FCC PARTS 2 & 90, SUBPART I, NON-BROADCAST RADIO TRANSCEIVERS                                                                          Page 8
VRS, Model 270-3240-020                                                                                                    FCC ID: XEU2703240




5.5.        RF EXPOSURE REQUIREMENTS [§§ 1.1310 & 2.1091]
5.5.1.          Limits
§ 1.1310: The criteria listed in the following table shall be used to evaluate the environmental impact of human
exposure to radio-frequency (RF) radiation as specified in 1.1307(b).

                                             LIMITS FOR MAXIMUM PERMISSIBLE EXPOSURE (MPE)
     Frequency                 Electric Field              Magnetic Field Strength              Power Density (mW/cm2)      Average Time
       Range                   Strength (V/m)                      (A/m)                                                      (minutes)
        (MHz)
                                             (A) Limits for Occupational/Control Exposures
       30-300                         61.4                             0.163                                  1.0                   6
     300-1500                           --                                --                                 f/300                  6
                                   (B) Limits for General Population/Uncontrolled Exposure
       30-300                         27.5                             0.073                                  0.2                   30
   300-1500                 --                                            --                                f/1500                  30
Note: f is frequency in MHz

5.5.2.          Method of Measurements

Calculation Method of RF Safety Distance:

                   PG         EIRP
           S=              =
                  4π ⋅ r 2
                             4π ⋅ r 2

           Where,                P: power input to the antenna in mW
                                 EIRP: Equivalent (effective) isotropic radiated power.
                                 S: power density mW/cm2
                                 G: numeric gain of antenna relative to isotropic radiator
                                 r: distance to centre of radiation in cm



                     PG             EIRP
           r=              =
                    4π ⋅ S          4π ⋅ S

           FCC radio frequency exposure limits may be exceeded at distances closer than r cm from the antenna of
           this device.




ULTRATECH GROUP OF LABS                                                                                                     File #: ETST-005F90
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                              January 4, 2010
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)


FCC PARTS 2 & 90, SUBPART I, NON-BROADCAST RADIO TRANSCEIVERS                                                                          Page 9
VRS, Model 270-3240-020                                                                                                    FCC ID: XEU2703240



5.5.3.          Evaluation of RF Exposure Compliance Requirements

Maximum RF Power conducted, Pconducted[dBm] = 33.19 at 769.5 MHz
Maximum Antenna Gain, G[dBi] = 3
Maximum EIRP, PEIRP[dBm] = 36.19


MPE Limit for Occupational/Controlled Exposure, Scontrolled[mW/cm2] = 769.5/300 = 2.57
MPE Limit for General Population/Uncontrolled Exposure, Suncontrolled[mW/cm2] = 769.5/1500 = 0.51


Calculated RF Safety Distance for Occupational/Controlled Exposure, rsafety_controlled[cm] = 11.36
Calculated RF Safety Distance for General Population/Uncontrolled Exposure, rsafety_uncontrolled[cm] = 25.40




ULTRATECH GROUP OF LABS                                                                                                     File #: ETST-005F90
3000 Bristol Circle, Oakville, Ontario, Canada L6H 6G4                                                                              January 4, 2010
Tel. #: 905-829-1570, Fax. #: 905-829-8050, Email: vic@ultratech-labs.com, Website: http://www.ultratech-labs.com

All test results contained in this engineering test report are traceable to National Institute of Standards and Technology (NIST)



Document Created: 2010-01-07 14:14:10
Document Modified: 2010-01-07 14:14:10

© 2024 FCC.report
This site is not affiliated with or endorsed by the FCC