Test report

FCC ID: XAYW2500

Test Report

Download: PDF
FCCID_1168314

                                                                                                 6 Randolph Way
               Advanced                                                                   Hillsborough, NJ 08844
                                                                                                Tel: (908) 927 9288
               Compliance Laboratory                                                           Fax: (908) 927 0728



   ELECTROMAGNETIC EMISSION COMPLIANCE REPORT
                                                     of
                                              MODULE
                                 MODEL: CCA-SA-W2500-02
                                   FCC ID: XAYW2500
                                           July 23, 2009

    This report concerns (check one): Original grant                  x        Class II change
    Equipment type: Low Power Intentional Radiator


    Deferred grant requested per 47 CF 0.457(d)(1)(ii)?     yes            no    x
                                     If yes, defer until:                      (date)
    Company agrees to notify the Commission by                                 (date)
    of the intended date of announcement of the product so that the grant can be
    issued on that date.


    Transition Rules Request per 15.37?                     yes            no    x
    If no, assumed Part 15, Subpart B for unintentional radiators - the new 47 CFR
    [10-1-90 Edition] provision.


    Report prepared for:                            TELEGRID TECHNOLOGIES, INC.
    Report prepared by:                             Advanced Compliance Lab
    Report number:                                  0048-090708-01



Lab Code: 200101   The test result in this report IS supported and covered by the NVLAP accreditation


                                                                                                                  FCC ID: XAYW2500




Table of Contents

Report Cover Page .................................................................................................... 1

Table of Contents ...................................................................................................... 2

Figures ....................................................................................................................... 3


1. GENERAL INFORMATION ............................................................................... 4
      1.1 Verification of Compliance ...................................................................... 4
      1.2 Equipment Modifications ........................................................................ 5
      1.3 Product Information ................................................................................ 6
      1.4 Test Methodology..................................................................................... 6
      1.5 Test Facility .............................................................................................. 6
      1.6 Test Equipment ........................................................................................ 6
      1.7 Statement of the Document Use............................................................... 7

2. PRODUCT LABELING........................................................................................ 8

3. SYSTEM TEST CONFIGURATION................................................................... 10
      3.1 Justification .............................................................................................. 10
      3.2 Special Accessories ................................................................................... 10
      3.3 Configuration of Tested System .............................................................. 10

4. SYSTEM SCHEMATICS ..................................................................................... 13

5. RADIATED EMISSION DATA ........................................................................... 14
      5.1 Field Strength Calculation....................................................................... 14
      5.2 Test Methods and Conditions.................................................................. 14
      5.3 Test Data .................................................................................................. 14

6. EUT RECEIVING MODE VERIFICATION ...................................................... 17

7. PHOTOS OF TESTED EUT................................................................................. 18




———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844                       Tel: (908) 927-9288 Fax: (908) 927-0728



                                                                        2


                                                                                                        FCC ID: XAYW2500




                                                            Figures

Figure 2.1 FCC ID Label........................................................................................... 8

Figure 2.2 Location of Label on Back of the EUT.................................................... 8

Figure 2.3 Proposed FCC Labeling Information of EUT’s Hosting Device ............ 9

Figure 3.1 Radiated Test Setup, Position 1 .............................................................. 11

Figure 3.2 Radiated Test Setup, Position 2 .............................................................. 11

Figure 3.3 Radiated Test Setup, Position 3 .............................................................. 12

Figure 4.1 EUT Schematics....................................................................................... 13

Figure 7.1 Front View ............................................................................................... 19

Figure 7.2 Back View ................................................................................................ 20

Figure 7.3 Open Top View ........................................................................................ 21

Figure 7.4 Open Bottom View................................................................................... 22




———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844                Tel: (908) 927-9288 Fax: (908) 927-0728



                                                                  3


                                                                                            FCC ID: XAYW2500




1. GENERAL INFORMATION
1.1 Verification of Compliance

                  EUT:               TELETAG

                Model:               CCA-SA-W2500-02

             Applicant:              TELEGRID Technologies, Inc.

            Test Type:               FCC Part 15C CERTIFICATION

                Result:              PASS

            Tested by:               ADVANCED COMPLIANCE LABORATORY

            Test Date:               July 10-15, 2009

      Report Number:                 0048-090708-01

The above equipment was tested by Compliance Laboratory, Advanced Technologies, Inc. for
compliance with the requirement set forth in the FCC rules and regulations Part 15 subpart C. This
said equipment in the configuration described in the report, shows the maximum emission levels
emanating from equipment are within the compliance requirements.

The estimated uncertainty of the test result is given as following. The method of uncertainty
calculation is provided in Advanced Compliance Lab. Doc. No. 0048-01-01.

                                    Prob. Dist.   Uncertainty(dB)      Uncertainty(dB)         Uncertainty(dB)
                                                   30-1000MHz            1-6.5GHz                Conducted
Combined Std. Uncertainty uc          norm.           ±2.36                  ±2.99                  ±1.83




____________________
Wei Li                                                                                   Date: July 23, 2009
Lab Manager
Advanced Compliance Lab




———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844     Tel: (908) 927-9288 Fax: (908) 927-0728



                                                        4


                                                                                          FCC ID: XAYW2500




1.2 Equipment Modifications



N/A




———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844   Tel: (908) 927-9288 Fax: (908) 927-0728



                                                        5


                                                                                             FCC ID: XAYW2500




1.3 Product Information


                                           System Configuration

        ITEM                    DESCRIPTION                           FCC ID                            CABLE
        Product          TELETAG CCA-SA-W2500-                    XAYW2500
                         02 (1)
      Housing            PLASTICS
    Power Supply         3V DC Battery
   Operation Freq.       2.4GHz
      Receiver           CCA-SA-W2500-02(RX)                      Verification

(1) EUT submitted for grant.


1.4 Test Methodology

Radiated tests were performed according to the procedures in ANSI C63.4 at an antenna to EUT
distance of 3 meters.

1.5 Test Facility

The open area test site and conducted measurement facility used to collect the radiated and
conducted data are located at Hillsborough, New Jersey. This site has been accepted by FCC to
perform measurements under Part 15 or 18 in a letter dated May 19, 1997 (Refer to: 31040/PRV
1300F2). The NVLAP Lab code for accreditation of FCC EMC Test Method is: 200101-0.

1.6 Test Equipment

 Manufacture         Model        Serial No.                  Description                       Last Cal          Cal
                                                                                               dd/mm/yy           Due
                                                                                                               dd/mm/yy
Hewlett-Packard     HP8546A      3625A00341                  EMI Receiver                       25/09/08        25/09/09
    EMCO              3115           4945          Double Ridge Guide Horn Antenna              02/12/08        02/12/09
    EMCO             3104C        9307-4396         20-300MHz Biconical Antenna                 02/09/08        02/09/09
    EMCO              3146        9008-2860       200-1000MHz Log-Periodic Antenna              11/08/08        11/08/09
Fischer Custom       LISN-2       900-4-0008         Line Impedance Stabilization               23/08/08        23/08/09
                                                              Networks
Fischer Custom      LISN-2        900-4-0009         Line Impedance Stabilization               23/08/08       23/08/09
                                                              Networks

All Test Equipment Used are Calibrated Traceable to NIST Standards.

———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844      Tel: (908) 927-9288 Fax: (908) 927-0728



                                                        6


                                                                                          FCC ID: XAYW2500




1.7 Statement for the Document Use

This report shall not be reproduced except in full, without the written approval of the laboratory.
And this report must not be used by the client to claim product endorsement by NVLAP or any
agency of the U.S. Government.




———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844   Tel: (908) 927-9288 Fax: (908) 927-0728



                                                        7


                                                                                          FCC ID: XAYW2500




2. PRODUCT LABELING

                        TELEGRID     CCA-SA-W2500-02
                        FCC ID: XAYW2500
                                      Figure 2.1 FCC ID Label
                    This device complies with part 15 of
                    the FCC Rules. Operating is subject to
                    the following two conditions: (1) This
                    Figure 2.2 Location of Label on the Side of EUT
                    device    may not cause harmful
                    interference, and (2) this device must
                    accept any interference received,
                    including interference that may cause
                    undesired operation.


                                  Figure 2.1 FCC ID Label
                                 (Only FCC ID shown on EUT)




                                            FCC
                                            Label




                                     Figure 2.2 FCC Label Location




———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844   Tel: (908) 927-9288 Fax: (908) 927-0728



                                                        8


                                                                                          FCC ID: XAYW2500




               Contains FCC ID: XAYW2500


               This device complies with FCC Part 15C
               Rules. Operating is subject to the following
               two conditions: (1) This device may not
               cause harmful interference, and (2) this
               device must accept any interference
               received, including interference that may
               cause undesired operation.
                   Hosting Device Back




                                                             ID Label




          Figure 2.3 Proposed FCC ID Label & Location for MODULE Host Device
            (The statement may be shown in its user manual for small size devices )




———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844   Tel: (908) 927-9288 Fax: (908) 927-0728



                                                        9


                                                                                          FCC ID: XAYW2500




3. SYSTEM TEST CONFIGURATION
3.1 Justification

The system was configured for testing in a typical fashion (as a customer would normally use it).
And its antenna was permanently attached to the EUT.
Testing was performed as EUT was continuously operated at the following frequency channels:
2.42575GHz.

Fresh external battery was used for extended operating time.



3.2 Special Accessories

N/A

3.3 Configuration of Tested System

Figure 3.1 to Figure 3.3 illustrate this system, which is tested standing along.




———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844   Tel: (908) 927-9288 Fax: (908) 927-0728



                                                       10


                                                                                          FCC ID: XAYW2500




                           Figure 3.1 Radiated Test Setup, position 1




                           Figure 3.2 Radiated Test Setup, position 2

———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844   Tel: (908) 927-9288 Fax: (908) 927-0728



                                                       11


                                                                                          FCC ID: XAYW2500




                           Figure 3.3 Radiated Test Setup, position 3




———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844   Tel: (908) 927-9288 Fax: (908) 927-0728



                                                       12


                                                                                          FCC ID: XAYW2500




4. SYSTEM SCHEMATICS



                                              See Attachment.

                                      Figure 4.1 System Schematics




———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844   Tel: (908) 927-9288 Fax: (908) 927-0728



                                                       13


                                                                                          FCC ID: XAYW2500




5. RADIATED EMISSION DATA

5.1 Field Strength Calculation
The corrected field strength is automatically calculated by EMI Receiver using following:
                                  FS = RA +AF + CF + AG

where FS: Corrected Field Strength in dBµV/m
      RA: Amplitude of EMI Receiver before correction in dBµV
      AF: Antenna Factor in dB/m
      CF: Cable Attenuation Factor in dB
      AG: Built-in Preamplifier Gain in dB (Stored in receiver as part of the calibration data)

THE “DUTY CYCLE CORRECTION FACTOR” FOR SPURIOUS RADIATED EMISSIONS IS;
20 log * (1 ms / 100 ms) = -40 dB, WHICH WAS USED TO CORRECT THE AVERAGE RADIATED
EMISSION READINGS.

5.2 Test Methods and Conditions

The initial step in collecting radiated data is a EMI Receiver scan of the measurement range below
30MHz using peak detector and 9KHz IF bandwidth / 30KHz video bandwidth. For the range
30MHz - 1GHz, 120KHz IF bandwidth / 120KHz video bandwidth are used. Both bandwidths are
1MHz for above 1GHz measurement. Up to 10th harmonics were investigated.

5.3 Test Data

The following data lists the significant emission frequencies, polarity and position, peak reading of
the EMI Receiver, the FCC limit, and the difference between the peak reading and the limit.
Explanation of the correction and calculation are given in section 5.1.


Test Personnel:        David Tu


Typed/Printed Name: David Tu                                         Date:      July 23, 2009




———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844   Tel: (908) 927-9288 Fax: (908) 927-0728



                                                       14


                                                                                             FCC ID: XAYW2500




                                 Radiated Test Data (CH-2425.75MHz)
                                                                                   Average FCC 3m              Peak
                                               Peak   Average FCC 3m
Frequency Polarity Antenna Azimuth                                                  Differ- Peak               Differ-
                                              Reading Reading Average
                                                                                    ence    Limit              ence
               (V,H)     Height                 at 3m       After       Limit
                                                           Correc-
             Position                             (2)                     (1)
                                                            tion
                                                                                              (dBuV/m
   (MHz)      (X,Y,Z)      (m)     (Degree) (dBuV/m) (dBuV/m) (dBuV/m)
                                                                                                  )
  2425.75       V/X       1.25       270        87.9            47.9      94            -46.1 114                 -26.1
  4851.50       V/X        1.3       250        43.5             3.5      54            -50.5    74               -30.5
  7277.25       V/X        1.2       220        48.0               8      54              -46    74                 -26
  2425.75       H/X       1.45        90        101.0             61      94              -33 114                   -13
  4851.50       H/X        1.4       100        49.5             9.5      54            -44.5    74               -24.5
  7277.25       H/X        1.4       100        50.0              10      54              -44    74                 -24

  2425.75       V/Y        1.2       180         90.9           50.9      94            -43.1     114             -23.1
  4851.50       V/Y        1.3       180         46.5            6.5      54            -47.5     74              -27.5
  7277.25       V/Y        1.3       200         48.4            8.4      54            -45.6     74              -25.6
  2425.75       H/Y        1.5        90         95.6           55.6      94            -38.4     114             -18.4
  4851.50       H/Y        1.4        80         52.0             12      54              -42     74                -22
  7277.25       H/Y        1.5        80         50.4           10.4      54            -43.6     74              -23.6

  2425.75        V/Z         1.2        180       94.9              54.9     94           -39.1 114             -19.1
  4851.50        V/Z         1.3        170       48.9               8.9     54           -45.1    74           -25.1
  7277.25        V/Z         1.2        180       50.2              10.2     54           -43.8    74           -23.8
  2425.75        H/Z         1.3         90       96.1              56.1     94           -37.9 114             -17.9
  4851.50        H/Z        1.25        270       50.1              10.1     54           -43.9    74           -23.9
  7277.25        H/Z         1.3        120       49.4               9.4     54           -44.6    74           -24.6
(1) The limit for emissions within the 2400-2483.5MHz band is 50mV(94dB) per Sec. 15.249. The limit for its
harmonics is 500uV (54dB). Other spurious emissions shall be lower than either its fundamental by 50dB or the limit
defined in Sec. 15.209, whichever is higher.
(2) If each peak reading is less than the FCC average limit, it’ll be not necessary to show the measured/ calculated
average reading.
                      Other Spurious outside of the band 2400-2483.5MHz
No other significant spurious emissions were founded for outside of the band 2400-2483.5MHz. i.e.
Comparing to the limit defined in Sec. 15.209, emissions below the limit by 20dB were not recorded.




———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844      Tel: (908) 927-9288 Fax: (908) 927-0728



                                                         15


                                                                                                                    FCC ID: XAYW2500




                                                                             * RBW 100 kHz       Delta 1 [T1 ]
                                                                              VBW 300 kHz                   -1.28 dB
                               Ref    0 dBm             * Att    10 dB        SWT 2.5 ms            848.000000000 kHz

                               0                                                                 Marker 1 [T1 ]
                                                                                                           -53.23 dBm
                                                                                                      2.425381695 GHz   B
                               -10

                    1 PK
                    VIEW
                               -20



                               -30



                               -40
                                                                                                                        PRN

                               -50                       1
                                                                                                  1
                                        D1 -53.34 dBm
                                                                                                                        3DB
                               -60



                               -70



                               -80



                               -90


                               -100

                               Center 2.425749695 GHz                200 kHz/                              Span 2 MHz



                    Date:              10.JUL.2009    15:06:59




                                                         20dB Bandwidth Plot

                                                                              RBW 100 kHz         Delta 1 [T1 ]
                                                                              VBW 300 kHz                     2.82 dB
                          Ref        0 dBm             * Att     10 dB        SWT 5 ms                    1.010000 ms

                           0                                                                      Marker 1 [T1 ]
                                                                                                            -36.60 dBm
                                                                                                          2.410000 ms         B
                           -10

                  1 PK
                  VIEW
                           -20



                           -30                                                               1
                                                                         1

                           -40
                                                                                                                            PRN

                           -50

                                                                                                                            3DB
                           -60



                           -70



                           -80



                           -90


                           -100

                          Center 2.425749695 GHz                         500 µs/



                  Date:              10.JUL.2009     15:03:13




                                                                Duty Cycle Plot




———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844                        Tel: (908) 927-9288 Fax: (908) 927-0728



                                                                         16


                                                                                          FCC ID: XAYW2500




6. EUT RECEIVING MODE VERIFICATION

Radiated Test Data for Receiving Mode (worst case: Z-position)
                                                    Peak
Frequency       Polarity    Antenna Azimuth                 FCC 3m            Difference
                                                  Reading
                             Height               at 3m(2)  Limit(1)
   (MHz)        (H or V)      (m)       (Degree) (dBuV/m) (dBuV/m)             (dBuV/m)
     78            V           1.2         90          24.3    40                   -15.7
    157            V           1.2        100          29.0   43.5                  -14.5
    208            H          1.4         260          23.6    46                   -22.4
    520            H          1.3         270          21.4    46                   -24.6

(1) Receiving mode spurious emissions shall be lower than the limit defined in Sec. 15.209.
(2) If each peak reading is less than the FCC average limit, it’ll be not necessary to show the
measured/ calculated average reading.




———————————————————————————————————————————————
Advanced Compliance Lab, 6 Randolph Way, Hillsborough, NJ 08844   Tel: (908) 927-9288 Fax: (908) 927-0728