -/-          ☐        ☐     ☒     ☐         *1*3
      7.8.2*3
 §15.407 (h)(2) (iv)
         &                           Non-Occupancy Period                    40 MHz          ☒        ☐     ☐     ☐          *2
      7.8.3*3
    §15.407 (h)(2) (iii)
                             Channel Move Time / Channel Closing
            &
                                     Transmission Time
                                                                             40 MHz          ☒        ☐     ☐     ☐          *2
         7.8.2*3
                                     In-Service Monitoring /
     7.8.3 & 7.8.4*3
                                 Statistical Performance Check
                                                                                -/-          ☐        ☐     ☒     ☐         *2*3


Abbreviations/References:

 C           Compliant
 NC          Not compliant
 NA          Not applicable
 NP          Not performed
 *1          Prior to use of a channel
 *2          During normal operation
 *3          Not applicable for Client Devices without radar detection.




 © CTC advanced GmbH                                                                                                   Page 6 of 21


              Test report no.: 1-8662/19-02-12




8     Additional comments
Reference documents:          None


Special test descriptions:    All tests except the In-Service Monitoring are conducted with Pulse Type 0.

                              A sample with temporary antenna connector was provided to perform the
                              measurements in a conducted way.



Configuration descriptions:   Iperf was used to generate the required channel load (duty cycle greater 17
                              percent).

DFS functionality:            ☐ Master device
                              ☐ Client with radar detection
                              ☒ Client without radar detection




 © CTC advanced GmbH                                                                              Page 7 of 21


              Test report no.: 1-8662/19-02-12




9       RF measurements

9.1     Description of test setup

9.1.1 Conducted measurements
Setup

Figure 1 shows a setup whereby the UUT is a RLAN device operating in slave mode, without Radar Interference
Detection function. This setup also contains a RLAN device operating in master mode. The radar test signals
are injected into the master device. The UUT (slave device) is associated with the master device.

Figure 1 shows an example




                                                 Figure 1: Setup

RPP = SG - CA
(RPP-radar pulse power; SG-signal generator power; CA-loss signal path)

Example calculation:
RPP [dBm] = -30.0 [dBm] – 33.0 [dB] = -63.0 [dBm]




 © CTC advanced GmbH                                                                            Page 8 of 21


                  Test report no.: 1-8662/19-02-12




Typically, the calibrations of the test apparatus are commissioned to and performed by an accredited calibration
laboratory. The calibration intervals are determined in accordance with the DIN EN ISO/IEC 17025. In addition to
the external calibrations, the laboratory executes comparison measurements with other calibrated test systems
or effective verifications. Weekly chamber inspections and range calibrations are performed. Where possible, rf-
generating and signalling equipment as well as measuring receivers and analyzers are connected to an external
high-precision 10 MHz reference (GPS-based or rubidium frequency standard).

In order to simplify the identification of the equipment used at some special tests, some items of test equipment
and ancillaries can be provided with an identifier or number in the equipment list below (Lab/Item).


Equipment table:

          Lab /                                                                                                   Kind of       Last        Next
  No.                Equipment                Type             Manufacturer             Serial No.    INV. No.
          Item                                                                                                   Calibration Calibration Calibration
                    Vector Signal
  1        A                               SMU200A                  R&S                  101633      300003496       k       24.01.2017   23.01.2020
                      Generator
                  Spectrum Analyzer
  2        A       9kHz to 30GHz -           FSP30                  R&S                  100886      300003575       k       24.01.2017   23.01.2019
                    140..+30dBm
                                      div. Splitter, Cables,
  3        A        DFS-test site                               Mini-Circuits              na        300004557       ev          -/-          -/-
                                           Attenuators
                                        Latitude 15 6000
  4        A          Notebook                                      Dell                             300004737       ne          -/-          -/-
                                              Series
                  Dual Band Gigabit
  5        A*                             RT-AC68U                 Asus               F1IMOH056666   400001244       ne          -/-          -/-
                       Router
                   RF-Cable DFS-      ST18/SMAm/SMAm/                                   Batch no.
  6        A                                                   Huber & Suhner                        400001252       ev          -/-          -/-
                   Tester Receiver           24                                         1308650
                   RF-Cable DFS-                                                        Batch no.
  7        A                           Enviroflex 316 D        Huber & Suhner                        400001257       ev          -/-          -/-
                    Tester No. 1                                                        1560522
                   RF-Cable DFS-                                                        Batch no.
  8        A                           Enviroflex 316 D        Huber & Suhner                        400001262       ev          -/-          -/-
                    Tester No. 6                                                        1560522
  9        A        Shielding Box          JRE2218             JRE Test LLC             0001110      400001265       ne          -/-          -/-


* FCC ID: MSQ-RTAC68U

Agenda: Kind of Calibration

  k        calibration / calibrated                                             EK      limited calibration
  ne       not required (k, ev, izw, zw not required)                           zw      cyclical maintenance (external cyclical
                                                                                        maintenance)
  ev       periodic self verification                                           izw     internal cyclical maintenance
  Ve       long-term stability recognized                                       g       blocked for accredited testing
  vlkI!    Attention: extended calibration interval
  NK!      Attention: not calibrated                                            *)      next calibration ordered / currently in progress




 © CTC advanced GmbH                                                                                                                   Page 9 of 21


             Test report no.: 1-8662/19-02-12



9.2   Parameters of DFS test signals

9.2.1 DFS Detection Thresholds for Master Devices as well as Client Devices With
      Radar Detection

                                                                                   Value
             Maximum Transmit Power EIRP
                                                                                 (see note)

                         ≥ 200 mW                                                 -64 dBm

                         < 200 mW and
                                                                                      -62 dBm
             power spectral density < 10 dBm/MHz
                         < 200 mW and
                                                                                      -64 dBm
 That do not meet the power spectral density < 10 dBm/MHz
  Note 1: This is the level at the input of the receiver assuming a 0 dBi receive antenna.
  Note 2: Throughout these test procedures an additional 1 dB has been added to the amplitude of the test
  transmission waveforms to account for variations in measurement equipment. This will ensure that the test
  signal is at or above the detection threshold level to trigger a DFS response.
  Note3: EIRP is based on the highest antenna gain. For MIMO devices refer to KDB Publication 662911
  D01.


9.2.2 DFS Response Requirement Values

                      Parameter                                                 Value

                Non-occupancy period                                     minimum 30 minutes

           Channel Availability Check Time                                   60 seconds

                                                                             10 seconds
                 Channel Move Time
                                                                             See Note 1.
                                                          200 milliseconds + an aggregate of 60 milliseconds
         Channel Closing Transmission Time                         over remaining 10 second period.
                                                                          See Notes 1 and 2.
                                                            Minimum 100% of the U-NII 99% transmission
              U-NII Detection Bandwidth
                                                                     power bandwidth. See Note 3.

  Note 1: Channel Move Time and the Channel Closing Transmission Time should be performed with Radar
          Type 0. The measurement timing begins at the end of the Radar Type 0 burst.
  Note 2: The Channel Closing Transmission Time is comprised of 200 milliseconds starting at the beginning
          of the Channel Move Time plus any additional intermittent control signals required to facilitate a
          Channel move (an aggregate of 60 milliseconds) during the remainder of the 10 second period.
          The aggregate duration of control signals will not count quiet periods in between transmissions.
  Note 3: During the U-NII Detection Bandwidth detection test, radar type 0 should be used. For each
          frequency step the minimum percentage of detection is 90 percent. Measurements are performed
          with no data traffic.




© CTC advanced GmbH                                                                               Page 10 of 21


              Test report no.: 1-8662/19-02-12




9.2.3 Radar Test Waveforms
This section provides the parameters for required test waveforms, minimum percentage of successful
detections, and the minimum number of trials that must be used for determining DFS conformance.

Short Pulse Radar Test Waveforms

 Radar Type        Pulse Width       PRI (µsec)             Number of    Minimum            Minimum
                   (µsec)                                   Pulses       Percentage of      Number of
                                                                         Successful         Trials
                                                                         Detection
        0                 1                  1428              18          See Note 1         See Note 1
        1                 1          Test A: 15 unique       Roundup          60%                 30
                                          PRI values
                                     randomly selected
                                      from the list of 23
                                         PRI values in
                                           Table 5a
                                          Test B: 15
                                          unique PRI
                                       values randomly
                                        selected within
                                      the range of 518-
                                       3066 μsec, with
                                          a minimum
                                        increment of 1
                                       μsec, excluding
                                          PRI values
                                       selected in Test
                                               A
        2                 1-5              150-230            23-29            60%                 30
        3                6-10              200-500            16-18            60%                 30
        4                11-20             200-500            12-16            60%                 30
 Aggregate (Radar Types 1-4)                                                   80%                120
 Note 1: Short Pulse Radar Type 0 should be used for the detection bandwidth test, channel move time, and
 channel closing time tests.

A minimum of 30 unique waveforms are required for each of the Short Pulse Radar Types 2 through 4.




 © CTC advanced GmbH                                                                            Page 11 of 21


             Test report no.: 1-8662/19-02-12




Pulse Repetition Intervals Values for Test A

   Pulse Repetition Frequency         Pulse Repetition Frequency          Pulse Repetition Interval
   Number                             (Pulses Per Second)                 (Microseconds)
                1                                 1930.5                               518
                2                                 1858.7                               538
                3                                 1792.1                               558
                4                                 1730.1                               578
                5                                 1672.2                               598
                6                                 1618.1                               618
                7                                 1567.4                               638
                8                                 1519.8                               658
                9                                 1474.9                               678
               10                                 1432.7                               698
               11                                 1392.8                               718
               12                                  1355                                738
               13                                 1319.3                               758
               14                                 1285.3                               778
               15                                 1253.1                               798
               16                                 1222.5                               818
               17                                 1193.3                               838
               18                                 1165.6                               858
               19                                  1139                                878
               20                                 1113.6                               898
               21                                 1089.3                               918
               22                                 1066.1                               938
               23                                 326.2                               3066


Long Pulse Radar Test Waveform

 Radar     Pulse       Chirp Width      PRI     Number of     Number           Minimum           Minimum
 Type      Width         (MHz)        (µsec)    Pulses per      of           Percentage of       Number
           (µsec)                                 Burst       Bursts          Successful         of Trails
                                                                               Detection
   5       50-100         5-20        1000-         1-3         8-20             80%                  30
                                      2000

The parameters for this waveform are randomly chosen. Thirty unique waveforms are required for the Long
Pulse Radar Type waveforms.




 © CTC advanced GmbH                                                                            Page 12 of 21


             Test report no.: 1-8662/19-02-12




Frequency Hopping Radar Test Waveform

 Radar     Pulse         Chirp       Pulses      Hopping      Hopping           Minimum            Minimum
 Type      Width         Width       per Hop    Rate (kHz)    Sequence        Percentage of        Number
           (µsec)        (MHz)                                 Length          Successful          of Trails
                                                               (msec)           Detection
   6          1           333           9          0.333         300              70%                 30

For the Frequency Hopping Radar Type, the same Burst parameters are used for each waveform. The hopping
sequence is different for each waveform and a 100-length segment is selected from the hopping sequence
defined.
The first frequency in a hopping sequence is selected randomly from the group of 475 integer frequencies from
5250 – 5724 MHz. Next, the frequency that was just chosen is removed from the group and a frequency is
randomly selected from the remaining 474 frequencies in the group. This process continues until all 475
frequencies are chosen for the set.




 © CTC advanced GmbH                                                                             Page 13 of 21


             Test report no.: 1-8662/19-02-12




9.3   Test preparation

9.3.1 Channel loading
Timing plots are required with calculations demonstrating a minimum channel loading of approximately 17% or
greater. For example, channel loading can be estimated by setting the spectrum analyzer for zero span and
approximate the Time On/ (Time On + Off Time). This can be done with any appropriate channel BW and
modulation type.

HT40-Mode: Duty Cycle nHT40-mode: 19%
                                                                               RBW    10    MHz
                                                                              * VBW   10    MHz
                        Ref   -8   dBm                 * Att   20   dB         SWT    100    ms


                        -10

                                                                                                  A
                                                                                                  SGL
                        -15
                 1 PK
                 MAXH

                        -20



                        -25



                        -30
                                   TH    -31.2   dBm


                        -35

                                                                                                  3DB

                        -40



                        -45



                        -50



                        -55



                        -60

                        Center     5.51   GHz                            10   ms/




                 Date: 1.FEB.2018                19:34:05


                                                                              Plot 1




 © CTC advanced GmbH                                                                                    Page 14 of 21


             Test report no.: 1-8662/19-02-12




9.3.2 Radar burst timing signal
To accurately determine the channel closing time and channel closing transmission time the spectrum analyser
is triggered at the end of the radar burst (see marker at t = 0ms).

                                                Example plot




                                                   Plot 2




 © CTC advanced GmbH                                                                             Page 15 of 21


               Test report no.: 1-8662/19-02-12




9.4     Test results (prior to use of a channel)
Not applicable.

9.5     Test results (during normal operation)

9.5.1 Channel move time / channel closing transmission time
After a radar’s presence is detected, all transmissions shall cease on the operating channel within 10 seconds.
Transmissions during this period shall consist of normal traffic for a maximum of 200 ms after detection of the
radar signal. In addition, intermittent management and control signals can be sent during the remaining time to
facilitate vacating the operating channel not exceeding 60ms.

The test is performed during normal operation with the highest bandwidth supported by the DUT.

Channel Closing Time
                                                                                RBW    3    MHz   Marker    2    [T1   ]
                                                                               * VBW   3    MHz                   -32.07   dBm
                           Ref   0   dBm               * Att   10   dB          SWT    15    s             114.375000      ms

                           0                                                                      Marker    1    [T1   ]
                                                                                                                  -60.10   dBm
                                                                                                                0.000000   s     A

                           -10
                  1 PK *
                  CLRWR                                                                                                          TRG




                           -20




                           -30       2




                           -40                                                                                                   3DB




                           -50




                                     1
                           -60




                           -70

                           Center    5.51   GHz                          1.5    s/




                  Date: 1.FEB.2018                19:36:18


                                                                               Plot 3

Note:    With Marker 1 at the end of the radar pulse (t = 0ms) the Channel Closing Time is determined by setting
         a Delta-Marker to the point where the last transmission occurred.
         The Channel Closing Time is 114ms




 © CTC advanced GmbH                                                                                                                   Page 16 of 21


             Test report no.: 1-8662/19-02-12




Channel Closing Transmission Time

                                                                               RBW    3   MHz   Marker    1    [T1   ]
                                                                              * VBW   3   MHz                   -61.83   dBm
                          Ref   0   dBm               * Att   10   dB          SWT    1.2   s                 0.000000   s

                          0                                                                     Marker    2    [T1   ]
                                                                                                                -34.45   dBm
                                                                                                         156.750000      ms    A

                          -10
                 1 PK *
                 CLRWR                                                                                                         TRG




                          -20




                          -30
                                                 2




                          -40                                                                                                  3DB




                          -50




                          -60       1




                          -70

                          Center    5.51   GHz                          120   ms/




                 Date: 1.FEB.2018                19:43:13


                                                                              Plot 4



Note:   The accumulated transmission time is calculated by the number of bins occurring after t = 0ms
        multiplied with the Time-per-sweep point-factor resulting from the Sweep Time and number of Sweep
        Points of the Spectrum Analyser.
        The total Channel Closing Transmission Time is 37.2ms.




 © CTC advanced GmbH                                                                                                                 Page 17 of 21


              Test report no.: 1-8662/19-02-12




9.5.2 Non-Occupancy Period
A channel that has been flagged as containing a radar system, either by a channel availability check or in-
service monitoring, is subject to a non-occupancy period of at least 30 minutes. The non occupancy period
starts at the time when the radar system is detected.

                                                                                   RBW    3   MHz       Marker   1    [T1   ]
                                                                                  * VBW   3   MHz                      -58.38   dBm
                          Ref       0   dBm               * Att   10   dB          SWT    1820      s                0.000000   s

                              0


                                                                                                                                      A

                              -10
                 1 PK *
                 CLRWR                                                                                                                TRG




                              -20




                              -30




                              -40                                                                                                     3DB




                              -50



                          1

                              -60




                              -70

                          Center        5.51   GHz                          182    s/




                 Date: 1.FEB.2018                    20:22:04


                                                                                  Plot 5




 © CTC advanced GmbH                                                                                                                        Page 18 of 21


              Test report no.: 1-8662/19-02-12




10    Observations
No observations except those reported with the single test cases have been made.



Annex A           Glossary

           EUT    Equipment under test
          DUT     Device under test
          UUT     Unit under test
          GUE     GNSS User Equipment
          FCC     Federal Communications Commission
        FCC ID    Company Identifier at FCC
             IC   Industry Canada
          PMN     Product marketing name
          HMN     Host marketing name
          HVIN    Hardware version identification number
          FVIN    Firmware version identification number
          EMC     Electromagnetic Compatibility
            HW    Hardware
            SW    Software
       Inv. No.   Inventory number
     S/N or SN    Serial number
              C   Compliant
            NC    Not compliant
            NA    Not applicable
            NP    Not performed
            PP    Positive peak
            QP    Quasi peak
          AVG     Average
            OC    Operating channel
          OCW     Operating channel bandwidth
          OBW     Occupied bandwidth
          OOB     Out of band
           DFS    Dynamic frequency selection
          CAC     Channel availability check
            OP    Occupancy period
          NOP     Non occupancy period
            DC    Duty cycle
          PER     Packet error rate
            CW    Clean wave
            MC    Modulated carrier
         WLAN     Wireless local area network
         RLAN     Radio local area network
         DSSS     Dynamic sequence spread spectrum
         OFDM     Orthogonal frequency division multiplexing



 © CTC advanced GmbH                                                               Page 19 of 21


             Test report no.: 1-8662/19-02-12




Annex B        Document history

  Version                                Applied changes                                 Date of release

     -/-                                   Initial release                                 2019-08-07




Annex C        Accreditation Certificate – D-PL-12076-01-04

                       first page                                          last page




Note: The current certificate annex is published on the website (link see below) of the Accreditation
Body DAkkS or may be received by CTC advanced GmbH on request

https://www.dakks.de/as/ast/d/D-PL-12076-01-04.pdf




 © CTC advanced GmbH                                                                          Page 20 of 21


             Test report no.: 1-8662/19-02-12




Annex D        Accreditation Certificate – D-PL-12076-01-05

                       first page                                          last page




Note: The current certificate annex is published on the website (link see below) of the Accreditation
Body DAkkS or may be received by CTC advanced GmbH on request

https://www.dakks.de/as/ast/d/D-PL-12076-01-05.pdf




################################## END OF TEST REPORT ##################################




 © CTC advanced GmbH                                                                          Page 21 of 21



Document Created: 2019-08-07 09:29:06
Document Modified: 2019-08-07 09:29:06

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC