Test Report

FCC ID: XGS-RL76052

Test Report

Download: PDF
FCCID_4332763

RF TEST
REPORT

Report No.: FCC IC_RF_SL19022001-ORB-001
Supersede Report No.: None

 Applicant (FCC)                      :       ORBCOMM Inc.
 Product Name                         :       TripLINK 12LB (CT4000)
 Model No.                            :       TripLINK 12LB
                                              47 CFR 15.247
 Test Standard                            :
                                              RSS 247 Iss 2: Feb 2017
                                              ANSI C63.10: 2013
 Test Method                              :
                                              RSS Gen Iss 5: April 2018
 FCC ID                                   : XGS-RL76052
 Contains FCC IDs                         : BT: XGS-UNNB30 / Cellular: XPY1EHM44NN
 IC                                       : 11881A-RL76052
 Contains IC:                             : BT: 11881A-UNNB30 / Cellular: 8595A-1EHM44NN
 Dates of test                            : 05/20/2019
 Issue Date                               : 05/24/2019
 Test Result                              : ☒ Pass             ☐ Fail
 Equipment complied with the specification         [X]
 Equipment did not comply with the specification [ ]




 This Test Report is Issued Under the Authority of:




                       Gary Chou                                                  Chen Ge
                   Compliance Engineer                                       Engineer Reviewer


                                                  Issued By:
                                             SIEMIC Laboratories
                                  775 Montague Expressway, Milpitas, 95035 CA




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                                     Test report No.      FCC IC_RF_SL19022001-ORB-001
                                                                     Page                 2 of 18




                                         Laboratory Introduction
SIEMIC, headquartered in the heart of Silicon Valley, with superior facilities in US and Asia, is one of the leading independent testing
and certification facilities providing customers with one-stop shop services for Compliance Testing and Global Certifications.




In addition to testing and certification, SIEMIC provides initial design reviews and compliance management throughout a project. Our
  extensive experience with China, Asia Pacific, North America, European, and International compliance requirements, assures the
                         fastest, most cost effective way to attain regulatory compliance for the global markets.

                                   Accreditations for Conformity Assessment
           Country/Region                  Accreditation Body                                        Scope
                 USA                            FCC, A2LA                                 EMC, RF/Wireless, Telecom
              Canada                         IC, A2LA, NIST                               EMC, RF/Wireless, Telecom
               Taiwan                       BSMI, NCC, NIST                                EMC, RF, Telecom, Safety
             Hong Kong                         OFTA, NIST                                     RF/Wireless, Telecom
              Australia                        NATA, NIST                                  EMC, RF, Telecom, Safety
               Korea                         KCC/RRA, NIST                              EMI, EMS, RF, Telecom, Safety
               Japan                     VCCI, JATE, TELEC, RFT                            EMI, RF/Wireless, Telecom
               Mexico                    NOM, COFETEL, Caniety                         Safety, EMC, RF/Wireless, Telecom
              Europe                           A2LA, NIST                                  EMC, RF, Telecom, Safety
                Israel                          MOC, NIST                                  EMC, RF, Telecom, Safety


                                    Accreditations for Product Certifications
               Country                      Accreditation Body                                  Scope
                 USA                          FCC TCB, NIST                               EMC, RF, Telecom
               Canada                          IC FCB, NIST                               EMC, RF, Telecom
              Singapore                          iDA, NIST                                EMC, RF, Telecom
                 EU                                 NB                            EMC & Radio Equipment Directive (RED)
                Japan                         MIC (RCB 208)                                   RF, Telecom
              Hong Kong                       OFTA (US002)                                    RF, Telecom



          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                Visit us at: www.siemic.com; Follow us at:


                                                                                            Test report No.          FCC IC_RF_SL19022001-ORB-001
                                                                                            Page                     3 of 18


CONTENTS
1      REPORT REVISION HISTORY ....................................................................................................................................... 4
2      EXECUTIVE SUMMARY................................................................................................................................................. 5
3      CUSTOMER INFORMATION .......................................................................................................................................... 5
4      TEST SITE INFORMATION ............................................................................................................................................ 5
5      MODIFICATION ............................................................................................................................................................. 5
6      EUT INFORMATION ...................................................................................................................................................... 6
     6.1    EUT Description ........................................................................................................................................................ 6
     6.2    Spec for LoRaWan Radio ........................................................................................................................................... 6
     6.3    EUT test modes/configuration Description.................................................................................................................... 6
7      SUPPORTING EQUIPMENT/SOFTWARE AND CABLING DESCRIPTION......................................................................... 7
     7.1    Supporting Equipment ............................................................................................................................................... 7
     7.2    Cabling Description ................................................................................................................................................... 7
     7.3    Test Software Description .......................................................................................................................................... 7
8      TEST SUMMARY ........................................................................................................................................................... 8
9      MEASUREMENT UNCERTAINTY ................................................................................................................................... 9
10          MEASUREMENTS, EXAMINATION AND DERIVED RESULTS .................................................................................. 10
     10.1       Radiated Spurious Emissions below 1GHz ............................................................................................................ 10
     10.2       Radiated Spurious Emissions between 1GHz – 25GHz........................................................................................... 13
ANNEX A. TEST INSTRUMENT ........................................................................................................................................... 16
ANNEX B. SIEMIC ACCREDITATION ................................................................................................................................... 17




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                          Visit us at: www.siemic.com; Follow us at:


                                                            Test report No.    FCC IC_RF_SL19022001-ORB-001
                                                            Page               4 of 18




1   Report Revision History
                                                 Report
               Report No.                                                     Description                Issue Date
                                                 Version
    FCC IC_RF_SL19022001-ORB-001                  None                          Original                 05/24/2019




     775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                         Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.   FCC IC_RF_SL19022001-ORB-001
                                                               Page              5 of 18




 2    Executive Summary

The purpose of this test program was to demonstrate compliance of following product
  Company:                 ORBCOMM Inc.
  Product:                 TripLINK 12LB (CT4000)
  Model No.:               TripLINK 12LB

against the current Stipulated Standards. The specified model product stated above has demonstrated compliance with
the Stipulated Standard listed on 1st page. This test report covers the radiated emissions requirements of the standards
referenced in the report to allow system level approval of the modules in specified Hosts.



 3    Customer information
  Applicant Name                          ORBCOMM Inc.
  Applicant Address                       395 W Passaic Street, Suite 325, Rochelle Park, NJ 07662 USA
  Manufacturer Name                       ORBCOMM Inc.
  Manufacturer Address                    395 W Passaic Street, Suite 325, Rochelle Park, NJ 07662 USA



 4    Test site information

  Lab performing tests                    SIEMIC Laboratories
  Lab Address                             775 Montague Expressway, Milpitas, CA 95035
  FCC Test Site No.                       540430
  IC Test Site No.                        4842D
  VCCI Test Site No.                      A0133


 5    Modification
                  Index                           Item                           Description                    Note
                     -                              -                                 -                          -




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                                 Test report No.      FCC IC_RF_SL19022001-ORB-001
                                                                 Page                 6 of 18




 6     EUT Information
6.1      EUT Description

  Model No.                                 TripLINK 12LB
  Trade Name                                ORBCOMM
  Serial No.                                JTCB819070029
  Input Power                               24VDC
  Date of EUT received                      05/01/2019



6.2     Spec for LoRaWan Radio
            Radio Type                                                         LoRaWan
        Operating Frequency                                                 903.0-914.2MHz

             Modulation                                                             Lora

          Channel Spacing                                                          1.6MHz
           Antenna Type                                                      PCB Antenna
        Antenna Gain (Peak)                                                        0.5 dBi
       Antenna Connector Type                                                       N/A



                  Type                            Channel No.                          Frequency (MHz)
                                                      0                                     903.0
      LoRaWAN 125 KHz Bandwidth                       4                                     909.4
                                                      7                                     914.2


6.3      EUT test modes/configuration Description

                 Mode                                                              Note
               LoRaWAN                                                     Continous transmission




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                              Visit us at: www.siemic.com; Follow us at:


                                                                  Test report No.    FCC IC_RF_SL19022001-ORB-001
                                                                  Page               7 of 18




7     Supporting Equipment/Software and cabling Description
7.1       Supporting Equipment

                 Supporting Equipment
    Item                                            Model                   Serial Number            Manufacturer          Note
                     Description
      1                 Laptop            PP01L Latitude E5440                F1WPF12                     Dell                 -




7.2       Cabling Description

                             Connection Start                Connection Stop             Length / shielding Info
          Name                                                                                                           Note
                           From          I/O Port           To         I/O Port         Length (m)       Shielding
                                                                                                                           -



7.3       Test Software Description

    Test Item                           Software                                             Description
 Spurious emission                      TeraTerm                       Set the EUT to transmit continuously in diferent test mode




           775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                                               Test report No.       FCC IC_RF_SL19022001-ORB-001
                                                                               Page                  8 of 18




 8      Test Summary
DTS Band Requirement
              Test Item                         Test standard                               Test Method/Procedure                           Pass / Fail

                                        FCC          15.247, 15.209        FCC                                                             ☒ Pass
  Radiated Spurious Emissions                                                                       ANSI C63.10:2013
                                          IC      RSS 247, RSS-GEN            IC                                                           ☐ N/A
                          1.   All measurement uncertainties do not take into consideration for all presented test results.
                          2.   The applicant shall ensure frequency stability by showing that an emission is maintained within the band of operation
                               under all normal operating conditions as specified in the user’s manual.
     Remark               3.   Only Radiated Spurious Emission was testing for Host configuration.
                          4.   Conducted measurements for TripLINK 12LB are in the following reports:
                               RHF76-052 Module (FCC lD: 2AJUZ76052) Report No: BL-SZ16A0433-602
                               RHF76-052DM Module (IC: 22005-76052) Report No.: CQASZ20190300179E-02




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                      Visit us at: www.siemic.com; Follow us at:


                                                                  Test report No.      FCC IC_RF_SL19022001-ORB-001
                                                                  Page                 9 of 18




9     Measurement Uncertainty

                                                           Emissions

            Test Item                  Frequency Range                               Description                             Uncertainty
                                                              Confidence level of approximately 95% (in the case where
     AC Conducted Emissions             150KHz – 30MHz                                                                         ±3.5dB
                                                                 distributions are normal), with a coverage factor of 2
                                                              Confidence level of approximately 95% (in the case where
    RF conducted measurement            150KHz – 40GHz                                                                        ±0.95dB
                                                                 distributions are normal), with a coverage factor of 2
                                                              Confidence level of approximately 95% (in the case where
    Radiated Spurious Emissions          30MHz – 1GHz          distributions are normal), with a coverage factor of 2 (for      ±6dB
                                                                             EUTs < 0.5m X 0.5m X 0.5m)
                                                              Confidence level of approximately 95% (in the case where
    Radiated Spurious Emissions          1GHz – 40GHz          distributions are normal), with a coverage factor of 2 (for      ±6dB
                                                                             EUTs < 0.5m X 0.5m X 0.5m)




        775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                               Visit us at: www.siemic.com; Follow us at:


                                                                      Test report No.      FCC IC_RF_SL19022001-ORB-001
                                                                      Page                 10 of 18




 10 Measurements, Examination and Derived Results
 10.1 Radiated Spurious Emissions below 1GHz
Requirement(s):

 Spec                   Item   Requirement                                                                                Applicable
                               Except higher limit as specified elsewhere in other section, the emissions from the
                               low-power radio-frequency devices shall not exceed the field strength levels
                               specified in the following table and the level of any unwanted emissions shall not
                               exceed the level of the fundamental emission. The tighter limit applies at the band
 47CFR§15.247(d)               edges                                                                                            ☒
                         a)
   RSS247 (5.5)                          Frequency range (MHz)                          Field Strength (uV/m)
                                                 30 – 88                                         100
                                                88 – 216                                         150
                                                216 960                                          200
                                               Above 960                                         500




     Test Setup




                        1.        The EUT was switched on and allowed to warm up to its normal operating condition.
                        2.        The test was carried out at the selected frequency points obtained from the EUT characterisation.
                                  Maximization of the emissions, was carried out by rotating the EUT, changing the antenna
                                  polarization, and adjusting the antenna height in the following manner:
                                  a.         Vertical or horizontal polarisation (whichever gave the higher emission level over a full
     Procedure                               rotation of the EUT) was chosen.
                                  b.         The EUT was then rotated to the direction that gave the maximum emission.
                                  c.         Finally, the antenna height was adjusted to the height that gave the maximum emission.
                        3.        A Quasi-peak measurement was then made for that frequency point.
                        4.        Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points were
                                  measured.
                        The EUT was scanned up to 1GHz. Both horizontal and vertical polarities were investigated. The results
        Remark
                        show only the worst case.
        Result          ☒ Pass            ☐ Fail


Test Data      ☒ Yes (See below)            ☐ N/A

Test Plot      ☒ Yes (See below)            ☐ N/A
Test was done by Gary Chou at 10m chamber.



            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                    Test report No.   FCC IC_RF_SL19022001-ORB-001
                                                                    Page              11 of 18


Radiated Emission Test Results (Below 1GHz)


            Test specification             Below 1GHz
                                           Temp (°C):                                                   22
     Environmental Conditions:             Humidity (%)                                                47.5
                                           Atmospheric (mbar):                                         1020
             Mains Power:                  12V DC                                                                    Result      Pass
              Tested by:                   Gary Chou
              Test Date:                   05/20/2019
              Remarks:                     Middle Channel




Frequency       Raw        Cable         AF        Level      Measurement                        Azt      Limit    Margin     Pass
                                                                                Pol   Hgt cm
   MHz          dBuV       Loss          dB       dBuV/m         Type                            Deg     dBuV/m     dB        /Fail

  48.01         51.78      11.43       -25.42      37.79       Quasi Max         V     101       262          40     -2.22    Pass
 530.99          35.4      14.46       -17.82      32.04       Quasi Max         H     116       86           46   -13.96     Pass
 711.63         27.89      15.19       -15.14      27.95       Quasi Max         H     110       211          46   -18.05     Pass
 120.16         44.54      12.07       -22.58      34.02       Quasi Max         V     102       103      43.5       -9.48    Pass
 599.98          38.4      14.69       -16.53      36.56       Quasi Max         H     130       163          46     -9.44    Pass
 191.99         46.11      12.54       -24.92      33.73       Quasi Max         H     190       86       43.5       -9.77    Pass




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                    Test report No.     FCC IC_RF_SL19022001-ORB-001
                                                                    Page                12 of 18




            Test specification              Below 1GHz
                                            Temp (°C):                                                   22
      Environmental Conditions:             Humidity (%)                                                47.5
                                            Atmospheric (mbar):                                        1020
             Mains Power:                   12V DC                                                                     Result      Pass
              Tested by:                    Gary Chou
              Test Date:                    05/20/2019
              Remarks:                      Test results for Simultaneous Transmission with Lora, GSM, and BT




Frequency      Raw       Cable       AF        Level     Measurement                               Azt    Limit   Margin        Pass
                                                                           Pol    Hgt cm
   MHz         dBuV      Loss        dB       dBuV/m        Type                                   Deg   dBuV/m    dB           /Fail

  47.82        46.88     11.43     -25.31       33        Quasi Max        V          194          156     40          -7       Pass
 120.18        46.09     12.07     -22.58      35.57      Quasi Max        V          101          260    43.5    -7.93         Pass
 191.44        32.24     12.54     -25.01      19.77      Quasi Max        H          263          172    43.5    -23.73        Pass
 599.98        38.25     14.69     -16.53      36.41      Quasi Max        H          101          148     46     -9.59         Pass
 908.58        23.99     15.92     -12.79      27.13      Quasi Max        V          340          22      46     -18.87        Pass
 623.99        36.01     14.58     -16.55      34.04      Quasi Max        H          148          149     46     -11.96        Pass




          775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                 Visit us at: www.siemic.com; Follow us at:


                                                                          Test report No.    FCC IC_RF_SL19022001-ORB-001
                                                                          Page               13 of 18




   10.2 Radiated Spurious Emissions between 1GHz – 25GHz
  Requirement(s):
Spec                        Item          Requirement                                                                           Applicable
                                          For non-restricted band, In any 100 kHz bandwidth outside the frequency band in
                                          which the spread spectrum or digitally modulated intentional radiator is operating,
                                          the radio frequency power that is produced by the intentional radiator shall be at
                                          least 20 dB or 30dB below that in the 100 kHz bandwidth within the band that                 ☒
                                 a)
                                          contains the highest level of the desired power, determined by the measurement
  47CFR§15.247(d),                        method on output power to be used. Attenuation below the general limits
    RSS247(A8.5)                          specified in § 15.209(a) is not required
                                           ☐ 20 dB down           ☒ 30 dB down
                                          or restricted band, emission must also comply with the radiated emission limits
                                 b)                                                                                                    ☒
                                          specified in 15.209




       Test Setup




                            1.            The EUT was switched on and allowed to warm up to its normal operating condition.
                            2.            The test was carried out at the selected frequency points obtained from the EUT characterisation.
                                          Maximization of the emissions, was carried out by rotating the EUT, changing the antenna polarization,
                                          and adjusting the antenna height in the following manner:
                                          a.        Vertical or horizontal polarisation (whichever gave the higher emission level over a full
       Procedure                                    rotation of the EUT) was chosen.
                                          b.        The EUT was then rotated to the direction that gave the maximum emission.
                                          c.        Finally, the antenna height was adjusted to the height that gave the maximum emission.
                            3.            An average measurement was then made for that frequency point.
                            4.            Steps 2 and 3 were repeated for the next frequency point, until all selected frequency points were
                                          measured.

                            The EUT was scanned up to 25GHz. Both horizontal and vertical polarities were investigated. The results
        Remark
                            show only the worst case.

         Result             ☒ Pass                ☐ Fail

  Test Data       ☒ Yes (See below)              ☐ N/A

  Test Plot       ☐ Yes (See below)             ☒ N/A
  Test was done by Gary Chou at 10m chamber.


              775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                      Visit us at: www.siemic.com; Follow us at:


                                                                     Test report No.     FCC IC_RF_SL19022001-ORB-001
                                                                     Page                14 of 18




Radiated Emission Test Results (Above 1GHz)

             Test specification             Above 1GHz
                                            Temp (°C):                                                       22
      Environmental Conditions:             Humidity (%)                                                    47.5
                                            Atmospheric (mbar):                                             1020
               Mains Power:                 12V DC                                                                      Result      Pass
                Tested by:                  Gary Chou
                Test Date:                  05/21/2018
                Remarks:                    -


 Low channel
Frequency       Raw     Factor          Level                                Pol        Hgt          Azt      Limit    Margin    Pass
                                                     Measurement Type
  (MHz)        (dBuV)   (dB)          (dBuV/m)                              (V/H)      (cm)         (Deg)   (dBuV/m)    (dB)     /Fail

8119.42        47.23      4.64          51.87             Peak Max             H       180          266       74       -22.13    Pass
1944.159       47.51     -0.07          47.44             Peak Max             V       151           61       74       -26.56    Pass
3293.971       42.35      1.09          43.44             Peak Max             H       134          116       74       -30.56    Pass
8119.42        34.12      4.64          38.76           Average Max            H       180          266       54       -15.24    Pass
1944.154       30.32     -0.07          30.25           Average Max            V       151           61       54       -23.75    Pass
3293.977       30.23      1.09          31.32           Average Max            H       134          116       54       -22.68    Pass

Middle channel
Frequency       Raw     Factor          Level                                Pol        Hgt          Azt      Limit    Margin    Pass
                                                     Measurement Type
  (MHz)        (dBuV)   (dB)          (dBuV/m)                              (V/H)      (cm)         (Deg)   (dBuV/m)    (dB)     /Fail

 8170.5        47.14      4.66           51.8             Peak Max             H       180          266       74       -22.2     Pass
1944.156       47.13     -0.07          47.06             Peak Max             V       151           61       74       -26.94    Pass
3293.916       42.46      1.09          43.55             Peak Max             H       134          116       74       -30.45    Pass
8170.19        34.45      4.66          39.11           Average Max            H       180          266       54       -14.89    Pass
1944.126       30.28     -0.07          30.21           Average Max            V       151           61       54       -23.79    Pass
3293.946       30.61      1.09           31.7           Average Max            H       134          116       54       -22.3     Pass

High channel
Frequency       Raw     Factor          Level                                Pol        Hgt          Azt      Limit    Margin    Pass
                                                     Measurement Type
  (MHz)        (dBuV)   (dB)          (dBuV/m)                              (V/H)      (cm)         (Deg)   (dBuV/m)    (dB)     /Fail

8227.84        47.41      4.63          52.04             Peak Max             H       180          266       74       -21.96    Pass
1944.163       47.26     -0.07          47.19             Peak Max             V       151           61       74       -26.81    Pass
3293.942       42.65      1.09          43.74             Peak Max             H       134          116       74       -30.26    Pass
8227.73        34.34      4.64          38.98           Average Max            H       180          266       54       -15.02    Pass
1944.161       30.23     -0.07          30.16           Average Max            V       151           61       54       -23.84    Pass
3293.984       30.41      1.09           31.5           Average Max            H       134          116       54       -22.5     Pass

Note: The testing was based on highest power setting.




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                  Visit us at: www.siemic.com; Follow us at:


                                                                     Test report No.     FCC IC_RF_SL19022001-ORB-001
                                                                     Page                15 of 18



             Test specification             Above 1GHz
                                            Temp (°C):                                                   22
      Environmental Conditions:             Humidity (%)                                                47.5
                                            Atmospheric (mbar):                                        1020
               Mains Power:                 12V DC                                                                      Result      Pass
                Tested by:                  Gary Chou
                Test Date:                  05/20/2019
                Remarks:                    Test results for Simultaneous Transmission with Lora, GSM, and BT




Middle channel
Frequency       Raw     Factor          Level                                Pol        Hgt          Azt      Limit    Margin    Pass
                                                     Measurement Type
  (MHz)        (dBuV)   (dB)          (dBuV/m)                              (V/H)      (cm)         (Deg)   (dBuV/m)    (dB)     /Fail

 8170.2        47.18      4.66          51.84             Peak Max             H       180          266       74       -22.16    Pass
1944.153       47.17     -0.07           47.1             Peak Max             V       151           61       74       -26.9     Pass
3293.975       42.42      1.09          43.51             Peak Max             H       134          116       74       -30.49    Pass
 8170.2        34.53      4.66          39.19           Average Max            H       180          266       54       -14.81    Pass
1944.153       30.24     -0.07          30.17           Average Max            V       151           61       54       -23.83    Pass
3293.975       30.67      1.09          31.76           Average Max            H       134          116       54       -22.24    Pass




            775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                                  Visit us at: www.siemic.com; Follow us at:


                                                               Test report No.      FCC IC_RF_SL19022001-ORB-001
                                                               Page                 16 of 18




Annex A. TEST INSTRUMENT

           Instrument                     Model             Serial #             Cal Date      Cal Cycle    Cal Due     In use

      Radiated Emissions
                                         N9030B
    50GHz Spectrum Analyzer                              MY57140374          01/25/2019         1 Year     01/25/2020
                                          (PXA)
  Bi-Log antenna (30MHz~2GHz)              JB1             A030702           03/09/2018         2 Year     03/09/2020

     Horn Antenna (1-18GHz)                3115            10SL0059          01/26/2018         2 Year     01/26/2020

 RF Pre-Amplifier (9kHz - 6.5GHz)        LPA-6-30          11170601          07/23/2018         1 Year     07/23/2019
    Pre-Amplifier (1-26.5GHz)             8449B           3008A00715         05/16/2019         1 Year     05/16/2020




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                            Visit us at: www.siemic.com; Follow us at:


                                                                Test report No.     FCC IC_RF_SL19022001-ORB-001
                                                                Page                17 of 18




Annex B. SIEMIC Accreditation

        Accreditations         Document                                        Scope / Remark

ISO 17025 (A2LA)                           Please see the documents for the detailed scope

ISO Guide 65 (A2LA)                        Please see the documents for the detailed scope

TCB Designation                            A1, A2, A3, A4, B1, B2, B3, B4, C

FCC DoC Accreditation                      FCC Declaration of Conformity Accreditation

FCC Site Registration                      3 meter site

FCC Site Registration                      10 meter site

IC Site Registration                       3 meter site

IC Site Registration                       10 meter site

                                           Radio & Telecommunications Terminal Equipment:
                                           EN45001 – EN ISO/IEC 17025
EU NB
                                           Electromagnetic Compatibility:
                                           EN45001 – EN ISO/IEC 17025

Singapore iDA
                                           Phase I, Phase II
CB(Certification Body)

Vietnam MIC
                                           Please see the document for the detailed scope
CAB Accreditation

                                           (Phase II) OFCA Foreign Certification Body for Radio and Telecom
Hong Kong OFCA
                                           (Phase I) Conformity Assessment Body for Radio and Telecom

                                           Radio: Scope A – All Radio Standard Specification in Category I
Industry Canada CAB
                                           Telecom: CS-03 Part I, II, V, VI, VII, VIII




         775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:


                                                                 Test report No.   FCC IC_RF_SL19022001-ORB-001
                                                                 Page              18 of 18




                                            Radio: A1. Terminal equipment for purpose of calling
Japan Recognized Certification
                                            Telecom: B1. Specified radio equipment specified in Article 38-2, Paragraph 1, Item
Body Designation
                                            1 of the Radio Law

                                            EMI: KCC Notice 2008-39, RRL Notice 2008-3: CA Procedures for EMI
                                            KN22: Test Method for EMI
                                            EMS: KCC Notice 2008-38, RRL Notice 2008-4: CA Procedures for EMS
                                            KN24, KN61000-4-2, -4-3, -4-4, -4-5, -4-6, -4-8, -4-11: Test Method for EMS

Korea CAB Accreditation                     Radio: RRL Notice 2008-26, RRL Notice 2008-2, RRL Notice 2008-10,
                                            RRL Notice 2007-49, RRL Notice 2007-20, RRL Notice 2007-21, RRL Notice 2007-
                                            80, RRL Notice 2004-68

                                            Telecom: President Notice 20664, RRL Notice 2007-30, RRL Notice 2008-7 with
                                            attachments 1, 3, 5, 6; President Notice 20664, RRL Notice 2008-7 with attachment 4

                                            LP0002, PSTN01, ADSL01, ID0002, IS6100, CNS14336, PLMN07, PLMN01,
Taiwan NCC CAB Recognition
                                            PLMN08

Taiwan BSMI CAB Recognition                 CNS 13438

                                            R-3083: Radiation 3 meter site
Japan VCCI                                  C-3421: Main Ports Conducted Interference Measurement
                                            T-1597: Telecommunication Ports Conducted Interference Measurement

                                            EMC: AS/NZS CISPR 11, AS/NZS CISPR 14.1, AS/NZS CISPR22, AS/NZS
                                            61000.6.3, AS/NZS 61000.6.4

                                            Radio communications: AS/NZS 4281, AS/NZS 4268, AS/NZS 4280.1,
                                            AS/NZS 4280.2, AS/NZS 4295, AS/NZS 4582, AS/NZS 4583, AS/NZS 4769.1,
Australia CAB Recognition
                                            AS/NZS 4769.2, AS/NZS 4770, AS/NZS 4771

                                            Telecommunications: AS/ACIF S002:05, AS/ACIF S003:06, AS/ACIF S004:06
                                            AS/ACIF S006:01, AS/ACIF S016:01, AS/ACIF S031:01, AS/ACIF S038:01,
                                            AS/ACIF S040:01, AS/ACIF S041:05, AS/ACIF S043.2:06, AS/ACIF S60950.1

                                            AS/ACIF S002, AS/ACIF S003, AS/ACIF S004, AS/ACIF S006, AS/ACIF
Australia NATA Recognition                  S016,AS/ACIF S031, AS/ACIF S038, AS/ACIF S040, AS/ACIF S041, AS/ACIF
                                            S043.2




       775 Montague Expressway, Milpitas, CA 95035, USA • Phone: (+1) 408 526 1188 • Facsimile (+1) 408 526 1088

                             Visit us at: www.siemic.com; Follow us at:



Document Created: 2019-07-01 08:13:17
Document Modified: 2019-07-01 08:13:17

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC