Test Report RFID

FCC ID: XKB-AXICLWBT

Test Report

Download: PDF
FCCID_4223732

                                                          TEST REPORT
                                                Test report no.: 1-6927/18-01-24

                  Testing laboratory                                                               Applicant
 CTC advanced GmbH                                                              Ingenico Group
 Untertuerkheimer Strasse 6 – 10                                                9 Avenue de la Gare Rovaltain
 66117 Saarbruecken / Germany                                                   26958 Valence Cedex 9 / FRANCE
 Phone:    + 49 681 5 98 - 0                                                    Phone:   -/-
 Fax:      + 49 681 5 98 - 9075                                                 Contact: Nicolas Jacquemont
 Internet: http://www.ctcadvanced.com                                           e-mail:  nicolas.jacquemont@ingenico.com
 e-mail:   mail@ctcadvanced.com                                                 Phone:   +33 4 75 84 21 23

 Accredited Testing Laboratory:
 The testing laboratory (area of testing) is accredited
 according to DIN EN ISO/IEC 17025 (2005) by the
 Deutsche Akkreditierungsstelle GmbH (DAkkS)                                                     Manufacturer
 The accreditation is valid for the scope of testing                            Ingenico Group
 procedures as stated in the accreditation certificate with                     9 Avenue de la Gare Rovaltain
 the registration number: D-PL-12076-01                                         26958 Valence Cedex 9 / FRANCE


                                                               Test standard/s
 FCC - Title 47 CFR            FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part 15 - Radio
 Part 15                       frequency devices
                               Spectrum Management and Telecommunications Radio Standards Specification -
 RSS - 210 Issue 9
                               Licence-Exempt Radio Apparatus: Category I Equipment
                               Spectrum Management and Telecommunications Radio Standards Specification -
 RSS - Gen Issue 5
                               General Requirements for Compliance of Radio Apparatus
 For further applied test standards please refer to section 3 of this test report.


                                                                         Test Item
 Kind of test item:           Payment terminal
 Model name:                  AXIUM D7 CL/WIFI/BT
 FCC ID:                      XKB-AXICLWBT
 IC:                          2586D-AXICLWBT
 Frequency:                   13.56 MHz
 Technology tested:           RFID
 Antenna:                     Integrated loop antenna
                              3.7 V DC by Li-polymer battery
 Power supply:
                              115 V AC by mains adapter
 Temperature range:           0°C to +50°C

This test report is electronically signed and valid without handwritten signature. For verification of the electronic signatures,
the public keys can be requested at the testing laboratory.

 Test report authorized:                                                      Test performed:
                               cn=Andreas Luckenbill, o=CTC advanced                                    cn=Marco Bertolino, o=CTC advanced GmbH,
                               GmbH, ou=LUC-180217,                                                     ou=BTL-161128,
                               email=andreas.luckenbill@ctcadvanced.co                                  email=Marco.Bertolino@ctcadvanced.com,
                               m, c=DE                                                                  c=DE
                               2019.03.05 14:32:08 +01'00'                                              2019.02.28 15:49:53 +01'00'

 Andreas Luckenbill                                                           Marco Bertolino
 Lab Manager                                                                  Lab Manager
 Radio Communications & EMC                                                   Radio Communications & EMC


                   Test report no.: 1-6927/18-01-24




1      Table of contents

1    Table of contents ............................................................................................................................................2
2    General information .......................................................................................................................................3
     2.1       Notes and disclaimer ..........................................................................................................................3
     2.2       Application details ...............................................................................................................................3
     2.3       Test laboratories sub-contracted ......................................................................................................3
3    Test standard/s and references ....................................................................................................................4
4    Test environment............................................................................................................................................5
5    Test item ..........................................................................................................................................................5
     5.1       General description .............................................................................................................................5
     5.2       Additional information ........................................................................................................................5
6    Description of the test setup .........................................................................................................................6
     6.1       Shielded semi anechoic chamber ......................................................................................................7
     6.2       Shielded fully anechoic chamber ......................................................................................................8
     6.3       AC conducted ......................................................................................................................................9
     6.4       Conducted measurements normal and extreme conditions.........................................................10
7    Sequence of testing .....................................................................................................................................11
     7.1       Sequence of testing radiated spurious 9 kHz to 30 MHz...............................................................11
     7.2       Sequence of testing radiated spurious 30 MHz to 1 GHz ..............................................................12
8    Measurement uncertainty ............................................................................................................................13
9    Summary of measurement results .............................................................................................................14
10      Additional comments ...............................................................................................................................14
11      Measurement results ................................................................................................................................15
     11.1         Occupied bandwidth......................................................................................................................15
     11.2         Field strength of the fundamental ................................................................................................17
     11.3         Field strength of the harmonics and spurious ...........................................................................18
     11.4         Conducted limits ............................................................................................................................21
     11.5         Frequency error .............................................................................................................................24
12      Observations .............................................................................................................................................25
Annex A           Glossary ..........................................................................................................................................26
Annex B           Document history ..........................................................................................................................27
Annex C           Accreditation Certificate – D-PL-12076-01-04 .............................................................................27
Annex D           Accreditation Certificate – D-PL-12076-01-05 .............................................................................28




© CTC advanced GmbH                                                                                                                                     Page 2 of 28


              Test report no.: 1-6927/18-01-24




2      General information

2.1    Notes and disclaimer
The test results of this test report relate exclusively to the test item specified in this test report. CTC advanced
GmbH does not assume responsibility for any conclusions and generalizations drawn from the test results with
regard to other specimens or samples of the type of the equipment represented by the test item.
The test report may only be reproduced or published in full. Reproduction or publication of extracts from the report
requires the prior written approval of CTC advanced GmbH.
The testing service provided by CTC advanced GmbH has been rendered under the current "General Terms and
Conditions for CTC advanced GmbH".
CTC advanced GmbH will not be liable for any loss or damage resulting from false, inaccurate, inappropriate or
incomplete product information provided by the customer.
Under no circumstances does the CTC advanced GmbH test report include any endorsement or warranty
regarding the functionality, quality or performance of any other product or service provided.
Under no circumstances does the CTC advanced GmbH test report include or imply any product or service
warranties from CTC advanced GmbH, including, without limitation, any implied warranties of merchantability,
fitness for purpose, or non-infringement, all of which are expressly disclaimed by CTC advanced GmbH.
All rights and remedies regarding vendor’s products and services for which CTC advanced GmbH has prepared
this test report shall be provided by the party offering such products or services and not by CTC advanced GmbH.
In no case this test report can be considered as a Letter of Approval.

This test report is electronically signed and valid without handwritten signature. For verification of the electronic
signatures, the public keys can be requested at the testing laboratory.



2.2    Application details
Date of receipt of order:                2018-09-21
Date of receipt of test item:            2018-10-22
Start of test:                           2018-10-24
End of test:                             2018-10-26
Person(s) present during the test:       -/-



2.3    Test laboratories sub-contracted
None




 © CTC advanced GmbH                                                                                    Page 3 of 28


            Test report no.: 1-6927/18-01-24




3    Test standard/s and references
Test standard                Date       Description
                                        FCC - Title 47 of the Code of Federal Regulations; Chapter I; Part
FCC - Title 47 CFR Part 15   -/-
                                        15 - Radio frequency devices
                                        Spectrum Management and Telecommunications Radio Standards
                             August
RSS - 210 Issue 9                       Specification - Licence-Exempt Radio Apparatus: Category I
                             2016
                                        Equipment
                                        Spectrum Management and Telecommunications Radio Standards
                             April
RSS - Gen Issue 5                       Specification - General Requirements for Compliance of Radio
                             2018
                                        Apparatus



Guidance                     Version    Description

                                        American national standard for methods of measurement of radio-
ANSI C63.4-2014              -/-        noise emissions from low-voltage electrical and electronic
                                        equipment in the range of 9 kHz to 40 GHz
                                        American national standard of procedures for compliance testing
ANSI C63.10-2013             -/-
                                        of unlicensed wireless devices




© CTC advanced GmbH                                                                             Page 4 of 28


              Test report no.: 1-6927/18-01-24




4     Test environment
                                   Tnom    +24 °C during room temperature tests
Temperature                  :     Tmax    +50 °C during high temperature tests
                                   Tmin      0 °C during low temperature tests
Relative humidity content    :             42 %
Barometric pressure          :             1026 hpa
                                   Vnom    3.7 V DC by Li-polymer battery
                                           115 V AC by mains adapter
Power supply                 :
                                   Vmax    4.2 V
                                   Vmin    3.5 V



5     Test item

5.1   General description

Kind of test item            :   Payment terminal
Type identification          :   AXIUM D7 CL/WIFI/BT
HMN                          :   -/-
PMN                          :   Axium D7
HVIN                         :   AXIUM D7 CL/WIFI/BT
FVIN                         :   4.19.1
S/N serial number            :   Radiated unit: 182607314201129703156279
Hardware status              :   296230079
Software status              :   4.19.1
Firmware status              :   -/-
Frequency                    :   13.56 MHz
Type of radio transmission   :
                                 modulated carrier, clean carrier
Use of frequency spectrum    :
Type of modulation           :   ASK
Number of channels           :   1
Antenna                      :   Integrated loop antenna
                                 3.7 V DC by Li-polymer battery
Power supply                 :
                                 115 V AC by mains adapter
Temperature range            :   0°C to +50°C



5.2   Additional information
The content of the following annexes is defined in the QA. It may be that not all of the listed annexes are
necessary for this report, thus some values in between may be missing.

Test setup and EUT photos are included in test report:          1-6927/18-01-23_AnnexA
                                                                1-6927/18-01-23_AnnexB
                                                                1-6927/18-01-23_AnnexE




 © CTC advanced GmbH                                                                                   Page 5 of 28


                   Test report no.: 1-6927/18-01-24




6           Description of the test setup
Typically, the calibrations of the test apparatus are commissioned to and performed by an accredited calibration
laboratory. The calibration intervals are determined in accordance with the DIN EN ISO/IEC 17025. In addition to
the external calibrations, the laboratory executes comparison measurements with other calibrated test systems
or effective verifications. Weekly chamber inspections and range calibrations are performed. Where possible, RF
generating and signaling equipment as well as measuring receivers and analyzers are connected to an external
high-precision 10 MHz reference (GPS-based or rubidium frequency standard).

In order to simplify the identification of the equipment used at some special tests, some items of test equipment
and ancillaries can be provided with an identifier or number in the equipment list below (Lab/Item).



Agenda: Kind of Calibration

    k        calibration / calibrated                     EK    limited calibration
    ne       not required (k, ev, izw, zw not required)   zw    cyclical maintenance (external cyclical
                                                                maintenance)
    ev       periodic self verification                   izw   internal cyclical maintenance
    Ve       long-term stability recognized               g     blocked for accredited testing
    vlkI!    Attention: extended calibration interval
    NK!      Attention: not calibrated                    *)    next calibration ordered / currently in progress




 © CTC advanced GmbH                                                                                      Page 6 of 28


               Test report no.: 1-6927/18-01-24




6.1    Shielded semi anechoic chamber
The radiated measurements are performed in vertical and horizontal plane in the frequency range from 30 MHz
to 1 GHz in semi-anechoic chambers. The EUT is positioned on a non-conductive support with a height of 0.80
m above a conductive ground plane that covers the whole chamber. The receiving antennas are conform to
specifications ANSI C63. These antennas can be moved over the height range between 1.0 m and 4.0 m in order
to search for maximum field strength emitted from EUT. The measurement distances between EUT and receiving
antennas are indicated in the test setups for the various frequency ranges. For each measurement, the EUT is
rotated in all three axes until the maximum field strength is received. The wanted and unwanted emissions are
received by spectrum analyzers where the detector modes and resolution bandwidths over various frequency
ranges are set according to requirement ANSI C63.




Measurement distance: tri-log antenna 10 meter
EMC32 software version: 10.30.0

FS = UR + CL + AF
(FS-field strength; UR-voltage at the receiver; CL-loss of the cable; AF-antenna factor)

Example calculation:
FS [dBµV/m] = 12.35 [dBµV/m] + 1.90 [dB] + 16.80 [dB/m] = 31.05 [dBµV/m] (35.69 µV/m)

Equipment table:

       Lab /                                                                                          Kind of       Last        Next
 No.               Equipment               Type            Manufacturer       Serial No.    INV. No.
       Item                                                                                          Calibration Calibration Calibration
 1       A         Switch-Unit            3488A                HP             2719A14505   300000368     ev          -/-         -/-
 2       A         Meßkabine 1        HF-Absorberhalle    MWB AG 300023                    300000551     ne          -/-         -/-
 3       A      EMI Test Receiver         ESCI 3              R&S               100083     300003312      k      15.12.2017 14.12.2018
               Analyzer-Reference-
                                                                              A3509 07/0
 4       A     System (Harmonics         ARS 16/1               SPS                        300003314     vlKI!    15.01.2018   14.01.2020
                                                                                0205
                   and Flicker)
 5       A        Antenna Tower         Model 2175         ETS-Lindgren         64762      300003745      izw         -/-          -/-
                    Positioning
 6       A                              Model 2090         ETS-Lindgren         64672      300003746      izw         -/-          -/-
                    Controller
               Turntable Interface-
 7       A                             Model 105637        ETS-Lindgren         44583      300003747      izw         -/-          -/-
                       Box
               TRILOG Broadband
                                                         Schwarzbeck Mess -
 8       A       Test-Antenna 30         VULB9163                                371       300003854     vlKI!    24.11.2017   23.11.2020
                                                             Elektronik
                   MHz - 3 GHz


 © CTC advanced GmbH                                                                                                        Page 7 of 28


                Test report no.: 1-6927/18-01-24




6.2     Shielded fully anechoic chamber




Measurement distance: loop antenna 3 meter

FS = UR + CA + AF
(FS-field strength; UR-voltage at the receiver; CA-loss of the signal path; AF-antenna factor)

Example calculation:
FS [dBµV/m] = 40.0 [dBµV/m] + (-35.8) [dB] + 32.9 [dB/m] = 37.1 [dBµV/m] (71.61 µV/m)


Equipment table:

        Lab /                                                                                          Kind of       Last        Next
  No.               Equipment             Type          Manufacturer         Serial No.    INV. No.
        Item                                                                                          Calibration Calibration Calibration
                Active Loop Antenna
 1       A                                6502             EMCO                2210       300001015      vlKI!    07.07.2017   06.07.2019
                  9 kHz to 30 MHz
 2       A       Anechoic chamber       FAC 3/5m         MWB / TDK           87400/02     300000996       ev          -/-          -/-
 3       A      Switch / Control Unit    3488A             HP                   *         300000199       ne          -/-          -/-
                 EMI Test Receiver
 4       A                               ESU26              R&S               100037      300003555       k       20.12.2017   19.12.2018
                  20Hz- 26,5GHz
                   4U RF Switch
 5       A                               L4491A      Agilent Technologies   MY50000037    300004509       ne          -/-          -/-
                      Platform
                    NEXIO EMV-          BAT EMC
 6       A                                                 EMCO                 -/-       300004682       ne          -/-          -/-
                      Software          V3.16.0.49
 7       A               PC              ExOne              F+W                 -/-       300004703       ne          -/-          -/-




 © CTC advanced GmbH                                                                                                        Page 8 of 28


                Test report no.: 1-6927/18-01-24




6.3     AC conducted




FS = UR + CF + VC
(FS-field strength; UR-voltage at the receiver; CR-loss of the cable and filter; VC-correction factor of the ISN)

Example calculation:
FS [dBµV/m] = 37.62 [dBµV/m] + 9.90 [dB] + 0.23 [dB] = 47.75 [dBµV/m] (244.06 µV/m)


Equipment table:

        Lab /                                                                                        Kind of       Last        Next
  No.               Equipment           Type          Manufacturer         Serial No.    INV. No.
        Item                                                                                        Calibration Calibration Calibration
                Two-line V-Network
 1       A       (LISN) 9 kHz to 30    ESH3-Z5            R&S             893045/004    300000584       k       13.12.2017   12.12.2018
                        MHz
 2       A        RF-Filter-section     85420E             HP             3427A00162    300002214      NK!          -/-          -/-
                        AC-
 3       A        Spannungsquelle     MV2616-V          EM-Test             0397-12     300003259      vlKI!    18.12.2017   17.12.2019
                      variabel
                Analyzer-Reference-
                                                                          A3509 07/0
 4       A      System (Harmonics      ARS 16/1           SPS                           300003314      vlKI!    15.01.2018   14.01.2020
                                                                            0205
                    and Flicker)
 5       A       Hochpass 150 kHz       EZ-25            R&S                100010      300003798       ev          -/-          -/-
 6       A        Power Supply DC     NGSM 32/10    Rohde & Schwarz          3939       400000192      vlKI!    31.01.2017   30.01.2020
                 MXE EMI Receiver
 7       A                             N9038A      Agilent Technologies   MY51210197    300004405       k       18.12.2017   17.12.2018
                 20 Hz to 26,5 GHz




 © CTC advanced GmbH                                                                                                      Page 9 of 28


               Test report no.: 1-6927/18-01-24




6.4    Conducted measurements normal and extreme conditions




OP = AV + CA
(OP-output power; AV-analyzer value; CA-loss signal path)

Example calculation:
OP [dBm] = 6.0 [dBm] + 11.7 [dB] = 17.7 [dBm] (58.88 mW)


Equipment table:

       Lab /                                                                                      Kind of       Last        Next
 No.              Equipment              Type          Manufacturer     Serial No.    INV. No.
       Item                                                                                      Calibration Calibration Calibration
               Temperature Test
 1       B                              VT 4002       Heraeus Voetsch   521/83761    300002326       ev      07.05.2018    06.05.2020
                   Chamber
               Signal Analyzer 40
 2      A, B                             FSV40             R&S           101042      300004517       k       16.01.2018    15.01.2019
                      GHz
                                    ST18/SMAm/SMAm/                     Batch no.
 3      A, B       RF-Cable                           Huber & Suhner                 400001184       ev          -/-           -/-
                                           72                            699714
                Synchron Power
 4      A, B                             SPM-4             CTC              1        300005580       ev          -/-           -/-
                    Meter
                                                         Weinschel
 5      A, B      DC-Blocker            WA7046                             -/-       400001310       ev          -/-           -/-
                                                         Associates
 6      A, B   DC Power Supply         HMP2020        Rohde & Schwarz    102850      300005517      vlKI!    14.12.2017    13.12.2019




 © CTC advanced GmbH                                                                                                   Page 10 of 28


              Test report no.: 1-6927/18-01-24




7     Sequence of testing

7.1   Sequence of testing radiated spurious 9 kHz to 30 MHz
Setup
   • The equipment is set up to simulate normal operation mode as described in the user manual or defined
      by the manufacturer.
   • If the EUT is a tabletop system, it is placed on a table with 0.8 m height.
   • If the EUT is a floor standing device, it is placed directly on the turn table.
   • Auxiliary equipment and cables are positioned to simulate normal operation conditions as described in
      ANSI C 63.4.
   • The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
   • Measurement distance is 3 m (see ANSI C 63.4) – see test details.
   • EUT is set into operation.

Premeasurement*
   • The turntable rotates from 0° to 315° using 45° steps.
   • The antenna height is 1 m.
   • At each turntable position the analyzer sweeps with positive-peak detector to find the maximum of all
      emissions.

Final measurement
    • Identified emissions during the pre-measurement are maximized by the software by rotating the turntable
       from 0° to 360°.
    • Loop antenna is rotated about its vertical axis for maximum response at each azimuth about the EUT.
       (For certain applications, the loop antenna plane may also need to be positioned horizontally at the
       specified distance from the EUT)
    • The final measurement is done in the position (turntable and elevation) causing the highest emissions
       with quasi-peak (as described in ANSI C 63.4).
    • Final levels, frequency, measuring time, bandwidth, turntable position, correction factor, margin to the
       limit and limit will be recorded. A plot with the graph of the premeasurement and the limit is stored.

*)Note: The sequence will be repeated three times with different EUT orientations.




 © CTC advanced GmbH                                                                             Page 11 of 28


              Test report no.: 1-6927/18-01-24




7.2   Sequence of testing radiated spurious 30 MHz to 1 GHz
Setup
   • The equipment is set up to simulate normal operation mode as described in the user manual or defined
      by the manufacturer.
   • If the EUT is a tabletop system, a table with 0.8 m height is used, which is placed on the ground plane.
   • If the EUT is a floor standing device, it is placed on the ground plane with insulation between both.
   • Auxiliary equipment and cables are positioned to simulate normal operation conditions as described in
      ANSI C 63.4.
   • The AC power port of the EUT (if available) is connected to a power outlet below the turntable.
   • Measurement distance is 10 m or 3 m (see ANSI C 63.4) – see test details.
   • EUT is set into operation.

Premeasurement
   • The turntable rotates from 0° to 315° using 45° steps.
   • The antenna is polarized vertical and horizontal.
   • The antenna height changes from 1 m to 3 m.
   • At each turntable position, antenna polarization and height the analyzer sweeps three times in peak to
      find the maximum of all emissions.

Final measurement
    • The final measurement is performed for at least six highest peaks according to the requirements of the
       ANSI C63.4.
    • Based on antenna and turntable positions at which the peak values are measured the software maximize
       the peaks by changing turntable position ± 45° and antenna height between 1 and 4 m.
    • The final measurement is done with quasi-peak detector (as described in ANSI C 63.4).
    • Final levels, frequency, measuring time, bandwidth, antenna height, antenna polarization, turntable angle,
       correction factor, margin to the limit and limit are recorded. A plot with the graph of the premeasurement
       with marked maximum final results and the limit is stored.




 © CTC advanced GmbH                                                                                Page 12 of 28


            Test report no.: 1-6927/18-01-24




8    Measurement uncertainty

                                       Measurement uncertainty
                          Test case                                      Uncertainty
Occupied bandwidth                                          ± used RBW
Field strength of the fundamental                           ± 3 dB
Field strength of the harmonics and spurious                ± 3 dB
Receiver spurious emissions and cabinet radiations          ± 3 dB
Conducted limits                                            ± 2.6 dB




© CTC advanced GmbH                                                                    Page 13 of 28


                   Test report no.: 1-6927/18-01-24




9        Summary of measurement results

         ☒            No deviations from the technical specifications were ascertained
         ☐            There were deviations from the technical specifications ascertained

         ☐
                      This test report is only a partial test report. The content and verdict of the performed test cases
                      are listed below.

    TC Identifier                     Description                       Verdict           Date               Remark
                                      CFR Part 15
    RF-Testing                      RSS 210 Issue 9                    See table!     2019-02-28               -/-
                                    RSS Gen Issue 5

         Test
                                                 Temperature Power source
    specification             Test case                                              C     NC     NA    NP     Remark
                                                  conditions  conditions
       clause
                                                                                     ☒      ☐     ☐     ☐
      RSS Gen
                         Occupied bandwidth        Nominal           Nominal                                         -/-
       Issue 5

                                                                                     ☒      ☐     ☐     ☐
  § 15.225 (a)           Field strength of the
                                                   Nominal           Nominal                                         -/-
 RSS 210 Issue 9             fundamental

       § 15.209          Field strength of the
          &                 harmonics and          Nominal           Nominal         ☒      ☐     ☐     ☐            -/-
    § 15.225 (b-d)             spurious

                          Receiver spurious
        § 15.109           emissions and           Nominal           Nominal         ☐      ☐     ☒     ☐            -/-
                          cabinet radiations

                                                                                     ☒      ☐     ☐     ☐
        §15.107
                           Conducted limits        Nominal           Nominal                                         -/-
        §15.207
                                                  Normal &           Normal &
                                                                                     ☒      ☐     ☐     ☐
  § 15.225 (a)
                        Frequency tolerance        extreme            extreme                                        -/-
 RSS 210 Issue 9
                                                  conditions         conditions


Notes:

    C         Compliant           NC        Not compliant       NA       Not applicable      NP        Not performed




10       Additional comments
Reference documents:                 None

Special test descriptions:           None

Configuration descriptions:          None




 © CTC advanced GmbH                                                                                         Page 14 of 28


              Test report no.: 1-6927/18-01-24




11       Measurement results

11.1 Occupied bandwidth
Measurement:

The emission bandwidth (x dB) is defined as the frequency range between two points, one above and one
below the carrier frequency, at which the spectral density of the emission is attenuated x dB below the
maximum in-band spectral density of the modulated signal.

                                         Measurement parameters
 Detector:                                            Peak
 Resolution bandwidth:                                1 % – 5 % of the occupied bandwidth
 Video bandwidth:                                     ≥ 3x RBW
 Trace mode:                                          Max hold
 Analyser function:                                   99 % power function
 Used equipment:                                      See chapter 6.4 A
 Measurement uncertainty:                             See chapter 8



Limit:

                                                     IC
                                   for RSP-100 test report coversheet only



Result:

                                         99% emission bandwidth
                                                647 kHz




 © CTC advanced GmbH                                                                             Page 15 of 28


             Test report no.: 1-6927/18-01-24




Plot:

Plot 1: 99 % emission bandwidth




                Date: 6.NOV.2018   07:58:24




 © CTC advanced GmbH                            Page 16 of 28


              Test report no.: 1-6927/18-01-24




11.2 Field strength of the fundamental
Measurement:

The maximum detected field strength for the carrier signal.

                                                  Measurement parameters
 Detector:                                                     Quasi peak / peak (worst case)
 Resolution bandwidth:                                         120 kHz
 Video bandwidth:                                              ≥ 3x RBW
 Trace mode:                                                   Max hold
 Used equipment:                                               See chapter 6.2 A
 Measurement uncertainty:                                      See chapter 8



Limit:

                                                              FCC & IC
             Frequency                                      Field strength                                                           Measurement distance
               (MHz)                                            (µV/m)                                                                      (m)
          13.553 to 13.567                               15,848 (84 dBµV/m)                                                                  30



Recalculation:

                                                  According to ANSI C63.10
          Frequency                                       Formula                                                                         Correction value
                                                                              𝑑𝑑nearfield                     𝑑𝑑𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙𝑙
                                    FSlimit = FSmax −40 log �                                    � − 20log(                      )
                                                                              𝑑𝑑𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚𝑚            𝑑𝑑𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛𝑛

                                FSlimit        is the calculation of field strength at the limit distance,
          13.56 MHz                            expressed in dBµV/m
                                                                                                                                       -21.4 from 3m to 30m
                                FSmax          is the measured field strength, expressed in dBµV/m
                                dnear field    is the λ/2π distance
                                dmeasure       is the distance of the measurement point from EUT
                                dlimit         is the reference limit distance




Result:

                                              Field strength of the fundamental
 Frequency                                                                13.56 MHz
 Distance                                                   @3m                                                                            @ 30 m
 Measured / calculated value (PP)                        72.5 dBµV/m                                                                     51.1 dBµV/m
 Measured / calculated value (QP)                        66.6 dBµV/m                                                                     45.2 dBµV/m




 © CTC advanced GmbH                                                                                                                                 Page 17 of 28


               Test report no.: 1-6927/18-01-24




11.3 Field strength of the harmonics and spurious
Measurement:

The maximum detected field strength for the harmonics and spurious.

                                          Measurement parameters
                                                       Quasi peak / average or
 Detector:
                                                       peak (worst case – pre-scan)
                                                       F < 150 kHz: 200 Hz
 Resolution bandwidth:                                 150 kHz < F < 30 MHz: 9 kHz
                                                       30 MHz < F < 1 GHz: 120 kHz
                                                       F < 150 kHz: 1 kHz
 Video bandwidth:                                      150 kHz < F < 30 MHz: 100 kHz
                                                       30 MHz < F < 1 GHz: 300 kHz
 Trace mode:                                           Max hold
 Used equipment:                                       See chapter 6.1 A; 6.2 A & 6.4 A
 Measurement uncertainty:                              See chapter 8



Limit:

                                                  FCC & IC
              Frequency                         Field strength                   Measurement distance
                 (MHz)                            (dBµV/m)                              (m)
             0.009 – 0.490                       2400/F(kHz)                            300
             0.490 – 1.705                      24000/F(kHz)                             30
              1.705 – 30                      30 (29.5 dBµV/m)                           30
                30 – 88                        100 (40 dBµV/m)                           3
               88 – 216                       150 (43.5 dBµV/m)                          3
               216 – 960                       200 (46 dBµV/m)                           3

Note:      For a reduced measurement distance, please take a look at the limit line and the ANSI C63.10-2013
           sub clause 6.4 radiated emissions from unlicensed wireless devices below 30 MHz.



Result:

                                            Detected emissions
          Frequency                                     Resolution bandwidth           Detected value
                                   Detector
            (MHz)                                                (kHz)                (dBµV/m @ 3m)
             Between 9 kHz and 30 MHz: All detected emissions are more than 20 dB below the limit.
                          Between 30 MHz and 1 GHz: See the table below the plot.




 © CTC advanced GmbH                                                                              Page 18 of 28


                      Test report no.: 1-6927/18-01-24




Plots:

Plot 1: 9 kHz – 30 MHz, magnetic emissions
         130
dBµV/m
         120


         110


         100


          90


          80


          70


          60


          50


          40


          30


          20


          10
               9kHz                                    100k               1M   10M            30MHz
                                                              Frequency




Plot 2: Spectrum mask




                         Date: 6.NOV.2018   07:53:52




 © CTC advanced GmbH                                                                 Page 19 of 28


                          Test report no.: 1-6927/18-01-24




Plot 3: 30 MHz – 1 GHz, vertical and horizontal polarisation



                                 60

                                 55

                                 50

                                 45                                                                                    FCC_10m_B

                                 40
               Level in dBµV/m




                                 35

                                 30

                                 25

                                 20

                                 15

                                 10

                                 5

                                 0
                                 30M            50   60          80 100M              200        300    400    500         800   1,05G
                                                                               Frequency in Hz



Final_Result

                                                                                  Meas.
    Frequency                         QuasiPeak        Limit          Margin                Bandwidth         Height             Azimuth    Corr.
                                                                                  Time                                 Pol
      (MHz)                           (dBµV/m)       (dBµV/m)          (dB)                   (kHz)            (cm)               (deg)     (dB)
                                                                                  (ms)
      35.167                            14.72             30.0        15.28       1000           120          104.0    V            0.0     13.8
      39.235                            14.41             30.0        15.59       1000           120          102.0    V           90.0     14.3
      40.679                            22.51             30.0         7.49       1000           120          100.0    V           90.0     14.4
      42.099                            16.07             30.0        13.93       1000           120          100.0    V            0.0     14.5
     601.759                            23.50             36.0        12.50       1000           120          101.0    H           90.0     20.4
     810.964                            19.25             36.0        16.75       1000           120          203.0    H          180.0     22.6




 © CTC advanced GmbH                                                                                                                 Page 20 of 28


             Test report no.: 1-6927/18-01-24




11.4 Conducted limits
Measurement:

Measurement of the conducted spurious emissions for an intentional radiator that is designed to be connected
to the public utility (AC) power line.

                                         Measurement parameters
                                                      Quasi peak / average or
 Detector:
                                                      peak (worst case – pre-scan)
                                                      F < 150 kHz:        200 Hz
 Resolution bandwidth:
                                                      F > 150 kHz:        9 kHz
                                                      F < 150 kHz:        1 kHz
 Video bandwidth:
                                                      F > 150 kHz:        100 kHz
 Trace mode:                                          Max hold
 Used equipment:                                      See chapter 6.3 A
 Measurement uncertainty:                             See chapter 8



Limit:

                                                  FCC & IC
             Frequency                           Quasi-peak                             Average
               (MHz)                              (dBµV/m)                             (dBµV/m)
             0.15 – 0.5                            66 to 56*                           56 to 46*
               0.5 – 5                                56                                  46
              5 – 30.0                                60                                  50




 © CTC advanced GmbH                                                                               Page 21 of 28


                                 Test report no.: 1-6927/18-01-24




Plots:

Plot 1: 150 kHz to 30 MHz, phase line


                                                                                                                            Premeasurement
                                                                      Measurement                                           Average limit class B
                                                                                                                            Quasi peak limit class B
                                                                                                                            Average level

                                                                        Phase line                                          Quasi peak level




                                80.0




                                70.0




                                60.0




                                50.0
            Amplitude in dBµV




                                40.0




                                30.0




                                20.0




                                10.0




                                  0
                                  150.0K                       1.0M                                   10.0M                                            30.0M

                                                                      Frequency in Hz




                                                                                              Project ID: 1-6927/18-01-02




                                           Quasi peak     Margin                        Average                    Margin
   Frequency                                                          Limit QP                                                                                 Limit AV
                                             level      quasi peak                       level                     average
      MHz                                    dBµV          dB          dBµV              dBµV                        dB                                         dBµV
    0.151188                                 34.29        31.65        65.934            28.60                      27.36                                       55.966
    1.586802                                 22.40        33.60        56.000            11.99                      34.01                                       46.000
    2.852183                                 25.08        30.92        56.000            16.81                      29.19                                       46.000
    3.300574                                 44.65        11.35        56.000            19.58                      26.42                                       46.000
    3.945127                                 38.94        17.06        56.000            18.47                      27.53                                       46.000
   24.302845                                 31.12        28.88        60.000            19.70                      30.30                                       50.000




 © CTC advanced GmbH                                                                                                                                           Page 22 of 28


                                 Test report no.: 1-6927/18-01-24




Plot 2: 150 kHz to 30 MHz, neutral line


                                                                                                                            Premeasurement
                                                                      Measurement                                           Average limit class B
                                                                                                                            Quasi peak limit class B
                                                                                                                            Average level

                                                                        Neutral line                                        Quasi peak level




                                80.0




                                70.0




                                60.0




                                50.0
            Amplitude in dBµV




                                40.0




                                30.0




                                20.0




                                10.0




                                  0
                                  150.0K                       1.0M                                   10.0M                                            30.0M

                                                                      Frequency in Hz




                                                                                              Project ID: 1-6927/18-01-02




                                           Quasi peak     Margin                        Average                    Margin
   Frequency                                                          Limit QP                                                                                 Limit AV
                                             level      quasi peak                       level                     average
      MHz                                    dBµV          dB          dBµV              dBµV                        dB                                         dBµV
    0.153554                                 34.12        31.68        65.805            28.52                      27.38                                       55.898
    1.278542                                 22.59        33.41        56.000            12.63                      33.37                                       46.000
    3.424901                                 22.00        34.00        56.000            11.07                      34.93                                       46.000
   23.754019                                 23.25        36.75        60.000            12.20                      37.80                                       50.000




 © CTC advanced GmbH                                                                                                                                           Page 23 of 28


              Test report no.: 1-6927/18-01-24




11.5 Frequency error
Measurement:

The maximum detected field strength for the spurious.

                                         Measurement parameters
 Detector:                                            Peak detector
 Resolution bandwidth:                                100 Hz
 Video bandwidth:                                     > RBW
 Trace mode:                                          Max hold
 Used equipment:                                      See chapter 6.4 B
 Measurement uncertainty:                             See chapter 8


Limit:

                                                  FCC & IC
  The frequency tolerance of the carrier signal shall be maintained within +/- 0.01% of the operating
  frequency over a temperature variation of -20 degrees to +50 degrees C at normal supply voltage,
  and for a variation in the primary supply voltage from 85% to 115% of the rated supply voltage at a
                                temperature of 20 degrees C. (±1.356 kHz)

                  Carrier frequency stability shall be maintained to ±0.01% (±100 ppm)


Result: Temperature variation

                                             Frequency tolerance
   Measured frequency           Frequency error
                                                            Conditions                     Result
         (MHz)                       (kHz)
      13.5595950                      -0.4           -20 °C & 100% voltage               compliant
      13.5596090                      -0.4           -10 °C & 100% voltage               compliant
      13.5595660                      -0.4             0 °C & 100% voltage               compliant
      13.5595510                      -0.4           +10 °C & 100% voltage               compliant
      13.5595370                      -0.5           +20 °C & 100% voltage               compliant
      13.5595080                      -0.5           +30 °C & 100% voltage               compliant
      13.5594930                      -0.5           +40 °C & 100% voltage               compliant
      13.5595080                      -0.5           +50 °C & 100% voltage               compliant


Result: Voltage variation

                                             Frequency tolerance
   Measured frequency           Frequency error
                                                            Conditions                     Result
         (MHz)                       (kHz)
      13.5595370                      -0.5           +20 °C & 85%* voltage               compliant
      13.5595370                      -0.5           +20 °C & 100% voltage               compliant
      13.5595370                      -0.5           +20 °C & 115% voltage               compliant

*85% of the nominal voltage = 3.2V. The EUT is switching of below 3.5V. Tests are made with 3.5V DC.




 © CTC advanced GmbH                                                                            Page 24 of 28


              Test report no.: 1-6927/18-01-24




Plots:

Plot 1: Tnom & Vnom




                 Date:31.O CT.2018 14:58:30




12       Observations
No observations except those reported with the single test cases have been made.




 © CTC advanced GmbH                                                               Page 25 of 28


            Test report no.: 1-6927/18-01-24




Annex A         Glossary

         EUT    Equipment under test
        DUT     Device under test
        UUT     Unit under test
        GUE     GNSS User Equipment
        ETSI    European Telecommunications Standards Institute
          EN    European Standard
        FCC     Federal Communications Commission
      FCC ID    Company Identifier at FCC
           IC   Industry Canada
        PMN     Product marketing name
        HMN     Host marketing name
        HVIN    Hardware version identification number
        FVIN    Firmware version identification number
        EMC     Electromagnetic Compatibility
          HW    Hardware
          SW    Software
     Inv. No.   Inventory number
   S/N or SN    Serial number
            C   Compliant
          NC    Not compliant
          NA    Not applicable
          NP    Not performed
          PP    Positive peak
          QP    Quasi peak
        AVG     Average
          OC    Operating channel
        OCW     Operating channel bandwidth
        OBW     Occupied bandwidth
        OOB     Out of band
         DFS    Dynamic frequency selection
        CAC     Channel availability check
          OP    Occupancy period
        NOP     Non occupancy period
          DC    Duty cycle
        PER     Packet error rate
          CW    Clean wave
          MC    Modulated carrier
       WLAN     Wireless local area network
       RLAN     Radio local area network
       DSSS     Dynamic sequence spread spectrum
       OFDM     Orthogonal frequency division multiplexing
       FHSS     Frequency hopping spread spectrum
       GNSS     Global Navigation Satellite System
        C/N0    Carrier to noise-density ratio, expressed in dB-Hz



© CTC advanced GmbH                                                  Page 26 of 28


             Test report no.: 1-6927/18-01-24




Annex B        Document history

  Version                                Applied changes                                 Date of release

     -/-                                   Initial release                                 2019-02-28




Annex C        Accreditation Certificate – D-PL-12076-01-04

                       first page                                          last page




Note: The current certificate annex is published on the website (link see below) of the Accreditation
Body DAkkS or may be received by CTC advanced GmbH on request

https://www.dakks.de/as/ast/d/D-PL-12076-01-04.pdf




 © CTC advanced GmbH                                                                          Page 27 of 28


             Test report no.: 1-6927/18-01-24




Annex D        Accreditation Certificate – D-PL-12076-01-05

                       first page                                          last page




Note: The current certificate annex is published on the website (link see below) of the Accreditation
Body DAkkS or may be received by CTC advanced GmbH on request

https://www.dakks.de/as/ast/d/D-PL-12076-01-05.pdf




################################## END OF TEST REPORT ##################################



 © CTC advanced GmbH                                                                          Page 28 of 28



Document Created: 2019-03-05 14:32:08
Document Modified: 2019-03-05 14:32:08

© 2024 FCC.report