Test reports

FCC ID: XBD-BT43ISC

Test Report

Download: PDF
FCCID_4282685

                                    Test Report

                                    FCC ID: XBD-BT43ISC


                                    Date of issue: Apr. 15, 2019



     Report Number:                                  MTi190411E063


     Sample Description:                             BluStreamFM


     Model(s):                                       BT43IS Rev C, BTHFS430 Rev C


     Applicant:                                      AAMP of Florida, Inc. dba AAMP Global


     Address:                                        15500 Lightwave Dr. Suite 202 Clearwater,
                                                     Florida 33760 United States


     Date of Test:                                   Mar. 29, 2019 – Apr. 15, 2019




                                        Shenzhen Microtest Co., Ltd.
                                          http://www.mtitest.com




This test report is valid for the tested samples only. It cannot be reproduced except in full without prior written consent of Shenzhen
Microtest Co., Ltd.

Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
 Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                                             - Page 2 of 20 -                                        Report No.: MTi190411E063


                                                                    Table of Contents

1       GENERAL DESCRIPTION ..................................................................................................................................... 4
    1.1     DESCRIPTIONS OF EUT ............................................................................................................................................... 4
    1.2     FREQUENCY CHANNEL UNDER TEST .............................................................................................................................. 4
    1.3     ANCILLARY EQUIPMENT LIST......................................................................................................................................... 4
    1.4     DESCRIPTION OF SUPPORT UNITS ................................................................................................................................. 4
2       SUMMARY OF TEST RESULTS ............................................................................................................................. 6
3       TEST FACILITIES AND ACCREDITATIONS .............................................................................................................. 7
    3.1     TEST LABORATORY...................................................................................................................................................... 7
    3.2     ENVIRONMENTAL CONDITIONS ..................................................................................................................................... 7
    3.3     MEASUREMENT UNCERTAINTY...................................................................................................................................... 7
    3.4     TEST SOFTWARE ........................................................................................................................................................ 7
4       EQUIPMENT LIST ............................................................................................................................................... 8
5       TEST RESULT ...................................................................................................................................................... 9
    5.1 ANTENNA REQUIREMENT ............................................................................................................................................ 9
       5.1.1   Standard requirement ................................................................................................................................. 9
       5.1.2   EUT antenna description ............................................................................................................................. 9
    5.2 AC POWER LINE CONDUCTED EMISSION....................................................................................................................... 10
       5.2.1   Limit .......................................................................................................................................................... 10
       5.2.2   Test method .............................................................................................................................................. 10
       5.2.3   Test Result ................................................................................................................................................. 10
    5.3 FIELD STRENGTH OF FUNDAMENTAL AND HARMONIC EMISSIONS ...................................................................................... 11
       5.3.1   Limits ......................................................................................................................................................... 11
       5.3.2   Test Method .............................................................................................................................................. 11
       5.3.3   Test Result ................................................................................................................................................. 12
    5.4 OPERATING FREQUENCY& OCCUPIED BANDWIDTH ....................................................................................................... 13
       5.4.1   Limits ......................................................................................................................................................... 13
       5.4.2   Test method .............................................................................................................................................. 13
       5.4.3   Test result.................................................................................................................................................. 13
    5.5 RADIATED EMISSION ................................................................................................................................................ 14
       5.5.1   Limit .......................................................................................................................................................... 14
       5.5.2   Test method .............................................................................................................................................. 14
       5.5.3   Test Result ................................................................................................................................................. 14
PHOTOGRAPHS OF THE TEST SETUP ...........................................................................................................................19
PHOTOGRAPHS OF THE EUT .......................................................................................................................................20




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 3 of 20 -                       Report No.: MTi190411E063


                              Test Result Certification

Applicant’s name:                 AAMP of Florida, Inc. dba AAMP Global


Address:                          15500 Lightwave Dr. Suite 202 Clearwater, Florida 33760 United States


Manufacture's name:               Skytech creations limited

                                  Unit 507, 5/F., IC Development Centre, No.6 Science Park West
Address:                          Avenue, Shatin, Hong Kong


Product name:                     BluStreamFM


Trademark:                        iSimple


Model name:                       BT43IS Rev C, BTHFS430 Rev C


Standards:                        FCC Part 15.239

                                  ANSI C63.10-2013
Test Procedure:                   DA 00-705

This device described above has been tested by Shenzhen Microtest Co., Ltd. and the test results show that
the equipment under test (EUT) compliance with the FCC requirements. And it is applicable only to the tested
sample identified in the report.



                  Tested by:


                                                               Demi Mu                              Apr. 15, 2019


                 Reviewed by:


                                                               Blue Zheng                           Apr. 15, 2019

               Approved by:

                                                               Smith Chen                           Apr. 15, 2019




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 4 of 20 -                       Report No.: MTi190411E063


1 General description
1.1 Descriptions of EUT

    Product name:                         BluStreamFM

    Model name:                           BT43IS Rev C

    Series model:                         BTHFS430 Rev C
                                          All models are the same circuit and RF module, except for the
    Difference of series model:
                                          model No..
    Tx/Rx frequency range:                88.1 MHz to 107.9 MHz

    Modulation type:                      FM

    Power source:                         DC 12V by battery

    Adapter information:                  N/A

    Antenna designation:                  PCB antenna (Antenna Gain: 0dBi)

    Hardware version:                     V0.6

    Software version:                     V0.3



1.2 199 channels are provided to FM

                                                      Channel List
                               Frequency                           Frequency                             Frequency
          Channel                           Channel                                    Channel
                                 (MHz)                               (MHz)                                 (MHz)
               1                  88.1        100                     98.0                198              107.8
               2                  88.2        101                     98.1                199              107.9
               k              88.1+0.1(k-1)    --                        --

1.3 Frequency Channel Under Test
                            Channel                                                    Frequency
                               Low                                                      88.1MHz
                             Middle                                                     98.1MHz
                              High                                                      107.9MHz

1.4 Ancillary equipment list
           Equipment                         Model                            S/N                    Manufacturer
              Battery                            /                             /                             /

1.5 Description of Support Units
The EUT has been tested as an independent unit together with other necessary accessories or


Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 5 of 20 -                       Report No.: MTi190411E063

support units. The following support units or accessories were used to form a representative test
configuration during the tests.

     Item      Equipment                Brand                     Model/Type No.             Series No.          Note
        /                 /                        /                         /                       /
        /                 /                        /                         /                       /
Note:
  (1)The support equipment was authorized by Declaration of Confirmation.
  (2)For detachable type I/O cable should be specified the length in cm in『Length』column.




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 6 of 20 -                       Report No.: MTi190411E063


2 Summary of Test Results
Test procedures according to the technical standards:

      Item        FCC Part No.                   Description of Test                      Result               Remark

        1              15.203                  Antenna requirement                         Pass
                                            AC power line conducted
        2              15.207                                                              Pass
                                                     emission
                                          Field strength of fundamental
        3            15.239 (b)                                                            Pass
                                            and harmonic emissions
        4              15.209                    Radiated emission                         Pass

        5            15.239 (a)                 Operating frequency                        Pass

        6            15.239 (a)                 Occupied Bandwidth                         Pass

    The meaning of symbols: “N/A” – Not Applicable




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 7 of 20 -                       Report No.: MTi190411E063


3 Test Facilities and Accreditations
3.1 Test laboratory
     Test Laboratory                   Shenzhen Microtest Co., Ltd
                                       No.102A & 302A, East Block, Hengfang Industrial Park,
     Location                          Xingye Road, Xixiang, Bao'an District, Shenzhen,
                                       Guangdong, China
     FCC Registration
                                       448573
     No.:

3.2 Environmental conditions
     Temperature:                      15ºC~35ºC
     Humidity                          20%~75%
     Atmospheric
                                       98kPa~101kPa
     pressure

3.3 Measurement uncertainty
The reported uncertainty of measurement y ± U,where expended uncertainty U is based on
a standard uncertainty multiplied by a coverage factor of k=2,providing a level of
confidence of approximately 95 %
     RF frequency                                                1 x 10-7
     RF power, conducted                                         ±1.38dB
     Conducted emission(150kHz~30MHz)                            ±0.21dB
     Radiated emission(30MHz~1GHz)                               ±4.68dB
     Radiated emission (above 1GHz)                              ±4.89dB
     Temperature                                                 ±0.5°C
     Humidity                                                    ±2%

3.4 Test software

         Software
                                     Manufacturer                            Model                            Version
          Name
      RF Test System                       Farad                              LZ-RF                          Lz_Rf 3A3




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                         - Page 8 of 20 -                      Report No.: MTi190411E063


4 Equipment list
Equipmen             Equipment             Manufactur                                           Calibratio
                                                               Model          Serial No.                          Due date
  t No.                Name                   er                                                 n date
                       Spectrum
  MTI-E001                                     Agilent         E4407B        MY41441082          2018/09/18       2019/09/17
                       Analyzer
                                           Rohde&schw
  MTI-E004        EMI Test Receiver                              ESPI           1000314          2018/09/18       2019/09/17
                                               arz
                      Broadband                               VULB916
  MTI-E006                                 schwarabeck                             872           2018/09/18       2019/09/17
                       antenna                                   3
                                                              BBHA912
  MTI-E007           Horn antenna          schwarabeck                            1201           2018/09/18       2019/09/17
                                                                0D
  MTI-E014              amplifier             America           8447D         3113A06150         2018/09/18       2019/09/17
                     Conduction
                                                                             126A1343/20
  MTI-E015         Immunity Signal           Schloder         CDG6000                            2018/09/18       2019/09/17
                                                                                 15
                     Generator
                      Coupled
                                                                 CND         A2210332/20
  MTI-E016           decoupling              Schloder                                            2018/09/18       2019/09/17
                                                                M2/M3            15
                      network
  MTI-E034              amplifier              Agilent          8449B         3008A02400         2018/09/18       2019/09/17
                    Artificial power                          NSLK812
  MTI-E037                                 Schwarzbeck                            #841           2018/09/18       2019/09/17
                        network                                  7
                      Spectrum
  MTI-E040                                     Agilent         N9020A        MY49100060          2018/09/18       2019/09/17
                       analyzer
  MTI-E041         Signal generator            Agilent         N5182A        MY49060455          2018/09/18       2019/09/17
                     Analog signal
  MTI-E042                                     Agilent         E4421B        GB40051240          2018/09/18       2019/09/17
                      generator
                                                Dare          RPR3006         16I00054SN
  MTI-E043           Power probe                                                                 2018/09/18       2019/09/17
                                            Instruments         W                 O16
  MTI-E047         10dB attenuator         Mini-Circuits      UNAT-10+           15542           2018/09/18       2019/09/17
                       spectrum            Rohde&schw
  MTI-E049                                                     FSP-38            100019          2018/09/18       2019/09/17
                       analyzer                arz
                     PSG Signal
  MTI-E050                                     Agilent         E8257D        MY46520873          2018/09/18       2019/09/17
                      generator
                     Active Loop
                                                                FMZB
  MTI-E061          Antenna 9kHz -         Schwarzbeek                           00044           2018/09/18       2019/09/17
                                                                1519 B
                        30MHz
                                             Chengdu
                       18-40GHz                               ZLNA-18-
  MTI-E052                                  step Micro                          1608001          2018/09/18       2019/09/17
                        amplifier                              40G-21
                                            Technology
                                                       BBHA917      BBHA91705
  MTI-E053         15-40G Antenna          Schwarzbeek                             2018/09/18 2019/09/17
                                                           0            82
                  Artificial power                     NSLK812
  MTI-E058                             Schwarzbeck                     #841        2018/09/18 2019/09/17
                      network                              7
Note: the calibration interval of the above test instruments is 12 months and the calibrations are traceable to
international system unit (SI).




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 9 of 20 -                       Report No.: MTi190411E063


5 Test Result
5.1 Antenna requirement
5.1.1      Standard requirement
15.203 requirement: For intentional device, according to 15.203: an intentional radiator shall be
designed to ensure that no antenna other than that furnished by the responsible party shall be used
with the device
5.1.2      EUT antenna description
The EUT antenna is PCB antenna (0dBi). It comply with the standard requirement. In case of
replacement of broken antenna the same antenna type must be used.




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 10 of 20 -                      Report No.: MTi190411E063

5.2 AC power line conducted emission
5.2.1      Limit

                          Frequency                                                        Limit
                            (MHz)                                      Quasi-peak                       Average
                            0.15-0.5                                      66 to 56                      56 to 46
                              0.5-5                                          56                             46
                              5-30                                           60                             50

Note: Decreases with the logarithm of the frequency from 0.15MHz to 0.5MHz.
5.2.2      Test method
1. The EUT was placed 0.8 meters from the horizontal ground plane with EUT being connected to
the power mains through a line impedance stabilization network (LISN). All other support equipment
powered from additional LISN(s). The LISN provide 50 Ohm/50uH of coupling impedance for the
measuring instrument.
2. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and
forth in the center forming a bundle 30 to 40 cm long.
3. I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the
cable may be terminated, if required, using the correct terminating impedance. The overall length
shall not exceed 1 m.
4. LISN is at least 80 cm from nearest part of EUT chassis.
5. The resolution bandwidth of EMI test receiver is set at 9kHz.
5.2.3      Test Result
Note: the device is battery powered, so this item is not available.




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 11 of 20 -                      Report No.: MTi190411E063



5.3 Field strength of fundamental and harmonic emissions
5.3.1      Limits
§15.239 (b): The field strength of any emissions within the permitted 200 kHz band shall not exceed
250 microvolts/meter at 3 meters. The emission limit in this paragraph is based on measurement
instrumentation employing an average detector. The provisions in §15.35 for limiting peak
emissions apply.


5.3.2      Test Method
1. The EUT is placed on a turntable, which is 0.8m above ground plane for test frequency range
blew 1GHz, and 1.5m above ground plane for test frequency range above 1GHz.
2. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out the
highest emissions.
3. Use the following spectrum analyzer settings:
         Span = wide enough to fully capture the emission being measured
         RBW = 1 MHz for f ≥ 1GHz
         RBW = 100 kHz for f < 1 GHz
         VBW ≥ RBW
         Sweep = Auto
         Detector function = Peak
         Trace = max hold
4. Follow the guidelines in ANSI C63.4-2014 with respect to maximizing the emission by rotating the
EUT, adjusting the measurement antenna height and polarization, etc. The peak reading of the
emission, after being corrected by the antenna factor, cable loss, pre-amp gain, etc., is the peak
field strength, submit this data. Each emission was to be maximized by changing the polarization of
receiving antenna both horizontal and vertical.
5. The peak level, once corrected, must comply with the limit specified in Section 15.209. Set the
spectrum to
      RBW = 1MHz
      VBW = 10Hz
      Detector = PK for AV value, while maintaining all of the other instrument settings




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 12 of 20 -                      Report No.: MTi190411E063

5.3.3      Test Result

   Field Strength of Fundamental Emissions and Field strength of spurious emissions Value

                                    Field
 Operating Frequency                                                  Limit @3m           Margin
                                   Strength           Detector                                                 Antenna
        (MHz)                                                          (dBuV/m)            (dB)
                                  (dBuV/m)
                                    41.13               QP               67.96             26.83              Vertical
            88.1
                                    21.71             Average            47.96             26.25             Horizontal
                                    43.29               QP               67.96             24.67              Vertical
            98.1
                                    21.46             Average            47.96             26.50             Horizontal
                                    42.31               QP               67.96             25.65              Vertical
           107.9
                                     20.8             Average            47.96             27.16             Horizontal

Note: If the PK measured values lower than average mode limit, the EUT shall be deemed to meet
average limits and then no additional average mode measurement performed.




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 13 of 20 -                      Report No.: MTi190411E063

5.4 Operating frequency& Occupied Bandwidth
5.4.1      Limits
   §15.239 (a): Emissions from the intentional radiator shall be confined within a band 200 kHz wide
   centered on the operating frequency. The 200 kHz band shall lie wholly within the frequency
   range of 88-108 MHz.
5.4.2      Test method
        Use the following spectrum analyzer settings:
            Span = approximately 2 to 3 times the 20 dB bandwidth, centered on a hopping channel
            RBW ≥1% of the 20 dB bandwidth
            VBW ≥RBW
            Sweep = auto
            Detector function = peak
            Trace = max hold
The EUT should be transmitting at its maximum data rate. Allow the trace to stabilize. Use the
marker-to-peak function to set the marker to the peak of the emission. Use the marker-delta
function to measure 20 dB down one side of the emission. Reset the marker-delta function, and
move the marker to the other side of the emission, until it is (as close as possible to) even with the
reference marker level. The marker-delta reading at this point is the 20 dB bandwidth and 99%
occupied bandwidth of the emission.


5.4.3      Test result

     Permitted range of operating frequencies
       FL (KHz)
                          FH(kHz)                  Limit (MHz)                                            Result
         (kHz)
       88.0658           107.9342             FL≥88            FH≤108                                       Pass

                                              20dBm emission bandwidth                                Limit
            Frequency (MHz)
                                                      (KHz)                                          (KHz)
                     88.1                             68.25                                           200
                     98.1                                   68.31                                     200
                    107.9                                   68.43                                     200




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 14 of 20 -                      Report No.: MTi190411E063

5.5 Radiated emission
5.5.1      Limit
Emissions radiated outside of the specified frequency bands, except for harmonic emissions,
(b)shall be attenuated by at least 50 dB below the level of the fundamental emissions or to the
general field strength limits listed in RSS-Gen, whichever is less stringent.
                                                  Field               Field
                Frequency                                                                                Measurement
                                                strength            strength            Detector
                  (MHz)                                                                                    distance
                                                 μV/m               dBμV/m
                    30-88                          100                 40                   QP
                    88-216                         150                 43.5                 QP
                   216-960                         200                  46                  QP
                                                                                                                3m
                   960-1000                        500                  54                  QP
               Above 1000                          500                  54                  AV
               Above 1000                         5000                  74                  PK

5.5.2      Test method
1. The EUT is placed on a turntable, which is 0.8m above ground plane for test frequency range
blew 1GHz, and 1.5m above ground plane for test frequency range above 1GHz.
2. EUT is set 3m away from the receiving antenna, which is varied from 1m to 4m to find out the
highest emissions.
3. Use the following spectrum analyzer settings:
      Span = wide enough to fully capture the emission being measured
      RBW = 1 MHz for f ≥ 1GHz
      100 kHz for f < 1 GHz, VBW ≥ RBW
      Sweep = auto
      Detector function = peak
      Trace = max hold
4. Follow the guidelines in ANSI C63.4-2014 with respect to maximizing the emission by rotating the
EUT, adjusting the measurement antenna height and polarization, etc. The peak reading of the
emission, after being corrected by the antenna factor, cable loss, pre-amp gain, etc., is the peak
field strength, submit this data. Each emission was to be maximized by changing the polarization of
receiving antenna both horizontal and vertical.
5. The peak level, once corrected, must comply with the limit specified in Section 15.209. Set the
RBW = 1MHz, VBW = 10Hz, Detector = PK for AV value, while maintaining all of the other
instrument settings.
5.5.3      Test Result
Remark:
If the PK measured values lower than average mode limit, the EUT shall be deemed to meet
average limits and then no additional average mode measurement performed.




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 15 of 20 -                      Report No.: MTi190411E063


Radiated emission
Between 30MHz – 1GHz
Note: All the modulation modes have been tested, and the worst result was report as below:
  EUT:                    BluStreamFM                              Model Name :               BT43IS Rev C
  Relative
                          52%                                      Phase:                     H
  Humidity:
  Pressure:               1010 hPa                                 Test Voltage :             DC 12V from battery
  Test Mode :             TX (98.1MHz)




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 16 of 20 -                      Report No.: MTi190411E063



  EUT:                    BluStreamFM                              Model Name :               BT43IS Rev C
  Relative
                          52%                                      Phase:                     V
  Humidity:
  Pressure:               1010 hPa                                 Test Voltage :             DC 12V from battery
  Test Mode :             TX (98.1MHz)




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 17 of 20 -                      Report No.: MTi190411E063




ABOVE 1GHz
 EUT:                     BluStreamFM                              Model Name :               BT43IS Rev C
 Relative
                          52%                                      Phase:                     H
 Humidity:
 Pressure:                1010 hPa                                 Test Voltage :             DC 12V from battery
 Test Mode :              TX (98.1MHz)




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 18 of 20 -                      Report No.: MTi190411E063



  EUT:                    BluStreamFM                              Model Name :               BT43IS Rev C
  Relative
                          52%                                      Phase:                     V
  Humidity:
  Pressure:               1010 hPa                                 Test Voltage :             DC 12V from battery
  Test Mode :             TX (98.1MHz)




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 19 of 20 -                      Report No.: MTi190411E063

PHOTOGRAPHS OF THE TEST SETUP
                                                   Radiated emission




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China


                                                        - Page 20 of 20 -                      Report No.: MTi190411E063




PHOTOGRAPHS OF THE EUT
See the APPENDIX 1: EUT PHOTO in the report No.: MTi190411E062-1.



                                              ----END OF REPORT----




Tel:(86-755)88850135        Fax: (86-755) 88850136                  Web: http://www.mtitest.com           E-mail: mti@51mti.com
Address: No.102A & 302A, East Block, Hengfang Industrial Park, Xingye Road, Xixiang, Bao'an District, Shenzhen, Guangdong, China



Document Created: 2019-05-14 16:34:59
Document Modified: 2019-05-14 16:34:59

© 2025 FCC.report